{"id":3248,"date":"2026-11-17T18:39:14","date_gmt":"2026-11-17T10:39:14","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m06-en-02\/"},"modified":"2026-11-17T18:39:14","modified_gmt":"2026-11-17T10:39:14","slug":"mplc-m06-en-02","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m06-en-02\/","title":{"rendered":"Chapter 2 Motion Parameters and Status"},"content":{"rendered":"<p><strong>Motion Parameters and Status<\/strong><\/p>\n<p><strong>(Special Register and Relay)<\/strong><\/p>\n<p>This section will introduce the layout of memory in the M-PLC and the details of the register. The scope of Motion Registers starts from R36880 for using as the starting register, and the scope of Relays starts from M10512. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p><strong>Type<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Start Address<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Size per axis or group<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion System Register (word)<\/p>\n<\/td>\n<td>\n<p>R<\/p>\n<\/td>\n<td>\n<p>R36880<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Axis Register (word)<\/p>\n<\/td>\n<td>\n<p>R<\/p>\n<\/td>\n<td>\n<p>R36980<\/p>\n<\/td>\n<td>\n<p>150<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion System Relay (Bit)<\/p>\n<\/td>\n<td>\n<p>M<\/p>\n<\/td>\n<td>\n<p>M10512<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Axis Relay (Bit)<\/p>\n<\/td>\n<td>\n<p>M<\/p>\n<\/td>\n<td>\n<p>M10600<\/p>\n<\/td>\n<td>\n<p>40<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Flow Block is done (Bit)<\/p>\n<\/td>\n<td>\n<p>M<\/p>\n<\/td>\n<td>\n<p>M12000<\/p>\n<\/td>\n<td>\n<p>4096<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Flow Block is in progress  (Bit)<\/p>\n<\/td>\n<td>\n<p>M<\/p>\n<\/td>\n<td>\n<p>M16160<\/p>\n<\/td>\n<td>\n<p>4096<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>2-1 Motion Flow_ Special Register<\/h3>\n<p>\u203bDescribed below are the current axis number of N.<\/p>\n<p>\u203bPlease refer to Chapter 17 \u2013 <a href=\"#_Motion_Alarm_List\">Motion Flow Alarm<\/a> for the description of error codes of each register and relay.<\/p>\n<p>R Register<\/p>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Register No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p><a href=\"#R36880\">R36880<\/a><\/p>\n<\/td>\n<td>\n<p>Motion controller state<\/p>\n<\/td>\n<td>\n<p>UNIT_STATE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36881\">R36881<\/a><\/p>\n<\/td>\n<td>\n<p>Motion controller error code<\/p>\n<\/td>\n<td>\n<p>UNIT_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36882\">R36882<\/a><\/p>\n<\/td>\n<td>\n<p>Unit Program State<\/p>\n<\/td>\n<td>\n<p>UNIT_PROGRAM_STATE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36883\">R36883<\/a><\/p>\n<\/td>\n<td>\n<p>Unit Error Code<\/p>\n<\/td>\n<td>\n<p>UNIT_ERR_CODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36884\">R36884 &#8211; 36903<\/a><\/p>\n<\/td>\n<td>\n<p>Current Step<\/p>\n<\/td>\n<td>\n<p>CURRENT_STEP_1 &#8211; CURRENT_STEP_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36904\">R36904 &#8211; 36923<\/a><\/p>\n<\/td>\n<td>\n<p>Current Block State<\/p>\n<\/td>\n<td>\n<p>CURRENT_BLOCK_STATE_1 &#8211; CURRENT_BLOCK_STATE_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36924\">R36924 &#8211; 36943<\/a><\/p>\n<\/td>\n<td>\n<p>Flow State ID<\/p>\n<\/td>\n<td>\n<p>FLOW_STATE_ID_1 &#8211; FLOW_STATE_ID_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR36964\">DR36964 &#8211; 36970<\/a><\/p>\n<\/td>\n<td>\n<p>Encoder value<\/p>\n<\/td>\n<td>\n<p>ENCODER_VALUE_2 &#8211; ENCODER_VALUE_4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR36972\">DR36972<\/a><\/p>\n<\/td>\n<td>\n<p>Gray code encoder value <\/p>\n<\/td>\n<td>\n<p>GRAY_CODE_ENCODER_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR36974\">DR36974<\/a><\/p>\n<\/td>\n<td>\n<p>Gray code encoder turns <\/p>\n<\/td>\n<td>\n<p>GRAY_CODE_ENCODER_TURNS<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>R36880 Motion Controller Status\uff1a<\/p>\n<ul>\n<li>Status of Motion Control Card, the normal will be 0.<\/li>\n<li>Display a number when function 187 fails to activate Motion.<\/li>\n<li>Display a number when there is an EtherCAT communication abnormality during the motion process.<\/li>\n<li>Display a number when a significant abnormality occurs during the motion process.<\/li>\n<\/ul>\n<p>R36881 Motion Controller Error Code\uff1a<\/p>\n<ul>\n<li>Error codes of Motion Control Card, the normal will be 0.<\/li>\n<li>Display the error codes when Motion controller status is not 0.<\/li>\n<\/ul>\n<p>R36882 Motion Program Status\uff1a<\/p>\n<ul>\n<li>Displaying status after enabling Motion function.<\/li>\n<li>The value is the maximum value within the motion flow states (R36924 &#8211; 36943).<\/li>\n<li>0 : Motion is not started.<\/li>\n<\/ul>\n<p>4\uff1aMotion activated, EtherCAT connection in progress.<\/p>\n<p>6\uff1aMotion flow control in progress.<\/p>\n<p>9\uff1aMotion flow in error<\/p>\n<p>R36883 Motoin Program Error Code\uff1a<\/p>\n<ul>\n<li>The value is the error code of the last occurrence within the motion flow states (R36924 &#8211; 36933)<\/li>\n<\/ul>\n<p>R36884 \u2013 36903 Motion Branch Flow Block Number\uff1a<\/p>\n<ul>\n<li>Current floe block number of Motion branch.<\/li>\n<li>When a new motion flow is initiated or the motion flow enters a parallel branch, the foremost idle branch will be utilized.<\/li>\n<\/ul>\n<p>R36904 \u2013 36923 Motion Branch Flow Block Status\uff1a<\/p>\n<ul>\n<li>Current flow block status of Motion branch.<\/li>\n<li>0\uff1aIdle branch<\/li>\n<\/ul>\n<p>1\uff1aFlow block in control<\/p>\n<p>2\uff1aFlow block completed<\/p>\n<p>R36924 \u2013 36943 Motoin Flow Status\uff1a<\/p>\n<ul>\n<li>Status codes of Motion flow.<\/li>\n<li>After Function 187 initiates the Motion, set it to 4<\/li>\n<li>0 : Motion is not started<\/li>\n<\/ul>\n<p>4\uff1aMotion activated, EtherCAT connection in progress.<\/p>\n<p>6\uff1aMotion flow control in progress.<\/p>\n<p>9\uff1aMotion flow in error<\/p>\n<p>DR36964 \u2013 36970 External Encoder Value\uff1a<\/p>\n<ul>\n<li>HSC 4 &#8211; HSC 7 Pulse Counts.<\/li>\n<li>Need to enable HSC 4 &#8211; HSC 7 in the I\/O configuration settings<\/li>\n<\/ul>\n<p>DR36972 Gray Code Encoder Value\uff1a<\/p>\n<ul>\n<li>Value of gray code encoder.<\/li>\n<li>There are 8 bits for X8 &#8211; X15, with a range of 0 to 255.<\/li>\n<\/ul>\n<p>DR36974 Gray Code Encoder Turns\uff1a<\/p>\n<ul>\n<li>Turns of gray code encoder , with positive and negative signs.<\/li>\n<\/ul>\n<h3>2-2 Motion Control Special Relay<\/h3>\n<p>When setting the bit for motion control special register, each axis will be added with 40 bits. For example, if the HOME sensor of Axis-1 is M10605, then the HOME sensor of Axis-2 will become M10645, and so on. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Relay No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>M10520<\/p>\n<\/td>\n<td>\n<p>All axes: Servo ON<\/p>\n<\/td>\n<td>\n<p>ALL_SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10521\">M10521<\/a><\/p>\n<\/td>\n<td>\n<p>All axes: Servo Reset<\/p>\n<\/td>\n<td>\n<p>ALL_SERVO_FAULT_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10522\">M10522<\/a><\/p>\n<\/td>\n<td>\n<p>Write all mapping parameters during initialization.<\/p>\n<\/td>\n<td>\n<p>MAPPING_ALL_PARM_AFTER_INIT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10523\">M10523<\/a><\/p>\n<\/td>\n<td>\n<p>Motion control card restart.<\/p>\n<\/td>\n<td>\n<p>RESTART_MOTION_CARD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10524\">M10524<\/a><\/p>\n<\/td>\n<td>\n<p>Custom PDO packet for special registers<\/p>\n<\/td>\n<td>\n<p>ENABLE_CUSTOM_PDO<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10600\">M10600 + 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis control command: Servo ON<\/p>\n<\/td>\n<td>\n<p>SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10601\">M10601+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis control command: Fault Reset<\/p>\n<\/td>\n<td>\n<p>FAULT_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10602\">M10602+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis control command: Deceleration Stop<\/p>\n<\/td>\n<td>\n<p>DEC_STOP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10603\">M10603+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis control command: Emergency stop<\/p>\n<\/td>\n<td>\n<p>EMG_STOP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10604\">M10604+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch ON<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10605+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Origin On<\/p>\n<\/td>\n<td>\n<p>ORIG_SIG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10606+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(+) on<\/p>\n<\/td>\n<td>\n<p>LIM_POS_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10607+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(-) on<\/p>\n<\/td>\n<td>\n<p>LIM_NEG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10608+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Z Count Signal<\/p>\n<\/td>\n<td>\n<p>Z_SIG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10609+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch ON Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_ON_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10610+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch OFF Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_OFF_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10611\">M10611+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch ON<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10612\">M10612+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch ON Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_ON_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10613\">M10613+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch OFF Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_OFF_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10614+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10615\">M10615+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Positive JOG<\/p>\n<\/td>\n<td>\n<p>JOG_POS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10616\">M10616+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Negative JOG<\/p>\n<\/td>\n<td>\n<p>JOG_NEG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10617\">M10617+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 Function ON<\/p>\n<\/td>\n<td>\n<p>PROBE1_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10618\">M10618+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 Function Reset<\/p>\n<\/td>\n<td>\n<p>PROBE1_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10619\">M10619+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 Function ON<\/p>\n<\/td>\n<td>\n<p>PROBE2_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10620\">M10620+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 Function Reset<\/p>\n<\/td>\n<td>\n<p>PROBE2_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10621\">M10621+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Parameter Immediate Effect Request<\/p>\n<\/td>\n<td>\n<p>SYNC_PARM_UP_IMMED<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10622+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Parameter Next Period Effect Request<\/p>\n<\/td>\n<td>\n<p>SYNC_PARM_UP_NEXT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10623+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Clutch Edge Trigger Buffer On<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_BUF_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10624\">M10624+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Initialization of the Cam phase when the axis synchronous clutch is OFF<\/p>\n<\/td>\n<td>\n<p>ECAM_PHASE_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10625\">M10625+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Rotation Angle Choose Near<\/p>\n<\/td>\n<td>\n<p>ROT_ANG_NEAR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10626\">M10626+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Rotation Angle Target Direction<\/p>\n<\/td>\n<td>\n<p>ROT_ANG_DIR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10627\">M10627+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Mode ON<\/p>\n<\/td>\n<td>\n<p>SYNC_MODE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10628+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Pause Current Action<\/p>\n<\/td>\n<td>\n<p>PAUSE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10629\">M10629+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>High speed homing mode ON<\/p>\n<\/td>\n<td>\n<p>HOM_SKIP_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10630+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis specifies current coordinates<\/p>\n<\/td>\n<td>\n<p>SET_CUR_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10631\">M10631+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis operation mode ON<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10632\">M10632+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis operation mode unit<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_UNIT_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10633\">M10633+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis operation mode absolute coordinates<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_COOR_ABS_OR_REF_MASK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10634\">M10634+40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Main clutch phase in\/out display<\/p>\n<\/td>\n<td>\n<p>MAIN_CLUTCH_PHASE_INOUT_DISPLAY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M10635\">M10635+40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis skips the current control<\/p>\n<\/td>\n<td>\n<p>MOV_CTRL_SKIP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11240\">M11240 + 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Servo On<\/p>\n<\/td>\n<td>\n<p>IS_SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11241\">M11241+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Operation Ready<\/p>\n<\/td>\n<td>\n<p>IS_OP_READY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11242\">M11242+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis error in progress<\/p>\n<\/td>\n<td>\n<p>IS_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11243\">M11243+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis warning in progress<\/p>\n<\/td>\n<td>\n<p>IS_WARN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11244\">M11244+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Control in progress<\/p>\n<\/td>\n<td>\n<p>IS_CTRL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11245\">M11245+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Homing in progress<\/p>\n<\/td>\n<td>\n<p>IS_HOM_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11246\">M11246+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Homing done<\/p>\n<\/td>\n<td>\n<p>IS_HOM_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11247\">M11247+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Positioning in progress<\/p>\n<\/td>\n<td>\n<p>IS_MOV_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11248\">M11248+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Positioning done<\/p>\n<\/td>\n<td>\n<p>IS_MOV_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11249\">M11249+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>JOG in progress<\/p>\n<\/td>\n<td>\n<p>IS_JOG_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11250\">M11250+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>JOG done<\/p>\n<\/td>\n<td>\n<p>IS_JOG_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11251\">M11251+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Synchronizing in progress<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11252\">M11252+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Synchronizing done<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11253\">M11253+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Speed mode in progress<\/p>\n<\/td>\n<td>\n<p>IS_VEL_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11254\">M11254+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Speed mode done<\/p>\n<\/td>\n<td>\n<p>IS_VEL_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11255\">M11255+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Torque mode in progress<\/p>\n<\/td>\n<td>\n<p>IS_TORQ_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11256\">M11256+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Torque mode done<\/p>\n<\/td>\n<td>\n<p>IS_TORQ_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11257\">M11257+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis soft limit(+) status<\/p>\n<\/td>\n<td>\n<p>IS_SOFT_LIM_POS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11258\">M11258+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis soft limit(-) status<\/p>\n<\/td>\n<td>\n<p>IS_SOFT_LIM_NEG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11259\">M11259+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis origin limit status<\/p>\n<\/td>\n<td>\n<p>IS_ORIG_SIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11260\">M11260+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis limit(+) status<\/p>\n<\/td>\n<td>\n<p>IS_LIM_POS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11261\">M11261+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis limit(-) status<\/p>\n<\/td>\n<td>\n<p>IS_LIM_NEG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11262\">M11262+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 triggered<\/p>\n<p>state<\/p>\n<\/td>\n<td>\n<p>IS_PROBE1_TRIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11263\">M11263+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 triggered<\/p>\n<p>state<\/p>\n<\/td>\n<td>\n<p>IS_PROBE2_TRIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11264\">M11264+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis synchronization parameter effective state<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_PARM_UPDN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11265\">M11265+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis tracking error state<\/p>\n<\/td>\n<td>\n<p>IS_FOLLOW_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11266\">M11266+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Pause Status<\/p>\n<\/td>\n<td>\n<p>IS_PAUSE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11267\">M11267+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Homing mode Z-phase signal<\/p>\n<\/td>\n<td>\n<p>IS_Z_SIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11268\">M11268+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis operation mode action<\/p>\n<\/td>\n<td>\n<p>IS_ADV_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#M11269\">M11269+ 40*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis operation mode done<\/p>\n<\/td>\n<td>\n<p>IS_ADV_DN<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Motion control special temporary register R + 150 per axis. For example, axis 1 position control state R36980, axis 2 position control state R37130, and so on.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Relay No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p><a href=\"#R36980\">R36980 + 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis properties (Real axis or virtual axis)<\/p>\n<\/td>\n<td>\n<p>TYPE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R36984\">R36984+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Current Control Mode<\/p>\n<\/td>\n<td>\n<p>CTRL_MODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37004\">R37004+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Error Detail Information 1<\/p>\n<\/td>\n<td>\n<p>ERR_INFO_1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37005\">R37005+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Error Detail Information 2<\/p>\n<\/td>\n<td>\n<p>ERR_INFO_2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37006\">R37006+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Warning Detail Information 1<\/p>\n<\/td>\n<td>\n<p>WARN_INFO_1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37007\">R37007+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Warning Detail Information 2<\/p>\n<\/td>\n<td>\n<p>WARN_INFO_2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37012\">R37012+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Control<\/p>\n<\/td>\n<td>\n<p>CTRL_STATUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37013\">R37013+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Warning Code<\/p>\n<\/td>\n<td>\n<p>WARN_STATUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37014\">DR37014+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Command Coordinate <\/p>\n<\/td>\n<td>\n<p>CMD_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37016\">DR37016+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Command Speed<\/p>\n<\/td>\n<td>\n<p>CMD_VEL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37018\">DR37018+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Command Position<\/p>\n<\/td>\n<td>\n<p>CMD_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37020\">R37020+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Positioning Current Point No.<\/p>\n<\/td>\n<td>\n<p>CUR_PT_OR_ECAM_NUM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37021\">DR37021+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Current Coordinate<\/p>\n<\/td>\n<td>\n<p>CUR_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37023\">DR37023+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Feedback Speed Monitor<\/p>\n<\/td>\n<td>\n<p>CUR_VEL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37025\">DR37025+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Position Deviation Monitor <\/p>\n<\/td>\n<td>\n<p>CUR_COOR_DEV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37027\">DR37027+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Digital Input from Driver<\/p>\n<\/td>\n<td>\n<p>SERVO_DI_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37029\">R37029+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Current Flow ID<\/p>\n<\/td>\n<td>\n<p>CUR_FLOW_NUM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37030\">DR37030+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Contact Output <\/p>\n<\/td>\n<td>\n<p>SYNC_CONT_OUT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37032\">R37032+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Current Torque<\/p>\n<\/td>\n<td>\n<p>CUR_TORQ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37033\">DR37033+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>E-Cam Input Phase<\/p>\n<\/td>\n<td>\n<p>ECAM_IN_PHASE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37035\">DR37035+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Origin Position <\/p>\n<\/td>\n<td>\n<p>ORG_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#R37037\">R37037 &#8211; R37039+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis Status Word 1-3<\/p>\n<\/td>\n<td>\n<p>CONTROL_STATUS_WORD1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37040\">DR37040+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Main Clutch Output Phase <\/p>\n<\/td>\n<td>\n<p>MAIN_CLU_INOUT_PHASE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37042\">DR37042+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Probe 1 Coordinate<\/p>\n<\/td>\n<td>\n<p>PROBE1_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37044\">DR37044+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Probe 2 Coordinate<\/p>\n<\/td>\n<td>\n<p>PROBE2_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37050\">DR37050+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis specifies coordinates<\/p>\n<\/td>\n<td>\n<p>SET_COOR_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37052\">DR37052+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced control mode<\/p>\n<\/td>\n<td>\n<p>SET_ADV_MODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37054\">DR37054+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 1<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37056\">DR37056+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 2<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37058\">DR37058+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 3<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37060\">DR37060+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 4<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37062\">DR37062+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 5<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37064\">DR37064+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 6<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><a href=\"#DR37066\">DR37066+ 150*(n-1)<\/a><\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 7<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD7<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>M10520 All axes servo on\uff1a<\/p>\n<ul>\n<li>Rising: All axis servo on<\/li>\n<li>Falling: All axis servo off<\/li>\n<li>Axis enabled (M10600+40*(n-1)) will also change accordingly.<\/li>\n<\/ul>\n<p>M10521 All axis servo reset\uff1a<\/p>\n<ul>\n<li>Rising: All axis clearing error <\/li>\n<li>1.The motion program status (R36882) should change from 9 to 4 or 6, and (R36924 &#8211; R36933) should change from 9 to 4<\/li>\n<\/ul>\n<p>2. The motion program error code (R36883) should change to 0.<\/p>\n<p>3. If there is an error in the drive, it should be cleared at the same time.<\/p>\n<p>4. Axis Error Info (R37004 + 150*(n-1)) and (R37005 + 150*(n-1)) should change to 0.<\/p>\n<p>5. Axis Alarm Info (R37006 + 150*(n-1)) and (R37007 + 150*(n-1)) should change to 0.<\/p>\n<p>6. Axis Status is in error (M11242 + 40*(n-1)) and Error Status is in alarm (M11243 + 40*(n-1)) should be reset.<\/p>\n<p>M10522 Write all mapping parameters during initialization.\uff1a<\/p>\n<ul>\n<li>On: Complete write during initialization.<\/li>\n<li>Off: Write according to the mapping table settings.<\/li>\n<li>Enable\uff1aSynchronously write all items from the mapping table after Fun187 is executed and completed.<\/li>\n<li>Not enable\uff1aWrite the items according to the mapping table settings after Fun187 is executed and completed.<\/li>\n<\/ul>\n<p>M10523 Motion control card restart.\uff1a<\/p>\n<ul>\n<li>Rising: Restart the motion control card.<\/li>\n<li>Enable\uff1aCease all current motion control and restore to the status at PLC restart. <\/li>\n<li>When encountering a system emergency stop, it can be used to restart the motion control card.<\/li>\n<\/ul>\n<p>M10524 Custom PDO packet for special registers\uff1a<\/p>\n<ul>\n<li>Enable: Use special registers<\/li>\n<li>When enabled, use R37050~R37081 + 150*(n-1) as the EtherCAT PDO packet.<\/li>\n<\/ul>\n<p>M10600 + 40*(n-1) Axis control command Servo ON\uff1a<\/p>\n<ul>\n<li>Rising: Single axis servo on<\/li>\n<li>Falling: Single axis servo off<\/li>\n<li>Will change accordingly when all axes servo on (M10520) changes.<\/li>\n<\/ul>\n<p>M10601 + 40*(n-1) Axis control command Fault Reset\uff1a<\/p>\n<ul>\n<li>Rising: Single axis clearing error<\/li>\n<li>Motoin flow status (R36924 &#8211; R36933) of current axis motion flow No. (R37029) should change from 9 to 4.<\/li>\n<\/ul>\n<p>2. If there is an error in the drive, it should be cleared at the same time.<\/p>\n<p>3. Axis Error Info (R37004 + 150*(n-1)) and (R37005 + 150*(n-1)) should change to 0.<\/p>\n<p>4. Axis Alarm Info (R37006 + 150*(n-1)) and (R37007 + 150*(n-1)) should change to 0.<\/p>\n<p>5. Axis Status is in error (M11242 + 40*(n-1)) and Error Status is in alarm (M11243 + 40*(n-1)) should be reset.<\/p>\n<p>M10602 + 40*(n-1) Axis deceleration stop\uff1a<\/p>\n<ul>\n<li>Rising: Single axis deceleration stop.<\/li>\n<li>Using the stop mode from the axis table to stop axis and deceleration uses the deceleration setting value from the axis table.<\/li>\n<li>Trigger axis stop warning.<\/li>\n<\/ul>\n<p>M10603 + 40*(n-1) Axis emergency stop\uff1a<\/p>\n<ul>\n<li>Rising: Single axis emergency stop\t<\/li>\n<li>Trigger axis stop warning<\/li>\n<\/ul>\n<p>M10604 + 40*(n-1) Axis Synchronous main clutch ON\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by clutch ON condition in sync parameters.<\/li>\n<\/ul>\n<p>M10605 + 40*(n-1) Axis origin on\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by homing IO source in motion axis parameters.<\/li>\n<li>The axis origin limit status (M11259 + 40*(n-1)) should change accordingly.<\/li>\n<\/ul>\n<p>M10606 + 40*(n-1) Axis limit(+) on\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by homing IO source in motion axis parameters.<\/li>\n<li>The axis limit(+) status (M11260 + 40*(n-1)) should change accordingly.<\/li>\n<\/ul>\n<p>M10607 + 40*(n-1) Axis limit(-) on\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by homing IO source in motion axis parameters.<\/li>\n<li>The axis limit(-) status (M11261 + 40*(n-1)) should change accordingly<\/li>\n<\/ul>\n<p>M10608 + 40*(n-1) Z Count Signal\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by homing IO source in motion axis parameters.<\/li>\n<\/ul>\n<p>M10609 + 40*(n-1) Axis Synchronous main clutch ON Disable\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aDoes not act when axis sync main clutch  ON condition is met.<\/li>\n<\/ul>\n<p>M10610 + 40*(n-1) Axis Synchronous main clutch OFF Disable\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aDoes not act when axis sync main clutch  OFF condition is met.<\/li>\n<\/ul>\n<p>M10611 + 40*(n-1) Axis Synchronous auxiliary clutch ON\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aSet by auxiliary clutch on condition in sync parameter. <\/li>\n<\/ul>\n<p>M10612 + 40*(n-1) Axis Synchronous auxiliary clutch ON Disable\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aDoes not act when axis sync aux clutch ON condition is met. <\/li>\n<\/ul>\n<p>M10613 + 40*(n-1) Axis Synchronous auxiliary clutch OFF Disable\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aDoes not act when axis sync aux clutch OFF condition is met<\/li>\n<\/ul>\n<p>M10615 + 40*(n-1) Axis Positive JOG\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Rising edge triggers positive direction jogging. If in negative direction jogging mode, it will switch to positive direction jogging<\/li>\n<li>The speed follows the axis table JOG speed<\/li>\n<\/ul>\n<p>M10616 + 40*(n-1) Axis Negative JOG\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Rising edge triggers negative direction jogging. If in positive direction jogging mode, it will switch to negative direction jogging<\/li>\n<li>The speed follows the axis table JOG speed<\/li>\n<\/ul>\n<p>M10617 + 40*(n-1) Axis Probe 1 on\uff1a<\/p>\n<ul>\n<li>Enable\uff1aEnable the drive probe 1 function.<\/li>\n<li>When the probe is triggered, set the trigger status of axis probe 1 (M11262 + 40*(n-1)) to ON, and the axis driver probe 1 coordinates (DR37042 + 150*(n-1)) value will be updated.<\/li>\n<\/ul>\n<p>M10618 + 40*(n-1) Axis Probe 1 Function Reset\uff1a<\/p>\n<ul>\n<li>Rising Trigger<\/li>\n<li>When triggered on the rising edge, the trigger status of axis probe 1 (M11262 + 40*(n-1)) will be reset to OFF.<\/li>\n<\/ul>\n<p>M10619 + 40*(n-1) Axis Probe 2 on\uff1a<\/p>\n<ul>\n<li>Enable\uff1aEnable the drive probe 2 function.<\/li>\n<li>When the probe is triggered, set the trigger status of axis probe 2 (M11263 + 40*(n-1)) to ON, and the axis driver probe 2 coordinates (DR37044 + 150*(n-1)) value will be updated.<\/li>\n<\/ul>\n<p>M10620 + 40*(n-1) Axis Probe 2 Function Reset\uff1a<\/p>\n<ul>\n<li>Rising Trigger<\/li>\n<li>When triggered on the rising edge, the trigger status of axis probe 2 (M11263 + 40*(n-1)) will be reset to OFF.<\/li>\n<\/ul>\n<p>M10621 + 40*(n-1) Axis Synchronization Parameter Immediate Effect Request\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aImmediately update the sync parameters to the axis in synchronous control.<\/li>\n<\/ul>\n<p>M10622 + 40*(n-1) Axis Synchronization Parameter Next Period Effect Request\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aAt the beginning of the next cam cycle, update the sync parameters to the axis in sync control.<\/li>\n<\/ul>\n<p>M10623 + 40*(n-1) Axis Synchronization Clutch Edge Trigger Buffer On\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aWhen the clutch ON is set as edge-triggered, the caching function takes effect.<\/li>\n<\/ul>\n<p>M10624 + 40*(n-1) Initialization of the Cam phase when the axis synchronous clutch is OFF\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Enable\uff1aWhen the clutch is OFF, set the phase between the master clutch output end and the cam to the default value.<\/li>\n<\/ul>\n<p>M10625 + 40*(n-1) Axis rotation angle choose near\uff1a<\/p>\n<ul>\n<li>High: Off<\/li>\n<li>Low: On<\/li>\n<li>When the command is in absolute coordinates, it is determined based on axis rotation angle choose near  (M10625 + 40*(n-1)) and axis rotation angle target direction (M10626 + 40*(n-1)) .<\/li>\n<li>(High) Off\uff1aApproach the target angle in axis rotation angle target direction (M10626 + 40*(n-1)) .<\/li>\n<li>(Low) On\uff1aWhen the unit is set to display in 360 degrees, choose the nearest direction for the target position. <\/li>\n<\/ul>\n<p>M10626 + 40*(n-1) Axis rotation angle target direction\uff1a<\/p>\n<ul>\n<li>High: +<\/li>\n<li>Low: &#8211;<\/li>\n<li>Positive direction: Always approach the target angle in the positive direction.<\/li>\n<li>Negative direction: Always approach the target angle in the negative direction.<\/li>\n<\/ul>\n<p>M10627 + 40*(n-1) Axis Synchronization Mode ON\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>On\uff1aSetting the axis to sync control, if the axis is not in free control, it will trigger an axis occupancy alarm.<\/li>\n<li>Off\uff1aAxis exits sync mode, but if there is deceleration stop in sync parameters, it must wait for the deceleration completion before setting the axis to free control. <\/li>\n<\/ul>\n<p>M10628 + 40*(n-1) Axis pauses current action\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>On\uff1aPause the current action, and the action issued after the pause will be executed once the pause is released.<\/li>\n<li>Off\uff1aContinue with the current action.<\/li>\n<\/ul>\n<p>M10629 + 40*(n-1) High speed homing mode ON\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>On\uff1aNo longer need to approach the home position at creeping velocity in homing mode.<\/li>\n<\/ul>\n<p>M10630 + 40*(n-1) Axis specifies current coordinates\uff1a<\/p>\n<ul>\n<li>Rising Trigger<\/li>\n<li>When the rising edge is triggered, the value of the special register DR37050 will be set to the current coordinate.<\/li>\n<li>Only be used in axis uncontrolled or synchronous mode.<\/li>\n<li>Must be used when M10524 custom PDO packet is not enabled.<\/li>\n<\/ul>\n<p>M10631 + 40*(n-1) Axis advanced mode ON\uff1a<\/p>\n<ul>\n<li>High: On<\/li>\n<li>Low: Off<\/li>\n<li>Must be used when M10524 custom PDO packet is not enabled.<\/li>\n<li>Only be used under the synchronous mode.<\/li>\n<li>The value of special register DR37052 is regarded as the control mode: 0 for no control, 1 for position control, 2 for speed control, and 3 for torque control.<\/li>\n<li>When switching control modes, it is necessary to toggle M10631 again or set DR37052 to 0 (no control) state<\/li>\n<li>The value of special register DR37054 is considered as the control command.<\/li>\n<li>When the mode is speed mode or torque mode, the value of special register DR37056 is considered as the torque limit or speed limit.<\/li>\n<li>The default units are as follows: <\/li>\n<\/ul>\n<p>Position mode\uff1aaxis coordinate units<\/p>\n<p>Speed mode\uff1aaxis coordinate units per second<\/p>\n<p>Torque mode\uff1a0.1%.<\/p>\n<ul>\n<li>Can pre-enable M10632 to specify the units as follows:<\/li>\n<\/ul>\n<p>Position mode\uff1aPLS (Pulse)<\/p>\n<p>Speed mode\uff1aPLS\/s (Pulse per second)<\/p>\n<p>Torque mode\uff1a0.1%.<\/p>\n<p>M10632 + 40*(n-1) Axis advanced mode unit\uff1a<\/p>\n<ul>\n<li>High: Pulse Unit<\/li>\n<li>Low: Axis Table Unit<\/li>\n<li>Pulse Unit\uff1a<\/li>\n<\/ul>\n<p>Position mode\uff1aaxis coordinate units<\/p>\n<p>Speed mode\uff1aaxis coordinate units per second<\/p>\n<p>Torque mode\uff1a0.1%.<\/p>\n<ul>\n<li>Axis Table Unit\uff1aThe decimal point position refers to the number of decimal places set on the motion axis table.<\/li>\n<\/ul>\n<p>M10633 + 40*(n-1) Axis advanced mode absolute coordinates\uff1a<\/p>\n<ul>\n<li>High: absolute coordinate <\/li>\n<li>Low: relative coordinate<\/li>\n<li>Absolute coordinates: Start at the origin position.<\/li>\n<li>Relative coordinates: Start at the position triggered by M10631.<\/li>\n<li>When M10631 is set to high, the modification is ineffective.<\/li>\n<\/ul>\n<p>M10634 + 40*(n-1) \tMain clutch phase inout display\uff1a<\/p>\n<ul>\n<li>High bit: Input phase<\/li>\n<li>Low bit: Output phase<\/li>\n<li>Select whether the clutch phase displayed by DR37040 is the input phase or the output phase.<\/li>\n<\/ul>\n<p>M10635 + 40*(n-1) \tAxis skips the current control\uff1a<\/p>\n<ul>\n<li>Rising Edge: Skip the current control.<\/li>\n<li>When triggered on the rising edge, the current control is terminated, and the motion flow proceeds to the next process block.<\/li>\n<\/ul>\n<p>M11240 + 40*(n-1) Axis servo on\uff1a<\/p>\n<ul>\n<li>High: Servo on<\/li>\n<li>Low: Servo off<\/li>\n<li>Should change after M10520 or M10600+40*(n-1) trigger.<\/li>\n<\/ul>\n<p>M11241 + 40*(n-1) Operation Ready\uff1a<\/p>\n<ul>\n<li>High: Done preparing<\/li>\n<li>Low: Still preparing<\/li>\n<li>Should change after function 187 activate Motion .<\/li>\n<li>When unchanged, status codes should be visible in R36880 and R36881. <\/li>\n<\/ul>\n<p>M11242 + 40*(n-1) Axis error in progress\uff1a<\/p>\n<ul>\n<li>High: In error<\/li>\n<li>Low: No error<\/li>\n<li>The axis should stop.<\/li>\n<li>Error info should be visible in R37004 + 150*(n-1) and R37005 + 150*(n-1) .<\/li>\n<li>Can use M10521 or M10601 + 40*(n-1) to reset.<\/li>\n<\/ul>\n<p>M11243 + 40*(n-1) Axis warning in progress\uff1a<\/p>\n<ul>\n<li>High: In alarm<\/li>\n<li>Low: No alarm<\/li>\n<li>The axis will not stop.<\/li>\n<li>Alarm info should be visible in R37006 + 150*(n-1) and R37007 + 150*(n-1) .<\/li>\n<li>Can use M10521 or M10601 + 40*(n-1) to reset.<\/li>\n<\/ul>\n<p>M11244 + 40*(n-1) Control in progress\uff1a<\/p>\n<ul>\n<li>High: In control<\/li>\n<li>Low: No control<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) has a value, set it to the high bit. <\/li>\n<li>After completion, set it to the low bit.<\/li>\n<\/ul>\n<p>M11245 + 40*(n-1) Homing in progress\uff1a<\/p>\n<ul>\n<li>High: In HOME Return mode<\/li>\n<li>Low: HOME Return mode is complete<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) displays as the homing mode, set it to the high bit.<\/li>\n<li>After completion, set it to the low bit.<\/li>\n<\/ul>\n<p>M11246 + 40*(n-1) Homing done\uff1a<\/p>\n<ul>\n<li>High: HOME Return mode is complete<\/li>\n<li>Reset\uff1aTo be reset when Axis HOME Returing (M11245 + 40*(n-1)) in the high bit.<\/li>\n<\/ul>\n<p>M11247 + 40*(n-1) Positioning in progress\uff1a<\/p>\n<ul>\n<li>High: In Positioning mode<\/li>\n<li>Low: Positioning mode is complete<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) displays as the position control mode, set it to the high bit.<\/li>\n<li>After completion, set it to the low bit.<\/li>\n<\/ul>\n<p>M11248 + 40*(n-1) Positioning done\uff1a<\/p>\n<ul>\n<li>High: Positioning mode is complete<\/li>\n<li>Reset\uff1aTo be reset when in axis positioning mode (M11247 + 40*(n-1)) in the high bit<\/li>\n<\/ul>\n<p>M11249 + 40*(n-1) JOG in progress\uff1a<\/p>\n<ul>\n<li>High: In JOG mode<\/li>\n<li>Low: JOG mode is complete<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) displays as the jogging mode, set it to the high bit.<\/li>\n<li>After completion, set it to the low bit<\/li>\n<\/ul>\n<p>M11250 + 40*(n-1) JOG done\uff1a<\/p>\n<ul>\n<li>High: JOG mode is complete<\/li>\n<li>Reset\uff1aTo be reset when axis jogging (M11247 + 40*(n-1)) in the high bit. <\/li>\n<\/ul>\n<p>M11251 + 40*(n-1) Synchronizing in progress\uff1a<\/p>\n<ul>\n<li>High: Clutch connect \/ apart act<\/li>\n<li>Low: Clutch connect \/ apart done<\/li>\n<li>When main clutch ON \/ OFF connection method is set to sliding\/following, set to the high bit during the connection process.<\/li>\n<li>After completion, set it to the low bit. <\/li>\n<\/ul>\n<p>M11252 + 40*(n-1) Sychronization done\uff1a<\/p>\n<ul>\n<li>High: Clutch connect done<\/li>\n<li>Low: Clutch apart done<\/li>\n<li>The status of the axis synchronous master clutch ON \/ OFF. <\/li>\n<\/ul>\n<p>M11253 + 40*(n-1) Speed mode in progress\uff1a<\/p>\n<ul>\n<li>High: In Speed mode<\/li>\n<li>Low: Speed mode is complete<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) displays as the speed mode, set it to the high bit.<\/li>\n<li>After completion, set it to the low bit.<\/li>\n<\/ul>\n<p>M11254 + 40*(n-1) Speed mode done\uff1a<\/p>\n<ul>\n<li>High: Target speed reaxhed \/ Upper speed limit reached<\/li>\n<li>1.Speed mode reaches the target speed.<\/li>\n<\/ul>\n<p>2.Torque mode reaches the speed limit.<\/p>\n<p>M11255 + 40*(n-1) Torque mode in progress\uff1a<\/p>\n<ul>\n<li>High: In Torque mode<\/li>\n<li>Low: Torque mode is complete<\/li>\n<li>When current axis control mode (R36984 + 150*(n-1)) displays as the torque mode, set it to the high bit.<\/li>\n<li>After completion, set it to the low bit.<\/li>\n<\/ul>\n<p>M11256 + 40*(n-1) Torque mode done\uff1a<\/p>\n<ul>\n<li>High: Target torque reached \/ Upper torque limit reached<\/li>\n<li>1.Torque mode reaches the target speed.<\/li>\n<\/ul>\n<p>2.Speed mode reaches the speed limit.<\/p>\n<p>M11257 + 40*(n-1) Axis soft limit(+) status\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display the current software limit status within Motion.<\/li>\n<\/ul>\n<p>M11258 + 40*(n-1) Axis soft limit(-) status\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display the current software limit status within Motion.<\/li>\n<\/ul>\n<p>M11259 + 40*(n-1) Axis origin limit status\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display the actual limit status received within Motion.<\/li>\n<\/ul>\n<p>M11260 + 40*(n-1) Axis limit(+) status\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display the actual limit status received within Motion.<\/li>\n<\/ul>\n<p>M11261 + 40*(n-1) Axis limit(-) status\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display the actual limit status received within Motion.<\/li>\n<\/ul>\n<p>M11262 + 40*(n-1) Axis Probe 1 triggered state\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display that servo probe 1 is triggered, and the axis drive probe 1 coordinate (DR37042 + 150*(n-1)) value will be updated. <\/li>\n<\/ul>\n<p>M11263 + 40*(n-1) Axis Probe 2 triggered state\uff1a<\/p>\n<ul>\n<li>High: Status ON<\/li>\n<li>Low: Status OFF<\/li>\n<li>Display that servo probe 2 is triggered, and the axis drive probe 2 coordinate (DR37044 + 150*(n-1)) value will be updated. <\/li>\n<\/ul>\n<p>M11264 + 40*(n-1) Axis synchronization parameter effective state\uff1a<\/p>\n<ul>\n<li>High: Valid<\/li>\n<li>Display that sync parameters have been written to the axis in sync control.<\/li>\n<li>Reset condition: When both the axis sync parameter apply immediately (M10621 + 40*(n-1)) and Axis sync parameter apply next period (M10622 + 40*(n-1)) are in the low state. <\/li>\n<\/ul>\n<p>M11265 + 40*(n-1) Axis tracking error state\uff1a<\/p>\n<ul>\n<li>High: Triggered<\/li>\n<li>1.Display whether the axis following error exceeds the axis following error window.<\/li>\n<li>2.Enable when the axis following error timeout is not zero. <\/li>\n<\/ul>\n<p>M11266 + 40*(n-1) Axis pause status\uff1a<\/p>\n<ul>\n<li>High: Paused.<\/li>\n<li>Display whether the axis is currently in pause mode.<\/li>\n<\/ul>\n<p>M11267 + 40*(n-1) Homing mode Z-phase signal\uff1a<\/p>\n<ul>\n<li>High: Z-phase signal is triggered.<\/li>\n<li>Display Motion internally actual received Z-phase signal status.<\/li>\n<\/ul>\n<p>M11268 + 40*(n-1) Axis advanced mode action\uff1a<\/p>\n<ul>\n<li>High: The advanced mode is in progress.<\/li>\n<li>Low: Advanced mode completed\/left advanced mode<\/li>\n<li>The axis advanced mode is in progress.<\/li>\n<\/ul>\n<p>M11269 + 40*(n-1) Axis advanced mode done\uff1a<\/p>\n<ul>\n<li>High: Advanced mode completed.<\/li>\n<li>Low: The advanced mode is in progress \/left advanced mode<\/li>\n<li>Advanced mode completed.<\/li>\n<\/ul>\n<p>R36980+ 150*(n-1) Axis Attribute\uff1a<\/p>\n<ul>\n<li>Display the actual axis as real or virtual axis.<\/li>\n<li>Configured through motion network links or modified by Function 235.<\/li>\n<li>0\uff1aNot used<\/li>\n<\/ul>\n<p>1\uff1aActual axis<\/p>\n<p>2\uff1aVirtual axis<\/p>\n<p>R36984+ 150*(n-1) Current Axis Control Mode\uff1a<\/p>\n<ul>\n<li>Display current control mode.<\/li>\n<li>After ending any control mode, it should return to 0.<\/li>\n<li>0\uff1aNot controled<\/li>\n<\/ul>\n<p>1\uff1aPosition control mode<\/p>\n<p>2\uff1aHoming mode<\/p>\n<p>3\uff1aJogging mode<\/p>\n<p>4\uff1aSpeed mode<\/p>\n<p>5\uff1aTorque mode<\/p>\n<p>6\uff1aSync control mode<\/p>\n<p>R37004+ 150*(n-1) Axis Error Info 1\uff1a<\/p>\n<ul>\n<li>Display axis error number.<\/li>\n<li>Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).<\/li>\n<li>Refer to the alarm list for error codes.<\/li>\n<\/ul>\n<p>R37005+ 150*(n-1) Axis Error Info 2\uff1a<\/p>\n<ul>\n<li>Display current axis error flow block number.<\/li>\n<li>Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).<\/li>\n<li>Refer to the alarm list for error codes.<\/li>\n<\/ul>\n<p>R37006+ 150*(n-1) Axis Alarm Info 1\uff1a<\/p>\n<ul>\n<li>Display axis alarm number.<\/li>\n<li>Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).<\/li>\n<li>Refer to the alarm list for error codes.<\/li>\n<\/ul>\n<p>R37007+ 150*(n-1) Axis Alarm Info 2\uff1a<\/p>\n<ul>\n<li>Display current axis alarming flow block number.<\/li>\n<li>Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).<\/li>\n<li>Refer to the alarm list for error codes.<\/li>\n<\/ul>\n<p>R37012+ 150*(n-1) Axis in control\uff1a<\/p>\n<ul>\n<li>Display axis is in control.<\/li>\n<li>Same as M11244 + 40*(n-1) .<\/li>\n<\/ul>\n<p>R37013+ 150*(n-1) Axis in alarm\uff1a<\/p>\n<ul>\n<li>Display axis is in alarm.<\/li>\n<li>0\uff1aNot in alarm.<\/li>\n<\/ul>\n<p>1\uff1aIn warning,same as M11243 + 40*(n-1) .<\/p>\n<p>2\uff1aIn error,same as M11242 + 40*(n-1) .<\/p>\n<p>DR37014+ 150*(n-1) Axis Command Coordinates\uff1a<\/p>\n<ul>\n<li>Display the coordinate command calculated by the controller for axis.<\/li>\n<li>Reciprocal coordinate transformation relationship with axis command position (DR37018 + 150*(n-1)) .<\/li>\n<li>Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.<\/li>\n<\/ul>\n<p>DR37016+ 150*(n-1) Axis Command Speed\uff1a<\/p>\n<ul>\n<li>Position, HOME, Jogging, Synchronous Mode: Change rate of command coordinate (DR37014) .<\/li>\n<li>Speed Mode: Displays the speed command of the controller for the axis.<\/li>\n<li>Torque Mode: Meaningless.<\/li>\n<li>Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.<\/li>\n<\/ul>\n<p>DR37018+ 150*(n-1) Axis Command Position\uff1a<\/p>\n<ul>\n<li>Display the controller&#8217;s (pulse) position command for this axis.<\/li>\n<li>Units are pulses.<\/li>\n<li>The drive end should receive the same value.<\/li>\n<\/ul>\n<p>R37020+ 150*(n-1) Current Axis Controlling Point No.\uff1a<\/p>\n<ul>\n<li>Display the current control point number of position mode.<\/li>\n<li>Display the current cam number of sync mode.<\/li>\n<li>Should be the motion point number (motion point table) identifier.<\/li>\n<li>In the case of continuous points, it will display the number of the previous point when traveling along a continuous path between two points.<\/li>\n<\/ul>\n<p>DR37021+ 150*(n-1) Current Axis Coordinates\uff1a<\/p>\n<ul>\n<li>Display the actual axis coordinate.<\/li>\n<li>The displayed value is obtained by performing coordinate conversion on the position (pulse) value feedback from the driver end.<\/li>\n<li>The displayed value is obtained by coordinate transformation from the feedback position (pulse) value received at the drive end.<\/li>\n<li>Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.<\/li>\n<\/ul>\n<p>DR37023+ 150*(n-1) Axis feedback speed\uff1a<\/p>\n<ul>\n<li>Display the actual axis speed.<\/li>\n<li>Feedback speed from the drive end.<\/li>\n<li>The unit of the feedback speed at the drive end should be filled in with the velocity unit and velocity gain set in the unit settings of the motion axis (axis table) parameters.<\/li>\n<\/ul>\n<p>DR37025+ 150*(n-1) Axis p.osition deviation monitor\uff1a<\/p>\n<ul>\n<li>Display axis position deviation.<\/li>\n<li>This value is equal to the axis commanded position (DR37014) minus current axis position (DR37021) .<\/li>\n<li>Reference the following error in the operational setting of the motion axis configuration (axis table) parameters.<\/li>\n<\/ul>\n<p>DR37027+ 150*(n-1) Axis Driver Digital Input\uff1a<\/p>\n<ul>\n<li>Display the digital input value of the axis driver feedback.<\/li>\n<li>The definition of each bit is determined by the driver.<\/li>\n<\/ul>\n<p>R37029+ 150*(n-1) Current Axis Motion Flow No.\uff1a<\/p>\n<ul>\n<li>Display the motion flow number of the current control axis.<\/li>\n<li>0 when there is no control or when using ladder instructions.<\/li>\n<\/ul>\n<p>DR37030+ 150*(n-1) Axis contact output\uff1a<\/p>\n<ul>\n<li>Display axis contact output status.<\/li>\n<li>The current axis control mode (R36984) needs to be in sync control.<\/li>\n<li>The axis contact output is only effective when the current axis control mode (R36984) is in sync control, and synch control requires the use of E-Cam, that is., the cam data number in the synch parameters is not 0.<\/li>\n<li>The axis electronic cam input phase (DR37033) can be compared with the axis contact output.<\/li>\n<\/ul>\n<p>R37032+ 150*(n-1) Current Axis Torque\uff1a<\/p>\n<ul>\n<li>Display the torque feedback from the axis driver.<\/li>\n<li>Units are 0.1% .<\/li>\n<\/ul>\n<p>DR37033+ 150*(n-1) Axis Electronic Cam Input Phase\uff1a<\/p>\n<ul>\n<li>Display the input phase of the axis-synchronized electronic cam.<\/li>\n<li>The axis electronic cam input phase is only effective when the current axis control mode (R36984) is in sync control.<\/li>\n<li>The range of axis electronic cam input phase is from 0 to the input axis period in sync parameters.<\/li>\n<\/ul>\n<p>DR37035+ 150*(n-1) Axis HOME Position\uff1a<\/p>\n<ul>\n<li>Display the HOME (pulse) position of the axis.<\/li>\n<li>Should be power-off hold.<\/li>\n<\/ul>\n<p>R37037 &#8211; R37039+ 150*(n-1) Axis control status words\uff1a<\/p>\n<ul>\n<li>Display axis control status words.<\/li>\n<li>The bit status from axis status enable (M11240 + 40*(n-1)) to axis pause status (M11266 + 40*(n-1)).<\/li>\n<\/ul>\n<p>DR37040+ 150*(n-1) Axis main clutch output phase\uff1a<\/p>\n<ul>\n<li>Display the output phase of the axis sync main clutch.<\/li>\n<li>The axis main clutch output phase is only effective when the current axis control mode (R36984) is in sync control.<\/li>\n<li>The range of axis main clutch output phase is from 0 to the input axis period in sync parameters.<\/li>\n<\/ul>\n<p>DR37042+ 150*(n-1) Axis Driver Probe 1 Coordinates\uff1a<\/p>\n<ul>\n<li>Display the coordinate of probe 1 from axis driver feedback.<\/li>\n<li>When axis probe 1 on (M10617 + 40*(n-1)) is triggered, trigger status of axis probe 1 (M11262 + 40*(n-1)) is set to ON.<\/li>\n<\/ul>\n<p>DR37044+ 150*(n-1) Axis Driver Probe 2 Coordinates\uff1a<\/p>\n<ul>\n<li>Display the coordinate of probe 2 from axis driver feedback.<\/li>\n<li>When axis probe 2 on (M10619 + 40*(n-1)) is triggered, trigger status of axis probe 2 (M11263 + 40*(n-1)) is set to ON.<\/li>\n<\/ul>\n<p>DR37050+ 150*(n-1) Axis specifies coordinates\uff1a<\/p>\n<ul>\n<li>The unit is the same as the motion axis table unit, and the decimal point corresponds to the number of decimal places on the motion axis table.<\/li>\n<li>When M10630 axis specifies the current coordinate, set DR37050 to the current coordinate.<\/li>\n<\/ul>\n<p>DR37052+ 150*(n-1) Axis advanced control mode\uff1a<\/p>\n<ul>\n<li>The value of special register DR37052 is regarded as the control mode: 0 for no control, 1 for position control, 2 for speed control, and 3 for torque control.<\/li>\n<li>When switching control modes, it is necessary to toggle M10631 again or set DR37052 to 0 (no control) state.<\/li>\n<\/ul>\n<p>DR37054+ 150*(n-1) Axis advanced mode instruction 1\uff1a<\/p>\n<ul>\n<li>In position and speed modes, the unit is the same as the motion axis table unit, and the decimal point corresponds to the number of decimal places on the motion axis table.<\/li>\n<li>The unit can be switched to PLS, PLS\/s using M10632.<\/li>\n<li>In torque mode, the unit is fixed at 0.1%.<\/li>\n<\/ul>\n<p>DR37056+ 150*(n-1) Axis advanced mode instruction 2\uff1a<\/p>\n<ul>\n<li>In position mode, it represents the maximum speed, with units in coordinate units per second (coordinate unit\/s), or can be switched to PLS\/s using M10632.<\/li>\n<li>In speed mode, it represents the torque limit, with units at 0.1%.<\/li>\n<li>In torque mode, it represents the speed limit, with units in RPM.<\/li>\n<\/ul>\n<p>DR37058+ 150*(n-1) Axis advanced mode instruction 3\uff1a<\/p>\n<ul>\n<li>In position mode, it represents the maximum acceleration\/deceleration, with units in coordinate units per second squared (coordinate unit\/s^2), or can be switched to PLS\/s^2 using M10632.<\/li>\n<\/ul>\n<p>DR37060+ 150*(n-1) Axis advanced mode instruction 4\uff1a<\/p>\n<ul>\n<li>In position mode, it represents maximum deceleration, with units in coordinate units\/s^2, or switched to PLS\/s^2 using M10632. When set to 0, it indicates that maximum acceleration = maximum deceleration.<\/li>\n<li>In external input positioning mode, it represents maximum deceleration, with units in coordinate units\/s^2, or switched to PLS\/s^2 using M10632.<\/li>\n<\/ul>\n<p>DR37062+ 150*(n-1) Axis advanced mode instruction 5\uff1a<\/p>\n<ul>\n<li>In external input positioning mode, it represents the input source: 0 for Gray code, 1~8 for HSC0~HSC7.<\/li>\n<li>In external input positioning mode, it represents the input source: 101~116 for axis command coordinates.<\/li>\n<\/ul>\n<p>DR37064+ 150*(n-1) Axis advanced mode instruction 6\uff1a<\/p>\n<ul>\n<li>In external input positioning mode, it represents the numerator for coordinate transformation.<\/li>\n<\/ul>\n<p>DR37066+ 150*(n-1) Axis advanced mode instruction 7\uff1a<\/p>\n<ul>\n<li>In external input positioning mode, it represents the denominator for coordinate transformation.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Motion Parameters and Status (Special Register and Rela [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50],"tags":[],"class_list":["post-3248","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m06"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3248"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3248\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3248"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3248"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}