Note
All registers in this chapter can only be written using the MOV function or the := operator in ST. The register values will be reset to 0 when EtherCAT communication is stopped.
Set Current Coordinates
| Number | TAG Name | definition | Illustrate |
| M10630 | SET_CUR_COOR | Set current coordinates | 1. When it is triggered, the value of DR37050 is set to the current coordinates 2. It can only be used when the axis is not in control or synchronization mode |
| DR37050 | SET_COOR_VALUE | the coordinates value | 1. The unit and decimal place are as defined in the axis table. 2. Triggering M10630 sets DR37050 to the current coordinate. |
Advanced Mode

Control bits
| Number | TAG Name | definition | Illustrate |
| M10631 | ADV_MODE_ON | Axis advanced mode on | High: On Low: Off |
| M10632 | ADV_MODE_UNIT_PLS | advanced mode units | High: Pulse unit Low: Axis table unit |
| M10633 | ADV_MODE_COOR_ABS_OR_REF_MASK | advanced mode coordinates | High: Absolute coordinates Low: Relative coordinates |
| M11268 | IS_ADV_ACT | Advanced mode in action | High: In advanced control mode |
| M11269 | IS_ADV_DN | Advanced mode done | High: Advanced control mode done |
Parameters (set by fun. MOV or the := operator)
| Number | TAG Name | definition | Illustrate |
| DR37052 | SET_ADV_MODE | Choose advanced control mode | 1: position control 2: speed control 3: torque control (Set to 0 before change control mode) |
| DR37054 | SET_ADV_CMD | parameter | Commands when running advanced control mode |
| DR37056 | SET_ADV_CMD2 | parameter 2 | Parameter when running advanced control mode |
| DR37058 | SET_ADV_CMD3 | parameter 3 | Parameter when running advanced control mode |
| DR37060 | SET_ADV_CMD4 | parameter 4 | Parameter when running advanced control mode |
Position mode (mode 1)
| Number | TAG Name | definition | Illustrate |
| DR37052 | SET_ADV_MODE | control mode | 1: position control 2: speed control 3: torque control (Set to 0 before change control mode) |
| DR37054 | SET_ADV_CMD | Control Target | In mode 1, 2, unit follow the unit switch relay In mode 3, unit is 0.1% |
| DR37056 | SET_ADV_CMD2 | Max Vel | In mode 1, unit follow the unit switch relay In mode 2, means torque limit (unit: 0.1%) In mode 3, means max speed (unit: RPM) |
| DR37058 | SET_ADV_CMD3 | Max Acc | In mode 1, unit follow the unit switch relay Decimal place in axis table |
| DR37060 | SET_ADV_CMD4 | Max Dec | In mode 1, unit follow the unit switch relay Decimal place in axis table Use Max Acc value when Max Dec is 0 |
Velocity mode (mode 2)
| Number | TAG Name | definition | Illustrate |
| DR37052 | SET_ADV_MODE | control mode | 1: position control 2: speed control 3: torque control (Set to 0 before change control mode) |
| DR37054 | SET_ADV_CMD | Control Target | In mode 1, 2, unit follow the unit switch relay In mode 3, unit is 0.1% |
| DR37056 | SET_ADV_CMD2 | Max Torque | In mode 1, unit follow the unit switch relay In mode 2, means torque limit (unit: 0.1%) In mode 3, means max speed (unit: RPM) |
| DR37058 | SET_ADV_CMD3 | Max Acc | |
| DR37060 | SET_ADV_CMD4 | Max Dec |
Torque mode (mode 3)
| Number | TAG Name | definition | Illustrate |
| DR37052 | SET_ADV_MODE | control mode | 1: position control 2: speed control 3: torque control (Set to 0 before change control mode) |
| DR37054 | SET_ADV_CMD | Control Target | In mode 1, 2, unit follow the unit switch relay In mode 3, unit is 0.1% |
| DR37056 | SET_ADV_CMD2 | Max Velocity | In mode 1, unit follow the unit switch relay In mode 2, means torque limit (unit: 0.1%) In mode 3, means max speed (unit: RPM) |