{"id":3223,"date":"2026-11-17T18:38:40","date_gmt":"2026-11-17T10:38:40","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-16\/"},"modified":"2026-11-17T18:38:40","modified_gmt":"2026-11-17T10:38:40","slug":"mplc-m03-en-16","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m03-en-16\/","title":{"rendered":"Appendix B System Error Detection"},"content":{"rendered":"<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>ERR1\/ERR2 LED<\/p>\n<\/td>\n<td>\n<p>SR\/MASK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Not enough memory capacity<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserve<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Initialization error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserve<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserve<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System stack error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System check code error instruction<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0004<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power-on detection for power-off operation<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System check code error instruction<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35362\/0x3E00<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion module detection error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0001<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion module configuration error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0002<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The number of expansion modules does not match the CPU Unit project<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0004<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion module I\/O points out of range<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0008<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The number of expansion modules out of range<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion control unit queue error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0080<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion control unit overflow error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion control unit emergency stop<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Watchdog restart detection<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0010<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Illegal memory card detection instruction<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0010<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Memory card operation error detection<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0020<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PLC ID dose not match PROG ID<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0040<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The application exceeds the capabilities of this CPU<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0800<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System service error instruction<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x8000<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Item ERR1\/ERR2 LED SR\/MASK Not enough memory capacity O [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-3223","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m03"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3223"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3223\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3223"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3223"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}