All registers in this chapter can only be written using the MOV function or the := operator in ST. The register values will be reset to 0 when EtherCAT communication is stopped.

Set Current Coordinates

Number TAG Name definition Illustrate
M10630 SET_CUR_COOR Set current coordinates 1. When it is triggered, the value of DR37050 is set to the current coordinates
2. It can only be used when the axis is not in control or synchronization mode
DR37050 SET_COOR_VALUE the coordinates value 1. The unit and decimal place are as defined in the axis table.
2. Triggering M10630 sets DR37050 to the current coordinate.

Advanced Mode

Control bits

Number TAG Name definition Illustrate
M10631 ADV_MODE_ON Axis advanced mode on High: On
Low: Off
M10632 ADV_MODE_UNIT_PLS advanced mode units High: Pulse unit
Low: Axis table unit
M10633 ADV_MODE_COOR_ABS_OR_REF_MASK advanced mode coordinates High: Absolute coordinates
Low: Relative coordinates
M11268 IS_ADV_ACT Advanced mode in action High: In advanced control mode
M11269 IS_ADV_DN Advanced mode done High: Advanced control mode done

Parameters (set by fun. MOV or the := operator)

Number TAG Name definition Illustrate
DR37052 SET_ADV_MODE Choose advanced control mode 1: position control
2: speed control
3: torque control
(Set to 0 before change control mode)
DR37054 SET_ADV_CMD parameter Commands when running advanced control mode
DR37056 SET_ADV_CMD2 parameter 2 Parameter when running advanced control mode
DR37058 SET_ADV_CMD3 parameter 3 Parameter when running advanced control mode
DR37060 SET_ADV_CMD4 parameter 4 Parameter when running advanced control mode

Position mode (mode 1)

Number TAG Name definition Illustrate
DR37052 SET_ADV_MODE control mode 1: position control
2: speed control
3: torque control
(Set to 0 before change control mode)
DR37054 SET_ADV_CMD Control Target In mode 1, 2, unit follow the unit switch relay
In mode 3, unit is 0.1%
DR37056 SET_ADV_CMD2 Max Vel In mode 1, unit follow the unit switch relay
In mode 2, means torque limit (unit: 0.1%)
In mode 3, means max speed (unit: RPM)
DR37058 SET_ADV_CMD3 Max Acc In mode 1, unit follow the unit switch relay Decimal place in axis table
DR37060 SET_ADV_CMD4 Max Dec In mode 1, unit follow the unit switch relay Decimal place in axis table Use Max Acc value when Max Dec is 0

Velocity mode (mode 2)

Number TAG Name definition Illustrate
DR37052 SET_ADV_MODE control mode 1: position control
2: speed control
3: torque control
(Set to 0 before change control mode)
DR37054 SET_ADV_CMD Control Target In mode 1, 2, unit follow the unit switch relay
In mode 3, unit is 0.1%
DR37056 SET_ADV_CMD2 Max Torque In mode 1, unit follow the unit switch relay
In mode 2, means torque limit (unit: 0.1%)
In mode 3, means max speed (unit: RPM)
DR37058 SET_ADV_CMD3 Max Acc
DR37060 SET_ADV_CMD4 Max Dec

Torque mode (mode 3)

Number TAG Name definition Illustrate
DR37052 SET_ADV_MODE control mode 1: position control
2: speed control
3: torque control
(Set to 0 before change control mode)
DR37054 SET_ADV_CMD Control Target In mode 1, 2, unit follow the unit switch relay
In mode 3, unit is 0.1%
DR37056 SET_ADV_CMD2 Max Velocity In mode 1, unit follow the unit switch relay In mode 2, means torque limit (unit: 0.1%)
In mode 3, means max speed (unit: RPM)