About SC3 Drive
| Type | Model Name |
| EtherCAT | SC3____00 |
| Pulse | SC3____10 |
Essential Parameters
Basic Setting:
| Number | definition | Illustrate | Type | |
| Pn000 | X X X □ | Direction | 0: CCW 1: CW |
All |
| X X □ X | Control Mode | 0: Speed 1: Pulse 2: Torque C: Point control |
Pulse | |
| Pn002 | X □ X X | Encoder | 0: Abs 1: Inc |
All |
| Pn00B | X □ X X | Power Input | 0: Three Phase 1: Single Phase |
All |
How to Reset Abs Encoder

Break setting
| Number | definition | Illustrate | Type | |
| Pn50F | X □ X X | Break output (/BK) Allocation | 0~5: Out 0 ~ Out 5 6: Disable |
All |
| Pn506 | Break Delay Time | 0 ~ 50 (unit: 10ms) | All |

Essential Setting of EtherCAT Type
| Number | definition | Illustrate | Type | |
| Pn001 | X X □ X | Overtravel (OT) Stopping Method | 1 or 3: can “servo on” when servo is at the position of limit switch | ECAT |
| Pn002 | X X X □ | Torque Limit | 1: From External (EtherCAT) | ECAT |
| X X □ X | Velocity Limit | 1: From External (EtherCAT) | ECAT | |
| Pn20E | Gear Ratio (Numerator) | Set 1:1 to receive full scale of encoder | ECAT |
Example of IO Configuration
| Number | Definition | Illustrate | Type | |
| Pn50A | □ X X X | Positive Limit Switch Input | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
All |
| Pn50B | X X X □ | Negative Limit Switch Input | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
All |
| Pn511 | X X X □ | DOG Limit Switch Input | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
All |
Parameters of Pulse Type
| Number | Definition | Illustrate | Type | |
| Pn200 | X X X □ | Pulse input type | 0 ~ 4: Positive logic 5 ~ 9: Negative logic |
Pulse |
| Pn20E | Gear Ratio (Numerator) | Default value | All | |
| Pn50A | X X □ X | Servo on signal (/SON) | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
Pulse |
Point table control: Pulse Type
| Number | Definition | Illustrate | Type | |
| Pn640 | X X X □ | Start Signal | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
Pulse |
| X X □ X | Step Change Signal | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
Pulse | |
| Pn641 | □□□□ | Step Select signal (4 bits) | 0 ~ 7: IN0 ~ IN7 8: Always inactive 9: Always active |
Pulse |
| Pn7XX | Point table | Pulse |
Other Parameters
| Number | Definition | Illustrate | Type | |
| Pn109 | Feedforward | 0 ~ 100 % | ||
| Pn10A | Feedforward Filter Time Constant | 0 ~ 6400 (unit: 0.01ms) | ||
| Pn511 | X □□ X | Touch probe capture input | 5 ~ 7: IN5 ~ IN7 0 ~ 4: inactive |
ECAT |

Wiring and Settings of Pulse Type
Positioning mode:
| Number | definition | Illustrate | Type | |
| Pn000 | X X □ X | Control Mode | 1: Pulse | |
| Pn200 | X X X □ | Pulse input type | 0: Pulse/ Direction | Pulse |
| Pn50A | X X □ X | Servo on signal (/SON) | 0 ~ 7: IN0 ~ IN7 9: Always active |
Puls e |
The input resistors can be omitted when using pin 28 and pin 29 instead of pin 1 and pin 3.

Velocity and Torque mode:
| Number | definition | Illustrate | Type | |
| Pn000 | X X □ X | Control Mode | 0: Speed 2: Torque |
|
| Pn002 | X X X □ | Torque Limit | 1: From External (Analog input) | |
| X X □ X | Velocity Limit | 1: From External (Analog input) | ||
| Pn50A | X X □ X | Servo on (/SON) |
When the input source is set to external in velocity control mode, both analog inputs (ANA0 and ANA1) can be used for the target velocity and maximum torque.

How to Use Program table in Pulse Type SC3
Parameters
| Number | Definition | Illustrate | Type | |
| Pn000 | X X □ X | Control Mode | C: Point control | Pulse |
| Pn50A | X X □ X | Servo on signal (/SON) | ||
| Pn640 | X X X □ | Start Signal (/PGM-START) | Pulse | |
| X X □ X | Step Change Signal (/PGM-STEP) | Pulse | ||
| Pn641 | □□□□ | Step Select signal (4 bits) | Pulse | |
| Pn7XX | Point table | Pulse |
Point Tables
| Number | Definition | Illustrate | Type | |
| Pn7XX | Point table | 1 Point + 8 | Pulse | |
| Pn700 | X X X □ | Relative/absolute | ||
| Pn701 | Target (unit: Pulse) | -1073747823 ~ 1073747823 | ||
| Pn703 | Speed (unit: 100 Pulse/s) | 0 ~ 65535 | ||
| Pn704 | X X X □ | End Condition | 0 ~ 5 | |
| Pn705 | Wait Time (unit: 1ms) | 1 ~ 65535 | ||
| Pn706 | Loops | 1 ~ 65535 | ||
| Pn707 | Next Step | -1 ~ 15 |
Example
| Number | Definition | Illustrate | Type | |
| Pn50A | X X □ X | Servo on signal (/SON) | ||
| Pn640 | X X X □ | Start Signal (/PGM-START) | Pulse | |
| X X □ X | Step Change Signal (/PGM-STEP) | Pulse | ||
| Pn641 | □□□□ | Step Select signal (4 bits) | Pulse |