{"id":3192,"date":"2026-11-17T18:38:05","date_gmt":"2026-11-17T10:38:05","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-07\/"},"modified":"2026-11-17T18:38:05","modified_gmt":"2026-11-17T10:38:05","slug":"mplc-m02-en-07","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-07\/","title":{"rendered":"Chapter 7 Advanced Expansion &#038; Power Modules Specifications"},"content":{"rendered":"<h3>7-1 Power Module Specifications<\/h3>\n<h4>7-1-1 MPA024-24 Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-07\/mplc-m02-en-07-001.png\" \/><\/p>\n<p>MPA024-24\u90e8\u4f4d\u540d\u7a31<\/p>\n<p>Technical Specifications<\/p>\n<p>MPA024-24 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MPA024-24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\">\n<p>Input<\/p>\n<\/td>\n<td>\n<p>Input voltage<\/p>\n<\/td>\n<td>\n<p>100~240VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum input current<\/p>\n<\/td>\n<td>\n<p>1A max.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inrush current\uff08cold start\uff09<\/p>\n<\/td>\n<td>\n<p>22A\/115Vac (44A\/230Vac)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand voltage<\/p>\n<\/td>\n<td>\n<p>3,000 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC<\/p>\n<p>(Secondary-PE)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation resistance<\/p>\n<\/td>\n<td>\n<p>&gt;100M\u03a9\/500VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fuse<\/p>\n<\/td>\n<td>\n<p>2A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hold-up time<\/p>\n<\/td>\n<td>\n<p>&gt;15ms\/ 115VAC\uff0c&gt;60ms\/ 220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power indication<\/p>\n<\/td>\n<td>\n<p>LED (green)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>output<\/p>\n<\/td>\n<td>\n<p>Rated output power<\/p>\n<\/td>\n<td>\n<p>24W (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated output current<\/p>\n<\/td>\n<td>\n<p>1A (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output voltage range<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b11%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion efficiency<\/p>\n<\/td>\n<td>\n<p>86%\/110VAC\uff0c87%\/220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Protection<\/p>\n<\/td>\n<td>\n<p>Overvoltage protection<\/p>\n<\/td>\n<td>\n<p>Latching overvoltage protection, re-power on to recover<\/p>\n<p>34V~36V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Overcurrent protection<\/p>\n<\/td>\n<td>\n<p>Method: Foldback overload protection, automatically recover when overload is removed<\/p>\n<p>101%~133% rated output power<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Certification<\/p>\n<\/td>\n<td>\n<p>CE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MPA024-24 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>7-1-2 MPA048-24 Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-07\/mplc-m02-en-07-002.png\" \/><\/p>\n<p>MPA048-24 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MPA048-24 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MPA048-24<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\">\n<p>Input<\/p>\n<\/td>\n<td>\n<p>Input voltage<\/p>\n<\/td>\n<td>\n<p>100~240VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum input current<\/p>\n<\/td>\n<td>\n<p>1A max.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inrush current\uff08cold start\uff09<\/p>\n<\/td>\n<td>\n<p>22A\/115Vac (44A\/230Vac)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand voltage<\/p>\n<\/td>\n<td>\n<p>3,000 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC<\/p>\n<p>(Secondary-PE)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation resistance<\/p>\n<\/td>\n<td>\n<p>&gt;100M\u03a9\/500VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fuse<\/p>\n<\/td>\n<td>\n<p>2A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hold-up time<\/p>\n<\/td>\n<td>\n<p>&gt;15ms\/ 115VAC\uff0c&gt;60ms\/ 220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power indication<\/p>\n<\/td>\n<td>\n<p>LED (green)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>output<\/p>\n<\/td>\n<td>\n<p>Rated output power<\/p>\n<\/td>\n<td>\n<p>48W (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated output current<\/p>\n<\/td>\n<td>\n<p>2A (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output voltage range<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b11%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion efficiency<\/p>\n<\/td>\n<td>\n<p>86%\/110VAC\uff0c87%\/220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Protection<\/p>\n<\/td>\n<td>\n<p>Overvoltage protection<\/p>\n<\/td>\n<td>\n<p>Latching overvoltage protection, re-power on to recover<\/p>\n<p>34V~36V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Overcurrent protection<\/p>\n<\/td>\n<td>\n<p>Method: Foldback overload protection, automatically recover when overload is removed<\/p>\n<p>101%~133% rated output power<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Certification<\/p>\n<\/td>\n<td>\n<p>CE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MPA048-24 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>7-1 Power Module Specifications 7-1-1 MPA024-24 Specifi [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[],"class_list":["post-3192","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m02"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3192"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3192\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3192"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3192"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}