{"id":3221,"date":"2026-11-17T18:38:37","date_gmt":"2026-11-17T10:38:37","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-14\/"},"modified":"2026-11-17T18:38:37","modified_gmt":"2026-11-17T10:38:37","slug":"mplc-m03-en-14","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-14\/","title":{"rendered":"Chapter 14 Updating CPU Unit and module firmware"},"content":{"rendered":"<h3>14-1  Software Updating Process<\/h3>\n<h4>14-1-1 CPU Unit                                                                  <\/h4>\n<p>Notice<\/p>\n<ul>\n<li>Applicable to all CPU Unit models.<\/li>\n<li>During the updating process, do not attempt to shut down the power or remove the USB or the network plug.<\/li>\n<li>Repeat the steps if failure occurs when updating the modules.<\/li>\n<li>If unexpected update failures cause the CPU Unit to fail to boot, please refer to Section 14-2-1.<\/li>\n<\/ul>\n<p><strong>Step 1<\/strong><\/p>\n<p>Set the Dip Switch of the target CPU Unit to the \u201cSTOP\u201d position. Connect your computer and computer via USB or network cable, and use the &quot;PLC Status&quot; in the UperLogic software to confirm the current version. The PLC firmware version in the picture: V0.2.90, MC firmware version V0.5.21.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-001.png\" \/><\/p>\n<p>Figure 92 Information of firmware version<\/p>\n<p><strong>Step 2<\/strong><\/p>\n<p>Select \u201cPLC Setting\u201d and then click the option in the lower side \u201cFirmware Update\u201d.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-002.png\" \/><\/p>\n<p>Figure 93 Selection of firmware update<\/p>\n<p><strong>Step 3<\/strong><\/p>\n<p>In the pop-up window, select the OS file to be updated. <\/p>\n<p>Per the figure, the \u201cm_plc_HW01_enc_v0_3_2_v0_5_22_00000000.os\u201d file is selected. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-003.png\" \/><\/p>\n<p>Figure 94 Review and select PLC firmware file<\/p>\n<p><strong>Step 4<\/strong><\/p>\n<p>After opening, the system will start the update and the progress bar will be displayed during the update process. After that, a notification will be shown.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-004.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-005.jpg\" \/><\/p>\n<p>Figure 95 Notification of update progress bar and update success<\/p>\n<p><strong>Step 5<\/strong><\/p>\n<p>After being updated, it can be used normally without restarting the power and then click \u201cPLC status\u201d to confirm that the version has been updated.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-006.png\" \/><\/p>\n<p>Figure 96 Update success of firmware version<\/p>\n<h4>14-1-2 Expansion Module                                                     <\/h4>\n<p>Notice<\/p>\n<ul>\n<li>Applicable to all expansion modules.<\/li>\n<li>During the updating process, do not attempt to shut down the power or remove the USB or the network plug.<\/li>\n<li>Repeat the steps if failure occurs when updating the modules.<\/li>\n<li>If unexpected update failures cause the CPU Unit to fail to boot, please refer to Section 14-2-2.<\/li>\n<\/ul>\n<p><strong>Step 1<\/strong><\/p>\n<p>Set the Dip Switch of the target CPU Unit to the \u201cSTOP\u201d position. Connect your CPU Unit computer and computer via USB or network cable.<\/p>\n<p><strong>Step 2<\/strong><\/p>\n<p><strong>Select \u201cUpload\u201d<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-007.png\" \/><strong>\t<\/strong><\/p>\n<p>Figure 99 Select \u201cUpload\u201d<\/p>\n<p><strong>Step 3<\/strong><\/p>\n<p>Select \u201cExpansion Data\u201d and \u201cMotion Program\u201d to upload.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-008.png\" \/><\/p>\n<p>Figure 102 Upload expansion and motion data<\/p>\n<p><strong>Step 4<\/strong><\/p>\n<p>After selecting \u201cOnline Monitor\u201d, please confirm the PLC is under shutdown status in order to update the expansion module firmware.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-009.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-010.png\" \/><\/p>\n<p>Figure 103 Online monitoring<\/p>\n<p><strong>Step 5<\/strong><\/p>\n<p><strong>Click \u201cProject\u201d-&gt;Equipment picture.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-011.png\" \/><\/p>\n<p>Figure 104 Find the equipment picture in \u201cProject\u201d<\/p>\n<p><strong>Step 6<\/strong><\/p>\n<p>Select the module to be upgraded. (Here takes M04AD as an example)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-012.png\" \/><\/p>\n<p>Figure 105 Select the target module<\/p>\n<p><strong>Step 7<\/strong><\/p>\n<p><strong>In the pop-up window, select the firmware version and then click \u201cUpgrade\u201d.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-013.png\" \/><\/p>\n<p>Figure 106 Click the module firmware to be upgraded<\/p>\n<p><strong>Step 8<\/strong><\/p>\n<p>In the pop-up window, tick the OS module to be updated until all of the modules that will be updated are selected.<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-014.png\" \/><\/p>\n<p>Figure 107 Tick the module to be upgraded<\/p>\n<p><strong>Step 9<\/strong><\/p>\n<p>Click in the column of all modules to update the OS to select the file<\/p>\n<p><strong>.<\/strong><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-015.png\" \/><\/p>\n<p>Figure 108 Select firmware file<\/p>\n<p><strong>Step 10<\/strong><\/p>\n<p>Click \u201cUpgrade\u201d. Do not attempt to shut down the power or remove the USB or the network wire before new window pops up.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-016.png\" \/><\/p>\n<p>Figure 110 Execution of upgrading<\/p>\n<p>The following window will pop up after completing the up, notifying that the update has been done.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m03-en-14\/mplc-m03-en-14-017.png\" \/><\/p>\n<p>Figure 111 Notifying window after upgrade<\/p>\n<h3>14-2  Update Firmware by Memory Card                                         <\/h3>\n<p>Notice<\/p>\n<p>&#8211;\tDuring the updating process, do not attempt to shut down the power .<\/p>\n<p>&#8211;\tRepeat the steps if failure occurs when updating the modules.<\/p>\n<ul>\n<li>Firmware rescue for expansion module can only be performed on one module at a time.<\/li>\n<\/ul>\n<p><strong>[CPU Unit]<\/strong><\/p>\n<p><strong>Firmware Update via Memory Card<\/strong><\/p>\n<p><strong>Step 1<\/strong> Select OS Update for PLC and Write the OS file to the memory card using UperLogic.<\/p>\n<p><strong>Step 2<\/strong> Confirm that the CPU Unit is in STOP mode and power on the CPU Unit.<\/p>\n<p><strong>Step 3<\/strong> Wait until the RUN\/STOP LED flashes normally, then insert the memory card.<\/p>\n<p><strong>Step 4<\/strong> Check the LED status. When updating, the memory card execution light will flash, and the flashing ends and the normal LED display returns to indicate that the update is complete.<\/p>\n<p><strong>Step 5<\/strong> Use UperLogic software to connect to the CPU Unit and confirm.<\/p>\n<p><strong>Firmware Rescue via Memory Card<\/strong><\/p>\n<p><strong>Step 1<\/strong> Select OS Rescue for PLC and Write the OS file to the memory card using UperLogic.<\/p>\n<p><strong>Step 2<\/strong> Insert the memory card.<\/p>\n<p><strong>Step 3<\/strong> Confirm that the CPU Unit is in STOP mode and power on the CPU Unit.<\/p>\n<p><strong>Step 4<\/strong> Check the LED status. When updating, the memory card execution light will flash, and the flashing ends and the normal LED display returns to indicate that the update is complete.<\/p>\n<p><strong>Step 5<\/strong> Use UperLogic software to connect to the CPU Unit and confirm.<\/p>\n<p><strong>[Expansion Module]<\/strong><\/p>\n<p><strong>Firmware Update via Memory Card<\/strong><\/p>\n<p><strong>Step 1<\/strong> Select OS Update for Expansion and write the OS file to the memory card using UperLogic.<\/p>\n<p><strong>Step 2<\/strong> Attach the expansion modules to the CPU Unit as you would like.<\/p>\n<p><strong>Step 3<\/strong> Confirm that the CPU Unit is in STOP mode and power on the CPU Unit.<\/p>\n<p><strong>Step 4<\/strong> Wait until the RUN\/STOP LED flashes normally, then insert the memory card.<\/p>\n<p><strong>Step 5<\/strong> Check the LED status. When updating, the memory card execution light will flash, and the flashing ends and the normal LED display returns to indicate that the update is complete.<\/p>\n<p><strong>Step 6<\/strong> Use UperLogic software to connect to the CPU Unit and confirm the version. All modules of the same type shall be updated successfully.<\/p>\n<p><strong>Firmware Rescue via Memory Card<\/strong><\/p>\n<p><strong>Step 1<\/strong> Select OS Rescue for Expansion and write the OS file to the memory card using UperLogic.<\/p>\n<p><strong>Step 2<\/strong> Attach only one expansion module to rescue at the first position to the CPU Unit<\/p>\n<p><strong>Step 3<\/strong> Confirm that the CPU Unit is in STOP mode and power on the CPU Unit.<\/p>\n<p><strong>Step 4<\/strong> Wait until the ERR LED is lit, then insert the memory card.<\/p>\n<p><strong>Step 5<\/strong> Check the LED status. When updating, the memory card execution light will flash, and the flashing ends and the normal LED display returns to indicate that the update is complete.<\/p>\n<p><strong>Step 6<\/strong> Use UperLogic software to connect to the CPU Unit and confirm that the module has been rescued successfully.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>14-1 Software Updating Process 14-1-1 CPU Unit Notice A [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-3221","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m03"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3221","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3221"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3221\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3221"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3221"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3221"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}