{"id":3304,"date":"2026-11-17T18:41:16","date_gmt":"2026-11-17T10:41:16","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-09\/"},"modified":"2026-11-17T18:41:16","modified_gmt":"2026-11-17T10:41:16","slug":"sc3-sc3man-en-09","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-09\/","title":{"rendered":"Chapter 9 Maintenance"},"content":{"rendered":"<h3>9.1 Inspections and Part Replacement <\/h3>\n<p>This section describes inspections and part replacement for SERVO DRIVER. <\/p>\n<h4>9.1.1 Inspections <\/h4>\n<p>Perform the inspections given in the following table at least once every year for the servo driver. Daily inspections are not required. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item <\/p>\n<\/td>\n<td>\n<p>Frequency <\/p>\n<\/td>\n<td>\n<p>Inspection <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Exterior <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>At least once a year <\/p>\n<\/td>\n<td>\n<p>Check for dust, dirt, and oil on the surfaces. <\/p>\n<\/td>\n<td>\n<p>Clean with compressed air or a cloth. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Loose Screws<\/p>\n<\/td>\n<td>\n<p>Check for loose terminal block and connector screws and for other <br \/>loose parts. <\/p>\n<\/td>\n<td>\n<p>Tighten any loose screws or other loose parts. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>9.1.2 Replacing the Battery <\/h4>\n<p>If the battery voltage drops to approximately 3V or less, an A.830 alarm (Encoder Battery Alarm) or an A.930 warning (Absolute Encoder Battery Error) will be displayed. <\/p>\n<p>Battery Alarm\/Warning Selection <\/p>\n<p>Whether to display an alarm or a warning is determined by the setting of Pn008 = n.\u25af\u25af\u25afX (Low Battery Voltage Alarm\/Warning Selection).. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When <br \/>Enabled<\/p>\n<\/td>\n<td>\n<p>Classification<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn008 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Output alarm for low battery voltage (A.830). <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>After restart<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Output warning for low battery voltage (A.930).<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022 Pn008=n.\u25af\u25af\u25af0 <br \/>\u2022The ALM (Servo Alarm) signal is output for up to five seconds when the control power supply is turned ON, and then the battery voltage is monitored for four seconds. <\/p>\n<p>No alarm will be displayed even if the battery voltage drops below the specified value after these four seconds. <\/p>\n<p>\u2022 Pn008=n.\u25af\u25af\u25af1 <br \/>\u2022The ALM (Servo Alarm) signal is output for up to five seconds when the control power supply \tis turned ON, and then the battery voltage is monitored continuously. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-001.jpg\" \/><\/p>\n<p>\u25c6When Using an Encoder Cable with a Battery Case <\/p>\n<p>1.Turn ON only the control power supply to the servo driver.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-002.png\" \/><\/p>\n<\/td>\n<td>\n<p>If you remove the Battery or disconnect the Encoder Cable while the control power supply to the servo driver is OFF, the absolute encoder data will be lost. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>2.Open the cover of the Battery Case <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-003.png\" \/><\/p>\n<p>3.Remove the old Battery and mount a new Battery. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-004.png\" \/><\/p>\n<p>4.Close the cover of the Battery Case. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-005.png\" \/><\/p>\n<p>5.Turn OFF the power supply to the servo driver to clear the A.830 alarm (Encoder Battery Alarm). <\/p>\n<p>6.Turn ON the power supply to the servo driver. <\/p>\n<p>7.Make sure that the alarm has been cleared and that the servo driver operates normally. <\/p>\n<h3>9.2 Alarm Displays <\/h3>\n<p>If an error occurs in the servo driver, an alarm number will be displayed on the panel display. Example: If an A.020 alarm occurs, <br \/>\u201c020\u201d will flash on the display\uff1a <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-006.png\" \/><\/p>\n<h4>9.2.1 List of Alarms <\/h4>\n<p>The list of alarms gives the alarm name, alarm meaning, alarm stopping method, alarm reset possibility, and alarm code output in order of the alarm numbers. <\/p>\n<p>Alarm Reset Possibility <\/p>\n<p>Yes: You can use an alarm reset to clear the alarm. However, this assumes that the cause of the alarm has been removed. <br \/>No: You cannot clear the alarm. <\/p>\n<p>List of Alarms <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Alarm <br \/>Number <\/p>\n<\/td>\n<td>\n<p>Alarm Name <\/p>\n<\/td>\n<td>\n<p>Alarm Meaning <\/p>\n<\/td>\n<td>\n<p>Servomotor Stopping <br \/>Method<\/p>\n<\/td>\n<td>\n<p>Alarm <br \/>Reset <br \/>Possible<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.020<\/p>\n<\/td>\n<td>\n<p>Parameter Checksum Error<\/p>\n<\/td>\n<td>\n<p>There is an error in the parameter data in the servo driver.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.021 <\/p>\n<\/td>\n<td>\n<p>Parameter Format Error <\/p>\n<\/td>\n<td>\n<p>There is an error in the parameter data format in the servo driver.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.022<\/p>\n<\/td>\n<td>\n<p>System Checksum Error<\/p>\n<\/td>\n<td>\n<p>There is an error in the parameter data in the servo driver.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.030<\/p>\n<\/td>\n<td>\n<p>Main Circuit DetectorError<\/p>\n<\/td>\n<td>\n<p>There is an error in the detection data for the main circuit.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.040<\/p>\n<\/td>\n<td>\n<p>Parameter Setting Error<\/p>\n<\/td>\n<td>\n<p>A parameter setting is outside of the setting range.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.042 <\/p>\n<\/td>\n<td>\n<p>Parameter Combination Error <\/p>\n<\/td>\n<td>\n<p>The combination of some parameters exceeds the setting range.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.050 <\/p>\n<\/td>\n<td>\n<p>Combination Error <\/p>\n<\/td>\n<td>\n<p>The capacities of the servo driver and Servomotor do not match.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.051 <\/p>\n<\/td>\n<td>\n<p>Unsupported Device Alarm <\/p>\n<\/td>\n<td>\n<p>An unsupported device was connected. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.0b0 <\/p>\n<\/td>\n<td>\n<p>Invalid Servo ON Command Alarm <\/p>\n<\/td>\n<td>\n<p>The \/S-ON (Servo ON) signal was input from the host controller <br \/>after a utility function that turns ON the Servomotor was executed.<\/p>\n<\/td>\n<td>\n<p> Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.100 <\/p>\n<\/td>\n<td>\n<p>Overcurrent Detected <\/p>\n<\/td>\n<td>\n<p>An overcurrent flowed through the power transistor or the heat sink overheated.<\/p>\n<\/td>\n<td>\n<p> Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.101 <\/p>\n<\/td>\n<td>\n<p>Motor Overcurrent Detected <\/p>\n<\/td>\n<td>\n<p>The current to the motor exceeded the allowable current <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.300<\/p>\n<\/td>\n<td>\n<p>Regeneration Error<\/p>\n<\/td>\n<td>\n<p>There is an error related to regeneration.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.320 <\/p>\n<\/td>\n<td>\n<p>Regenerative Overload <\/p>\n<\/td>\n<td>\n<p>A regenerative overload occurred. <\/p>\n<\/td>\n<td>\n<p>Gr.2 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.330 <\/p>\n<\/td>\n<td>\n<p>Main Circuit Power Supply Wiring Error <\/p>\n<\/td>\n<td>\n<p>\u2022 The AC power supply input setting or DC power supply input setting is not correct. <\/p>\n<p>\u2022The power supply wiring is not correct.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.400<\/p>\n<\/td>\n<td>\n<p>Overvoltage<\/p>\n<\/td>\n<td>\n<p>The main circuit DC voltage is too high.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.410<\/p>\n<\/td>\n<td>\n<p>Undervoltage<\/p>\n<\/td>\n<td>\n<p>The main circuit DC voltage is too low.<\/p>\n<\/td>\n<td>\n<p>Gr.2<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.510<\/p>\n<\/td>\n<td>\n<p>Overspeed<\/p>\n<\/td>\n<td>\n<p>The motor exceeded the maximum speed.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.520<\/p>\n<\/td>\n<td>\n<p>Vibration Alarm<\/p>\n<\/td>\n<td>\n<p>Abnormal oscillation wasdetected in the motor speed.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>Yes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.521 <\/p>\n<\/td>\n<td>\n<p>Autotuning Alarm <\/p>\n<\/td>\n<td>\n<p>Vibration was detected during autotuning for the tuning-less function. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.600 <\/p>\n<\/td>\n<td>\n<p>Incorrect ESM requires exception protection <\/p>\n<\/td>\n<td>\n<p>Received a state conversion request that cannot be converted from the current state. <\/p>\n<\/td>\n<td>\n<p>\tGr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.601 <\/p>\n<\/td>\n<td>\n<p>Undefined ESM requires exception protection<\/p>\n<\/td>\n<td>\n<p>Undefined state transition request received. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.602 <\/p>\n<\/td>\n<td>\n<p>Boot state requires exception protection<\/p>\n<\/td>\n<td>\n<p>Received Bootstrap status conversion request. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.603 <\/p>\n<\/td>\n<td>\n<p>PLL incomplete exception protection <\/p>\n<\/td>\n<td>\n<p>After 1 second of synchronization processing, the bit combination of communication and servo still cannot be completed.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.604 <\/p>\n<\/td>\n<td>\n<p>PDO watchdog exception protection<\/p>\n<\/td>\n<td>\n<p>When SP or OP, bit10 of ESC register 0200h does not turn ON within the specified time.<\/p>\n<\/td>\n<td>\n<p> \tGr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.605 <\/p>\n<\/td>\n<td>\n<p>ESC hardware initialization error<\/p>\n<\/td>\n<td>\n<p>ESC hardware initialization error. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.606 <\/p>\n<\/td>\n<td>\n<p>PLL abnormal protection <\/p>\n<\/td>\n<td>\n<p>The ESM status is under SP or OP, and the communication and servo bits do not match. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.607 <\/p>\n<\/td>\n<td>\n<p>Synchronous signal abnormality protection<\/p>\n<\/td>\n<td>\n<p>After the synchronization process is completed, the SYNC0 or IRQ interrupt processing times out.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.610 <\/p>\n<\/td>\n<td>\n<p>Synchronization cycle setting abnormality protection<\/p>\n<\/td>\n<td>\n<p>Unsupported synchronization period (SYNC0) is set. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.611 <\/p>\n<\/td>\n<td>\n<p>Email settings abnormality protection<\/p>\n<\/td>\n<td>\n<p>The SM0\/1 setting of the mailbox is incorrect. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.614 <\/p>\n<\/td>\n<td>\n<p>PDO watchdog setting abnormal protection<\/p>\n<\/td>\n<td>\n<p>PDO watchdog setting error. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.615 <\/p>\n<\/td>\n<td>\n<p>DC setting abnormality protection <\/p>\n<\/td>\n<td>\n<p>DC setting error. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.616 <\/p>\n<\/td>\n<td>\n<p>SM event mode setting abnormality protection <\/p>\n<\/td>\n<td>\n<p>Unsupported SM event is set. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.617 <\/p>\n<\/td>\n<td>\n<p>SM2\/3 setting abnormality protection<\/p>\n<\/td>\n<td>\n<p>SM2\/3 is set to an incorrect value. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.650 <\/p>\n<\/td>\n<td>\n<p>TxPDO allocation exception protection<\/p>\n<\/td>\n<td>\n<p>The data size mapped by TxPDO exceeds 32 bytes. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.651 <\/p>\n<\/td>\n<td>\n<p>RxPDO allocation exception protection<\/p>\n<\/td>\n<td>\n<p>RxPDO mapped data size exceeds 32 bytes. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.652 <\/p>\n<\/td>\n<td>\n<p>Lost link exception protection <\/p>\n<\/td>\n<td>\n<p>After ESM leaves the Init state, Port0 or 1 appears in the lost link state.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.710 <\/p>\n<\/td>\n<td>\n<p>Instantaneous Overload <\/p>\n<\/td>\n<td>\n<p>The Servomotor was operating for several seconds to several tens of seconds under a torque that largely exceeded the rating.<\/p>\n<\/td>\n<td>\n<p>Gr.2 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>A.720 <\/p>\n<\/td>\n<td>\n<p>Continuous Overload <\/p>\n<\/td>\n<td>\n<p>The Servomotor was operating continuously under a torque that exceeded the rating.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.730\/1 <\/p>\n<\/td>\n<td>\n<p>Dynamic Brake Overload <\/p>\n<\/td>\n<td>\n<p>When the dynamic brake was applied, the rotational or linear kinetic energy exceeded the capacity of the dynamic brake resistor. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.740 <\/p>\n<\/td>\n<td>\n<p>Inrush Current Limiting Resistor Overload<\/p>\n<\/td>\n<td>\n<p>The main circuit power supply was frequently turned ON and OFF.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.810 <\/p>\n<\/td>\n<td>\n<p>Encoder Backup Alarm <\/p>\n<\/td>\n<td>\n<p>The power supplies to the encoder all failed and the position data was lost.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.820 <\/p>\n<\/td>\n<td>\n<p>Encoder Checksum Alarm <\/p>\n<\/td>\n<td>\n<p>There is an error in the checksum results for encoder memory.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.830 <\/p>\n<\/td>\n<td>\n<p>Encoder Battery Alarm <\/p>\n<\/td>\n<td>\n<p>The battery voltage was lower than the specified level after the control power supply was turned ON.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.840<\/p>\n<\/td>\n<td>\n<p>Encoder Data Alarm<\/p>\n<\/td>\n<td>\n<p>There is an internal data errorin the encoder.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.850 <\/p>\n<\/td>\n<td>\n<p>Encoder Overspeed <\/p>\n<\/td>\n<td>\n<p>The encoder was operating at high speed when the power was turned ON.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C10 <\/p>\n<\/td>\n<td>\n<p>Servomotor Out of Control <\/p>\n<\/td>\n<td>\n<p>The Servomotor ran out of control. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C20<\/p>\n<\/td>\n<td>\n<p>Phase Detection Error<\/p>\n<\/td>\n<td>\n<p>The detection of the phase is not correct.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C22 <\/p>\n<\/td>\n<td>\n<p>Phase Information Disagreement<\/p>\n<\/td>\n<td>\n<p>The phase information does not match. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C90 <\/p>\n<\/td>\n<td>\n<p>Encoder Communications Error<\/p>\n<\/td>\n<td>\n<p>Communications between the encoder and servo driver is not possible.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C91 <\/p>\n<\/td>\n<td>\n<p>Encoder Communications Position Data Acceleration Rate Error<\/p>\n<\/td>\n<td>\n<p>An error occurred in calculating the position data of the encoder. <\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C92 <\/p>\n<\/td>\n<td>\n<p>Encoder Communications Timer Error<\/p>\n<\/td>\n<td>\n<p>An error occurred in the communications timer between the encoder and servo driver.<\/p>\n<\/td>\n<td>\n<p> Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.CA0<\/p>\n<\/td>\n<td>\n<p>Encoder Parameter Error<\/p>\n<\/td>\n<td>\n<p>The parameters in the encoder are corrupted.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.Cb0 <\/p>\n<\/td>\n<td>\n<p>Encoder Echoback Error <\/p>\n<\/td>\n<td>\n<p>The contents of communications with the encoder are incorrect.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d00 <\/p>\n<\/td>\n<td>\n<p>Position Deviation Overflow <\/p>\n<\/td>\n<td>\n<p>The setting of Pn520 (Position Deviation Overflow Alarm Level) was exceeded by the position deviation while the servo was ON.<\/p>\n<\/td>\n<td>\n<p>Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d01 <\/p>\n<\/td>\n<td>\n<p>Position Deviation <br \/>Overflow Alarm at Servo ON <\/p>\n<\/td>\n<td>\n<p>The servo was turned ON after the position deviation exceeded the setting of Pn526 (Position Deviation Overflow Alarm Level at Servo ON) while the servo was OFF. <\/p>\n<\/td>\n<td>\n<p> Gr.1 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d02 <\/p>\n<\/td>\n<td>\n<p>Position Deviation <br \/>Overflow Alarm for Speed Limit at Servo ON <\/p>\n<\/td>\n<td>\n<p>If position deviation remains in the deviation counter, the setting of Pn529 or Pn584 (Speed Limit Level at Servo ON) limits the speed when the servo is turned ON. This alarm occurs if reference <br \/>pulses are input and the setting of Pn520 (Position Deviation Overflow Alarm Level) is exceeded before the limit is cleared.\u3002<\/p>\n<\/td>\n<td>\n<p> Gr.2 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d10 <\/p>\n<\/td>\n<td>\n<p>Motor-Load Position Deviation Overflow <\/p>\n<\/td>\n<td>\n<p>There was too much position deviation between the motor and load during fully-closed loop control. <\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>Gr.2 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d30<\/p>\n<\/td>\n<td>\n<p>Position Data Overflow<\/p>\n<\/td>\n<td>\n<p>The position feedback dataexceeded \u00b11,879,048,192.<\/p>\n<\/td>\n<td>\n<p>Gr.1<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.F10 <\/p>\n<\/td>\n<td>\n<p>Power Supply Line Open Phase<\/p>\n<\/td>\n<td>\n<p>The voltage was low for more than one second for phase R, S, or T when the mainpower supply was ON.<\/p>\n<\/td>\n<td>\n<p> Gr.2 <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* These alarms are not stored in the alarm history. They are only displayed on the panel display\u3002 <\/p>\n<h4>9.2.2 Troubleshooting Alarms <\/h4>\n<p>The causes of and corrections for the alarms are given in the following table. Contact your Fatek representative if you cannot solve a problem with the correction given in the table. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Alarm Number: Alarm Name<\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>A.020\uff1a <br \/>Parameter <br \/>Checksum Error (There is an error in the parameter data in the <br \/>servo driver.) <\/p>\n<\/td>\n<td>\n<p>The power supply voltage suddenly <br \/>dropped.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage.<\/p>\n<\/td>\n<td>\n<p>Set the power supply voltage within the specified range, and initialize the <br \/>parameter settings.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power supply was shut OFF while writing parameter settings.<\/p>\n<\/td>\n<td>\n<p>Check the timing of shutting OFF the power supply. <\/p>\n<\/td>\n<td>\n<p>Initialize the parameter settings and then set the parameters again. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The number of times that parameters were written exceeded the limit. <\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>parameters were frequently changed from <br \/>the host controller. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<p>Reconsider the method for writing the parameters<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A malfunction was <br \/>caused by noise from <br \/>the AC power supply, <br \/>ground, static electricity, or other source. <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver <br \/>OFF and ON again. If the alarm still occurs, noise may be the <br \/>cause.<\/p>\n<\/td>\n<td>\n<p>Implement countermeasures against noise. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>Gas, water drops, or cutting oil entered the servo driver and <br \/>caused failure of the internal components.<\/p>\n<\/td>\n<td>\n<p>Check the installation conditions. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.021\uff1a <br \/>Parameter Format Error <br \/>(There is an error in the parameter data format in the servo driver.) <\/p>\n<\/td>\n<td>\n<p>The software version <br \/>of the servo driver <br \/>that caused the alarm <br \/>is older than the software version of the <br \/>parameters specified <br \/>to write.<\/p>\n<\/td>\n<td>\n<p>Read the product information to see if the software <br \/>versions are the <br \/>same. If they are different, <br \/>it could be the <br \/>cause of the alarm. <\/p>\n<\/td>\n<td>\n<p>Write the parameters from another servo driver with the same model and the same software version, <br \/>and then turn the power OFF and ON again. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.022\uff1a <br \/>System Checksum Error <br \/>(There is an error in the parameter data in the <br \/>servo driver.) <\/p>\n<\/td>\n<td>\n<p>The power supply voltage suddenly dropped.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power supply <br \/>was shut OFF while <br \/>setting a utility function. <\/p>\n<\/td>\n<td>\n<p>Check the timing of <br \/>shutting OFF the power supply. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver <br \/>OFF and ON again. If the alarm still occurs, the servo driver may have failed. <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.030\uff1a <br \/>Main Circuit <br \/>Detector Error<\/p>\n<\/td>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>A.040\uff1a <br \/>Parameter Setting <br \/>Error <br \/>(A parameter setting is outside of <br \/>the setting <br \/>range.) <\/p>\n<\/td>\n<td>\n<p>The servo driver and Servomotor capacities do not match <br \/>each other.<\/p>\n<\/td>\n<td>\n<p>Check the combination of the servo driver and Servomotor capacities. <\/p>\n<\/td>\n<td>\n<p>Select a proper combination of servo driver and <br \/>Servomotor capacities. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A parameter setting is outside of the setting range. <\/p>\n<\/td>\n<td>\n<p>Check the setting <br \/>ranges of the parameters that have been <br \/>changed.<\/p>\n<\/td>\n<td>\n<p>Set the parameters to values within the setting <br \/>ranges. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The electronic gear ratio is outside of the setting range. <\/p>\n<\/td>\n<td>\n<p>Check the electronic <br \/>gear ratio. The ratio <br \/>must be within the following range: 0.001 &lt; <br \/>(Pn20E\/Pn210) &lt; <br \/>64,000.<\/p>\n<\/td>\n<td>\n<p>Set the electronic gear ratio in the following range: 0.001 &lt; (Pn20E\/ Pn210) &lt; 64,000. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.042\uff1a <br \/>Parameter <br \/>Combination Error <\/p>\n<\/td>\n<td>\n<p>The speed of program <br \/>jogging went below <br \/>the setting range <br \/>when the electronic <br \/>gear ratio (Pn20E\/ <br \/>Pn210) or the Servomotor was changed. <\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>detection conditions*1 are satisfied. <\/p>\n<\/td>\n<td>\n<p>Decrease the setting of the electronic gear ratio (Pn20E\/Pn210). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The speed of program <br \/>jogging went below the <br \/>setting range <br \/>when Pn533(Program <br \/>Jogging Movement Speed) was changed.<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>detection conditions*1 are satisfied. <\/p>\n<\/td>\n<td>\n<p>Increase the setting of <br \/>Pn533. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The movement speed of advanced autotuning went below the <br \/>setting range when <br \/>the electronic gear <br \/>ratio (Pn20E\/ Pn210) <br \/>or the Servomotor <br \/>was changed. <\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>detection conditions*2 are satisfied. <\/p>\n<\/td>\n<td>\n<p>Decrease the setting of the electronic gear ratio (Pn20E\/Pn210). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.050\uff1a <br \/>Combination <br \/>Error <br \/>(The capacities of<\/p>\n<\/td>\n<td>\n<p>The servo driver and Servomotor capacities do not match <br \/>each other.<\/p>\n<\/td>\n<td>\n<p>Confirm that the following condition is met: <br \/>1\/4 \u2264 (Servomotor <\/p>\n<\/td>\n<td>\n<p>Select a proper combination of the servo driver <br \/>and Servomotor capacities. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>the servo driver and Servomotor do not match.) <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>capacity\/servo driver capacity) \u2264 4<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.051\uff1a <br \/>Unsupported Device Alarm <\/p>\n<\/td>\n<td>\n<p>The motor parameter file was not written to the linear encoder. <\/p>\n<p>(This applies only <br \/>when not using a <br \/>Serial Converter Unit.)<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>motor parameter file <br \/>was written to the linear encoder. <\/p>\n<\/td>\n<td>\n<p>Write the motor parameter file to the linear <br \/>encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.0b0\uff1a <br \/>Invalid Servo ON Command Alarm <\/p>\n<\/td>\n<td>\n<p>The \/S-ON (Servo ON) signal was input from the host controller <br \/>after a utility function that turns ON the <br \/>Servomotor <br \/>was executed. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. Or, execute a software reset. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\">\n<p>A.100\uff1a <br \/>Overcurrent <br \/>Detected <br \/>(An overcurrent <br \/>flowed through <br \/>the power transistor or the heat <br \/>sink overheated.) <\/p>\n<\/td>\n<td>\n<p>The Main Circuit <br \/>Cable is not wired correctly or there is faulty contact.<\/p>\n<\/td>\n<td>\n<p>Check the wiring. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a short-circuit or ground fault in a <br \/>Main Circuit Cable. <\/p>\n<\/td>\n<td>\n<p>Check for short-circuits across Servomotor <br \/>phases U, V, and W, or between the ground <br \/>and Servomotor phases U, V, and W.<\/p>\n<\/td>\n<td>\n<p>The cable may be shortcircuited. Replace the <br \/>cable. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a short-circuit or ground fault inside the Servomotor. <\/p>\n<\/td>\n<td>\n<p>Check for short-circuits across Servomotor <br \/>phases U, V, and W, or between the ground <br \/>and Servomotor phases U, V, or W. <\/p>\n<\/td>\n<td>\n<p>The Servomotor may be <br \/>faulty. Replace the Servomotor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The regenerative <br \/>resistor is not wired correctly or there is faulty contact.<\/p>\n<\/td>\n<td>\n<p>Check the wiring. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The dynamic brake (DB, emergency stop executed from the <br \/>servo driver) was <br \/>frequently activated, or a DB overload <br \/>alarm occurred. <\/p>\n<\/td>\n<td>\n<p>Check the power consumed by the DB resistor <br \/>to see how <br \/>frequently the DB is <br \/>being used. Or, check <br \/>the alarm display to see <br \/>if a DB overload alarm <br \/>(A.730 or A.731) has <br \/>occurred.<\/p>\n<\/td>\n<td>\n<p>Change the servo driver <br \/>model, operating methods, or the mechanisms <br \/>so that the dynamic brake does not need to be used so frequently. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The regenerative processing capacity was <br \/>exceeded. <\/p>\n<\/td>\n<td>\n<p>Tab Page to see how <br \/>frequently the regenerative resistor is being <br \/>used. <\/p>\n<\/td>\n<td>\n<p>Recheck the operating <br \/>conditions and load. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The servo driver <br \/>regenerative resistance is too small. <\/p>\n<\/td>\n<td>\n<p>Tab Page to see how <br \/>frequently the regenerative resistor is being <br \/>used. <\/p>\n<\/td>\n<td>\n<p>Change the regenerative resistance to a value <br \/>larger than the servo driver minimum allowable <br \/>resistance. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A heavy load was applied while the <br \/>Servomotor <br \/>was stopped <br \/>or running at a low speed <\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>operating conditions exceed Servo Drive specifications. <\/p>\n<\/td>\n<td>\n<p>Reduce the load applied to the Servomotor. Or, increase the operating speed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A malfunction was caused by noise. <\/p>\n<\/td>\n<td>\n<p>Improve the noise environment, e.g. by <br \/>improving the wiring or <br \/>installation conditions, <br \/>and check to see if the <br \/>alarm still occurs.<\/p>\n<\/td>\n<td>\n<p>Implement countermeasures against noise, such <br \/>as correct wiring of the <br \/>FG. Use an FG wire size <br \/>equivalent to the servo drivers main circuit wire size.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"7\">\n<p>A.101\uff1a <br \/>Motor Overcurrent Detected <br \/>(The current to <br \/>the motor <br \/>exceeded the <br \/>allowable current.) <\/p>\n<\/td>\n<td>\n<p>The Main Circuit <br \/>Cable is not wired correctly or there is faulty contact.<\/p>\n<\/td>\n<td>\n<p>Check the wiring. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a short-circuit or ground fault in a <br \/>Main Circuit Cable. <\/p>\n<\/td>\n<td>\n<p>Check for short-circuits across cable phases U, V, and W, or between the ground and cable phases U, V, and W.<\/p>\n<\/td>\n<td>\n<p>The cable may be shortcircuited. Replace the <br \/>cable. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a short-circuit or ground fault inside the Servomotor. <\/p>\n<\/td>\n<td>\n<p>Check for short-circuits across Servomotor <br \/>phases U, V, and W, or between the ground <br \/>and Servomotor phases U, V, or W.<\/p>\n<\/td>\n<td>\n<p>The Servomotor may be <br \/>faulty. Replace the Servomotor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a short-circuit or ground fault inside the servo driver. <\/p>\n<\/td>\n<td>\n<p>Check for short-circuits across the Servomotor connection terminals U, V, and W on the <br \/>servo driver, or <br \/>between the ground <br \/>and terminals U, V, or W.<\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A heavy load was applied while the <br \/>Servomotor <br \/>was stopped <br \/>or running at a low speed.<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>operating conditions exceed Servo Drive specifications. <\/p>\n<\/td>\n<td>\n<p>Reduce the load applied to the Servomotor. Or, increase the operating speed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A malfunction was caused by noise. <\/p>\n<\/td>\n<td>\n<p>Improve the noise environment, e.g. by <br \/>improving the wiring or <br \/>installation conditions, <br \/>and check to see if the <br \/>alarm still occurs. <\/p>\n<\/td>\n<td>\n<p>Implement countermeasures <br \/>against noise, such <br \/>as correct wiring of the <br \/>FG. Use an FG wire size <br \/>equivalent to the servo driver\u2019s main circuit wire <br \/>size. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.300\uff1a <br \/>Re-generation Fault<\/p>\n<\/td>\n<td>\n<p>The regenerative resistor <br \/>capacity (Pn600) is set to a value other than &quot;0&quot;, and the regenerative resistor is not installed. <\/p>\n<\/td>\n<td>\n<p>Check to see if an <br \/>External Regenerative <br \/>Resistor is connected <br \/>and check the setting of Pn600. <\/p>\n<\/td>\n<td>\n<p>Connect an external regenerative resistor, or set Pn600 (regenerative resistor capacity) to 0 when the regenerative resistor is not needed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>No external regeneration resistor <\/p>\n<\/td>\n<td>\n<p>Check to see if an <br \/>External Regenerative <br \/>Resistor or a Regenerative Resistor Unit is connected and check the <br \/>setting of Pn600. <\/p>\n<\/td>\n<td>\n<p>After connecting the external regeneration resistor, set the appropriate value for Pn600.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The jumper wire of the <br \/>regenerative resistor <br \/>connection terminals B2-B3 is disconnected.<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>jumper is connected between power supply terminals B2 and B3.<\/p>\n<\/td>\n<td>\n<p>Correctly connect a <br \/>jumper. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The External Regenerative Resistor or <br \/>Regenerative Resistor <br \/>Unit is not wired <br \/>correctly, or was <br \/>removed or disconnected<\/p>\n<\/td>\n<td>\n<p>Check the wiring of the External Regenerative <br \/>Resistor or Regenerative Resistor Unit. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring of the External Regenerative <br \/>Resistor or Regenerative Resistor Unit. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>While the main circuit <br \/>power supply is OFF, turn the control power supply to the servo driver OFF <br \/>and ON again. If the alarm still occurs, the servo driver may be faulty. <\/p>\n<p>Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.320\uff1a <br \/>Regenerative Overload<\/p>\n<\/td>\n<td>\n<p>The power supply <br \/>voltage exceeded the specified range.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Set the power supply voltage within the specified <br \/>range.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"6\"><\/td>\n<td>\n<p>The external regenerative resistance value <br \/>or regenerative resistor capacity is too <br \/>small, or there has <br \/>been a continuous <br \/>regeneration state.<\/p>\n<\/td>\n<td>\n<p>Reconfirm operating conditions and capacity <\/p>\n<\/td>\n<td>\n<p>Change the regenerative resistor value and regenerative resistor capacity, and adjust the operating conditions again. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Continuously bear negative load and be in continuous regeneration state<\/p>\n<\/td>\n<td>\n<p>Check the load applied to the running servo motor. <\/p>\n<\/td>\n<td>\n<p>Reconsider the system including the servo, machine, and operating conditions. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn600 <br \/>(Regenerative Resistor Capacity) is <br \/>smaller than the <br \/>capacity of the External Regenerative <br \/>Resistor. <\/p>\n<\/td>\n<td>\n<p>Check to see if a <br \/>Regenerative Resistor is connected and check the setting of Pn600. <\/p>\n<\/td>\n<td>\n<p>Correct the setting of <br \/>Pn600. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn603 <br \/>(Regenerative Resistance) is smaller than <br \/>the capacity of the <br \/>External Regenerative <br \/>Resistor.<\/p>\n<\/td>\n<td>\n<p>Check to see if a <br \/>Regenerative Resistor is connected and check the setting of Pn603. <\/p>\n<\/td>\n<td>\n<p>Correct the setting of <br \/>Pn603. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The external regenerative resistance is too high <\/p>\n<\/td>\n<td>\n<p>Check the regenerative resistance. <\/p>\n<\/td>\n<td>\n<p>Change the regenerative resistance to a <br \/>correct value or use an External Regenerative Resistor of an appropriate capacity.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.330\uff1a <br \/>Main Circuit <br \/>Power Supply <br \/>Wiring Error <br \/>(Detected when the main circuit power supply is turned ON.) <\/p>\n<\/td>\n<td>\n<p>The regenerative resistor <br \/>was disconnected when the servo driver power supply voltage was high. <\/p>\n<\/td>\n<td>\n<p>Measure the resistance of the regenerative resistor using a measuring instrument. <\/p>\n<\/td>\n<td>\n<p>If you are using the regenerative resistor built into the servo driver, replace the servo driver. <\/p>\n<p>If you are using an External Regenerative Resistor, replace the External Regenerative Resistor.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DC power was supplied when an AC power supply input was specified in the settings <\/p>\n<\/td>\n<td>\n<p>Check the power supply to see if it is a DC <br \/>power supply. <\/p>\n<\/td>\n<td>\n<p>Correct the power supply setting to match the <br \/>actual power supply. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AC power was supplied when a DC <br \/>power supply input <br \/>was specified in the <br \/>settings.<\/p>\n<\/td>\n<td>\n<p>Check the power supply to see if it is an AC <br \/>power supply. <\/p>\n<\/td>\n<td>\n<p>Correct the power supply setting to match the <br \/>actual power supply. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The regenerative resistor <br \/>capacity (Pn600) is set to a value other than &quot;0&quot; and the regenerative resistor is not installed.<\/p>\n<\/td>\n<td>\n<p>Check to see if an External <br \/>Regenerative Resistor is connected and check the setting of Pn600. <\/p>\n<\/td>\n<td>\n<p>Connect an External <br \/>Regenerative Resistor, or if an External Regenerative Resistor is not <br \/>required, set Pn600 to 0.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>A.400\uff1a <br \/>Overvoltage <br \/>(Detected in the main circuit <br \/>power supply <br \/>section of the <br \/>servo driver.) <\/p>\n<\/td>\n<td>\n<p>The power supply <br \/>voltage exceeded the specified range. <\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Set the AC\/DC power <br \/>supply voltage within the specified range. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power supply is <br \/>not stable or was <br \/>influenced by a lightning surge. <\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Improve the power supply <br \/>conditions, install a <br \/>surge absorber, and then <br \/>turn the power supply <br \/>OFF and ON again. If the <br \/>alarm still occurs, the <br \/>servo driver may be <br \/>faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The voltage for AC <br \/>power supply was too high during acceleration or deceleration.<\/p>\n<\/td>\n<td>\n<p>Check the power supply voltage and the <br \/>speed and torque <br \/>during operation.<\/p>\n<\/td>\n<td>\n<p>Set the AC power supply voltage within the specified range. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The external regenerative resistance is too <br \/>high for the operating <br \/>conditions.<\/p>\n<\/td>\n<td>\n<p>Check the operating <br \/>conditions and the <br \/>regenerative resistance. <\/p>\n<\/td>\n<td>\n<p>Confirm that the moment of inertia ratio or mass ratio is within the <br \/>allowable range\u3002 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The moment of inertia ratio or mass ratio <br \/>exceeded the allowable value.<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>moment of inertia ratio or mass ratio is within the allowable range.<\/p>\n<\/td>\n<td>\n<p>Increase the deceleration time, or reduce the load. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in<\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<td>\n<p>While the main circuit<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>the servo driver. <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>power supply is OFF, turn the control power supply to the servo driver OFF <br \/>and ON again. If the alarm still occurs, the servo driver may be faulty. <\/p>\n<p>Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.410\uff1a <br \/>Undervoltage <br \/>(Detected in the main circuit <br \/>power supply <br \/>section of the <br \/>servo driver.) <\/p>\n<\/td>\n<td>\n<p>The power supply voltage went below the specified range.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage.<\/p>\n<\/td>\n<td>\n<p>Set the power supply voltage within the specified <br \/>range.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power supply voltage dropped <br \/>during operation.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Increase the power supply capacity. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A momentary power interruption occurred. <\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>If you have changed the <br \/>setting of Pn509 (Momentary Power Interruption <br \/>Hold Time), decrease the <br \/>setting.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The servo driver fuse is blown out. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the <br \/>servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>A.510\uff1a <br \/>Overspeed <br \/>(The motor <br \/>exceeded the <br \/>maximum speed.) <\/p>\n<\/td>\n<td>\n<p>The order of phases U, V, and W in the motor wiring is not correct.<\/p>\n<\/td>\n<td>\n<p>Check the wiring of the Servomotor. <\/p>\n<\/td>\n<td>\n<p>Make sure that the Servomotor is correctly wired. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A reference value that <br \/>exceeded the overspeed detection level <br \/>was input. <\/p>\n<\/td>\n<td>\n<p>Check the input reference. <\/p>\n<\/td>\n<td>\n<p>Reduce the reference <br \/>value. Or, adjust the gain. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The motor exceeded the maximum speed. <\/p>\n<\/td>\n<td>\n<p>Check the waveform of the motor speed. <\/p>\n<\/td>\n<td>\n<p>Reduce the speed reference input gain and <br \/>adjust the servo gain. Or, <br \/>reconsider the operating <br \/>conditions.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.520\uff1a <br \/>Vibration Alarm <\/p>\n<\/td>\n<td>\n<p>Abnormal oscillation was detected in the motor speed. <\/p>\n<\/td>\n<td>\n<p>Check for abnormal motor noise, and check the speed and torque waveforms during operation. <\/p>\n<\/td>\n<td>\n<p>Reduce the motor speed. Or, reduce the setting of Pn100 (Speed Loop <br \/>Gain). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn103 (Moment of Inertia <br \/>Ratio) is greater than the actual moment of inertia or was greatly changed.<\/p>\n<\/td>\n<td>\n<p>Check the moment of inertia ratio or mass ratio. <\/p>\n<\/td>\n<td>\n<p>Set Pn103 (Moment of <br \/>Inertia Ratio) to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The vibration detection level (Pn312 or <br \/>Pn384) is not suitable. <\/p>\n<\/td>\n<td>\n<p>Check that the vibration detection level <br \/>(Pn312 or Pn384) is <br \/>suitable.<\/p>\n<\/td>\n<td>\n<p>Set a suitable vibration detection level (Pn312 or Pn384). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.521\uff1a <br \/>Autotuning Alarm (Vibration was <br \/>detected while <br \/>executing the <br \/>custom tuning, <br \/>Easy FFT, or the <br \/>tuning-less <br \/>function.) <\/p>\n<\/td>\n<td>\n<p>The Servomotor <br \/>vibrated considerably while performing the tuning-less function. <\/p>\n<\/td>\n<td>\n<p>Check the waveform of the motor speed. <\/p>\n<\/td>\n<td>\n<p>Reduce the load so that <br \/>the moment of inertia ratio is within the allowable <br \/>value. Or increase the <br \/>load level or reduce the <br \/>rigidity level in the tuningless level settings.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Servomotor <br \/>vibrated considerably <br \/>while performing custom tuning or Easy <br \/>FFT. <\/p>\n<\/td>\n<td>\n<p>Check the waveform of the motor speed. <\/p>\n<\/td>\n<td>\n<p>Check the operating procedure of corresponding <br \/>function and implement <br \/>corrections. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.710\uff1a <br \/>Instantaneous Overload <br \/>A.720\uff1a <br \/>Continuous <br \/>Overload <\/p>\n<\/td>\n<td>\n<p>The wiring is not correct or there is a faulty <br \/>connection in the <br \/>motor or encoder wiring.<\/p>\n<\/td>\n<td>\n<p>Check the wiring. <\/p>\n<\/td>\n<td>\n<p>Make sure that the Servomotor and encoder are <br \/>correctly wired. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operation was performed that exceeded <br \/>the overload protection characteristics. <\/p>\n<\/td>\n<td>\n<p>Check the motor overload characteristics and <br \/>Run command. <\/p>\n<\/td>\n<td>\n<p>Reconsider the load and operating conditions. Or, increase the motor <br \/>capacity. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An excessive load was <br \/>applied during operation <\/p>\n<\/td>\n<td>\n<p>Check the operation reference and motor <\/p>\n<\/td>\n<td>\n<p>Correct the mechanical problem. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>because the Servomotor was not driven due to <br \/>mechanical problems. <\/p>\n<\/td>\n<td>\n<p>speed. <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.730\uff1a <br \/>A.731\uff1a <br \/>Dynamic Brake <br \/>Overload (An <br \/>excessive power <br \/>consumption by the dynamic brake was detected.) <\/p>\n<\/td>\n<td>\n<p>The Servomotor was rotated by an external force. <\/p>\n<\/td>\n<td>\n<p>Check the operation status. <\/p>\n<\/td>\n<td>\n<p>Implement measures to ensure that the motor will not be rotated by an <br \/>external force.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>When the Servomotor was stopped with the dynamic brake, the rotational or linear kinetic energy exceeded the capacity of the dynamic <br \/>brake resistor. <\/p>\n<\/td>\n<td>\n<p>Check the power consumed by the DB resistor <br \/>to see how <br \/>frequently the DB is <br \/>being used. <\/p>\n<\/td>\n<td>\n<p>Reconsider the following: \u2022 Reduce the Servomotor command speed. <\/p>\n<p>\u2022 Decrease the moment of inertia ratio or mass ratio. <\/p>\n<p>\u2022 Reduce the frequency of stopping with the <br \/>dynamic brake.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.740\uff1a <br \/>Inrush Current <br \/>Limiting Resistor Overload <br \/>(The main circuit power supply <br \/>was frequently <br \/>turned ON and OFF.) <\/p>\n<\/td>\n<td>\n<p>The allowable frequency of the inrush <br \/>current limiting resistor was exceeded <br \/>when the main circuit <br \/>power supply was <br \/>turned ON and OFF. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Reduce the frequency of turning the main circuit power supply ON and OFF. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>A.810\uff1a <br \/>Encoder Backup Alarm <br \/>(Detected at the encoder, but only when an absolute encoder is <br \/>used.) <\/p>\n<\/td>\n<td>\n<p>Encoder type <br \/>Pn002:n.\u25afX\u25af\u25afis not set<\/p>\n<\/td>\n<td>\n<p>Confirm power supply and parameter settings.<\/p>\n<\/td>\n<td>\n<p>Incremental type: \u25af1\u25af\u25af<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power to the absolute encoder was turned ON for the first time. <\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>power supply was <br \/>turned ON for the first time. <\/p>\n<\/td>\n<td>\n<p>Set up the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Encoder Cable was disconnected and then connected <br \/>again.<\/p>\n<\/td>\n<td>\n<p>Check to see if the <br \/>power supply was <br \/>turned ON for the first time.<\/p>\n<\/td>\n<td>\n<p>Check the encoder connection and set up the <br \/>encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Power is not being <br \/>supplied both from <br \/>the control power <br \/>supply (+5 V) from the servo driver and <br \/>from the battery <br \/>power supply. <\/p>\n<\/td>\n<td>\n<p>Check the encoder <br \/>connector battery and the connector status. <\/p>\n<\/td>\n<td>\n<p>Replace the battery or <br \/>implement similar measures to supply power to <br \/>the encoder, and set up <br \/>the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the absolute encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>If the alarm still occurs after setting up the <br \/>encoder again, replace the Servomotor.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.820\uff1a <br \/>Encoder Checksum Alarm <br \/>(Detected at the <br \/>encoder.) <\/p>\n<\/td>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>When Using an Absolute <br \/>Encoder Set up the encoder again. <\/p>\n<p>If the alarm still occurs, the Servomotor may be faulty. Replace the Servomotor. <\/p>\n<p>When Using a Singleturn Absolute Encoder or Incremental Encoder <br \/>\u2022 The Servomotor may be <br \/>faulty. Replace the Servomotor. <\/p>\n<p>\u2022 The linear encoder may be faulty. Replace the <br \/>linear encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.830\uff1a <br \/>Encoder Battery <br \/>Alarm <br \/>(The absolute <br \/>encoder battery <br \/>voltage was lower than the specified level.) <\/p>\n<\/td>\n<td>\n<p>The battery connection is faulty or a battery is not connected.<\/p>\n<\/td>\n<td>\n<p>Check the battery connection. <\/p>\n<\/td>\n<td>\n<p>Correct the battery connection. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The battery voltage is lower than the specified value (2.7 V).<\/p>\n<\/td>\n<td>\n<p>Measure the battery voltage. <\/p>\n<\/td>\n<td>\n<p>Replace the battery. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.840\uff1a <br \/>Encoder Data <\/p>\n<\/td>\n<td>\n<p>The encoder malfunctioned.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Alarm <br \/>(Detected at the encoder.) <\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The encoder malfunctioned due to noise. <\/p>\n<\/td>\n<td>\n<p>&#8211;<\/p>\n<\/td>\n<td>\n<p>Correct the wiring around the encoder by separating the Encoder Cable from <br \/>the Servomotor Main Circuit Cable or by grounding <br \/>the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.850\uff1a <br \/>Encoder Overspeed (Detected at the <br \/>encoder when <br \/>the control power supply is turned <br \/>ON.) <\/p>\n<\/td>\n<td>\n<p>Rotary Servomotor: The Servomotor <br \/>speed was 200 min-1 or higher when the control power supply was turned ON. <\/p>\n<\/td>\n<td>\n<p>Check the motor speed when the power supply is turned ON. <\/p>\n<\/td>\n<td>\n<p>Reduce the Servomotor speed to a value less than 200 min-1, and turn ON the control power supply. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to <br \/>the servo driver OFF and <br \/>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.C10\uff1a <br \/>Servomotor Out of Control <br \/>(Detected when the servo is <br \/>turned ON.) <\/p>\n<\/td>\n<td>\n<p>The order of phases U, V, and W in the motor wiring is not correct.<\/p>\n<\/td>\n<td>\n<p>Check the Servomotor wiring. <\/p>\n<\/td>\n<td>\n<p>Make sure that the Servomotor is correctly wired. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>If the motor wiring is correct and the alarm still <br \/>occurs after turning the <br \/>power supply OFF and <br \/>ON again, the Servomotor <br \/>or linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.C20\uff1a <br \/>Phase Detection Error <\/p>\n<\/td>\n<td>\n<p>The linear encoder <br \/>signal level is too low. <\/p>\n<\/td>\n<td>\n<p>Check the voltage of the linear encoder. <\/p>\n<\/td>\n<td>\n<p>Fine-tune the mounting of the scale head. Or, replace the linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The count-up direction of the linear <br \/>encoder does not <br \/>match the forward <br \/>direction of the Moving Coil in the motor. <\/p>\n<\/td>\n<td>\n<p>Check the setting of <br \/>Pn080 = n.\u25af\u25afX \u25af <br \/>(Motor Phase Sequence Selection). Check the <br \/>installation orientation for the linear encoder and Moving Coil.<\/p>\n<\/td>\n<td>\n<p>Change the setting of <br \/>Pn080 = n.\u25af\u25afX \u25af. <\/p>\n<p>Correctly reinstall the linear encoder or Moving Coil. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The polarity sensor signal is being <br \/>affected by noise. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Correct the FG wiring. <\/p>\n<p>Implement countermeasures against noise for the <br \/>polarity sensor wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>A.C21\uff1a <br \/>Polarity Sensor Error <\/p>\n<\/td>\n<td>\n<p>Linear encoder pitch (Pn282) setting value is wrong <\/p>\n<\/td>\n<td>\n<p>Confirm the linear encoder pitch (Pn282). <\/p>\n<\/td>\n<td>\n<p>Confirm the linear encoder specifications and set the values correctly. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The polarity sensor is <br \/>protruding from the <br \/>Magnetic Way of the motor.<\/p>\n<\/td>\n<td>\n<p>Check the polarity sensor. <\/p>\n<\/td>\n<td>\n<p>Correctly reinstall the <br \/>Moving Coil or Magnetic Way of the motor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The polarity sensor is not wired correctly. <\/p>\n<\/td>\n<td>\n<p>Check the wiring of the polarity sensor. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring of the polarity sensor <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The polarity sensor failed.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Replace the polarity sensor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C22\uff1a <br \/>Phase Information Disagreement <\/p>\n<\/td>\n<td>\n<p>The servo driver <br \/>phase information is <br \/>different from the linear encoder phase <br \/>information.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Perform polarity detection. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"4\">\n<p>A.C50\uff1a <br \/>Polarity Detection Failure <\/p>\n<\/td>\n<td>\n<p>The parameter settings are not correct. <\/p>\n<\/td>\n<td>\n<p>Check the linear encoder specifications <br \/>and feedback signal <br \/>status. <\/p>\n<\/td>\n<td>\n<p>The settings of Pn282 <br \/>(Linear Encoder Scale <br \/>Pitch) and Pn080 = <br \/>n.\u25af\u25afX \u25af (Motor Phase Sequence Selection) may not match the installation. <\/p>\n<p>Set the parameters <br \/>to correct values.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is noise on the scale signal. <\/p>\n<\/td>\n<td>\n<p>Check to make sure <br \/>that the frame grounds <br \/>of the Serial Converter <br \/>Unit and Servomotor <br \/>are connected to the <br \/>FG terminal on the servo driver and that the <br \/>FG terminal on the servo driver is connected <br \/>to the frame ground on <br \/>the power supply. <\/p>\n<p>And, confirm that the <br \/>shield is properly processed on the Linear <br \/>Encoder Cable. Check <br \/>to see if the detection <br \/>reference is repeatedly <br \/>output in one direction. <\/p>\n<\/td>\n<td>\n<p>Implement appropriate countermeasures against noise for the Linear <br \/>Encoder Cable. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An external force was applied to the Moving Coil of the motor. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The polarity cannot be properly detected if the detection reference is 0 and the speed feedback is not 0 because of an external <br \/>force, such as cable tension, applied to the Moving Coil. Implement measures to reduce the external force so that the speed feedback goes to 0. If the external force cannot be reduced, increase the setting of Pn481 <br \/>(Polarity Detection Speed Loop Gain). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The linear encoder resolution is too low. <\/p>\n<\/td>\n<td>\n<p>Check the linear <br \/>encoder scale pitch to see if it is within 100 <br \/>\u03bcm. <\/p>\n<\/td>\n<td>\n<p>If the linear encoder scale <br \/>pitch is 100 \u03bcm or higher, <br \/>the servo driver cannot <br \/>detect the correct speed <br \/>feedback. Use a linear <br \/>encoder scale pitch with <br \/>higher resolution. (We recommend a pitch of 40 \u03bcm <br \/>or less.) Or, increase the <br \/>setting of Pn485 (Polarity <br \/>Detection Reference <br \/>Speed). However, <br \/>increasing the setting of <br \/>Pn485 will increase the <br \/>Servomotor movement <br \/>range that is required for <br \/>polarity detection. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C51\uff1a <br \/>Overtravel <br \/>Detected during Polarity Detection <\/p>\n<\/td>\n<td>\n<p>The overtravel signal was detected during polarity detection. <\/p>\n<\/td>\n<td>\n<p>Check the overtravel position. <\/p>\n<\/td>\n<td>\n<p>Wire the overtravel signals. <\/p>\n<p>Execute polarity <br \/>detection at a position <br \/>where an overtravel signal would not be <br \/>detected. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C52\uff1a <br \/>Polarity Detection Not Completed <\/p>\n<\/td>\n<td>\n<p>The servo was turned ON under the following circumstances. <\/p>\n<p>\u2022 Before polarity <br \/>detection was completed \u2022 Before \/P-DET was <br \/>input<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Input the \/P-DET signal. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C53\uff1a <br \/>Out of Range of <br \/>Motion for Polarity Detection <\/p>\n<\/td>\n<td>\n<p>The travel distance <br \/>exceeded the setting <br \/>of Pn48E (Polarity <br \/>Detection Range) in <br \/>the middle of detection.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Increase the setting of <br \/>Pn48E (Polarity Detection Range). Or, increase the <br \/>setting of Pn481 (Polarity <br \/>Detection Speed Loop Gain).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.C54\uff1a <br \/>Polarity Detection Failure 2 <\/p>\n<\/td>\n<td>\n<p>An external force was <br \/>applied to the Servomotor.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Increase the setting of <br \/>Pn495 (Polarity Detection <br \/>Confirmation Force Reference). <\/p>\n<p>Increase the setting <br \/>of Pn498 (Polarity Detection<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>Allowable Error <br \/>Range). Increasing the <br \/>allowable error will also <br \/>increase the motor temperature.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.C80\uff1a <br \/>Encoder Clear <br \/>Error or Multiturn Limit Setting Error <\/p>\n<\/td>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to <br \/>the servo driver OFF and <br \/>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.C90\uff1a <br \/>Encoder <br \/>Communications Error <\/p>\n<\/td>\n<td>\n<p>There is a faulty contact in the connector <br \/>or the connector is <br \/>not wired correctly for the encoder. <\/p>\n<\/td>\n<td>\n<p>Check the condition of the encoder connector. <\/p>\n<\/td>\n<td>\n<p>Reconnect the encoder connector and check the encoder wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a cable disconnection <br \/>or shortcircuit <br \/>in the encoder. <\/p>\n<p>Or, the cable impedance is outside the <br \/>specified values.<\/p>\n<\/td>\n<td>\n<p>Check the condition of the Encoder Cable. <\/p>\n<\/td>\n<td>\n<p>Use the Encoder Cable <br \/>within the specified specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>One of the following <br \/>has occurred: corrosion <br \/>caused by <br \/>improper temperature, <br \/>humidity, or gas, <br \/>a short-circuit caused <br \/>by entry of water <br \/>drops or cutting oil, or <br \/>faulty contact in connector caused by <br \/>vibration.<\/p>\n<\/td>\n<td>\n<p>Check the operating environment. <\/p>\n<\/td>\n<td>\n<p>Improve the operating <br \/>environment, and replace <br \/>the cable. If the alarm still <br \/>occurs, replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A malfunction was caused by noise. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Correct the wiring around the encoder by separating the Encoder Cable from <br \/>the Servomotor Main Circuit Cable or by grounding <br \/>the encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Connect the Servomotor to another servo driver, <br \/>and turn ON the control power supply. If no alarm occurs, the servo driver <br \/>may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.C91\uff1a <br \/>Encoder <br \/>Communications Position <br \/>Data <br \/>Acceleration Rate Error <\/p>\n<\/td>\n<td>\n<p>Noise entered on the signal lines because the Encoder Cable is bent or the sheath is damaged.<\/p>\n<\/td>\n<td>\n<p>Check the condition of the Encoder Cable and connectors. <\/p>\n<\/td>\n<td>\n<p>Check the Encoder Cable <br \/>to see if it is installed correctly. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Encoder Cable is <br \/>bundled with a highcurrent line or installed near a <br \/>highcurrent line.<\/p>\n<\/td>\n<td>\n<p>Check the installation condition of the Encoder Cable. <\/p>\n<\/td>\n<td>\n<p>Confirm that there is no surge voltage on the Encoder Cable. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is variation in <br \/>the FG potential <br \/>because of the influence of machines on <br \/>the Servomotor side, <br \/>such as a welder.<\/p>\n<\/td>\n<td>\n<p>Check the installation condition of the <br \/>Encoder Cable. <\/p>\n<\/td>\n<td>\n<p>Properly ground the <br \/>machine to separate it <br \/>from the FG of the <br \/>encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.C92\uff1a <br \/>Encoder <br \/>Communications Timer <br \/>Error <\/p>\n<\/td>\n<td>\n<p>Noise entered on the signal line from the encoder.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Implement countermeasures against noise for the <br \/>encoder wiring.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Excessive vibration or shock was applied to the encoder.<\/p>\n<\/td>\n<td>\n<p>Check the operating conditions. <\/p>\n<\/td>\n<td>\n<p>Reduce machine vibration. <\/p>\n<p>Correctly install the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>A failure occurred in the encoder.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Turn the power supply to <br \/>the servo driver OFF and <br \/>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.CA0\uff1a <br \/>Encoder Parameter Error <\/p>\n<\/td>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to <br \/>the servo driver OFF and <br \/>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p>A.Cb0\uff1a <br \/>Encoder Echoback Error <\/p>\n<\/td>\n<td>\n<p>The encoder is wired incorrectly or there is faulty contact. <\/p>\n<\/td>\n<td>\n<p>Check the wiring of the encoder. <\/p>\n<\/td>\n<td>\n<p>Make sure that the <br \/>encoder is correctly <br \/>wired. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The specifications of the Encoder Cable are not correct and noise entered on it. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Use a shielded twistedpair wire cable or a <br \/>screened twisted-pair <br \/>cable with conductors of at least 0.12 mm2. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Encoder Cable is too long and noise <br \/>entered on it. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>\u2022 Rotary Servomotors: <br \/>The Encoder Cable wiring distance must be 50 <br \/>m max. <\/p>\n<p>\u2022 Linear Servomotors: <br \/>The Encoder Cable wiring distance must be 20 <br \/>m max.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is variation in <br \/>the FG potential <br \/>because of the influence of machines on <br \/>the Servomotor side, <br \/>such as a welder. <\/p>\n<\/td>\n<td>\n<p>Check the condition of the Encoder Cable and connectors. <\/p>\n<\/td>\n<td>\n<p>Properly ground the <br \/>machine to separate it <br \/>from the FG of the <br \/>encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Excessive vibration or shock was applied to the encoder. <\/p>\n<\/td>\n<td>\n<p>Check the operating conditions. <\/p>\n<\/td>\n<td>\n<p>Reduce machine vibration. <\/p>\n<p>Correctly install the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to <br \/>the servo driver OFF and <br \/>ON again. If the alarm still <br \/>occurs, the Servomotor or <br \/>linear encoder may be <br \/>faulty. Replace the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>A.d00\uff1a <br \/>Position Deviation Overflow <br \/>(The setting of <br \/>Pn520 (Position <br \/>Deviation Overflow Alarm Level) <br \/>was exceeded by the position <br \/>deviation <br \/>while the <br \/>servo was ON.) <\/p>\n<\/td>\n<td>\n<p>The Servomotor U, V, and W wiring is not correct. <\/p>\n<\/td>\n<td>\n<p>Check the wiring of the <br \/>Servomotor\u2019s Main Circuit Cables. <\/p>\n<\/td>\n<td>\n<p>Make sure that there are no faulty contacts in the wiring for the Servomotor and encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The acceleration of <br \/>the position reference is too high.<\/p>\n<\/td>\n<td>\n<p>Reduce the reference <br \/>acceleration and try <br \/>operating the servo driver.<\/p>\n<\/td>\n<td>\n<p>Reduce the &quot;position command&quot; speed or command acceleration, or adjust the <br \/>electronic gear ratio.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn520 (Position Deviation <br \/>Overflow Alarm Level) is too low for the <br \/>operating conditions.<\/p>\n<\/td>\n<td>\n<p>Check Pn520 (Position Deviation Overflow <br \/>Alarm Level) to see if it is set to an appropriate value.<\/p>\n<\/td>\n<td>\n<p>Optimize the setting of Pn520. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d01\uff1a <br \/>Position Deviation Overflow <br \/>Alarm at Servo <br \/>ON<\/p>\n<\/td>\n<td>\n<p>The servo was turned ON after the position deviation exceeded the setting of Pn526 (Position Deviation<\/p>\n<\/td>\n<td>\n<p>Check the position deviation while the servo is OFF. <\/p>\n<\/td>\n<td>\n<p>Set the position deviation to be cleared while the servo is OFF. <\/p>\n<p>Optimize the setting of Pn526 (Position Deviation<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>Overflow Alarm Level at Servo ON) while the servo was OFF. <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Overflow Alarm Level at Servo ON). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d02\uff1a <br \/>Position Deviation Overflow <br \/>Alarm for Speed Limit at Servo ON <\/p>\n<\/td>\n<td>\n<p>When the servo is turned on in the position deviation <br \/>accumulation state, the <br \/>speed limit is implemented by the speed limit value <br \/>(Pn529) when the servo is turned on. In this state, the &quot;position command&quot; is input and exceeds the set value of the excessive position <br \/>deviation error alarm value (Pn520).<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Set the correct excessive position deviation error alarm value (Pn520). <\/p>\n<p>Or set the speed limit value (Pn529) when the servo is on to the correct value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>A.d10\uff1a <br \/>Motor-Load Position Deviation <br \/>Overflow <\/p>\n<\/td>\n<td>\n<p>The motor direction <br \/>and external encoder installation orientation are backward. <\/p>\n<\/td>\n<td>\n<p>Check the motor direction <br \/>and the external <br \/>encoder installation orientation. <\/p>\n<\/td>\n<td>\n<p>Install the external <br \/>encoder in the opposite direction, or change the setting of Pn002 = <br \/>n.X \u25af\u25af\u25af (External <br \/>Encoder Usage) to <br \/>reverse the direction.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is an error in the connection between <br \/>the load (e.g., stage) <br \/>and external encoder coupling.<\/p>\n<\/td>\n<td>\n<p>Check the coupling of the external encoder. <\/p>\n<\/td>\n<td>\n<p>Check the mechanical <br \/>coupling. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>FA.d30 <br \/>Position Data Overflow<\/p>\n<\/td>\n<td>\n<p>The position data exceeded <br \/>\u00b11,879,048,192.<\/p>\n<\/td>\n<td>\n<p>Check the input reference pulse counter. <\/p>\n<\/td>\n<td>\n<p>Reconsider the operating specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>A.F10\uff1a <br \/>Power Supply <br \/>Line Open Phase (The voltage was low for more than one second for <br \/>phase R, S, or T <br \/>when the main <br \/>power supply <br \/>was ON.) <\/p>\n<\/td>\n<td>\n<p>A single-phase power <br \/>supply was input without specifying a single- <br \/>phase AC power <br \/>supply input (Pn00B = <br \/>n.\u25af1 \u25af\u25af). <\/p>\n<\/td>\n<td>\n<p>Check the power supply and the parameter <br \/>setting. <\/p>\n<\/td>\n<td>\n<p>Set the correct power input and parameters. (Pn00B=n.1) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The three-phase <br \/>power supply wiring is not correct. <\/p>\n<\/td>\n<td>\n<p>Check the power supply wiring. <\/p>\n<\/td>\n<td>\n<p>Make sure that the power supply is correctly wired. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The three-phase power supply is unbalanced.<\/p>\n<\/td>\n<td>\n<p>Measure the voltage for each phase of the <br \/>three-phase power supply.<\/p>\n<\/td>\n<td>\n<p>Balance the power supply by changing phases. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Poor wiring or bad <br \/>connections in the motor wiring<\/p>\n<\/td>\n<td>\n<p>Confirm the wiring. <\/p>\n<\/td>\n<td>\n<p>Check if there is any problem with the motor wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\"><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*1. Detection Conditions <br \/>Rotary Servomotor <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"4\">\n<p>If either of the following conditions is detected, an alarm will occur. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>\u2022 Pn533[min-1 (RPM)]\u00d7 \ud835\udc38\ud835\udc5b\ud835\udc50\ud835\udc5c\ud835\udc51\ud835\udc52\ud835\udc5f \ud835\udc5f\ud835\udc52\ud835\udc60\ud835\udc5c\ud835\udc59\ud835\udc62\ud835\udc61\ud835\udc56\ud835\udc5c\ud835\udc5b\t6\u00d7105<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>\u2264<\/p>\n<\/td>\n<td>\n<p>Pn20E<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Pn20E<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn210<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\">\n<p>\tEncoder resolution\u2022 Maximum motor speed [min-1 (RPM)]\u00d7Approx.3.66\u00d71012\u2264<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn210<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*2. Detection Conditions <\/p>\n<p>\u2022 Rotary Servomotor <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"4\">\n<p>If either of the following conditions is detected, an alarm will occur. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>\t\t 1 \u2022 Rated motor speed [min-1 (RPM)]\u00d7 3 \u00d7 <\/p>\n<\/td>\n<td>\n<p>Encoder resolution<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Pn20E<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6\u00d7105<\/p>\n<\/td>\n<td><\/td>\n<td rowspan=\"2\">\n<p>Pn210 <br \/>Pn20E<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\">\n<p>\tEncoder resolution\u2022 Maximum motor speed [min-1 (RPM)]\u00d7Approx.3.66\u00d71012\u2265<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn210<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>9.2.3 Resetting Alarms <\/h4>\n<p>If there is an ALM (Servo Alarm) signal, use one of the following methods to reset the alarm after eliminating the cause of the alarm. <\/p>\n<p>The \/ALM-RST (Alarm Reset) signal will not always reset encoder-related alarms. If you cannot reset an alarm with the \/ALM-RST signal, turn OFF the control power supply to reset it. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-09\/sc3-sc3man-en-09-007.png\" \/><\/p>\n<\/td>\n<td>\n<p>Be sure to eliminate the cause of an alarm before you reset the alarm. <\/p>\n<p>If you reset the alarm and continue operation without eliminating the cause of the alarm, it may result in damage to the equipment or fire. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022 Reset based on false alarm, warning clear (ALM_CLR) signal <br \/>\u2022 Based on the panel operation buttons, press the S button to reset <\/p>\n<h4>9.2.4 Displaying the Alarm History <\/h4>\n<p>The alarm history displays up to the last ten alarms that have occurred in the servo driver. <\/p>\n<p>9.2.5 Clearing the Alarm History <br \/>\tYou can clear the alarm history that is recorded in the servo driver. <\/p>\n<p>The alarm history is not cleared when alarms are reset or when the servo driver main circuit power is turned OFF. <\/p>\n<p>You must perform the following procedure. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Distribute <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td>\n<p>Fn006 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ProTuner <\/p>\n<\/td>\n<td>\n<p>[Alarm display]&#8212; [Alarm History]&#8212; [Clear] <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.3 Warning Displays <\/h3>\n<p>If a warning occurs in the servo driver, a warning number will be displayed on the panel display. Warnings are displayed to warn you before an alarm occurs. <\/p>\n<p>This section provides a list of warnings and the causes of and corrections for warnings. <\/p>\n<h4>9.3.1 List of Warnings <\/h4>\n<p>The list of warnings gives the warning name, warning meaning. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Warning Number <\/p>\n<\/td>\n<td>\n<p>Warning Name <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>Alarm <br \/>Reset <br \/>Possible<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.900 <\/p>\n<\/td>\n<td>\n<p>Position Deviation Overflow <\/p>\n<\/td>\n<td>\n<p>The position deviation exceeded the percentage set with the following formula: <br \/>(Pn520 \u00d7 Pn51E\/100) <\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.901 <\/p>\n<\/td>\n<td>\n<p>Position Deviation Overflow Alarm at Servo ON <\/p>\n<\/td>\n<td>\n<p>The position deviation when the servo was turned ON exceeded the percentage set with the following formula: (Pn526 \u00d7 Pn528\/100) <\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.910 <\/p>\n<\/td>\n<td>\n<p>Overload <\/p>\n<\/td>\n<td>\n<p>This warning occurs before an overload alarm (A.710 or A.720) occurs. If the warning is ignored and operation is continued, an alarm may occur.<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.911 <\/p>\n<\/td>\n<td>\n<p>Vibration <\/p>\n<\/td>\n<td>\n<p>Abnormal vibration was detected during motor operation. The detection level is the same as <br \/>A.520. Set whether to output an alarm or a warning by setting Pn310 (Vibration Detection Selection).<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.920 <\/p>\n<\/td>\n<td>\n<p>Regenerative Overload <\/p>\n<\/td>\n<td>\n<p>This warning occurs before an A.320 alarm <br \/>(Regenerative Overload) occurs. If the warning is ignored and operation is continued, an alarm may occur.<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.921 <\/p>\n<\/td>\n<td>\n<p>Dynamic Brake Overload<\/p>\n<\/td>\n<td>\n<p>This warning occurs before an A.731 alarm <br \/>(Dynamic Brake Overload) occurs. If the warning is<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>\n<p>ignored and operation is continued, an alarm may occur.<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.930 <\/p>\n<\/td>\n<td>\n<p>Absolute Encoder Battery Error<\/p>\n<\/td>\n<td>\n<p>This warning occurs when the voltage of absolute encoder\u2019s battery is low.<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.941 <\/p>\n<\/td>\n<td>\n<p>Change of Parameters Requires Restart<\/p>\n<\/td>\n<td>\n<p>Parameters have been changed that require the power supply to be turned OFF and ON again.<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.94A <\/p>\n<\/td>\n<td>\n<p>Data setting warning 1 (parameter number)<\/p>\n<\/td>\n<td>\n<p>The parameter number of the data setting warning 1 (parameter number) command is incorrect.<\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.94B <\/p>\n<\/td>\n<td>\n<p>Data setting warning 2 (out of data range)<\/p>\n<\/td>\n<td>\n<p>A value outside the range is set in the command data. <\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.94C <\/p>\n<\/td>\n<td>\n<p>Data setting warning 3 (calculation error)<\/p>\n<\/td>\n<td>\n<p>A calculation error was detected. <\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.94D <\/p>\n<\/td>\n<td>\n<p>Data setting warning 4 (parameter size)<\/p>\n<\/td>\n<td>\n<p>A data size discrepancy was detected. <\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.94E <\/p>\n<\/td>\n<td>\n<p>Data setting warning 5 (capture exception)<\/p>\n<\/td>\n<td>\n<p>A capture mode exception was detected. <\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.95A <\/p>\n<\/td>\n<td>\n<p>Command warning 1 (outside command conditions)<\/p>\n<\/td>\n<td>\n<p>The instruction was given when the conditions for the instruction were insufficient. <\/p>\n<\/td>\n<td>\n<p>automatic reset* <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.95B <\/p>\n<\/td>\n<td>\n<p>Command warning 2 <br \/>(unsupported command)<\/p>\n<\/td>\n<td>\n<p>Unsupported command entered. <\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.95D <\/p>\n<\/td>\n<td>\n<p>Command warning 4 (command interference)<\/p>\n<\/td>\n<td>\n<p>Interference of instructions (mainly refers to interference of capture instructions).<\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.95E <\/p>\n<\/td>\n<td>\n<p>Command warning 5 (subcommands cannot be used)<\/p>\n<\/td>\n<td>\n<p>The subcommand conflicts with the main command. <\/p>\n<\/td>\n<td>\n<p>automatic reset* <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Warning Number <\/p>\n<\/td>\n<td>\n<p>Warning Name <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>Alarm <br \/>Reset <br \/>Possible<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.95F <\/p>\n<\/td>\n<td>\n<p>Command warning 6 (undefined command)<\/p>\n<\/td>\n<td>\n<p>Undefined command entered. <\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.971 <\/p>\n<\/td>\n<td>\n<p>Undervoltage <\/p>\n<\/td>\n<td>\n<p>This warning occurs before an A.410 alarm <br \/>(Undervoltage) occurs. If the warning is ignored and operation is continued, an alarm may occur.<\/p>\n<\/td>\n<td>\n<p>YES <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.97A <\/p>\n<\/td>\n<td>\n<p>Command warning 7 (layer exception)<\/p>\n<\/td>\n<td>\n<p>An instruction that cannot be executed is specified in the current layer.<\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.97b <\/p>\n<\/td>\n<td>\n<p>Out-of-data range data clamp element<\/p>\n<\/td>\n<td>\n<p>Fixed by setting the minimum value and maximum value outside the range of the command data.<\/p>\n<\/td>\n<td>\n<p>automatic reset*<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.9A0<\/p>\n<\/td>\n<td>\n<p>Overtravel<\/p>\n<\/td>\n<td>\n<p>Overtravel was detected while the servo was ON.<\/p>\n<\/td>\n<td>\n<p>YES<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> NOTE:1. A warning code is not output unless you set Pn001 to n.1 \u25af\u25af\u25af (Output both alarm codes and warning codes). \t 2.Use Pn008 = n.\u25afX \u25af\u25af (Warning Detection Selection) to control warning detection.         <\/p>\n<p> However, the following warnings are not affected by the setting of Pn008 = n.\u25afX \u25af\u25af and other parameter  settings are required in addition to Pn008 = n.\u25afX \u25af\u25af. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Warning<\/p>\n<\/td>\n<td>\n<p>Parameters That Must Be Set to Select Warning Detection<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.911 <\/p>\n<\/td>\n<td>\n<p>Pn310 = n.\u25af\u25af\u25afX (Vibration Detection Selection) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.923 <\/p>\n<\/td>\n<td>\n<p>\uff0d <br \/>(Not affected by the setting of Pn008 = n.\u25afX \u25af\u25af.) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.930<\/p>\n<\/td>\n<td>\n<p>Pn008 = n. \tX (Low Battery Voltage Alarm\/Warning Selection)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.942 <\/p>\n<\/td>\n<td>\n<p>Pn423=n.\u25af\u25afX\u25af (Speed Ripple Compensation Information Disagreement Warning Detection Selection) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>A.94A <br \/>A.960 A.97A <br \/>A.97b<\/p>\n<\/td>\n<td>\n<p>\uff5e\uff5e<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Pn800=n.\u25af\u25afX\u25af (Warning Check Mask) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.971 <\/p>\n<\/td>\n<td>\n<p>Pn008 = n.\u25af\u25afX\u25af (Function Selection for Undervoltage) <\/p>\n<p>(Not affected by the setting of Pn008 = n. X .)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.9A0 <\/p>\n<\/td>\n<td>\n<p>Pn00D = n.X\u25af\u25af\u25af (Overtravel Warning Detection Selection) (Not affected by the setting of Pn008 = n.\u25afX \u25af\u25af.) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.9b0<\/p>\n<\/td>\n<td>\n<p>Pn00F = n. X (Preventative Maintenance Warning Selection)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>9.3.2 Troubleshooting Warnings <br \/>The causes of and corrections for the warnings are given in the following table. <\/p>\n<p>Contact your Fatek representative if you cannot solve a problem with the correction given in the table. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Warning <br \/>Number: <br \/>Warning Name<\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.900\uff1a <br \/>Position <br \/>Deviation Overflow <\/p>\n<\/td>\n<td>\n<p>The Servomotor <br \/>U, V, and W wiring is not correct. <\/p>\n<\/td>\n<td>\n<p>Check the wiring of the <br \/>Servomotor\u2019s Main Circuit Cables.<\/p>\n<\/td>\n<td>\n<p>Make sure that there are no faulty connections in the <br \/>wiring for the Servomotor and encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A servo driver <br \/>gain is too low. <\/p>\n<\/td>\n<td>\n<p>Check the servo driver <br \/>gains.<\/p>\n<\/td>\n<td>\n<p>Increase the servo gain, e.g., by using autotuning without a host reference. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The acceleration of the position reference is too high. <\/p>\n<\/td>\n<td>\n<p>Reduce the reference acceleration and try operating the servo driver.<\/p>\n<\/td>\n<td>\n<p>Reduce the &quot;position command&quot; acceleration. Or, select the &quot;Position Command&quot; filter to smooth the &quot;Position Command&quot; acceleration. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The excessive position <br \/>deviation alarm level (Pn520) is too low for the operating <br \/>conditions. <\/p>\n<\/td>\n<td>\n<p>Check excessive <br \/>position deviation <br \/>alarm level (Pn520) to see if it is set to an <br \/>appropriate value.<\/p>\n<\/td>\n<td>\n<p>Optimize the settings of Pn520 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn the power supply to the servo driver OFF and ON again. If the alarm still occurs, the servo driver <br \/>may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.901\uff1a <br \/>Position <br \/>Deviation <br \/>Overflow Alarm at <br \/>Servo ON <\/p>\n<\/td>\n<td>\n<p>The position deviation when the servo was turned ON <br \/>exceeded the percentage set with the following formula: (Pn526 \u00d7 Pn528\/ 100) <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Optimize the setting of Pn528 (Position Deviation Overflow Warning Level at Servo ON). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.910\uff1a <br \/>Overload <br \/>(warning <br \/>before an A.710 or <br \/>A.720 alarm <br \/>occurs <\/p>\n<\/td>\n<td>\n<p>The wiring is not correct or there is a faulty connection in the motor or encoder wiring.<\/p>\n<\/td>\n<td>\n<p>Check the wiring. <\/p>\n<\/td>\n<td>\n<p>Make sure that the Servomotor and encoder are correctly <br \/>wired.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Operation was performed that exceeded the overload <br \/>protection characteristics <\/p>\n<\/td>\n<td>\n<p>Check the motor overload <br \/>characteristics and Run command.<\/p>\n<\/td>\n<td>\n<p>Reconsider the load and operating conditions. Or, increase the motor capacity. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An excessive load was applied during operation because the Servomotor was not driven because of mechanical <br \/>problems.<\/p>\n<\/td>\n<td>\n<p>Check the operation reference and motor speed. <\/p>\n<\/td>\n<td>\n<p>Remove the mechanical <br \/>problem. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The overload warning level (Pn52B) is not suitable. <\/p>\n<\/td>\n<td>\n<p>Check that the <br \/>overload <br \/>warning level (Pn52B) is <br \/>suitable.<\/p>\n<\/td>\n<td>\n<p>Set a suitable overload <br \/>warning level (Pn52B). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.911\uff1a <br \/>Vibration <\/p>\n<\/td>\n<td>\n<p>Abnormal vibration was detected during motor operation. <\/p>\n<\/td>\n<td>\n<p>Check for abnormal motor noise, and <br \/>check the speed and torque waveforms <br \/>during operation.<\/p>\n<\/td>\n<td>\n<p>Reduce the motor speed. Or, reduce the servo gain with custom tuning. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn103 (Moment of Inertia Ratio) is greater than the <br \/>actual moment of inertia or was greatly changed.<\/p>\n<\/td>\n<td>\n<p>Check the moment of inertia ratio or mass ratio. <\/p>\n<\/td>\n<td>\n<p>Set Pn103 (Moment of Inertia Ratio) to an appropriate <br \/>value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The vibration detection level (Pn312 or Pn384) is not <br \/>suitable. <\/p>\n<\/td>\n<td>\n<p>Check that the <br \/>vibration <br \/>detection level (Pn312 or Pn384) is suitable.<\/p>\n<\/td>\n<td>\n<p>Set a suitable vibration detection level (Pn312 or Pn384). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.920\uff1a <br \/>Regenerative <br \/>Overload <br \/>(warning before<\/p>\n<\/td>\n<td>\n<p>The power supply voltage <br \/>exceeded the specified range. <\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Set the power supply voltage within the specified <br \/>range. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>an A.320 alarm occurs) <\/p>\n<\/td>\n<td>\n<p>There is insufficient external regenerative resistance, <br \/>regenerative <br \/>resistor capacity, or <br \/>servo driver <br \/>capacity, or there <br \/>has been a continuous <br \/>regeneration <br \/>state.<\/p>\n<\/td>\n<td>\n<p>Check the operating conditions. <\/p>\n<\/td>\n<td>\n<p>Change the regenerative <br \/>resistance value, regenerative resistance capacity <br \/>. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There was a continuous regeneration <br \/>state because <br \/>a negative load <br \/>was continuously <br \/>applied.<\/p>\n<\/td>\n<td>\n<p>Check the load <br \/>applied <br \/>to the Servomotor during operation. <\/p>\n<\/td>\n<td>\n<p>Reconsider the system <br \/>including the servo, <br \/>machine, and operating <br \/>conditions. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.921\uff1a <br \/>Dynamic Brake Overload <br \/>(warning <br \/>before an A.731 alarm occurs) <\/p>\n<\/td>\n<td>\n<p>The Servomotor was rotated by an external force. <\/p>\n<\/td>\n<td>\n<p>Check the operation status. <\/p>\n<\/td>\n<td>\n<p>Implement measures to <br \/>ensure that the motor will <br \/>not be rotated by an external force.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>When the Servomotor was <br \/>stopped with the <br \/>dynamic brake, <br \/>the rotational or <br \/>linear kinetic <br \/>energy exceeded <br \/>the capacity of the <br \/>dynamic brake <br \/>resistor.<\/p>\n<\/td>\n<td>\n<p>Check the power <br \/>consumed <br \/>by the DB resistor to see how <br \/>frequently the DB is being used. <\/p>\n<\/td>\n<td>\n<p>Reconsider the following: \u2022 Reduce the Servomotor command speed. <\/p>\n<p>\u2022 Decrease the moment of inertia or mass. <\/p>\n<p>\u2022 Reduce the frequency of stopping with the dynamic brake. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>A.930\uff1a <br \/>Absolute <br \/>Encoder <br \/>Battery Error <br \/>(The <br \/>absolute <br \/>encoder <br \/>battery voltage was <br \/>lower than the specified <br \/>level.) (Detected only when an <br \/>absolute <br \/>encoder is <br \/>connected.)<\/p>\n<\/td>\n<td>\n<p>The battery connection is faulty or <br \/>a battery is not <br \/>connected.<\/p>\n<\/td>\n<td>\n<p>Check the battery connection. <\/p>\n<\/td>\n<td>\n<p>Correct the battery connection. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The battery voltage is lower than <br \/>the specified value (2.7 V).<\/p>\n<\/td>\n<td>\n<p>Measure the battery voltage. <\/p>\n<\/td>\n<td>\n<p>Replace the battery. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>A.971\uff1a <br \/>Undervoltage <\/p>\n<\/td>\n<td>\n<p>Servo drive AC power supply voltage is too low.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage.<\/p>\n<\/td>\n<td>\n<p>Adjust the power supply voltage to the normal range.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The power supply voltage dropped <br \/>during operation.<\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>Increase the power supply capacity. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A momentary <br \/>power interruption occurred. <\/p>\n<\/td>\n<td>\n<p>Measure the power supply voltage. <\/p>\n<\/td>\n<td>\n<p>If you have changed the <br \/>setting of Pn509 (Momentary Power Interruption Hold <br \/>Time), decrease the setting.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The servo driver fuse is blown out.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Replace the servo driver <br \/>and connect a reactor<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.97A\uff1a <br \/>Instruction Warning 7<\/p>\n<\/td>\n<td>\n<p>An unexecutable instruction was received in the current layer<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Send the command after the sending conditions are met. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.97b\uff1a <br \/>Out of data range.<\/p>\n<\/td>\n<td>\n<p>A value outside the range is set in the command data. <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Set a value within the setting range in the command data. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.9A0\uff1a <br \/>Overtravel (Overtravel status was detected.) <\/p>\n<\/td>\n<td>\n<p>Overtravel was <br \/>detected while the servo was ON. <\/p>\n<\/td>\n<td>\n<p>Check the status of the <br \/>overtravel signals on the input signal <br \/>monitor. <\/p>\n<\/td>\n<td>\n<p>Even if an overtravel signal is not shown by the input signal monitor, momentary overtravel may have been detected. Take the following precautions. <\/p>\n<p>\u2022 Do not specify movements that would cause <br \/>overtravel from the host<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p>controller. <\/p>\n<p>\u2022 Check the wiring of the <br \/>overtravel signals. <\/p>\n<p>\u2022 Implement countermeasures against noise.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.4 Monitoring of communication data when error alarms and warnings <\/h3>\n<p>The command data when an error alarm or warning (for example: data setting warning (A.94\u25af), command warning (A.95\u25af)) occurs can be monitored through the following parameters. The following is the data when an error alarm or warning occurs under normal conditions. <\/p>\n<p>CMD data when error alarm or warning occurs: Pn890\uff5ePn8A6 <br \/>RSP data when error alarm or warning occurs: Pn8A8\uff5ePn8BE <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Command byte order<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>The location where the command data is saved when an error alarm or warning occurs<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CMD<\/p>\n<\/td>\n<td>\n<p>RSP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Pn890 = n.\u25af\u25af\u25af\u25af\u25af\u25afXX<\/p>\n<\/td>\n<td>\n<p>Pn8A8 = n.\u25af\u25af\u25af\u25af\u25af\u25afXX<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Pn890 = n.\u25af\u25af\u25af\u25afXX\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Pn8A8 = n.\u25af\u25af\u25af\u25afXX\u25af\u25af<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Pn890 = n.\u25af\u25afXX\u25af\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Pn8A8 = n.\u25af\u25afXX\u25af\u25af\u25af\u25af<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>Pn890 = n.XX\u25af\u25af\u25af\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Pn8A8 = n.XX\u25af\u25af\u25af\u25af\u25af\u25af<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4\uff5e7<\/p>\n<\/td>\n<td>\n<p>Pn892<\/p>\n<\/td>\n<td>\n<p>Pn8AA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8\uff5e11 <\/p>\n<\/td>\n<td>\n<p>Pn894 <\/p>\n<\/td>\n<td>\n<p>Pn8AC <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>12\uff5e15<\/p>\n<\/td>\n<td>\n<p>Pn896<\/p>\n<\/td>\n<td>\n<p>Pn8AE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>16\uff5e19<\/p>\n<\/td>\n<td>\n<p>Pn898<\/p>\n<\/td>\n<td>\n<p>Pn8B0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>20\uff5e23<\/p>\n<\/td>\n<td>\n<p>Pn89A<\/p>\n<\/td>\n<td>\n<p>Pn8B2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>24\uff5e27<\/p>\n<\/td>\n<td>\n<p>Pn89C<\/p>\n<\/td>\n<td>\n<p>Pn8B4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>28\uff5e31 <\/p>\n<\/td>\n<td>\n<p>Pn89E <\/p>\n<\/td>\n<td>\n<p>Pn8B6 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>32\uff5e35<\/p>\n<\/td>\n<td>\n<p>Pn8A0<\/p>\n<\/td>\n<td>\n<p>Pn8B8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>36\uff5e39<\/p>\n<\/td>\n<td>\n<p>Pn8A2<\/p>\n<\/td>\n<td>\n<p>Pn8BA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>40\uff5e43 <\/p>\n<\/td>\n<td>\n<p>Pn8A4 <\/p>\n<\/td>\n<td>\n<p>Pn8BC <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>44\uff5e47<\/p>\n<\/td>\n<td>\n<p>Pn8A6<\/p>\n<\/td>\n<td>\n<p>Pn8BE<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: The data is arranged in little endian storage order and expressed in hexadecimal. <\/p>\n<p>9.5 Troubleshooting Based on the Operation and Conditions of the Servomotor This section provides troubleshooting based on the operation and conditions of the Servomotor, including causes and corrections. When checking and handling the items in the thick line box in the table below, be sure to cut off the power supply of the servo system. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Problem <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"6\"><\/td>\n<td colspan=\"2\" rowspan=\"3\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>The control power supply is not turned ON. <\/p>\n<\/td>\n<td>\n<p>Measure the voltage <br \/>between control power supply terminals. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>system. Correct the wiring so that the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>control power supply is turned ON. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>The main circuit power supply is not turned ON. <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Measure the voltage between the main circuit power input terminals.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>system. Correct the wiring so that the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>main circuit power supply is turned ON.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\"><\/td>\n<td colspan=\"2\" rowspan=\"9\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>The I\/O signal connector (CN1) pins are not wired correctly <br \/>or are disconnected. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the wiring condition of the I\/O signal connector (CN1) pins.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The wiring for the <br \/>Servomotor Main Circuit Cables or Encoder Cable is disconnected. <\/p>\n<\/td>\n<td>\n<p>Check the wiring conditions. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Correct the wiring of <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>the I\/O signal connector <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>(CN1) pins. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td rowspan=\"2\">\n<p>Turn OFF the power <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Does Not <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>supply to the servo <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Start <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Wire the cable correctly. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>There is an overload on the Servomotor. <\/p>\n<\/td>\n<td>\n<p>Operate the Servomotor with no load and check the load status. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Reduce the load or replace the Servo Motor with a Servo Motor with a larger capacity. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The type of encoder that is being used does not agree with the setting of Pn002 = n.\u25afX \u25af\u25af (Encoder Usage).<\/p>\n<\/td>\n<td>\n<p>Check the type of the encoder that is being used and the setting of Pn002 = n.\u25afX \u25af\u25af. <\/p>\n<\/td>\n<td>\n<p>Set Pn002 = n.\u25afX \u25af\u25af according to the type of the encoder that is <br \/>being used. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"5\"><\/td>\n<td>\n<p>There is a mistake in the input signal allocations (Pn50A, Pn50B, Pn511, Pn516).<\/p>\n<\/td>\n<td>\n<p>Confirm the setting values of input signals (Pn50A, Pn50B, Pn511, <br \/>Pn516). <\/p>\n<\/td>\n<td>\n<p>Correctly allocate input signals (Pn50A, Pn50B, Pn511, Pn516). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>No servo ON(SV-ON) command <\/p>\n<\/td>\n<td>\n<p>Confirm the instructions from the host device. <\/p>\n<\/td>\n<td>\n<p>Input the servo ON (SV_ON) command from the host device. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is no sensor ON (SENS_ON) command <\/p>\n<\/td>\n<td>\n<p>Confirm the instructions from the host device. <\/p>\n<\/td>\n<td>\n<p>Send instructions to the servo drive in the correct sequence. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Prohibit) signal is still OFF.<\/p>\n<\/td>\n<td>\n<p>Check the P-OT and NOT signals. <\/p>\n<\/td>\n<td>\n<p>Turn ON the P-OT and N-OT signals. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The FSTP (Forced Stop Input) signal is still OFF. <\/p>\n<\/td>\n<td>\n<p>Check the FSTP signal. <\/p>\n<\/td>\n<td>\n<p>\u2022 Turn ON the FSTP signal. <\/p>\n<p>\u2022 If you will not use the function to <br \/>force the motor to stop, set Pn516 = n.\u25af\u25af\u25afX (FSTP (Forced Stop Input) Signal Allocation) to disable the signal.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>The servo motor <\/p>\n<p>Servo motor wiring error <\/p>\n<p>runs <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>momentarily <br \/>and then stops.<\/p>\n<\/td>\n<td>\n<p>Wiring error of encoder or serial conversion unit <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Confirm the wiring. <\/p>\n<\/td>\n<td>\n<p>Correct wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Confirm the wiring. <\/p>\n<\/td>\n<td>\n<p>Correct wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">\n<p>Servo motor operation is unstable <\/p>\n<\/td>\n<td rowspan=\"8\">\n<p>There is a faulty connection in the Servomotor wiring. <\/p>\n<\/td>\n<td>\n<p>The connector connections for the <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Tighten any loose terminals or <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>power line (U, V, and W phases) and <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>the encoder or Serial Converter Unit <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>connectors <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>may be unstable. Turn OFF the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>and correct the wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>power supply to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the wiring.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Problem <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Servomotor <br \/>Moves without a Reference Input<\/p>\n<\/td>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>Check that the directions match. <\/p>\n<\/td>\n<td>\n<p>Replace servo drive. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Dynamic <br \/>Brake Does <br \/>Not Operate <\/p>\n<\/td>\n<td>\n<p>The setting of Pn001 = n.\u25af\u25af\u25afX (Motor Stopping <br \/>Method for Servo OFF and Group 1 Alarms) is not <br \/>suitable.<\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn001 = n.\u25af\u25af\u25afX. <\/p>\n<\/td>\n<td>\n<p>Set Pn001 = n.\u25af\u25af\u25afX correctly. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The dynamic brake resistor is disconnected. <\/p>\n<\/td>\n<td>\n<p>Check the moment of inertia, motor speed, and dynamic brake <br \/>frequency of use. If the moment of inertia, motor speed, or dynamic brake frequency of use is excessive, the dynamic brake resistance may be disconnected.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Replace the servo driver. To <br \/>prevent disconnection, reduce the load.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There was a failure in the dynamic brake drive circuit.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>There is a defective component in the dynamic brake circuit. <\/p>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Abnormal Noise from <br \/>Servomotor <\/p>\n<\/td>\n<td>\n<p>The Servomotor vibrated considerably while <br \/>performing the tuning -less function with the default <br \/>settings.<\/p>\n<\/td>\n<td>\n<p>Check the waveform of the motor speed. <\/p>\n<\/td>\n<td>\n<p>Reduce the load so that the moment of inertia ratio or mass ratio is within the allowable value, or increase the load level or reduce the rigidity level in the tuning-less level settings.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The machine mounting is not secure. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check to see if there are any loose mounting screws. <\/p>\n<\/td>\n<td>\n<p>Tighten the mounting screws. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The machine mounting is not secure. <\/p>\n<\/td>\n<td>\n<p>Check whether the coupling is eccentric. <\/p>\n<\/td>\n<td>\n<p>Align the core of the coupling. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The bearings are defective.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check for noise and <br \/>vibration around the bearings. <\/p>\n<\/td>\n<td>\n<p>Replace the Servomotor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a vibration source at the driven machine. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check for any foreign matter, damage, or deformation in the machine\u2019s moving parts.<\/p>\n<\/td>\n<td>\n<p>Consult with the machine manufacturer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because of incorrect I\/O <br \/>signal cable specifications.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check the I\/O signal cables to see if they satisfy <\/p>\n<\/td>\n<td>\n<p>Use cables that satisfy the specifications.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"11\"><\/td>\n<td><\/td>\n<td>\n<p>specifications. Use shielded twisted-pair cables or screened twisted-pair cables with conductors of at least 0.12 mm2 (stranded wire).<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because an I\/O signal cable is too long. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check the lengths of the I\/O signal cables. <\/p>\n<\/td>\n<td>\n<p>The I\/O signal cables <br \/>must be no longer than 3 m. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because of incorrect <br \/>Encoder Cable <br \/>specifications. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check the Encoder Cable to see if it satisfies <br \/>specifications. Use shielded twisted-pair cables or screened twisted-pair cables with conductors of at least 0.12 mm2 (stranded wire).<\/p>\n<\/td>\n<td>\n<p>Use cables that satisfy the specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because the Encoder Cable is too long. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the length of the Encoder Cable.<\/p>\n<\/td>\n<td>\n<p>Rotary Servomotors: The Encoder Cable length must be 50 m max. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because the Encoder Cable is damaged. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the Encoder Cable to see if it is pinched or the sheath is damaged.<\/p>\n<\/td>\n<td>\n<p>Replace the Encoder <br \/>Cable and correct the <br \/>cable installation environment. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Encoder Cable was <br \/>subjected to excessive noise interference. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check to see if the <br \/>Encoder Cable is bundled with a high-current line or installed near a high-current line.<\/p>\n<\/td>\n<td>\n<p>Correct the cable layout so that no surge is <br \/>applied by high-current lines. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is variation in the FG potential because of the influence of machines on the <br \/>Servomotor side, such as a welder.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check to see if the <br \/>machines are correctly grounded. <\/p>\n<\/td>\n<td>\n<p>Properly ground the machines to separate them from the FG of the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a servo driver pulse counting error due to noise.<\/p>\n<\/td>\n<td>\n<p>Check to see if there is noise interference on the signal line from the <br \/>encoder. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Implement countermeasures against noise <br \/>for the encoder wiring.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The encoder was subjected to excessive vibration or shock. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check to see if vibration <br \/>from the machine <br \/>occurred. Check the Servomotor installation <br \/>(mounting surface precision, <br \/>securing state, and <br \/>alignment). <\/p>\n<p>Check the linear encoder <br \/>installation (mounting surface precision and securing <br \/>method).<\/p>\n<\/td>\n<td>\n<p>Reduce machine vibration. <\/p>\n<p>Improve the <br \/>mounting state of the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Replace the Servomotor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the Serial Converter Unit. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Replace the Serial Converter Unit. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Servomotor <br \/>Vibrates at <br \/>Frequency of <br \/>Approx. 200 to 400 Hz. <\/p>\n<\/td>\n<td>\n<p>The servo gains are not balanced. <\/p>\n<\/td>\n<td>\n<p>Check to see if the servo gains have been correctly tuned. <\/p>\n<\/td>\n<td>\n<p>Perform autotuning without a host reference. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn100 (Speed Loop Gain) is too high. <\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn100. <\/p>\n<p>The default setting is Kv = 40.0 Hz.<\/p>\n<\/td>\n<td>\n<p>Set Pn100 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\"><\/td>\n<td>\n<p>The setting of Pn102 <br \/>(Position Loop Gain) is too high. <\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn102. <\/p>\n<p>The default setting is Kp = 40.0\/s.<\/p>\n<\/td>\n<td>\n<p>Set Pn102 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn101 (Speed Loop Integral Time <br \/>Constant) <br \/>is not appropriate.<\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn101. <\/p>\n<p>The default setting is Ti = 20.0 ms.<\/p>\n<\/td>\n<td>\n<p>Set Pn101 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn103 <br \/>(Moment of Inertia Ratio or Mass Ratio) is not <br \/>appropriate.<\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn103. <\/p>\n<\/td>\n<td>\n<p>Set Pn103 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p>Large Motor Speed <br \/>Overshoot on Starting and <br \/>Stopping <\/p>\n<\/td>\n<td>\n<p>The servo gains are not balanced. <\/p>\n<\/td>\n<td>\n<p>Check to see if the servo gains have been correctly tuned. <\/p>\n<\/td>\n<td>\n<p>Perform autotuning without a host reference. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn100 (Speed Loop Gain) is too high. <\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn100. <\/p>\n<p>The default setting is Kv = 40.0 Hz.<\/p>\n<\/td>\n<td>\n<p>Set Pn100 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn102 <br \/>(Position <br \/>Loop Gain) is too high. <\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn102. <\/p>\n<p>The default setting is Kp = 40.0\/s.<\/p>\n<\/td>\n<td>\n<p>Set Pn102 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn101 (Speed Loop Integral Time <br \/>Constant) <br \/>is not appropriate.<\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn101. <\/p>\n<p>The default setting is Ti = 20.0 ms.<\/p>\n<\/td>\n<td>\n<p>Set Pn101 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of Pn103 <br \/>(Moment of Inertia Ratio or Mass Ratio) is not <br \/>appropriate.<\/p>\n<\/td>\n<td>\n<p>Check the setting of Pn103. <\/p>\n<\/td>\n<td>\n<p>Set Pn103 to an appropriate value. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The torque reference is saturated. <\/p>\n<\/td>\n<td>\n<p>Check the waveform of the torque reference. <\/p>\n<\/td>\n<td>\n<p>Use the mode switch. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The force limits (Pn483 and Pn484) are set to the default values.<\/p>\n<\/td>\n<td>\n<p>The default values of the force limits are Pn483 = 30% and Pn484 = 30%.<\/p>\n<\/td>\n<td>\n<p>Set Pn483 and Pn484 to appropriate values. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Problem <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Absolute <br \/>Encoder Position Deviation Error <br \/>(The position <br \/>that was saved <br \/>in the host <br \/>controller when the power was <br \/>turned OFF is <br \/>different from <br \/>the position <br \/>when the power was next turned ON.) <\/p>\n<\/td>\n<td>\n<p>Noise interference occurred because of incorrect <br \/>Encoder Cable <br \/>specifications. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the Encoder Cable <br \/>to see if it satisfies specifications. <\/p>\n<p>Use shielded <br \/>twisted-pair cables or <br \/>screened twisted-pair <br \/>cables with conductors of at least 0.12 mm2 <br \/>(stranded wire).<\/p>\n<\/td>\n<td>\n<p>Use cables that satisfy the specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because the Encoder Cable is too long. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the length of the Encoder Cable. <\/p>\n<\/td>\n<td>\n<p>Rotary Servomotors: The Encoder Cable length must be 50 m max. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Noise interference occurred because the Encoder Cable is damaged. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the Encoder Cable to see if it is pinched or the sheath is damaged.<\/p>\n<\/td>\n<td>\n<p>Replace the Encoder <br \/>Cable and correct the <br \/>cable installation environment. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The Encoder Cable was subject to excessive noise interference. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check to see if the Encoder Cable is bundled with a high-current line or installed near a high-current line.<\/p>\n<\/td>\n<td>\n<p>Correct the cable layout so that no surge is <br \/>applied by high-current lines. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is variation in the FG potential because of the influence of machines on the Servomotor side, such as a welder.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check to see if the <br \/>machines are correctly grounded.<\/p>\n<\/td>\n<td>\n<p>Properly ground the machines to separate them from the FG of the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is a servo driver pulse counting error due to noise.<\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check to see if there is noise interference on the I\/O <br \/>signal line from the encoder or <br \/>Serial Converter Unit.<\/p>\n<\/td>\n<td>\n<p>Implement countermeasures against noise for the encoder or Serial <br \/>Converter Unit wiring. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"6\"><\/td>\n<td>\n<p>The encoder was subjected to excessive vibration or <br \/>shock. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. Check to see if <br \/>vibration from the machine <br \/>occurred. Check the Servomotor installation (mounting surface <br \/>precision, securing state, and <br \/>alignment). Check the linear <br \/>encoder installation (mounting surface precision and securing method).<\/p>\n<\/td>\n<td>\n<p>Reduce machine vibration. Improve the mounting state of the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the encoder. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Replace the Servomotor or linear encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A failure occurred in the servo driver. <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Host Controller Multiturn Data or Absolute Encoder Position Data Reading Error<\/p>\n<\/td>\n<td>\n<p>Check the error detection section of the host <br \/>controller. <\/p>\n<\/td>\n<td>\n<p>Correct the error detection section of the host <br \/>controller. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check to see if the host controller is executing data parity checks. <\/p>\n<\/td>\n<td>\n<p>Perform parity checks <br \/>for the multiturn data or absolute encoder position data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check for noise interference in the cable <br \/>between the servo driver <br \/>and the host controller. <\/p>\n<\/td>\n<td>\n<p>Implement countermeasures against noise <br \/>and then perform parity <br \/>checks again for the <br \/>multiturn data or absolute encoder position <br \/>data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\">\n<p>Overtravel <br \/>Occurred (OT) <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>The P-OT\/N-OT (Forward Drive Prohibit or Reverse Drive Prohibit) signal was input. <\/p>\n<\/td>\n<td>\n<p>Check the external power supply (+24 V) voltage for the input signals. <\/p>\n<\/td>\n<td>\n<p>Correct the external power supply (+24 V) voltage for the input signals.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the operating condition of the overtravel limit switches. <\/p>\n<\/td>\n<td>\n<p>Make sure that the <br \/>overtravel limit switches operate correctly. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the wiring of the overtravel limit switches. <\/p>\n<\/td>\n<td>\n<p>Correct the wiring of the overtravel limit switches. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the settings of the overtravel input signal allocations <br \/>(Pn50A\/Pn50B).<\/p>\n<\/td>\n<td>\n<p>Set the parameters to correct values. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>The P-OT\/N-OT (Forward Drive Prohibit or Reverse Drive Prohibit) signal <br \/>malfunctioned. <\/p>\n<\/td>\n<td>\n<p>Check for fluctuation in <br \/>the external power supply (+24 V) voltage for the <br \/>input signals.<\/p>\n<\/td>\n<td>\n<p>Eliminate fluctuation <br \/>from the external power supply (+24 V) voltage for the input signals.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check to see if the operation of the overtravel limit <br \/>switches is unstable. <\/p>\n<\/td>\n<td>\n<p>Stabilize the operating <br \/>condition of the overtravel limit switches. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the wiring of the overtravel limit switches (e.g., check for cable <br \/>damage and loose <br \/>screws).<\/p>\n<\/td>\n<td>\n<p>Correct the wiring of the overtravel limit switches. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>There is a mistake in the <br \/>allocation of the P-OT or N-OT (Forward Drive Prohibit or Reverse Drive Prohibit) signal in Pn50A = n.X \u25af\u25af\u25af or Pn50B = n.\u25af\u25af\u25afX. <\/p>\n<\/td>\n<td>\n<p>Check to see if the P-OT signal is allocated in <br \/>Pn50A = n.X\u25af\u25af\u25af. <\/p>\n<\/td>\n<td>\n<p>If another signal is allocated in Pn50A <br \/>=n.X \u25af\u25af\u25af, allocate the <br \/>P-OT signal instead.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check to see if the N-OT signal is allocated in <br \/>Pn50B = n.\u25af\u25af\u25afX. <\/p>\n<\/td>\n<td>\n<p>If another signal is allocated in Pn50B <br \/>=n.\u25af\u25af\u25afX, allocate the <br \/>N-OT signal instead.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>The selection of the Servomotor <br \/>stopping method is not correct. <\/p>\n<\/td>\n<td>\n<p>Check the servo OFF <br \/>stopping method set in Pn001 = n.\u25af\u25af\u25afX or <br \/>Pn001 = n. X .<\/p>\n<\/td>\n<td>\n<p>Select a Servomotor <br \/>stopping method other than coasting to a stop. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the torque control <\/p>\n<p>stopping method set in Pn001 = <\/p>\n<p>n. \tX orPn001 = n. \tX.<\/p>\n<\/td>\n<td>\n<p>Select a Servomotor <br \/>stopping method other than coasting to a stop.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Improper Stop Position for <br \/>Overtravel (OT) Signal <\/p>\n<\/td>\n<td>\n<p>The limit switch position and dog length are not <br \/>appropriate.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Install the limit switch at the appropriate position. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The overtravel limit switch position is too close for the coasting distance.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>Install the overtravel limit switch at the <br \/>appropriate position.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Problem <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Confirmation <\/p>\n<\/td>\n<td>\n<p>Correction <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"8\"><\/td>\n<td rowspan=\"8\">\n<p>Noise interference occurred because of incorrect <br \/>Encoder <br \/>Cable specifications. <\/p>\n<\/td>\n<td>\n<p>Check the Encoder Cable <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Use cables that satisfy <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to see if it satisfies specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Use shielded <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>twisted-pair cables or <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>screened twisted-pair <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>the specifications. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>cables with conductors of <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>at least 0.12 mm2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>(stranded wire).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><\/td>\n<td rowspan=\"4\">\n<p>Noise interference occurred because the Encoder Cable is too long. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td>\n<p>Rotary Servomotors: <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<td>\n<p>The Encoder Cable <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the length of the <\/p>\n<\/td>\n<td>\n<p>length must be 50 m <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Encoder Cable. <\/p>\n<\/td>\n<td>\n<p>max. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\"><\/td>\n<td rowspan=\"6\">\n<p>Noise interference occurred because the Encoder Cable is damaged. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Replace the Encoder Cable and correct <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Check the Encoder Cable <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>the cable installation environment. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to see if it is pinched or <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>the sheath is damaged.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"10\"><\/td>\n<td rowspan=\"10\">\n<p>The Encoder Cable was subjected <br \/>to excessive noise <br \/>interference. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Correct the cable layout <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Check to see if the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>so that no surge is <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Encoder Cable is bundled <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>applied by high-current <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>with a high-current line or <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>lines. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>installed near a high-current <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>line.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\"><\/td>\n<td rowspan=\"8\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>There is variation in the FG potential because of the influence of machines on the <br \/>Servomotor side, such as a welder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Properly ground the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>machines to separate <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Check to see if the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>them from the FG of <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>machines are correctly <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>the encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>grounded. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Position <\/p>\n<\/td>\n<td rowspan=\"7\">\n<p>There is a servo driver <br \/>pulse counting error due to noise. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Implement countermeasures <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Deviation <\/p>\n<\/td>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>(without Alarm)<\/p>\n<\/td>\n<td>\n<p>Check to see if there is <\/p>\n<\/td>\n<td>\n<p>against noise <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>noise interference on the <\/p>\n<\/td>\n<td>\n<p>for the encoder wiring <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>I\/O signal line from the <\/p>\n<\/td>\n<td>\n<p>or Serial Converter Unit <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>encoder or Serial Converter <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>wiring. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Unit.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"13\"><\/td>\n<td rowspan=\"13\">\n<p>The encoder was subjected to excessive vibration or <br \/>shock. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Reduce machine vibration. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check to see if vibration <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>from the machine <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>occurred. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the Servomotor <\/p>\n<\/td>\n<td>\n<p>Improve the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>installation (mounting surface <\/p>\n<\/td>\n<td>\n<p>mounting state of the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>precision, securing <\/p>\n<\/td>\n<td>\n<p>Servomotor or linear <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>state, and alignment). <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>encoder. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Check the linear encoder <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>installation (mounting surface <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>precision and securing <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>method).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\"><\/td>\n<td rowspan=\"8\">\n<p>The coupling between the machine and Servomotor is not suitable. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Correctly secure the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>to the servo system. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Check to see if position <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>coupling between the <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>offset occurs at the coupling <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>machine and Servomotor. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>between machine <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>and Servomotor. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>Noise interference occurred because of incorrect I\/O <br \/>signal cable specifications. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the I\/O signal <br \/>cables to see if they satisfy specifications. Use <br \/>shielded twisted-pair <br \/>cables or screened<\/p>\n<\/td>\n<td>\n<p>Use cables that satisfy the specifications. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>twisted-pair cables with conductors of at least <br \/>0.12 mm2 (stranded wire).<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Noise interference occurred because an I\/O signal cable is too long. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Check the lengths of the I\/O signal cables.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An encoder fault occurred. (The pulse count does not change.) <\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>The I\/O signal cables <br \/>must be no longer than 3 m. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Replace the Servomotor or linear encoder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>A failure occurred in the servo driver.<\/p>\n<\/td>\n<td>\n<p>&#8211; <\/p>\n<\/td>\n<td>\n<p>The servo driver may be faulty. Replace the servo driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Servomotor Overheated <\/p>\n<\/td>\n<td>\n<p>The surrounding air <br \/>temperature is too high. <\/p>\n<\/td>\n<td>\n<p>Measure the surrounding air temperature around the <br \/>Servomotor.<\/p>\n<\/td>\n<td>\n<p>Reduce the surrounding air temperature to <br \/>40\u00b0C or less.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The surface of the Servomotor <br \/>is dirty. <\/p>\n<\/td>\n<td>\n<p>Turn OFF the power supply to the servo system. <\/p>\n<p>Visually check the surface for dirt.<\/p>\n<\/td>\n<td>\n<p>Clean dirt, dust, and oil from the surface. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>There is an overload on the Servomotor. <\/p>\n<\/td>\n<td>\n<p>Check the load status with a monitor. <\/p>\n<\/td>\n<td>\n<p>If the Servomotor is <br \/>overloaded, reduce the <br \/>load or replace the <br \/>Servo Drive with a <br \/>servo driver and Servomotor with larger <br \/>capacities.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>9.1 Inspections and Part Replacement This section descr [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3304","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3304"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3304\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}