{"id":3193,"date":"2026-11-17T18:38:05","date_gmt":"2026-11-17T10:38:05","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-08\/"},"modified":"2026-11-17T18:38:05","modified_gmt":"2026-11-17T10:38:05","slug":"mplc-m02-en-08","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-08\/","title":{"rendered":"Chapter 8 Plug-in Expansion Boards Specifications"},"content":{"rendered":"<h3>8-1 Communication Plug-in Expansion Boards Specifications<\/h3>\n<p>If the communication Port of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in Expansion Boards.<\/p>\n<h4>8-1-1 MB-CB2 Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-001.png\" \/><\/p>\n<p>MB-CB2 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-CB2 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-CB2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connection interface<\/p>\n<\/td>\n<td>\n<p>1 Port RS232<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum number of connections<\/p>\n<\/td>\n<td>\n<p>1 Slave<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connector type<\/p>\n<\/td>\n<td>\n<p>D-Sub 9-Pins<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Transmission rate<\/p>\n<\/td>\n<td>\n<p>Max 115200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum cable length<\/p>\n<\/td>\n<td>\n<p>15M*<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* It varies based on cable material, communication speed and usage environment.<\/p>\n<p>Status Indicator<\/p>\n<p>MB-CB2 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RX Port Indicator<\/p>\n<\/td>\n<td>\n<p>Port is receiving: yellow-green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>TX Port Indicator<\/p>\n<\/td>\n<td>\n<p>Port is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pin assignment of the connector<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u5beb\u751f, \u5716\u756b, \u5716\u8868, \u5713\u5f62 \u7684\u5716\u7247\n\n\u81ea\u52d5\u7522\u751f\u7684\u63cf\u8ff0\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-002.png\" \/><\/p>\n<p>MB-CB2 Pins<\/p>\n<h4>8-1-2 MB-CB5 Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-003.png\" \/><\/p>\n<p>MB-CB5 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-CB5 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-CB5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connection interface<\/p>\n<\/td>\n<td>\n<p>1 Port RS485<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum number of connections<\/p>\n<\/td>\n<td>\n<p>32 Slaves<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connector type<\/p>\n<\/td>\n<td>\n<p>5 pins spring terminal<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Transmission rate<\/p>\n<\/td>\n<td>\n<p>Max 230400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum cable length<\/p>\n<\/td>\n<td>\n<p>1200M*<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* It varies based on cable material, communication speed and usage environment.<\/p>\n<p>Status Indicator<\/p>\n<p>MB-CB5 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RX Port Indicator<\/p>\n<\/td>\n<td>\n<p>Port is receiving: yellow-green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>TX Port Indicator<\/p>\n<\/td>\n<td>\n<p>Port is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pin assignment of the connector<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u5beb\u751f, \u5716\u756b, \u5716\u8868, \u5de5\u7a0b\u88fd\u5716 \u7684\u5716\u7247\n\n\u81ea\u52d5\u7522\u751f\u7684\u63cf\u8ff0\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-004.png\" \/><\/p>\n<p>MB-CB5 Pins<\/p>\n<h4>8-1-3 MB-CBEQ Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-005.png\" \/><\/p>\n<p>MB-CBEQ Specifications<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-CB5 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-CBEQ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Network interface<\/p>\n<\/td>\n<td>\n<p>10\/100Base T<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Internet Protocol<\/p>\n<\/td>\n<td>\n<p>TCP\/IP<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* It varies based on cable material, communication speed and usage environment.<\/p>\n<h3>8-2 High Speed Digital Input Plug-in Expansion Boards Specifications<\/h3>\n<p>If the input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in expansion boards.<\/p>\n<h4>8-2-1 MB-2HSC Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-006.png\" \/><\/p>\n<p>MB-2HSC Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-2HSC Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-2HSC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points Type<\/p>\n<\/td>\n<td>\n<p>24VDC Single-end input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum input frequency<\/p>\n<\/td>\n<td>\n<p>High Speed Counter\uff0c200kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Signal Voltage<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b110%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input<\/p>\n<p>Current<\/p>\n<p>Threshold<\/p>\n<\/td>\n<td>\n<p>ON Current<\/p>\n<\/td>\n<td>\n<p>\uff1e4mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF Current<\/p>\n<\/td>\n<td>\n<p>\uff1c2mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Input Current<\/p>\n<\/td>\n<td>\n<p>6mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Resistance<\/p>\n<\/td>\n<td>\n<p>3.3k\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Wiring<\/p>\n<\/td>\n<td>\n<p>Via variation of internal common terminal S\/S and external common wiring<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Filtering Time Constant<\/p>\n<\/td>\n<td>\n<p>DHF(0 ~ 15ms)\uff0bAHF(0.47\u03bcs)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-2HSC Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~4 Input Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Wiring of single-end common SINK input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-007.png\" \/><\/p>\n<p>Wiring of single-end common SINK input<\/p>\n<ul>\n<li>Wiring of single-end common SOURCE input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-008.png\" \/><\/p>\n<p>Wiring of single-end common SOURCE input<\/p>\n<h4>8-2-2 MB-4X Specifications<\/h4>\n<p>If the input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in expansion boards.<\/p>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-009.png\" \/><\/p>\n<p>MB-4X Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-4X Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-4X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points Type<\/p>\n<\/td>\n<td>\n<p>24VDC Single-end input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum input frequency<\/p>\n<\/td>\n<td>\n<p>1kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Signal Voltage<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b110%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input<\/p>\n<p>Current<\/p>\n<p>Threshold<\/p>\n<\/td>\n<td>\n<p>ON Current<\/p>\n<\/td>\n<td>\n<p>\uff1e4mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF Current<\/p>\n<\/td>\n<td>\n<p>\uff1c2mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Input Current<\/p>\n<\/td>\n<td>\n<p>6mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Resistance<\/p>\n<\/td>\n<td>\n<p>5.6k\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Wiring<\/p>\n<\/td>\n<td>\n<p>Via variation of internal common terminal S\/S and external common wiring<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Filtering Time Constant<\/p>\n<\/td>\n<td>\n<p>DHF(0 ~ 70ms)\uff0bAHF(0.47\u03bcs)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-4X Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~4 Input Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Wiring of single-end common SINK input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-010.png\" \/><\/p>\n<p>Wiring of single-end common SINK input<\/p>\n<ul>\n<li>Wiring of single-end common SOURCE input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-011.png\" \/><\/p>\n<p>Wiring of single-end common SOURCE input<\/p>\n<h3>8-3 High Speed Digital output Plug-in Expansion Boards Specifications<\/h3>\n<p>If the output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in Expansion Boards.<\/p>\n<h4>8-3-1 MB-2PSOT\/MB-2PSOJ Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-012.png\" \/><\/p>\n<p>MB-2PSOT Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-2PSOT\/MB-2PSOJ Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>model<\/p>\n<\/td>\n<td>\n<p>MB-2PSOT\/MB-2PSOJ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points Type<\/p>\n<\/td>\n<td>\n<p>Single-End Transistor Output; T-Transistor SINK(NPN) output; J-Transistor SOURCE(PNP) output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum output frequency<\/p>\n<\/td>\n<td>\n<p>High Speed Pulses Output\uff0c200kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Working Voltage<\/p>\n<\/td>\n<td>\n<p>5~30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Load<\/p>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>Resistive<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>0.1A\/Single<\/p>\n<p>0.4A\/COM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inductive<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Voltage Drop\/conducing resistance<\/p>\n<\/td>\n<td>\n<p>0.6V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Minimum Load<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Leakage Current<\/p>\n<\/td>\n<td>\n<p>\uff1c0.1mA\/30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Output<\/p>\n<p>Delay<\/p>\n<p>Time<\/p>\n<\/td>\n<td>\n<p>ON &gt; OFF<\/p>\n<\/td>\n<td>\n<p>\uff1c2\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF &gt; ON<\/p>\n<\/td>\n<td>\n<p>\uff1c2\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Over Current Protection<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Photocoupler Isolation, 500VAC, 1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Type<\/p>\n<\/td>\n<td>\n<p>Choose SINK\/SOURCE by models and non-exchangeable<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-2PSOT\/MB-2PSOJ Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~4 Output Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Transistor Single-End SINK Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-013.png\" \/><\/p>\n<p>Transistor Single-End SINK Output<\/p>\n<ul>\n<li>Transistor Single-End SOURCE Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-014.png\" \/><\/p>\n<p>Transistor Single-End SOURCE Output<\/p>\n<h4>8-3-2 MB-4YT\/MB-4YJ Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-015.png\" \/><\/p>\n<p>MB-4YT\/MB-4YJ Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-4YT\/MB-4YJ  Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>model<\/p>\n<\/td>\n<td>\n<p>MB-4YT\/MB-4YJ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points Type<\/p>\n<\/td>\n<td>\n<p>Single-End Transistor Output; T-Transistor SINK(NPN) output; J-Transistor SOURCE(PNP) output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum output frequency<\/p>\n<\/td>\n<td>\n<p>1kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Working Voltage<\/p>\n<\/td>\n<td>\n<p>5~30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Load<\/p>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>Resistive<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>0.1A\/Single<\/p>\n<p>0.4A\/COM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inductive<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Voltage Drop\/conducing resistance<\/p>\n<\/td>\n<td>\n<p>0.6V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Minimum Load<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Leakage Current<\/p>\n<\/td>\n<td>\n<p>\uff1c0.1mA\/30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Output<\/p>\n<p>Delay<\/p>\n<p>Time<\/p>\n<\/td>\n<td>\n<p>ON &gt; OFF<\/p>\n<\/td>\n<td>\n<p>\uff1c2\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF &gt; ON<\/p>\n<\/td>\n<td>\n<p>\uff1c2\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Over Current Protection<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Photocoupler Isolation, 500VAC, 1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Type<\/p>\n<\/td>\n<td>\n<p>Choose SINK\/SOURCE by models and non-exchangeable<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-4YT\/MB-4YJ Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~4 Output Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Transistor Single-End SINK Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-016.png\" \/><\/p>\n<p>Transistor Single-End SINK Output<\/p>\n<ul>\n<li>Transistor Single-End SOURCE Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-017.png\" \/><\/p>\n<p>Transistor Single-End SOURCE Output<\/p>\n<h3>8-4 Analog Input Plug-in Expansion Boards Specifications <\/h3>\n<p>If the output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in Expansion Boards.<\/p>\n<h4>8-4-1 MB-2ADL Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u6587\u5b57, \u5beb\u751f, \u5716\u8868, \u5716\u756b \u7684\u5716\u7247\n\nAI \u7522\u751f\u7684\u5167\u5bb9\u53ef\u80fd\u4e0d\u6b63\u78ba\u3002\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-018.png\" \/><\/p>\n<p>MB-2ADL Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>MB-2ADL Technical Specification Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>MB-2ADL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>PLC Scan Time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog input range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~ 4095<\/p>\n<\/td>\n<td>\n<p>2.44mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~ 4095<\/p>\n<\/td>\n<td>\n<p>4.88\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b11% (25\u00b0C\u00b15\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b11% (25\u00b0C\u00b15\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>12-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a100K\u2126 Current\uff1a125\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>None<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-2ADL Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ACT Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-019.png\" \/><\/p>\n<p>0.1~0.47 \u03bcF capacitor (for noise filtering) is recommended, though not mandatory.<\/p>\n<p>MB-2ADL Wiring<\/p>\n<h3>8-5 Analog Output Plug-in Expansion Boards Specifications<\/h3>\n<p>If the output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional plug-in Expansion Boards.<\/p>\n<h4>8-5-1 MB-2DAL Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u6587\u5b57, \u5beb\u751f, \u5716\u8868, \u5716\u756b \u7684\u5716\u7247\n\nAI \u7522\u751f\u7684\u5167\u5bb9\u53ef\u80fd\u4e0d\u6b63\u78ba\u3002\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-020.png\" \/><\/p>\n<p>MB-2DAL Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>MB-2DAL Technical Specification<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>MB-2DAL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>PLC Scan Time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Analog output characteristics and resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog output range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~4095<\/p>\n<\/td>\n<td>\n<p>2.44mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~4095<\/p>\n<\/td>\n<td>\n<p>1.22mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~4095<\/p>\n<\/td>\n<td>\n<p>4.88\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10mA<\/p>\n<\/td>\n<td>\n<p>0~4095<\/p>\n<\/td>\n<td>\n<p>2.44\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u2103\u00b15\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u2103\u00b15\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DA Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>12-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Minimum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a500~1M\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Current\uff1a0~500\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>None<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MB-2DAL Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ACT Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-021.png\" \/><\/p>\n<p>0.1~0.47 \u03bcF capacitor (for noise filtering) is recommended, though not mandatory.<\/p>\n<p>MB-2DAL Wiring<\/p>\n<h3>8-6 RTC Plug-in Expansion Boards Specifications<\/h3>\n<p>If the MQ series CPU module requires RTC function, then can expand it with the RTC plug-in expansion boards.<\/p>\n<h4>8-6-1 MB-RTC Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-08\/mplc-m02-en-08-022.png\" \/><\/p>\n<p>MB-RTC Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MB-RTC Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MB-RTC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Function<\/p>\n<\/td>\n<td>\n<p>Real Time Clock<\/p>\n<p>The RTC can keep time correctly regardless of whether the PLC is powered on or off.<\/p>\n<p>Provides 7 types of time including week, year, month, day, hour, minute, second&#8230;etc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>battery model<\/p>\n<\/td>\n<td>\n<p>CR2450 size non-charge battery <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Battery Life<\/p>\n<\/td>\n<td>\n<p>10 years*<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* It varies based on usage, environment, temperature or other conditions.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>8-1 Communication Plug-in Expansion Boards Specificatio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[],"class_list":["post-3193","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m02"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3193"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3193\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3193"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3193"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}