{"id":3299,"date":"2026-11-17T18:40:53","date_gmt":"2026-11-17T10:40:53","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-04\/"},"modified":"2026-11-17T18:40:53","modified_gmt":"2026-11-17T10:40:53","slug":"sc3-sc3man-en-04","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-04\/","title":{"rendered":"Chapter 4 Wiring and Connecting Servo driver"},"content":{"rendered":"<h3>4.1 Precautions related to wiring <\/h3>\n<h4>4.1.1 General Precautions <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-001.png\" \/>DANGER <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Do not change any wiring while power is being supplied. <br \/>There is a risk of electric shock or injury. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-002.png\" \/>WARNING <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Wiring and inspections must be performed only by qualified engineers. <\/p>\n<p>There is a risk of electric shock or product failure. <\/p>\n<p>\u25cf Check all wiring and power supplies carefully. <\/p>\n<p>Incorrect wiring or incorrect voltage application to the output circuits may cause short-circuit failures. If a short-circuit failure occurs as a result of any of these causes, the holding brake will not work. This could damage the machine or cause an accident that may result in death or injury. <\/p>\n<p>\u25cf Connect the AC and DC power supplies to the specified servo driver terminals. <\/p>\n<p>\u2022 Connect an AC power supply to the L1, L2, and L3 terminals and the L1C and L2C terminals on the servo driver. <\/p>\n<p>\u2022 Connect a DC power supply to the B1\/ and 2 terminals and the L1C and L2C terminals on the servo driver. <\/p>\n<p>\u2022 There is a risk of failure or fire. <\/p>\n<p>\u25cf If you use a servo driver with the Dynamic Brake Hardware Option, connect an External Dynamic Brake Resistor that is suitable for the machine and equipment specifications to the specified terminals. <\/p>\n<p>There is a risk of unexpected operation, machine damage, burning, or injury when an emer- gency stop is performed. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-003.png\" \/>CAUTION <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Wait for at least five minutes after turning OFF the power supply and then make sure that the CHARGE indicator is not lit before starting wiring or inspection work. Do not touch the power supply terminals while the CHARGE lamp is lit because high voltage may still remain in the servo driver even after turning OFF the power supply. <\/p>\n<p>There is a risk of electric shock. <\/p>\n<p>\u25cf Observe the precautions and instructions for wiring and trial operation precisely as described in this document. <\/p>\n<p>Failures caused by incorrect wiring or incorrect voltage application in the brake circuit may cause the servo driver to fail, damage the equipment, or cause an accident resulting in death or injury. <\/p>\n<p>\u25cf Check the wiring to be sure it has been performed correctly. <\/p>\n<p>Connectors and pin layouts are sometimes different for different models. Always confirm the pin layouts in technical documents for your model before operation. <\/p>\n<p>There is a risk of failure or malfunction. <\/p>\n<p>\u25cf Connect wires to power supply terminals and motor connection terminals securely with the specified methods and tightening torque. <\/p>\n<p>Insufficient tightening may cause wires and terminal blocks to generate heat due to faulty con- tact, possibly resulting in fire. <\/p>\n<p>\u25cf Use shielded twisted-pair cables or screened unshielded multi-twisted-pair cables for I\/O Signal Cables and Encoder Cables. <\/p>\n<p>\u25cf Observe the following precautions when wiring the servo driver\u2019s main circuit terminals. \u2022 Turn ON the power supply to the servo driver only after all wiring, including the main circuit ter- minals, has been completed. <\/p>\n<p>\u2022 If a connector is used for the main circuit terminals, remove the main circuit connector from the servo driver before you wire it. <\/p>\n<p>\u2022 Insert only one wire per insertion hole in the main circuit terminals. <\/p>\n<p>\u2022 When you insert a wire, make sure that the conductor wire (e.g., whiskers) does not come into contact with adjacent wires. <\/p>\n<p>\u25cf Install molded-case circuit breakers and other safety measures to provide protection against short circuits in external wiring. <\/p>\n<p>There is a risk of fire or failure. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-004.png\" \/>NOTICE <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Whenever possible, use the Cables specified by Fatek. <\/p>\n<p>If you use any other cables, confirm the rated current and application environment of your model and use the wiring materials specified by Fatek or equivalent materials. <\/p>\n<p>\u25cf Securely tighten cable connector screws and lock mechanisms. <\/p>\n<p>Insufficient tightening may result in cable connectors falling off during operation. <\/p>\n<p>\u25cf Do not bundle power lines (e.g., the Main Circuit Cable) and low-current lines (e.g., the I\/O Signal Cables or Encoder Cables) together or run them through the same duct. If you do not place power lines and low-current lines in separate ducts, separate them by at least 30 cm. If the cables are too close to each other, malfunctions may occur due to noise affecting the low- current lines. <\/p>\n<p>\u25cf Install a battery at either the host controller or on the Encoder Cable. <\/p>\n<p>If you install batteries both at the host controller and on the Encoder Cable at the same time, you will create a loop circuit between the batteries, resulting in a risk of damage or burning. \u25cf When connecting a battery, connect the polarity correctly. <\/p>\n<p>There is a risk of battery rupture or encoder failure. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-005.png\" \/>Important <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Use a molded-case circuit breaker or fuse to protect the main circuit. The servo driver con- nects directly to a commercial power supply; it is not isolated through a transformer or other device. Always use a molded-case circuit breaker or fuse to protect the servo system from accidents involving different power system voltages or other accidents. <\/p>\n<p>\u25cf Install an earth leakage breaker. The servo driver does not have a built-in ground fault protec- tive circuit. To configure a safer system, install a ground fault detector against overloads and short-circuiting, or install a ground fault detector combined with a molded-case circuit breaker. \u25cf Do not turn the power supply ON and OFF more than necessary. <\/p>\n<p>\u2022 Do not use the servo driver for applications that require the power supply to turn ON and OFF frequently. Such applications will cause elements in the servo driver to deteriorate. <\/p>\n<p>\u2022 After you have started actual operation, allow at least one hour between turning the power supply ON and OFF (as a guideline). <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>To ensure safe, stable application of the servo system, observe the following precautions when wiring. <\/p>\n<p>\u2022 Use the cables specified by Fatek. Design and arrange the system so that each cable is as short as possible.\u2022 The signal cable conductors are as thin as 0.3 mm2. Do not subject them to excessive bending stress or tension.<\/p>\n<h4>4.1.2 Countermeasures against Noise <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-006.png\" \/><\/p>\n<\/td>\n<td>\n<p>The servo driver is designed as an industrial device. It therefore provides no measures to prevent radio interference. The servo driver uses high-speed switching elements in the main circuit. <br \/>Therefore, peripheral devices may be affected by switching noise. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>If the equipment is to be used near private houses or if radio interference is a problem, take <\/p>\n<p>countermeasures against noise.\u3002<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The servo driver uses microprocessors. Therefore, it may be affected by switching noise from peripheral devices. To prevent the noise from the servo driver or the peripheral devices from causing malfunctions of any devices, take the following countermeasures against noise as required. <\/p>\n<p>\u25cf Install the input reference device and Noise Filter as close to the servo driver as possible. <\/p>\n<p>\u25cf Always install a Surge Absorber for relays, solenoids, and Magnetic Contactor coils. <\/p>\n<p>\u25cf Do not place the following cables in the same duct or bundle them together. Also, separate the cables from each other  by at least 30 cm. <\/p>\n<p>\t\u2022 Main Circuit Cables and I\/O Signal Cables <br \/>\t\u2022 Main Circuit Cables and Encoder Cables <br \/>\u25cf Do not share the power supply with an electric welder or electrical discharge machine. If the servo driver is placed near \ta high-frequency generator, install Noise Filters on the input side on the Main Circuit Power Supply Cable and Control \tPower Supply Cable even if the same power supply is not shared with the high-frequency generator. Refer to the \tfollowing section for information on connecting Noise Filters. <\/p>\n<p>\u25cf Implement suitable grounding measures. Refer to the following section for information on grounding measures. <\/p>\n<p>Noise Filters<\/p>\n<p>You must attach Noise Filters in appropriate places to protect the servo driver from the adverse effects of noise. The following is an example of wiring for countermeasures against noise. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-007.jpg\" \/><\/p>\n<p>*1. For the ground wire, use a wire with a thickness of at least 2.0 mm2 (preferably, flat braided copper wire). <\/p>\n<p>*2. Whenever possible, use twisted-pair wires to wire all connections marked with<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-008.png\" \/><\/p>\n<p>Noise Filter Wiring and Connection Precautions <br \/>Always observe the following precautions when wiring or connecting Noise Filters.<\/p>\n<p>\u2022 Separate input lines from output lines. Do not place input lines and output lines in the same duct or bundle them <\/p>\n<p>together. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-009.jpg\" \/><\/p>\n<p>\u2022 Separate the Noise Filter ground wire from the output lines. Do not place the Noise Filter ground wire, output lines, and <\/p>\n<p>other signal lines in the same duct or bundle them together. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-010.jpg\" \/><\/p>\n<p>\u2022 Connect the Noise Filter ground wire directly to the grounding plate. Do not connect the Noise Filter ground wire to other ground wires. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-011.png\" \/><\/p>\n<p>\u2022If a Noise Filter is located inside a control panel, first connect the Noise Filter ground wire and the ground wires from \tother devices inside the control panel to the grounding plate for the control panel, then ground the plate. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-012.png\" \/><\/p>\n<h4>4.1.3 Grounding <\/h4>\n<p>Implement grounding measures as described in this section. Implementing suitable grounding measures will also help prevent malfunctions, which can be caused by noise. <\/p>\n<p>Observe the following precautions when wiring the ground cable. <\/p>\n<p>\u2022 Ground the servo driver to a resistance of 100 \u03a9 or less. <\/p>\n<p>\u2022 Be sure to ground at one point only. <\/p>\n<p>\u2022 Ground the Servomotor directly if the Servomotor is insulated from the machine. <\/p>\n<p>Motor Frame Ground or Motor Ground <\/p>\n<p>If you ground the Servomotor through the machine, switching noise current can flow from the main circuit of the servo <\/p>\n<p>driver through the stray capacitance of the Servomotor.To prevent this, always connect the FG terminal of the <\/p>\n<p>Servomotor Main Circuit Cable connected to the Servomotor to the ground terminal on the servo driver. Also be sure to <\/p>\n<p>ground the ground terminal. Always connect the shield wire of the Encoder Cable connected to the Servomotor to the <\/p>\n<p>connector case (shell). <\/p>\n<p>Ground both the Moving Coil and Magnetic Way of a Linear Servomotor <\/p>\n<p>Noise on I\/O Signal Cables <br \/>If noise enters the I\/O Signal Cable, connect the shield of the I\/O Signal Cable to the connector shell to ground it. If the Servomotor Main Circuit Cable is placed in a metal conduit, ground the conduit and its junction box. For all grounding, ground at one point only. <\/p>\n<h3>4.2 Basic Wiring Diagrams <\/h3>\n<p>\u2022 Input 3-phase AC380V <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-013.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-014.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-015.png\" \/><\/p>\n<p>\u2022Input 1-phase AC220V<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-016.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-017.png\" \/><\/p>\n<h3>4.3 Wiring the Power Supply to the servo driver <\/h3>\n<p>4.3.1 Terminal Symbols and Terminal Names <br \/>Use the main circuit connector on the servo driver to wire the main circuit power supply and control circuit power supply to the servo driver. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-018.png\" \/>CAUTION <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Wire all connections correctly according to the following table and specified reference information. There is a risk of servo driver failure or fire if incorrect wiring is performed. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The Servo driver have the following four types of main circuit power supply input specifica-tions. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25a0<\/p>\n<\/td>\n<td>\n<p>1-phase\/3-phaseAC220VPower Supply Input <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Terminal Symbols <\/p>\n<\/td>\n<td>\n<p>Terminal Name <\/p>\n<\/td>\n<td>\n<p>Specifications and Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>L1\uff0cL2\uff0cL3 <\/p>\n<\/td>\n<td>\n<p>Main circuit power <br \/>supply input terminals for AC power supply input <\/p>\n<\/td>\n<td>\n<p>3-phaseAC 200V\uff5e240V\uff0c-15%\uff5e+10%\uff0c50\/60Hz 1-phaseAC 200V\uff5e240V\uff0c-15%\uff5e+10%\uff0c50\/60Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>L1C\u3001L2C <\/p>\n<\/td>\n<td>\n<p>Control power supply terminals <\/p>\n<\/td>\n<td>\n<p>1-phaseAC 200V\uff5e240V\uff0c-15%\uff5e+10%\uff0c50\/60Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>B1\/\u2295\u3001B2\u3001B3<\/p>\n<\/td>\n<td>\n<p>Regenerative Resistor terminals <\/p>\n<\/td>\n<td>\n<p>If the regenerative capacity is insufficient, connect an External Regenerative Resistor between B1\/ and B2. <\/p>\n<p>The External Regenerative Resistor is not included. Obtain it separately. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2296<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>None. (Do not connect anything to this terminal.) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25a0\t3-phaseAC380V Power Supply input <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Terminal Symbols<\/p>\n<\/td>\n<td>\n<p>Terminal Name <\/p>\n<\/td>\n<td>\n<p>Specifications and Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>L1\uff0cL2\uff0cL3 <\/p>\n<\/td>\n<td>\n<p>Main circuit power supply input <br \/>terminals for AC <br \/>power supply <br \/>input <\/p>\n<\/td>\n<td>\n<p>3-phaseAC 380V\uff5e420V\uff0c-15%\uff5e+10%\uff0c50\/60Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>L1C\u3001L2C <\/p>\n<\/td>\n<td>\n<p>Control power <br \/>supply terminals <\/p>\n<\/td>\n<td>\n<p>03\/06\/10\/15A: DC 24V \uff0c-10%\uff5e+10%\uff0c50W <br \/>28A: 1-phaseAC 380V\uff5e420V\uff0c-15%\uff5e+10%\uff0c50\/60Hz <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>B1\/\u2295\u3001B2\u3001B3<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Regenerative <br \/>Resistor terminals <\/p>\n<\/td>\n<td>\n<p>03A\/06A\/10A\/15A <br \/>When the regenerative capacity is insufficient, remove the jumper wire between B2 and B3, and connect an external regenerative resistor between B1\/\u2295 and B2. Please purchase the external regenerative resistor separately. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>28A <br \/>It does not have build-in re-generative resistor, thereforce short wire between B2 and B3 is not allowed, and connect an external regenerative resistor between B1\/\u2295 and B2. Please purchase the external regenerative resistor separately. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2296<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>None. (Do not connect anything to this terminal.) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.3.2 Wiring Procedure for Main Circuit Connector<\/h4>\n<p>\u2022 Required Items <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Required Item <\/p>\n<\/td>\n<td>\n<p>Remarks <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Spring Opener or Flatblade <br \/>Screwdriver <\/p>\n<\/td>\n<td>\n<p>\u25cfSpring Opener servo driver accessory<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Flat-blade screwdriver <br \/>Commercially available screwdriver with tip width of 3.0 mm to 3.5 mm<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>1.Remove the main circuit connector and motor connector from the servo driver. 2.Remove the sheath from the wire to connect. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-019.png\" \/><\/p>\n<p>3\uff0eOpen the wire insertion hole on the terminal connector with the tool. There are the following two ways to open the insertion hole. Use either method. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-020.png\" \/><\/p>\n<p>4.Insert the conductor into the wire insertion hole. Then, remove the Spring Opener or flat-blade screwdriver. 5.Make all other connections in the same way. <\/p>\n<p>6.When you have completed wiring, attach the connectors to the servo driver. <\/p>\n<h4>4.3.3 Power ON Sequence<\/h4>\n<p>Consider the following points when you design the power ON sequence. <\/p>\n<p>\u25cf The ALM (Servo Alarm) signal is output for up to five seconds when the control power supply is turned ON. Take this into consideration when you design the power ON sequence, and turn ON the main circuit power supply to the servo driver when the ALM signal is OFF (alarm cleared). <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-021.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-022.png\" \/>WARNING <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cfEven after you turn OFF the power supply, a high residual voltage may still remain in the servo driver. To prevent electric shock, do not touch the power supply terminals after you turn OFF the power. When the voltage is discharged, the CHARGE indicator will turn OFF. Make sure the CHARGE indicator is OFF before you start wiring or inspection work. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-023.png\" \/>Important <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Turn ON the control power supply before the main circuit power supply or turn ON the control power supply and the main circuit power supply at the same time.Turn OFF the main circuit power supply first, and then turn OFF the control power supply. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.3.4 Power Supply Wiring Diagrams \t\u25cfWiring Example for Three-Phase Power Supply Input <\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-024.png\" \/><\/p>\n<p>*You do not have to connect B2 and B3 for the following models: 03A and 28A, Do not connect them. <\/p>\n<p>* AC380V 03A\/06A\/10A\/15A use DC +24V for control power supply <\/p>\n<p>4.3.5 Wiring Regenerative Resistors <br \/>\tThis section describes how to connect External Regenerative Resistors. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-025.png\" \/>WARNING <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf Be sure to wire Regenerative Resistors correctly. Do not connect B1\/\u2295 and B2. Doing so may result in fire or damage to the Regenerative Resistor or servo driver. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Connecting Regenerative Resistors <br \/>1.Remove the lead from between the B2 and B3 terminals on the servo driver. <\/p>\n<p>2.Connect the External Regenerative Resistor between the B1\/\u2295 and B2 terminals. <\/p>\n<p>3.Set Pn600 (Regenerative Resistor Capacity) and Pn603 (Regenerative Resistance). <\/p>\n<p>NOTE: 03A and 28A does not have build-in re-generative resistor, thereforce short wire between B2 and B3 is not <\/p>\n<p>allowed, and connect an external regenerative resistor between B1\/\u2295 and B2.<\/p>\n<h3>4.4 Wiring Servomotors <\/h3>\n<p>4.4.1 Terminal Symbols and Terminal Names <br \/>The servo driver terminals or connectors that are required to connect the servo driver to a Servomotor are given below. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Terminal\/Connector Symbols <\/p>\n<\/td>\n<td>\n<p>Terminal\/Connector Name <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>U\uff0cV\uff0cW <\/p>\n<\/td>\n<td>\n<p>Servomotor terminals <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-026.png\" \/><\/p>\n<\/td>\n<td>\n<p>Ground terminal <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CN2 <\/p>\n<\/td>\n<td>\n<p>Encoder connector <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.4.2 Pin Arrangement of Encoder Connector (CN2) <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Pin No. <\/p>\n<\/td>\n<td>\n<p>Signal <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>PG5V <\/p>\n<\/td>\n<td>\n<p>Encoder power supply +5 V <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>PG0V <\/p>\n<\/td>\n<td>\n<p>Encoder power supply 0 V <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>E+*<\/p>\n<\/td>\n<td>\n<p>Battery for absolute encoder (+) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>E-*<\/p>\n<\/td>\n<td>\n<p>Battery for absolute encoder (-) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>SD+ <\/p>\n<\/td>\n<td>\n<p>Serial data (+) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>SD- <\/p>\n<\/td>\n<td>\n<p>Serial data (-) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Shell <\/p>\n<\/td>\n<td>\n<p>Shield <\/p>\n<\/td>\n<td>\n<p>\u2014 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*No wiring is required for an incremental encoder. <\/p>\n<p>4.4.3 Wiring the servo driver to the Encoder <br \/>When Using an Absolute Encoder If you use an absolute encoder, use an Encoder Cable with a JUSP-BA01-E Battery Case or install a battery on the host controller. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-027.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-028.png\" \/><\/p>\n<p>\u2022 Wiring Example When Using an Encoder Cable with a Battery Case <\/p>\n<h4>4.4.4 Wiring the servo driver to the Holding Brake <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-029.png\" \/><\/p>\n<\/td>\n<td>\n<p>\u2022 If you use a Rotary Servomotor, select a Surge Absorber according to the brake current and brake power  supply. Refer to the following manual for details. <\/p>\n<p>\u2022 After the Surge Absorber is connected, check the brake operation delay time in your application. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> The Surge Absorber may affect the brake operation delay time. <\/p>\n<p>Configure the relay circuit to activate the holding brake for an emergency stop.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-030.png\" \/><\/p>\n<p>\u2022 The \/BK (Brake) signal cannot be used with the default settings. You must allocate the output signal. Refer <\/p>\n<p> to the following section for details.<\/p>\n<p>\u2022 If you use a 24-V brake, install a separate power supply for the 24-VDC power supply from other power  supplies, such as the one for the I\/O signals of the CN1 connector. If the power supply is shared, the I\/O  signals may malfunction. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-031.png\" \/><\/p>\n<p>BK-RY: Brake control relay <br \/>1D:Fly wheeling Diode <\/p>\n<h3>4.5 I\/O Signal Connections <\/h3>\n<h4>4.5.1 I\/O Signal Connector (CN1) Names and Functions <\/h4>\n<p>EtherCAT Type ( SC3 \u25af\u25af\u25af\u25af\u25af 00 )\uff1a <br \/>Default settings are given in parentheses. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Pin <br \/>No.<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>Pin <br \/>No. <\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>26 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>27 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>28 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>29 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>31 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>OUT0+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 0, Reallocatable (Default\uff1aALM) <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<td>\n<p>OUT3+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 3, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>OUT0- <\/p>\n<\/td>\n<td>\n<p>33 <\/p>\n<\/td>\n<td>\n<p>OUT3- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>9 <\/p>\n<\/td>\n<td>\n<p>OUT1+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 1, Reallocatable (Default\uff1a\/BK) <\/p>\n<\/td>\n<td>\n<p>34 <\/p>\n<\/td>\n<td>\n<p>OUT4+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 4, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 <\/p>\n<\/td>\n<td>\n<p>OUT1- <\/p>\n<\/td>\n<td>\n<p>35 <\/p>\n<\/td>\n<td>\n<p>OUT4- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>11 <\/p>\n<\/td>\n<td>\n<p>OUT2+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 2, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<td>\n<p>36 <\/p>\n<\/td>\n<td>\n<p>OUT5+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 5, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>12 <\/p>\n<\/td>\n<td>\n<p>OUT2- <\/p>\n<\/td>\n<td>\n<p>37 <\/p>\n<\/td>\n<td>\n<p>OUT5- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>13 <\/p>\n<\/td>\n<td>\n<p>DICOM <\/p>\n<\/td>\n<td>\n<p>input signal common terminal <\/p>\n<\/td>\n<td>\n<p>38 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>14 <\/p>\n<\/td>\n<td>\n<p>IN0 <\/p>\n<\/td>\n<td>\n<p>Input 0, Reallocatable (Default\uff1a\/P-OT)<\/p>\n<\/td>\n<td>\n<p>39 <\/p>\n<\/td>\n<td>\n<p>IN4 <\/p>\n<\/td>\n<td>\n<p>Input 4, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 <\/p>\n<\/td>\n<td>\n<p>IN1 <\/p>\n<\/td>\n<td>\n<p>Input 1, Reallocatable (Default\uff1a\/N-OT)<\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>IN5 <\/p>\n<\/td>\n<td>\n<p>Input 5, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>IN2 <\/p>\n<\/td>\n<td>\n<p>Input 2, Reallocatable (Default\uff1a\/DEC)<\/p>\n<\/td>\n<td>\n<p>41 <\/p>\n<\/td>\n<td>\n<p>IN6 <\/p>\n<\/td>\n<td>\n<p>Input 6, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>17 <\/p>\n<\/td>\n<td>\n<p>IN3 <\/p>\n<\/td>\n<td>\n<p>Input 3, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<td>\n<p>42 <\/p>\n<\/td>\n<td>\n<p>IN7 <\/p>\n<\/td>\n<td>\n<p>Input 7, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>18 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>43 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>19 <\/p>\n<\/td>\n<td>\n<p>PAO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PG Divided Pulse Output, Phase A<\/p>\n<\/td>\n<td>\n<p>44 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>20 <\/p>\n<\/td>\n<td>\n<p>PAO- <\/p>\n<\/td>\n<td>\n<p>45 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>21 <\/p>\n<\/td>\n<td>\n<p>PBO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PGDivided Pulse Output, Phase B <\/p>\n<\/td>\n<td>\n<p>46 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>22 <\/p>\n<\/td>\n<td>\n<p>PBO- <\/p>\n<\/td>\n<td>\n<p>47 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>23 <\/p>\n<\/td>\n<td>\n<p>PCO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PGDivided Pulse Output, Phase Z <\/p>\n<\/td>\n<td>\n<p>48 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>24 <\/p>\n<\/td>\n<td>\n<p>PCO- <\/p>\n<\/td>\n<td>\n<p>49 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>25 <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>Singal Ground <\/p>\n<\/td>\n<td>\n<p>50 <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>Singal Ground <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: 1\u3001The terminal displays &quot;&#8211;&quot;, please do not use\u3002 <\/p>\n<p>2\u3001Please connect the input and output signals to the connector by shielded cables. <\/p>\n<p>Pulses Type ( SC3 \u25af\u25af\u25af\u25af\u25af 10 )\uff1a <br \/>Default settings are given in parentheses <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Pin NO.<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>Pin NO.<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>APULS+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Pulse Reference Input <\/p>\n<\/td>\n<td>\n<p>26 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>APULS- <\/p>\n<\/td>\n<td>\n<p>27 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>BSIGN+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Sign of Reference Input (Line-Driver) <\/p>\n<\/td>\n<td>\n<p>28 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>BSIGN- <\/p>\n<\/td>\n<td>\n<p>29 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>ANA0+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed Reference <\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td>\n<p>ANA1+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Torque Refer-ence Input <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>ANA0- <\/p>\n<\/td>\n<td>\n<p>31 <\/p>\n<\/td>\n<td>\n<p>ANA1- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>OUT0+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 0,Reallocatable (Default\uff1aALM) <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<td>\n<p>OUT3+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 3, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>OUT0- <\/p>\n<\/td>\n<td>\n<p>33 <\/p>\n<\/td>\n<td>\n<p>OUT3- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>9 <\/p>\n<\/td>\n<td>\n<p>OUT1+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 1,Reallocatable (Default\uff1a\/COIN) <\/p>\n<\/td>\n<td>\n<p>34 <\/p>\n<\/td>\n<td>\n<p>OUT4+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 4, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 <\/p>\n<\/td>\n<td>\n<p>OUT1- <\/p>\n<\/td>\n<td>\n<p>35 <\/p>\n<\/td>\n<td>\n<p>OUT4- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>11 <\/p>\n<\/td>\n<td>\n<p>OUT2+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 2, Reallocatable (Default\uff1a\/BK) <\/p>\n<\/td>\n<td>\n<p>36 <\/p>\n<\/td>\n<td>\n<p>OUT5+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Output 5, Reallocatable (Factory reserved) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>12 <\/p>\n<\/td>\n<td>\n<p>OUT2- <\/p>\n<\/td>\n<td>\n<p>37 <\/p>\n<\/td>\n<td>\n<p>OUT5- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>13 <\/p>\n<\/td>\n<td>\n<p>DICOM <\/p>\n<\/td>\n<td>\n<p>input signal common terminal <\/p>\n<\/td>\n<td>\n<p>38 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>14 <\/p>\n<\/td>\n<td>\n<p>IN0 <\/p>\n<\/td>\n<td>\n<p>Input 0, Reallocatable (Default\uff1a\/S-ON)<\/p>\n<\/td>\n<td>\n<p>39 <\/p>\n<\/td>\n<td>\n<p>IN4 <\/p>\n<\/td>\n<td>\n<p>Input 4, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 <\/p>\n<\/td>\n<td>\n<p>IN1 <\/p>\n<\/td>\n<td>\n<p>Input 1, Reallocatable (Default\uff1a\/P-OT)<\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td>\n<p>IN5 <\/p>\n<\/td>\n<td>\n<p>Input 5, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>IN2 <\/p>\n<\/td>\n<td>\n<p>Input 2, Reallocatable (Default\uff1a\/N-OT)<\/p>\n<\/td>\n<td>\n<p>41 <\/p>\n<\/td>\n<td>\n<p>IN6 <\/p>\n<\/td>\n<td>\n<p>Input 6, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>17 <\/p>\n<\/td>\n<td>\n<p>IN3 <\/p>\n<\/td>\n<td>\n<p>Input 3, Reallocatable (Default\uff1a\/ALM-RST)<\/p>\n<\/td>\n<td>\n<p>42 <\/p>\n<\/td>\n<td>\n<p>IN7 <\/p>\n<\/td>\n<td>\n<p>Input 7, Reallocatable (Factory reserved)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>18 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>43 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>19 <\/p>\n<\/td>\n<td>\n<p>PAO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PG Divided Pulse Output, Phase A<\/p>\n<\/td>\n<td>\n<p>44 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>20 <\/p>\n<\/td>\n<td>\n<p>PAO- <\/p>\n<\/td>\n<td>\n<p>45 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>21 <\/p>\n<\/td>\n<td>\n<p>PBO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PG Divided Pulse Output, Phase B<\/p>\n<\/td>\n<td>\n<p>46 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>22 <\/p>\n<\/td>\n<td>\n<p>PBO- <\/p>\n<\/td>\n<td>\n<p>47 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>23 <\/p>\n<\/td>\n<td>\n<p>PCO+ <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PG Divided Pulse Output, Phase Z<\/p>\n<\/td>\n<td>\n<p>48 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>24 <\/p>\n<\/td>\n<td>\n<p>PCO- <\/p>\n<\/td>\n<td>\n<p>49 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>25 <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>Singal Ground <\/p>\n<\/td>\n<td>\n<p>50 <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>Singal Ground <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: 1\u3001The terminal displays &quot;&#8211;&quot;, please do not use\u3002 <\/p>\n<p>2\u3001Please connect the input and output signals to the connector by shielded cables. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>4.5.2 I\/O Signal C\t EtherCAT Type ( SC3 \u25af<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-032.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>onnector (CN1) Pin Arrangement \u25af\u25af\u25af\u25af 00 )\uff1a <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\"><\/td>\n<td rowspan=\"2\">\n<p>1<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td colspan=\"2\"><\/td>\n<td rowspan=\"2\">\n<p>26<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>2<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>27<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>3<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>28<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>4<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>29<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>5<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>30<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>6<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>31<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>7<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT0+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT3+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>8<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT0-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>33<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT3-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>9<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT1+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>34<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT4+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>10<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT1-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>35<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT4-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>11<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT2+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>36<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT5+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>12<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT2-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>37<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT5-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>13<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>DICOM<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>38<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>14<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN0 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>39<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN4 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>15<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN1 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>40<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN5 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>16<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN2 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>41<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN6 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>17<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN3 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>42<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN7 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>18<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>43<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>19<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PAO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>44<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>20<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PAO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>45<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>21<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PBO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>46<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>22<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PBO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>47<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>23<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PCO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>48<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>24<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PCO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>49<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>25<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>GND<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>50<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>GND<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pulses Type ( SC3 \u25af\u25af\u25af\u25af\u25af 10 )\uff1a <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-033.jpg\" \/><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\"><\/td>\n<td rowspan=\"2\">\n<p>1<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>APULS+<\/p>\n<\/td>\n<td colspan=\"2\"><\/td>\n<td rowspan=\"2\">\n<p>26<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>2<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>APULS-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>27<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>3<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>BSIGN+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>28<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>4<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>BSIGN-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>29<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>5<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>ANA0+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>30<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>ANA1+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>6<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>ANA0-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>31<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>ANA1-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>7<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT0+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT3+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>8<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT0-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>33<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT3-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>9<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT1+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>34<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT4+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>10<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT1-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>35<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT4-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>11<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT2+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>36<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT5+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>12<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT2-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>37<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>OUT5-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>13<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>DICOM<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>38<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>14<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN0 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>39<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN4 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>15<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN1 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>40<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN5 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>16<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN2 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>41<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN6 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>17<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN3 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>42<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>IN7 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>18<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>43<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>19<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PAO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>44<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>20<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PAO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>45<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>21<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PBO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>46<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>22<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PBO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>47<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>23<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PCO+<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>48<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>24<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>PCO-<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>49<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>25<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>GND<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>50<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>GND<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.5.3 I\/O Signal Wiring Examples <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25a0<\/p>\n<\/td>\n<td>\n<p>Communiaction Type\uff1a( SC3 \u25af\u25af\u25af\u25af\u25af 00 )\uff1aPostioning Control Mode <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-034.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-035.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-036.png\" \/><\/p>\n<p>\u25a0\tPulses Type ( SC3 \u25af\u25af\u25af\u25af\u25af 10 )\uff1aPostioning Control Mode <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-037.png\" \/><\/p>\n<p>\u25a0\tPulses Type ( SC3 \u25af\u25af\u25af\u25af\u25af 10 )\uff1aSpeed\/Torque Contorl Mode <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-038.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-039.png\" \/><\/p>\n<h4>4.5.4 Sequence Input and Output Circuits <\/h4>\n<p>Sequence Input Circuits <\/p>\n<p>\u25c6 Photocoupler Input Circuits <br \/>This section describes CN1 connector terminals CN1-IN0\uff5eCN1-IN7. The circuits are connected through relay or openollector transistor circuits. If you connect through a relay, use a low-current relay. If you do not use a low-current relay, a faulty contact may result. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-040.png\" \/><\/p>\n<p>NOTE: The 24-VDC external power supply capacity must be 50 mA minimum. <\/p>\n<p>The servo driver input circuits use bidirectional photocouplers. Select either a sink circuit or source circuit according to the specifications required by the machine. <\/p>\n<p>Please choose either the common collector configuration or the common emitter configuration based on the mechanical specifications. (\u4f3aServo Parameter Pn517~518) <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Sink Circuits <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Source Circuits <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-041.png\" \/><\/p>\n<\/td>\n<td colspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-042.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Input Signal Polarity <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Input Signal Polarity <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Photocoupler <\/p>\n<\/td>\n<td>\n<p>Internal Signal Leve <\/p>\n<\/td>\n<td>\n<p>Photocoupler <\/p>\n<\/td>\n<td>\n<p>Internal Signal Leve <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ON <\/p>\n<\/td>\n<td>\n<p>Low level <\/p>\n<\/td>\n<td>\n<p>ON <\/p>\n<\/td>\n<td>\n<p>High level <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF <\/p>\n<\/td>\n<td>\n<p>High level <\/p>\n<\/td>\n<td>\n<p>OFF <\/p>\n<\/td>\n<td>\n<p>Low level <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Sequence Output Circuit <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-043.png\" \/><\/p>\n<\/td>\n<td>\n<p>Incorrect wiring or incorrect voltage application to the output circuits may cause short-circuit failures. If a short-circuit failure occurs as a result of any of these causes, the holding brake will not work. This could damage the machine or cause an accident that may result in death or injury. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25c6 Open-Collector Output Circuits <br \/>The Alarm Code (ALO1, ALO2, and ALO3) signals are output from open-collector transistor output circuits. Connect an open-collector output circuit to a photocoupler, relay, or line-receiver circuit. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-044.png\" \/><\/p>\n<p>NOTE: The maximum allowable voltage and maximum allowable current for open-collector output circuits are as follows: \u2022 Maximum allowable voltage: 30 VDC <br \/>\u2022 Maximum allowable current: 20 mA DC<\/p>\n<p>\u25c6 Line-Driver Output Circuits <br \/>This section describes CN1-19\uff5e24 (Phase-A, B, Z Signal) <\/p>\n<p>The serial data from the encoder is converted to two-phase (phases A and B) pulses. The resulting output signals (PAO, \/PAO and PBO, \/PBO), origin pulse signal (PCO and \/PCO), and the absolute encoder position output signals (PSO and \/PSO) are output with line-driver output circuits. Connect the line-driver output circuits to line-receiver circuits at the host controller. <\/p>\n<p>Example for Line-Receiver Circuit <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-045.png\" \/><\/p>\n<h3>4.6 Encoder Connector Names <\/h3>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Pin No. <\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>5V <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>E+ <\/p>\n<\/td>\n<td>\n<p>E- <\/p>\n<\/td>\n<td>\n<p>SD+ <\/p>\n<\/td>\n<td>\n<p>SD- <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE:SD+\u3001SD-are Pin of Data\uff1bE+\u3001E-are Pin of Battery\u3002 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-046.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"10\">\n<p>Encoder Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>9 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>SD+<\/p>\n<\/td>\n<td>\n<p>SD-<\/p>\n<\/td>\n<td>\n<p>E+<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>5V<\/p>\n<\/td>\n<td>\n<p>0V<\/p>\n<\/td>\n<td>\n<p>E-<\/p>\n<\/td>\n<td>\n<p>PE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"5\">\n<p>Power Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>U <\/p>\n<\/td>\n<td>\n<p>V <\/p>\n<\/td>\n<td>\n<p>W <\/p>\n<\/td>\n<td>\n<p>PE <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>Brake Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>24V<\/p>\n<\/td>\n<td>\n<p>0V <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Encoder <\/p>\n<\/td>\n<td>\n<p>Power <\/p>\n<\/td>\n<td>\n<p>Brake <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-047.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"10\">\n<p>Encoder Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>9 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>5V<\/p>\n<\/td>\n<td>\n<p>0V<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>E+<\/p>\n<\/td>\n<td>\n<p>SD+<\/p>\n<\/td>\n<td>\n<p>SD-<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>E-<\/p>\n<\/td>\n<td>\n<p>PE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"5\">\n<p>Power Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>A <\/p>\n<\/td>\n<td>\n<p>B <\/p>\n<\/td>\n<td>\n<p>C <\/p>\n<\/td>\n<td>\n<p>D <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>U <\/p>\n<\/td>\n<td>\n<p>V <\/p>\n<\/td>\n<td>\n<p>W <\/p>\n<\/td>\n<td>\n<p>PE <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>Brake Cable Pins <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Num<\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Def<\/p>\n<\/td>\n<td>\n<p>24V<\/p>\n<\/td>\n<td>\n<p>0V <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Encoder <\/p>\n<\/td>\n<td>\n<p>Power <\/p>\n<\/td>\n<td>\n<p>Brake <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-048.png\" \/><\/p>\n<h3>4.7 EtherCAT Connector Names <\/h3>\n<p>EtherCAT Type ( SC3 \u25af\u25af\u25af\u25af\u25af 00 )\uff1a <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Pin Number <\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>8 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Name<\/p>\n<\/td>\n<td>\n<p>CN3 <\/p>\n<\/td>\n<td>\n<p>TX_P_IN <\/p>\n<\/td>\n<td>\n<p>TX_N_IN <\/p>\n<\/td>\n<td>\n<p>RX_P_IN <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RX_N_IN <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CN4 <\/p>\n<\/td>\n<td>\n<p>TX_P_OUT<\/p>\n<\/td>\n<td>\n<p>TX_N_OUT<\/p>\n<\/td>\n<td>\n<p>RX_P_OUT<\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RX_N_OUT<\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pulses Type ( SC3 \u25af\u25af\u25af\u25af\u25af 10 )\uff1a <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Pin Number <\/p>\n<\/td>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>8 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Name<\/p>\n<\/td>\n<td>\n<p>CN3 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RS485+<\/p>\n<\/td>\n<td>\n<p>RS485- <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CN4 <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td>\n<p>GND <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Build-in 120\u03a9<\/p>\n<\/td>\n<td>\n<p>RS485+<\/p>\n<\/td>\n<td>\n<p>RS485- <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-04\/sc3-sc3man-en-04-049.png\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>4.1 Precautions related to wiring 4.1.1 General Precaut [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3299","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3299"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3299\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3299"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3299"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}