{"id":3306,"date":"2026-11-17T18:41:17","date_gmt":"2026-11-17T10:41:17","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-11\/"},"modified":"2026-11-17T18:41:17","modified_gmt":"2026-11-17T10:41:17","slug":"sc3-sc3man-en-11","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-11\/","title":{"rendered":"Chapter 11 Tuning Software(ProTuner)"},"content":{"rendered":"<h2>Chapter11.Tuning Software\uff08ProTuner\uff09 <\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-001.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-002.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-003.png\" \/><\/p>\n<p>Using the host computer software (ProTuner), the following functions can be realized online: \u2022 Parameter management: parameter setting and adjustment <br \/>\u2022 Status monitoring: Monitor the working status and related data of the servo system <br \/>\u2022 Use tracking: Use tracking for servo power, instructions, output current and other related data \u2022 Auxiliary debugging: realize online auxiliary debugging of servo functions using the host computer <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>11.1  ProTuner Connect and login <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>1. Install the ProTuner debugging software on the PC <br \/>2. Connect the PC to the MiniUSB interface on the servo drive panel operator through a USB cable Connection, the communication interface is shown in the picture on the right. <\/p>\n<p>3. After the communication line is correctly connected, execute the ProTuner debugging software on the PC <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-004.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>(as shown in the picture). <\/p>\n<p>When the [User Login] window is displayed, click the [Search] button (Figure 1). <\/p>\n<p>4. After the [Connect] window is displayed, select the searched drive address 1 or address 2, and then click the [Connect] button (Figure 2). <\/p>\n<p>5. After the connection is successful, the [System Monitoring] shortcut window (Figure 3) and [ProTuner] debugging window (Figure 4) will be displayed.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-005.png\" \/><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-006.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-007.png\" \/><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-008.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-009.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Figure 3 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Figure 1<\/p>\n<\/td>\n<td>\n<p>Figure 2 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>At this time, the ProTuner debugging software is successfully connected. <\/p>\n<p>\u2022In the [ProTuner] debugging window, you can selectively monitor various statuses of the servo in each window. <\/p>\n<p>\u2022In the menu bar of the [ProTuner] debugging window, you can click the debugging shortcut button to enter the debugging interface.\u3002 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-010.png\" \/><\/p>\n<p>Figure 4 <\/p>\n<h3>11.2 Automatic Adjustment (No Upper-Level Commands) <\/h3>\n<p>Automatic Adjustment (No Upper-Level Commands) refers to the functionality where the servo unit operates autonomously (reciprocating motion in both forward and reverse) without receiving commands from upper-level devices, and adjusts itself during operation based on mechanical characteristics. <\/p>\n<p>The automatic adjustment items are as follows: <br \/>\u2022 Moment of inertia ratio <br \/>\u2022 Gain adjustment (speed loop gain, position loop gain) <br \/>\u2022 Filter adjustments (torque command filter, notch filter) <br \/>\u2022 Friction compensation <br \/>\u2022 Anti-resonance control <br \/>\u2022 Vibration suppression <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-011.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-012.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-013.png\" \/><\/p>\n<p>Automatic Adjustment (No Upper-Level Commands) adjustment is explained. <\/p>\n<p>\u2022 Automatic Adjustment (No Upper-Level Commands)Adjust based on the set speed loop gain (Pn100). If vibration occurs at the beginning of adjustment, correct adjustment will not be possible. Please reduce the speed loop gain (Pn100) until the vibration no longer occurs and then make adjustments. <\/p>\n<p>\u2022 Automatic Adjustment (No Upper-Level Commands) cannot be executed while the adjustment-free function is enabled (Pn170= \tn.\u25af\u25af\u25af1 [Default Setting]). Please disable the adjustment-free function (Pn170 = n.\u25af\u25af\u25af0) before making adjustments.\u3002 \u2022 After executing Automatic Adjustment (No Upper-Level Commands), change the load status or transmission mechanism of the \tmachine, and set the &quot;estimated moment of inertia&quot; again. When executing Automatic Adjustment (No Upper-Level Commands), \tplease refer to the following setting parameters. If automatic adjustment is performed in a state other than the following (without \tupper bit command), it may cause mechanical vibration and damage to the machine.\u3002 <\/p>\n<p> Pn140 = n.\u25af\u25af\u25af0 (Not using model tracking control) <br \/> Pn160 = n.\u25af\u25af\u25af0 (Not using anti-resonance control) <br \/> Pn408 = n.00\u25af0 (Not using friction compensation, first-stage and second-stage notch filters) <br \/>NOTE: When using a digital operator, if the above parameters are not displayed, please select the setting to display all \tparameters (Pn00B = n.\u25af\u25af\u25af1) and then power cycle the device. <\/p>\n<p>\u25a0Things to confirm before execution <br \/>Before executing Automatic Adjustment (No Upper-Level Commands), please ensure the following settings are confirmed: \u2022 Main Circuit Power supply must be ON\u3002 <\/p>\n<p>\u2022 There must be no over-travel. <\/p>\n<p>\u2022 The system must be in the servo OFF state. <\/p>\n<p>\u2022 Torque control must not be active. <\/p>\n<p>\u2022 The gain switch must be set to manual gain switching (Pn139 = n.\u25af\u25af\u25af0). <\/p>\n<p>\u2022 The first gain must be selected. <\/p>\n<p>\u2022 No error alarms or warnings should be present. <\/p>\n<p>\u2022 STO must be in the OFF state *1. <\/p>\n<p>\u2022 The write protection setting for parameters must not be set to &quot;Write Prohibited.&quot; <br \/>\u2022 The adjustment-free function must be disabled (Pn170 = n.\u25af\u25af\u25af0), or if the adjustment-free function is enabled (Pn170 = n.\u25af\u25af\u25af1), it must be set to &quot;Estimated Moment of Inertia.&quot; <br \/>\u2022 When executing in speed control mode, the mode selection must be set to 1. <\/p>\n<p>*1: STO is an optional feature. <\/p>\n<p>\u25a0Operation steps <br \/>1\u3001Confirm that the moment of inertia ratio has been set correctly (Pn103). <\/p>\n<p>2\u3001Connect the servo drive, and in the ProTuner [System Diagnostics] window, click the [Tuning] button in the workspace (see Figure 5). <\/p>\n<p>Alternatively, click the tuning shortcut button from the context menu in the [ProTuner] debugging window\uff08<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-014.png\" \/>\uff09\u3002 <\/p>\n<p>3\u3001In the [Tuning] window, click the [Execute] button (see Figure 6). <br \/>4\u3001Enter the [Tuning Axis] window (see Figure 7). <br \/>\u2022 Select the [Automatic Adjustment] group. <\/p>\n<p>\u2022 Choose [No Reference Input]. <\/p>\n<p>\u2022 Click the [Automatic Adjustment] button. <\/p>\n<p>5\u3001Enter the [Automatic Adjustment Setting Conditions] <\/p>\n<p>window (see Figure 8) and set the following: <\/p>\n<p>\u2022 [Switch Load Inertia (Load Quality) Estimation] field \u2022 [Mode Selection] field <br \/>\u2022 [Mechanism Selection] field <br \/>\u2022 [Distance] field <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\t\u2022 [Adjustment Parameters] field Then click\u3010Next\u3011 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-015.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-016.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-017.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Figure 5 <\/p>\n<\/td>\n<td>\n<p>Figure 6 <\/p>\n<\/td>\n<td>\n<p>Figure 7 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>\u2022 Select to switch load moment of inertia (load mass) estimation<br \/> 0\uff1aDo not estimate moving inertia [Factory Setting]  1\uff1aEstimate moving inertia<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-018.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022Mode Selection<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Mode <br \/>Selection<\/p>\n<\/td>\n<td>\n<p>illustrate <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1\uff1astandard<\/p>\n<\/td>\n<td>\n<p>Make standard gain adjustments. In addition to gain adjustment, notch filter and low-frequency resonance <br \/>suppression (Anti-resonance) are also automatically adjusted.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2\uff1aLocation<\/p>\n<\/td>\n<td>\n<p>Make positioning-specific adjustments. In addition to gain adjustment, model tracking control, notch filter, low-<br \/>frequency resonance suppression (Anti-resonance) and vibration suppression are also automatically adjusted.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3\uff1aLocation (Be careful not to <br \/>overshoot) <\/p>\n<\/td>\n<td>\n<p>Perform positioning-specific <br \/>adjustments (adjustments that focus on not overshooting). In addition to gain adjustment, notch filter, low-frequency resonance suppression (Anti-<br \/>resonance) and vibration suppression are also automatically adjusted.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022Institutional selection<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Institutional selection<\/p>\n<\/td>\n<td>\n<p>illustrate <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1\uff1aBelt drive mechanism <\/p>\n<\/td>\n<td>\n<p>Make adjustments suitable for low-rigidity mechanisms such as belt mechanisms.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2\uff1aBall screw mechanism or linear servo <br \/>mechanism <\/p>\n<\/td>\n<td>\n<p>Make adjustments suitable for highly rigid mechanisms such as ball screw mechanisms or linear servo motors. Please select this type if there is no corresponding organization.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3\uff1arigid body mechanism <\/p>\n<\/td>\n<td>\n<p>Make adjustments suitable for highly rigid mechanisms such as rigid body systems.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 Adjust parameters <br \/>Specify the tuning parameters to use. <\/p>\n<p>If the [Start adjustment with preset values] check box is checked, adjustment will be performed after the adjustment parameters are restored to the factory condition. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 distance <br \/>Set the moving distance. <\/p>\n<p>Movement range: -99990000 ~ +99990000 [reference unit] Minimum setting scale of moving distance: 1000 [reference unit] <br \/>Initial setting value: <br \/>Rotary servo motor approximately 3 turns <br \/>Direct drive servo motor approximately 0.3 turns <br \/>Linear servo motor about 90mm <br \/>Please set it to a value higher than the following value.In addition, to ensure adjustment accuracy, it is <br \/>recommended to set the movement distance around the initial setting value.\u3002 <\/p>\n<p>Rotary servo motor 0.5 turn <br \/>Direct drive servo motor 0.05 turn Linear servo motor 5mm<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>6\u3001Enter the [Auto Adjustment] window <\/p>\n<p>Click the [Servo On] button\uff08<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-019.png\" \/>\uff09\uff0cto energize the servo motor. <\/p>\n<p>Next, click the [Start Adjustment] button\uff08<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-020.png\" \/>\uff09\uff0cthe servo motor rotates and the adjustment is performed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-021.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-022.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-023.jpg\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-024.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-11\/sc3-sc3man-en-11-025.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Automatically detects vibration generated during adjustment and makes optimal settings for the generated vibration. After the setting is completed, the executed function box will light up. <\/p>\n<p>7\u3001After the adjustment is completed, click the [Finish] button to return to the [Tuning Axis] window. At this point, the operation of Automatic Adjustment (No Upper-Level Commands) is completed. <\/p>\n<p>Common Error Alarms <\/p>\n<p> 1.Error alarm when powering on for the first time [A.810] Encoder backup error alarm: <\/p>\n<p> Pn002\u3010Application Function Selections 2\u3011:\u25af1\u25af\u25af<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"4\">\n<p>n.\u25afX\u25af\u25af<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Encoder Usage<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Use the encoder according to encoder specifications.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Use the encoder as an incremental encoder.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Use the encoder as a single-turn absolute encoder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> 2.Error alarm when powering on for the first time [A.F10] The power line is missing a phase (in the Main Circuit PowerON state, one of the \t L1, L2, and L3 phases has a low voltage state that lasts for more than 1 second) <\/p>\n<p> Pn00b\u3010Application Function Selections B\u3011:\u25af1\u25af\u25af<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>n.\u25afX\u25af\u25af<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Power Input Selection for Three-phase SERVOPACK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Use a three-phase power supply input.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Use a three-phase power supply input as a single-phase power <br \/>supply input.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Common parameters\u3010X set parameter position\u3011<\/p>\n<p> 1.Motor Direction Change <\/p>\n<p> Pn000\u3010Basic Function Selections 0\u3011\uff1a0000\u3010Factory settings\u3011 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>n.\u25af\u25af\u25afX <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Movement Direction Selection<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Use CCW as the forward direction.\u3002<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Use CW as the forward direction. (Reverse Rotation Mode)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> 2.Rigid setting\uff08Pn100, Pn101, Pn102\uff09and Inertia setting\uff08Pn103\uff09 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Paramete r No.<\/p>\n<\/td>\n<td>\n<p>Size<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Setting Range<\/p>\n<\/td>\n<td>\n<p>Setting Unit<\/p>\n<\/td>\n<td>\n<p>\u51fa\u5ee0\u8a2d\u5b9a <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn100<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Speed Loop Gain<\/p>\n<\/td>\n<td>\n<p>10\uff5e20000<\/p>\n<\/td>\n<td>\n<p>0.1 Hz<\/p>\n<\/td>\n<td>\n<p>400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn101 <\/p>\n<\/td>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant<\/p>\n<\/td>\n<td>\n<p>15\uff5e51200 <\/p>\n<\/td>\n<td>\n<p>0.01 ms <\/p>\n<\/td>\n<td>\n<p>2000 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn102<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Position Loop Gain<\/p>\n<\/td>\n<td>\n<p>10\uff5e20000<\/p>\n<\/td>\n<td>\n<p>0.1\/s<\/p>\n<\/td>\n<td>\n<p>400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn103<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Moment of Inertia Ratio<\/p>\n<\/td>\n<td>\n<p>0 \uff5e20000<\/p>\n<\/td>\n<td>\n<p>1%<\/p>\n<\/td>\n<td>\n<p>100<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>3.Control filter selection <br \/>\tPn200\u3010Position Control Reference Form Selections\u3011\uff1a0000\u3010Factory settings\u3011 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"4\">\n<p>n.X\u25af\u25af\u25af<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Filter Selection<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Use the reference input filter for a line-driver signal. (1 Mpps max.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Use the reference input filter for an open-collector signal. (200 page 6-31 kpps max.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Use reference input filter 2 for a line-driver signal. (1 to 4 Mpps)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>4.Electronic gear ratio setting <br \/>Pn20E\u3010Electronic Gear Ratio(Numerator)\u3011:131072\u301017 Bit encoder\u3011\uff1b8388608\u301023Bit encoder\u3011 Pn210\u3010Electronic Gear Ratio(Denominator)\u3011:1000 <\/p>\n<p>5.Operation settings <br \/>Pn50A\u3010Input Signal Selections 1\u3011\uff1a <br \/>8881\u3010&quot;Forward rotation side can be driven&quot;; enable: power on enable\u3011 <br \/>0881\u3010&quot;Forward rotation side can be driven&quot;; enable\uff1aEnable forward drive when CN1-IN0 input signal is ON (closed).\u3011 Pn50B\u3010Input Signal Selections 2\u3011\uff1a 8889\u3010\u201cSet the signal to always prohibit forward drive.\u201d\u3011 <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chapter11.Tuning Software\uff08ProTuner\uff09 Using the host comp [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3306","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3306","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3306"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3306\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3306"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3306"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3306"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}