Chapter 4 Management - 1

4.1 【iMonitor】

4.1.1 Create User

Create users who can log in to this project and manage the devices they can operate based on the set permissions.

Chapter 4 Management - 2

Chapter 4 Management - 3

Item

Describe

iAccess User

Number of existing users and maximum number of user accounts.

Name

Set the user’s name.

Nickname

Set the user’s nickname.

Title

Set the user’s title.

Account(Email)

Set the user’s login account.

Mobile Phone Number

Set the user’s mobile phone number.

Password

Set the user’s login password.

Email Language

Set the language for receiving emails for this user

Description

Set the description about the user.

Data (Enable/Disable)

Set the user’s permissions for operating the Dataitem Group.

Black List (Enable/Disable)

Forbid the user to log in to the IOT management page

4.1.2 Create Devices

Click on “Device” in the bottom left corner, then click on “Add” in the top right corner.

Chapter 4 Management - 4

Chapter 4 Management - 5

Item

Describe

Name

Customize the device name.

Product Type

Select the device type.

Service Password

Set the service password to match the one entered on the device.

Hardware ID

Enter the hardware ID displayed on the device.

Description

Set any additional notes.

Link Device

Set up the links that will be used; functionality will not be affected if this section is left unset.

Third Party App Information Broadcast

Set whether to send notifications for this device to Third Party App.

After creating the device, you need to switch it to “Enable” before you can use it.

Chapter 4 Management - 6

4.1.3 Create Dataitems

After creating the device, you can add Dataitems.

Chapter 4 Management - 7

Chapter 4 Management - 8

Item

Describe

read-write

Set whether this Dataitem can be written to; if not switched, it can only be read.

Select Device

Select the device to get data.

Dataitem Name

Set Dataitem name.

Data Format

The format set here must match the components on the HMI.

Bit

16Bit-BCD

16Bit-INT

16Bit-UINT

16Bit-HEX

32Bit-BCD

32Bit-INT

32Bit-UINT

32Bit-HEX

32Bit-FLOAT

ASCII String

Length

Data length.

Decimal Point Location

Set the decimal point display position.

Max / Min

Set the range of numerical input.

Comment

Set related remarks.

Address

Set the address to read from.

HMI

Please copy and paste from FvDesigner to here. If the address entered here is different from the one on the HMI, it will not be able to read.

Example: $U:V0, @0:R0, $T:Tag0

PLC

Directly enter the PLC’s addresses.

Example:M0,D1,R100

Update Mode

Mode for device to return data.

Period

According to [Period Time] to return data periodically.

Trigger

Return data when the value has changed.

Period Time

Use in the periodic update mode, increase the time can reduce the network bandwidth usage and reduce the system loading.

DataLog Enable/Disable

Enable the data log function.

Sampling Period

Period of data log sampling.

Alarm Enable/Disable

Enable alarm function.

Alarm Condition

When the condition to trigger an alarm is met, the alarm will be sent.

Alarm Content

User customize the alarm content to be sent.

Send Email

Send message via email.

App Notifications

Push notification of the alarm message to mobile APP.

Send SMS Message*Note 1

Send message via SMS message.

The third party

When this Dataitem triggers an alarm, the selected personnel will be notified synchronously.

Alarm Contact

Receiver of the alarm message.

Recurrence Interval (Minutes)

*Note 2

When alarm is triggered and send the first SMS, e-mail or push notification, this is used to determine the interval to send the message again until the alarm is cleared.

Transfer Delay Time (Second)

When the alarm condition is triggered, this is used to determine delay how many times to send SMS, e-mail or APP push notification. This function is to avoid sending too much message when the value changed in a limited time.

Note 1: Purchasing SMS credits is required for sending text messages.

Note 2: When the resend interval is set to “0” minutes, alarm notifications will only be sent once and will stop resend.

4.1.4 Create Dataitem Group

You must set up a Dataitem Group before you can read or write from the Web or App. Place the Dataitem you want to monitor in the same Group.

Chapter 4 Management - 9

Chapter 4 Management - 10

Item

Describe

Dataitem Group Name

Set Group name.

Upload

Set the group icon.

GPS Source

Set the group GPS source. The coordinates need to be set in FvDesigner.

Description

Set your own description.

Add Device

To add devices to the group, the right-side arrow provides the drop-down menu for users to add dataitems into the group.

User

Add users who can monitor this group.

4.1.5 Create Trend

Select Dataitems from the created group to display trend chart lines.

Chapter 4 Management - 11

Chapter 4 Management - 12

Item

Describe

Trend Name

Set the trend name.

Y-axis Unit

Set the Y-axis unit.

Select Dataitem Group

Add groups to the trend and select the group’s dataitem.

4.2 【iAccess】

4.2.1 Create User

Create users who can log in to this project and manage the devices they can operate based on the set permissions.

Chapter 4 Management - 13

Chapter 4 Management - 14

Item

Describe

iAccess User

Number of existing users and maximum number of user accounts.

Name

Set the user’s name.

Nickname

Set the user’s nickname.

Title

Set the user’s title.

Account (Email)

Set the user’s login account.

Mobile Phone Number

Set the user’s mobile phone number.

Password

Set the user’s login password.

Email Language

Set the language for receiving emails for this user

Description

Set the description about the user.

Data (Enable/Disable)

Set the user’s permissions for operating the Device Group.

Black List (Enable/Disable)

Disable the user from logging into the IOT page.

Dataitem

Set whether the user can read and write Dataitems.

Maintain

Set whether the user can use maintenance functions such as Upload, Download, Pass Through, and File Transfer.

Viewer

Set whether the user can use the screen monitoring function of iAccess Viewer.

4.2.2 Create Devices

Click on “Device” in the bottom left corner, then click on “Add” in the top right corner.

Chapter 4 Management - 15

Chapter 4 Management - 16

Item

Describe

Name

Customize the device name.

Product Type

Select the device type.

Service Password

Set the service password to match the one entered on the device.

Hardware ID

Enter the hardware ID displayed on the device.

Description

Set any additional notes.

Link Device

Set up the links that will be used; functionality will not be affected if this section is left unset.

Third Party App Information Broadcast

Set whether to send notifications for this device to Third Party App.

After creating the device, you need to switch it to “Enable” before you can use it.

Chapter 4 Management - 17

4.2.3 Create Dataitems

After creating the device, you can add Dataitems.

Chapter 4 Management - 18

Chapter 4 Management - 19

Item

Describe

read-write

Set whether this Dataitem can be written to; if not switched, it can only be read.

Select Device

Select the device to get data.

Dataitem Name

Set Dataitem name.

Data Format

The format set here must match the components on the HMI.

Bit

16Bit-BCD

16Bit-INT

16Bit-UINT

16Bit-HEX

32Bit-BCD

32Bit-INT

32Bit-UINT

32Bit-HEX

32Bit-FLOAT

ASCII String

Length

Data length.

Decimal Point Location

Set the decimal point display position.

Max / Min

Set the range of numerical input.

Comment

Set related remarks.

Address

Set the address to read from.

HMI

Please copy and paste from FvDesigner to here. If the address entered here is different from the one on the HMI, it will not be able to read.

Example: $U:V0, @0:R0, $T:Tag0

PLC

Directly enter the PLC’s addresses.

Example:M0,D1,R100

Update Mode

Mode for device to return data.

Period

According to [Period Time] to return data periodically.

Trigger

Return data when the value has changed.

Period Time

Use in the periodic update mode, increase the time can reduce the network bandwidth usage and reduce the system loading.

4.2.4 Create Dataitem Group

You must set up a group before you can read or write data items on the Web or App. Place the Devices you want to view in the same group.

Chapter 4 Management - 20

Chapter 4 Management - 21

Item

Describe

Dataitem Group Name

Set Group name.

Upload

Set the group icon.

GPS Source

Set the group GPS source. The coordinates need to be set in FvDesigner.

Description

Set your own description.

Add Device

To add devices to the group, the right-side arrow provides the drop-down menu for users to add dataitems into the group.

User

Add users who can monitor this group.

4.2.5 Connect Log

View the usage status of the device.

Chapter 4 Management - 22

Was this page helpful?