{"id":3174,"date":"2026-11-17T18:37:46","date_gmt":"2026-11-17T10:37:46","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m01-en-02\/"},"modified":"2026-11-17T18:37:46","modified_gmt":"2026-11-17T10:37:46","slug":"mplc-m01-en-02","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m01-en-02\/","title":{"rendered":"Product Line"},"content":{"rendered":"<p><strong>Product Line<\/strong><\/p>\n<p>FATEK M-Series PLC is designed as a modularized PLC product that is provided with custom-made, flexible expansion and easier adjustment characteristics to realize the most compact PLC in the world market. In this way, it has conglomerated the control, axial control, communication, data collection and IoT functions in a single compact machine unit. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-02\/mplc-m01-en-02-001.png\" \/><\/p>\n<p>M-Series Mainframe Diagram<\/p>\n<h3>2-1 Product Features<\/h3>\n<p>1. \tInter-connection available between modules<\/p>\n<p>Through the connector provided at the lateral side of the module, the modules can be connected with each other as required. Therefore, the system expansion can be realized in the minimum space limit. <\/p>\n<p>2. \tHigher user-friendly for using the newly edited UperLogic program<\/p>\n<p>Through the Type-C available in the commercial market, the CPU module can be easily connected with the UperLogic program installed in the PC. In the meantime, the programming interface is also designed in a terse and orderly manner for easier understanding. <\/p>\n<p>3. \tMultiple built-in functions are provided for the CPU module to reduce the system costs. <\/p>\n<p>The CPU module has been provided with the following built-in functions. It is not required to purchase other modules when used in smaller-sized application environment. <\/p>\n<ul>\n<li>\n<ul>\n<li>Basic input function, control interruption and impulse capture function. <\/li>\n<li>Basic output function<\/li>\n<li>Ethernet function<\/li>\n<li>RS485 function<\/li>\n<li>EtherCAT function (optional)<\/li>\n<li>High-speed counting function<\/li>\n<li>NC positioning control function<\/li>\n<li>AI analog input function (optional)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>4. \tFlexible power source configuration<\/p>\n<p>It can be used with the power module to support an AC220V\/100V power supply. It is also not required to replace the internal battery. <\/p>\n<p>5. \tSupport FATEK micro-SD memory card (it does not support the commercial SD memory card).<\/p>\n<p>The SD memory card slot will be provided for each type of configuration. Through such SD memory card, you will be allowed to use the following functions:<\/p>\n<ul>\n<li>\n<ul>\n<li>Data memory function.<\/li>\n<li>With program data backup and quick restoration functions, you may easily and quickly set up the programs required for several machines. <\/li>\n<li>Save the configuration of  CPU module and expansion modules. <\/li>\n<li>Through the memory card, it allows you to restore the system when updating the PLC firmware and when unrecoverable OS failure occurs. <\/li>\n<li>The Ladder project saved in memory card is protected with password. <\/li>\n<li>Data collection function, allowing the user to upload the data to PC. <\/li>\n<li>Through the command, you may use the memory card to read and write the address data of the program-specific register. <\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>For detailed introduction on the functions of SD card, please refer to M PLC Function and Application User Manual. <\/p>\n<p>6. \tCPU modules can be connected with each other through the Ethernet<\/p>\n<p>It uses the network port of PC and the Ethernet port of CPU as the communication interface. <\/p>\n<p>Through the modem or the hub, you may connect several units of programming software or other IoT devices without changing the cable. <\/p>\n<p>7. \tExpanding the system by I\/O bus extension modules<\/p>\n<p>Through these I\/O bus extension modules(Repeater\u3001Branch\u3001Gateway\u3001Head\u3001Tail modules), we can expand the system up to 64 expansion modules, and up to 2048 DI\/DO points. <\/p>\n<p>8. \tApplication of physical RUN\/STOP Switch<\/p>\n<p>Through physical switch, it can define the RUN\/STOP status. Through the UperLogic software, it can determine the RUN\/STOP status. For detailed description of combining the aforesaid two methods, please refer to \u201c5.1 CPU Interface\u201d section. <\/p>\n<h3>2-2 Composition of M-Series PLC Single Model System Types<\/h3>\n<p>The single model system refers to the resources (including the max. I\/O and communication that can be expanded by the host) that can be controlled by each individual host (CPU module). Indicated below is the resource schematic diagram relating to the M-Series PLC Single Model System. <\/p>\n<p>Support up to 16 units of EtherCAt communication servo system.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-02\/mplc-m01-en-02-002.png\" \/><\/p>\n<p>Single Model System Diagram <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2460<\/p>\n<\/td>\n<td>\n<p>Power module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2461<\/p>\n<\/td>\n<td>\n<p>CPU module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2462<\/p>\n<\/td>\n<td>\n<p>RS485 module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2463<\/p>\n<\/td>\n<td>\n<p>RS232 module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2464<\/p>\n<\/td>\n<td>\n<p>DI\/DO module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2465<\/p>\n<\/td>\n<td>\n<p>AO (DA) module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2466<\/p>\n<\/td>\n<td>\n<p>AI (AD) module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2467<\/p>\n<\/td>\n<td>\n<p>TC module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2468<\/p>\n<\/td>\n<td>\n<p>LC module<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2469<\/p>\n<\/td>\n<td>\n<p>End module<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Product Line FATEK M-Series PLC is designed as a modula [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[45],"tags":[],"class_list":["post-3174","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m01"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3174"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3174\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}