{"id":3302,"date":"2026-11-17T18:40:55","date_gmt":"2026-11-17T10:40:55","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-07\/"},"modified":"2026-11-17T18:40:55","modified_gmt":"2026-11-17T10:40:55","slug":"sc3-sc3man-en-07","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-07\/","title":{"rendered":"Chapter 7 Trial Operation and Actual Operation"},"content":{"rendered":"<p>This chapter provides information on the flow and procedures for trial operation and convenient functions to use during trial operation. <\/p>\n<h3>7.1 Flow of Trial Operation <\/h3>\n<h4>7.1.1 Flow of Trial Operation for Rotary Servomotors <\/h4>\n<p>The procedure for trial operation is given below. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Step<\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Installation <br \/>Install the Servomotor and servo driver according to the installation conditions. First, operation is checked with no load. Do not connect the Servomotor to the machine.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Wiring and Connections <br \/>Wire and connect the servo driver. First, Servomotor operation is checked without a load. Do not connect the CN1 connector on the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>Confirmations before Trial Operation <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>Power ON <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>Resetting the Absolute Encoder <br \/>This step is necessary only for a Servomotor with an Absolute Encoder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>7.2 Inspections and Confirmations before Trial Operation <\/h3>\n<p>To ensure safe and correct trial operation, check the following items before you start trial operation. <\/p>\n<p>\u2022 Make sure that the servo driver and Servomotor are installed, wired, and connected correctly. <\/p>\n<p>\u2022 Make sure that the correct power supply voltage is supplied to the servo driver. <\/p>\n<p>\u2022 Make sure that there are no loose parts in the Servomotor mounting. <\/p>\n<p>\u2022 If you are using a Servomotor with an Oil Seal, make sure that the oil seal is not damaged. <\/p>\n<p>Also make sure that oil has been applied. <\/p>\n<p>\u2022 If you are performing trial operation on a Servomotor that has been stored for a long period of time, make sure that all Servomotor inspection and maintenance procedures have been completed. <\/p>\n<p>Refer to the manual for your Servomotor for Servomotor maintenance and inspection information. <\/p>\n<p>\u2022 If you are using a Servomotor with a Holding Brake, make sure that the brake is released in advance. To release the brake, you must apply the specified voltage of 24 VDC to the brake. <\/p>\n<p>A circuit example for trial operation is provided below. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-07\/sc3-sc3man-en-07-001.jpg\" \/><\/p>\n<h3>7.3 Trial Operation for the Servomotor without a Load <\/h3>\n<p>You use jogging for trial operation of the Servomotor without a load. <\/p>\n<p>Jogging is used to check the operation of the Servomotor without connecting the servo driver to the host controller. The Servomotor is moved at the preset jogging speed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-07\/sc3-sc3man-en-07-002.png\" \/>CAUTION <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cf During jogging, the overtravel function is disabled. Consider the range of motion of your machine when you  jog the Servomotor. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>7.3.1 Preparations <\/h4>\n<p>Always check the following before you execute jogging. <\/p>\n<p>\u2022 The parameters must not be write prohibited. <\/p>\n<p>\u2022 The main circuit power supply must be ON. <\/p>\n<p>\u2022 There must be no alarms. <\/p>\n<p>\u2022 There must be no hard wire base block (HWBB). <\/p>\n<p>\u2022 The servo must be OFF. <\/p>\n<p>\u2022 The jogging speed must be set considering the operating range of the machine. The jogging speed is set with the following parameters. <\/p>\n<p>*1: STO is an optional function. <\/p>\n<p>Rotary Servomotors <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn304 <\/p>\n<\/td>\n<td colspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Jogging Speed<\/p>\n<\/td>\n<td>\n<p> Speed     Position     Torque <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p> Torque <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setup Range <\/p>\n<\/td>\n<td>\n<p>Setup Unit <\/p>\n<\/td>\n<td>\n<p>default setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0\uff5e10000<\/p>\n<\/td>\n<td>\n<p>1 min-1 (RPM) <\/p>\n<\/td>\n<td>\n<p>500 <\/p>\n<\/td>\n<td>\n<p>immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn305 <\/p>\n<\/td>\n<td colspan=\"7\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Soft Start Acceleration Time<\/p>\n<\/td>\n<td>\n<p> Speed     Position     Torque <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setup Range <\/p>\n<\/td>\n<td>\n<p>Setup Unit <\/p>\n<\/td>\n<td>\n<p>default setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0\uff5e10000<\/p>\n<\/td>\n<td>\n<p>1 ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn306 <\/p>\n<\/td>\n<td colspan=\"7\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Soft Start Deceleration Time<\/p>\n<\/td>\n<td>\n<p> Speed     Position     Torque <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setup Range <\/p>\n<\/td>\n<td>\n<p>Setup Unit <\/p>\n<\/td>\n<td>\n<p>default setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0\uff5e10000<\/p>\n<\/td>\n<td>\n<p>1 ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>7.3.2 Applicable Tools <\/h4>\n<p>The following table lists the tools that you can use to perform jogging <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>FA No.\/Function Name <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td>\n<p>FA002 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ProTuner <\/p>\n<\/td>\n<td>\n<p>Operation &#8211; Jog \t<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-07\/sc3-sc3man-en-07-003.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This chapter provides information on the flow and proce [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3302","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3302","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3302"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3302\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3302"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3302"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}