{"id":3222,"date":"2026-11-17T18:38:38","date_gmt":"2026-11-17T10:38:38","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-15\/"},"modified":"2026-11-17T18:38:38","modified_gmt":"2026-11-17T10:38:38","slug":"mplc-m03-en-15","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-15\/","title":{"rendered":"Appendix A CPU Unit Memory"},"content":{"rendered":"<ul>\n<li>This configuration is the factory setting<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"4\">\n<p>Category<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Specification<\/p>\n<\/td>\n<td>\n<p>Notes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>\uff22\uff29\uff34<\/p>\n<\/td>\n<td>\n<p>X<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Digital Input (DI) <\/p>\n<p>(Maximum 2048 points)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>X0\uff5eX1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external digital input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Digital Output (DO)<\/p>\n<p> (Maximum 2048 points)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Y0\uff5eY1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external digital input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>TR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Temporary relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>TR0\uff5eTR31(32)<\/p>\n<p>(Reserved by the system)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>M<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Internal relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M0\uff5eM9119 (9120) <\/p>\n<\/td>\n<td>\n<p>M0~M9119 can be planned as retentive or non-retentive relays.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Special relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>M9120\uff5eM25599 (16480)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>S<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Stepping relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>S0\uff5eS3103 (3104)<\/p>\n<\/td>\n<td>\n<p>S0\uff5eS3103 can be planned as retentive <strong>or<\/strong> non-retentive relays.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>T<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Timer relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>T0\uff5eT1023 (1024)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>C<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Counter relay<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>C0\uff5eC1279 (1280)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"13\">\n<p>\uff37\uff2f\uff32\uff24<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>TMR<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Timer present value register<\/p>\n<\/td>\n<td>\n<p>0.01S time base<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>T0\uff5eT255 (256) *<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>T0\uff5eT1023 can flexibly plan the number of each time base<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0.1S time base<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>T256\uff5eT511 (256) *<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1S time base<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>T512\uff5eT1023 (512) *<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>CTR<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Counter present value register<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<p>BIT<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>C0\uff5eC1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Can be planned as retentive or non-retentive relays.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32<\/p>\n<p>BIT<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>C024\uff5eC1279 (256) <\/p>\n<\/td>\n<td>\n<p>Can be planned as retentive or non-retentive relays.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>HR<\/p>\n<p>DR<\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Data register<\/p>\n<\/td>\n<td>\n<p>Retentive<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R0\uff5eR14999 (15000)<\/p>\n<p>* Note: Can be planned non-retentive relays.<br \/>D0\uff5eD7999 (8000)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Non-Retentive<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R15000\uff5eR34767 (19768)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>HR<\/p>\n<p>ROR<\/p>\n<\/td>\n<td>\n<p>Retentive<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R43224\uff5eR47319 (4096) * Note: <\/p>\n<p>When it is not planned as ROR, it can be used as a general register<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Read only register<\/p>\n<p>(ROR)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R43224\uff5eR47319 Can be planned as read only register, factory setting is 0*<\/p>\n<\/td>\n<td>\n<p>Stored in the ROR area, does not occupy the program capacity<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>File register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>F0\uff5eF65535(65536)<\/p>\n<p>* Note: Requires access through dedicated instruction<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>IR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Input register (AI)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R34768\uff5eR34895 (128)<\/p>\n<\/td>\n<td>\n<p>Corresponds to external analog input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Output register (AO)<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35024\uff5eR35151 (128)<\/p>\n<\/td>\n<td>\n<p>Corresponds to external analog output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>SR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>System special register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35280\uff5eR43223 (7944)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\"><\/td>\n<td rowspan=\"7\">\n<p>Special Register<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0.1ms timer HST register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35451~R35466(16)<\/p>\n<\/td>\n<td rowspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>1ms timer HST register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35435~R35442(8)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>10ms timer LTM register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35443~R35450(8)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0.1ms timing HSTA loop count<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>DR35467<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>High-speed counter register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35280~R35311(32)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>RTC register<\/p>\n<\/td>\n<td>\n<p>R35312<\/p>\n<p>(sec)<\/p>\n<\/td>\n<td>\n<p>R35313 (min)<\/p>\n<\/td>\n<td>\n<p>R35314 (h)<\/p>\n<\/td>\n<td>\n<p>R35315<\/p>\n<p>(day)<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35316<\/p>\n<p>(month)<\/p>\n<\/td>\n<td>\n<p>R35317 (year)<\/p>\n<\/td>\n<td>\n<p>R35318 (week)<\/p>\n<\/td>\n<td>\n<p>R35319 <\/p>\n<p>(h\uff0bmin)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>FR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>File register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>F0~F65535(65536)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>XR<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Index register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>V: R43214<\/p>\n<p>Z: R43216<\/p>\n<p>P0\uff5eP9 : <\/p>\n<p>R43194, R43196, R43198, R43200, R43202, R43204, R43206, R43208, R43210, R43212<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Table 92 M-Series PLC memory<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This configuration is the factory setting Category Spec [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-3222","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m03"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3222","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3222"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3222\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3222"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3222"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3222"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}