Posted in ,

By

2 of 7Updated 2026-11-242 min read中文版

About SC3 Drive

Type Model Name
EtherCAT SC3____00
Pulse SC3____10

Essential Parameters

Basic Setting:

Number definition Illustrate Type
Pn000 X X X □ Direction 0: CCW
1: CW
All
X X □ X Control Mode 0: Speed
1: Pulse
2: Torque
C: Point control
Pulse
Pn002 X □ X X Encoder 0: Abs
1: Inc
All
Pn00B X □ X X Power Input 0: Three Phase
1: Single Phase
All

How to Reset Abs Encoder

Break setting

Number definition Illustrate Type
Pn50F X □ X X Break output (/BK) Allocation 0~5: Out 0 ~ Out 5
6: Disable
All
Pn506 Break Delay Time 0 ~ 50 (unit: 10ms) All

Essential Setting of EtherCAT Type

Number definition Illustrate Type
Pn001 X X □ X Overtravel (OT) Stopping Method 1 or 3: can “servo on” when servo is at the position of limit switch ECAT
Pn002 X X X □ Torque Limit 1: From External (EtherCAT) ECAT
X X □ X Velocity Limit 1: From External (EtherCAT) ECAT
Pn20E Gear Ratio (Numerator) Set 1:1 to receive full scale of encoder ECAT

Example of IO Configuration

Number Definition Illustrate Type
Pn50A □ X X X Positive Limit Switch Input 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
All
Pn50B X X X □ Negative Limit Switch Input 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
All
Pn511 X X X □ DOG Limit Switch Input 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
All

Parameters of Pulse Type

Number Definition Illustrate Type
Pn200 X X X □ Pulse input type 0 ~ 4: Positive logic
5 ~ 9: Negative logic
Pulse
Pn20E Gear Ratio (Numerator) Default value All
Pn50A X X □ X Servo on signal (/SON) 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
Pulse

Point table control: Pulse Type

Number Definition Illustrate Type
Pn640 X X X □ Start Signal 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
Pulse
X X □ X Step Change Signal 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
Pulse
Pn641 □□□□ Step Select signal (4 bits) 0 ~ 7: IN0 ~ IN7
8: Always inactive
9: Always active
Pulse
Pn7XX Point table Pulse

Other Parameters

Number Definition Illustrate Type
Pn109 Feedforward 0 ~ 100 %
Pn10A Feedforward Filter Time Constant 0 ~ 6400 (unit: 0.01ms)
Pn511 X □□ X Touch probe capture input 5 ~ 7: IN5 ~ IN7
0 ~ 4: inactive
ECAT

Wiring and Settings of Pulse Type

Positioning mode:

Number definition Illustrate Type
Pn000 X X □ X Control Mode 1: Pulse
Pn200 X X X □ Pulse input type 0: Pulse/ Direction Pulse
Pn50A X X □ X Servo on signal (/SON) 0 ~ 7: IN0 ~ IN7
9: Always active
Puls
e

The input resistors can be omitted when using pin 28 and pin 29 instead of pin 1 and pin 3.

Velocity and Torque mode:

Number definition Illustrate Type
Pn000 X X □ X Control Mode 0: Speed
2: Torque
Pn002 X X X □ Torque Limit 1: From External (Analog input)
X X □ X Velocity Limit 1: From External (Analog input)
Pn50A X X □ X Servo on (/SON)

When the input source is set to external in velocity control mode, both analog inputs (ANA0 and ANA1) can be used for the target velocity and maximum torque.

How to Use Program table in Pulse Type SC3

Parameters

Number Definition Illustrate Type
Pn000 X X □ X Control Mode C: Point control Pulse
Pn50A X X □ X Servo on signal (/SON)
Pn640 X X X □ Start Signal (/PGM-START) Pulse
X X □ X Step Change Signal (/PGM-STEP) Pulse
Pn641 □□□□ Step Select signal (4 bits) Pulse
Pn7XX Point table Pulse

Point Tables

Number Definition Illustrate Type
Pn7XX Point table 1 Point + 8 Pulse
Pn700 X X X □ Relative/absolute
Pn701 Target (unit: Pulse) -1073747823 ~ 1073747823
Pn703 Speed (unit: 100 Pulse/s) 0 ~ 65535
Pn704 X X X □ End Condition 0 ~ 5
Pn705 Wait Time (unit: 1ms) 1 ~ 65535
Pn706 Loops 1 ~ 65535
Pn707 Next Step -1 ~ 15

Example

Number Definition Illustrate Type
Pn50A X X □ X Servo on signal (/SON)
Pn640 X X X □ Start Signal (/PGM-START) Pulse
X X □ X Step Change Signal (/PGM-STEP) Pulse
Pn641 □□□□ Step Select signal (4 bits) Pulse

Was this page helpful?

Tip: press ← → to switch chapters, Ctrl+K to search