{"id":3268,"date":"2026-11-17T18:39:57","date_gmt":"2026-11-17T10:39:57","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m07-en-02\/"},"modified":"2026-11-17T18:39:57","modified_gmt":"2026-11-17T10:39:57","slug":"mplc-m07-en-02","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m07-en-02\/","title":{"rendered":"Chapter 2. Configuration of memory, single point (Digital) and Registe"},"content":{"rendered":"<h2>Chapter 2. Configuration of memory, single point (Digital) and Register in PLC<\/h2>\n<p>\u203b\u203bBeing designed with very broad flexibility range, the M-Serial PLC allows the user to access ordinary register field (containing 34768 counts of words) by the indirect addressing method. However, it may easily lead to false data writing issues if the indirect addressing parameters are improperly used. When operated in the Read-only Register Field-ROR (containing 4096 counts of words), the M-Serial PLC does not allow the user to access the register by the indirect addressing method. If the user needs to create important parameter values, it is recommended that the ROR (Read-only Register) Field should be used in order to execute the desired reading and writing according to the respective program commands. The main purpose is to avoid the issues that may be generated due to the incorrect parameters required for the indirect addressing.<\/p>\n<h3>2-1  M PLC Memory Configuration<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-001.png\" \/>\t                                                                                                                                  <\/p>\n<p>PLC memory configuration diagram <\/p>\n<h3>2-2  Digital and Register Configuration<\/h3>\n<p>This configuration is the factory setting:<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"5\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Specifications<\/p>\n<\/td>\n<td>\n<p>Note<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>Single Point (BIT State)<\/p>\n<\/td>\n<td>\n<p>X<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Input contact (DI) (Max. point count: 2048 points)<\/p>\n<\/td>\n<td>\n<p>X0\uff5eX1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external digital input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output relay (DO) (Max. point count: 2048 points)<\/p>\n<\/td>\n<td>\n<p>Y0\uff5eY1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external digital output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>TR<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Temporary relay<\/p>\n<\/td>\n<td>\n<p>TR0\uff5eTR31(32)<\/p>\n<p>(Reserved for system operations)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>M<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Internal<br \/>relay<\/p>\n<\/td>\n<td>\n<p>M0\uff5eM9119 (9120) <\/p>\n<\/td>\n<td>\n<p>M0\uff5eM9119 can be configured as retentive or non-retentive relay.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Special Relay<\/p>\n<\/td>\n<td>\n<p>M9120\uff5eM25599 (16480)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>S<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Step Relay<\/p>\n<\/td>\n<td>\n<p>S0\uff5eS3103 (3104)<\/p>\n<\/td>\n<td>\n<p>S0\uff5eS3103 Can be configured as retentive or non-retentive relay.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>T<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Timer <\/p>\n<p>&quot;Time-Up&quot; status contact<\/p>\n<\/td>\n<td>\n<p>T0\uff5eT1023 (1024)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>C<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Counter <\/p>\n<p>&quot;Counter-Up&quot; status contact<\/p>\n<\/td>\n<td>\n<p>C0\uff5eC1279 (1280)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"14\">\n<p>Register (WORD Data)<\/p>\n<p>   Register (WORD Data)<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>TMR<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Timer current value register<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0.001S Time Base<\/p>\n<\/td>\n<td>\n<p>T0\uff5eT255 (256) *<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>T0\uff5eT1023 numbers for each time base can be adjusted.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0.01S Time Base<\/p>\n<\/td>\n<td>\n<p>T256\uff5eT511 (256) *<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>0.1S Time Base<\/p>\n<\/td>\n<td>\n<p>T512\uff5eT767 (256) *<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>1S Time Base<\/p>\n<\/td>\n<td>\n<p>T768\uff5eT1023 (256) *<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>CTR<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Counter current value register<\/p>\n<\/td>\n<td>\n<p>16-bit<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>C0\uff5eC1023 (1024)<\/p>\n<\/td>\n<td>\n<p>Can be configured as non-retentive or retentive.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32-bit<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>C1024\uff5eC1279 (256) <\/p>\n<\/td>\n<td>\n<p>Can be configured as non-retentive or retentive.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>HR<\/p>\n<p>DR<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"5\">\n<p>Data Register<\/p>\n<\/td>\n<td>\n<p>Retentive<\/p>\n<\/td>\n<td>\n<p>R0\uff5eR14999 (15000)<\/p>\n<p>* Can be configured as non-retentive<br \/>D0\uff5eD7999 (8000)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Non-Retentive<\/p>\n<\/td>\n<td>\n<p>R15000\uff5eR34767 (19768)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>HR<\/p>\n<p>ROR<\/p>\n<\/td>\n<td>\n<p>Retentive<\/p>\n<\/td>\n<td>\n<p>R43224\uff5eR47319 (4096) <\/p>\n<p>* When not configured as ROR, it can serve normal register (for read\/write)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Read Only Register (ROR)<\/p>\n<\/td>\n<td>\n<p>R43224\uff5eR47319 can be set as ROR ~ default setting is \u201c0\u201d *<\/p>\n<\/td>\n<td>\n<p>ROR is stored in special ROR area and not occupy program space<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>File Register<\/p>\n<\/td>\n<td>\n<p>F0\uff5eF65535(65536)<\/p>\n<p>* Save\/retrieved via dedicated instruction<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>IR<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Input Register (AI)<\/p>\n<\/td>\n<td>\n<p>R34768\uff5eR34895 (128)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external analog input<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OR<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output Register (AO)<\/p>\n<\/td>\n<td>\n<p>R35024\uff5eR35151 (128)<\/p>\n<\/td>\n<td>\n<p>Corresponding to external analog output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>SR<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Special System Register<\/p>\n<\/td>\n<td>\n<p>R35280\uff5eR43223 (7944)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"9\"><\/td>\n<td rowspan=\"7\">\n<p>\u3008Special  Register\u3009<\/p>\n<\/td>\n<td>\n<p>0.1ms HST Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35451~R35466(16)<\/p>\n<\/td>\n<td rowspan=\"5\"><\/td>\n<\/tr>\n<tr>\n<td>\n<p>1ms STM Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35435~R35442(8)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10ms LTM Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35443~R35450(8)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0.1ms HSTA Circulation Counter Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>DR35467<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>High-Speed Counter Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>R35280~R35311(32)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Calendar Registers<\/p>\n<\/td>\n<td>\n<p>R35312<\/p>\n<p>(Second)<\/p>\n<\/td>\n<td>\n<p>R35313 (Minute)<\/p>\n<\/td>\n<td>\n<p>R35314 (Hour)<\/p>\n<\/td>\n<td>\n<p>R35315<\/p>\n<p>(Day)<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35316<\/p>\n<p>(Month)<\/p>\n<\/td>\n<td>\n<p>R35317 (Year)<\/p>\n<\/td>\n<td>\n<p>R35318 (Week)<\/p>\n<\/td>\n<td>\n<p>R35319 (Hour\uff0bMinute)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>FR<\/p>\n<\/td>\n<td>\n<p>File Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>F0~F32767(32768)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>XR<\/p>\n<\/td>\n<td>\n<p>Index Register<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>V: R43214<\/p>\n<p>Z: R43216<\/p>\n<p>P0\uff5eP9 : <\/p>\n<p>R43194, R43196, R43198, R43200, R43202, R43204, R43206, R43208, R43210, R43212<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Digital and Register Configuration<\/p>\n<p>Note: During power up or changing operation mode from STOP\u2192RUN, all contents in non-retentive relays or registers will be cleared to 0; the retentive relays or registers will remain the same state as before.<\/p>\n<h3>2-3  CPU Special Relay Details<\/h3>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Relay No.<\/p>\n<\/td>\n<td>\n<p>Function\/TAG Symbol<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>1. Stop, Prohibit Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9120<\/p>\n<\/td>\n<td>\n<p>Emergency Stop control<\/p>\n<p>EMERGENCY_STOP_CTRL<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>If 1, PLC will be stopped.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>2. Disable, Clear Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9121<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Reserve<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9122<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Disable Status Retent Select<\/p>\n<p>DISABLE_STATUS_RETENT_CTR<\/p>\n<\/td>\n<td>\n<p>Disabled when at 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9123<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Clear Non-Retentive Relays<\/p>\n<p>CLR_NON_RETENT_RELAY<\/p>\n<\/td>\n<td>\n<p>Cleared when at 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9124<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Clear Retentive Relays<\/p>\n<p>CLR_RETENT_RELAY<\/p>\n<\/td>\n<td>\n<p>Cleared when at 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>M9125<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Clear Non-Retentive Registers<\/p>\n<p>CLR_NON_RETENT_REG<\/p>\n<\/td>\n<td>\n<p>Cleared when at 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>M9126<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Clear Retentive Registers<\/p>\n<p>CLR_RETENT_REG<\/p>\n<\/td>\n<td>\n<p>Cleared when at 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"5\">\n<p>3. Pulse Signals<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9127<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"4\">\n<ul>\n<li>\n<ol>\n<li>S Clock pulse<\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<p>CLK_PULSE_0_01S<\/p>\n<ul>\n<li>\n<ol>\n<li>S Clock pulse   <\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<p>CLK_PULSE_0_1S<\/p>\n<p>1 S Clock pulse<\/p>\n<p>CLK_PULSE_1S<\/p>\n<p>60 S Clock pulse<\/p>\n<p>CLK_PULSE_60S<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"4\">\n<p><img decoding=\"async\" alt=\"D:\\patrick\\\u8aaa\u660e\u66f8\u7ffb\u8b6f\\\u5716\\11.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-002.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9218<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9129<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9130<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9131<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"7\">\n<p>Initial Pulse (First Scan) <\/p>\n<p>CLK_PULSE_INIT<\/p>\n<p>Scan Cyclic Pulse \u2782<\/p>\n<p>CLK_PULSE_SCAN<\/p>\n<p>PLC Working Mode<\/p>\n<p>PLC_WORKING_MODE<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"7\">\n<p>=0, PLC working at STOP Mode<\/p>\n<p>=1, PLC working at RUN Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9132<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>M9133<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<p>4. Error Messages<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9134<\/p>\n<\/td>\n<td>\n<p>System Error Warning<\/p>\n<p>CPU_ABNL_WARNING<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1: Indicating no expansion unit or exceed the limit on number of I\/O points<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<p>5. Port1~Port2 Controls<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>M9135<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Port1 Work Indicator<\/p>\n<p>COM_BUSY_P1<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0: Port 1 Busy<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>1: Port 1 Ready<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9136<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Port 1 Work Indicator<\/p>\n<p>COM_DN_P1<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1: Complete all communication transactions of FUN151 (CLINK), only one scan is ON.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9137<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Port 1 Communication Status<\/p>\n<p>COM_STATUS_P1<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Port 1 has received and transmitted a message<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9138<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Port 2 Work Indicator<\/p>\n<p>COM_BUSY_P2<\/p>\n<\/td>\n<td>\n<p>0: Port 2 Busy<\/p>\n<p>1: Port 2 Ready<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9139<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Port 2 Work Indicator<\/p>\n<p>COM_DN_P2<\/p>\n<\/td>\n<td>\n<p>1: Complete all communication transactions of FUN151 (CLINK), only one scan is ON.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9140<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Port 2 Communication Status<\/p>\n<p>COM_STATUS_P2<\/p>\n<\/td>\n<td>\n<p>1: Port 2 has received and transmitted a message<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>6. HSC0\uff5eHSC7 Controls <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9141<\/p>\n<\/td>\n<td>\n<p>HSC0 Software Mask<\/p>\n<p>HSC0_MSK<\/p>\n<\/td>\n<td>\n<p>1: Mask<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9142<\/p>\n<\/td>\n<td>\n<p>HSC0 Software Clear<\/p>\n<p>HSC0_CLR<\/p>\n<\/td>\n<td>\n<p>1: Clear<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9143<\/p>\n<\/td>\n<td>\n<p>HSC1 Software Mask<\/p>\n<p>HSC1_MSK<\/p>\n<\/td>\n<td>\n<p>1: Mask<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9144<\/p>\n<\/td>\n<td>\n<p>HSC1 Software Clear<\/p>\n<p>HSC1_CLR<\/p>\n<\/td>\n<td>\n<p>1: Clear<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9145<\/p>\n<\/td>\n<td>\n<p>HSC2 Software Mask<\/p>\n<p>HSC2_MSK<\/p>\n<\/td>\n<td>\n<p>1: Mask<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9146<\/p>\n<\/td>\n<td>\n<p>HSC2 Software Clear<\/p>\n<p>HSC2_CLR<\/p>\n<\/td>\n<td>\n<p>1: Clear<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9147<\/p>\n<\/td>\n<td>\n<p>HSC3 Software Mask<\/p>\n<p>HSC3_MSK<\/p>\n<\/td>\n<td>\n<p>1: Mask<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9148<\/p>\n<\/td>\n<td>\n<p>HSC3 Software Clear<\/p>\n<p>HSC3_CLR<\/p>\n<\/td>\n<td>\n<p>1: Clear<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9149<\/p>\n<\/td>\n<td>\n<p>Port3 Work Indicator(READY)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9150<\/p>\n<\/td>\n<td>\n<p>Port3 Work Indicator(TABLE COMPLETE)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9151<\/p>\n<\/td>\n<td>\n<p>Port3 Communication Status<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9152<\/p>\n<\/td>\n<td>\n<p>Port4 Work Indicator(READY)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9153<\/p>\n<\/td>\n<td>\n<p>Port4 Work Indicator(TABLE COMPLETE)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9154<\/p>\n<\/td>\n<td>\n<p>Port4 Communication Status<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9155~<\/p>\n<p>M9159<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>7. Communication\/Timing\/Counting Controls<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9160<\/p>\n<\/td>\n<td>\n<p>CAM Function Cross 0 Degree Selection<\/p>\n<p>CAM_FUNC_SELECT<\/p>\n<\/td>\n<td>\n<p>M9160=1:<br \/> When the upper limit value of the FUN 112 (BKCMP) command is less than the lower limit value, it can be executed (for example, the upper limit value is 10\u00b0, the lower limit value is 350\u00b0, when the current angle is 350\u00b0~10\u00b0, the comparison bit is 1).<\/p>\n<p>M9160=0\uff1a<\/p>\n<p>If among the upper and lower limit setting values, the upper limit value is less than the lower limit value, the limit value error flag<\/p>\n<p>The number &quot;ERR&quot; is set to 1, and the comparison output of this group is 0.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9161<\/p>\n<\/td>\n<td>\n<p>High-Speed Pulse Output Stop Selection<\/p>\n<p>HSPSO_STOP_SELECT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9162<\/p>\n<\/td>\n<td>\n<p>Update MODBUS Planning<\/p>\n<p>MODBUS_UPDATE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9163<\/p>\n<\/td>\n<td>\n<p>Update COM Setting<\/p>\n<p>COM_UPDATE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9164<\/p>\n<\/td>\n<td>\n<p>Reboot Network Interface<\/p>\n<p>ETH_UPDATE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9165<\/p>\n<\/td>\n<td>\n<p>Enable DHCP<\/p>\n<p>ETH_DHCP_ENABLE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9166<\/p>\n<\/td>\n<td>\n<p>1ms Timer STM 0 Control<\/p>\n<p>STM0_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9167<\/p>\n<\/td>\n<td>\n<p>1ms Timer STM 1 Control<\/p>\n<p>STM1_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9168<\/p>\n<\/td>\n<td>\n<p>1ms Timer STM 2 Control<\/p>\n<p>STM2_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9169<\/p>\n<\/td>\n<td>\n<p>1ms Timer STM 3 Control<\/p>\n<p>STM3_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9170<\/p>\n<\/td>\n<td>\n<p>10ms Timer LTM 0 Control<\/p>\n<p>LTM0_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9171<\/p>\n<\/td>\n<td>\n<p>10ms Timer LTM 1 Control<\/p>\n<p>LTM1_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9172<\/p>\n<\/td>\n<td>\n<p>10ms Timer LTM 2 Control<\/p>\n<p>LTM2_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9173<\/p>\n<\/td>\n<td>\n<p>10ms Timer LTM 3 Control<\/p>\n<p>LTM3_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9174<\/p>\n<\/td>\n<td>\n<p>0.1 ms HST 0 Control<\/p>\n<p>HST0_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9175<\/p>\n<\/td>\n<td>\n<p>0.1ms HST 1 Control<\/p>\n<p>HST1_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9176<\/p>\n<\/td>\n<td>\n<p>0.1ms HST 2 Control<\/p>\n<p>HST2_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9177<\/p>\n<\/td>\n<td>\n<p>0.1ms HST 3 Control<\/p>\n<p>HST3_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9178<\/p>\n<\/td>\n<td>\n<p>0.1ms HSTA Circulation Counter Control<\/p>\n<p>HSTA_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>8. RTC Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9179<\/p>\n<\/td>\n<td>\n<p>RTC Setting<\/p>\n<p>RTC_UPDATE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9180<\/p>\n<\/td>\n<td>\n<p>30 S Adjustment<\/p>\n<p>RTC_30S_ADJUSTMENT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9181<\/p>\n<\/td>\n<td>\n<p>RTC Installation Checking<\/p>\n<p>RTC_INSTALL_CHK<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9182<\/p>\n<\/td>\n<td>\n<p>Set Value Error<\/p>\n<p>RTC_SET_VALUE_ERROR<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>9. PS0~7 Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9183<\/p>\n<\/td>\n<td>\n<p>PSO0 Indicator<\/p>\n<p>PSO0_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9184<\/p>\n<\/td>\n<td>\n<p>PSO1 Indicator<\/p>\n<p>PSO1_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9185<\/p>\n<\/td>\n<td>\n<p>PSO2 Indicator<\/p>\n<p>PSO2_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9186<\/p>\n<\/td>\n<td>\n<p>PSO3 Indicator<\/p>\n<p>PSO3_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9187<\/p>\n<\/td>\n<td>\n<p>PSO0 Done<\/p>\n<p>PSO0_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9188<\/p>\n<\/td>\n<td>\n<p>PSO1 Done<\/p>\n<p>PSO1_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9189<\/p>\n<\/td>\n<td>\n<p>PSO2 Done<\/p>\n<p>PSO2_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9190<\/p>\n<\/td>\n<td>\n<p>PSO3 Done<\/p>\n<p>PSO3_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9191<\/p>\n<\/td>\n<td>\n<p>PSO4 Indicator<\/p>\n<p>PSO4_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9192<\/p>\n<\/td>\n<td>\n<p>PSO5 Indicator<\/p>\n<p>PSO5_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9193<\/p>\n<\/td>\n<td>\n<p>PSO6 Indicator<\/p>\n<p>PSO6_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9194<\/p>\n<\/td>\n<td>\n<p>PSO7 Indicator<\/p>\n<p>PSO7_BUSY<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9195<\/p>\n<\/td>\n<td>\n<p>PSO4 Done <\/p>\n<p>PSO4_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9196<\/p>\n<\/td>\n<td>\n<p>PSO5 Done<\/p>\n<p>PSO5_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9197<\/p>\n<\/td>\n<td>\n<p>PSO6 Done<\/p>\n<p>PSO6_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9198<\/p>\n<\/td>\n<td>\n<p>PSO7 Done<\/p>\n<p>PSO7_DN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>10. Expansion Module Operation Field<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M9199~<\/p>\n<p>M10511<\/p>\n<\/td>\n<td>\n<p>Please refer to the respective Expansion Module User Manual.<\/p>\n<\/td>\n<td>\n<p>Because the number of special registers is related to the expansion module that will be set by the user, the sequence is not set with a fixed number order. Therefore, it will be learned through the following method:<\/p>\n<p>The number of Special Register can be displayed by clicking on the following profile: \u201cProject-&gt; Device View-&gt;Device Monitor<\/p>\n<p>-&gt;select desired module.\u201d<\/p>\n<p>The data indicated below are explained by using Data Buffer Relay as the example. The Data Buffer Relay will be started with the same method as the Triggering Data Buffer Relay.<\/p>\n<p><img decoding=\"async\" alt=\"D:\\patrick\\\u8aaa\u660e\u66f8\u7ffb\u8b6f\\\u5716\\3.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-003.png\" \/><\/p>\n<p><img decoding=\"async\" alt=\"D:\\patrick\\\u8aaa\u660e\u66f8\u7ffb\u8b6f\\\u5716\\4.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-004.png\" \/><\/p>\n<p><img decoding=\"async\" alt=\"D:\\patrick\\\u8aaa\u660e\u66f8\u7ffb\u8b6f\\\u5716\\\u5716\u72471.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-005.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10512~<\/p>\n<p>M16095<\/p>\n<\/td>\n<td>\n<p>For Motion related special relays<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>CPU Module special relay list<\/p>\n<p>\u203bAll special relays do not provide Up\/Down differential contact commands TU. If it is necessary to perform differential action on the special relay, it can be replaced by an indirect method. (Refer to the picture below)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-006.png\" \/><\/p>\n<p> Differential Action Connection of Special Relay<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Note: All special relays or registers attached with \u201c\u25e4\u201d symbol shown in the above table are write prohibited. At the same time, this type of relay still prohibits\/disables control and mandatory setting, and does not provide TU and TD contacts.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>2-4  CPU Special Registers Details<\/h3>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>Register No.\/<\/p>\n<p>System Tag Code<\/p>\n<\/th>\n<th>\n<p>Function\/System Tag Symbol<\/p>\n<\/th>\n<th>\n<p>Description<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35280<\/p>\n<\/th>\n<th>\n<p>HSC0 current value Low word<\/p>\n<p>HSC0_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35281<\/p>\n<\/th>\n<th>\n<p>HSC0 current value High word<\/p>\n<p>HSC0_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35282<\/p>\n<\/th>\n<th>\n<p>HSC0 preset value Low word<\/p>\n<p>HSC0_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35283<\/p>\n<\/th>\n<th>\n<p>HSC0 preset value High word<\/p>\n<p>HSC0_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35284<\/p>\n<\/th>\n<th>\n<p>HSC1 current value Low word<\/p>\n<p>HSC1_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35285<\/p>\n<\/th>\n<th>\n<p>HSC1 current value High word<\/p>\n<p>HSC1_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35286<\/p>\n<\/th>\n<th>\n<p>HSC1 preset value Low word<\/p>\n<p>HSC1_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35287<\/p>\n<\/th>\n<th>\n<p>HSC1 preset value High word<\/p>\n<p>HSC1_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35288<\/p>\n<\/th>\n<th>\n<p>HSC2 current value Low word<\/p>\n<p>HSC2_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35289<\/p>\n<\/th>\n<th>\n<p>HSC2 current value High word<\/p>\n<p>HSC2_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35290<\/p>\n<\/th>\n<th>\n<p>HSC2 preset value Low word<\/p>\n<p>HSC2_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35291<\/p>\n<\/th>\n<th>\n<p>HSC2 preset value High word<\/p>\n<p>HSC2_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35292<\/p>\n<\/th>\n<th>\n<p>HSC3 current value Low word<\/p>\n<p>HSC3_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35293<\/p>\n<\/th>\n<th>\n<p>HSC3 current value High word<\/p>\n<p>HSC3_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35294<\/p>\n<\/th>\n<th>\n<p>HSC3 preset value Low word<\/p>\n<p>HSC3_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35295<\/p>\n<\/th>\n<th>\n<p>HSC3 preset value High word<\/p>\n<p>HSC3_PV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>Register No.\/<\/p>\n<p>System Tag Code<\/p>\n<\/th>\n<th>\n<p>Function\/System Tag Symbol<\/p>\n<\/th>\n<th>\n<p>Description<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35296<\/p>\n<\/th>\n<th>\n<p>HSC4 current value Low word<\/p>\n<p>HSC4_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35297<\/p>\n<\/th>\n<th>\n<p>HSC4 current value High word<\/p>\n<p>HSC4_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35298<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35299<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35300<\/p>\n<\/th>\n<th>\n<p>HSC5 current value Low word<\/p>\n<p>HSC5_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35301<\/p>\n<\/th>\n<th>\n<p>HSC5 current value High word<\/p>\n<p>HSC5_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35302<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35303<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35304<\/p>\n<\/th>\n<th>\n<p>HSC6 current value Low word<\/p>\n<p>HSC6_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35305<\/p>\n<\/th>\n<th>\n<p>HSC6 current value High word<\/p>\n<p>HSC6_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35306<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35307<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35308<\/p>\n<\/th>\n<th>\n<p>HSC7 current value Low word<\/p>\n<p>HSC7_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35309<\/p>\n<\/th>\n<th>\n<p>HSC7 current value High word<\/p>\n<p>HSC7_CV<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35310<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35311<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35312<\/p>\n<\/th>\n<th>\n<p>Second of calendar<\/p>\n<p>RTC_SECOND<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35313<\/p>\n<\/th>\n<th>\n<p>Minute of RTC<\/p>\n<p>RTC_MINUTE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35314<\/p>\n<\/th>\n<th>\n<p>Hour of RTC<\/p>\n<p>RTC_HOUR<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35315<\/p>\n<\/th>\n<th>\n<p>Date of RTC<\/p>\n<p>RTC_DAY<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35316<\/p>\n<\/th>\n<th>\n<p>Month of RTC<\/p>\n<p>RTC_MONTH<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35317<\/p>\n<\/th>\n<th>\n<p>Year of RTC<\/p>\n<p>RTC_YEAR<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35318<\/p>\n<\/th>\n<th>\n<p>Week of RTC<\/p>\n<p>RTC_DAY_OF_WEEK<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35319<\/p>\n<\/th>\n<th>\n<p>Hour (High byte) + Minute (Low byte)<\/p>\n<p>RTC_HOUR_MINUTE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35320<\/p>\n<\/th>\n<th>\n<p>Error code of PSO0<\/p>\n<p>PSO0_ERR_CODE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35321<\/p>\n<\/th>\n<th>\n<p>Error code of PSO1<\/p>\n<p>PSO1_ERR_CODE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35322<\/p>\n<\/th>\n<th>\n<p>Error code of PSO2<\/p>\n<p>PSO2_ERR_CODE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35323<\/p>\n<\/th>\n<th>\n<p>Error code of PSO3<\/p>\n<p>PSO3_ERR_CODE<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35324<\/p>\n<\/th>\n<th>\n<p>Completed step number of positioning program for PSO0<\/p>\n<p>PSO0_DN_STEP_NUM<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35325<\/p>\n<\/th>\n<th>\n<p>Completed step number of positioning program for PSO1<\/p>\n<p>PSO1_DN_STEP_NUM<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35326<\/p>\n<\/th>\n<th>\n<p>Completed step number of positioning program for PSO2<\/p>\n<p>PSO2_DN_STEP_NUM<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>R35327<\/p>\n<\/th>\n<th>\n<p>Completed step number of positioning program for PSO3<\/p>\n<p>PSO3_DN_STEP_NUM<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35328<\/p>\n<\/th>\n<th>\n<p>Output frequency for Low Word of PSO0<\/p>\n<p>PSO0_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35329<\/p>\n<\/th>\n<th>\n<p>Output frequency for High Word of PSO0<\/p>\n<p>PSO0_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35330<\/p>\n<\/th>\n<th>\n<p>Output frequency for Low Word of PSO1<\/p>\n<p>PSO1_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35331<\/p>\n<\/th>\n<th>\n<p>Output frequency for High Word of PSO1<\/p>\n<p>PSO1_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35332<\/p>\n<\/th>\n<th>\n<p>Output frequency for Low Word of PSO2<\/p>\n<p>PSO2_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35333<\/p>\n<\/th>\n<th>\n<p>Output frequency for High Word of PSO2<\/p>\n<p>PSO2_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35334<\/p>\n<\/th>\n<th>\n<p>Output frequency for Low Word of PSO3<\/p>\n<p>PSO3_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35335<\/p>\n<\/th>\n<th>\n<p>Output frequency for High Word of PSO3<\/p>\n<p>PSO3_CUR_FREQ<\/p>\n<\/th>\n<th>\n<p>&#8211;<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35336 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for Low Word of PSO0<\/p>\n<p>PSO0_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35337 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for High Word of PSO0<\/p>\n<p>PSO0_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>R35338 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for Low Word of PSO1<\/p>\n<p>PSO1_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35339 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for High Word of PSO1<\/p>\n<p>PSO1_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35340 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for Low Word of PSO2<\/p>\n<p>PSO2_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35341 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for High Word of PSO2<\/p>\n<p>PSO2_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35342 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for Low Word of PSO3<\/p>\n<p>PSO3_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35343 <\/p>\n<\/th>\n<th>\n<p>Current pulse position for High Word of PSO3<\/p>\n<p>PSO3_CUR_POS<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35344 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for Low Word of PSO0<\/p>\n<p>PSO0_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35345 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for High Word of PSO0<\/p>\n<p>PSO0_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35346 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for Low Word of PSO1<\/p>\n<p>PSO1_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35347 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for High Word of PSO1<\/p>\n<p>PSO1_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35348 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for Low Word of PSO2<\/p>\n<p>PSO2_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>R35349 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for High Word of PSO2<\/p>\n<p>PSO2_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35350 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for Low Word of PSO3<\/p>\n<p>PSO3_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35351 <\/p>\n<\/th>\n<th>\n<p>Pulse count remaining for output for High Word of PSO3<\/p>\n<p>PSO3_REMAINING_COUNT<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35352 <\/p>\n<\/th>\n<th>\n<p>COM1 Communication Parameters Setting<\/p>\n<p>COM_PARAM_P1<\/p>\n<\/th>\n<th>\n<p>Set Baud Rate, Data bit\u2026 of Port 1<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35353<\/p>\n<\/th>\n<th>\n<p>COM2 Communication Parameters Setting<\/p>\n<p>COM_PARAM_P2 <\/p>\n<\/th>\n<th>\n<p>Set Baud Rate, Data bit\u2026 of Port 2<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35354<\/p>\n<\/th>\n<th>\n<p>COM1 &amp; COM2 connection setting<\/p>\n<p>COM_STN_CHK_P1<\/p>\n<p>COM_STN_CHK_P2<\/p>\n<\/th>\n<th>\n<ul>\n<li>Low Byte of R35354:<br \/>=1, Port 1 without station number checking for FATEK&#8217;s external communication protocol (communicating with MMI\/SCADA)<br \/>\u22601,Port 1 checks station number, it allows multi-drop network for data acquisition<\/li>\n<li>High Byte of R35354:<br \/>=1, Port 2 without station number checking for FATEK&#8217;s external<br \/>communication protocol (communicating with MMI\/SCADA)<br \/>\u22601,Port 2 checks station number, it allows multi-drop network for data acquisition.<\/li>\n<\/ul>\n<\/th>\n<\/tr>\n<\/thead>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th colspan=\"2\">\n<p>R35355<\/p>\n<\/th>\n<th>\n<p>Communication protocol setting for COM1 and COM2<\/p>\n<p>COM_PROTOCOL<\/p>\n<\/th>\n<th colspan=\"2\">\n<p>Set Port1 and Port2 as the FATEK or Modbus RTU\/ASCII communication protocol<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">\n<p>R35356<\/p>\n<\/th>\n<th>\n<p>Reply delay time settings for COM 1 and COM2<\/p>\n<\/th>\n<th colspan=\"2\"><\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">\n<p>R35357<\/p>\n<\/th>\n<th>\n<p>Transmission delay and reception error detection time setting when COM1 is used as the master station<\/p>\n<p>COM_TX_DELAY_P1<\/p>\n<\/th>\n<th colspan=\"2\"><\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">\n<p>R35358<\/p>\n<\/th>\n<th>\n<p>Transmission delay and reception error detection time setting when COM2 is used as the master station<\/p>\n<p>COM_TX_DELAY_P2<\/p>\n<\/th>\n<th colspan=\"2\"><\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">\n<p>R35359<\/p>\n<\/th>\n<th>\n<p>Reserved<\/p>\n<\/th>\n<th colspan=\"2\"><\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">\n<p>R35360<\/p>\n<\/th>\n<th>\n<p>System error indication<\/p>\n<p>(Need to confirm with LED)<\/p>\n<p>CPU_ERROR<\/p>\n<\/th>\n<th colspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>ERR1\/ERR2 LED<\/p>\n<\/td>\n<td>\n<p>SR\/MASK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Out of Memory<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Initialization Error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Systen Error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Stack Error<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Check Code Error Indication<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0004<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power-on detection is power-off for trial operation<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Check Code Error Indication<\/p>\n<\/td>\n<td>\n<p>ON\/ON<\/p>\n<\/td>\n<td>\n<p>R35362\/0x3E00<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion Module Detection Error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0001<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion Module Configuration File Error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0002<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The number of expansion modules does not match the host project<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0004<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Expansion module I\/O points out of range<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0008<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The number of expansion modules exceeds the range<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Control Unit Queue Error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0080<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Control Unit Overflow Error<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Motion Control Unit Emergency Stop<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Watchdog Reset Check<\/p>\n<\/td>\n<td>\n<p>ON\/OFF<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0010<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Invalid Memory Card Detection Indication<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0010<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Memory Card Operation Error Indication<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0020<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PLC ID does not match PROG ID<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35360\/0x0040<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The application exceeds the capabilities of this CPU<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x0800<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>System Service Error Indication<\/p>\n<\/td>\n<td>\n<p>OFF\/ON<\/p>\n<\/td>\n<td>\n<p>R35361\/0x8000<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35361<\/p>\n<p>~R35362<\/p>\n<\/th>\n<th colspan=\"3\">\n<p>CPU Status Indication<\/p>\n<p>CPU_STATUS<\/p>\n<\/th>\n<th>\n<p>BIT0: CPU RUN or Stop<\/p>\n<p>BIT1: Resvered<\/p>\n<p>BIT2: System Check Code Error<\/p>\n<p>BIT3: Memory Card Ready display<\/p>\n<p>BIT4: Watch-Dog Error<\/p>\n<p>BIT5: Motion Control Unit Detection<\/p>\n<p>BIT6: PLC ID Protection<\/p>\n<p>BIT7: Emergency Stop<\/p>\n<p>BIT8: Number of expansion module exceeds the scope<\/p>\n<p>BIT9: System STACK Error<\/p>\n<p>BIT10: Resvered<\/p>\n<p>BIT11: Function(s) existed that CPU does not support<\/p>\n<p>BIT12: Resvered<\/p>\n<p>BIT13: Resvered<\/p>\n<p>BIT14: RTC Ready Indicator<\/p>\n<p>BIT15: System Service Error Indicator<\/p>\n<p>BIT16: PLC ID Setting State<\/p>\n<p>BIT17: Program ID Setting State<\/p>\n<p>BIT18: Mian Program Password Setup State<\/p>\n<p>BIT19: Subroutine Password Setup State<\/p>\n<p>BIT20: PLC Upload Password Setup State<\/p>\n<p>BIT21: PLC Download Password Setup State<\/p>\n<p>BIT22: CIC Setup State<\/p>\n<p>BIT23: Resvered<\/p>\n<p>BIT24: Resvered <\/p>\n<p>BIT25~29: System Check Code Error Indicator<\/p>\n<p>BIT30: Switch State<\/p>\n<p>BIT31: Resvered<\/p>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35363<\/p>\n<\/th>\n<th colspan=\"3\">\n<p>PLC station number\u00a0display or setup<\/p>\n<p>PLC_STATION_NUM<\/p>\n<\/th>\n<th>\n<ul>\n<li>If high byte is not equal 55H, R35363 will show the station number of this PLC.<\/li>\n<li>When the high byte of register R35363 is equal to 55H, the low byte of R35363 is used to set the station number of this PLC.<\/li>\n<\/ul>\n<\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35364<\/p>\n<\/th>\n<th colspan=\"3\">\n<p>PLC OS Version (MAJOR NO.)<\/p>\n<p>PLC_OS_VER_MAJOR<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th>\n<p>R35365<\/p>\n<\/th>\n<th colspan=\"3\">\n<p>PLC OS Version (MINOR NO + PATCH NO) <\/p>\n<p>PLC_OS_VER_MINOR<\/p>\n<p>PLC_OS_VER_PATCH<\/p>\n<\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>R35366<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Host model information (UNIT ID + MODEL)<\/p>\n<p>MAIN_UNIT_MODEL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35367<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Power ON Delay (0.01s unit) <\/p>\n<p>POWER_ON_DELAY<\/p>\n<\/td>\n<td>\n<ul>\n<li>PLC is ready for I\/O service after this delay time while power up. The unit is in 0.01S. The default value is 100.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35368<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Power Off Counter<\/p>\n<p>POWER_OFF_COUNTER<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35369<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35370<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current Scan Time  <\/p>\n<p>SCAN_TIME_CURRENT<\/p>\n<\/td>\n<td rowspan=\"3\">\n<ol>\n<li>1. Error &lt; \u00b11ms<\/li>\n<li>2. Re-calculate when PLC changes from STOP to RUN<\/li>\n<\/ol>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35371<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Maximum Scan Time<\/p>\n<p>SCAN_TIME_MAX<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35372<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Minimum scan time <\/p>\n<p>SCAN_TIME_MIN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35373<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Fixed Scan Time<\/p>\n<p>SCAN_TIME_SETTING<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35374<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Expansion Module Heart Beat Detection (Rack 1)<\/p>\n<p>EXP_HEARTBEAT_RACK1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35375<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Expansion Module Heart Beat Detection (Rack 2)<\/p>\n<p>EXP_HEARTBEAT_RACK2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35376<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Expansion Module Heart Beat Detection (Rack 3)<\/p>\n<p>EXP_HEARTBEAT_RACK3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35377<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Expansion Module Heart Beat Detection (Rack 4)<\/p>\n<p>EXP_HEARTBEAT_RACK4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35378<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Number of expansion AI points<\/p>\n<p>EXP_AI_POINTS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35379<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Number of expansion AO points<\/p>\n<p>EXP_AO_POINTS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35380<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Number of expansion DI points <\/p>\n<p>EXP_DI_POINTS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35381<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Number of expansion DO points <\/p>\n<p>EXP_DO_POINTS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35382<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port IP Address OCT1 (Leading)<\/p>\n<p>ETH_IP_OCT1<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35383<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port IP Address OCT2<\/p>\n<p>ETH_IP_OCT2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35384<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port IP Address OCT3<\/p>\n<p>ETH_IP_OCT3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35385<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port IP Address OCT4<\/p>\n<p>ETH_IP_OCT4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35386<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Mask OCT1 (Leading)<\/p>\n<p>ETH_SUBMASK_OCT1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35387<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Mask OCT2<\/p>\n<p>ETH_SUBMASK_OCT2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35388<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Mask OCT3<\/p>\n<p>ETH_SUBMASK_OCT3 <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35389<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Mask OCT4<\/p>\n<p>ETH_SUBMASK_OCT4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35390<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Router OCT1 (Leading)<\/p>\n<p>ETH_GATEWAY_OCT1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35391<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Router OCT2<\/p>\n<p>ETH_GATEWAY_OCT2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35392<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Router OCT3<\/p>\n<p>ETH_GATEWAY_OCT3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35393<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Port Router OCT4<\/p>\n<p>ETH_GATEWAY_OCT4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35394<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Primary DNS OCT1 (Leading)<\/p>\n<p>ETH_PRIM_DNS_OCT1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35395<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Primary DNS OCT2<\/p>\n<p>ETH_PRIM_DNS_OCT2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35396<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Primary DNS OCT3<\/p>\n<p>ETH_PRIM_DNS_OCT3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35397<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Primary DNS OCT4<\/p>\n<p>ETH_PRIM_DNS_OCT4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35398<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Secondary DNS OCT1(Leading)<\/p>\n<p>ETH_SEC_DNS_OCT1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35399<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Secondary DNS OCT2<\/p>\n<p>ETH_SEC_DNS_OCT2<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35400<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Secondary DNS OCT3<\/p>\n<p>ETH_SEC_DNS_OCT3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35401<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>CPU Ethernet Secondary DNS OCT4<\/p>\n<p>ETH_SEC_DNS_OCT4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35402<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Y Starting Address<\/p>\n<p>MODBUS_COIL_ADDR_Y<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35403<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_Y<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35404<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_Y<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35405<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: X Starting Address<\/p>\n<p>MODBUS_ COIL_ADDR_X<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35406<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_X<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35407<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_X<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35408<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: M Starting Address<\/p>\n<p>MODBUS_ COIL_ADDR_M<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35409<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_M<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35410<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_M<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35411<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: S Starting Address<\/p>\n<p>MODBUS_ COIL_ADDR_S<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35412<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_S<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35413<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_S<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35414<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: T starting address<\/p>\n<p>MODBUS_ COIL_ADDR_T<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35415<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_T<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35416<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_T<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35417<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: C Starting Address<\/p>\n<p>MODBUS_ COIL_ADDR_C<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35418<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Coil Starting Address<\/p>\n<p>MODBUS_COIL_C<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35419<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_ COIL_TOTALS_C<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35420<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: R Starting Address<\/p>\n<p>MODBUS _HOLDING_ADDR_R<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35421<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Holding Starting Address<\/p>\n<p>MODBUS_HOLDING_R<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35422<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS_HOLDING _TOTALS_R<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35423<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: D Starting Address<\/p>\n<p>MODBUS _HOLDING_ADDR_D<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35424<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Holding Starting Address<\/p>\n<p>MODBUS_HOLDING_D<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35425<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS _HOLDING_TOTALS_D<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35426<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: RT Starting Address<\/p>\n<p>MODBUS _HOLDING_ADDR_RT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35427<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Holding Starting Address<\/p>\n<p>MODBUS_HOLDING_RT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35428<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS _HOLDING_TOTALS_RT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35429<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: RC Starting Address<\/p>\n<p>MODBUS _HOLDING_ADDR_RC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35430<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Holding Starting Address<\/p>\n<p>MODBUS_HOLDING_RC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35431<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS _HOLDING_TOTALS_RC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35432<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: LC Starting Address<\/p>\n<p>MODBUS _HOLDING_ADDR_DRC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35433<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Holding Starting Address<\/p>\n<p>MODBUS_HOLDING_DRC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35434<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Modbus: Corresponding Length<\/p>\n<p>MODBUS _HOLDING_TOTALS_DRC<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35435<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 0 Cycle Setting<\/p>\n<p>STM0_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35436<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 0 Current Time<\/p>\n<p>STM0_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35437<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 1 Cycle Setting<\/p>\n<p>STM1_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35438<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 1 Current Time<\/p>\n<p>STM1_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35439<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 2 Cycle Setting<\/p>\n<p>STM2_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35440<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 2 Current Time<\/p>\n<p>STM2_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35441<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 3 Cycle Setting<\/p>\n<p>STM3_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35442<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>1ms Timer STM 3 Current Time<\/p>\n<p>STM3_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35443<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 ms Timer STM 0 Cycle Setting<\/p>\n<p>LTM0_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35444<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 msTimer STM 0 Current Time<\/p>\n<p>LTM0_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35445<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 ms Timer STM 1 Cycle Setting<\/p>\n<p>LTM1_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35446<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 msTimer STM 1 Current Time<\/p>\n<p>LTM1_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35447<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 ms Timer STM 2 Cycle Setting<\/p>\n<p>LTM2_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35448<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 msTimer STM 2 Current Time<\/p>\n<p>LTM2_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35449<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 ms Timer STM 3 Cycle Setting<\/p>\n<p>LTM3_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35450<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>10 msTimer STM 3 Current Time<\/p>\n<p>LTM3_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35451<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 0 Cycle Setting LOW WORD<\/p>\n<p>HST0_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35452<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 0 Cycle Setting HIGH WORD<\/p>\n<p>HST0_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35453<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 0 Current Time LOW WORD<\/p>\n<p>HST0_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35454<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 0 Current Time HIGH WORD<\/p>\n<p>HST0_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35455<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 1 Cycle Setting LOW WORD<\/p>\n<p>HST1_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35456<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 1 Cycle Setting HIGH WORD<\/p>\n<p>HST1_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35457<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 1 Current Time LOW WORD<\/p>\n<p>HST1_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35458<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 1 Current Time HIGH WORD<\/p>\n<p>HST1_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35459<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 2 Cycle Setting LOW WORD<\/p>\n<p>HST2_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35460<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 2 Cycle Setting HIGH WORD<\/p>\n<p>HST2_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35461<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 2 Current Time LOW WORD<\/p>\n<p>HST2_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35462<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 2 Current Time HIGH WORD<\/p>\n<p>HST2_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35463<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 3 Cycle Setting LOW WORD<\/p>\n<p>HST3_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35464<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 3 Cycle Setting HIGH WORD<\/p>\n<p>HST3_PV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35465<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 3 Current Time LOW WORD<\/p>\n<p>HST3_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35466<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms Timer HST 3 Current Time HIGH WORD<\/p>\n<p>HST3_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35467<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms HSTA HSTA Current Count LOW WORD<\/p>\n<p>HSTA_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35468<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>0.1ms HSTA HSTA Current Count HIGH WORD<\/p>\n<p>HSTA_CV<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35469-<\/p>\n<p>R35478<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>It is used for designating the Data Register that should be replicated in the SD Card for reading, and the user needs to create such field before replicating the SD Card. After turning on the PC, it will execute the required action according to SR18~SR27 that have been replicated in the SD Card.<\/p>\n<p>SD_GROUP_FLAG<\/p>\n<p>SD_GROUP_COUNT<\/p>\n<p>SD_GROUP_LEN1<\/p>\n<p>SD_GROUP_ADDR1<\/p>\n<p>SD_GROUP_LEN2<\/p>\n<p>SD_GROUP_ADDR2<\/p>\n<p>SD_GROUP_LEN3<\/p>\n<p>SD_GROUP_ADDR3<\/p>\n<p>SD_GROUP_LEN4<\/p>\n<p>SD_GROUP_ADDR4<\/p>\n<\/td>\n<td>\n<p>When using ROM Pack to save the Ladder program and the data register, this table should be used to determine the registers that should be replicated. When turning on the PC, it will be read by ROM Pack for executing the required initialization procedure.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35479<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Control the register to be read by SD Card. Determine if the data register in the PACK should be read when turning on the PC.<\/p>\n<p>SD_GROUP_LOAD_FLAG<\/p>\n<\/td>\n<td>\n<p>=5530H: When turning on the PC, it will not read the data register that has been replicated to ROM Pack. <\/p>\n<p>= Other value: When turning on the PC, the content of the data register being replicated to ROM Pack will be initialized as the value when the register is replicated.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35480<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Test-run modification mode or replicate the SD Card related command and the state<\/p>\n<p>SD_STATE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35481<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>User-defined TCP port of\u00a0Fatek binary server<\/p>\n<p>ETH_FATEK_CUSTOM_PORT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35482<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>User-defined TCP port of\u00a0Modbus TCP server<\/p>\n<p>ETH_MODBUS_CUSTOM_PORT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35483<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>iMonitor Connection Status<\/p>\n<p>IMONITOR_STATUS<\/p>\n<\/td>\n<td>\n<p>0: Offline<\/p>\n<p>1: Online<\/p>\n<p>2: Connecting<\/p>\n<p>Others: Error code<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35484-<\/p>\n<p>R35486<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Host MAC address<\/p>\n<p>SYS_MAC1<\/p>\n<p>SYS_MAC2<\/p>\n<p>SYS_MAC3<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35487-<\/p>\n<p>R35643<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reserve<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35644<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>SD Operation Information Word Group<\/p>\n<p>High byte: State Code<\/p>\n<p>Low byte: Operation Code\u00a0<\/p>\n<p>SD_OPERATION_STATUS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35645<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Build-in Analog Input Channel 0 Read Value (M2 Type)<\/p>\n<p>PLC_AI0<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35646<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Build-in Analog Input Channel 1 Read Value (M2 Type)<\/p>\n<p>PLC_AI1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35647<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Error code of PSO 4<\/p>\n<p>PSO4_ERR_CODE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35648<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Error code of PSO 5<\/p>\n<p>PSO5_ERR_CODE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35649<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Error code of PSO 6<\/p>\n<p>PSO6_ERR_CODE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35650<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Error code of PSO 7<\/p>\n<p>PSO7_ERR_CODE<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35651<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Completed step number of positioning program for PSO4<\/p>\n<p>PSO4_DN_STEP_NUM<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35652<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Completed step number of positioning program for PSO5<\/p>\n<p>PSO5_DN_STEP_NUM<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35653<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Completed step number of positioning program for PSO6<\/p>\n<p>PSO6_DN_STEP_NUM<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35654<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Completed step number of positioning program for PSO7<\/p>\n<p>PSO7_DN_STEP_NUM<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35655<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for Low Word of PSO4<\/p>\n<p>PSO4_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35656<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for High Word of PSO4<\/p>\n<p>PSO4_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35657<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for Low Word of PSO5<\/p>\n<p>PSO5_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35658<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for High Word of PSO5<\/p>\n<p>PSO5_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35659<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for Low Word of PSO6<\/p>\n<p>PSO6_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35660<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for High Word of PSO6<\/p>\n<p>PSO6_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35661<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for Low Word of PSO7<\/p>\n<p>PSO7_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35662<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Output frequency for High Word of PSO7<\/p>\n<p>PSO7_CUR_FREQ<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35663 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for Low Word of PSO4<\/p>\n<p>PSO4_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35664 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for High Word of PSO4<\/p>\n<p>PSO4_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35665 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for Low Word of PSO5<\/p>\n<p>PSO5_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35666 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for High Word of PSO5<\/p>\n<p>PSO5_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35667 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for Low Word of PSO6<\/p>\n<p>PSO6_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35668 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for High Word of PSO6<\/p>\n<p>PSO6_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35669<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for Low Word of PSO7<\/p>\n<p>PSO7_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35670 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Current pulse position for High Word of PSO7<\/p>\n<p>PSO7_CUR_POS<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35671 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for Low Word of PSO4<\/p>\n<p>PSO4_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35672 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for High Word of PSO4<\/p>\n<p>PSO4_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35673 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for Low Word of PSO5<\/p>\n<p>PSO5_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35674 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for High Word of PSO5<\/p>\n<p>PSO5_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35675 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for Low Word of PSO6<\/p>\n<p>PSO6_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35676<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for High Word of PSO6<\/p>\n<p>PSO6_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35677<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for Low Word of PSO7<\/p>\n<p>PSO7_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35678<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Pulse count remaining for output for High Word of PSO7<\/p>\n<p>PSO7_REMAINING_COUNT<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35679<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>MQTT Connection Status<\/p>\n<p>MQTT_STATUS<\/p>\n<\/td>\n<td>\n<p>MQTT_CONNECT_ACCEPTED = 0,<\/p>\n<p>MQTT_CONNECT_REFUSED_PROTOCOL_VERSION = 1,<\/p>\n<p>MQTT_CONNECT_REFUSED_IDENTIFIER = 2,<\/p>\n<p>MQTT_CONNECT_REFUSED_SERVER = 3,<\/p>\n<p>MQTT_CONNECT_REFUSED_USERNAME_PASS = 4,<\/p>\n<p>MQTT_CONNECT_REFUSED_NOT_AUTHORIZED_ = 5,<\/p>\n<p>MQTT_CONNECT_DISCONNECTED = 256,<\/p>\n<p>MQTT_CONNECT_TIMEOUT = 257<\/p>\n<p>MQTT_CONNECT_MEMORY_LACK = 258<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35680~<\/p>\n<p>R35760<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35761<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Able to dynamically change the high-speed pulse output frequency<\/p>\n<p>HSPO_FREQ_CTRL<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35762<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>COM2 high-speed network enable\/mode<\/p>\n<\/td>\n<td>\n<p>Low Bit=55H, High-speed slave station enable        <\/p>\n<p>=Others, Disabled<\/p>\n<p>High Bit=55H, High-speed master station communication with one-table cycle             =Others, Continuous<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35763<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>COM2 Receive\/Transmit Timeout Setting (High-Speed)<\/p>\n<p>COM_RX_TX_TIME_P2H<\/p>\n<\/td>\n<td>\n<p>When the value of the high byte is not 56H, the system will generate appropriate settings based on the communication parameters set in R4161, and the user does not need to configure them.<\/p>\n<p>When the value of the high byte is 56H, the low byte is reserved for manual settings when the system configuration does not meet the requirements of use.R4160[5-0] : Reserve<\/p>\n<p>R4160[7-6]\uff1aSet TX TMO, =0, 500us ; =1, 700us ; =2, 900us ; =3, 1100us <\/p>\n<p>M PLC high-speed communication Baud Rate and the automatic setting for Rx\/Tx time out values is as follows:<\/p>\n<p>For reference:<\/p>\n<p>Baud Rate = 38400, Rx = 8 bit time , Tx = 700us<\/p>\n<p>Baud Rate = 153600, Rx = 16 bit time , Tx = 700us<\/p>\n<p>Baud Rate = 614400, Rx = 20 bit time , Tx = 700us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35764<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Type of FUN30 system analog value bit<\/p>\n<p>PID_AI_RESOLUTION<\/p>\n<\/td>\n<td>\n<p>=0, 12bit<\/p>\n<p>=1, 14bit<\/p>\n<p>=Other, Nbit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35765<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Gain constant of FUN30<\/p>\n<p>PID_GAIN<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35766<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp0 vector speed for Low Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35767<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp0 vector speed for High Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35768<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp1 vector speed for Low Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35769<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp1 vector speed for High Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35770<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp2 vector speed for Low Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35771<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp2 vector speed for High Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35772<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp3 vector speed for Low Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35773<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp3 vector speed for High Word<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35774<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp0 error code<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35775<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp1 error code<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35776<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp2 error code<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35777<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FUN147 Gp3 error code<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35778<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>The step number (positioning point) which has been completed of FUN147 Gp0.<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35779<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>The step number (positioning point) which has been completed of FUN147 Gp1.<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35780<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>The step number (positioning point) which has been completed of FUN147 Gp2.<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35781<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>The step number (positioning point) which has been completed of FUN147 Gp3.<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35782~<\/p>\n<p>R35797<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35798<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>COM3 Communication Parameters Setting<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35799\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>COM4 Communication Parameters Setting<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35800\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>COM3 and COM4 connection setting<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35801\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Communication protocol setting for COM3 and COM4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35802\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reply delay time settings for COM3 and COM4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35803\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Transmission delay and reception error detection time setting when COM3 is used as the master station<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35804\u00a0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Transmission delay and reception error detection time setting when COM4 is used as the master station<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35805~<\/p>\n<p>R35821<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35822~<\/p>\n<p>R35871<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Expansion module calibration reserved registers<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R35872~<\/p>\n<p>R36871<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Starting register of expansion module status<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36872~<\/p>\n<p>R36879<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>TEST RUN Reserve Register (Read-Only)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36880~<\/p>\n<p>R36979<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>For Motion related special Registers<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36980-<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Motion axis data start (read-only)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R43194~<\/p>\n<p>R43213<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>P0 (R43194), Reserved(R43195), <\/p>\n<p>P1(R43196), Reserved(R43197),<\/p>\n<p>P2(R43198), &#8230; P9 (R43212), Reserved(R43213)<\/p>\n<p>INDEX_P0<\/p>\n<p>INDEX_P1<\/p>\n<p>INDEX_P2<\/p>\n<p>INDEX_P3<\/p>\n<p>INDEX_P4<\/p>\n<p>INDEX_P5<\/p>\n<p>INDEX_P6<\/p>\n<p>INDEX_P7<\/p>\n<p>INDEX_P8<\/p>\n<p>INDEX_P9<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R43214<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>V<\/p>\n<p>INDEX_V<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>R43216<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Z<\/p>\n<p>INDEX_Z<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>2-5  Motion Special Relay Details<\/h3>\n<p>\u203b For more detailed information, please refer to MPLC Motion User Manual Chapter 2\u301dMotion Parameters and Status (Special Register and Relay)\u301e<\/p>\n<p>\u203b The table lists the register numbers for axis 1, and for each subsequent axis, the register number is obtained by adding 40*(n-1), &#8216;n&#8217; represents the axis number.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Relay No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>M10520<\/p>\n<\/td>\n<td>\n<p>All axes: Servo ON<\/p>\n<\/td>\n<td>\n<p>ALL_SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10521<\/p>\n<\/td>\n<td>\n<p>All axes: Servo Reset<\/p>\n<\/td>\n<td>\n<p>ALL_SERVO_FAULT_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10522<\/p>\n<\/td>\n<td>\n<p>Write all mapping parameters during initialization.<\/p>\n<\/td>\n<td>\n<p>MAPPING_ALL_PARM_AFTER_INIT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10523<\/p>\n<\/td>\n<td>\n<p>Motion control card restart.<\/p>\n<\/td>\n<td>\n<p>RESTART_MOTION_CARD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10524<\/p>\n<\/td>\n<td>\n<p>Custom PDO packet for special registers<\/p>\n<\/td>\n<td>\n<p>ENABLE_CUSTOM_PDO<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10600 + 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis control command: Servo ON<\/p>\n<\/td>\n<td>\n<p>SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10601+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis control command: Fault Reset<\/p>\n<\/td>\n<td>\n<p>FAULT_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10602+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis control command: Deceleration Stop<\/p>\n<\/td>\n<td>\n<p>DEC_STOP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10603+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis control command: Emergency stop<\/p>\n<\/td>\n<td>\n<p>EMG_STOP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10604+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch ON<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10605+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Origin On<\/p>\n<\/td>\n<td>\n<p>ORIG_SIG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10606+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(+) on<\/p>\n<\/td>\n<td>\n<p>LIM_POS_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10607+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(-) on<\/p>\n<\/td>\n<td>\n<p>LIM_NEG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10608+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Z Count Signal<\/p>\n<\/td>\n<td>\n<p>Z_SIG_IN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10609+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch ON Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_ON_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10610+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous main clutch OFF Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_OFF_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10611+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch ON<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10612+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch ON Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_ON_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10613+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronous auxiliary clutch OFF Disable<\/p>\n<\/td>\n<td>\n<p>SYNC_AUX_CLU_OFF_DIS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10614+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10615+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10616+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10617+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 Function ON<\/p>\n<\/td>\n<td>\n<p>PROBE1_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10618+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 Function Reset<\/p>\n<\/td>\n<td>\n<p>PROBE1_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10619+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 Function ON<\/p>\n<\/td>\n<td>\n<p>PROBE2_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10620+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 Function Reset<\/p>\n<\/td>\n<td>\n<p>PROBE2_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10621+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Parameter Immediate Effect Request<\/p>\n<\/td>\n<td>\n<p>SYNC_PARM_UP_IMMED<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10622+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Synchronization Parameter Next Period Effect Request<\/p>\n<\/td>\n<td>\n<p>SYNC_PARM_UP_NEXT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10623+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Syncronizationc Clutch Edge Trigger Buffer On<\/p>\n<\/td>\n<td>\n<p>SYNC_MAIN_CLU_BUF_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10624+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Initialization of the Cam phase when the axis synchronous clutch is OFF<\/p>\n<\/td>\n<td>\n<p>ECAM_PHASE_RST<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10625+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Rotation Angle Choose Near<\/p>\n<\/td>\n<td>\n<p>ROT_ANG_NEAR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10626+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Rotation Angle Target Direction<\/p>\n<\/td>\n<td>\n<p>ROT_ANG_DIR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10627+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Syncronizationc Mode ON<\/p>\n<\/td>\n<td>\n<p>SYNC_MODE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10628+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Pause Current Action<\/p>\n<\/td>\n<td>\n<p>PAUSE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10629+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>High speed homing mode ON<\/p>\n<\/td>\n<td>\n<p>HOM_SKIP_EN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10630+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis specifies current coordinates<\/p>\n<\/td>\n<td>\n<p>SET_CUR_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10631+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis operation mode ON<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10632+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis operation mode unit<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_UNIT_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10633+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis operation mode absolute coordinates<\/p>\n<\/td>\n<td>\n<p>ADV_MODE_COOR_ABS_OR_REF_MASK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M10634+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Main clutch phase inout display<\/p>\n<\/td>\n<td>\n<p>MAIN_CLUTCH_PHASE_INOUT_DISPLAY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11240+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Servo On<\/p>\n<\/td>\n<td>\n<p>IS_SERVO_ON<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11241+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Operation Ready<\/p>\n<\/td>\n<td>\n<p>IS_OP_READY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11242+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis error in progress<\/p>\n<\/td>\n<td>\n<p>IS_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11243+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis warning in progress<\/p>\n<\/td>\n<td>\n<p>IS_WARN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11244+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Control in progress<\/p>\n<\/td>\n<td>\n<p>IS_CTRL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11245+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Homing in progress<\/p>\n<\/td>\n<td>\n<p>IS_HOM_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11246+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Homing done<\/p>\n<\/td>\n<td>\n<p>IS_HOM_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11247+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Positioning in progress<\/p>\n<\/td>\n<td>\n<p>IS_MOV_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11248+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Positioning done<\/p>\n<\/td>\n<td>\n<p>IS_MOV_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11249+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>JOG in progress<\/p>\n<\/td>\n<td>\n<p>IS_JOG_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11250+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>JOG done<\/p>\n<\/td>\n<td>\n<p>IS_JOG_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11251+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Synchronizing in progress<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11252+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Synchronizing done<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11253+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Speed mode in progress<\/p>\n<\/td>\n<td>\n<p>IS_VEL_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11254+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Speed mode done<\/p>\n<\/td>\n<td>\n<p>IS_VEL_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11255+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Torque mode in progress<\/p>\n<\/td>\n<td>\n<p>IS_TORQ_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11256+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Torque mode done<\/p>\n<\/td>\n<td>\n<p>IS_TORQ_DN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11257+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis soft limit(+) status<\/p>\n<\/td>\n<td>\n<p>IS_SOFT_LIM_POS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11258+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis soft limit(-) status<\/p>\n<\/td>\n<td>\n<p>IS_SOFT_LIM_NEG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11259+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis origin limit status<\/p>\n<\/td>\n<td>\n<p>IS_ORIG_SIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11260+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(+) status<\/p>\n<\/td>\n<td>\n<p>IS_LIM_POS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11261+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis limit(-) status<\/p>\n<\/td>\n<td>\n<p>IS_LIM_NEG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11262+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 1 triggered<\/p>\n<p>state<\/p>\n<\/td>\n<td>\n<p>IS_PROBE1_TRIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11263+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Probe 2 triggered<\/p>\n<p>state<\/p>\n<\/td>\n<td>\n<p>IS_PROBE2_TRIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11264+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis synchronization parameter effective state<\/p>\n<\/td>\n<td>\n<p>IS_SYNC_PARM_UPDN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11265+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis tracking error state<\/p>\n<\/td>\n<td>\n<p>IS_FOLLOW_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11266+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Pause Status<\/p>\n<\/td>\n<td>\n<p>IS_PAUSE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11267+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Homing mode Z-phase signal<\/p>\n<\/td>\n<td>\n<p>IS_Z_SIG<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11268+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis operation mode action<\/p>\n<\/td>\n<td>\n<p>IS_ADV_ACT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M11269+ 40*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis operation mode done<\/p>\n<\/td>\n<td>\n<p>IS_ADV_DN<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Motion special relay list<\/p>\n<p>\u203bAll special relays do not provide TU and TD differential contact commands (TU\u3001TD)\uff0cIf it is necessary to perform differential action on the special relay, it can be replaced by an indirect method. (Refer to the picture below)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-02\/mplc-m07-en-02-007.png\" \/><\/p>\n<p>special relays use TD\/TD by an indirect method<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Note: Those marked with \u201c\u25e4\u201d in special relays and temporary registers are forbidden to be written. Meanwhile, this kind of relays are still prohibited\/disabling control and forced setting, and TU and TD contacts are not provided.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>2-6  Motion Special Register Details<\/h3>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Relay No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>R36880<\/p>\n<\/td>\n<td>\n<p>Motion controller state<\/p>\n<\/td>\n<td>\n<p>UNIT_STATE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36881<\/p>\n<\/td>\n<td>\n<p>Motion controller error code<\/p>\n<\/td>\n<td>\n<p>UNIT_ERR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36882<\/p>\n<\/td>\n<td>\n<p>Unit Program State<\/p>\n<\/td>\n<td>\n<p>UNIT_PROGRAM_STATE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36883<\/p>\n<\/td>\n<td>\n<p>Unit Error Code<\/p>\n<\/td>\n<td>\n<p>UNIT_ERR_CODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36884 &#8211; 36903<\/p>\n<\/td>\n<td>\n<p>Current Step<\/p>\n<\/td>\n<td>\n<p>CURRENT_STEP_1 &#8211; CURRENT_STEP_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36904 &#8211; 36923<\/p>\n<\/td>\n<td>\n<p>Current Block State<\/p>\n<\/td>\n<td>\n<p>CURRENT_BLOCK_STATE_1 &#8211; CURRENT_BLOCK_STATE_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36924 &#8211; 36943<\/p>\n<\/td>\n<td>\n<p>Flow State ID<\/p>\n<\/td>\n<td>\n<p>FLOW_STATE_ID_1 &#8211; FLOW_STATE_ID_20<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR36964 &#8211; 36970<\/p>\n<\/td>\n<td>\n<p>Encoder value<\/p>\n<\/td>\n<td>\n<p>ENCODER_VALUE_2 &#8211; ENCODER_VALUE_4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR36972<\/p>\n<\/td>\n<td>\n<p>Gray code encoder value <\/p>\n<\/td>\n<td>\n<p>GRAY_CODE_ENCODER_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR36974<\/p>\n<\/td>\n<td>\n<p>Gray code encoder turns <\/p>\n<\/td>\n<td>\n<p>GRAY_CODE_ENCODER_TURNS<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u203b The table lists the register numbers for axis 1, and for each subsequent axis, the register number is obtained by adding 150*(n-1), &#8216;n&#8217; represents the axis number.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p><strong>Relay No.<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>Function<\/strong><\/p>\n<\/th>\n<th>\n<p><strong>System Tag Symbol<\/strong><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>R36980 + 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis properties<\/p>\n<\/td>\n<td>\n<p>TYPE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R36984+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Current Control Mode<\/p>\n<\/td>\n<td>\n<p>CTRL_MODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37004+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Error Detail Information 1<\/p>\n<\/td>\n<td>\n<p>ERR_INFO_1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37005+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Error Detail Information 2<\/p>\n<\/td>\n<td>\n<p>ERR_INFO_2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37006+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Warning Detail Information 1<\/p>\n<\/td>\n<td>\n<p>WARN_INFO_1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37007+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Warning Detail Information 2<\/p>\n<\/td>\n<td>\n<p>WARN_INFO_2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37012+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Control<\/p>\n<\/td>\n<td>\n<p>CTRL_STATUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37013+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Warning Code<\/p>\n<\/td>\n<td>\n<p>WARN_STATUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37014+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Command Coordinate <\/p>\n<\/td>\n<td>\n<p>CMD_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37016+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Command Speed<\/p>\n<\/td>\n<td>\n<p>CMD_VEL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37018+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Command Position<\/p>\n<\/td>\n<td>\n<p>CMD_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37020+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Positioning Current Point No.<\/p>\n<\/td>\n<td>\n<p>CUR_PT_OR_ECAM_NUM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37021+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Current Coordinate<\/p>\n<\/td>\n<td>\n<p>CUR_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37023+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Feedback Speed Monitor<\/p>\n<\/td>\n<td>\n<p>CUR_VEL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37025+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Position Deviation Monitor <\/p>\n<\/td>\n<td>\n<p>CUR_COOR_DEV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37027+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Digital Input from Driver<\/p>\n<\/td>\n<td>\n<p>SERVO_DI_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37029+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Current Flow ID<\/p>\n<\/td>\n<td>\n<p>CUR_FLOW_NUM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37030+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Contact Output <\/p>\n<\/td>\n<td>\n<p>SYNC_CONT_OUT<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37032+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Current Torque<\/p>\n<\/td>\n<td>\n<p>CUR_TORQ<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37033+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>E-Cam Input Phase<\/p>\n<\/td>\n<td>\n<p>ECAM_IN_PHASE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37035+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Origin Position <\/p>\n<\/td>\n<td>\n<p>ORG_PLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R37037 &#8211; R37039+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis Status Word 1-3<\/p>\n<\/td>\n<td>\n<p>CONTROL_STATUS_WORD1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37040+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Main Clutch Output Phase <\/p>\n<\/td>\n<td>\n<p>MAIN_CLU_INOUT_PHASE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37042+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Probe 1 Coordinate<\/p>\n<\/td>\n<td>\n<p>PROBE1_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37044+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Probe 2 Coordinate<\/p>\n<\/td>\n<td>\n<p>PROBE2_COOR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37050+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis specifies coordinates<\/p>\n<\/td>\n<td>\n<p>SET_COOR_VALUE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37052+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced control mode<\/p>\n<\/td>\n<td>\n<p>SET_ADV_MODE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37054+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 1<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37056+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 2<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37058+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 3<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37060+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 4<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37062+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 5<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37064+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 6<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DR37066+ 150*(n-1)<\/p>\n<\/td>\n<td>\n<p>Axis advanced mode instruction 7<\/p>\n<\/td>\n<td>\n<p>SET_ADV_CMD7<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Table 1 Motion special register list<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chapter 2. Configuration of memory, single point (Digit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[51],"tags":[],"class_list":["post-3268","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m07"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3268"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3268\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3268"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3268"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}