{"id":3194,"date":"2026-11-17T18:38:06","date_gmt":"2026-11-17T10:38:06","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-09\/"},"modified":"2026-11-17T18:38:06","modified_gmt":"2026-11-17T10:38:06","slug":"mplc-m02-en-09","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-09\/","title":{"rendered":"Chapter 9 High-Speed Expansion Modules Specifications"},"content":{"rendered":"<h3>9-1 High Speed Communication Expansion Module Specifications<\/h3>\n<p>If the communication Port of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>9-1-1 MHCM22 Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-001.png\" \/><\/p>\n<p>MHCM22 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MHCM22 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MHCM22<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connection interface<\/p>\n<\/td>\n<td>\n<p>2 Port RS232<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum number of connections<\/p>\n<\/td>\n<td>\n<p>1 Slave\/Port<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connector type<\/p>\n<\/td>\n<td>\n<p>D-Sub 9-Pins<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Transmission rate<\/p>\n<\/td>\n<td>\n<p>Max 115200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum cable length<\/p>\n<\/td>\n<td>\n<p>15M<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>isolation method<\/p>\n<\/td>\n<td>\n<p>Internal power isolation<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MHCM22 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pin assignment of the connector<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-002.png\" \/><\/p>\n<p>MHCM22 Pins<\/p>\n<h4>9-1-2 MHCM55 Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-003.png\" \/><\/p>\n<p>MHCM55 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MHCM55 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MHCM55<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connection interface<\/p>\n<\/td>\n<td>\n<p>2 Port RS485<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum number of connections<\/p>\n<\/td>\n<td>\n<p>32 Slaves\/Port<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connector type<\/p>\n<\/td>\n<td>\n<p>4 pins spring terminal<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Transmission rate<\/p>\n<\/td>\n<td>\n<p>Max 230400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum cable length<\/p>\n<\/td>\n<td>\n<p>1200M<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>isolation method<\/p>\n<\/td>\n<td>\n<p>Internal power isolation<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MHCM55 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pin assignment of the connector<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-004.png\" \/><\/p>\n<p>MHCM55 Pins<\/p>\n<h4>9-1-3 MHCM25 Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-005.png\" \/><\/p>\n<p>MHCM25 Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MHCM25 Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MHCM25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connection interface<\/p>\n<\/td>\n<td>\n<p>1 Port RS232\uff0b1 Port RS485<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum number of connections<\/p>\n<\/td>\n<td>\n<p>RS232: 1 Slave<\/p>\n<p>RS485: 32 Slaves<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Connector type<\/p>\n<\/td>\n<td>\n<p>RS232: D-Sub 9-Pins<\/p>\n<p>RS485:  4 pins spring terminal<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Transmission rate<\/p>\n<\/td>\n<td>\n<p>RS232: Max 115200<\/p>\n<p>RS485: Max 230400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum cable length<\/p>\n<\/td>\n<td>\n<p>RS232: 15M<\/p>\n<p>RS485: 1200M<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>isolation method<\/p>\n<\/td>\n<td>\n<p>Internal power isolation<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MHCM25 Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port A TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port A is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B RX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is receiving: orange light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Port B TX Indicator<\/p>\n<\/td>\n<td>\n<p>Port B is transmitting: orange light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pin assignment of the connector<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-09\/mplc-m02-en-09-006.png\" \/><\/p>\n<p>MHCM25 Pins<\/p>\n","protected":false},"excerpt":{"rendered":"<p>9-1 High Speed Communication Expansion Module Specifica [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[],"class_list":["post-3194","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m02"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3194"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3194\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}