{"id":3195,"date":"2026-11-17T18:38:11","date_gmt":"2026-11-17T10:38:11","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-10\/"},"modified":"2026-11-17T18:38:11","modified_gmt":"2026-11-17T10:38:11","slug":"mplc-m02-en-10","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m02-en-10\/","title":{"rendered":"Chapter 10 Local I O Expansion Modules Specifications"},"content":{"rendered":"<h2>Chapter 10 Local I\/O Expansion Modules Specifications<\/h2>\n<h3>10-1 Digital Input Expansion Module Specifications<\/h3>\n<p>If the input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-1-1 M16X Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-001.png\" \/><\/p>\n<p>M16X Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>M16X Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M16X<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points Type<\/p>\n<\/td>\n<td>\n<p>24VDC Single-end input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum input frequency<\/p>\n<\/td>\n<td>\n<p>Medium-Low Speed\uff0c1kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Signal Voltage<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b110%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input<\/p>\n<p>Current<\/p>\n<p>Threshold<\/p>\n<\/td>\n<td>\n<p>ON Current<\/p>\n<\/td>\n<td>\n<p>\uff1e4mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF Current<\/p>\n<\/td>\n<td>\n<p>\uff1c1.5mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Input Current<\/p>\n<\/td>\n<td>\n<p>7.6mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Resistance<\/p>\n<\/td>\n<td>\n<p>5.6k\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Wiring<\/p>\n<\/td>\n<td>\n<p>Via variation of internal common terminal S\/S and external common wiring<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Filtering Time Constant<\/p>\n<\/td>\n<td>\n<p>DHF(0 ~ 70ms)\uff0bAHF(0.47ms)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M16X Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>X1~X16 Input Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Wiring of single-end common SINK input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-002.png\" \/><\/p>\n<p>Wiring of single-end common SINK input<\/p>\n<ul>\n<li>Wiring of single-end common SOURCE input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-003.png\" \/><\/p>\n<p>Wiring of single-end common SOURCE input<\/p>\n<h3>10-2 Digital Output Expansion Module Specifications<\/h3>\n<p>If the output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-2-1 M16YT \/ M16YJ Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-004.png\" \/> <\/p>\n<p>M16Y Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>M16YT \/ M16YJ Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>model<\/p>\n<\/td>\n<td>\n<p>M16YT \/ M16YJ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points Type<\/p>\n<\/td>\n<td>\n<p>Single-End Transistor Output; T-Transistor SINK(NPN) output ; J-Transistor SOURCE(PNP) output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum output frequency<\/p>\n<\/td>\n<td>\n<p>Medium speed\uff0c1kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Working Voltage<\/p>\n<\/td>\n<td>\n<p>5~30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Load<\/p>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>Resistive<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>0.1A\/Single<\/p>\n<p>1.6A\/COM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inductive<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Voltage Drop\/conducing resistance<\/p>\n<\/td>\n<td>\n<p>2.2V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Minimum Load<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Leakage Current<\/p>\n<\/td>\n<td>\n<p>\uff1c0.1mA\/30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Output<\/p>\n<p>Delay<\/p>\n<p>Time<\/p>\n<\/td>\n<td>\n<p>ON &gt; OFF<\/p>\n<\/td>\n<td>\n<p>\uff1c10\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF &gt; ON<\/p>\n<\/td>\n<td>\n<p>\uff1c40\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Over Current Protection<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Photocoupler Isolation, 500VAC, 1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Type<\/p>\n<\/td>\n<td>\n<p>Choose SINK\/SOURCE by models and non-exchangeable<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M16YT \/ M16YJ Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y1~Y16 Output Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Transistor Single-End SINK Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-005.png\" \/><\/p>\n<p>Transistor Single-End SINK Output<\/p>\n<ul>\n<li>Transistor Single-End SOURCE Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-006.png\" \/><\/p>\n<p>Transistor Single-End SOURCE Output<\/p>\n<h4>10-2-2 M16YR Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-007.png\" \/><\/p>\n<p>M M16R Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M16YR Technical Specification Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M16YR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Output Points<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Output Points Type<\/p>\n<\/td>\n<td>\n<p>Single-End Relay Output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Maximum output frequency<\/p>\n<\/td>\n<td>\n<p>For ON\/OFF, not for frequently switching<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Working Voltage<\/p>\n<\/td>\n<td>\n<p>&lt;250VAC,30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Load<\/p>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Resistive<\/p>\n<\/td>\n<td>\n<p>2A\/single<\/p>\n<p>8A\/common<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Inductive<\/p>\n<\/td>\n<td>\n<p>80VA(AC)\/24VA(DC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Maximum Voltage<\/p>\n<p>Drop\/conducing resistance<\/p>\n<\/td>\n<td>\n<p>0.06V(Initial)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Minimum Load<\/p>\n<\/td>\n<td>\n<p>2mA\/DC Power<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Leakage Current<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Output<\/p>\n<p>Delay<\/p>\n<p>Time<\/p>\n<\/td>\n<td>\n<p>ON &gt; OFF<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>10ms<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF &gt; ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Over Current Protection<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Electromagnetic Isolation, 500VAC, <br \/>1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>SINK \/SOURCE Type<\/p>\n<\/td>\n<td>\n<p>Bilateral device, can be arbitrarily set to SINK\/SOURCE output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M16YR Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y1~Y16 Output Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Single-End Relay Output Circuit<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-008.png\" \/><\/p>\n<p>Single-End Relay Output Circuit<\/p>\n<h3>10-3 Digital Input \/Output Combo Expansion Module Specifications<\/h3>\n<p>If the I\/O point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-3-1 M1616XYT\/ M1616XYJ\/ M1616XYR Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-009.png\" \/><\/p>\n<p>M1616XYT \/ M1616XYJ Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>M1616XYT\/ M1616XYJ\/ M1616XYR Input Technical Specifications Table <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M1616XYT\/ M1616XYJ\/ M1616XYR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Points Type<\/p>\n<\/td>\n<td>\n<p>24VDC Single-end input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum input frequency<\/p>\n<\/td>\n<td>\n<p>Medium-Low Speed\uff0c1kHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Signal Voltage<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b110%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input<\/p>\n<p>Current<\/p>\n<p>Threshold<\/p>\n<\/td>\n<td>\n<p>ON Current<\/p>\n<\/td>\n<td>\n<p>\uff1e4mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF Current<\/p>\n<\/td>\n<td>\n<p>\uff1c1.5mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Input Current<\/p>\n<\/td>\n<td>\n<p>7.6mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Resistance<\/p>\n<\/td>\n<td>\n<p>5.6k\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Wiring<\/p>\n<\/td>\n<td>\n<p>Via variation of internal common terminal S\/S and external common wiring<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Filtering Time Constant<\/p>\n<\/td>\n<td>\n<p>DHF(0 ~ 70ms)\uff0bAHF(0.47ms)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>M1616XYT\/ M1616XYJ\/ M1616XYR Output Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>model<\/p>\n<\/td>\n<td>\n<p>M1616XYT\/ M1616XYJ<\/p>\n<\/td>\n<td>\n<p>M1616XYR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Output Points Type<\/p>\n<\/td>\n<td>\n<p>Single-End Transistor Output; T-Transistor SINK(NPN) output; J-Transistor SOURCE(PNP) output<\/p>\n<\/td>\n<td>\n<p>Single-End Relay Output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum output frequency<\/p>\n<\/td>\n<td>\n<p>Medium Speed\uff0c1kHz<\/p>\n<\/td>\n<td>\n<p>For ON\/OFF, not for frequently switching<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Working Voltage<\/p>\n<\/td>\n<td>\n<p>5~30VDC<\/p>\n<\/td>\n<td>\n<p>&lt;250VAC,30VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Load<\/p>\n<p>Current<\/p>\n<\/td>\n<td>\n<p>Resistive<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>0.1A<\/p>\n<\/td>\n<td>\n<p>2A\/single, 8A\/common<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inductive<\/p>\n<\/td>\n<td>\n<p>80VA(AC)\/24VA(DC)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Maximum Voltage Drop\/conducing resistance<\/p>\n<\/td>\n<td>\n<p>2.2V<\/p>\n<\/td>\n<td>\n<p>0.06V(Initial)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Minimum Load<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<td>\n<p>2mA\/DC Power<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Leakage Current<\/p>\n<\/td>\n<td>\n<p>\uff1c0.1mA\/30VDC<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Maximum<\/p>\n<p>Output<\/p>\n<p>Delay<\/p>\n<p>Time<\/p>\n<\/td>\n<td>\n<p>ON &gt; OFF<\/p>\n<\/td>\n<td>\n<p>\uff1c10\u03bcS<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>10ms<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF &gt; ON<\/p>\n<\/td>\n<td>\n<p>\uff1c40\u03bcS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Over Current Protection<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Photocoupler Isolation, 500VAC, 1 minute<\/p>\n<\/td>\n<td>\n<p>Electromagnetic Isolation, 500VAC, 1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>SINK \/SOURCE Type<\/p>\n<\/td>\n<td>\n<p>Choose SINK\/SOURCE by models and non-exchangeable<\/p>\n<\/td>\n<td>\n<p>Bilateral device, can be arbitrarily set to SINK\/SOURCE output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M16X Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>X1~X16 Input Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y1~Y16 output Indicator<\/p>\n<\/td>\n<td>\n<p>ON: green light<\/p>\n<p>OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<ul>\n<li>Wiring of single-end common SINK input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-010.png\" \/><\/p>\n<p>Wiring of single-end common SINK input<\/p>\n<ul>\n<li>Wiring of single-end common SOURCE input<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-011.png\" \/><\/p>\n<p>Wiring of single-end common SOURCE input<\/p>\n<ul>\n<li>Transistor Single-End SINK Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-012.png\" \/><\/p>\n<p>Transistor Single-End SINK Output<\/p>\n<ul>\n<li>Transistor Single-End SOURCE Output<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-013.png\" \/><\/p>\n<p>Transistor Single-End SOURCE Output<\/p>\n<h3>10-4 Analog Input Expansion Module Specifications<\/h3>\n<p>If the Analog input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-4-1 M04AD Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-014.png\" \/><\/p>\n<p>M04AD Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04AD Technical Specification Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M04AD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>High Speed: 300us\/Ch<\/p>\n<p>Medium Speed: 500us\/Ch<\/p>\n<p>Low Speed: 1ms\/Ch<\/p>\n<p>50Hz filter: 80ms\/Ch<\/p>\n<p>60Hz filter: 68ms\/Ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog input range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>1.22mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.305mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.244mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>-20mA~+20mA<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>2.44uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>1.22uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.976uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.2% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1M\u2126 Current\uff1a250\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog input channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04AD Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-015.png\" \/><\/p>\n<p>M04AD Wiring<\/p>\n<h4>10-4-2 M04ADS Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-016.png\" \/><\/p>\n<p>M04ADS Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04ADS Technical Specification Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M04ADS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Medium Speed: 500us\/Ch<\/p>\n<p>Low Speed: 1ms\/Ch<\/p>\n<p>50Hz filter: 80ms\/Ch<\/p>\n<p>60Hz filter: 68ms\/Ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog input range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.3mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.15mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.15mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.075mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.06mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>-20mA~+20mA<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.6uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.3uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.24uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.2% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1M\u2126 Current\uff1a250\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog input channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04ADS Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u5716\u8868, \u6587\u5b57, \u65b9\u6848, \u5de5\u7a0b\u88fd\u5716 \u7684\u5716\u7247\n\nAI \u7522\u751f\u7684\u5167\u5bb9\u53ef\u80fd\u4e0d\u6b63\u78ba\u3002\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-017.png\" \/><\/p>\n<p>M04ADS Wiring<\/p>\n<h4>10-4-3 M08ADS Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-018.png\" \/><\/p>\n<p>M08ADS Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M08ADS Technical Specification Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M08ADS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Medium Speed: 500us\/Ch<\/p>\n<p>Low Speed: 1ms\/Ch<\/p>\n<p>50Hz filter: 80ms\/Ch<\/p>\n<p>60Hz filter: 68ms\/Ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog input range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.3mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.15mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.15mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.075mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.06mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>-20mA~+20mA<\/p>\n<\/td>\n<td>\n<p>-32768~32767<\/p>\n<\/td>\n<td>\n<p>0.6uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.3uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~65535<\/p>\n<\/td>\n<td>\n<p>0.24uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.2% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1M\u2126 Current\uff1a250\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog input channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04ADS Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u5716\u8868, \u6587\u5b57, \u65b9\u6848, \u5de5\u7a0b\u88fd\u5716 \u7684\u5716\u7247\n\nAI \u7522\u751f\u7684\u5167\u5bb9\u53ef\u80fd\u4e0d\u6b63\u78ba\u3002\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-019.png\" \/><\/p>\n<p>M08ADS Wiring<\/p>\n<h4>10-4-4 M04ADR Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-020.png\" \/><\/p>\n<p>M04ADR Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04ADR Technical Specification<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M04ADR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>High Speed: 1.5ms\/Ch.<\/p>\n<p>Medium Speed: 4ms\/Ch.<\/p>\n<p>Low Speed: 15ms\/Ch.<\/p>\n<p>50Hz Filter: 80ms\/Ch.<\/p>\n<p>60Hz Filter: 68ms\/Ch.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog input range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-80000~80000<\/p>\n<\/td>\n<td>\n<p>0.125mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-80000~80000<\/p>\n<\/td>\n<td>\n<p>0.0625mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~80000<\/p>\n<\/td>\n<td>\n<p>0.125mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~80000<\/p>\n<\/td>\n<td>\n<p>0.0625mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~80000<\/p>\n<\/td>\n<td>\n<p>0.05mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>-20mA~+20mA<\/p>\n<\/td>\n<td>\n<p>-80000~80000<\/p>\n<\/td>\n<td>\n<p>0.25uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~80000<\/p>\n<\/td>\n<td>\n<p>0.25uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~80000<\/p>\n<\/td>\n<td>\n<p>0.2uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1M\u2126 Current\uff1a250\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog input channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04ADR Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-021.png\" \/><\/p>\n<p>M04ADR Wiring<\/p>\n<h3>10-5 Analog Output Expansion Module Specifications<\/h3>\n<p>If the Analog output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-5-1 M04DA Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-022.png\" \/><\/p>\n<p>M04DA Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04DA Technical Specification<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M04DA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1ms\/channel<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>Analog output characteristics and resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog output range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>1.22mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.305mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.244mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>1.22\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.976\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.2% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.2% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DA Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>16-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Minimum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1k\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Current\uff1a500\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Hardware maximum output<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>-10.2~+10.2V<\/p>\n<p>-5.1~+5.1V<\/p>\n<p>-0.2~10.2V<\/p>\n<p>-0.1~5.1V<\/p>\n<p>0.9~5.1V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0~20.2mA<\/p>\n<p>4~20.2mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog output and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog output channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04DA Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DAC Indicator<\/p>\n<\/td>\n<td>\n<p>DAC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-023.png\" \/><\/p>\n<p>M04DA Wiring<\/p>\n<h4>10-5-2 M04DAR Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-024.png\" \/><\/p>\n<p>M04DAR Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04DAR Technical Specification<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>model<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M04DAR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Point<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0.5ms\/channel<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>Analog output characteristics and resolution<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog output range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td>\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-27000~27000<\/p>\n<\/td>\n<td>\n<p>0.37mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-27000~27000<\/p>\n<\/td>\n<td>\n<p>0.185mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~27000<\/p>\n<\/td>\n<td>\n<p>0.37mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~27000<\/p>\n<\/td>\n<td>\n<p>0.185mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~27000<\/p>\n<\/td>\n<td>\n<p>0.48mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td>\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~27000<\/p>\n<\/td>\n<td>\n<p>0.74\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~27000<\/p>\n<\/td>\n<td>\n<p>0.592\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.05% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.3% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>\u00b10.05% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.3% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DA Converter<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>16-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Minimum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Voltage\uff1a1k\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum load impedance<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Current\uff1a500\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>hardware output<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>-10.2~+10.2V<\/p>\n<p>-5.1~+5.1V<\/p>\n<p>-0.2~10.2V<\/p>\n<p>-0.1~5.1V<\/p>\n<p>0.9~5.1V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0~20.2mA<\/p>\n<p>4~20.2mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Between analog output and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog output channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04DAR Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DAC Indicator<\/p>\n<\/td>\n<td>\n<p>DAC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-025.png\" \/><\/p>\n<p>M04DAR Wiring<\/p>\n<h3>10-6 Analog Input\/Output Combo Expansion Module Specifications<\/h3>\n<p>If the Analog input\/output point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-6-1 M0202AH Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-026.png\" \/><\/p>\n<p>M0202AH Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M0202AH Technical Specification<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>M0202AH<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\">\n<p>Input Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Point<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>High Speed: 300us\/Ch<\/p>\n<p>Medium Speed: 500us\/Ch<\/p>\n<p>Low Speed: 1ms\/Ch<\/p>\n<p>50Hz filter: 80ms\/Ch<\/p>\n<p>60Hz filter: 68ms\/Ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\">\n<p>Analog Input Characteristics and Resolution<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Analog input range<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-10~+10V<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>1.22mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>-5~+5V<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0~10V<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0~5V<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.305mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>1~5V<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.244mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-20mA~+20mA<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>2.44uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0~20mA<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>1.22uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>4~20mA<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.976uA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.2% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>\u00b10.2% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Resistance<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Voltage\uff1a1M\u2126 Current\uff1a250\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hardware maximum input<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Voltage\uff1a\uff0d15V\uff5e\uff0b15V Current\uff1a-30mA~+30mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\">\n<p>Output Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Point<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion speed<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>1ms\/channel<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>Analog output characteristics and resolution<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Analog output range<\/p>\n<\/td>\n<td>\n<p>Data<\/p>\n<\/td>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"5\">\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>-10~+10V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>1.22mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>-5~+5V<\/p>\n<\/td>\n<td>\n<p>-8192~8191<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0~10V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.61mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.305mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>1~5V<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.244mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>1.22\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>4~20mA<\/p>\n<\/td>\n<td>\n<p>0~16383<\/p>\n<\/td>\n<td>\n<p>0.976\u03bcA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Conversion precision<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u00b10.2% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u00b10.2% (25\u2103\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0~55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DA Converter<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Minimum load impedance<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Voltage\uff1a1k\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum load impedance<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Current\uff1a500\u2126<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Hardware Maximum output<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Voltage<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>-10.2~+10.2V<\/p>\n<p>-5.1~+5.1V<\/p>\n<p>-0.2~10.2V<\/p>\n<p>-0.1~5.1V<\/p>\n<p>0.9~5.1V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Current<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>0~20.2mA<\/p>\n<p>4~20.2mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\">\n<p>Common Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Between analog input\/output and CPU\uff1ainsulated\uff08Digital isolators, transformers\uff09<\/p>\n<p>Between analog input\/output channels\uff1anon-insulated<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M0202AH Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC\/DAC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC\/DAC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-027.png\" \/><\/p>\n<p>M0202AH Wiring<\/p>\n<h3>10-7 Temperature Expansion Module Specifications<\/h3>\n<p>If the temperature input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-7-1 M04TC Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-028.png\" \/><\/p>\n<p>M04TC Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04TC Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M04TC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<td>\n<p>0.1\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>High Speed:200ms\/ch<\/p>\n<p>Standard:400ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperature sensor type<\/p>\n<\/td>\n<td>\n<p>K, J, E, T, R, B, N, S, mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.5% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b11% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating mode<\/p>\n<\/td>\n<td>\n<p>PID Control<\/p>\n<p>ON\/OFF Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control cycle<\/p>\n<\/td>\n<td>\n<p>0.1~30 Second+ 1 Scan time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tuning<\/p>\n<\/td>\n<td>\n<p>PID Auto Tuning<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04TC Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-029.png\" \/><\/p>\n<p>M04TC Wiring<\/p>\n<h4>10-7-2 M04TCR Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-030.png\" \/><\/p>\n<p>M04TCR Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04TCR Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M04TCR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<td>\n<p>0.1\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>High Speed:100ms\/ch<\/p>\n<p>Standard:200ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperature sensor type<\/p>\n<\/td>\n<td>\n<p>K, J, E, T, R, B, N, S, mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.2% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating mode<\/p>\n<\/td>\n<td>\n<p>PID Control<\/p>\n<p>ON\/OFF Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control cycle<\/p>\n<\/td>\n<td>\n<p>0.1~30 Second+ 1 Scan time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tuning<\/p>\n<\/td>\n<td>\n<p>PID Auto Tuning<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04TCR Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-031.png\" \/><\/p>\n<p>M04TCR Wiring<\/p>\n<h4>10-7-3 M04RTD Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u6587\u5b57, \u5716\u8868, \u5beb\u751f \u7684\u5716\u7247\n\n\u81ea\u52d5\u7522\u751f\u7684\u63cf\u8ff0\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-032.png\" \/><\/p>\n<p>M04RTD Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M04RTD Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M04RTD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<td>\n<p>0.1\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>100ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperature sensor type<\/p>\n<\/td>\n<td>\n<p>Pt100 \/ Pt1000: (-200~850\u2103)<\/p>\n<p>JPt100 \/ JPt1000: (-200~600\u2103)<\/p>\n<p>PT100(1000) &#8211; DIN EN 60751<\/p>\n<p>JPT100(1000) &#8211; JIS C 1609-1981<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating mode<\/p>\n<\/td>\n<td>\n<p>PID Control<\/p>\n<p>ON\/OFF Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control cycle<\/p>\n<\/td>\n<td>\n<p>0.1~30 Second+ 1 Scan time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tuning<\/p>\n<\/td>\n<td>\n<p>PID Auto Tuning<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M04RTD Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-033.png\" \/><\/p>\n<p>M04RTD Wiring<\/p>\n<h3>10-8 Temperature Combo Expansion Module Specifications<\/h3>\n<p>If the temperature input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-8-1 M0202TH Specification<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-034.png\" \/><\/p>\n<p>M0202TH Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M0202TH Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M0202TH<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>TC Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<td>\n<p>0.1\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>High Speed:200ms\/ch<\/p>\n<p>Standard:400ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperature sensor type<\/p>\n<\/td>\n<td>\n<p>K, J, E, T, R, B, N, S, mV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.5% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b11% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>RTD Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution<\/p>\n<\/td>\n<td>\n<p>0.1\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>100ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Temperature sensor type<\/p>\n<\/td>\n<td>\n<p>Pt-100, Pt-1000 (-200~850\u2103)<\/p>\n<p>JPt-100, JPt-1000 (-200~600\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.1% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.5% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Common Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating mode<\/p>\n<\/td>\n<td>\n<p>PID Control<\/p>\n<p>ON\/OFF Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control cycle<\/p>\n<\/td>\n<td>\n<p>0.1~30 Second<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tuning<\/p>\n<\/td>\n<td>\n<p>PID Auto Tuning<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M0202TH Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-035.png\" \/><\/p>\n<p>M0202TH Wiring<\/p>\n<h3>10-9 Load Cell Expansion Module Specifications<\/h3>\n<p>If the Load Cell input point of the M Series CPU module is not enough for a specific application, then can expand it with the additional expansion modules.<\/p>\n<h4>10-9-1 M02LC Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-036.png\" \/><\/p>\n<p>M02LC Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M02LC Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M02LC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Excitation Voltage<\/p>\n<\/td>\n<td>\n<p>5VDC\u00b15%, 60mA <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sensor Type<\/p>\n<\/td>\n<td>\n<p>4-wire or 6-wire Load Cell<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of Sensor Connection<\/p>\n<\/td>\n<td>\n<p>4 * 350\u03a9 Sensor<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sensitivity<\/p>\n<\/td>\n<td>\n<p>\u00b11.0mV\/V<br \/>\u00b12.0mV\/V<br \/>\u00b13.0mV\/V<br \/>\u00b14.0mV\/V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter Resolution<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.5% (25\u00b0C\u00b15\u2103)<br \/>\u00b11% (0\uff5e55\u2103)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Zero Drift<\/p>\n<\/td>\n<td>\n<p>0.2uV\/\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gain Drift<\/p>\n<\/td>\n<td>\n<p>\u00b110ppm\/\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>High Speed :2ms\/ch. (only Use Single Point)<br \/>Standard:10ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M02LC Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-037.png\" \/><\/p>\n<p>M02LC Wiring<\/p>\n<h4>10-9-2 M02LCR Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-038.png\" \/><\/p>\n<p>M02LC Appearance<\/p>\n<p>Technical Specification<\/p>\n<p>M02LCR Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>M02LCR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Points<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Excitation Voltage<\/p>\n<\/td>\n<td>\n<p>5VDC\u00b15%, 60mA <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sensor Type<\/p>\n<\/td>\n<td>\n<p>4-wire or 6-wire Load Cell<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Number of Sensor Connection<\/p>\n<\/td>\n<td>\n<p>4 * 350\u03a9 Sensor<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sensitivity<\/p>\n<\/td>\n<td>\n<p>\u00b11.0mV\/V<br \/>\u00b12.0mV\/V<br \/>\u00b13.0mV\/V<br \/>\u00b14.0mV\/V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AD Converter Resolution<\/p>\n<\/td>\n<td>\n<p>24-Bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion precision<\/p>\n<\/td>\n<td>\n<p>\u00b10.01% (25\u00b0C\u00b15\u2103)<\/p>\n<p>\u00b10.4% (0~50\u00b0C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Zero Drift<\/p>\n<\/td>\n<td>\n<p>0.2uV\/\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gain Drift<\/p>\n<\/td>\n<td>\n<p>\u00b110ppm\/\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sampling cycle<\/p>\n<\/td>\n<td>\n<p>Standard:10ms\/ch<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation<\/p>\n<\/td>\n<td>\n<p>Between analog input and CPU\uff1ainsulated\uff08Digital isolators, Transformer\uff09<\/p>\n<p>Between analog input channels\uff1ainsulated\uff08optocoupler isolator\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>M02LCR Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR Indicator<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN Indicator<\/p>\n<\/td>\n<td>\n<p>Running: green light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC Indicator<\/p>\n<\/td>\n<td>\n<p>ADC Converting: yellow light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM Indicator<\/p>\n<\/td>\n<td>\n<p>On Alert: red light<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR Indicator<\/p>\n<\/td>\n<td>\n<p>In ERROR: red light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Wiring<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-039.png\" \/><\/p>\n<p>M02LCR Wiring<\/p>\n<h3>10-10 Repeater Expansion Module Specifications<\/h3>\n<p>If the power of the Power module is not enough for expansion module, then can expand it with the additional repeater Expansion module.<\/p>\n<h4>10-10-1 MRPWE-AC Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" alt=\"\u4e00\u5f35\u542b\u6709 \u6587\u5b57, \u5716\u8868, \u65b9\u6848, \u5de5\u7a0b\u88fd\u5716 \u7684\u5716\u7247\n\n\u81ea\u52d5\u7522\u751f\u7684\u63cf\u8ff0\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-040.png\" \/><\/p>\n<p>MRPWE-AC Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MRPWE-AC Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MRPWE-AC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\">\n<p>Input<\/p>\n<\/td>\n<td>\n<p>Input voltage<\/p>\n<\/td>\n<td>\n<p>100~240VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input frequency<\/p>\n<\/td>\n<td>\n<p>50\/60Hz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum input current<\/p>\n<\/td>\n<td>\n<p>1A max.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Inrush current\uff08cold start\uff09<\/p>\n<\/td>\n<td>\n<p>22A\/115Vac (44A\/230Vac)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand voltage<\/p>\n<\/td>\n<td>\n<p>3,000 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC<\/p>\n<p>(Secondary-PE)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Insulation resistance<\/p>\n<\/td>\n<td>\n<p>&gt;100M\u03a9\/500VDC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Fuse<\/p>\n<\/td>\n<td>\n<p>2A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hold-up time<\/p>\n<\/td>\n<td>\n<p>&gt;15ms\/ 115VAC\uff0c&gt;60ms\/ 220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Isolation Type<\/p>\n<\/td>\n<td>\n<p>Transformer\/ Photocoupler Isolation\uff0c1500VAC\/1 minute<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power indication<\/p>\n<\/td>\n<td>\n<p>LED (green)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>output<\/p>\n<\/td>\n<td>\n<p>Rated output power<\/p>\n<\/td>\n<td>\n<p>48W (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rated output current<\/p>\n<\/td>\n<td>\n<p>2A (Shared CPU dedicated power supply and external Sensor power supply)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output voltage range<\/p>\n<\/td>\n<td>\n<p>24VDC\u00b11%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conversion efficiency<\/p>\n<\/td>\n<td>\n<p>86%\/110VAC\uff0c87%\/220VAC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Protection<\/p>\n<\/td>\n<td>\n<p>Overvoltage protection<\/p>\n<\/td>\n<td>\n<p>Latching overvoltage protection, re-power on to recover<\/p>\n<p>34V~36V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Overcurrent protection<\/p>\n<\/td>\n<td>\n<p>Method: Foldback overload protection, automatically recover when overload is removed<\/p>\n<p>101%~133% rated output power<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Certification<\/p>\n<\/td>\n<td>\n<p>CE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MRPWE-AC Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>10-11 I\/O Bus extension module Specifications<\/h3>\n<p>If extension expansion module to 2nd row, then can expand it with the additional I\/O Bus extension module to Expansion module.<\/p>\n<h4>10-11-1 MRGH Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-041.png\" \/><\/p>\n<p>MRGH Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MRGH Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MRGH<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Function<\/p>\n<\/td>\n<td>\n<p>The head module must be used with the MRGT (tail). Each row can expand up to 16 Local I\/O expansion modules, with a maximum of 6 rows (6 sections, racks), for a total of 64 expansion modules.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Certification<\/p>\n<\/td>\n<td>\n<p>CE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MRGH Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>10-11-2 MRGT Specifications<\/h4>\n<p>Appearance and Function<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m02-en-10\/mplc-m02-en-10-042.png\" \/><\/p>\n<p>MRGT Appearance<\/p>\n<p>Technical Specifications<\/p>\n<p>MRGT Technical Specifications Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Technical Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>MRGT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Function<\/p>\n<\/td>\n<td>\n<p>The tail module must be used with the MRGH (head). Each row can expand up to 16 Local I\/O expansion modules, with a maximum of 6 rows (6 sections, racks), for a total of 64 expansion modules.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operating Ambient Temperature<\/p>\n<\/td>\n<td>\n<p>0~55\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Relative Humidity<\/p>\n<\/td>\n<td>\n<p>20 ~ 90% (non-condensing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Altitude<\/p>\n<\/td>\n<td>\n<p>\u22662000m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration <\/p>\n<p>(Fixed by DIN RAIL)<\/p>\n<\/td>\n<td>\n<p>5~8.4Hz Amplitude: 3.5mm<\/p>\n<p>8.4~150Hz Constant acceleration:19.6m\/s^2(2G)<\/p>\n<p>10G, 10 times each along the 3 axes (IEC61131-2 Standard)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock<\/p>\n<\/td>\n<td>\n<p>10G, 3 times each along the 3 axes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise Suppression<\/p>\n<\/td>\n<td>\n<p>1500Vp-p\uff0cWidth 1us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Withstand Voltage<\/p>\n<\/td>\n<td>\n<p>1500 VAC 1 minute (Between power terminals and input\/output terminals, and between all external terminals and the housing)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Certification<\/p>\n<\/td>\n<td>\n<p>CE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Status Indicator<\/p>\n<p>MRGT Status Indicator Table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR LED<\/p>\n<\/td>\n<td>\n<p>Power ON: green light<\/p>\n<p>Power OFF: no light<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Chapter 10 Local I\/O Expansion Modules Specifications 1 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[],"class_list":["post-3195","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m02"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3195"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3195\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3195"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3195"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}