{"id":3297,"date":"2026-11-17T18:40:47","date_gmt":"2026-11-17T10:40:47","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-02\/"},"modified":"2026-11-17T18:40:47","modified_gmt":"2026-11-17T10:40:47","slug":"sc3-sc3man-en-02","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-02\/","title":{"rendered":"Chapter 2 Selecting a SC3 Servo Driver"},"content":{"rendered":"<h3>2.1 Ratings and Specifications <\/h3>\n<p>2.1.1 Ratings <br \/>\u25a0 1-phase 220VAC \/ 3-phase 220VAC <br \/>\u25c6 SC303AAD\u25af\u25af \/ SC306AAF\u25af\u25af \/ SC308AAG\u25af\u25af \/ SC310AAH\u25af\u25af<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>Model <\/p>\n<\/td>\n<td>\n<p>03A <\/p>\n<\/td>\n<td>\n<p>06A <\/p>\n<\/td>\n<td>\n<p>08A <\/p>\n<\/td>\n<td>\n<p>10A <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Continuous Output Current [Amps] <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>10 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Instan. Max. Output Current [Amps] <\/p>\n<\/td>\n<td>\n<p>10 <\/p>\n<\/td>\n<td>\n<p>14 <\/p>\n<\/td>\n<td>\n<p>21 <\/p>\n<\/td>\n<td>\n<p>23 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Main Circuit <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Power Supply <\/p>\n<\/td>\n<td>\n<p>1-phase \/ 3-phase <br \/>AC 220V <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>3-phase AC 220V\uff0c-15% \uff5e +10%, 50 Hz \/ 60 Hz*1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Current [Amps] <\/p>\n<\/td>\n<td>\n<p>1.9 <\/p>\n<\/td>\n<td>\n<p>3.9 <\/p>\n<\/td>\n<td>\n<p>5.4 <\/p>\n<\/td>\n<td>\n<p>6.3 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Control Power Supply <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>1-phase AC 220V\uff0c-15% \uff5e +10%, 50 Hz \/ 60 Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Power Supply Capacity [kVA] <\/p>\n<\/td>\n<td>\n<p>1.3 <\/p>\n<\/td>\n<td>\n<p>1.7 <\/p>\n<\/td>\n<td>\n<p>2.4 <\/p>\n<\/td>\n<td>\n<p>2.8 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Regenertative Resistor <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Bulit-in <br \/>Regenertative Resistor <\/p>\n<\/td>\n<td>\n<p>Resistance [\u03a9] <\/p>\n<\/td>\n<td>\n<p>-*2<\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Capacity [W] <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>80 <\/p>\n<\/td>\n<td>\n<p>80 <\/p>\n<\/td>\n<td>\n<p>80 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Min. Allowable External Resistance [\u03a9] <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>15 <\/p>\n<\/td>\n<td>\n<p>12 <\/p>\n<\/td>\n<td>\n<p>12 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Overvoltage Category <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u2162 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*1: If use 1-phase AC220V for power supply, the current output may not meet the spec. *2: 03A servo driver have no bulit-in regenerative resistor. <\/p>\n<p>\u25a0 3-phase380VAC <br \/>\u25c6 SC303ADE\u25af\u25af \/ SC306ADH\u25af\u25af \/ SC310ADI\u25af\u25af \/ SC315ADK\u25af\u25af \/ SC328ABL\u25af\u25af<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"4\">\n<p>Model <\/p>\n<\/td>\n<td>\n<p>03A <\/p>\n<\/td>\n<td>\n<p>06 <\/p>\n<\/td>\n<td>\n<p>10A <\/p>\n<\/td>\n<td>\n<p>15A <\/p>\n<\/td>\n<td>\n<p>28A <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>Continuous Output Current [Amps] <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>10 <\/p>\n<\/td>\n<td>\n<p>15 <\/p>\n<\/td>\n<td>\n<p>28 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>Instan. Max. Output Current [Amps] <\/p>\n<\/td>\n<td>\n<p>8.5 <\/p>\n<\/td>\n<td>\n<p>14 <\/p>\n<\/td>\n<td>\n<p>45 <\/p>\n<\/td>\n<td>\n<p>45 <\/p>\n<\/td>\n<td>\n<p>63 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Main Circuit <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Power Supply <\/p>\n<\/td>\n<td colspan=\"5\">\n<p>3-phase AC 380V\uff0c-15% \uff5e +10%, <br \/>50 Hz \/ 60 Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Current [Amps] <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>5.9 <\/p>\n<\/td>\n<td>\n<p>9.7 <\/p>\n<\/td>\n<td>\n<p>15.5 <\/p>\n<\/td>\n<td>\n<p>24.8 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>Control Power Supply <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>DC 24V\uff0c-10% \uff5e +10%, 50W <\/p>\n<\/td>\n<td>\n<p>1-phase AC 380V\uff0c-15% \uff5e+10%, <br \/>50 Hz \/ 60 Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>Power Supply Capacity [kVA] <\/p>\n<\/td>\n<td>\n<p>2.0 <\/p>\n<\/td>\n<td>\n<p>3.9 <\/p>\n<\/td>\n<td>\n<p>7.8 <\/p>\n<\/td>\n<td>\n<p>12.4 <\/p>\n<\/td>\n<td>\n<p>19.8 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Regenertative Resistor <\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Bulit-in <br \/>Regenertative Resistor <\/p>\n<\/td>\n<td>\n<p>Resistance [\u03a9] <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<td>\n<p>-*1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Capacity [W]<\/p>\n<\/td>\n<td>\n<p>80 <\/p>\n<\/td>\n<td>\n<p>80 <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>150 <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Min. Allowable External Resistance [\u03a9] <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>20 <\/p>\n<\/td>\n<td>\n<p>15 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>Overvoltage Category <\/p>\n<\/td>\n<td colspan=\"5\">\n<p>\u2162 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*1: 28A servo driver have no bulit-in regenerative resistor. <\/p>\n<h4>2.1.2 Specifications <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Specification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Control Method <\/p>\n<\/td>\n<td>\n<p>Position mode\u3001JOG mode\u3001speed mode\u2026etc <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Feedback<\/p>\n<\/td>\n<td>\n<p>Serial encoder\uff1a17bits or 23bits\uff08incremental encoder \/ absolute encoder\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Environment Conditions <\/p>\n<\/td>\n<td>\n<p>Operation Temp. <\/p>\n<\/td>\n<td>\n<p>0~+50\u2103 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage Temp.<\/p>\n<\/td>\n<td>\n<p>-20~+85\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Environment Humidity <\/p>\n<\/td>\n<td>\n<p>90% relative humidity max. (with no freezing or condensation) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Storage Humidity<\/p>\n<\/td>\n<td>\n<p>90% relative humidity max. (with no freezing or condensation)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Resistance <\/p>\n<\/td>\n<td>\n<p>4.9m\/s2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shock Resistance<\/p>\n<\/td>\n<td>\n<p>19.6m\/s2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Mounting <\/p>\n<\/td>\n<td>\n<p>Base-mounted <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Performance <\/p>\n<\/td>\n<td>\n<p>Speed Control Range <\/p>\n<\/td>\n<td>\n<p>1:10000\uff08At the rated torque, the lower limit of the speed control range must not cause the Servomotor to stop.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Response Freq.<\/p>\n<\/td>\n<td>\n<p>3.1KHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Coefficient of Speed Flucuation <\/p>\n<\/td>\n<td>\n<p>\u00b10.01% of rated speed max. (for a load fluctuation of 0% to 100%)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0% of rated speed max. (for a voltage fluctuation of \u00b110%)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u00b10.1% of rated speed max. (for a temperature fluctuation of 25\u00b0C\u00b125\u00b0C)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Speed Control <\/p>\n<\/td>\n<td>\n<p>Reference Voltage<\/p>\n<\/td>\n<td>\n<p>DC\u00b110V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Impedance<\/p>\n<\/td>\n<td>\n<p>Approx. 20K\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Circuit Time Constant<\/p>\n<\/td>\n<td>\n<p>47us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Torque Control <\/p>\n<\/td>\n<td>\n<p>Reference Voltage<\/p>\n<\/td>\n<td>\n<p>DC\u00b110V<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Impedance<\/p>\n<\/td>\n<td>\n<p>Approx. 20K\u03a9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Circuit Time Constant<\/p>\n<\/td>\n<td>\n<p>47us<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Digital Input <\/p>\n<\/td>\n<td>\n<p>Number of points<\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Signals That Can Be Allocated <\/p>\n<\/td>\n<td>\n<p>Servo ON\uff08\/S-ON\uff09*1\u3001Proportional Control\uff08\/P-CON\uff09*1\u3001Forward Drive Prohibit\uff08P-OT\uff09\u3001Reverse Drive Prohibit\uff08N-OT\uff09\u3001Alarm Reset\uff08\/ALM-RST\uff09\u3001Forward External Torque Limit\uff08\/P-CL\uff09\u3001Reverse External Torque Limit\uff08\/N-CL\uff09\u3001Position Deviation Clear\uff08\/CLR\uff09\u3001Internal Setup Speed Switch\u2026etc <br \/>A Signal can be allocated and positive and negative logic can be changed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Digital Output <\/p>\n<\/td>\n<td>\n<p>Number of points<\/p>\n<\/td>\n<td>\n<p>6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output Signals That Can Be Allocated <\/p>\n<\/td>\n<td>\n<p>Servo Alarm\uff08ALM\uff09\u3001Position Completion\uff08\/COIN\uff09\u3001Speed Coincidence Detection\uff08\/V-CMP\uff09\u3001Rotation Detection\uff08\/TGON\uff09\u3001Servo Ready\uff08\/S-RDY\uff09\u3001Torque Limit Detection\uff08\/CLT\uff09\u3001Brake\uff08\/BK\uff09\u3001Encoder Origin Output\uff08PGC\uff09 A Signal can be allocated and positive and negative logic can be changed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Encoder Divided Pulse Output <\/p>\n<\/td>\n<td>\n<p>Phase A, phase B, phase Z: Line-driver output <br \/>Number of divided output pulses: Any setting is allowed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>RS-485 *\uff11<br \/>Communication <\/p>\n<\/td>\n<td>\n<p>Protocal<\/p>\n<\/td>\n<td>\n<p>MODBUS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1:N Communications <\/p>\n<\/td>\n<td>\n<p>Up to N=127 stations <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Axis Address Setting<\/p>\n<\/td>\n<td>\n<p>Set with parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>EtherCAT <br \/>Communication <\/p>\n<\/td>\n<td>\n<p>Protocal <\/p>\n<\/td>\n<td>\n<p>CoE (CANOpen over EtherCAT) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control Mode<\/p>\n<\/td>\n<td>\n<p>csp, pp, hm, csv, cst, pv, tq<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Homing Method <\/p>\n<\/td>\n<td>\n<p>1-14, 17-30, 33, 34, 35, 37 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Synchronization Mode<\/p>\n<\/td>\n<td>\n<p>DC, SM2, FreeRun<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cycle Time <\/p>\n<\/td>\n<td>\n<p>125us <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Displays\/Indicators<\/p>\n<\/td>\n<td>\n<p>CHARGE indicator and five-digit seven-digit display<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Regenerative Processing <\/p>\n<\/td>\n<td>\n<p>Built-in (An external resistor must be connected to 220V_03A &amp; 380V_28A) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Overtravel\uff08OT\uff09Prevention <\/p>\n<\/td>\n<td>\n<p>Stopping with dynamic brake (DB), deceleration to a stop, or coasting to a stop for the P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Prohibit) signal <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Protective Function<\/p>\n<\/td>\n<td>\n<p>Overcurrent, overvoltage, low voltage, overload, regeneration error, etc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Monitoring Functions <\/p>\n<\/td>\n<td>\n<p>Speed, Current position, Reference pulse count (accumulated), Position deviation, Motor current, Operating status, Input\/output signals<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Utility Functions <\/p>\n<\/td>\n<td>\n<p>Gain adjustment, alarm history, jogging, origin search, etc. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Intelligent Functions<\/p>\n<\/td>\n<td>\n<p>Bulit-in Auto-tuning function<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Applicable Load Inertia <\/p>\n<\/td>\n<td>\n<p>Less than 5 times the motor inertia <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Position <\/p>\n<\/td>\n<td>\n<p>Feedforward Compensation<\/p>\n<\/td>\n<td>\n<p>0\uff5e100%\uff08Setup Unit1%\uff09 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reference Pulse Form <\/p>\n<\/td>\n<td>\n<p>One of the following is selected: <br \/>Pulse+Direction \uff08P\/R\uff09pulse trains, CW+CCW\uff08U\/D\uff09pulse trains, and two-phase pulse trains with 90 degree phase differential <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Input Form<\/p>\n<\/td>\n<td>\n<p>Line driver or open-collector<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Max. Input Frequency <\/p>\n<\/td>\n<td>\n<p>\u2022Line Driver <br \/>Pulse+Direction \uff08P\/R\uff09pulse trains, CW+CCW\uff08U\/D\uff09pulse trains: 500K pps two-phase pulse trains with 90-degree phase differential: 500K pps <br \/>\u2022Open-Collector <br \/>P Pulse+Direction \uff08P\/R\uff09pulse trains, CW+CCW\uff08U\/D\uff09pulse trains: 200K pps two-phase pulse trains with 90-degree phase differential: 200K pps <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*\uff11: Only support pulse type model<\/p>\n<h3>2.2 SC3 External Dimensions<\/h3>\n<p>\u25c6 220V: SC303AAD\u25af\u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-02\/sc3-sc3man-en-02-001.png\" \/><\/p>\n<p>\u25c6 220V: SC306AAF\u25af\u25af<br \/>380V: SC303ADE\u25af\u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-02\/sc3-sc3man-en-02-002.png\" \/><\/p>\n<p>\u25c6  220V: SC308AAG\u25af\u25af \/ SC310AAH\u25af\u25af<br \/>\t 380V: SC306ADH\u25af\u25af \/ SC310ADI\u25af\u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-02\/sc3-sc3man-en-02-003.png\" \/><\/p>\n<p>\u25c6 380V: SC315ADK\u25af\u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-02\/sc3-sc3man-en-02-004.png\" \/><\/p>\n<p>\u25c6 380V: SC328ABL\u25af\u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-02\/sc3-sc3man-en-02-005.png\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>2.1 Ratings and Specifications 2.1.1 Ratings \u25a0 1-phase  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3297","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3297"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3297\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3297"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3297"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}