{"id":3269,"date":"2026-11-17T18:39:57","date_gmt":"2026-11-17T10:39:57","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m07-en-03\/"},"modified":"2026-11-17T18:39:57","modified_gmt":"2026-11-17T10:39:57","slug":"mplc-m07-en-03","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/mplc-m07-en-03\/","title":{"rendered":"Chapter 3. M PLC Instruction Lists"},"content":{"rendered":"<h3>3-1  Sequential Instructions<\/h3>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>Operand<\/p>\n<\/th>\n<th>\n<p>Symbol<\/p>\n<\/th>\n<th>\n<p>Function<\/p>\n<\/th>\n<th>\n<p>Instruction Type<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"4\">\n<p>X,Y,M,<\/p>\n<p>S,T,C<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-001.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a normally open (A) contact<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Network starting<\/p>\n<p>instructions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-002.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a normally closed (B) contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-003.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a differential up (TU) contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-004.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a differential down (TD) contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-005.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a open circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-006.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a network with a short circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>X,Y,M,<\/p>\n<p>S,T,C<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-007.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch<\/p>\n<p>line with a normally open contact<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Origin or branch line starting instructions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-008.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch <\/p>\n<p>line with a normally closed contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-009.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch<\/p>\n<p>line with a differential up contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-010.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch<\/p>\n<p>line with a differential down contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-011.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch<\/p>\n<p>line with a open circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-012.png\" \/><\/p>\n<\/td>\n<td>\n<p>Starting a relay circuit from origin or branch<\/p>\n<p>line with a short circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>X,Y,M,<\/p>\n<p>S,T,C<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-013.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of normally open contact<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Serial connection instructions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-014.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of normally close contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-015.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of differential up contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-016.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of differential down contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-017.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of open circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-018.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of short circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>X,Y,M,<\/p>\n<p>S,T,C<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-019.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of normally open contact<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Parallel connection instructions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-020.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of normally closed contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-021.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of differential up contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-022.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of differential down contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-023.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of open circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-024.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of short circuit contact<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-025.png\" \/><\/p>\n<\/td>\n<td>\n<p>Serial connection of two circuit blocks<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Blocks merge instructions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-026.png\" \/><\/p>\n<\/td>\n<td>\n<p>Parallel connection of two circuit blocks<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Y,M,S<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-027.png\" \/><\/p>\n<\/td>\n<td>\n<p>Send result to coil<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Coil output instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-028.png\" \/><\/p>\n<\/td>\n<td>\n<p>Send inverted result to coil<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-029.png\" \/><\/p>\n<\/td>\n<td>\n<p>Send result to an external output coil and appoint it as of retentive type<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>TR<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>Save the node status to a temporary relay<\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Node operation instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Load the temporary relay<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-030.png\" \/><\/p>\n<\/td>\n<td>\n<p>Take the transition up of the node status<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-031.png\" \/><\/p>\n<\/td>\n<td>\n<p>Take the transition down of the node status<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-032.png\" \/><\/p>\n<\/td>\n<td>\n<p>Invert the node status<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-033.png\" \/><\/p>\n<\/td>\n<td>\n<p>Set a coil<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/mplc-m07-en-03\/mplc-m07-en-03-034.png\" \/><\/p>\n<\/td>\n<td>\n<p>Reset a coil<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>sequential instructions list<\/p>\n<p>\u203bThe 36 sequential instructions listed above are all applicable to every models of M &#8211; SERIES PLC.\t<\/p>\n<h3>3-2  Function Instructions<\/h3>\n<p>There are more than 200 different M PLC function instructions. If put the D and P derivative instructions into account, the total number of instructions is over 300. On top of these, many function instructions have multiple input controls (up to 8 inputs) which can have up to 8 different types of operation mode combinations. Hence, the size of M PLC instruction sets is in fact not smaller than that of a large PLC. Having powerful instruction functions, though may help for establishing the complicated control applications, but also may impose a heavy burden on those users of small type PLC\u2019s. For ease of use, M-Series PLC function instructions are divided into two groups, the Basic function group (The instructions attached with \u201c\u2605\u201d symbol are basic functions which amounts to 26 function instructions and 4 SFC instructions) and the advanced function group.<\/p>\n<ul>\n<li>Timer\uff0fCounter Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<thead>\n<tr>\n<th>\n<p>FUN<\/p>\n<p>No<\/p>\n<\/th>\n<th>\n<p>Name<\/p>\n<\/th>\n<th>\n<p>Operand<\/p>\n<\/th>\n<th>\n<p>Derivative Instruction<\/p>\n<\/th>\n<th>\n<p>Function descriptions<\/p>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>T nnnn<\/p>\n<\/td>\n<td>\n<p>PV<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>General timer instructions <\/p>\n<p>( \u201cnnnn\u201d range 0\uff5e1023, total 1024)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>C nnnn<\/p>\n<\/td>\n<td>\n<p>PV<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>General counter instructions <\/p>\n<p>( \u201cnnnn\u201d range 0\uff5e1279, total 1280)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 7<\/p>\n<\/td>\n<td>\n<p>UDCTR<\/p>\n<\/td>\n<td>\n<p>CV,PV<\/p>\n<\/td>\n<td>\n<p>DP<\/p>\n<\/td>\n<td>\n<p>16-Bit or 32-Bit up\/down counter<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Timer\uff0fCounter Instructions list<\/p>\n<ul>\n<li>Output Operation Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605 4<\/p>\n<\/td>\n<td>\n<p>DIFU<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>to get the up differentiation of a D relay and store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 5<\/p>\n<\/td>\n<td>\n<p>DIFD<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>to get the down differentiation of a D relay and store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260510<\/p>\n<\/td>\n<td>\n<p>TOGG<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Toggle the ON\/OFF status of the D relay<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Output Operation Instructions List<\/p>\n<ul>\n<li>Set\uff0fReset Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>SET<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>DP<\/p>\n<\/td>\n<td>\n<p>Set all bits of register or a discrete point to 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>RST<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>DP<\/p>\n<\/td>\n<td>\n<p>Clear all bits of register or a discrete point to 0<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Set\uff0fReset Instructions List<\/p>\n<ul>\n<li>SFC Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>STP<\/p>\n<\/td>\n<td>\n<p>Snnnn<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>STEP declaration<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>STPEND<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>End of the STEP program<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>TO<\/p>\n<\/td>\n<td>\n<p>Snnnn<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>STEP divergent instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605<\/p>\n<\/td>\n<td>\n<p>FROM<\/p>\n<\/td>\n<td>\n<p>Snnnn<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>STEP convergent instruction<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>SFC Instructions List<\/p>\n<ul>\n<li>Arithmetic Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u260511<\/p>\n<\/td>\n<td>\n<p>(\uff0b)<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform addition of Sa and Sb and then store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260512<\/p>\n<\/td>\n<td>\n<p>(\uff0d)<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform subtraction of Sa and Sb and then store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260513<\/p>\n<\/td>\n<td>\n<p>(\uff0a)<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform multiplication of Sa and Sb and then store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260514<\/p>\n<\/td>\n<td>\n<p>(\uff0f)<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform division of Sa and Sb and then store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260515<\/p>\n<\/td>\n<td>\n<p>(+1)<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Adds 1 to the D value<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260516<\/p>\n<\/td>\n<td>\n<p>(\u22121)<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Subtracts 1 from the D value<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>24<\/p>\n<\/td>\n<td>\n<p>SUM<\/p>\n<\/td>\n<td>\n<p>S,N,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the sum of the successive N values beginning from S and store it in D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>25<\/p>\n<\/td>\n<td>\n<p>MEAN<\/p>\n<\/td>\n<td>\n<p>S,N,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the mean average of the successive N values beginning from S and store it in D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>27<\/p>\n<\/td>\n<td>\n<p>NEG<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the 2&#8217;s complement (negative number) of the D value and store it back in D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>28<\/p>\n<\/td>\n<td>\n<p>ABS<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the absolute value of D and store it back in D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>31<\/p>\n<\/td>\n<td>\n<p>CRC16<\/p>\n<\/td>\n<td>\n<p>MD,S,N,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>CRC16 caculator <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>33<\/p>\n<\/td>\n<td>\n<p>LCNV<\/p>\n<\/td>\n<td>\n<p>Md,S,Ts,D,L<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Linear Conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>34<\/p>\n<\/td>\n<td>\n<p>MLC<\/p>\n<\/td>\n<td>\n<p>Rs,SI,Tx,Ty,TI,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Multiple Linear Conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>200<\/p>\n<\/td>\n<td>\n<p>I\u2192F<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Integer to floating point number conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>201<\/p>\n<\/td>\n<td>\n<p>F\u2192I<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Floating point number to integer conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>202<\/p>\n<\/td>\n<td>\n<p>FADD<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Addition of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>203<\/p>\n<\/td>\n<td>\n<p>FSUB<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Subtraction of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>204<\/p>\n<\/td>\n<td>\n<p>FMUL<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Multiplication of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>205<\/p>\n<\/td>\n<td>\n<p>FDIV<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Division of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>206<\/p>\n<\/td>\n<td>\n<p>FCMP<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Comparison of floating point number and then store the result to FO0\uff5eFO2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>207<\/p>\n<\/td>\n<td>\n<p>FZCP<\/p>\n<\/td>\n<td>\n<p>S,SU,SL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Comparison of floating point number S to the zones formed by the upper limit SU and the lower limit SL and then store the result to FO0\uff5eFO2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>209<\/p>\n<\/td>\n<td>\n<p>FSIN<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>SIN trigonometric function<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>210<\/p>\n<\/td>\n<td>\n<p>FCOS<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>COS trigonometric function<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>211<\/p>\n<\/td>\n<td>\n<p>FTAN<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>TAN trigonometric function<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>212<\/p>\n<\/td>\n<td>\n<p>FNEG<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Change sign of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>213<\/p>\n<\/td>\n<td>\n<p>FABS<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Take absolute value of floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>218<\/p>\n<\/td>\n<td>\n<p>FASIN<\/p>\n<\/td>\n<td>\n<p>S,D,MD<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating Point arc sine<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>219<\/p>\n<\/td>\n<td>\n<p>FACOS<\/p>\n<\/td>\n<td>\n<p>S,D,MD<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating Point arc cosine<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>226<\/p>\n<\/td>\n<td>\n<p>MOD<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Modulo (Remainder)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Arithmetic Instructions List<\/p>\n<ul>\n<li>Logic Operation Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u260518<\/p>\n<\/td>\n<td>\n<p>AND<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform logical AND for Sa and Sb and store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u260519<\/p>\n<\/td>\n<td>\n<p>OR<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Perform logical OR for Sa and Sb and store the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>35<\/p>\n<\/td>\n<td>\n<p>XOR<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the result of the Exclusive OR logical operation made between Sa and Sb, and store it in D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>36<\/p>\n<\/td>\n<td>\n<p>XNR<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Take the result of the Exclusive NOR logical operation made between Sa and Sb, and store it in D<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Logic Operation Instructions List<\/p>\n<ul>\n<li>Comparison Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u260517<\/p>\n<\/td>\n<td>\n<p>CMP<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Compare the data at Sa and data at Sb and store the result to FO0~FO2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>37<\/p>\n<\/td>\n<td>\n<p>ZNCMP<\/p>\n<\/td>\n<td>\n<p>S,SU,SL<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Compare S with the zones formed by the upper limit SU and lower limit SL, and store the result to FO0~FO2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>170<\/p>\n<\/td>\n<td>\n<p>\uff1d<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Equal to compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>171<\/p>\n<\/td>\n<td>\n<p>\uff1e<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Greater than compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>172<\/p>\n<\/td>\n<td>\n<p>\uff1c<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Less than compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>173<\/p>\n<\/td>\n<td>\n<p>\uff1c\uff1e<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Not equal to compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>174<\/p>\n<\/td>\n<td>\n<p>\uff1e\uff1d<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Greater than or equal to compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>175<\/p>\n<\/td>\n<td>\n<p>\uff1d\uff1c<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Less than or equal to compare<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Comparison Instructions List<\/p>\n<ul>\n<li>Data Movement Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605 8<\/p>\n<\/td>\n<td>\n<p>MOV<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Transfer data from S to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 9<\/p>\n<\/td>\n<td>\n<p>MOV\/<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Invert data S, and then transfers the result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>40<\/p>\n<\/td>\n<td>\n<p>BITRD<\/p>\n<\/td>\n<td>\n<p>S,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Read the status of the bits specified by N within S, and send it to FO0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>41<\/p>\n<\/td>\n<td>\n<p>BITWR<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Write the INB input status into the bits specified by N within D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>42<\/p>\n<\/td>\n<td>\n<p>BITMV<\/p>\n<\/td>\n<td>\n<p>S,Ns,D,Nd<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Write the status of bit specified by Ns within S into the bit specified by Nd within D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>43<\/p>\n<\/td>\n<td>\n<p>NBMV<\/p>\n<\/td>\n<td>\n<p>S,Ns,D,Nd<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Write the Ns nibble within S to the Nd nibble within D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>44<\/p>\n<\/td>\n<td>\n<p>BYMV<\/p>\n<\/td>\n<td>\n<p>S,Ns,D,Nd<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Write the byte specified by Ns within S to the byte specified by Nd within D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>45<\/p>\n<\/td>\n<td>\n<p>XCHG<\/p>\n<\/td>\n<td>\n<p>Da,Db<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Exchange the values of Da and Db<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>46<\/p>\n<\/td>\n<td>\n<p>SWAP<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Swap the high-byte and low-byte of D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>115<\/p>\n<\/td>\n<td>\n<p>DBUF<\/p>\n<\/td>\n<td>\n<p>ID,CH,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Store the data form Expansion Module to PLC register<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>160<\/p>\n<\/td>\n<td>\n<p>RWFR<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,Pr,L,Sa<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Read\/write file register commands<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>161<\/p>\n<\/td>\n<td>\n<p>WR-MP<\/p>\n<\/td>\n<td>\n<p>S,Bk,Os,Pr,L,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Write memory pack<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>162<\/p>\n<\/td>\n<td>\n<p>RD-MP<\/p>\n<\/td>\n<td>\n<p>Bk,Os,Pr,L,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Read memory pack<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Data Movement Instructions List<\/p>\n<ul>\n<li>Shifting\/Rotating Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605 6<\/p>\n<\/td>\n<td>\n<p>BSHF<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>shift left or right 1 bit of D register<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>51<\/p>\n<\/td>\n<td>\n<p>SHFL<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Shift left the D register N bits and move the last shifted out bits to FO0. The empty bits will be replaced by INB input bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>52<\/p>\n<\/td>\n<td>\n<p>SHFR<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Shift right the D register N bits and move the last shifted out bits to FO0. The empty bits will be replaced by INB input bit<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>53<\/p>\n<\/td>\n<td>\n<p>ROTL<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Rotate left the D operand N bits and move the last rotated out bits to FO0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>54<\/p>\n<\/td>\n<td>\n<p>ROTR<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Rotate right the D operand N bits and move the last rotated out bits to FO0<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Shifting\/Rotating Instructions List<\/p>\n<ul>\n<li>Code Conversion Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>20<\/p>\n<\/td>\n<td>\n<p>\u2192BCD<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Binary to BCD conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>21<\/p>\n<\/td>\n<td>\n<p>\u2192BIN<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>BCD to Binary conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>33<\/p>\n<\/td>\n<td>\n<p>LCNV<\/p>\n<\/td>\n<td>\n<p>Md,S,Ts,D,L<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Linear conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>34<\/p>\n<\/td>\n<td>\n<p>MLC<\/p>\n<\/td>\n<td>\n<p>Rs,SI,Tx,Ty,TI,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Multiple linear conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>55<\/p>\n<\/td>\n<td>\n<p>B\u2192G<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Binary code to gray code conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>56<\/p>\n<\/td>\n<td>\n<p>G\u2192B<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Gray code to binary code conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>57<\/p>\n<\/td>\n<td>\n<p>DECOD<\/p>\n<\/td>\n<td>\n<p>S,Ns,N1,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Liner decode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>58<\/p>\n<\/td>\n<td>\n<p>ENCOD<\/p>\n<\/td>\n<td>\n<p>S,Ns,N1,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Encode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>61<\/p>\n<\/td>\n<td>\n<p>\u2192SEC<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Convert the time data (hours, minutes, seconds) of the three successive registers starting from S into seconds data then store to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>62<\/p>\n<\/td>\n<td>\n<p>\u2192HMS<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Convert the seconds data of S into time data (hours, minutes, seconds) and store the data in the three successive registers starting from D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>63<\/p>\n<\/td>\n<td>\n<p>\u2192HEX<\/p>\n<\/td>\n<td>\n<p>S,N,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Hexadecimal string to data conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>64<\/p>\n<\/td>\n<td>\n<p>\u2192ASCII<\/p>\n<\/td>\n<td>\n<p>S,N,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Data to hexadecimal string conversion<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Code Conversion Instruction List<\/p>\n<ul>\n<li>Flow Control Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2605 0<\/p>\n<\/td>\n<td>\n<p>MC<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>The start of master control loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 1<\/p>\n<\/td>\n<td>\n<p>MCE<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>The end of master control loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 2<\/p>\n<\/td>\n<td>\n<p>SKP<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>The start of skip loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2605 3<\/p>\n<\/td>\n<td>\n<p>SKPE<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>The end of skip loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>END<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>End of Program<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>22<\/p>\n<\/td>\n<td>\n<p>BREAK<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Exit from FOR-NEXT loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>65<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>1\uff5e6 alphanumeric<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Define the label with 1~6 alphanumeric characters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>66<\/p>\n<\/td>\n<td>\n<p>JMP<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Jump to LBL label and continues the program execution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>67<\/p>\n<\/td>\n<td>\n<p>CALL<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Call the sub-program begin with LBL label<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>68<\/p>\n<\/td>\n<td>\n<p>RTS<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Return to the calling main program from sub-program<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>69<\/p>\n<\/td>\n<td>\n<p>RTI<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Return to interrupted main program from sub-program<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>70<\/p>\n<\/td>\n<td>\n<p>FOR<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Define the starting point of the FOR Loop and the loop count N<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>71<\/p>\n<\/td>\n<td>\n<p>NEXT<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Define the end of FOR loop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>165<\/p>\n<\/td>\n<td>\n<p>FLBL<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Define the label with 1~6 alphanumeric characters in FCM.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>166<\/p>\n<\/td>\n<td>\n<p>FJMP<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Jump to LBL label and continues the program execution in FCM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>199<\/p>\n<\/td>\n<td>\n<p>TXTDF<\/p>\n<\/td>\n<td>\n<p>LN<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Ladder Program blocking function<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Flow Control Instructions List<\/p>\n<ul>\n<li>PID Control <\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>PID<\/p>\n<\/td>\n<td>\n<p>Ts,SR,OR,PR,WR<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>General PID operation (Main Unit)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>38<\/p>\n<\/td>\n<td>\n<p>PID2<\/p>\n<\/td>\n<td>\n<p>ID,CH,SR,OR,PR,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>General PID operation (Expansion Module)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>99<\/p>\n<\/td>\n<td>\n<p>TPCTL2<\/p>\n<\/td>\n<td>\n<p>ID,CH,SR,PR,OR,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>PID for temperature control (Expansion Module)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>PID Control List<\/p>\n<ul>\n<li>I\/O Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>74<\/p>\n<\/td>\n<td>\n<p>IMDIO<\/p>\n<\/td>\n<td>\n<p>D,N<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Update the I\/O signal on the main unit immediately<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>83<\/p>\n<\/td>\n<td>\n<p>SPD<\/p>\n<\/td>\n<td>\n<p>S,TI,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed detection<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>I\/O Instructions List<\/p>\n<ul>\n<li>Cumulative Timer Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>87<\/p>\n<\/td>\n<td>\n<p>T.01S<\/p>\n<\/td>\n<td>\n<p>CV,PV<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Cumulative timer using 1mS as the time base<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>88<\/p>\n<\/td>\n<td>\n<p>T.1S<\/p>\n<\/td>\n<td>\n<p>CV,PV<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Cumulative timer using 10mS as the time base<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>89<\/p>\n<\/td>\n<td>\n<p>T1S<\/p>\n<\/td>\n<td>\n<p>CV,PV<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Cumulative timer using 100mS as the time base<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Cumulative Timer Instructions List<\/p>\n<ul>\n<li>Watch Dog Timer Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>90<\/p>\n<\/td>\n<td>\n<p>WDT<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Set the WDT timer time out time to N mS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>91<\/p>\n<\/td>\n<td>\n<p>RSWDT<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Reset the WDT timer to 0<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Watch Dog Timer Instructions List<\/p>\n<ul>\n<li>High Speed Counter \/ Timer Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>92<\/p>\n<\/td>\n<td>\n<p>HSCTR<\/p>\n<\/td>\n<td>\n<p>CN<\/p>\n<\/td>\n<td>\n<p>DP<\/p>\n<\/td>\n<td>\n<p>Read the current CV value of the hardware HSCs, HSC0\uff5eHSC3, or HST on SOC to the corresponding CV register in the PLC respectively<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>93<\/p>\n<\/td>\n<td>\n<p>HSCTW<\/p>\n<\/td>\n<td>\n<p>S,CN,D<\/p>\n<\/td>\n<td>\n<p>DP<\/p>\n<\/td>\n<td>\n<p>Write the CV or PV register of HSC0\uff5eHSC3 or HST in the PLC to CV or PV register of the hardware HSC or HST on SOC respectively<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>High Speed Counter \/ Timer Instructions List<\/p>\n<ul>\n<li>Ramp \/ Soak Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>98<\/p>\n<\/td>\n<td>\n<p>RAMP2<\/p>\n<\/td>\n<td>\n<p>Om,Ta Td,Rt Rc,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Tracking type ramp function for analog output<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Ramp \/ Soak Instructions List<\/p>\n<ul>\n<li>Communication Function Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>150<\/p>\n<\/td>\n<td>\n<p>M-Bus<\/p>\n<\/td>\n<td>\n<p>Pt,SR,WR<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Modbus protocol communication instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>151<\/p>\n<\/td>\n<td>\n<p>CLINK<\/p>\n<\/td>\n<td>\n<p>Pt,MD,SR,WR<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>FATEK\/Generic protocol communication instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>152<\/p>\n<\/td>\n<td>\n<p>NCR<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Active network communication<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>156<\/p>\n<\/td>\n<td>\n<p>CMCTL<\/p>\n<\/td>\n<td>\n<p>ID,Pt,Ts,MD,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Communication module instruction<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Communication Function Instructions List<\/p>\n<ul>\n<li>Table Manipulation Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>100<\/p>\n<\/td>\n<td>\n<p>R\u2192T<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Rs,Td,L,Pr<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Register to table data move<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>101<\/p>\n<\/td>\n<td>\n<p>T\u2192R<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ts,L,Pr,Rd<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table to register data move<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>102<\/p>\n<\/td>\n<td>\n<p>T\u2192T<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ts,Td,L,Pr<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table to table data move<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>103<\/p>\n<\/td>\n<td>\n<p>BT_M<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ts,Td,L<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Copy the entire contents of Ts to Td<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>105<\/p>\n<\/td>\n<td>\n<p>R-T_S<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Rs,Ts,L,Pr<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table data seek<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>106<\/p>\n<\/td>\n<td>\n<p>T-T_C<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Ta,Tb,L,Pr<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>107<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>T_FIL<\/p>\n<\/td>\n<td>\n<p>Rs,Td,L<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Fill the table Td with Rs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>108<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>T_SHF<\/p>\n<\/td>\n<td>\n<p>IW,Ts,Td,L,OW<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table shift<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>109<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>T_ROT<\/p>\n<\/td>\n<td>\n<p>Ts,Fd,L<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Table rotate<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>110<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>QUEUE<\/p>\n<\/td>\n<td>\n<p>IW,Qu,L,Pr,OW<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Data queue(FIFO)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>111<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>STACK<\/p>\n<\/td>\n<td>\n<p>IW,ST,L,Pr,OW<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Data stack(FILO)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>112<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>BKCMP<\/p>\n<\/td>\n<td>\n<p>Rs,Ts,L,D<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Block compare(CAM switch)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>113<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>SORT<\/p>\n<\/td>\n<td>\n<p>S,D,L<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Sorting the registers starting from S length L and store the sorted result to D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>114<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Z-WR<\/p>\n<\/td>\n<td>\n<p>N<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>P<\/p>\n<\/td>\n<td>\n<p>Zone set or clear<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Table Manipulation Instructions List<\/p>\n<ul>\n<li>Matrix Manipulation Instructions<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>120<\/p>\n<\/td>\n<td>\n<p>MAND<\/p>\n<\/td>\n<td>\n<p>Ma,Mb,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix AND<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>121<\/p>\n<\/td>\n<td>\n<p>MOR<\/p>\n<\/td>\n<td>\n<p>Ma,Mb,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix OR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>122<\/p>\n<\/td>\n<td>\n<p>MXOR<\/p>\n<\/td>\n<td>\n<p>Ma,Mb,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix exclusive OR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>123<\/p>\n<\/td>\n<td>\n<p>MXNR<\/p>\n<\/td>\n<td>\n<p>Ma,Mb,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix enclusive OR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>124<\/p>\n<\/td>\n<td>\n<p>MINV<\/p>\n<\/td>\n<td>\n<p>Ms,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix invert<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>126<\/p>\n<\/td>\n<td>\n<p>MBRD<\/p>\n<\/td>\n<td>\n<p>Ms,L,Pr<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix bit read<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>128<\/p>\n<\/td>\n<td>\n<p>MBSHF<\/p>\n<\/td>\n<td>\n<p>Ms,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix bit shift<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>129<\/p>\n<\/td>\n<td>\n<p>MBROT<\/p>\n<\/td>\n<td>\n<p>Ms,Md,L<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Matrix bit rotate<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>130<\/p>\n<\/td>\n<td>\n<p>MBCNT<\/p>\n<\/td>\n<td>\n<p>Ms,L,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Calculate the total number of bits that are 0 or 1 in Ms, then store the results into D<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Matrix Manipulation Instructions List<\/p>\n<ul>\n<li>NC Positioning Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>137<\/p>\n<\/td>\n<td>\n<p>ICA<\/p>\n<\/td>\n<td>\n<p>Ps,Is,Po,Ag<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Interrupt Constant Angle<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>138<\/p>\n<\/td>\n<td>\n<p>ICF<\/p>\n<\/td>\n<td>\n<p>Ps,Is,Po,Pd<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Interrupt Constant Feed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>139<\/p>\n<\/td>\n<td>\n<p>HSPWM<\/p>\n<\/td>\n<td>\n<p>Pw,Op,Rs,Pn,OR,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>High Speed PWM<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>140<\/p>\n<\/td>\n<td>\n<p>HSPSO<\/p>\n<\/td>\n<td>\n<p>Ps,SR,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>HSPSO instruction of NC positioning control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>141<\/p>\n<\/td>\n<td>\n<p>MPARA<\/p>\n<\/td>\n<td>\n<p>Ps,SR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Parameter setting instruction of NC positioning control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>142<\/p>\n<\/td>\n<td>\n<p>PSOFF<\/p>\n<\/td>\n<td>\n<p>Ps<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>NC pulse output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>143<\/p>\n<\/td>\n<td>\n<p>PSCNV<\/p>\n<\/td>\n<td>\n<p>Ps,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Position of pulse unit to engineering unit convert<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>144<\/p>\n<\/td>\n<td>\n<p>HSPWM2<\/p>\n<\/td>\n<td>\n<p>Pw,Op,Hz,OR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>High Speed PWM (Mode2)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>147<\/p>\n<\/td>\n<td>\n<p>MHSPO<\/p>\n<\/td>\n<td>\n<p>Gp,SR,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Multi-Axis high speed pulse output<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>148<\/p>\n<\/td>\n<td>\n<p>MPG<\/p>\n<\/td>\n<td>\n<p>Sc,Ps,Po,Mr,WR<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Manual Pulse<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NC Positioning Instruction List<\/p>\n<ul>\n<li>Interrupt Control Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>145<\/p>\n<\/td>\n<td>\n<p>EN<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Enable HSC, HST, external INT or peripheral operation<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>146<\/p>\n<\/td>\n<td>\n<p>DIS<\/p>\n<\/td>\n<td>\n<p>LBL<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Disable HSC, HST, external INT or peripheral operation<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Interrupt Control Instruction List<\/p>\n<ul>\n<li>Floating Point Number Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>200<\/p>\n<\/td>\n<td>\n<p>I\u2192F<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Conversion of integer to floating point munber<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>201<\/p>\n<\/td>\n<td>\n<p>F\u2192I<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>D P<\/p>\n<\/td>\n<td>\n<p>Conversion of floating point munberto integer<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>202<\/p>\n<\/td>\n<td>\n<p>FADD<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number addition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>203<\/p>\n<\/td>\n<td>\n<p>FSUB<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number subtraction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>204<\/p>\n<\/td>\n<td>\n<p>FMUL<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number multiplication<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>205<\/p>\n<\/td>\n<td>\n<p>FDIV<\/p>\n<\/td>\n<td>\n<p>Sa,Sb,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number divsion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>206<\/p>\n<\/td>\n<td>\n<p>FCMP<\/p>\n<\/td>\n<td>\n<p>Sa,Sb<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>207<\/p>\n<\/td>\n<td>\n<p>FZCP<\/p>\n<\/td>\n<td>\n<p>S,Su,Sl<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number zone compare<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>208<\/p>\n<\/td>\n<td>\n<p>FSQR<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number square root<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>209<\/p>\n<\/td>\n<td>\n<p>FSIN<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Sin trigonometric instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>210<\/p>\n<\/td>\n<td>\n<p>FCOS<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Cos trigonometric instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>211<\/p>\n<\/td>\n<td>\n<p>FTAN<\/p>\n<\/td>\n<td>\n<p>S,D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Tan trigonometric instruction<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>212<\/p>\n<\/td>\n<td>\n<p>FNEG<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Change sign of the floating point number<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>213<\/p>\n<\/td>\n<td>\n<p>FABS<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating point number absolute value<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>218<\/p>\n<\/td>\n<td>\n<p>FASIN<\/p>\n<\/td>\n<td>\n<p>S,D,MD<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating Point arc sine<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>219<\/p>\n<\/td>\n<td>\n<p>FACOS<\/p>\n<\/td>\n<td>\n<p>S,D,MD<\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>Floating Point arc cosine<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Floating Point Number Instruction<\/p>\n<ul>\n<li>Module Function Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>258<\/p>\n<\/td>\n<td>\n<p>MODCONF<\/p>\n<\/td>\n<td>\n<p>OP,ID,CH,SB<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Module configuration setting<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Module Function Instruction List<\/p>\n<ul>\n<li>Motion Basic Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>177<\/p>\n<\/td>\n<td>\n<p>MFSysStop<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Control motion system stop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>185<\/p>\n<\/td>\n<td>\n<p>MFSysRstAlm<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Reset motion alarm status<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>187<\/p>\n<\/td>\n<td>\n<p>MFSysInit<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Servo initialization<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>188<\/p>\n<\/td>\n<td>\n<p>MFSysRCPR<\/p>\n<\/td>\n<td>\n<p>Md,D,Gp<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Read motion recipe<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>189<\/p>\n<\/td>\n<td>\n<p>MFSysRCPW<\/p>\n<\/td>\n<td>\n<p>Md,D,Gp<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Write motion recipe<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>191<\/p>\n<\/td>\n<td>\n<p>MFSysCAMR<\/p>\n<\/td>\n<td>\n<p>Md,D,ID,L<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Motion CAM read<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>192<\/p>\n<\/td>\n<td>\n<p>MFSysCAMW<\/p>\n<\/td>\n<td>\n<p>Md,D,ID,L<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Motion CAM write<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>196<\/p>\n<\/td>\n<td>\n<p>MFSysCAMGen<\/p>\n<\/td>\n<td>\n<p>ID,Md,D,L<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Motion CAM Generation<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>235<\/p>\n<\/td>\n<td>\n<p>MFSysSetVirt<\/p>\n<\/td>\n<td>\n<p>AX<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Set real axis to virtual axis<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>236<\/p>\n<\/td>\n<td>\n<p>MFSDOR<\/p>\n<\/td>\n<td>\n<p>S,I,SI,LN,EC,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Read EtherCAT slave parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>237<\/p>\n<\/td>\n<td>\n<p>MFSDOW<\/p>\n<\/td>\n<td>\n<p>S,I,SI,LN,EC,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Write EtherCAT slave parameters<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Motion Basic Instruction list<\/p>\n<ul>\n<li>Motion Mode 1 Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>176<\/p>\n<\/td>\n<td>\n<p>MFFlowStart<\/p>\n<\/td>\n<td>\n<p>ID<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Start the motion flow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>181<\/p>\n<\/td>\n<td>\n<p>MFChgTbPrm<\/p>\n<\/td>\n<td>\n<p>Gp,ID,N,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Change motion parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>182<\/p>\n<\/td>\n<td>\n<p>MFFlowPause<\/p>\n<\/td>\n<td>\n<p>ID<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Pause the motion flow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>183<\/p>\n<\/td>\n<td>\n<p>MFFlowResume<\/p>\n<\/td>\n<td>\n<p>ID<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Resume the motion flow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>184<\/p>\n<\/td>\n<td>\n<p>MFFlowHalt<\/p>\n<\/td>\n<td>\n<p>ID<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Halt the motion flow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>186<\/p>\n<\/td>\n<td>\n<p>MFFlowStop<\/p>\n<\/td>\n<td>\n<p>ID<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Stop the motion flow<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>198<\/p>\n<\/td>\n<td>\n<p>MFMapTbPrm<\/p>\n<\/td>\n<td>\n<p>Gp,N,L<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Set Motion Parameter Mapping Data<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Motion Mode 1 list<\/p>\n<ul>\n<li>Motion Mode 2 Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>178<\/p>\n<\/td>\n<td>\n<p>MFHome<\/p>\n<\/td>\n<td>\n<p>AX<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Control the axis homing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>179<\/p>\n<\/td>\n<td>\n<p>MFPointMov<\/p>\n<\/td>\n<td>\n<p>PT<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Start point position control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>180<\/p>\n<\/td>\n<td>\n<p>MFJog<\/p>\n<\/td>\n<td>\n<p>AX,D,MD<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Control the axis homing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>181<\/p>\n<\/td>\n<td>\n<p>MFChgTbPrm<\/p>\n<\/td>\n<td>\n<p>Gp,ID,N,D<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Change motion parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>198<\/p>\n<\/td>\n<td>\n<p>MFMapTbPrm<\/p>\n<\/td>\n<td>\n<p>Gp,N,L<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Set Motion Parameter Mapping Data<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Motion Mode 2 Instruction list<\/p>\n<ul>\n<li>Motion Mode 3 Instruction<\/li>\n<\/ul>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>178<\/p>\n<\/td>\n<td>\n<p>MFHome<\/p>\n<\/td>\n<td>\n<p>AX<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Control the axis homing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>180<\/p>\n<\/td>\n<td>\n<p>MFJog<\/p>\n<\/td>\n<td>\n<p>AX,D,MD<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Control the axis homing<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>193<\/p>\n<\/td>\n<td>\n<p>MFGearMPG<\/p>\n<\/td>\n<td>\n<p>M,S,N,D,T<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Motion axis gear in<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>194<\/p>\n<\/td>\n<td>\n<p>MFVelCtl<\/p>\n<\/td>\n<td>\n<p>AX,V,MX<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Motion Velocity Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>195<\/p>\n<\/td>\n<td>\n<p>MFTorqCtl<\/p>\n<\/td>\n<td>\n<p>AX,T,MXf<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Motion Torque Control<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>197<\/p>\n<\/td>\n<td>\n<p>MFAxMov<\/p>\n<\/td>\n<td>\n<p>AX,MD,Ps,V,A,D,SA,SD,DR,BP<\/p>\n<\/td>\n<td>\n<p>D<\/p>\n<\/td>\n<td>\n<p>Motion Axis Movement<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>238<\/p>\n<\/td>\n<td>\n<p>MFAxLMov<\/p>\n<\/td>\n<td>\n<p>TAX,MD,DR,BF,D,EC<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Move axes along a linear path<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>239<\/p>\n<\/td>\n<td>\n<p>MFAxCirMov<\/p>\n<\/td>\n<td>\n<p>TAX,MD,DR,BF,D,EC<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Move axes along a circular path<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>240<\/p>\n<\/td>\n<td>\n<p>MFPathMov<\/p>\n<\/td>\n<td>\n<p>AX1,AX2,AX3,PT,V,TA,TD,SA,SD,EC<\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Motion Mode 3 Instruction list<\/p>\n","protected":false},"excerpt":{"rendered":"<p>3-1 Sequential Instructions Operand Symbol Function Ins [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[51],"tags":[],"class_list":["post-3269","post","type-post","status-publish","format-standard","hentry","category-en-mplc-m07"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3269"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3269\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}