{"id":3182,"date":"2026-11-17T18:37:58","date_gmt":"2026-11-17T10:37:58","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m01-en-10\/"},"modified":"2026-11-17T18:37:58","modified_gmt":"2026-11-17T10:37:58","slug":"mplc-m01-en-10","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m01-en-10\/","title":{"rendered":"Hardware Installation and Wiring"},"content":{"rendered":"<p><strong>Hardware Installation and Wiring<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Caution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>&#8211; The installation that the safety of any system incorporating the equipment is the responsibility of the assembler of the system.<\/p>\n<p> L&#8217;installation ainsi que la s\u00e9curit\u00e9 de tout syst\u00e8me int\u00e9grant l&#8217;\u00e9quipement rel\u00e8vent de la responsabilit\u00e9 de l&#8217;assembleur du syst\u00e8me.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-001.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>&#8211; If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.<\/p>\n<p> Si l&#8217;\u00e9quipement est utilis\u00e9 d&#8217;une mani\u00e8re non sp\u00e9cifi\u00e9e par le fabricant, la protection fournie par l&#8217;\u00e9quipement peut \u00eatre alt\u00e9r\u00e9e.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-002.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>This section describes the assembly method of the power module and CPU module as well as the fixed guide rail installation method and the wiring method. <\/p>\n<p>For detailed installation and wiring method of other expansion modules, please refer to \u201cExpansion Module Operating Manual.\u201d<\/p>\n<h3>10-1  Installation<\/h3>\n<p>When connecting the module, it shall be executed after the power is disconnected and it is also required to follow safety instructions. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-003.png\" \/><\/p>\n<p>Power Module          CPU Module          Expansion    End<\/p>\n<p>Module      Module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Precaution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The final module on the rightmost end should be equipped with a termination cover plate during the installation process.  <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Pr\u00e9caution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Le dernier module \u00e0 l&#8217;extr\u00e9mit\u00e9 droite doit \u00eatre \u00e9quip\u00e9 d&#8217;une plaque d&#8217;obturation lors de l&#8217;installation.  <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<ul>\n<li>Installation position<\/li>\n<\/ul>\n<p>Installation direction: When installed in the panel, the front-side panel of the CPU Module should<\/p>\n<p>face forward.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-004.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-005.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-006.png\" \/><\/p>\n<ul>\n<li>Separate with peripheral environment<\/li>\n<\/ul>\n<p>The M-Series PLC Module is designed with natural air convection to dissipate the heat. For this reason, the upper side and the bottom side of the PLC must also be reserved with a gap wider than 50mm for easier heat dissipation, per the figure below: <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-007.png\" \/>When exceeding the working environment temperature, please use the forced cooling method, or widen the spacing with peripheral environment or improve the ventilation effect to reduce the temperature. When using the expansion module, it is also required to consider the heat effect by widening the space between upper and lower modules for over 50mm. <\/p>\n<h4>10-1-1 Module assembly                                                           <\/h4>\n<p>Regarding the connection between the M-Series PLC Module and other modules, the assembly of the M-Series CPU Module and the power module will be used as the example for explanation as below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-008.jpg\" \/><\/p>\n<ol>\n<li>Release the Side Buckle\/Side Slider at the upper\/lower side of the high speed or local I\/O module. <\/li>\n<\/ol>\n<ul>\n<li>Put your finger on the protruding point of the Side Buckle and then push it towards you<em>, i.e.,<\/em> sliding it towards the front side of the module until the module is ready for installation.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-009.png\" \/>2. \tMove the hook hole of the high speed or local I\/O module towards the left and then insert it into the hook of the advanced module.  <\/p>\n<ul>\n<li>Keep both module parallel to each other. The connection is completed when the butting connection heads of the expansion modules are aligned with each other. <\/li>\n<\/ul>\n<p>3. \tSecure the side buckles at the upper and lower sides of the high speed or local I\/O module. <\/p>\n<ul>\n<li><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-010.png\" \/>Put your finger on the protruding point of the Side Buckle and then push it outward, <em>i.e.,<\/em> sliding it towards the backside front of the module until the module goes into the LOCK status. <\/li>\n<\/ul>\n<p>4. \tFinally, install the termination cover plate on the rightmost end of the entire row of modules. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-011.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Precaution<\/p>\n<\/td>\n<td>\n<p>Please secure the neighboring module with the Side Buckle. If not secured correctly, it may cause a loosening of the connection between both modules such that the PLC will not be able to operate normally. After being latched, test with your hand to see if both modules are securely connected. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-012.jpg\" \/>Pr\u00e9caution<\/p>\n<\/td>\n<td>\n<p>Veuillez vous assurer d\u2019utiliser correctement les clips lat\u00e9raux afin de fixer solidement les modules adjacents. En cas de fixation incorrecte, la connexion entre les modules peut devenir l\u00e2che, ce qui peut entra\u00eener un dysfonctionnement du PLC. Une fois la fixation termin\u00e9e, testez l\u00e9g\u00e8rement la connexion \u00e0 la main pour v\u00e9rifier sa stabilit\u00e9.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>10-1-2 <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-013.png\" \/> Securing the DIN guide rail                                                 <\/h4>\n<p>This section describes how to install the connected modules onto the DIN guide rail and the relevant dismantling method.<\/p>\n<p>Install onto the DIN guide rail<\/p>\n<p>1. \tHook the groove at the upper side groove of the DIN guide rail onto the guide rail installation latch-hook mounted at the upper side of each module. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-014.png\" \/>2. \tInsert the lower side of the guide rail into the DIN guide rail mounting latch-hook at the lower side of each module. <\/p>\n<ul>\n<li>Push the bottom-side latch-hook to the pull-out status with a flat-head screwdriver.  After hearing a click sound, push the module against the DIN guide rail and then lift the bottom-side installation latch-hook to the inserted  status. <\/li>\n<li><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-015.jpg\" \/>When used in the location difficult for installation, dismantle all of the side buckles first and then lock them tightly after being installed onto the guide rail. <\/li>\n<li>Check if the lower-side guide rail installation latch-hook is under the inserted status (locking status).<\/li>\n<\/ul>\n<p>Dismantling method<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-016.png\" \/>3. \tPush the lower-side guide rail installation latch-hook to the pull-out status.<\/p>\n<p>4. \tDismantle the guide rail from the module according to the reverse procedure to the installation. <\/p>\n<h4>10-1-3 Cautions for distribution panel assembly                                      <\/h4>\n<p>When installing the PLC in the control panel, it should be executed in an appropriate operating environment.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Temperature control<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" alt=\"C:\\Users\\fatek\\Desktop\\\u672a\u5b8c\u6210\\CPU\u624b\u518a\\hank\\M PLC  Manual Material-21.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-017.png\" \/>The environment temperature in the Control Box must be maintained at between 0<sup>0<\/sup>C and 55<sup>0<\/sup>C. If required, use the following method to maintain it at appropriate temperature level. <\/p>\n<ul>\n<li>Provide sufficient space in order to maintain effective air circulation. <\/li>\n<li>Do not install the PLC near equipment that will produce high heat such as heater, transformer or high power resistor. <\/li>\n<li>If the environment temperature is exceeding 55<sup>0<\/sup>C, then such environment shall be provided with a cooling fan or an air-conditioning system. <\/li>\n<\/ul>\n<p>La temp\u00e9rature de l&#8217;environnement dans le bo\u00eetier de contr\u00f4le doit \u00eatre maintenue entre 00C et 550C. Si n\u00e9cessaire, utilisez la m\u00e9thode suivante pour la maintenir au niveau de temp\u00e9rature appropri\u00e9. <\/p>\n<ul>\n<li>Pr\u00e9voir un espace suffisant pour maintenir une circulation d&#8217;air efficace. <\/li>\n<li>N&#8217;installez pas l&#8217;automate \u00e0 proximit\u00e9 d&#8217;\u00e9quipements produisant une chaleur \u00e9lev\u00e9e, tels qu&#8217;un chauffage, un transformateur ou une r\u00e9sistance de forte puissance. <\/li>\n<li>Si la temp\u00e9rature de l&#8217;environnement d\u00e9passe 550\u00b0C, cet environnement doit \u00eatre \u00e9quip\u00e9 d&#8217;un ventilateur de refroidissement ou d&#8217;un syst\u00e8me de climatisation.<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Operations and maintenance<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<ul>\n<li>Keep the PLC away from high-voltage equipment and motorized machineries in order to ensure the safety when executing the operations and maintenance activities. <\/li>\n<li>Install the PLC at a location higher than the ground for 1.0~1.6m because such location will be most suitable for executing the PLC installation and operations. <\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Improve the interference resistant performance<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When laying the communication cables at an outdoor location, the following factors should be considered:<\/p>\n<ul>\n<li>When using multi-core signal cables, do not install the I\/O wires and other type of control wires in the same strand of cable.<\/li>\n<li>When using a parallel layout, a minimum 300mm gap should be maintained between the distribution frames. <\/li>\n<li>If it is required to lay the I\/O wires and the power cable in the same cable trough, then the grounding metal plate shall be used to separate both cables. <\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-018.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-019.png\" \/><\/p>\n<p>On-board configuration example<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>PLC grounding<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When the terminals are properly grounded, the noise from the power supply can be attenuated. The following are the key points for grounding M series PLCs.<\/p>\n<ul>\n<li>The \u23da contact of the MPA module is the equipment ground. When using it, a dedicated ground should be used as much as possible. Under normal circumstances, no current flows in the ground wire (it must not be shared with other return circuits with current return).<\/li>\n<li>Do not share grounding with large electric machines such as motors\/inverters. Grounding should be set individually to avoid mutual influence.<\/li>\n<li>When using the \u23da contact of the MPA module, the common mode noise of the power supply may be attenuated, but sometimes it may cause noise reception due to grounding. If grounding still cannot improve the noise situation, it is recommended to remove it.<\/li>\n<li>When using the G contact of the communication module for grounding, this contact is the signal ground and should be connected together with the G contacts of other communication modules. The G contact should not be connected to the system ground point.<\/li>\n<\/ul>\n<h3>10-2  Wiring<\/h3>\n<p>Precautions for the wiring operations<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Precautions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Do not attempt to execute the installation or the wiring activities under energized conditions or it may cause the electrocution of the operator or product damage. <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-020.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The product should be properly grounded according to the grounding symbols marked on the equipment in order to keep the product from executing false actions as maybe caused by the electrocution and noise interference. <\/p>\n<p>When connecting the wires between the peripheral devices and the PLC, please check if the product specifications are compatible with the selected PLC. Unsuitable  peripheral devices may result in incompatible terminal configuration or incorrect power. In this case, it may not be able to activate the equipment or may even generate hazardous situation such as the equipment burning damage due to the short circuit of the wires.<\/p>\n<p>It is required to ensure that foreign matter such as iron chips or wiring residues are not remain in the module, because these foreign matter may cause fire, damage or false working results. <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-021.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<ul>\n<li>Grounding<\/li>\n<\/ul>\n<p>(1) \tPlease use independent correct grounding method. <\/p>\n<p>(2) \tThe grounding should be achieved with the cable with sectional profile greater than or equal to 2mm. <\/p>\n<p>(3) \tThe grounding point should be closer to the PLC as much as possible in order to connect with the grounding cable securely. <\/p>\n<p>Pr\u00e9cautions pour les op\u00e9rations de c\u00e2blage<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Pr\u00e9cautions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>&#8211; N&#8217;essayez pas d&#8217;effectuer l&#8217;installation ou le c\u00e2blage dans des conditions d&#8217;alimentation \u00e9lectrique, sous peine d&#8217;\u00e9lectrocuter l&#8217;op\u00e9rateur ou d&#8217;endommager le produit.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-022.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>&#8211; Le produit doit \u00eatre correctement mis \u00e0 la terre conform\u00e9ment aux symboles de mise \u00e0 la terre marqu\u00e9s sur l&#8217;\u00e9quipement afin d&#8217;\u00e9viter que le produit n&#8217;ex\u00e9cute des actions erron\u00e9es pouvant \u00eatre caus\u00e9es par l&#8217;\u00e9lectrocution et les interf\u00e9rences sonores. <\/p>\n<p>&#8211; Lors de la connexion des fils entre les p\u00e9riph\u00e9riques et l&#8217;automate, veuillez v\u00e9rifier si les sp\u00e9cifications du produit sont compatibles avec l&#8217;automate s\u00e9lectionn\u00e9. Des p\u00e9riph\u00e9riques inadapt\u00e9s peuvent entra\u00eener une configuration incompatible des bornes ou une alimentation incorrecte. Dans ce cas, il peut \u00eatre impossible d&#8217;activer l&#8217;\u00e9quipement ou m\u00eame g\u00e9n\u00e9rer des situations dangereuses telles que la br\u00fblure de l&#8217;\u00e9quipement en raison d&#8217;un court-circuit des fils.<\/p>\n<p>&#8211; Il est n\u00e9cessaire de s&#8217;assurer que des corps \u00e9trangers tels que des copeaux de fer ou des r\u00e9sidus de c\u00e2blage ne restent pas dans le module, car ces corps \u00e9trangers peuvent provoquer un incendie, des dommages ou des r\u00e9sultats de travail erron\u00e9s. <\/p>\n<p>&#8211; The product is Open type, intended to be installed in a final enclosure.<\/p>\n<p>&#8211; C\u00e2blage de la fiche du bornier d&#8217;alimentation, taille 12-28 AWG.<\/p>\n<p>&#8211; La temp\u00e9rature nominale du fil d&#8217;alimentation utilis\u00e9 doit \u00eatre d&#8217;au moins 105\u00b0C.<\/p>\n<p>&#8211; Utiliser uniquement des conducteurs en cuivre.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-023.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<ul>\n<li>Mise \u00e0 la terre<\/li>\n<\/ul>\n<p>(1) Veuillez utiliser une m\u00e9thode de mise \u00e0 la terre ind\u00e9pendante et correcte. <\/p>\n<p>(2) La mise \u00e0 la terre doit \u00eatre r\u00e9alis\u00e9e \u00e0 l&#8217;aide d&#8217;un c\u00e2ble dont le profil de section est sup\u00e9rieur ou \u00e9gal \u00e0 2 mm. <\/p>\n<p>(3) Le point de mise \u00e0 la terre doit \u00eatre le plus proche possible de l&#8217;automate afin de se connecter au c\u00e2ble de mise \u00e0 la terre en toute s\u00e9curit\u00e9.<\/p>\n<h4>10-2-1 Power wiring                                                                <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<h5>Power preventive measures<\/h5>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> (1) The power cord of the M-Series Power Module should be configured by separating the power cord of I\/O device and other devices, as indicated in the figure below. If a stronger noise is expected, then it shall be equipped with an additional Isolation transformer.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-024.png\" \/><\/p>\n<p>(2) AC110V and 220V cables should be arranged by separating with DC24V cables. These power wires shall be finely stranded to prevent noise interference. In the meantime, the cable shall be connected to the module with shorter length.  <\/p>\n<p>(3) Do not wrap AC110V, AC220V and DC24V cables together with the main circuit (high-voltage\/large current) or I\/O signal wires and do not lay the cables by keeping them closer to each other. If allowed by the environment, the aforesaid cables should be separated from each other for over 100mm. <\/p>\n<p>(4) To prevent the surge resulting from lightning, please install the surge absorber according to the method indicated in the figure below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-025.png\" \/><\/p>\n<p>Cautions: <\/p>\n<p>1. The grounding wire of the Surge Arrestor should be configured by separating it from that of PLC System. <\/p>\n<p>2. Please select the surge absorber with a working voltage not less than the allowable maximum input voltage.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<h5>Mesures pr\u00e9ventives en mati\u00e8re d&#8217;\u00e9lectricit\u00e9<\/h5>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>(1) Le cordon d&#8217;alimentation du module d&#8217;alimentation de la s\u00e9rie M doit \u00eatre configur\u00e9 en s\u00e9parant le cordon d&#8217;alimentation du dispositif d&#8217;E\/S et d&#8217;autres dispositifs, comme indiqu\u00e9 dans la figure ci-dessous. Si un bruit plus fort est attendu, il doit \u00eatre \u00e9quip\u00e9 d&#8217;un transformateur d&#8217;isolation suppl\u00e9mentaire.<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-026.png\" \/><\/p>\n<p>(2) Les c\u00e2bles AC110V et 220V doivent \u00eatre s\u00e9par\u00e9s des c\u00e2bles DC24V. Ces c\u00e2bles d&#8217;alimentation doivent \u00eatre finement toronn\u00e9s pour \u00e9viter les interf\u00e9rences sonores. Entre-temps, le c\u00e2ble doit \u00eatre connect\u00e9 au module avec une longueur plus courte.  <\/p>\n<p>(3) Ne pas enrouler les c\u00e2bles AC110V, AC220V et DC24V avec les fils du circuit principal (haute tension\/grand courant) ou les fils de signal E\/S et ne pas poser les c\u00e2bles en les rapprochant les uns des autres. Si l&#8217;environnement le permet, les c\u00e2bles susmentionn\u00e9s doivent \u00eatre s\u00e9par\u00e9s les uns des autres de plus de 100 mm. <\/p>\n<p>(4) Pour \u00e9viter les surtensions dues \u00e0 la foudre, veuillez installer l&#8217;absorbeur de surtensions conform\u00e9ment \u00e0 la m\u00e9thode indiqu\u00e9e dans la figure ci-dessous. <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-027.png\" \/><\/p>\n<p>Pr\u00e9cautions : <\/p>\n<p>1. Le fil de mise \u00e0 la terre du limiteur de surtension doit \u00eatre configur\u00e9 en le s\u00e9parant de celui du syst\u00e8me PLC. <\/p>\n<p>2. Veuillez s\u00e9lectionner l&#8217;absorbeur de surtension dont la tension de fonctionnement n&#8217;est pas inf\u00e9rieure \u00e0 la tension d&#8217;entr\u00e9e maximale autoris\u00e9e.<\/p>\n<h4>10-2-2 AC power wiring                                                             <\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-028.png\" \/><\/p>\n<p>AC Power Loop<\/p>\n<p>1. Connect the FG (\u23da) of the Power Module to the grounded end of the power source for use as the reference grounded standard to prevent the system from acting abnormally. <\/p>\n<p>2. Connect the \u201cL\u201d and \u201cN\u201d of the AC power wire to the \u201cL\u201d and \u201cN\u201d of the Power Module, respectively. <\/p>\n<p>The input type shall be AC input. When using, please check the following: <\/p>\n<p>\u25a0 Because the input voltage of the AC power is presented in a wider range (100~240VAC), please connect the power to the \u201cL\u201d and \u201cN\u201d terminals. It will result in PLC damage if connecting the AC110V or AC220V to the \u201c+24V\u201d and \u201c-24V\u201d input ends. Therefore, users shall pay special attention to this point.<\/p>\n<p>\u25a0 The grounded end of the power uses over 1.6mm wire for carrying out the grounding purpose. <\/p>\n<p>\u25a0 If the power outage duration is less than 10ms, then the PLC will keep operating without any influence. If the power outage duration is too long or if the voltage is dropping, then it will force the PLC to stop running and then the output ends will also be disconnected in the meantime. When restoring the power, the PLC will resume running automatically. (The PLC is provided with auxiliary relay and register for supplying the power continuously during a power outage period. During the program design and planning stage, the user shall use these functions carefully.)<\/p>\n<p>3. The DC power supply of the power module is the output side of the power supply, please do not use it in parallel with other power supplies.<\/p>\n<h4>10-2-3 DC wiring                                                                   <\/h4>\n<ol>\n<li>MPLC-Series CPU Module can be activated through the plug-in 24V DC power. Per the figure below, the module is connected to the power socket on the left- side of the CPU module through a 3-pin EU-standard terminal plug. <\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-029.png\" \/><\/p>\n<ol>\n<li><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-030.jpg\" \/>When connecting the DC power, be sure to confirm that it has been properly connected to the positive and negative poles; otherwise, it may result in equipment damage. Please connect the wires according to the correct method indicated in the figure below. <\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-031.png\" \/><\/p>\n<p>Cautions<\/p>\n<p>1. \tThe grounded wire should be connected separately. If separate grounding becomes impossible, please use common grounding, but the same wire length must be used.  <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-032.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-033.png\" \/>2. \tPlease use the FG terminal as the grounded end (do not use the power terminal as the grounding end).<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-034.png\" \/><\/p>\n<h3>10-3   Compact module expansion board installation<\/h3>\n<ol>\n<li>Press the buckles on the top and bottom of the expansion bezel and pull up the expansion bezel.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-035.png\" \/><\/p>\n<p>Remove expansion baffle method<\/p>\n<ol>\n<li>Cut off the support piece at the yellow dotted line of the expansion board bracket in the picture below according to different types of expansion boards.<\/li>\n<\/ol>\n<p>Expansion board model: MB-CB5, MB-2HSC, MB-4X, MB-2PSO\u25c7, MB-4Y\u25c7.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-036.png\" \/><\/p>\n<p>Expansion board model: MB-CB2<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-037.jpg\" \/><\/p>\n<p>Expansion board model: MB-CBES, MB-CBEH<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-038.png\" \/><\/p>\n<ol>\n<li>Insert the expansion board along the groove inside the expansion board bracket (indicated by the black arrow).<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-039.png\" \/><\/p>\n<p>How to install the expansion board to the expansion board bracket<\/p>\n<ol>\n<li>Attach the nameplate that comes with the expansion board.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-040.png\" \/><\/p>\n<p>Attach the nameplate of the expansion board<\/p>\n<ol>\n<li>Install the expansion board including the expansion bracket to the MQ series host.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-041.png\" \/><\/p>\n<p>Install expansion boards including expansion brackets to the MQ series host<\/p>\n<ol>\n<li>Press the buckles on the top and bottom of the expansion bracket, and use a flat-blade screwdriver to lift the expansion bracket at the point indicated by the black arrow.<\/li>\n<\/ol>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u5beb\u751f, \u5716\u756b, \u5de5\u7a0b\u88fd\u5716, \u5716\u89e3 \u7684\u5716\u7247\n\n\u81ea\u52d5\u7522\u751f\u7684\u63cf\u8ff0\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m01-en-10\/mplc-m01-en-10-042.png\" \/><\/p>\n<p>Remove the expansion bracket containing the expansion board<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hardware Installation and Wiring Caution &#8211; The in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[45],"tags":[],"class_list":["post-3182","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m01"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3182"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3182\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3182"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3182"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}