{"id":3307,"date":"2026-11-17T18:41:27","date_gmt":"2026-11-17T10:41:27","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-12\/"},"modified":"2026-11-17T18:41:27","modified_gmt":"2026-11-17T10:41:27","slug":"sc3-sc3man-en-12","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/sc3-sc3man-en-12\/","title":{"rendered":"Chapter 12 Tuning"},"content":{"rendered":"<h3>12.1 Overview and Flow of Tuning <\/h3>\n<p>Tuning is performed to optimize response by adjusting the servo gains in the servo driver. <\/p>\n<p>The servo gains are set using a combination of parameters, such as parameters for the speed loop gain, position loop gain, filters, friction compensation, and moment of inertia ratio. These parameters influence each other, so you must consider the balance between them. <\/p>\n<p>The servo gains are set to stable settings by default. Use the various tuning functions to increase the response even further for the conditions of your machine. <\/p>\n<p>The basic tuning procedure is shown in the following flowchart. Make suitable adjustments considering the conditions and operating requirements of your machine. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-001.png\" \/><\/p>\n<h4>12.1.1 Tuning Functions <br \/>\tThe following table provides an overview of the tuning functions. <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tuning Function <\/p>\n<\/td>\n<td>\n<p>Outline <\/p>\n<\/td>\n<td>\n<p>Applicable Con trol Methods <\/p>\n<\/td>\n<td>\n<p>Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Tuning-less Function <\/p>\n<\/td>\n<td>\n<p>This automatic adjustment function is designed to enable stable operation without servo tuning. This function can be used to obtain a stable response regardless of the type of machine or changes in the load. You can use it with the default settings.<\/p>\n<\/td>\n<td>\n<p>Speed control or position control <\/p>\n<\/td>\n<td>\n<p>Page 12-10 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Moment of Inertia Estimation <\/p>\n<\/td>\n<td>\n<p>The moment of inertia ratio is calculated by operat-ing the Servomotor a few times. <\/p>\n<p>The moment of inertia ratio that is calculated here is used in other tuning functions.<\/p>\n<\/td>\n<td>\n<p>Speed control, <br \/>position control, or torque control <\/p>\n<\/td>\n<td>\n<p>Page 12-13 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Autotuning without Host Reference <\/p>\n<\/td>\n<td>\n<p>The following parameters are automatically adjusted in the internal references in the servo driver during automatic operation. <\/p>\n<p>\u2022Gains (e.g., position loop gain and speed loop gain) \u2022Filters (torque reference filter and notch filters) <br \/>\u2022Friction compensation <br \/>\u2022Anti-resonance control <br \/>\u2022Vibration suppression <\/p>\n<\/td>\n<td>\n<p>Speed control or position control <\/p>\n<\/td>\n<td>\n<p>Page 12-20 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Autotuning with Host Reference <\/p>\n<\/td>\n<td>\n<p>The following parameters are automatically adjusted with the position reference input from the host controller while the machine is in operation. <\/p>\n<p>You can use this function for fine-tuning after you perform autotuning without a host reference. <\/p>\n<p>\u2022Gains (e.g., position loop gain and speed loop gain) \u2022Filters (torque reference filter and notch filters) <br \/>\u2022Friction compensation <br \/>\u2022Anti-resonance control <br \/>\u2022Vibration suppression <\/p>\n<\/td>\n<td>\n<p>Position control <\/p>\n<\/td>\n<td>\n<p>Page 12-29 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Custom Tuning <\/p>\n<\/td>\n<td>\n<p>The following parameters are adjusted with the position reference or speed reference input from the host controller while the <br \/>machine is in operation. <\/p>\n<p>\u2022Gains (e.g., position loop gain and speed loop gain) <\/p>\n<p>\u2022Filters (torque reference filter and notch filters) \u2022Friction compensation <br \/>\u2022Anti-resonance control <\/p>\n<\/td>\n<td>\n<p>Speed control or position control <\/p>\n<\/td>\n<td>\n<p>Page 12-36 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-resonance <br \/>ControlAdjustment<\/p>\n<\/td>\n<td>\n<p>This function effectively suppresses continuous vibration. <\/p>\n<\/td>\n<td>\n<p>Speed control or position control <\/p>\n<\/td>\n<td>\n<p>Page 12-44 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Suppression<\/p>\n<\/td>\n<td>\n<p>This function effectively suppresses residual vibra-tion if it occurs when positioning. <\/p>\n<\/td>\n<td>\n<p> Position control <\/p>\n<\/td>\n<td>\n<p>Page 12-47 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Additional <br \/>Adjustment Function <\/p>\n<\/td>\n<td>\n<p>This function combines autotuning with custom tuning. You can use it to improve adjustment results. <\/p>\n<\/td>\n<td>\n<p>Depends on the functions that you use. <\/p>\n<\/td>\n<td>\n<p>Page 12-51 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Manual Tuning <\/p>\n<\/td>\n<td>\n<p>You can manually adjust the servo gains to adjust the response. <\/p>\n<\/td>\n<td>\n<p>Speed control, <br \/>position control, or torque control<\/p>\n<\/td>\n<td>\n<p>Page 12-58 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.1.2 Diagnostic Tool <br \/>\tYou can use the following tools to measure the frequency characteristics of the machine and set notch filters. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Diagnostic Tool <\/p>\n<\/td>\n<td>\n<p>Outline <\/p>\n<\/td>\n<td>\n<p>Applicable Control Methods <\/p>\n<\/td>\n<td>\n<p>Reference<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Easy FFT <\/p>\n<\/td>\n<td>\n<p>The machine is subjected to vibration to detect resonance frequencies. The measurement results are displayed only as numeric data. <\/p>\n<\/td>\n<td>\n<p>Speed control, <br \/>position control, or torque control <\/p>\n<\/td>\n<td>\n<p>Page 12-74 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>12.2 Monitoring Methods <\/h3>\n<p>You can use the data tracing function of the ProTuner or the analog monitor signals of the servo driver for monitoring. If you perform custom tuning or manual tuning, always use the above functions to monitor the machine operating status and servo driver signal waveform while you adjust the servo gains. <\/p>\n<p>Check the adjustment results with the following response waveforms. <\/p>\n<p>\u2022 Position Control <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Item <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Unit <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rotary Servomotor <\/p>\n<\/td>\n<td>\n<p>Linear Servomotor <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Torque reference <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>% <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Feedback speed <\/p>\n<\/td>\n<td>\n<p>min-1<\/p>\n<\/td>\n<td>\n<p>mm\/s <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Position reference speed<\/p>\n<\/td>\n<td>\n<p>min-1<\/p>\n<\/td>\n<td>\n<p>mm\/s <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Position deviation <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Reference units <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022 Speed Control <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Item <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Unit <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rotary Servomotor<\/p>\n<\/td>\n<td>\n<p>Linear Servomotor <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Torque reference <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>% <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Feedback speed <\/p>\n<\/td>\n<td>\n<p>min-1<\/p>\n<\/td>\n<td>\n<p>mm\/s <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reference speed <\/p>\n<\/td>\n<td>\n<p>min-1<\/p>\n<\/td>\n<td>\n<p>mm\/s <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022 Torque Control <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Item <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Unit <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rotary Servomotor<\/p>\n<\/td>\n<td>\n<p>Linear Servomotor <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Torque reference <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>% <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Feedback speed <\/p>\n<\/td>\n<td>\n<p>min-1<\/p>\n<\/td>\n<td>\n<p>mm\/s <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-002.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-003.png\" \/><\/p>\n<h3>12.3 Precautions to Ensure Safe Tuning <\/h3>\n<p> CAUTION <br \/>Observe the following precautions when you perform tuning. <\/p>\n<p>\u2022 Do not touch the rotating parts of the motor when the servo is ON. <\/p>\n<p>\u2022 Before starting the Servomotor, make sure that an emergency stop can be performed at any time. \u2022 Make sure that trial operation has been successfully performed without any problems. <\/p>\n<p>\u2022 Provide an appropriate stopping device on the machine to ensure safety. <\/p>\n<p>Perform the following settings in a way that is suitable for tuning. <\/p>\n<h4>12.3.1 Overtravel Settings<\/h4>\n<p>Overtravel settings are made to force the Servomotor to stop for a signal input from a limit switch when a moving part of the machine exceeds the safe movement range. <\/p>\n<h4>12.3.2 Torque Limit Settings<\/h4>\n<p>You can limit the torque that is output by the Servomotor based on calculations of the torque required for machine operation. You can use torque limits to reduce the amount of shock applied to the machine when problems occur, such as collisions or interference. If the torque limit is lower than the torque that is required for operation, overshooting or vibration may occur. <\/p>\n<h4>12.3.3 Setting the Position Deviation Overflow Alarm Level<\/h4>\n<p>The position deviation overflow alarm is a protective function that is enabled when the servo driver is used in position control. If the alarm level is set to a suitable value, the servo driver will detect excessive position deviation and will stop the Servomotor if the Servomotor operation does not agree with the refer <br \/>ence. <\/p>\n<p>The position deviation is the difference between the position reference value and the actual position. <\/p>\n<p>You can calculate the position deviation from the position loop gain (Pn102) and the motor speed with the following formula. <\/p>\n<p>\u2022  Rotary Servomotors <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-004.png\" \/><\/p>\n<p>\u2022 Linear Servomotors<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-005.png\" \/><\/p>\n<p>Position Deviation Overflow Alarm Level (Pn520) [setting unit: reference units]<\/p>\n<p>\u2022 Rotary Servomotors<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-006.png\" \/><\/p>\n<p>*1. Refer to the following section for details. <\/p>\n<p>*2. When model following control (Pn140 = n.\u25af\u25af\u25af1) is enabled, use the setting of Pn141 (Model Following Control Gain) instead of the setting of Pn102 (Position Loop Gain). <\/p>\n<p>*3. To check the setting of Pn102 on the Digital Operator, change the parameter display setting to display all parameters (Pn00B = n.\u25af\u25af\u25af1). <\/p>\n<p>*4. The underlined coefficient \u201c\u00d7 (1.2 to 2)\u201d adds a margin to prevent an A.d00 alarm (Position Deviation Overflow) from occurring too frequently. <\/p>\n<p>If you set a value that satisfies the formula, an A.d00 alarm (Position Deviation Overflow) should not occur during normal operation. <\/p>\n<p>If the Servomotor operation does not agree with the reference, position deviation will occur, an error will be detected <\/p>\n<p>, and the Servomotor will stop. <\/p>\n<p>The following calculation example uses a Rotary Servomotor with a maximum motor speed of 6,000 and an encoder resolution of <\/p>\n<p>16,777,216 (24 bits).Pn102 is set to 400.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-007.png\" \/><\/p>\n<p>If the acceleration\/deceleration rate required for the position reference exceeds the tracking capacity of the Servomotor, the tracking delay will increase and the position deviation will no longer satisfy the above formulas. If this occurs, lower the acceleration\/deceleration rate so that the Servomotor can follow the position reference or increase the position deviation over-flow alarm level. <\/p>\n<p>Related Parameters <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn520 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Deviation Overflow Alarm Level <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 1073741823 <\/p>\n<\/td>\n<td>\n<p>1 reference unit<\/p>\n<\/td>\n<td>\n<p>5242880 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Related Alarms <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Alarm Number <\/p>\n<\/td>\n<td>\n<p>Alarm Name <\/p>\n<\/td>\n<td>\n<p>Alarm Meaning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d00 <\/p>\n<\/td>\n<td>\n<p>Position Deviation Overflow <\/p>\n<\/td>\n<td>\n<p>This alarm is displayed when the position deviation exceeds the set-ting of Pn520 (Position Deviation Overflow Alarm Level). <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.3.4 Vibration Detection Level Setting<\/h4>\n<p>You can set the vibration detection level (Pn312) to more accurately detect A.520 alarms (Vibration Alarm) and A.911 warnings (Vibration) <\/p>\n<p>when vibration is detected during machine operation. <\/p>\n<p>Set the initial vibration detection level to an appropriate value. Refer to the following section for details.<\/p>\n<h4>12.3.5 Setting the Position Deviation Overflow Alarm Level at Servo ON<\/h4>\n<p>If the servo is turned ON when there is a large position deviation, the Servomotor will attempt to return to the original position to bring the position deviation to 0, which may create a hazardous situation. To prevent this, you can set a position deviation overflow alarm level at servo ON to restrict operation. <\/p>\n<p>The related parameters and alarms are given in the following tables. <\/p>\n<p>Related Parameters <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn526 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Deviation Overflow Alarm Level at Servo ON <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 1073741823 <\/p>\n<\/td>\n<td>\n<p>1 reference unit<\/p>\n<\/td>\n<td>\n<p>5242880 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn528 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Deviation Overflow Warning Level at Servo ON <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn529 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Speed Limit Level at Servo ON <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>1min-1<\/p>\n<\/td>\n<td>\n<p>10000 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Related Alarms <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Alarm Number <\/p>\n<\/td>\n<td>\n<p>Alarm Name <\/p>\n<\/td>\n<td>\n<p>Alarm Meaning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d01 <\/p>\n<\/td>\n<td>\n<p>Position Deviation <br \/>Overflow Alarm at Servo ON <\/p>\n<\/td>\n<td>\n<p>This alarm occurs if the servo is turned ON after the position deviation exceeded the setting of Pn526 (Position Deviation Overflow Alarm Level at Servo ON) while the servo was OFF. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>A.d02 <\/p>\n<\/td>\n<td>\n<p>Position Deviation <br \/>Overflow Alarm for Speed Limit at Servo ON <\/p>\n<\/td>\n<td>\n<p>If position deviation remains in the deviation counter, the setting of Pn529 or Pn584 (Speed Limit Level at Servo ON) will limit the speed when the servo is turned ON. This alarm occurs if reference pulses are input and the setting of Pn520 (Position Deviation Overflow Alarm Level) is exceeded. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Refer to the following section for information on troubleshooting alarms. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-008.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-009.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-010.png\" \/><\/p>\n<h3>12.4 Tuning-less Function <\/h3>\n<p>The tuning-less function performs autotuning to obtain a stable response regardless of the type of machine or changes in the load. Autotuning is started when the servo is turned ON.<\/p>\n<p> CAUTION<\/p>\n<p>The tuning-less function is disabled during torque control. <\/p>\n<p>The Servomotor may momentarily emit a sound the first time the servo is turned ON after the Servomotor is connected to the machine. This sound is caused by setting the automatic notch filter. It does not indicate a problem. The sound will not be emitted from the next time the servo is turned ON. <\/p>\n<p>The Servomotor may vibrate if it exceeds the allowable load moment of inertia. <\/p>\n<p>If that occurs, set the tuning-less load level to 2 (Pn170 = n.2 \u25af\u25af\u25af) or reduce the tuningless rigidity level (Pn170 = n.\u25afX \u25af\u25af). To ensure safety, make sure that you can perform an emergency stop at any time when you execute the tuning-less function. <\/p>\n<h4>12.4.1 Application Restrictions<\/h4>\n<p>The following application restrictions apply to the tuning-less function. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>Executable *<\/p>\n<\/td>\n<td>\n<p>Remarks <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Detection Level Initialization <\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Moment of Inertia Estimation <\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>Disable the tuning-less function (Pn170 = n.\u25af\u25af\u25af0) before you execute moment of inertia estimation. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Autotuning without Host Reference <\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>Disable the tuning-less function (Pn170 = n.\u25af\u25af\u25af0) before you execute autotuning without a host reference. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Autotuning with Host Reference<\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Custom Tuning <\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-Resonance Control Adjustment<\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Suppression <\/p>\n<\/td>\n<td>\n<p>\u00d7 <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>EasyFFT <\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>The tuning-less function is disabled while you execute Easy FFT and then it is enabled when Easy FFT has been completed. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>*0: Yes  \u00d7: No<\/p>\n<h4>12.4.2 Operating Procedure<\/h4>\n<p>The tuning-less function is enabled in the default settings. No specific procedure is required. You can use the following parameter to enable or disable the tuning-less function. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Pn170 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0<\/p>\n<\/td>\n<td>\n<p>Disable tuning-less function. <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1 <br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Enable tuning-less function. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af0\u25af<br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Use for speed control. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>Use for speed control and use host controller for position control. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When you enable the tuning-less function, you can select the tuning-less type. Normally, set Pn14F to n.\u25af\u25af2 \u25af (Use tuning-less type 3) (default setting). <\/p>\n<p>If compatibility with previous models is required, set Pn14F to n.\u25af\u25af0 \u25af (Use tuning-less type 1) or n.\u25af\u25af1 \u25af (Use tuning-less type 2). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn14F <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af0\u25af<\/p>\n<\/td>\n<td>\n<p>Use tuning-less type 1. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Use tuning-less type 2. (The noise level is improved more than with tuning-less type 1.) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-011.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-012.png\" \/><\/p>\n<p>Tuning-less Level Settings <\/p>\n<p>If vibration or other problems occur, change the tuning-less levels. To change the tuning-less <\/p>\n<p>levels, use the Protuner.<\/p>\n<p>\u25c6\tPreparations <\/p>\n<p>Always check the following before you set the tuning-less levels. <\/p>\n<p>\u2022 The tuning-less function must be enabled (Pn170 = n.\u25af\u25af\u25af1). <\/p>\n<p>\u25c6\tProcedure <\/p>\n<p>Use the following procedure to set the tuning-less levels. <\/p>\n<p>In addition to the following procedure, you can also set the parameters directly. Refer to Related Parameters, below, <\/p>\n<p>for the parameters to set. <\/p>\n<p><strong>1. <\/strong>Select from the menu bar on the Protuner main screen [Setup] \uff0d [Response Level Setting]\u3002 <\/p>\n<p>Setting [Response Level Setting] in the Menu Dialog Box. <\/p>\n<p><strong>2. <\/strong>Click the [ \u25b2 ] or [ \u25bc ] Button to adjust the tuning-less level setting. Increase the tuning-less level setting to increase <\/p>\n<p>the response. Decrease the tuning-less level setting to suppress vibration. The default response level setting is 4.<\/p>\n<p>Tuning-less Level \tDescription <\/p>\n<p>\u201c7\u201d \tResponselevel:High <\/p>\n<p>\u201c6\u201d <\/p>\n<p>\u201c5\u201d <\/p>\n<p>\u201c4\u201d[default setting ] <\/p>\n<p>\u201c3\u201d <\/p>\n<p>\u201c2\u201d <\/p>\n<p>\u201c1\u201d Response level: Low <\/p>\n<p><strong>3. <\/strong>Click the Completed Button. <\/p>\n<p>The adjustment results will be saved in the servo driver. <\/p>\n<p>\u25c6\tRelated Parameters <\/p>\n<p>\u25a0Tuning-less Rigidity Level <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"9\">\n<p>Pn170 <\/p>\n<\/td>\n<td>\n<p>Parameter <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Description <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af0\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 0 (low rigidity) <\/p>\n<\/td>\n<td rowspan=\"8\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"8\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning-less rigidity level 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af2\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af3\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>n.\u25af4\u25af\u25af<br \/>[default setting ]Tuning-less rigidity level 4<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af5\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af6\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af7\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less rigidity level 7 (high rigidity) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25a0Tuning-less Load Level <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Description <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn170 <\/p>\n<\/td>\n<td>\n<p>n.0\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less load level 0<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.1\u25af\u25af\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Tuning-less load level 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.2\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Tuning-less load level 2<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.4.3 Troubleshooting Alarms <br \/>An A.521 alarm (Autotuning Alarm) will occur if a resonant sound occurs or if excessive vibration occurs during position control. If an alarm occurs, implement the following measures. <\/p>\n<p>\u2022 Resonant Sound <br \/>\tDecrease the setting of Pn170 = n.X \u25af\u25af\u25af or the setting of Pn170 = n.\u25afX \u25af\u25af. <\/p>\n<p>\u2022 Excessive Vibration during Position Control <br \/>\tIncrease the setting of Pn170 = n.X \u25af\u25af\u25af or decrease the setting of Pn170 = n.\u25afX \u25af\u25af. <\/p>\n<h4>12.4.4 Parameters Disabled by Tuning-less Function<\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item <\/p>\n<\/td>\n<td>\n<p>Parameter Name <\/p>\n<\/td>\n<td>\n<p>Parameter Number <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Gain-Related Parameters<\/p>\n<\/td>\n<td>\n<p>Speed Loop Gain <br \/>Second Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Pn100 Pn104 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Loop Integral Time Constant <br \/>Second Speed Loop Integral Time Constant<\/p>\n<\/td>\n<td>\n<p>Pn101 Pn105 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Position Loop Gain <br \/>Second Position Loop Gain <\/p>\n<\/td>\n<td>\n<p>Pn102 Pn106 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Moment of Inertia Ratio <\/p>\n<\/td>\n<td>\n<p>Pn103 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Advanced Control-Related arameters <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Control Selection <\/p>\n<\/td>\n<td>\n<p>Pn160= n.\u25af\u25af\u25afX <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The tuning-less function is disabled during torque control, Easy FFT, and mechanical analysis for a vertical axis. The gain-related parameters in the above table are enabled for torque control, Easy FFT, and mechanical analysis. Of these, Pn100, Pn103, and Pn104 are enabled for torque control.<\/p>\n<h4>12.4.5 Automatically Adjusted Function Setting<\/h4>\n<p>You can also automatically adjust notch filters. <\/p>\n<p>Normally, set Pn460 to n.\u25af1 \u25af\u25af (Adjust automatically) (default setting). Vibration is automatically detected and a notch filter is set. Set Pn460 to n.\u25af0 \u25af\u25af (Do not adjust automatically) only if you do not change the setting of the notch filter before you execute the tuning-less function. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn460 <\/p>\n<\/td>\n<td>\n<p>n.\u25af0\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Do not adjust the second stage notch filter <br \/>automatically when the tuning-less function is enabled or during execution of autotuning <br \/>without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<br \/>[default setting] <\/p>\n<\/td>\n<td>\n<p>Adjust the second stage notch filter automati cally when the tuning-less function is enabled or during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.4.6 Related Parameters<\/h4>\n<p>The following parameters are automatically adjusted when you execute the tuning-less function. Do not manually change the settings of these parameters after you have enabled the tuning-less function. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn401 <\/p>\n<\/td>\n<td>\n<p>First Stage First Torque Reference Filter Time Constant <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40C <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Frequency <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40D <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Q Value <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>12.5 Estimating the Moment of Inertia <\/h3>\n<p>This section describes how the moment of inertia is calculated. <\/p>\n<p>The moment of inertia ratio that is calculated here is used in other tuning functions. You can also estimate the moment of inertia during autotuning without a host reference. Refer to the following section for the procedure. <\/p>\n<h4>12.5.1 Outline <\/h4>\n<p>The moment of inertia during operation is automatically calculated by the servo driver for round-trip forward and reverse) operation. A reference from the host controller is not used. <\/p>\n<p>The moment of inertia ratio (i.e., the ratio of the load moment of inertia to the motor moment of inertia) is a basic parameter for adjusting gains. It must be set as accurately as possible.Although the load moment of inertia can be calculated from the weight and structure of the mechanisms, doing so is very troublesome and calculating it accurately can be very difficult with the complex mechanical structures that are used these days. With moment of inertia estimation, you can get an accurate load moment of inertia simply by operating the Servomotor in the actual system in forward and reverse a few times. <\/p>\n<p>The Servomotor is operated with the following specifications. <\/p>\n<p>\u2022 Maximum speed: \u00b11,000 min-1 (can be changed) <\/p>\n<p>\u2022 Acceleration rate: \u00b120,000 min-1\/s (can be changed) <\/p>\n<p>\u2022 Travel distance: \u00b12.5 rotations max. (can be changed) <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-013.png\" \/><\/p>\n<p>NOTE: Execute moment of inertia estimation <br \/>after jogging to a position that ensures a <br \/>suitable range of motion.<\/p>\n<h4>12.5.2 Restrictions<\/h4>\n<p>The following restrictions apply to estimating the moment of inertia. <\/p>\n<p>Systems for which Execution Cannot Be Performed <\/p>\n<p>\u2022 When the machine system can move only in one direction <\/p>\n<p>\u2022 When the range of motion is 0.5 rotations or less <\/p>\n<p>Systems for Which Adjustments Cannot Be Made Accurately <\/p>\n<p>\u2022 When a suitable range of motion is not possible <\/p>\n<p>\u2022 When the moment of inertia changes within the set operating range <\/p>\n<p>\u2022 When the machine has high dynamic friction <\/p>\n<p>\u2022 When the rigidity of the machine is low and vibration occurs when positioning is performed <\/p>\n<p>\u2022 When the position integration function is used <\/p>\n<p>\u2022 When proportional control is used <\/p>\n<p>NOTE:If you specify calculating the moment of inertia, an error will occur if the \/P-CON (Proportional Control) signal changes to specify the <\/p>\n<p>proportional action during moment of inertia estimation <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-014.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-015.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-016.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-017.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-018.png\" \/><\/p>\n<p>\u2022 When mode switching is used <\/p>\n<p>NOTE:If you specify moment of inertia estimation, mode switching will be disabled and PI control will be used while the moment of \tinertia is being calculated. Mode switching will be enabled after moment of inertia estimation has been completed. <\/p>\n<p>\u2022 When speed feedforward or torque feedforward is input <\/p>\n<p>Preparations <\/p>\n<p>Always check the following before you execute moment of inertia estimation. <\/p>\n<p>\u2022 The main circuit power supply must be ON. <\/p>\n<p>\u2022 There must be no overtravel. <\/p>\n<p>\u2022 The servo must be OFF. <\/p>\n<p>\u2022 The control method must not be set to torque control. <\/p>\n<p>\u2022 The gain selection switch must be set to manual gain selection (Pn139 = n.\u25af\u25af\u25af0). \u2022 The first gains must be selected. <\/p>\n<p>\u2022 There must be no alarms or warnings. <\/p>\n<p>\u2022 There must be no hard wire base block (HWBB). <\/p>\n<p>\u2022 The parameters must not be write prohibited.<\/p>\n<p>\u2022 The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0). <\/p>\n<h4>12.5.3 Applicable Tools<\/h4>\n<p>The following table lists the tools that you can use to estimate the moment of inertia. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>You cannot estimate the moment of inertia from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d[Tuning] <\/p>\n<\/td>\n<td>\n<p> Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.5.4 Operating Procedure<\/h4>\n<p> Use the following procedure to estimate the moment of inertia ratio. <\/p>\n<p> WARNING<\/p>\n<p>Estimating the moment of inertia requires operating the Servomotor and therefore presents hazards. Observe the <\/p>\n<p>following precautions. <\/p>\n<p>\u2022Confirm safety around moving parts. <\/p>\n<p>This function involves automatic operation with vibration. Make sure that you can perform an emergency stop (to turn OFF the power supply) at any time. There will be movement in both directions within the set range of movement. Check the range of movement and the directions and implement protective controls for safety, such as the overtravel functions.\u3002<\/p>\n<p> CAUTION<\/p>\n<p>Be aware of the following points if you cancel the moment of inertia estimation while the Servomotor is operating. \u2022If you cancel operation with the Servo OFF Button, the Servomotor will stop according to setting of the Servo OFF stopping method (Pn001 = n.\u25af\u25af\u25afX). <\/p>\n<p>\u2022If you cancel operation with the Cancel Button, the Servomotor will decelerate to a stop and then enter a \tzero-clamped state.<\/p>\n<p><strong>1. <\/strong>Select Tuning in the Menu Dialog Box. <\/p>\n<p>The Tuning Dialog Box will be displayed.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-019.jpg\" \/><\/p>\n<p><strong>2. <\/strong>Click the OK Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-020.jpg\" \/><\/p>\n<p><strong>3. <\/strong>Click the Execute Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-021.jpg\" \/><\/p>\n<p><strong>4. <\/strong>Set the conditions as required. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-022.jpg\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-023.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-024.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-025.png\" \/><\/p>\n<p>(1) [Speed Loop Setting] <br \/>Make the speed loop settings in this area. <\/p>\n<p>If the speed loop response is too bad, it will not be possible to measure the moment of inertia ratio accurately. <\/p>\n<p>The values for the speed loop response that are required for moment of inertia estimation are set for the default settings. It is normally not necessary to change these settings. If the default speed loop gain is too high for the machine (i.e., if vibration occurs), lower the setting. It is not necessary to increase the setting any farther. <\/p>\n<p>(2) [Identification Start Level] <br \/>This is the setting of the moment of inertia calculation starting level. <\/p>\n<p>If the load is large or the machine has low rigidity, the torque limit may be applied, caus-ing moment of inertia estimation to fail. If that occurs, estimation may be possible if you double the setting of the start level. <\/p>\n<p>(3) [Reference Selection] <\/p>\n<p>Either select the reference pattern for estimation processing from the box, or set the val-ues in the Detailed Setting Group. Generally speaking, the larger the maximum acceler-ation rate is, the more accurate the moment of inertia estimation will be. <\/p>\n<p>Set the maximum acceleration range within the possible range of movement considering the gear ratio, e.g., the pulley diameters or ball screw pitch. <\/p>\n<p>(4) [Confirm] <\/p>\n<p>Click this button to display the Reference Confirmation Dialog Box.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-026.jpg\" \/><\/p>\n<p>(5) [Detailed Setting] <br \/>You can change the settings by moving the bars or directly inputting the settings to cre-ate the required reference pattern. <\/p>\n<p>(6) [Next] <\/p>\n<p>(7) [Cancel] <\/p>\n<p>Click this button to return to the Tuning Dialog Box. <\/p>\n<p> CAUTION<\/p>\n<p>The travel distance is the distance for one operation in the forward or reverse direction. During multiple operations, the operation starting position may move in one direction or the other. Confirm the possible operating range for each measurement or operation. <\/p>\n<p>Depending on the parameter settings and the moment of inertia of the machine, overshooting and undershooting may occur and may cause the maximum speed setting to be exceeded temporarily. Allow sufficient leeway in the settings. <\/p>\n<p> NOTE: Estimating the moment of inertia ratio cannot be performed correctly if the torque limit is activated. Adjust the limits or  \treduce the acceleration rate in the reference selection so that the torque limit is not activated.\u3002 <\/p>\n<p><strong>5. <\/strong>Click the Next Button. <\/p>\n<p>The Reference Transmission Dialog Box will be displayed. <\/p>\n<p><strong>6. <\/strong>Click the Start Button <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-027.jpg\" \/><\/p>\n<p>(1) [Start] <br \/>The reference conditions will be transferred to the servo driver. A progress bar will show the progress of the transfer. <\/p>\n<p>(2) [Cancel] <br \/>The Cancel Button is enabled only while data is being transferred to the servo driver. You cannot use it after the transfer has been completed. <\/p>\n<p>(3) [Back] <br \/>\tThis button returns you to the Condition Setting Dialog Box. It is disabled while data is being transferred. <\/p>\n<p>(4) [Next] <br \/>This button is enabled only when the data has been transferred correctly. You cannot use it if an error occurs or if you cancel the transfer before it is completed. <\/p>\n<p>Click the Next Button to display the Operation\/Measurement Dialog Box.\u3002 <\/p>\n<p>(5) [Cancel] <br \/>\tThis button cancels processing and returns you to the Tuning Dialog Box. <\/p>\n<p><strong>7. <\/strong>Click the Next Button. <\/p>\n<p>The Operation\/Measurement Dialog Box will be displayed. <\/p>\n<p><strong>8. <\/strong>Click the Servo On Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-028.jpg\" \/><\/p>\n<p><strong>9. <\/strong>Click the Forward Button. <\/p>\n<p>The Servomotor shaft will rotate in the forward direction and the measurement will start. <\/p>\n<p><strong>10. <\/strong>Click the Reverse Button. <\/p>\n<p>The Servomotor shaft will rotate in the reverse direction and the measurement will start. After the measurement and data <\/p>\n<p>transfer have been completed, the Forward Button will be displayed in color. <\/p>\n<p><strong>11. <\/strong>Repeat steps 8 to 9 until the Next Button is enabled. <\/p>\n<p>Measurements are performed from 2 to 7 times and then verified. The number of measurements is displayed in upper left <\/p>\n<p>corner of the dialog box. <\/p>\n<p><strong>12. <\/strong>When the measurements have been completed, click the Servo On Button to turn OFFthe servo. <\/p>\n<p><strong>13. <\/strong>Click the Next Button. <\/p>\n<p>The Write Results Dialog Box will be displayed. <\/p>\n<p><strong>14. <\/strong>Click the Writing Results Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-029.jpg\" \/><\/p>\n<p>(1)[Identified Moment of Inertia Ratio] <br \/>\tThe moment of inertia ratio that was found with operation and measurements is dis-played here. <\/p>\n<p>(2) [Writing Results] <br \/>If you click this button, Pn103 (Moment of Inertia Ratio) in the servo driver is set to the value that is displayed for the identified moment of inertia ratio. <\/p>\n<p>(3) [Pn103: Moment of Inertia Ratio Box] <br \/>\tThe value that is set for the parameter is displayed here. <\/p>\n<p>After you click the Writing Results Button, the value that was found with operation andmeasurements will be displayed as the new setting.\u3002 <\/p>\n<p>(4)[Finish] <\/p>\n<p>(5) [Cancel] <\/p>\n<p>This button will return you to the Tuning Dialog Box. <\/p>\n<p><strong>15. <\/strong>Confirm that the Identified Moment of Inertia Ratio Box and the Pn103: Moment of Inertia Ratio Box show the \tsame value and then click the Finish Button. <\/p>\n<p><strong>16. <\/strong>Click the Execute Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-030.jpg\" \/><\/p>\n<p>If the setting of the moment of inertia ratio (Pn103) was changed, the new value will be saved and the Tuning Dialog <\/p>\n<p>Box will be displayed again.\u3002 <\/p>\n<h3>12.6 Autotuning without Host Reference <\/h3>\n<p>This section describes autotuning without a host reference. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-031.png\" \/><\/p>\n<\/td>\n<td>\n<p>\u2022 Autotuning without a host reference performs adjustments based on the setting of the speed loop gain (Pn100). Therefore, <\/p>\n<p>precise adjustments cannot be made if there is vibration when adjustments are started. Make adjustments after lowering <\/p>\n<p>the speed loop gain (Pn100) until vibration is eliminated. <\/p>\n<p>\u2022 You cannot execute autotuning without a host reference if the tuning-less function is enabled <\/p>\n<p>(Pn170 = n.\u25af\u25af\u25af1 (default setting)). Disable the tuning-less function (Pn170 = n.\u25af\u25af\u25af0) before you execute <\/p>\n<p>autotuning without a host reference. <\/p>\n<p>\u2022 If you change the machine load conditions or drive system after you execute autotuning without a host reference and then you execute autotuning without a host reference with moment of inertia estimation specified, use the following parameter settings. If you execute autotuning without a host reference for any other conditions, the machine may vibrate and may be dam-aged. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\tPn140 = n.\u25af\u25af\u25af0 (Do not use model following control.) <br \/>\tPn160 = n.\u25af\u25af\u25af0 (Do not use anti-resonance control.) <br \/>\tPn408 = n.00 \u25af0 (Disable friction compensation, first stage notch filter, and second stage <br \/>\tnotch filter.) <br \/>NOTE: If you are using the Digital Operator and the above parameters are not displayed, change the parameter display \t\tsetting to display all parameters (Pn00B = n. \t1) and then turn the power supply OFF and ON again.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.6.1 Outline <\/h4>\n<p>The following items are adjusted automatically. <\/p>\n<p>\u2022 Moment of inertia ratio <br \/>\u2022 Gains (e.g., speed loop gain and position loop gain) <br \/>\u2022 Filters (torque reference filter and notch filters) <br \/>\u2022 Friction compensation <br \/>\u2022 Anti-resonance control<br \/>\u2022 Vibration suppression (only for mode 2 or 3) <\/p>\n<p>The Servomotor is operated with the following specifications. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Maximum speed<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Rated motor speed \u00d7 2\/3 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Acceleration Torque <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Rated motor torque: Approx. 100% <br \/>NOTE: The acceleration torque depends on the setting of the moment of inertia ratio \t(Pn103), and the influences of machine friction and external disturbance.\u3002 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Travel Distance <\/p>\n<\/td>\n<td>\n<p>Rotary Servomotors <\/p>\n<\/td>\n<td>\n<p>You can set the desired travel distance. The default setting is for a value equivalent to 3 Servomotor shaft rotations. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Direct Drive Servomotors <\/p>\n<\/td>\n<td>\n<p>You can set the desired travel distance. The default setting is for a value equivalent to 0.3 rotations. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-032.png\" \/><\/p>\n<p>NOTE: Execute autotuning without a host reference after jogging to <br \/>\ta position that ensures a suitable range of motion.\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-033.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-034.png\" \/><\/p>\n<p> WARNING<\/p>\n<p>Autotuning without a host reference requires operating the Servomotor and therefore presents hazards. <\/p>\n<p> Observe the following precaution. <\/p>\n<p>\u2022Confirm safety around moving parts. <\/p>\n<p>This function involves automatic operation with vibration. Make sure that you can perform an emergency stop (to turn OFF the power supply) at any time. There will be movement in both directions within the set range of movement. Check the range of movement and the directions and implement protective controls for safety, such as the overtravel functions. <\/p>\n<h4>12.6.2 Restrictions <\/h4>\n<p>The following restrictions apply to autotuning without a host reference. <\/p>\n<p>Systems for Which Execution Cannot Be Performed <\/p>\n<p>\u2022 When the machine system can move only in one direction <\/p>\n<p>\u2022 When the range of motion is 0.5 rotations or less <\/p>\n<p>Systems for Which Adjustments Cannot Be Made Accurately <br \/>\u2022 When a suitable range of motion is not possible <br \/>\u2022 When the moment of inertia changes within the set operating range <br \/>\u2022 When the machine has high friction <br \/>\u2022 When the rigidity of the machine is low and vibration occurs when positioning is performed \u2022 When the position integration function is used <br \/>\u2022 When proportional control is used<\/p>\n<p>NOTE: If you specify calculating the moment of inertia, an error will occur if the \/P-CON (Proportional Control) signal changes to specify \tthe proportional action during moment of inertia estimation. <\/p>\n<p>\u2022 When mode switching is used <\/p>\n<p>NOTE:If you specify moment of inertia estimation, mode switching will be disabled and PI control will be used while the moment of inertia is being calculated. Mode switching will be enabled after moment of inertia estimation has been completed.\u3002 <\/p>\n<p>\u2022 When speed feedforward or torque feedforward is input <br \/>\u2022 When the positioning completed width (Pn522) is too narrow <\/p>\n<p>Preparations <\/p>\n<p>Always check the following before you execute autotuning without a host reference. <\/p>\n<p>\u2022 The main circuit power supply must be ON. <\/p>\n<p>\u2022 There must be no overtravel. <\/p>\n<p>\u2022 The servo must be OFF <br \/>\u2022 The control method must not be set to torque control. <\/p>\n<p>\u2022 The gain selection switch must be set to manual gain selection (Pn139 = n.\u25af\u25af\u25af0). <\/p>\n<p>\u2022 The first gains must be selected. <\/p>\n<p>\u2022 There must be no alarms or warnings. <\/p>\n<p>\u2022 There must be no hard wire base block (HWBB). <\/p>\n<p>\u2022 The parameters must not be write prohibited.\u201d <br \/>\u2022 The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0), or the tuning-less function must be enabled (Pn170 = n.\u25af\u25af\u25af1) (default setting) and moment of inertia estimation must be specified. \u201d <\/p>\n<p>\u2022 If you execute autotuning without a host reference during speed control, set the mode to 1.<\/p>\n<p>NOTE: If you start autotuning without a host reference while the servo driver is in speed control for mode 2 or 3, the servo driver will change to position control automatically to perform autotuning without a host reference. The servo driver will return to speed control after autotuning has been completed.\u3002 <\/p>\n<p> Reference pulse input multiplication switching is disabled during autotuning without a host reference.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-035.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-036.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-037.png\" \/><\/p>\n<h4>12.6.3 Applicable Tools <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<td>\n<p>You cannot perform autotuning without a host reference from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital Operator <\/p>\n<\/td>\n<td>\n<p>Fn201 <\/p>\n<\/td>\n<td>\n<p>Operator Operating Manual<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d [Tuning] <\/p>\n<\/td>\n<td>\n<p>Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.6.4 Operating Procedure<\/h4>\n<p>Use the following procedure to perform autotuning without a host reference. <\/p>\n<p> CAUTION <br \/>If you specify not estimating the moment of inertia, set the moment of inertia ratio (Pn103) correctly. If the setting greatly differs from the actual moment of inertia ratio, normal control of the machine may not be possible, and vibration may result.\u3002<\/p>\n<p>If you are using a SC3 If you are using a\uff0cset the mode selection to 1. If 2 or 3 is selected for the mode, correct phase control may not be possible. <\/p>\n<p><strong>1. <\/strong>Confirm that the moment of inertia ratio (Pn103) is set correctly. <\/p>\n<p><strong>2. <\/strong>Select Tuning in the Menu Dialog Box. <\/p>\n<p>The Tuning Dialog Box will be displayed. <\/p>\n<p>Click the Cancel Button to cancel tuning. <\/p>\n<p><strong>3. <\/strong>Click the OK Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-038.jpg\" \/><\/p>\n<p><strong>4. <\/strong> Select the No Reference Input Option in the Autotuning Area and then click the Auto-tuning Button.\u3002 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-039.jpg\" \/><\/p>\n<p><strong>5. <\/strong>Set the conditions in the Switching the load moment of inertia (load mass) identifica-tion Box, the Mode selection \tBox,the Mechanism selection Box, and the Distance Box, and then click the Next Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-040.jpg\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-041.png\" \/><\/p>\n<p><strong>6. <\/strong>Click the Servo ON Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-042.jpg\" \/><\/p>\n<p><strong>7. <\/strong>Click the Start tuning Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-043.jpg\" \/><\/p>\n<p>The Servomotor will start operating and tuning will be executed. <\/p>\n<p>When the settings have been completed, the indicators for the functions that were used will light at the lower left of the dialog box.<\/p>\n<p><strong>8. <\/strong>When tuning has been completed, click the Finish Button. <\/p>\n<p>The results of tuning will be set in the parameters and you will return to the Tuning Dialog Box. <\/p>\n<p>This concludes the procedure to perform autotuning without a host reference. <\/p>\n<h4>12.6.5 Troubleshooting Problems in Autotuning without a Host Reference<\/h4>\n<p>The following tables give the causes of and corrections for problems that may occur in autotuning without a host reference. Autotuning without a Host Reference Was Not Performed<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Corrective Action <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Main circuit power supply is OFF.<\/p>\n<\/td>\n<td>\n<p>Turn ON the main circuit power supply. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An alarm or warning occurred. <\/p>\n<\/td>\n<td>\n<p>Remove the cause of the alarm or warning. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Overtraveling occurred. <\/p>\n<\/td>\n<td>\n<p>Remove the cause of overtraveling. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The second gains were selected with the gain selection. <\/p>\n<\/td>\n<td>\n<p>Disable automatic gain switching. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The HWBB was activated.<\/p>\n<\/td>\n<td>\n<p>Release the HWBB. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The setting of the travel distance is too small. <\/p>\n<\/td>\n<td>\n<p>Set the travel distance again in step 6 of the procedure. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The settings for the tuning-less function are not correct. <\/p>\n<\/td>\n<td>\n<p>\u2022 Disable the tuning-less function (Pn170 = n.\u25af\u25af\u25af0). \u2022 Enable the tuning-less function (Pn170 = n.\u25af\u25af\u25af1) and \tspecify moment of inertia estimation. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When an Error Occurs during Execution of Autotuning without a Host Reference <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Error <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Corrective Action <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The gain adjustments were not successfully completed. <\/p>\n<\/td>\n<td>\n<p>Machine vibration occurs or the positioning <br \/>completion signal is not stable when the <br \/>Servomotor stops. <\/p>\n<\/td>\n<td>\n<p>\u2022 Increase the setting of the positioning completed width (Pn522). <\/p>\n<p>\u2022 Change the mode from 2 to 3. <\/p>\n<p>\u2022 If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment and the vibration suppression function. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An error occurred during calculation of the moment of inertia. <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Refer to the following section for troubleshooting information. \tWhen an Error Occurs during Calculation of Moment of Inertia <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Positioning was not completed within approximately 10 seconds after position adjustment was completed. <\/p>\n<\/td>\n<td>\n<p>The positioning completed width is too narrow or <br \/>proportional control is being used. <\/p>\n<\/td>\n<td>\n<p>\u2022 Increase the setting of the positioning completed width (Pn522). <\/p>\n<p>\u2022 Turn OFF the \/P-CON (Proportional Control) signal. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When an Error Occurs during Calculation of Moment of Inertia<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Corrective Action <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The servo driver started calculating the moment of inertia but the calculation was not completed. <\/p>\n<\/td>\n<td>\n<p>\u2022 Increase the setting of the speed loop gain (Pn100). \u2022 Increase the stroke (travel distance). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The moment of inertia fluctuated greatly and did not converge within 10 tries. <\/p>\n<\/td>\n<td>\n<p>Set Pn103 (Moment of Inertia Ratio) from the machine specifications and specify not estimating the moment of inertia. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Low-frequency vibration was detected. <\/p>\n<\/td>\n<td>\n<p>Double the setting of moment of inertia calculation starting level (Pn324). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The torque limit was reached. <\/p>\n<\/td>\n<td>\n<p>\u2022 If you are using the torque limit, increase the torque limit. <\/p>\n<p>\u2022 Double the setting of moment of inertia calculation starting level \t(Pn324). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The speed control section changed to <br \/>proportional control during calculation of the moment of inertia, e.g., the \/P-CON <br \/>(Proportional Control) signal was input. <\/p>\n<\/td>\n<td>\n<p>Use PI control when calculating the moment of inertia. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Adjustment Results Are Not Satisfactory for Position Control <br \/>You may be able to improve the adjustment results by changing the settings of the positioning completed width (Pn522) and the electronic gear ratio (Pn20E\/Pn210). <\/p>\n<p>\u2022 Pn561 = 100% (default setting) <br \/>\u2022 This will allow tuning with overshooting that is equivalent to the positioning completed width.<\/p>\n<p>\u2022 Pn561 = 0% <br \/>\tThis will allow tuning to be performed without overshooting within the positioning completed width. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn561 <\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Overshoot Detection Level<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>When En<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>ab<\/p>\n<\/td>\n<td>\n<p>Pos<\/p>\n<\/td>\n<td>\n<p>ition<\/p>\n<\/td>\n<td>\n<p>ss<\/p>\n<\/td>\n<td>\n<p>Torque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>led <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Classification <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.6.6 Automatically Adjusted Function Settings<\/h4>\n<p>You can specify whether to automatically adjust the following functions during autotuning. \u25c6Automatic Notch Filters<\/p>\n<p>Normally, set Pn460 to n.\u25af1 \u25af\u25af (Adjust automatically) (default setting). <\/p>\n<p>Vibration will be detected during autotuning without a host reference and a notch filter will be adjusted. Set Pn460 to n.\u25af0 \u25af\u25af (Do not adjust automatically) only if you do not change the setting of the notch filter before you execute this function. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Pn460 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0<\/p>\n<\/td>\n<td>\n<p>Do not adjust the first stage notch filter auto matically during execution of autotuning with out a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1 <br \/>[default setting] <\/p>\n<\/td>\n<td>\n<p>Adjust the first stage notch filter <br \/>automatically during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af0\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Do not adjust the second stage notch filter automatically when the tuning-less function is enabled or during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<br \/>[default setting] <\/p>\n<\/td>\n<td>\n<p>Adjust the second stage notch filter <br \/>automatically when the tuning-less function is enabled or during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Control Adjustment <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>This function reduces low vibration frequencies, for which the notch filters cannot be used. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Normally, set Pn160 to n.\u25af\u25af1 \u25af (Adjust automatically) (default setting). <\/p>\n<p>Vibration will be detected during autotuning without a host reference and anti-resonance control will be automatically adjusted.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn160 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af0\u25af<\/p>\n<\/td>\n<td>\n<p>Do not adjust anti-resonance control <br \/>automatically during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Adjust anti-resonance control automatically during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Vibration Suppression <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>You can use vibration suppression to suppress transitional vibration at a low frequency from 1 Hz to 100 Hz, which is generated mainly when the machine vibrates during positioning. <\/p>\n<p>Normally, set Pn140 to n.\u25af1 \u25af\u25af (Adjust automatically) (default setting). Vibration will be detected during autotuning without a host reference and vibration suppression control will be automatically set. <\/p>\n<p>Set Pn140 = n.\u25af0 \u25af\u25af (Do not adjust automatically) only if you do not change the settings for vibration suppression before you execute autotuning without a host reference. <\/p>\n<p>NOTE: Autotuning without a host reference uses model following control. Therefore, it can be executed only if the mode is set to 2 or 3.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>n.\u25af0\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Do not adjust vibration suppression <br \/>automatically during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<br \/>[default setting ] <\/p>\n<\/td>\n<td>\n<p>Adjust vibration suppression automatically during execution of autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-044.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-045.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-046.png\" \/><\/p>\n<p>\u25c6\tFriction Compensation <\/p>\n<p>Friction compensation compensates for changes in the following conditions. <\/p>\n<p>\u2022 Changes in the viscous resistance of the lubricant, such as grease, on the sliding parts of the machine <\/p>\n<p>\u2022 Changes in the friction resistance resulting from variations in the machine assembly <\/p>\n<p>\u2022 Changes in the friction resistance due to aging <\/p>\n<p>The conditions for applying friction compensation depend on the mode selection. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Mode Selection Settings <\/p>\n<\/td>\n<td>\n<p>Friction Compensation <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1\uff1aStandard <\/p>\n<\/td>\n<td>\n<p>Based on the setting of Pn408 = n.X\u25af\u25af\u25af (Friction Compensation Function Selection)* <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2\uff1aFor position control <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Adjusted with friction compensation. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3\uff1aFor position control (emphasis on overshooting) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn408 <\/p>\n<\/td>\n<td>\n<p>n.0\u25af\u25af\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Disable friction compensation. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.1\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Enable friction compensation. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* Refer to the following section for details.<\/p>\n<p>\u25c6\tFeedforward <\/p>\n<p>If Pn140 is set to n.0 \u25af\u25af\u25af (Do not use model following control and speed\/torque feedforward together <\/p>\n<p>(default setting)) and tuning is performed with the mode selection set to 2 or 3, feedforward (Pn109), the speed feedforward <\/p>\n<p>input (V-REF), and the torque feedforward input (TREF) will be disabled. <\/p>\n<p>To use the speed feedforward input (V-REF), the torque feedforward input (T-REF), and model following control from the host <\/p>\n<p>controller in the system, set Pn140 to n.1 \u25af\u25af\u25af (Use model following control and speed\/torque feedforward together). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>n.0\u25af\u25af\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Do not use model following control and speed\/torque feedforward together. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.1\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Use model following control and speed\/torque feedforward together. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Refer to the following section for information on the torque feedforward input (T-REF) and the speed feedforward input (V-REF). <\/p>\n<p>When model following control is used with the feedforward function, it is used to make optimum feedforward settings in the <\/p>\n<p>ServoDriver. Therefore, model following control is not normally used together with either the speed feedforward input (V-REF) <\/p>\n<p>or torque feedforward input (T-REF) from the host controller. However, model following control can be used with the speed <\/p>\n<p>feedforward input (V-REF) or torque feedforward input (T-REF) if required. An unsuitable feedforward input may result in <\/p>\n<p>overshooting.\u3002<\/p>\n<p>12.6.7Related Parameters <br \/>\tThe following parameters are automatically adjusted or used as reference when you execute autotuning without a host reference. <\/p>\n<p>Do not change the settings while autotuning without a host reference is being executed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn100<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn101 <\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn102 <\/p>\n<\/td>\n<td>\n<p>Position Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn103 <\/p>\n<\/td>\n<td>\n<p>Moment of Inertia Ratio <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn121 <\/p>\n<\/td>\n<td>\n<p>Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn123 <\/p>\n<p>Pn124<\/p>\n<p>Pn125<\/p>\n<\/td>\n<td>\n<p>Friction Compensation Coefficient <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Frequency Correction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn401 <\/p>\n<\/td>\n<td>\n<p>First Stage First Torque Reference Filter Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn408 <\/p>\n<\/td>\n<td>\n<p>Torque-Related Function Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn409 <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40A <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40C <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40D <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>Model Following Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn141 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn142 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn143 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Forward Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn144 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Reverse Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn145 <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency A<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn146 <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency B<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn147 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Speed Feedforward Compensation <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn160 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn161 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Frequency<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn163 <br \/>Pn531<\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Damping Gain<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Program Jogging Travel Distance <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn533 <\/p>\n<\/td>\n<td>\n<p>Program Jogging Movement Speed for Rotary Servomotor <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn585 <\/p>\n<\/td>\n<td>\n<p>Program Jogging Movement Speed for Linear Servomotor <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn534 <\/p>\n<\/td>\n<td>\n<p>Program Jogging Acceleration\/Deceleration Time <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn535 <\/p>\n<\/td>\n<td>\n<p>Program Jogging Waiting Time <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn536 <\/p>\n<\/td>\n<td>\n<p>Program Jogging Number of Movements <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-047.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-048.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-049.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-050.png\" \/><\/p>\n<h3>12.7 Autotuning with a Host Reference <\/h3>\n<p>This section describes autotuning with a host reference. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Autotuning with a host reference makes adjustments based on the set speed loop gain (Pn100). Therefore, precise adjustments cannot be made if there is vibration when adjustments are started. Make adjustments after lowering the speed loop gain (Pn100) until vibration is eliminated.\u3002<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.7.1 Outline <\/h4>\n<p>Autotuning with a host reference automatically makes optimum adjustments for operation <\/p>\n<p>references from the host controller.\u3002 <\/p>\n<p>The following items are adjusted automatically. <\/p>\n<p>\u2022 Gains (e.g., speed loop gain and position loop gain) <br \/>\u2022 Filters (torque reference filter and notch filters) <br \/>\u2022 Friction compensation <br \/>\u2022 Anti-resonance control<br \/>\u2022 Vibration suppression <\/p>\n<p>Refer to the following section for details on the parameters that are adjusted. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-051.png\" \/><\/p>\n<p> CAUTION<\/p>\n<p>Because autotuning with a host reference adjusts the SERVOPACK during automatic operation, vibration or overshooting may occur. To ensure safety, make sure that you can perform an emergency stop at any time.\u3002<\/p>\n<h4>12.7.2Restrictions <\/h4>\n<p>Systems for Which Adjustments Cannot Be Made Accurately <\/p>\n<p>Adjustments will not be made correctly for autotuning with a host reference in the following cases. <\/p>\n<p>Use custom tuning. <\/p>\n<p>\u2022 When the travel distance for the reference from the host controller is equal to or lower than the setting of the positioning completed width (Pn522) <br \/>\u2022 Rotary Servomotors: When the movement speed for the reference from the host controller is equal to or lower than the setting of the rotation detection level (Pn502) <br \/>\u2022 Linear Servomotors: When the movement speed for the reference from the host controller is equal to or lower than the setting of the zero speed level (Pn581) <br \/>\u2022 When the time required to stop is 10 ms or less <br \/>\u2022 When the rigidity of the machine is low and vibration occurs when positioning is performed <br \/>\u2022 When the position integration function is used <br \/>\u2022 When proportional control is used<br \/>\u2022 When mode switching is used <br \/>\u2022 When the positioning completed width (Pn522) is too narrow <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-052.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-053.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-054.png\" \/><\/p>\n<p>Preparations <\/p>\n<p>Always check the following before you execute autotuning with a host reference. <\/p>\n<p>\u2022 The servo must be in ready status. <\/p>\n<p>\u2022 There must be no overtravel.\u3002 <\/p>\n<p>\u2022 The servo must be OFF. <\/p>\n<p>\u2022 Position control must be selected if power is supplied to the motor (i.e., when the servo is ON). \u2022 The gain selection switch must be set to manual gain selection (Pn139 = n.\u25af\u25af\u25af0). <\/p>\n<p>\u2022 The first gains must be selected. <\/p>\n<p>\u2022 There must be no warnings. <\/p>\n<p>\u2022 The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0). <\/p>\n<p>\u2022 The parameters must not be write prohibited.<\/p>\n<h4>12.7.3Applicable Tools<\/h4>\n<p>The following table lists the tools that you can use to perform autotuning with a host reference. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<td>\n<p>You cannot perform autotuning without a host reference from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital Operator <\/p>\n<\/td>\n<td>\n<p>Fn202 <\/p>\n<\/td>\n<td>\n<p>Digital Operator Operating Manual<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d [Tuning] <\/p>\n<\/td>\n<td>\n<p>Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.7.4 Operating Procedure<\/h4>\n<p>Use the following procedure to perform autotuning with a host reference. <\/p>\n<p> CAUTION<\/p>\n<p>If you are using an MP3000-Series Controller for phase control, set the mode selection to 1. If 2 or 3 is selected for the mode, correct phase control may not be possible. <\/p>\n<p><strong>1. <\/strong>Confirm that the moment of inertia ratio (Pn103) is set correctly. <\/p>\n<p><strong>2. <\/strong>Select Tuning in the Menu Dialog Bot <\/p>\n<p>The Tuning Dialog Box will be displayed. <\/p>\n<p>Click the Cancel Button to cancel tuning. <\/p>\n<p><strong>3. <\/strong>Click the OK Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-055.jpg\" \/><\/p>\n<p><strong>4. <\/strong>Select the Position reference input Option in the Autotuning Area and then click the Autotuning Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-056.jpg\" \/><\/p>\n<p>Set the conditions in the Mode selection Box and the Mechanism selection Box, and then click the Next Button. <br \/>If you select the Start tuning using the default settings Check Box in the Tuning parameters Area, the tuning parameters will be returned to the default settings before tuning is started.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-057.jpg\" \/><\/p>\n<p><strong>5. <\/strong>Input the correct moment of inertia ratio and click the Next Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-058.jpg\" \/><\/p>\n<p><strong>6. <\/strong>First confirm safety around moving parts. Then turn ON the servo, enter a reference from the host controller <\/p>\n<p>, and click the Start tuning Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-059.jpg\" \/><\/p>\n<p>Tuning will be executed. <\/p>\n<p>Vibration that occurs during tuning will be detected automatically and suitable settings will be made for that vibration. When the settings have been completed, the indicators for the functions that were used will light at the lower left of the dialog box.\u3002 <\/p>\n<p><strong>7. <\/strong>When tuning has been completed, click the Finish Button. <\/p>\n<p>The results of tuning will be set in the parameters and you will return to the Tuning Dialog Box. <\/p>\n<p>This concludes the procedure to perform autotuning with a host reference.<\/p>\n<h4>12.7.5 Troubleshooting Problems in Autotuning with a Host Reference<\/h4>\n<p>The following tables give the causes of and corrections for problems that may occur in autotuning with a host reference. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Autotuning with a Host Reference Was Not Performed <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Corrective Action <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Main circuit power supply is OFF.<\/p>\n<\/td>\n<td>\n<p>Turn ON the main circuit power supply. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>An alarm or warning occurred. <\/p>\n<\/td>\n<td>\n<p>Remove the cause of the alarm or warning. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Overtraveling occurred. <\/p>\n<\/td>\n<td>\n<p>Remove the cause of overtraveling. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The second gains were selected with the gain selection. <\/p>\n<\/td>\n<td>\n<p>Disable automatic gain switching. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The HWBB was activated.<\/p>\n<\/td>\n<td>\n<p>Release the HWBB. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Troubleshooting Errors <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Error <\/p>\n<\/td>\n<td>\n<p>Possible Cause <\/p>\n<\/td>\n<td>\n<p>Corrective Action <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>The gain adjustments were not successfully completed.<\/p>\n<\/td>\n<td>\n<p>Machine vibration occurs or positioning completion is not stable <br \/>when the Servomotor stops. <\/p>\n<\/td>\n<td>\n<p>\u2022 Increase the setting of the positioning completed width \t(Pn522). <\/p>\n<p>\u2022 Change the mode from 2 to 3. <\/p>\n<p>\u2022 If machine vibration occurs, suppress the vibration with the anti-resonance control adjustment and the vibration suppression function. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Positioning was not <br \/>completed within <br \/>approximately 10 seconds after position adjustment was completed. <\/p>\n<\/td>\n<td>\n<p>The positioning completed width is too narrow or <br \/>proportional control is being used. <\/p>\n<\/td>\n<td>\n<p>\u2022 Increase the setting of the positioning completed width \t(Pn522). <\/p>\n<p>\u2022 Turn OFF the \/P-CON (Proportional Control) signal. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Adjustment Results Are Not Satisfactory for Position Control <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>You may be able to improve the adjustment results by changing the settings of the positioning completed width (Pn522) and the electronic gear ratio (Pn20E\/Pn210). <\/p>\n<p>If satisfactory results are still not possible, adjust the overshoot detection level (Pn561). That may improve the adjustment results. <\/p>\n<p>\t\u2022 Pn561 = 100% [ default setting ] <br \/>This will allow tuning with overshooting that is equivalent to the positioning completed width. <\/p>\n<p>\u2022 Pn561 = 0%<\/p>\n<p>This will allow tuning to be performed without overshooting within the positioning completed width, but the <\/p>\n<p>positioning completed width may be extended. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn561 <\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Overshoot Detection Level<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>W<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>hen Enab<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>e<\/p>\n<\/td>\n<td>\n<p>Pos<\/p>\n<\/td>\n<td>\n<p>ition<\/p>\n<\/td>\n<td>\n<p>s<\/p>\n<\/td>\n<td>\n<p>Torque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>d <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.7.6 Automatically Adjusted Function Settings<\/h4>\n<p>These function settings are the same as for autotuning without a host reference. Refer to the following section. <\/p>\n<h4>12.6.6 Automatically Adjusted Function Settings<\/h4>\n<h4>12.7.7 Related Parameters<\/h4>\n<p>The following parameters are automatically adjusted or used as reference when you execute autotuning with a host reference. <\/p>\n<p>Do not change the settings while autotuning with a host reference is being <br \/>executed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn100<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn101<\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn102 <br \/>Pn103 <br \/>Pn121<\/p>\n<\/td>\n<td>\n<p>Position Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Moment of Inertia Ratio<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn123 <br \/>Pn124 <br \/>Pn125<\/p>\n<\/td>\n<td>\n<p>Friction Compensation Coefficient <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Frequency Correction<\/p>\n<\/td>\n<td>\n<p>No<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn401 <\/p>\n<\/td>\n<td>\n<p>First Stage First Torque Reference Filter Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn408<\/p>\n<\/td>\n<td>\n<p>Torque-Related Function Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn409 <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40A <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40C <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40D <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn140<\/p>\n<\/td>\n<td>\n<p>Model Following Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn141<\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn142<\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn143<\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Forward Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn144<\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Reverse Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn145 <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency A<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn146 <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency B<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn147<\/p>\n<\/td>\n<td>\n<p>Model Following Control Speed Feedforward Compensation<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn160<\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn161 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Frequency<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn163 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Damping Gain<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-060.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-061.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-062.png\" \/><\/p>\n<p>12.8Custom Tuning <\/p>\n<p>This section describes custom tuning.<\/p>\n<h4>12.8.1 Outline<\/h4>\n<p>You can use custom tuning to manually adjust the servo during operation using a speed or position reference input from the host controller. You can use it to fine-tune adjustments that were made with autotuning. <\/p>\n<p>The following items are adjusted automatically. <\/p>\n<p>\u2022 Gains (e.g., speed loop gain and position loop gain)<br \/>\u2022 Filters (torque reference filter and notch filters)<br \/>\u2022 Friction compensation<br \/>\u2022 Anti-resonance control <\/p>\n<p>Refer to the following section for details on the parameters that are adjusted. <\/p>\n<p>There are two adjustment methods that you can use for custom tuning. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>\tTuning Mode 0 (Setting Servo Gains Giving Priority to Stability) or 1 (Setting Servo Gains Giving \tPriority to Good Response) <br \/>These modes allow you to set stable control conditions for multiple servo gains by manipulating only one tuning level. Automatic setting of notch filters and anti-resonance control is provided if vibration is detected. Manual anti-resonance control adjustment is also possible during custom tuning.\u3002 <\/p>\n<p>Tuning Mode 2 (Setting Servo Gains Giving Priority to Position Control Applications) or 3 (Setting Servo Gains Giving Priority to Preventing Overshooting in Position Control Applications) Two tuning levels are manipulated to reduce positioning time even further and set multiple servo gains. <\/p>\n<p>Model following control is used to reduce the positioning time. <\/p>\n<p>If vibration is detected, notch filters and anti-resonance control are automatically adjusted, and friction compensation is automatically set. Manual anti-resonance control adjustment and vibration suppression are also possible during custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> CAUTION<\/p>\n<p>Vibration or overshooting may occur during custom tuning. To ensure safety, make sure that you can perform an emergency stop at any time. <\/p>\n<h4>12.8.2 Preparations<\/h4>\n<p>Always check the following before you execute custom tuning. <\/p>\n<p>\u2022 The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0).<br \/>\u2022 If speed control is used, tuning mode 0 or 1 must be set.<br \/>\u2022 The parameters must not be write prohibited.<\/p>\n<h4>12.8.3Applicable Tools<\/h4>\n<p>The following table lists the tools that you can use to perform custom tuning. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td>\n<p>\u2212<\/p>\n<\/td>\n<td>\n<p>You cannot perform custom tuning from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital Operator <\/p>\n<\/td>\n<td>\n<p>Fn203<\/p>\n<\/td>\n<td>\n<p>Digital Operator Operating Manual <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d [Tuning] <\/p>\n<\/td>\n<td>\n<p>Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-063.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-064.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-065.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-066.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-067.png\" \/><\/p>\n<h4>12.8.4Operating Procedure<\/h4>\n<p> Use the following procedure to perform custom tuning. <\/p>\n<p> WARNING<\/p>\n<p>Before you execute custom tuning, check the <br \/>information provided in the ProTuner operating <br \/>manual. <\/p>\n<p>Observe the following precautions. <\/p>\n<p>Make sure that you can perform an emergency stop at any time. <\/p>\n<p>When custom tuning is started, several parameters will be overwritten with the recommended settings, which may greatly <\/p>\n<p>affect the response before and after execution. Make sure that you can perform an emergency stop at any time. <\/p>\n<p>Set the moment of inertia correctly before you execute custom tuning. If the setting greatly differs from the actual <\/p>\n<p>moment of inertia, vibration may occur. <\/p>\n<p>If you change the feedforward level, the new setting will not be used immediately. It will be used after positioning is completed.\u3002<\/p>\n<p> CAUTION<\/p>\n<p>If you are using an MP3000-series Controller for phase control, set the tuning mode to 0 or 1. If 2 or 3 is selected for the tuning mode, correct phase control may not be possible. <\/p>\n<p><strong>1. <\/strong>Confirm that the moment of inertia ratio (Pn103) is set correctly. <\/p>\n<p><strong>2. <\/strong>Select Tuning in the Menu Dialog Box. <\/p>\n<p>The Tuning Dialog Box will be displayed. <\/p>\n<p>Click the Cancel Button to cancel tuning. <\/p>\n<p><strong>3. <\/strong>Click the OK Button. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-068.jpg\" \/><\/p>\n<p><strong>4. <\/strong> Click the Advanced adjustment Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-069.jpg\" \/><\/p>\n<p><strong>5. <\/strong>Click the Custom tuning Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-070.jpg\" \/><\/p>\n<p><strong>6. <\/strong>Set the Tuning mode Box and Mechanism selection Box, and then click the Next Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-071.jpg\" \/><\/p>\n<p>NOTE: The tuning modes that you can select depend on the servo driver setting. <\/p>\n<p><strong>7. <\/strong> If the moment of inertia ratio is not set correctly, correct the setting and then click the Next Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-072.jpg\" \/><\/p>\n<p><strong>8. <\/strong>Turn ON the servo, enter a reference from the host controller, and then click the Start tuning Button. \uff1cTuning Mode 0 or 1\uff1e \t\uff1cTuning Mode 2 or 3\uff1e <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-073.jpg\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-074.jpg\" \/><\/p>\n<p><strong>9. <\/strong>Use the [ \u25b2 ] and [ \u25bc ] Buttons to change the tuning level. <\/p>\n<p>Click the Back Button during tuning to restore the setting to its original value. The tuning level will return to the value from before when custom tuning was started. <\/p>\n<p>\uff1cTuning Mode 0 or 1\uff1e \t\uff1cTuning Mode 2 or 3\uff1e <\/p>\n<p>Increase the tuning level until <br \/>overshooting occurs.\u3002 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-075.jpg\" \/><\/p>\n<p>Increase the feedforward level until overshooting occurs and then increase the feedback level until overshooting is <br \/>eliminated. Repeat these changes to make the adjustment.\u3002 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-076.jpg\" \/><\/p>\n<p>NOTE: The new feedforward level will not be used until the positioning completed signal is output. <\/p>\n<p><strong>10. <\/strong>You can set the functions to suppress vibration (notch filters, automatic anti-resonance control \tsetting, anti-resonance control adjustment, and autotuning with a host reference) as required. <strong>11. <\/strong>When tuning has been completed, click the OK Button. <\/p>\n<p>The values that were changed will be saved in the servo driver and you will return to the Tuning Dialog Box. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-077.jpg\" \/><\/p>\n<p>This concludes the procedure to set up custom tuning.<\/p>\n<p><strong>Vibration Suppression Functions <\/strong><\/p>\n<p>\u25c6\tNotch Filters and Automatic Anti-resonance Control Setting <\/p>\n<p>If the vibration frequency that occurs when you increase the servo gains is at 1,000 Hz or higher, notch filters are <\/p>\n<p>effective to suppress vibration. If the vibration is between 100 Hz and 1,000 Hz, anti-resonance control is effective. <\/p>\n<p>\u25c6\tAutomatic Setting <\/p>\n<p>To set vibration suppression automatically, use the parameters to enable notch filters and automatic anti-resonance control setting. <\/p>\n<p>The notch filter frequency (stage 1 or 2) or anti-resonance control frequency that is effective for the vibration that was detected <\/p>\n<p>during tuning will be automatically set.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-078.jpg\" \/><\/p>\n<p>Auto-setting Cancel Buttons <br \/>The automatically set notch filter frequencies or the anti-resonance control frequencies may not always suppress vibration. Click the Cancel Button to reset the notch filter frequencies or the anti-resonance control frequencies to the values from just before these frequencies were set automatically. When they are reset, vibration detection will start again. <\/p>\n<p>Vib Detect Button <br \/>While the notch filter or automatic anti-resonance control setting function is enabled, you can click the Vib Detect Button to manually detect vibration. When you click the Vib Detect Button, the servo driver will detect vibration at that time, and set the notch filter frequency (stage 1 or 2) or anti-resonance control frequency that is effective for the detected vibration. You can also perform manual vibration detection even when the servo driver does not detect vibration. <\/p>\n<p>Anti-res Ctrl Adj Button<\/p>\n<p>You can use the Anti-res Ctrl Adj Button to execute the anti-resonance control adjust ment if fine-tuning is required. Refer to the following section. <\/p>\n<p>Vib Suppress Button<\/p>\n<p>Click the Vib Suppress Button to suppress low and transient vibration (oscillation) of approximately 1 Hz to 100 Hz that occurs during positioning. Refer to the following section. <\/p>\n<p>\u25c6\tAutotuning with a Host Reference <\/p>\n<p>You can perform autotuning with a host reference. Refer to the following section for details. <\/p>\n<p>12.8.5Automatically Adjusted Function Settings <br \/>You cannot use vibration suppression functions at the same time. Other automatic function settings are the same as for autotuning without a host reference. Refer to the following section. <\/p>\n<h4>12.8.6Tuning Example for Tuning Mode 2 or 3<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-079.png\" \/><\/p>\n<h4>12.8.7 Related Parameters<\/h4>\n<p>The following parameters are automatically adjusted or used as <br \/>reference when you execute custom tuning. <\/p>\n<p>Do not change the settings while custom tuning is being <br \/>executed.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn100<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn101 <\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn102 <\/p>\n<p>Pn103<\/p>\n<p>Pn121<\/p>\n<\/td>\n<td>\n<p>Position Loop Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Moment of Inertia Ratio <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn123 <\/p>\n<p>Pn124<\/p>\n<p>Pn125<\/p>\n<\/td>\n<td>\n<p>Friction Compensation Coefficient <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Frequency Correction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn401 <\/p>\n<\/td>\n<td>\n<p>First Stage First Torque Reference Filter Time Constant <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn408 <\/p>\n<\/td>\n<td>\n<p>Torque-Related Function Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn409 <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40A <\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40C <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40D <\/p>\n<\/td>\n<td>\n<p>Second Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>Model Following Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn141 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn142 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain Correction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn143 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Forward Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn144 <br \/>Pn145<\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Reverse Direction <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Suppression 1 Frequency A<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn146 <\/p>\n<p>Pn147<\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency B<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model Following Control Speed Feedforward Compensation <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn160 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn161 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Frequency<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn163 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Damping Gain<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-080.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-081.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-082.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-083.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-084.png\" \/><\/p>\n<h3>12.9 Anti-Resonance Control Adjustment <\/h3>\n<p>This section describes anti-resonance control. <\/p>\n<h4>12.9.1 Outline<\/h4>\n<p>Anti-resonance control increases the effectiveness of vibration suppression after custom tuning. <\/p>\n<p>Anti-resonance control is effective for suppression of continuous vibration frequencies from 100 to 1,000 Hz that occur when the control gain is increased. Vibration can be eliminated by setting vibration frequencies through automatic detection or by manually setting them to adjust the damping gain. Input an operation reference and execute this anti-resonance control adjust ment when there is vibration. <\/p>\n<p>Anti-resonance control is automatically set by autotuning without a host reference or autotuning with a host reference. Use anti-resonance control adjustment only if fine-tuning is required or readjustment is required as a result of a failure to detect vibration. <\/p>\n<p>Perform custom tuning if required to increase the response after performing anti-resonance control adjustment. If the control gain is increased, e.g., when custom tuning is performed, vibration may occur again. If that occurs, perform anti-resonance control adjustment again to fine-tune the parameters. <\/p>\n<p> CAUTION<\/p>\n<p>Related parameters will be set automatically when anti-resonance control adjustment is executed. This may greatly affect the response before and after execution. Make sure that you can perform an emergency stop at any time. <\/p>\n<p>Before you execute anti-resonance control adjustment, set the correct moment of inertia ratio (Pn103). If the setting greatly differs from the actual moment of inertia ratio, normal control of the machine may not be possible, and vibration may occur. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022Anti-resonance control adjustment detects vibration frequencies between 100 Hz and 1,000 Hz. If the vibration frequency is not within this range, use custom tuning with tuning mode 2 selected to automatically set a notch filter or use vibration suppression. <\/p>\n<p>\u2022Vibration reduction can be made more effective by increasing the anti-resonance damping gain (Pn163), but the vibration may become larger if the damping gain is too high. Increase the damping gain by approximately 0% to 200% in 10% increments while checking the effect on vibration. If vibration reduction is still insufficient at a gain of 200%, cancel the setting, and lower the control gain by using a different method, such as custom tuning. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.9.2 Preparations<\/h4>\n<p>Always check the following before you execute anti-resonance control adjustment. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 <br \/>\u2022 <\/p>\n<p>\u2022 <\/p>\n<\/td>\n<td>\n<p>The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0). <br \/>The control method must not be set to torque control. <\/p>\n<p>The parameters must not be write prohibited.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.9.3 Applicable Tools<\/h4>\n<p>The following table lists the tools that you can use to perform anti-resonance control adjustment. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>You cannot execute anti-resonance control adjustment from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital Operator <\/p>\n<\/td>\n<td>\n<p>Fn204 <\/p>\n<\/td>\n<td>\n<p>Digital Operator Operating Manual <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d [Tuning] <\/p>\n<\/td>\n<td>\n<p>Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-085.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-086.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-087.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-088.png\" \/><\/p>\n<h4>12.9.4 Operating Procedure <\/h4>\n<p>To execute anti-resonance control adjustment, an operation reference is input, and the adjust ment is executed while vibration is occurring. <\/p>\n<p>\u25cf\tTo automatically detect the vibration frequency <\/p>\n<p>\u25cf\tTo manually set the vibration frequency<\/p>\n<p> Use the following procedure to perform anti-resonance control. <\/p>\n<p> CAUTION<\/p>\n<p><strong>Before you execute anti-resonance control <\/strong><br \/><strong>adjustment, check the information provided in the <\/strong><br \/><strong>Protuner operating manual. <\/strong><\/p>\n<p><strong>Observe the following precautions. <\/strong><\/p>\n<p>Make sure that you can perform an emergency stop at any time. Parameters will be set automatically when anti-resonance <\/p>\n<p>control adjustment is executed. This may greatly affect the response before and after execution. Make sure that you can <\/p>\n<p>perform an emergency stop (to turn OFF the power supply) at any time. <\/p>\n<p>Set the moment of inertia correctly before you execute anti-resonance control adjustment. If the setting greatly differs <\/p>\n<p>from the actual moment of inertia, effective vibration reduction may not be possible. <\/p>\n<p>If you have already performed anti-resonance control adjustment and then you change the frequency, the current anti-resonance control effect may be lost. Caution is particularly required when automatically detecting the vibration frequency.\u3002<\/p>\n<p>If effective vibration reduction is not achieved even after you execute anti-resonance control adjustment, cancel the function <\/p>\n<p>and lower the control gain by using a different method, such as custom tuning.Perform custom tuning separately if required to <\/p>\n<p>increase the response after performing anti-resonance control adjustment. <\/p>\n<p>If the servo gain is increased, e.g., when custom tuning is performed, vibration may occur again. <\/p>\n<p>If that occurs, perform anti-resonance control adjustment again to fine-tune the parameters. <\/p>\n<p><strong>1. <\/strong>Perform steps 1 to 8 of the procedure for custom tuning. Refer to the following section for details.\u3002 <\/p>\n<p><strong>2. <\/strong>Click the Anti-res Ctrl Adj Button. <\/p>\n<p> The rest of the procedure depends on whether you know the vibration frequency.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-089.jpg\" \/><\/p>\n<p><strong>3. <\/strong>If you do not know the vibration frequency, click the Auto Detect Button. If you know the vibration frequency, <\/p>\n<p>click the Manual Set Button. <\/p>\n<p>To Automatically Detect the Vibration Frequency <\/p>\n<p>The frequency will be set. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-090.jpg\" \/><\/p>\n<p><strong>4. <\/strong>Click the Start adjustment Button. <\/p>\n<p>To Manually Set the Vibration Frequency <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-091.jpg\" \/><\/p>\n<p><strong>5. <\/strong>Use the [ \u25b2 ]and [ \u25bc ] Buttons in the Adjustment Area to change the settings. <\/p>\n<p>Click the Reset Button during tuning to restore the setting to its original value. The tuning level will return to the value from before when custom tuning was started. <\/p>\n<p>To Automatically Detect the Vibration Frequency        To Manually Set the Vibration Frequency <br \/>Change the setting of the damping gain.              Change the settings of the frequency and damping gain. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-092.jpg\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-093.jpg\" \/><\/p>\n<p><strong>6. <\/strong>When the adjustment has been completed, click the OK Button. <\/p>\n<p> The values that were changed will be saved in the servo driver and you will return to the Tuning Dialog Box. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-094.jpg\" \/><\/p>\n<p>This concludes the procedure to set up anti-resonance control.<\/p>\n<h4>12.9.5 Related Parameters <\/h4>\n<p>The following parameters are automatically adjusted or used as reference when you execute anti-resonance control adjustment. Do not change the settings while anti-resonance control adjustment is being executed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn160<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-Resonance Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Pn161 <\/p>\n<p>Pn162 <br \/>Pn163 <br \/>Pn164<\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Frequency<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-Resonance Gain Correction<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-Resonance Damping Gain<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Anti-Resonance Filter Time Constant 1 Correction<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn165 <\/p>\n<\/td>\n<td>\n<p>Anti-Resonance Filter Time Constant 2 Correction<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-095.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-096.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-097.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-098.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-099.png\" \/><\/p>\n<p>12.10Vibration Suppression <\/p>\n<p>This section describes vibration suppression. <\/p>\n<h4>12.10.1 Outline<\/h4>\n<p>You can use vibration suppression to suppress transient vibration at a low frequency from 1 Hz to 100 Hz, which is generated mainly when the machine vibrates during positioning. This is effective for vibration frequencies for which notch filters and anti-resonance control adjustment are not effective. <\/p>\n<p>Vibration suppression is automatically set by autotuning without a host reference or autotuning with a host reference. Use vibration suppression only if fine-tuning is required or readjustment is required as a result of a failure to detect vibration. <\/p>\n<p>To execute vibration suppression, input an operation reference and execute the function when there is vibration. <\/p>\n<p>Perform custom tuning if required to increase the response after performing vibration suppression. <\/p>\n<p> CAUTION<\/p>\n<p>Related parameters will be set automatically when vibration suppression is executed. This may greatly affect the response before and after execution. Make sure that you can perform an emergency stop at any time. <\/p>\n<p>Before you execute vibration suppression, set the correct moment of inertia ratio (Pn103) with autotuning without a host reference or another method. If the setting greatly differs from the actual moment of inertia ratio, normal control of the machine may not be possible, and vibration may occur. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022Vibration suppression detects vibration frequencies between 1 Hz and 100 Hz. <\/p>\n<p>\u2022Frequency detection will not be performed if there is no vibration in the position deviation or if the vibration frequency is outside the range of detectable frequencies. If that is a problem, use a device such as a displacement meter or vibration sensor to measure the vibration frequency. <\/p>\n<p>\u2022If an automatically detected vibration frequency is not suppressed, the actual frequency and the detected frequency may be \tdifferent. Fine-tune the detected frequency if necessary. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Items That Influence Performance <br \/>If continuous vibration occurs while the Servomotor is stopping, vibration suppression cannot be used to suppress the vibration effectively. In this case, use anti-resonance control adjustment or custom tuning. <\/p>\n<p>Detection of Vibration Frequencies <br \/>Frequency detection may not be possible if vibration does not appear in the position deviation or the vibration that results from the position deviation is too small. You can adjust the detection sensitivity by changing the setting of the residual vibration detection width (Pn560), which is set as a percentage of the positioning completed width (Pn522). Perform the detection of vibration frequencies again after adjusting the setting of Pn560. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn560 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Residual Vibration Detection Width <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 3000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: As a guideline, change the setting 10% at a time. If the setting of this parameter is lowered, the detection sensitivity will be increased. <\/p>\n<p>Vibration may not be detected accurately if the setting is too small. <\/p>\n<p>NOTE:The vibration frequencies that are automatically detected may vary somewhat with each positioning operation. Perform positioning several times and make adjustments while checking the effect of vibration suppression. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-100.png\" \/><\/p>\n<h4>12.10.2 Preparations <br \/>Always check the following before you execute vibration suppression. <\/h4>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 <br \/>\u2022 <\/p>\n<p>\u2022 <\/p>\n<\/td>\n<td>\n<p>Position control must be used. <\/p>\n<p>The tuning-less function must be disabled (Pn170 = n.\u25af\u25af\u25af0). <\/p>\n<p>The parameters must not be write prohibited.\u201d <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.10.3 Applicable Tools <br \/>\tThe following table lists the tools that you can use to perform vibration suppression. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Tool <\/p>\n<\/td>\n<td>\n<p>Fn No.\/Function Name <\/p>\n<\/td>\n<td>\n<p>Operating Procedure Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Panel Operator <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>You cannot execute vibration suppression from the Panel Operator. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital Operator <\/p>\n<\/td>\n<td>\n<p>Fn205 <\/p>\n<\/td>\n<td>\n<p>Digital Operator Operating Manual <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Protuner <\/p>\n<\/td>\n<td>\n<p>[Tuning] \uff0d [Tuning] <\/p>\n<\/td>\n<td>\n<p>Operating Procedure <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.10.4 Operating Procedure <br \/>\tUse the following procedure to perform vibration suppression. <\/h4>\n<p><strong>1. <\/strong>Perform steps 1 to 8 of the procedure for custom tuning. Refer to the following section for details. <strong>2. <\/strong>Click the Vib Suppress Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-101.jpg\" \/><\/p>\n<p><strong>3. <\/strong>Click the Import Button or click [ \u25b2 ]and [ \u25bc ]Button to manually adjust the set frequency. <\/p>\n<p>When you click the Import Button, the residual vibration frequency in the Servomotor is read as the set frequency. (The frequency can be read only when the residual vibration frequency is between 1.0 and 100.0.) <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Frequency detection will not be performed if there is no vibration or if the vibration frequency is outside the range of detectable frequencies. If a vibration frequency is not detected, provide a means of measuring the vibration frequency. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-102.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-103.jpg\" \/><\/p>\n<p><strong>4. <\/strong>Click the Set Button. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>No settings related to vibration suppression are changed during operation. If the Servomotor does not stop within approximately 10 seconds after changing the setting, an update timeout will occur. The setting will be automatically returned to the previous value. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-104.jpg\" \/><\/p>\n<p>If the vibration is not eliminated, use the [ \u25b2 ]and [ \u25bc ] Buttons for the set frequency to fine-tune thevalue and click <\/p>\n<p>the Set Button again.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-105.jpg\" \/><\/p>\n<p>Click the Reset Button during adjustment to restore the setting to its original value. The status from before when <\/p>\n<p>adjustment was started will be restored. <\/p>\n<p><strong>5. <\/strong>When the vibration has been eliminated, click the Finish Button. <\/p>\n<p>The updated value will be saved in the servo driver. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-106.png\" \/><\/p>\n<p>This concludes the procedure to set up vibration suppression. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-107.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-108.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-109.png\" \/><\/p>\n<p>12.10.5 Setting Combined Functions <br \/>\tYou can also use the feedforward function when you execute vibration suppression. <\/p>\n<p>In the default settings, feedforward (Pn109), the speed feedforward input (V-REF), and the torque feedforward input (T-REF) are disabled. <\/p>\n<p>To use the speed feedforward input (V-REF), the torque feedforward input (T-REF), and model following control from the host controller in the system, set Pn140 to n.1 \u25af\u25af\u25af (Use model following control and speed\/torque feedforward together). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>n.0\u25af\u25af\u25af<br \/>[default setting ] <\/p>\n<\/td>\n<td>\n<p>Do not use model following control and speed\/torque feedforward together. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.1\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Use model following control and speed\/ torque feedforward together. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Refer to the following section for information on the torque feedforward input (T-REF) and the speed feedforward input (V-REF). <\/p>\n<p>\u2022<\/p>\n<h4>12.10.6 Related Parameters <\/h4>\n<p>The following parameters are automatically adjusted or used as reference when you execute vibration suppression. <\/p>\n<p> Do not change the settings while vibration suppression is being executed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn140<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model Following Control-Related Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn141 <\/p>\n<p>Pn142<\/p>\n<\/td>\n<td>\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model Following Control Correction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn143 <\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Forward Direction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn144 <\/p>\n<p>Pn145<\/p>\n<\/td>\n<td>\n<p>Model Following Control Bias in the Reverse Direction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Vibration Suppression 1 Frequency A<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn146 <\/p>\n<p>Pn147<\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 1 Frequency B<\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model Following Control Speed Feedforward Compensation<\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn14A <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 2 Frequency <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn14B <\/p>\n<\/td>\n<td>\n<p>Vibration Suppression 2 Correction <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution.\u3002 <\/p>\n<p>12.11Additional Adjustment Functions<\/p>\n<p>This section describes the functions that you can use to make adjustments after you perform autotuning without a host reference, autotuning with a host reference, and custom tuning. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>Applicable Control Methods <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gain Switching <\/p>\n<\/td>\n<td>\n<p>Position control, speed control, or torque control* <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Friction Compensation <\/p>\n<\/td>\n<td>\n<p>Position control or speed control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current Control Mode Selection <\/p>\n<\/td>\n<td>\n<p>Position control, speed control, or torque control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Current Gain Level Setting <\/p>\n<\/td>\n<td>\n<p>Position control or speed control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Speed Detection Method Selection <\/p>\n<\/td>\n<td>\n<p>Position control, speed control, or torque control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Proportional Control<\/p>\n<\/td>\n<td>\n<p>Position control or speed control <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* Automatic gain switching is enabled only for position control. <\/p>\n<h4>12.11.1 Gain Switching<\/h4>\n<p>Two gain switching functions are available, manual selection and automatic switching. The manual switching function uses an external input signal to select the gains, and the automatic. <\/p>\n<p>switching function changes the gains automatically. You can use gain switching to shorten the positioning time by increasing the gains during positioning and suppressing vibration by decreasing the gains while stopping. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn139 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Use manual gain switching. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af2<\/p>\n<\/td>\n<td>\n<p>Use automatic gain switching pattern 1. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: Pn139 = n.\u25af\u25af\u25af1 is a reserved setting. Do not use this setting. <\/p>\n<p>Gain Switching Combinations <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Selected Gains <\/p>\n<\/td>\n<td>\n<p>Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Position Loop Gain <\/p>\n<\/td>\n<td>\n<p>Torque Reference Filter <\/p>\n<\/td>\n<td>\n<p>Model <br \/>Following <br \/>Control Gain<\/p>\n<\/td>\n<td>\n<p>Model Following Control <br \/>Correction <\/p>\n<\/td>\n<td>\n<p>Friction <br \/>Compensation Gain <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gain <br \/>Settings 1<\/p>\n<\/td>\n<td>\n<p>Speed <br \/>Loop Gain (Pn100) <\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <br \/>(Pn101) <\/p>\n<\/td>\n<td>\n<p>Position Loop Gain (Pn102) <\/p>\n<\/td>\n<td>\n<p>First Stage First <br \/>Torque Reference Filter Time <br \/>Constant (Pn401)<\/p>\n<\/td>\n<td>\n<p>Model <br \/>Following Control <br \/>Gain* <br \/>(Pn141) <\/p>\n<\/td>\n<td>\n<p>Model <br \/>Following <br \/>Control <br \/>Correction* (Pn142) <\/p>\n<\/td>\n<td>\n<p>Friction <br \/>Compensa tion Gain <br \/>(Pn121) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gain <br \/>Settings 2<\/p>\n<\/td>\n<td>\n<p>Second Speed <br \/>Loop <br \/>Gain <br \/>(Pn104) <\/p>\n<\/td>\n<td>\n<p>Second Speed Loop Integral Time Constant (Pn105) <\/p>\n<\/td>\n<td>\n<p>Second Position Loop <br \/>Gain <br \/>(Pn106) <\/p>\n<\/td>\n<td>\n<p>First Stage <br \/>Second Torque Reference Filter Time Constant (Pn412) <\/p>\n<\/td>\n<td>\n<p>Second Model Following <br \/>Control Gain* (Pn148) <\/p>\n<\/td>\n<td>\n<p>Second Model Following <br \/>Control Gain <br \/>Correction* <br \/>(Pn149) <\/p>\n<\/td>\n<td>\n<p>Second <br \/>Friction <br \/>Compensat ion <br \/>Gain(Pn122) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* Gain switching for the model following control gain and the model following control gain correction is applicable only to manual gain switching.  To enable gain switching with these parameters, a gain switching input signal must be used and the following con ditions must be met. If the   conditions are not met, these parameters will not be changed even if the other param eters in the above table are changed. <\/p>\n<p>\u2022 There must be no reference. <\/p>\n<p>\u2022 The motor must be stopped. <\/p>\n<p>Manual Gain Switching <br \/>With manual gain switching, you use the \/G-SEL (Gain Selection) signal to change between gain settings 1 and gain settings 2.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Type <\/p>\n<\/td>\n<td>\n<p>Signal <\/p>\n<\/td>\n<td>\n<p>Connector Pin No. <\/p>\n<\/td>\n<td>\n<p>Setting<\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>\/G-SEL <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Must be allocated. <\/p>\n<\/td>\n<td>\n<p>OFF <\/p>\n<\/td>\n<td>\n<p>Changes the gain settings to gain settings 1. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ON <\/p>\n<\/td>\n<td>\n<p>Changes the gain settings to gain settings 2. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Automatic Gain Switching <br \/>Automatic gain switching is enabled only for position control. The switching conditions are specified by using the following settings.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Switching <\/p>\n<p>Condition <\/p>\n<\/td>\n<td>\n<p>Selected Gains <\/p>\n<\/td>\n<td>\n<p>Switching Waiting Time <\/p>\n<\/td>\n<td>\n<p>Switching Time <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn139 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>n.\u25af\u25af\u25af2<\/p>\n<\/td>\n<td>\n<p>Condition A satisfied <\/p>\n<\/td>\n<td>\n<p>Gain settings 1 to gain settings 2 <\/p>\n<\/td>\n<td>\n<p>Gain Switching Waiting Time 1 Pn135 <\/p>\n<\/td>\n<td>\n<p>Gain <br \/>Switching <br \/>Time 1 <br \/>Pn131 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Condition A not satisfied <\/p>\n<\/td>\n<td>\n<p>Gain settings 2 to gain settings 1 <\/p>\n<\/td>\n<td>\n<p>Gain Switching Waiting Time 2 Pn136<\/p>\n<\/td>\n<td>\n<p>Gain <br \/>Switching <br \/>Time 2 <br \/>Pn132 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Select one of the following settings for switching condition A. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p> Parameter<\/p>\n<\/td>\n<td>\n<p>Position Control Gain Switching Condition A<\/p>\n<\/td>\n<td>\n<p>For Control Methods Other Than Position Control (No Switching)<\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Pn139 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af0\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>\/COIN (Positioning <br \/>Completion) signal ON<\/p>\n<\/td>\n<td>\n<p>Gain settings 1 used. <\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Immediately<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>\/COIN (Positioning <br \/>Completion) signal OFF<\/p>\n<\/td>\n<td>\n<p>Gain settings 2 used. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af2\u25af<\/p>\n<\/td>\n<td>\n<p>\/NEAR (Near) signal ON<\/p>\n<\/td>\n<td>\n<p>Gain settings 1 used. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af3\u25af<\/p>\n<\/td>\n<td>\n<p>\/NEAR (Near) signal OFF<\/p>\n<\/td>\n<td>\n<p>Gain settings 2 used. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af4\u25af<\/p>\n<\/td>\n<td>\n<p>Position reference filter output is 0 and reference pulse input is OFF.<\/p>\n<\/td>\n<td>\n<p>Gain settings 1 used. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af5\u25af<\/p>\n<\/td>\n<td>\n<p>Position reference pulse input is ON.<\/p>\n<\/td>\n<td>\n<p>Gain settings 2 used. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Automatic Switching Pattern 1 (Pn139 = n.\u25af\u25af\u25af2)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-110.png\" \/><\/p>\n<p>\u25c6Relationship between the Waiting Times and Switching Times for Gain Switching In this example, an ON \/COIN (Positioning Completion) signal is set as condition A for automatic gain switching. The position loop gain is changed from the value in Pn102 (Position Loop Gain) to the value in Pn106 (Second Position Loop Gain). When the \/COIN signal turns ON, the switching operation begins after the waiting time (Pn135). The switching operation changes the position loop gain linearly from the gain set in Pn102 to the gain set in Pn106 over the switching time (Pn131). <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-111.png\" \/><\/p>\n<p>NOTE:You can use gain switching for either PI control or I-P control (Pn10B = n.\u25af\u25af0 \u25af or \u25af\u25af1 \u25af). <\/p>\n<p>Related Parameters <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn100<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1Hz <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn101 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 \uff5e 51200 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>2000 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Pn102<\/p>\n<p>Pn401<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Position Loop Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>First Stage First Torque Reference Filter Time Constant<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>W<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>hen Enab<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>led <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn141 <\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<td>\n<p>500 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn142<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Model Following Control Gain Correction <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>500 \uff5e 2000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>1000 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn121 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn104<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Second Speed Loop Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1Hz <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn105<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Second Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 \uff5e 51200 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>2000 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">\n<p>Pn106<\/p>\n<p>Pn412<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Second Position Loop Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>First Stage Second Torque Reference Filter Time Constant<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>W<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>hen Enab<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>led <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn148<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Second Model Following Control Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<td>\n<p>500 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn149<\/p>\n<\/td>\n<td colspan=\"6\">\n<p> Second Model Following Control Gain Correction <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>500 \uff5e 2000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>1000 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn122<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Second Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Parameters Related to Automatic Gain Switching <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn131 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Gain Switching Time 1<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn132<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Gain Switching Time 2 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn135<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Gain Switching Waiting Time 1<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn136<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Gain Switching Waiting Time 2 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Related Monitoring <br \/>\u2022 Protuner <\/p>\n<p>You can monitor gain switching with the status monitor or with tracing. <\/p>\n<p>\u2022 Analog Monitors <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Analog Monitor <\/p>\n<\/td>\n<td>\n<p>Monitor Name <\/p>\n<\/td>\n<td>\n<p>Output Value <\/p>\n<\/td>\n<td>\n<p>Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn006 <br \/>Pn007 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>n.\u25af\u25af0B<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Active Gain Monitor <\/p>\n<\/td>\n<td>\n<p>1V <\/p>\n<\/td>\n<td>\n<p>Gain settings 1 are enabled. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2V <\/p>\n<\/td>\n<td>\n<p>Gain settings 2 are enabled. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.11.2 Friction Compensation <br \/>\tFriction compensation is used to compensate for viscous friction fluctuations and regular load fluctuations. <\/p>\n<p>You can automatically adjust friction compensation with autotuning without a host reference, autotuning with a host <\/p>\n<p>reference, or custom tuning, or you can manually adjust it with the following procedure.\u3002 <\/p>\n<p>Required Parameter Settings <\/p>\n<p>The following parameter settings are required to use friction compensation. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn408 <\/p>\n<\/td>\n<td>\n<p>n.0\u25af\u25af\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Disable friction compensation. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.1\u25af\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Enable friction compensation. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn121 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn122<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Second Friction Compensation Gain <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn123<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Friction Compensation Coefficient <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn124<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Friction Compensation Frequency Correction <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-10000 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>0.1Hz <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn125<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Friction Compensation Gain Correction <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-112.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-113.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-114.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-115.png\" \/><\/p>\n<p>Operating Procedure for Friction Compensation <\/p>\n<p> CAUTION<\/p>\n<p>Before you execute friction compensation, set the moment of inertia ratio (Pn103) as accurately as possible. If the setting greatly differs from the actual moment of inertia, vibration may occur. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Step <\/p>\n<\/td>\n<td>\n<p>Operation <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Set the following parameters related to friction compensation to their default settings. <\/p>\n<p>Friction compensation gain (Pn121): 100 <br \/>Second friction compensation gain (Pn122): 100 <br \/>Friction compensation coefficient (Pn123): 0 <br \/>Friction compensation frequency correction (Pn124): 0 <br \/>Friction compensation gain correction (Pn125): 100 <br \/>NOTE:Always use the default settings for the friction compensation frequency correction (Pn124) and friction \t\tcompensation gain correction (Pn125). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Gradually increase the friction compensation coefficient (Pn123) to check the effect of friction compensation. NOTE:Usually, set the friction compensation coefficient (Pn123) to 95% or less. If the effect is insufficient, \tincrease  the friction compensation gain (Pn121) by 10% increments until vibration stops. <\/p>\n<p>Effect of Adjusted Parameters <br \/>Pn121: Friction Compensation Gain and Pn122: Second Friction Compensation Gain These parameters set the response to external disturbances. The higher the setting is, the better the response will be. If the machine has a resonance frequency, however, vibration may occur if the setting is too high. <\/p>\n<p>Pn123: Friction Compensation Coefficient This parameter sets the effect of friction compensation. The higher the setting is, the more effective friction compensation will be. If the setting is too high, however, vibration will occur more easily. Usually, set the value to 95% or less. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>Effect of Adjustments <br \/>The following graphs show the response with and without adjustment. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-116.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.11.3 Current Gain Level Setting <\/h4>\n<p>You can set the current gain level to reduce noise by adjusting the parameter for current control inside the servo driver according to the speed loop gain (Pn100). The noise level can be reduced by decreasing the current gain level (Pn13D) from its default setting of 2,000% (disabled). However, if the setting is decreased, the level of noise will be lowered, but the response characteristic of the servo driver will also be reduced. Adjust the current gain level within the range that maintains the servo driver response characteristic. This function is always disabled during torque control (Pn000 = n.\u25af\u25af2 \u25af). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn13D <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Current Gain Level <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>100 \uff5e 2000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>2000 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>If the current gain level is changed, the response characteristic of the speed loop will also change. Servo tuning must therefore be performed again.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-117.png\" \/><\/p>\n<h4>12.11.4 Speed Detection Method Selection <\/h4>\n<p>You can use the speed detection method selection to ensure smooth Servomotor speed changes during operation. To ensure smooth motor speed changes during operation, set Pn009 to n.\u25af1 \u25af\u25af (Use speed detection 2). <\/p>\n<p>With a Linear Servomotor, you can reduce the noise level of the running motor when the linear encoder scale pitch is large.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn009 <\/p>\n<\/td>\n<td>\n<p>n.\u25af0\u25af\u25af<br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Use speed detection 1. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Use speed detection 2. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>If the speed detection method is changed, the response characteristic of the speed loop will also change. Servo tuning must therefore be performed again. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.11.5 Speed Feedback Filter <br \/>You can set a first order lag filter for the speed feedback in the speed loop. This ensures smooth changes in the feedback speed to reduce vibration. If a large value is set, it will increase the delay and make response slower. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn308<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Speed Feedback Filter Time Constant <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <br \/>\uff080.00 \uff5e 655.35ms\uff09<\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>0<br \/>\uff080.00ms\uff09 <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>12.11.6  Proportional Control (P Control) <br \/>\tYou can input the \/P-CON (Proportional Control) signal from the host controller to select P control. <\/p>\n<p>The speed control section uses proportional-integral control (PI control) if the reference remains at zero during speed control. The integral effect may cause the Servomotor to move. To prevent that, you can change from PI control to P control. <\/p>\n<p>P control is set using Pn000 = n.\u25af\u25afX \u25af and the \/P-CON signal. <\/p>\n<p>However, if Pn000 is set to n.\u25af\u25afA \u25af (Switching between speed control with analog references and speed control with zero clamping), a position loop will be formed. Therefore, there is no need to use this function. <\/p>\n<p>P control is used while the \/P-CON signal is ON. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-118.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-119.png\" \/><\/p>\n<p>\/P-CON (Proportional Control) Signal <br \/>The \/P-CON signal is used to switch between P control and PI control. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Type <\/p>\n<\/td>\n<td>\n<p>Signal <\/p>\n<\/td>\n<td>\n<p>Connector Pin No. <\/p>\n<\/td>\n<td>\n<p>Setting <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Input <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>\/P-CON<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>CN1-41 <br \/>[default setting ] <\/p>\n<\/td>\n<td>\n<p>ON \uff08closed\uff09 <\/p>\n<\/td>\n<td>\n<p>Changes to P control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OFF \uff08open\uff09 <\/p>\n<\/td>\n<td>\n<p>Changes to PI control <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When Using the Default Input Signal Allocations <br \/>\tservo driver<\/p>\n<p>\t\tCN1 <br \/>\t\/P-CON \t\t41<br \/> Changing between P and PI control<\/p>\n<p>NOTE:This example uses the default input signal allocations. <\/p>\n<p>Control Methods and P Control Input Signals <br \/>Changing to P control is enabled when the control method is set to speed control or position control. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Control Method Selection <\/p>\n<\/td>\n<td>\n<p>Description <\/p>\n<\/td>\n<td>\n<p>Changing to <br \/>P Control <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p>Pn000 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af0\u25af<br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Speed control with analog references <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>You can change to <br \/>P control with the <br \/>default setting (CN141 = \/P-CON). <\/p>\n<p>You can also allocate the \/P-CON signal to another connector <br \/>pin.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>Position control with pulse train references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af2\u25af<\/p>\n<\/td>\n<td>\n<p>Torque control with analog references <\/p>\n<\/td>\n<td>\n<p>You cannot change to P control. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af3\u25af<\/p>\n<\/td>\n<td>\n<p>Internal set speed control with contact commands <\/p>\n<\/td>\n<td rowspan=\"9\">\n<p>You must allocate the \/P-CON signal to <br \/>CN1-40 to CN1-46. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af4\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between internal set speed control with contact commands and speed control with analog references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af5\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between internal set speed control with contact commands and position control with pulse train references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af6\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between internal set speed control with contact commands and torque control with analog references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af7\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between position control with pulse train references and speed control with analog references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af8\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between position control with pulse train references and torque control with analog references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af9\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between torque control with analog references and speed control with analog references <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25afA\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between speed control with analog references and speed control with zero clamping <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25afB\u25af<\/p>\n<\/td>\n<td>\n<p>Switching between position control with pulse train references and position control with reference pulse inhibition <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: Refer to the following section for information on changing the control method. <\/p>\n<h3>12.12 Manual Tuning <\/h3>\n<p>This section describes manual tuning. <\/p>\n<h4>12.12.1 Tuning the Servo Gains<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-120.jpg\" \/><\/p>\n<p>In order to manually tune the servo gains, you must understand the configuration and characteristic of the servo driver and adjust the servo gains individually. In most cases, if you greatly change any one parameter, you must adjust the other parameters again. To check the response characteristic, you must prepare a measuring instrument to monitor the output waveforms from the analog monitor. <\/p>\n<p>The Servo Driver has three feedback systems (the position loop, speed loop, and current loop), and the response characteristic must be increased more with the inner loops. If this relationship is not maintained, the response characteristic will suffer and vibration will occur more easily. <\/p>\n<p>A sufficient response characteristic is ensured for the current loop. There is never a need for it to be adjusted by the user. <\/p>\n<p>Outline <br \/>You can use manual tuning to set the servo gains in the servo driver to increase the response characteristic of the servo driver. For example, you can reduce the positioning time for position control. <\/p>\n<p>Use manual tuning in the following cases. <\/p>\n<p>\u2022 When tuning with autotuning without a host reference or autotuning with a host reference does not achieve the \u2022 desired results <br \/>\u2022 When you want to increase the servo gains higher than the gains that resulted from autotuning without a host \u2022 reference or autotuning with a host reference <br \/>\u2022 When you want to determine the servo gains and moment of inertia ratio yourself <\/p>\n<p>You start manual tuning either from the default parameter settings or from the gain settings that resulted from autotuning without a host reference or autotuning with a host reference. <\/p>\n<p>Applicable Tools <br \/>You can monitor the servo gains with the Protuner or with the analog monitor. <\/p>\n<p>Precautions <br \/>Vibration may occur while you are tuning the servo gains. We recommend that you enable vibration alarms (Pn310 = n.\u25af\u25af\u25af2) to detect vibration. Refer to the following section for information on vibration detection. <\/p>\n<p>Tuning Procedure Example (for Position Control or Speed Control)<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Step <\/p>\n<\/td>\n<td>\n<p>Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Adjust the first stage first torque reference filter time constant (Pn401) so that vibration does not occur. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Increase the Speed loop gain (Pn100) and reduce the speed loop integral time constant (Pn101) as far as possible within the range that does not cause machine vibration. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>Repeat steps 1 and 2 and return the settings about 10% to 20% from the values that you set. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>For position control, increase the position loop gain (Pn102) within the range that does not cause vibration. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: If you greatly change any one servo gain parameter, you must adjust the other parameters again. Do not increase the setting of just one parameter. As a guideline, adjust the settings of the servo gains by approximately 5% each. As a rule, change the servo parameters in the following order.\u3002 <\/p>\n<p>\u2022 To Increase the Response Speed <\/p>\n<p>1. Reduce the torque reference filter time constant. <\/p>\n<p>2. Increase the speed loop gain. <\/p>\n<p>3. Decrease the speed loop integral time constant. <\/p>\n<p>4. Increase the position loop gain. <\/p>\n<p>\u2022 To Reduce Response Speed and to Stop Vibration and Overshooting <\/p>\n<p>1. Reduce the position loop gain. <\/p>\n<p>2. Increase the speed loop integral time constant. <\/p>\n<p>3. Decrease the speed loop gain. <\/p>\n<p>4. Increase the torque filter time constant. <\/p>\n<p>Adjusted Servo Gains <\/p>\n<p>You can set the following gains to adjust the response characteristic of the Servo Driver. <\/p>\n<p>\u2022 Pn100\uff1aSpeed Loop Gain <br \/>\u2022 Pn101\uff1aSpeed Loop Integral Time Constant <br \/>\u2022 Pn102\uff1aPosition Loop Gain <\/p>\n<p>\u2022 Pn401\uff1aFirst Stage First Torque Reference Filter Time Constant <\/p>\n<p>\u25c6\tPosition Loop Gain<\/p>\n<p>The position loop gain determines the response characteristic of the position loop in the Servo Driver. If you can increase the setting of the position loop gain, the response characteristic will improve and the positioning time will be shortened. However, you normally cannot increase the position loop gain higher than the inherit vibration frequency of the machine system. Therefore, to increase the setting of the position loop gain, you must increase the rigidity of the machine to increase the inherit vibration frequency of the machine. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn102<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Loop Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE:For machines for which a high position loop gain (Pn102) cannot be set, overflow alarms can occur during high-speed operation. If that is the case, you can increase the setting of the following parameter to increase the level for alarm detection. <\/p>\n<p>Use the following condition as a guideline for determining the setting. <\/p>\n<p>Pn520 \u2267 Maximum feed speed [reference units\/s] \u00d7 2.0 <br \/>Pn102\u00f710\uff081\/s\uff09<\/p>\n<p>If you use a position reference filter, transient deviation will increase due to the filter time constant. When you <\/p>\n<p>make the setting, consider deviation accumulation that may result from the filter.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn520<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Deviation Overflow Alarm Level <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 1073741823<\/p>\n<\/td>\n<td>\n<p>1 reference unit<\/p>\n<\/td>\n<td>\n<p>5242880 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25c6\tSpeed Loop Gain <\/p>\n<p>This parameter determines the response characteristic of the speed loop. If the response characteristic of the speed loop is low, it becomes a delay factor for the position loop located outside of the speed loop. This will result in overshooting and vibration in the speed reference. <\/p>\n<p>Therefore, setting the speed loop gain as high as possible within the range that will not cause the machine system to vibrate will produce a stable servo system with a good response characteristic. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn100<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Speed Loop Gain<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>osition<\/p>\n<\/td>\n<td>\n<p>s<\/p>\n<\/td>\n<td>\n<p>Torque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1Hz <\/p>\n<\/td>\n<td>\n<p>400 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-121.png\" \/><\/p>\n<p>The default setting of Pn103 (Moment of Inertia Ratio) is 100. Before you tune the servo, calculate the moment of inertia ratio with the above formula and set Pn103 to the calculation result.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn103 <\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Moment of Inertia Ratio<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>osition<\/p>\n<\/td>\n<td>\n<p>s<\/p>\n<\/td>\n<td>\n<p>Torque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>To enable response to even small inputs, the speed loop has an integral element. The integral element becomes a delay factor in the servo system. If the time constant is set too high, overshooting will occur, positioning settling time will increase, and the response characteristic will suffer. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn101 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Speed Loop Integral Time Constant <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 \uff5e 51200 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>2000 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>Torque Reference Filter <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>As shown in the following diagram, the torque reference filter contains a first order lag filter and notch filters <\/p>\n<p>arranged in series, and each filter operates independently. <\/p>\n<p>The notch filters can be enabled and disabled with Pn408 = n.\u25afX\u25afX and Pn416 = n.\u25afXXX. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-122.png\" \/><\/p>\n<p><strong>Torque Reference Filter <\/strong><\/p>\n<p>If you suspect that machine vibration is being caused by the Servo Drive, try adjusting the torque reference filter time constant. This may stop the vibration. The lower the value, the better the control response characteristic will be, but there may be a limit depending on the machine conditions. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"6\">\n<p>Pn401<\/p>\n<p>Pn40F<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>First Stage First Torque Reference Filter Time Constant<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>osition<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Torque<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>sification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>100 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>osition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Second Stage Second Torque Reference Filter Frequency<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>100 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz <\/p>\n<\/td>\n<td>\n<p>5000* <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn410<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Second Stage Second Torque Reference Filter Q Value<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>P<\/p>\n<\/td>\n<td>\n<p>osition<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Torque<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"4\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>50 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>0.01 <\/p>\n<\/td>\n<td>\n<p>50 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>* The filter is disabled if you set the parameter to 5,000. <\/p>\n<p>Notch Filters <br \/>The notch filter can eliminate specific frequency elements generated by the vibration of sources such as resonance of the shaft of a ball screw. <\/p>\n<p>The notch filter puts a notch in the gain curve at the specific vibration frequency (called the notch frequency). The frequency components near the notch frequency can be reduced or removed with a notch filter. <\/p>\n<p>Notch filters are set with three parameters for the notch filter frequency, notch filter Q value, and notch filter depth. This section describes the notch filter Q value and notch filter depth. <\/p>\n<p>Notch filter Q Value <br \/>The setting of the notch filter Q value determines the width of the frequencies that are filtered for the notch filter frequency. The width of the notch changes with the notch filter Q value. The larger the notch filter Q value is, the steeper the notch is and the narrower the width of frequencies that are filtered is. <\/p>\n<p>The notch filter frequency characteristics for different notch filter Q values are shown below. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-123.png\" \/><\/p>\n<p>Notch Filter Depth <\/p>\n<p>The setting of the notch filter depth determines the depth of the frequencies that are filtered for the notch <br \/>filter frequency. The depth of the notch changes with the notch filter depth. The smaller the notch filter depth is, the deeper the notch is, increasing the effect of vibration suppression. However, if the value is too small, vibration can actually increase. <\/p>\n<p>The notch filter is disabled if the notch filter depth, d, is set to 1.0 (i.e., if Pn419 is set to 1,000). <\/p>\n<p>The notch filter frequency characteristics for different notch filter depths are shown below. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-124.png\" \/><\/p>\n<p>You can enable or disable the notch filter with Pn408 and Pn416. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting ]Disable first stage notch filter. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Pn408 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Enable first stage notch filter. <\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td rowspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af0\u25af\u25af<br \/>[default setting ]Disable second stage notch filter. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>n.\u25af1\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Enable second stage notch filter. <\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting ]Disable third stage notch filter. <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn41F <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Enable third stage notch filter. <\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td rowspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>n.\u25af\u25af0\u25af<br \/>[default setting ]Disable fourth stage notch filter. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>Enable fourth stage notch filter. <\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>n.\u25af0\u25af\u25af<br \/>[default setting ]Disable fifth stage notch filter. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>n.\u25af1\u25af\u25af<\/p>\n<\/td>\n<td>\n<p>Enable fifth stage notch filter. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Set the machine vibration frequencies in the notch filter parameters. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>First Stage Notch Filter Frequency<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn409<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz <\/p>\n<\/td>\n<td>\n<p>5000 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>First Stage Notch Filter Q Value<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40A<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.01 <\/p>\n<\/td>\n<td>\n<p>70 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>First Stage Notch Filter Depth<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40B<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>0 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.001 <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Second Stage Notch Filter Frequency<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40C<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz <\/p>\n<\/td>\n<td>\n<p>5000 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Second Stage Notch Filter Q Value<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40D<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.01 <\/p>\n<\/td>\n<td>\n<p>70 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Second Stage Notch Filter Depth<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn40E<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>0 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.001 <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Third Stage Notch Filter Frequency<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn417<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz <\/p>\n<\/td>\n<td>\n<p>5000 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Third Stage Notch Filter Q Value<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn418<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.01 <\/p>\n<\/td>\n<td>\n<p>70 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Third Stage Notch Filter Depth<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn419<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>0 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.001 <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Fourth Stage Notch Filter Frequency<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn41A<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz <\/p>\n<\/td>\n<td>\n<p>5000 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Fourth Stage Notch Filter Q Value<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn41B<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>50 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.01 <\/p>\n<\/td>\n<td>\n<p>70 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Fourth Stage Notch Filter Depth<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td>\n<p>PositionTorque<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn41C<\/p>\n<\/td>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>0 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.001 <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-125.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-126.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"9\">\n<p>Pn41D<\/p>\n<p>Pn41E<\/p>\n<p>Pn41F<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Fifth Stage Notch Filter Frequency<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed<br \/> Enabled<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Position<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Torque<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>ication <\/p>\n<\/td>\n<\/tr>\n<tr><\/tr>\n<tr>\n<td>\n<p>50 \uff5e 5000 <\/p>\n<\/td>\n<td>\n<p>1Hz<\/p>\n<\/td>\n<td>\n<p>5000<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Fifth Stage Notch Filter Q Value<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed<br \/> Enabled<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>50 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.01<\/p>\n<\/td>\n<td>\n<p>70<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Fifth Stage Notch Filter Depth<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed<br \/> Enabled<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 1000 <\/p>\n<\/td>\n<td>\n<p>0.001<\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022Do not set notch filter frequencies (Pn409, Pn40C, Pn417, Pn41A, and Pn41D) that are close to the speed loop\u2019s response frequency. Set a frequency that is at least four times the speed loop gain (Pn100). (However, Pn103 (Moment of Inertia Ratio) must be set correctly. If the setting is not correct, vibration may occur and the machine may be damaged. <\/p>\n<p>\u2022Change the notch filter frequencies (Pn409, Pn40C, Pn417, Pn41A, and Pn41D) only while the Servomotor is <\/p>\n<p>stopped. Vibration may occur if a notch filter frequency is changed during operation. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Guidelines for Manually Tuning Servo Gains <br \/>When you manually adjust the parameters, make sure that you completely understand the information in the product manual and use the following conditional expressions as guidelines. The appropriate values of the parameter settings are influenced by the machine specifications, so they cannot be determined universally. When you adjust the parameters, actually operate the machine and use the Protuner or analog monitor to monitor operating conditions. Even if the status is stable while the Servomotor is stopped, an unstable condition may occur when an operation reference is input. Therefore, input operation references and adjust the servo gains as you operate the Servomotor. <\/p>\n<p>Stable gain: Settings that provide a good balance between parameters. <\/p>\n<p>However, if the load moment of inertia is large and the machine system contains elements prone to vibration, you must sometimes use a setting that is somewhat higher to prevent the machine from vibrating.\u3002 <\/p>\n<p>Critical gain: Settings for which the parameters affect each other\u3002 <\/p>\n<p>Depending on the machine conditions, overshooting and vibration may occur and operation may not be stable. If the critical gain condition expressions are not met, operation will become more unstable, and there is a risk of abnormal motor shaft vibration and round-trip operation with a large amplitude. Always stay within the critical gain conditions. <\/p>\n<p>If you use the torque reference filter, second torque reference filter, and notch filters together, the interference between the filters and the speed loop gain will be superimposed. Allow leeway in the adjustments.\u3002 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25c6<\/p>\n<\/td>\n<td>\n<p>When Pn10B = n.\u25af\u25af0\u25af (PI Control) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>The following adjusted value guidelines require that the setting of Pn103 (Moment of Inertia Ratio) is correctly set for the actual machine. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Guidelines are given below for gain settings 1. <\/p>\n<p>The same guidelines apply to gain settings 2 (Pn104, Pn105, Pn106, and Pn412).\u3002 <\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and Position Loop Gain (Pn102 [\/s]) <\/p>\n<p>Stable gain: Pn102 [\/s] \u2264 2\u03c0 \u00d7 Pn100\/4 [Hz]<\/p>\n<p>Critical gain: Pn102 [\/s] &lt; 2\u03c0 \u00d7 Pn100 [Hz]<\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and Speed Loop Integral Time Constant (Pn101 [ms]) <\/p>\n<p> Stable gain: Pn101 [ms] \u2265 4,000\/(2\u03c0 \u00d7 Pn100 [Hz]) <\/p>\n<p> Critical gain: Pn101 [ms] &gt; 1,000\/(2\u03c0 \u00d7 Pn100 [Hz]) <\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and First Stage First Torque Reference Filter Time Constant (Pn401 [ms]) <\/p>\n<p>Stable gain: Pn401 [ms] \u2264 1,000\/(2\u03c0 \u00d7 Pn100 [Hz] \u00d7 4) <\/p>\n<p>Critical gain: Pn401 [ms] &lt; 1,000\/(2\u03c0 \u00d7 Pn100 [Hz] \u00d7 1) <\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and Second Stage Second Torque Reference Filter Frequency (Pn40F [Hz]) Critical gain: Pn40F [Hz] &gt; 4 \u00d7 Pn100 [Hz] <\/p>\n<p>NOTE: Set the Second Stage Second Torque Reference Filter Q Value (Pn410) to 0.70. <\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and First Stage Notch Filter Frequency (Pn409 [Hz]) (or Second Stage Notch \tFilter Frequency (Pn40C [Hz]))<\/p>\n<p>Critical gain: Pn409 [Hz] &gt; 4 \u00d7 Pn100 [Hz]<\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and Speed Feedback Filter Time Constant (Pn308 [ms]) Stable gain: Pn308 [ms] \u2264 1,000\/(2\u03c0 \u00d7 Pn100 [Hz] \u00d7 4) <br \/>Critical gain: Pn308 [ms] &lt; 1,000\/(2\u03c0 \u00d7 Pn100 [Hz] \u00d7 1) <\/p>\n<p>\u25c6\tWhen Pn10B = n.\u25af\u25af1\u25af (I-P Control) <\/p>\n<p>Guidelines are given below for gain settings 1. <\/p>\n<p>The same guidelines apply to gain settings 2 (Pn104, Pn105, Pn106, and Pn412). <\/p>\n<p>For I-P control, the relationships between the speed loop integral time constant, speed loop gain, and position loop gain are different from the relationships for PI control. The relationship between other servo gains is the same as for PI control.<\/p>\n<p>\u2022 Speed Loop Gain (Pn100 [Hz]) and Speed Loop Integral Time Constant (Pn101 [ms]) Stable gain: Pn100 [Hz] \u2265 320\/Pn101 [ms]<\/p>\n<p>\u2022 Position Loop Gain (Pn102 [\/s]) and Speed Loop Integral Time Constant (Pn101 [ms]) Stable gain: Pn102 [\/s] \u2264 320\/Pn101 [ms]<\/p>\n<p>NOTE: Selecting the Speed Loop Control Method (PI Control or I-P Control)Usually, I-P control is effective for high-speed positioning and high-speed, high-precision processing applications. With I-P control, you can use a lower position loop gain than for PI control to reduce the positioning time and reduce arc radius reduction. However, if you can use mode switching to change to proportional control to achieve the desired application, then using PI control would be the normal choice. <\/p>\n<p>\u25c6 Decimal Points in Parameter Settings <\/p>\n<p>For the SC3 servo drivers, decimal places are given for the settings of parameters on the Digital Operator, <\/p>\n<p>Panel Operator, and in the manual. For example with Pn100 (Speed Loop Gain), Pn100 = 40.0 is used to indicate <\/p>\n<p>a setting of 40.0 Hz. In the following adjusted value guidelines, the decimal places are also given. <\/p>\n<p>\u2022  Speed Loop Gain (Pn100 [Hz]) and Speed Loop Integral Time Constant (Pn101 [ms]) <br \/>Stable gain: Pn101 [ms] \u2265 4,000\/(2\u03c0 \u00d7 Pn100 [Hz]), therefore If Pn100 = 40.0 [Hz], then Pn101 = 4,000\/(2\u03c0 \u00d7 40.0) \u2248 15.92 [ms].\uff09 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-127.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-128.png\" \/><\/p>\n<p>Model Following Control <br \/>You can use model following control to improve response characteristic and shorten positioning time. You can <br \/>use model following control only with position control. Normally, the parameters that are used for model following control are automatically set along with the servo gains by executing autotuning or custom tuning. However, you <br \/>must adjust them manually in the following cases. <\/p>\n<p>\u2022 When the tuning results for autotuning or custom tuning are not acceptable <br \/>\u2022 When you want to increase the response characteristic higher than that achieved by the tuning results for autotuning or custom tuning <br \/>\u2022 When you want to determine the servo gains and model following control parameters yourself <\/p>\n<p>The block diagram for model following control is provided below. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-129.png\" \/><\/p>\n<p>ServoDriver <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-130.png\" \/><\/p>\n<p>\u25c6\t\tManual Tuning Procedure <br \/>Use the following tuning procedure for using model following control. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Step <\/p>\n<\/td>\n<td>\n<p>Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Friction compensation must also be used. Set the friction compensation parameters. Refer to the following section for the setting procedure. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Adjust the servo gains. Refer to the following section for an example procedure. <\/p>\n<p> NOTE: 1. Set the moment of inertia ratio (Pn103) as accurately as possible. <\/p>\n<p> 2. Refer to the guidelines for manually tuning the servo gains and set a stable gain for the position loop gain (Pn102). <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>Increase the model following control gain (Pn141) as much as possible within the range in which overshooting and vibration do not occur. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>If overshooting occurs or if the response is different for forward and reverse operation, fine-tune model following control with the following settings: model following control bias in the forward direction (Pn143), model following control bias in the reverse direction (Pn144), and model following control speed feedforward compensation (Pn147). <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25c6\tRelated Parameters <\/p>\n<p>Next we will describe the following parameters that are used for model following control. <\/p>\n<p>\u2022 Pn140 \uff08Model Following Control-Related Selections\uff09 <br \/>\u2022 Pn141 \uff08Model Following Control Gain\uff09 <br \/>\u2022 Pn143 \uff08Model Following Control Bias in the Forward Direction\uff09 \u2022 Pn144 \uff08Model Following Control Bias in the Reverse Direction\uff09 <\/p>\n<p>\u2022 Pn147 \uff08Model Following Control Speed Feedforward Compensation\uff09 <\/p>\n<p>Model Following Control-Related Selections <br \/>Set Pn140 = n.\u25af\u25af\u25afX to specify whether to use model following control. <\/p>\n<p>If you use model following control with vibration suppression, set Pn140 to n.\u25af\u25af1 \u25af or Pn140 = n.\u25af\u25af2 \u25af. When you also perform vibration suppression, adjust vibration suppression with custom tuning in advance. <\/p>\n<p>NOTE: If you use vibration suppression (Pn140 = n.\u25af\u25af1 \u25af or Pn140 = n.\u25af\u25af2 \u25af), always set Pn140 to n.\u25af\u25af\u25af1 (Use model \tfollowing control). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter<\/p>\n<\/td>\n<td>\n<p>Function <\/p>\n<\/td>\n<td>\n<p>When Enabled<\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Pn140 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Do not use model following control. <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Use model following control. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af0\u25af<br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Do not perform vibration suppression. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>Perform vibration suppression for a specific frequency. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af2\u25af<\/p>\n<\/td>\n<td>\n<p>Perform vibration suppression for two specific frequencies.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Model Following Control Gain <br \/>The model following control gain determines the response characteristic of the servo system. If you increase the setting of the model following control gain, the response characteristic will improve and the positioning time will be shortened. The response characteristic of the servo system is determined by this parameter, and not by Pn102 (Position Loop Gain). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn141 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Model Following Control Gain <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit<\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 20000 <\/p>\n<\/td>\n<td>\n<p>0.1\/s <\/p>\n<\/td>\n<td>\n<p>500 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: For machines for which a high model following control gain cannot be set, the size of the position deviation in model following control will be determined by the setting of the model following control gain. For a machine with low rigidity, in which a high model following control gain cannot be set, position deviation overflow alarms may occur during high-speed operation. If that is the case, you can increase the setting of the following parameter to increase the level for alarm detection. <\/p>\n<p>Use the following conditional expression for reference in determining the setting. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-131.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn520<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Deviation Overflow Alarm Level <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 \uff5e 1073741823<\/p>\n<\/td>\n<td>\n<p>1 reference unit<\/p>\n<\/td>\n<td>\n<p>5242880 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Model Following Control Bias in the Forward Direction and Model Following Control Bias in the <\/p>\n<p>Reverse Direction<\/p>\n<p>If the response is different for forward and reverse operation, use the following parameters for fine-tuning. <\/p>\n<p>If you decrease the settings, the response characteristic will be lowered but overshooting will be less likely to occur. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn143<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Model Following Control Bias in the Forward Direction <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>1000 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn144<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Model Following Control Bias in the Reverse Direction <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>1000 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Model Following Control Speed Feedforward Compensation<\/p>\n<p>If overshooting occurs even after you adjust the model following control gain, model following control bias in <\/p>\n<p>the forward direction, and model following control bias in the reverse direction, you may be able to improve <\/p>\n<p>performance by setting the following parameter. <\/p>\n<p>If you decrease the settings, the response characteristic will be lowered but overshooting will be less likely to occur. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn147<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Model Following Control Speed Feedforward Compensation <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>0.1% <\/p>\n<\/td>\n<td>\n<p>1000 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Model Following Control Type Selection <br \/>When you enable model following control, you can select the model following control type. Normally, set Pn14F to n.\u25af\u25af\u25af1 (Use model following control type 2) (default setting). If compatibility with previous models is required, set Pn14F to n.\u25af\u25af\u25af0 (Use model following control type 1). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn14F <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0<\/p>\n<\/td>\n<td>\n<p>Use model following control type 1. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Use model following control type 2. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.12.2 Compatible Adjustment Functions<\/h4>\n<p>The compatible adjustment functions are used together with manual tuning. You can use these functions to improve adjustment results. These functions allow you to use the same functions as for SC3-Series servo drivers <br \/>to adjustSC3-Series servo drivers.\u3002 <\/p>\n<p>Feedforward <\/p>\n<p>The feedforward function applies feedforward compensation to position control to shorten the positioning time. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-132.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn109 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Feedforward <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn10A <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Feedforward Filter Time Constant <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 6400 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE: If you set the feedforward value too high, the machine may vibrate. As a guideline, use a setting of 80% or less.\u3002 <\/p>\n<p>Torque Feedforward and Speed Feedforward <\/p>\n<p>You can use the torque feedforward and speed feedforward functions to help shorten the positioning time. The <\/p>\n<p>reference is created from the differential of the position reference at the host controller. <\/p>\n<p>Torque feedforward:This is effective for speed control or position control. It is sent from the host controller along with the speed reference. Connect the speed reference from the host controller to the V-REF (CN1-5 and CN1-6) signal and the torque feedforward reference from the host controller to the T-REF (CN1- 9 and CN1-10) signal. <\/p>\n<p>Speed feedforward: This is effective only for position control. It is sent to the servo driver from the host controller along with the position reference. Connect the position reference from the host controller to the PULS and SIGN (CN1-7,CN1 -8, CN1-11, and CN1-12) signals and the speed feedforward reference from the host controller to the V-REF (CN1-5 and CN1-6) signal.<\/p>\n<p>\u25c6\tExamples of Connections to Host Controllers <\/p>\n<p>When servo driver Performs Speed Control <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-133.png\" \/><\/p>\n<p>When servo driver Performs Position Contro <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-134.png\" \/><\/p>\n<p>\u25a0\tRelated Parameters <\/p>\n<p>Torque feedforward is allocated to T-REF (Pn002 = n.\u25af\u25af\u25afX) and it is set using the torque reference input gain <\/p>\n<p>(Pn400) and T-REF filter time constant (Pn415). <\/p>\n<p>The default setting of Pn400 is 30. Therefore, if the torque feedforward value is \u00b13 V, then the torque is limited <\/p>\n<p>to \u00b1100% of the rated torque. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Pn002 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Do not use T-REF. <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Use T-REF as an external torque limit input. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af2<\/p>\n<\/td>\n<td>\n<p>Use T-REF as a torque feedback input. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af3<\/p>\n<\/td>\n<td>\n<p>Use T-REF as an external torque limit input when \/P-CL or \/N-CL is active.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"6\">\n<p>Pn400<\/p>\n<p>Pn415<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Torque Reference Input Gain<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>Po<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>sition<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Torque<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>sification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 \uff5e 100 <\/p>\n<\/td>\n<td>\n<p>0.1 V\/rated torque<\/p>\n<\/td>\n<td>\n<p>30 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>sition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"2\">\n<p>T-REF Filter Time Constant<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>Po<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn426<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Torque feedforward average movement time <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 5100 <\/p>\n<\/td>\n<td>\n<p>0.1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Immediately <\/p>\n<\/td>\n<td>\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>NOTE:1.Overshooting will occur if you set the torque feedforward too high. Set the optimum value while monitoring the response. \t 2.You cannot use the torque feedforward function together with torque limiting with an analog voltage reference. <\/p>\n<p>\u25a0\tSpeed Feedforward <br \/>You set the speed feedforward function with the position control option (Pn207 = n.\u25af\u25afX \u25af) and the speed reference input gain (Pn300). <\/p>\n<p>The default setting of Pn300 is 600. Therefore, if the speed feedforward value is \u00b16 V, then it will indicate the rated speed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>Parameter <\/p>\n<\/td>\n<td>\n<p>Meaning <\/p>\n<\/td>\n<td>\n<p>When Enabled <\/p>\n<\/td>\n<td>\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Pn207 <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af0\u25af<br \/>[default setting ]<\/p>\n<\/td>\n<td>\n<p>Do not use V-REF. <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>After restart <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af1\u25af<\/p>\n<\/td>\n<td>\n<p>Use V-REF as a speed feedback input. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn300<\/p>\n<\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Speed Reference Input Gain<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td>\n<p>Whe<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"2\">\n<p>Speed <br \/>n Enable<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>d <\/p>\n<\/td>\n<td>\n<p>Po<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>sition<\/p>\n<p>Torque<\/p>\n<p>sification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>150 \uff5e 3000 <\/p>\n<\/td>\n<td>\n<p>0.01 V\/Rated motor speed<\/p>\n<\/td>\n<td>\n<p>600 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn307<\/p>\n<\/td>\n<td colspan=\"9\">\n<p>Speed Reference Filter Time Constant <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 65535 <\/p>\n<\/td>\n<td>\n<p>0.01ms <\/p>\n<\/td>\n<td>\n<p>40 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn30C<\/p>\n<\/td>\n<td colspan=\"9\">\n<p>Speed Feedforward Average Movement Time <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 5100 <\/p>\n<\/td>\n<td>\n<p>0.1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> NOTE: Overshooting will occur if you set the feedforward too high. Set the optimum value while monitoring the response. <\/p>\n<p>Mode Switching (Changing between Proportional and PI Control) <br \/>You can use mode switching to automatically change between proportional control and PI control. Overshooting caused by acceleration and deceleration can be suppressed and the settling time can be reduced by setting the switching condition and switching levels. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-135.png\" \/><\/p>\n<p>\u25c6\tRelated Parameters <\/p>\n<p>Select the switching condition for mode switching with Pn10B = n.\u25af\u25af\u25afX. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p> Parameter<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Mode Switching Selection <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Parameter That Sets the Level<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>When Enabled<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Rotary <\/p>\n<p>Servomotor<\/p>\n<\/td>\n<td>\n<p>Linear <\/p>\n<p>Servomotor<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>Pn10B <\/p>\n<\/td>\n<td>\n<p>n.\u25af\u25af\u25af0 <br \/>[default setting]<\/p>\n<\/td>\n<td>\n<p>Use the internal torque <br \/>reference as the condition. <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Pn10C <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Immediately <\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>Setup <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af1<\/p>\n<\/td>\n<td>\n<p>Use the speed reference as the condition. <\/p>\n<\/td>\n<td>\n<p>Pn10D <\/p>\n<\/td>\n<td>\n<p>Pn181 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af2<\/p>\n<\/td>\n<td>\n<p>Use the acceleration <br \/>reference as the condition. <\/p>\n<\/td>\n<td>\n<p>Pn10E <\/p>\n<\/td>\n<td>\n<p>Pn182 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af3<\/p>\n<\/td>\n<td>\n<p>Use the position deviation as the condition. <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Pn10F <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>n.\u25af\u25af\u25af4<\/p>\n<\/td>\n<td>\n<p>Do not use mode switching.<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u2212<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25a0<\/p>\n<\/td>\n<td>\n<p>Parameters That Set the Switching Levels<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022 Rotary Servomotors <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn10C<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Mode Switching Level for Torque Reference <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 800 <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>200 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn10D<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Mode Switching Level for Speed Reference <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>1min-1<\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn10E<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Mode Switching Level for Acceleration <\/p>\n<\/td>\n<td>\n<p>Speed<\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 30000 <\/p>\n<\/td>\n<td>\n<p>1min-1\/ s <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Pn10F<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>Mode Switching Level for Position Deviation <\/p>\n<\/td>\n<td>\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit <\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 10000 <\/p>\n<\/td>\n<td>\n<p>1 reference unit <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25a0<\/p>\n<\/td>\n<td>\n<p>Using the Internal Torque Reference as the Mode Switching Condition (Default Setting) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When the Internal torque reference equals or exceeds the torque set for the mode switching level for <\/p>\n<p>torque reference (Pn10C), the speed loop is changed to P control. The default setting for the torque <\/p>\n<p>reference level is 200%. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-136.png\" \/><\/p>\n<p>\t\u25a0\tUsing the Speed Reference as the Mode Switching Condition<br \/>\u2022 Rotary Servomotors <br \/>\tWhen the speed reference equals or exceeds the speed set for the mode switching level for a \tspeed reference (Pn10D), the speed loop is changed to P control. <\/p>\n<p>\t\u25a0\tUsing the Acceleration as the Mode Switching Condition<br \/>\u2022 Rotary Servomotors <br \/>\tWhen the speed reference equals or exceeds the acceleration rate set for the mode switching \tlevel for acceleration (Pn10E), the speed loop is changed to P control.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-137.png\" \/><\/p>\n<p>\u25c6 Using the Position Deviation as the Mode Switching Condition <\/p>\n<p>When the position deviation equals or exceeds the value set for the mode switching level for position <\/p>\n<p>deviation (Pn10F), the speed loop is changed to P control. This setting is enabled only for position control. <\/p>\n<p>Position Integral <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-138.png\" \/><\/p>\n<p>The position integral is the integral function of the position loop. It is used for the electronic cams and electronic shafts when using the servo driver with a Yaskawa MP3000-Series Machine Controller. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Pn11F <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Position Integral Time Constant <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Position<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Setting Range <\/p>\n<\/td>\n<td>\n<p>Setting Unit Position<\/p>\n<\/td>\n<td>\n<p>Default Setting <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>When Enabled <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Classification <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 \uff5e 50000 <\/p>\n<\/td>\n<td>\n<p>0.1ms <\/p>\n<\/td>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Immediately <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Tuning <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-139.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-140.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-141.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-142.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-143.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>12.13 Diagnostic Tools <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>12.13.1 Easy FFT<\/h4>\n<p>The machine is made to vibrate and a resonance frequency is detected from the generated vibration to set notch filters according to the detected resonance frequencies. This is used to eliminate high-frequency vibration and noise. <\/p>\n<p>During execution of Easy FFT, a frequency waveform reference is sent from the servo driver to the Servomotor to automatically cause the shaft to rotate multiple times within 1\/4th of a rotation, thus causing the machine to vibrate. Execute Easy FFT after the servo is turned OFF if operation of the servo driver results in highfrequency noise and vibration <\/p>\n<p> WARNING<\/p>\n<p>Never touch the Servomotor or machine during execution of Easy FFT. Doing so may result in injury. <\/p>\n<p> CAUTION<\/p>\n<p>Use Easy FFT when the servo gain is low, such as in the initial stage of servo tuning. If you execute Easy FFT <\/p>\n<p>after you increase the gain, the machine may vibrate depending on the machine characteristics or gain balance.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-144.png\" \/><\/p>\n<p>Easy FFT is built into the servo driver for compatibility with previous products. Normally use autotuning <\/p>\n<p>without a host reference for tuning. <\/p>\n<p>Preparations <\/p>\n<p>Always check the following before you execute Easy FFT. <\/p>\n<p>\u2022 The parameters must not be write prohibited.<\/p>\n<p>\u2022 The main circuit power supply must be ON.<\/p>\n<p>\u2022 There must be no alarms. <\/p>\n<p>\u2022 The servo must be OFF. <\/p>\n<p>\u2022 There must be no overtravel. <\/p>\n<p>\u2022 An external reference must not be input. <\/p>\n<p>Operating Procedure <\/p>\n<p>Use the following procedure <\/p>\n<p><strong>1. <\/strong>Click the ServoDrive Button in the workspace of the Main Window of the Protuner.<\/p>\n<p>Select Easy FFT in the Menu Dialog Box. <\/p>\n<p>The Easy FFT Dialog Box will be displayed. <\/p>\n<p>Click the Cancel Button to cancel Easy FFT. You will return to the main window <\/p>\n<p><strong>2. <\/strong>Click the Servo ON Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-145.jpg\" \/><\/p>\n<p><strong>3. <\/strong>Select the instruction (reference) amplitude and the rotation direction in the Measurement condition Area, <\/p>\n<p>and then click the Start Button. <\/p>\n<p>The Servomotor shaft will rotate and measurements will start.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-146.jpg\" \/><\/p>\n<p>When measurements have been completed, the measurement results will be displayed. <\/p>\n<p><strong>4. <\/strong>Check the results in the Measurement result Area and then click the Measurement complete Button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-147.jpg\" \/><\/p>\n<p><strong>5. <\/strong>Click the Result Writing Button if you want to set the measurement results in the parameters. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/sc3-sc3man-en-12\/sc3-sc3man-en-12-148.jpg\" \/><\/p>\n<p>This concludes the procedure to set up <br \/>Related Parameters <br \/>The following parameters are automatically adjusted or used as reference when you execute Easy FFT. Do not change the settings of these parameters during execution of Easy FFT. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Parameter <\/p>\n<p>Pn408<\/p>\n<\/td>\n<td>\n<p>Name <\/p>\n<\/td>\n<td>\n<p>Automatic Changes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Torque-Related Function Selections <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Pn409 <\/p>\n<p>Pn40A <br \/>Pn40C <br \/>Pn40D<\/p>\n<\/td>\n<td>\n<p>First Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>First Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Second Stage Notch Filter Frequency <\/p>\n<\/td>\n<td>\n<p>Yes <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Second Stage Notch Filter Q Value <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pn456 <\/p>\n<\/td>\n<td>\n<p>Sweep Torque Reference Amplitude <\/p>\n<\/td>\n<td>\n<p>No <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Yes: The parameter is automatically set. <\/p>\n<p>No: The parameter is not automatically set, but the setting is read during execution. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>12.14 Modbus <\/p>\n<\/td>\n<td><\/td>\n<td rowspan=\"3\">\n<p>Read\/W<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>Length <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>Unit <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Comment <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Address<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Name <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>rite <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0x0000-0x07FF <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Paramaters <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RW <\/p>\n<\/td>\n<td>\n<p>Reference <\/p>\n<\/td>\n<td>\n<p>Auto back up to ERROM and saved <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Manual <\/p>\n<\/td>\n<td>\n<p>when power off <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0x1000-0x17FF <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Paramaters <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RW <\/p>\n<\/td>\n<td>\n<p>Reference <\/p>\n<\/td>\n<td>\n<p>Not back up to ERROM and not saved <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Manual <\/p>\n<\/td>\n<td>\n<p>when power off <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xC060<\/p>\n<\/td>\n<td>\n<p>Motor SN <\/p>\n<\/td>\n<td><\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>16 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE000 <\/p>\n<\/td>\n<td>\n<p>Motor Speed <\/p>\n<\/td>\n<td>\n<p>rpm <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un000 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE001 <\/p>\n<\/td>\n<td>\n<p>Speed Reference <\/p>\n<\/td>\n<td>\n<p>rpm <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un001 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE002 <\/p>\n<\/td>\n<td>\n<p>Torque Reference <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un002 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE005 <\/p>\n<\/td>\n<td>\n<p>Rotational Angle 2 <\/p>\n<\/td>\n<td>\n<p>deg <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un004 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE006 <\/p>\n<\/td>\n<td>\n<p>Input Signal Monitor <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un005 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE007 <\/p>\n<\/td>\n<td>\n<p>Output Signal Monitor <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un006 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE008 <\/p>\n<\/td>\n<td>\n<p>Input Reference Pulse Speed <\/p>\n<\/td>\n<td>\n<p>rpm <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un007 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0xE009 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Position Deviation <\/p>\n<\/td>\n<td>\n<p>Reference <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Un008 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Units <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE00B <\/p>\n<\/td>\n<td>\n<p>Accumulated Load Ratio <\/p>\n<\/td>\n<td>\n<p>1% <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un009 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE00C<\/p>\n<\/td>\n<td>\n<p>Regenerative Load Ratio <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>1% <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un00A <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>0xE00D<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Dynamic Brake Resistor Power Consumption <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>16 <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Un00B <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1% <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0xE00E <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Input Reference Pulse Counter <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Un00C <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Units <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE010 <\/p>\n<\/td>\n<td>\n<p>Feedback Pulse Counter <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Pulse <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<td>\n<p>Un00D <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>0xE012 <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Fully-closed Loop Feedback Pulse Counter <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Un00E <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pulse <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0xE01B <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Feedback Pulse Counter <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Un013 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Units <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE040 <\/p>\n<\/td>\n<td>\n<p>Absolute Encoder Multiturn Data <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Turn <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un040 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>0xE041 <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Position within One Rotation of Absolute Encoder <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>Un041 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pulse <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Reference <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0xEC00<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Absolute Position <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Un070 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Units <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE110 <\/p>\n<\/td>\n<td>\n<p>Servo Inteneral Status <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit0 Main Circuit <\/p>\n<\/td>\n<td rowspan=\"8\"><\/td>\n<td colspan=\"3\">\n<p>bit16 Motor Power Status <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit1 Encoder (PGRDY) <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit17 Reserve <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit2 Motor Power (Request) <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit18 Overcurrent <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit3 Dynamic Brake (DB) <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit19 Origin Not Passed <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit4 Rotation (Movement) Direction <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit21 Polarity Detection <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit5 Mode Switch <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit22 Polarity Detection Completed <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit6 Speed Reference <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit23 Reserve <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>bit7 Torque Reference <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>bit26 Clear Signal (CLR) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>bit8 Position Reference <\/p>\n<p>bit9 Position Reference Direction <\/p>\n<p>bit10 Reserve <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>bit11 Return To The Zero Position Completed <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>bit12 AC Power ON <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>bit13 CHARGE OK <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td colspan=\"4\" rowspan=\"2\">\n<p>Bit6 NCL <br \/>Bit7 SENSOR ON <br \/>Bit8 CLR <br \/>Bit9 Reserve <br \/>Bit10 Reserve <br \/>Bit11 Reserve <br \/>Bit12 Reserve <br \/>Bit13 Reserve <br \/>Bit14 Gain Selection 0 <\/p>\n<p>Bit3 TGON <\/p>\n<p>Bit4 S-RDY <br \/>Bit5 CLT <br \/>Bit6 VLT <br \/>Bit7 BK <br \/>Bit8 WARN <\/p>\n<p>1:Alarm  3:POT NOT  4:POT  5:NOT  6:bb  7:run   8:RUN Polarity Detection  A:Fstp <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>0xE51C <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Servo Control Mode <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>0:Speed 1:Position 2:Torque <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>0xE130 <\/p>\n<\/td>\n<td>\n<p>Bit15 Gain Selection 2 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>32 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Servo Inteneral Output Status <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Bit0 ALARM <\/p>\n<p>Bit1 COIN <\/p>\n<p>Bit2 V-CMP <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p>Bit9 NEAR <\/p>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE140 <\/p>\n<\/td>\n<td>\n<p>DC-Link Voltage <\/p>\n<\/td>\n<td>\n<p>1V <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>Un140 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>0xE50A<\/p>\n<\/td>\n<td>\n<p>Current Alarm State <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE517 <\/p>\n<\/td>\n<td>\n<p>Servo Software Version <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0xE51B <\/p>\n<\/td>\n<td>\n<p>Servo Status <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RO <\/p>\n<\/td>\n<td>\n<p>16 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>bit14 Regenerative Transistor <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"8\">\n<p>0xE120 <\/p>\n<\/td>\n<td>\n<p>bit15 Regenerative Error Detection <\/p>\n<\/td>\n<td rowspan=\"8\">\n<p>&#8212; <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RO <\/p>\n<\/td>\n<td rowspan=\"8\">\n<p>32 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Servo Inteneral Inputs Status <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit0 S-ON <\/p>\n<\/td>\n<td>\n<p>Bit16 PDET <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit1 P\/PI Switch <\/p>\n<\/td>\n<td>\n<p>Bit17 FSTP <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit2 P-OT <\/p>\n<\/td>\n<td>\n<p>Bit18-Dec <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit3 N-OT <\/p>\n<\/td>\n<td>\n<p>Bit19 EXT0 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit4 ALM_RESET <\/p>\n<\/td>\n<td>\n<p>Bit20 EXT1 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit5 PCL <\/p>\n<\/td>\n<td>\n<p>Bit21 EXT2 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>0x2700 <\/p>\n<\/td>\n<td>\n<p>Communication input <\/p>\n<p>Supported by V20F and above <\/p>\n<\/td>\n<td>\n<p>&#8212; <\/p>\n<\/td>\n<td>\n<p>RW <\/p>\n<\/td>\n<td>\n<p>32 <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>bit0 PGM-START      bit1 HOME-START        bit2 PGM-STEP          bit3 PGM-SEL0 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>bit4 PGM-SEL1       bit5 PGM-SEL2          bit6 PGM-SEL3          bit7 Reserve <\/p>\n<p>bit8 Reserve           bit9 Reserve              bit10 Reserve             bit11 PDET <\/p>\n<p>bit12 SON           bit13 ALM_RESET        bit14 Dec              bit15 Reserve <\/p>\n<p>bit16 P-OTReserve      bit17 N-OTReserve         bit18 PCL              bit19 NCL <\/p>\n<p>bit20 CLR           bit21 PCON             bit22 ZCLAMP           bit23 INHIBIT <\/p>\n<p>bit24 PSEL          bit25 SPD              bit26 SPA              bit27 SPB <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>bit28 CSEL          bit29 GSEL             bit30 SEN              bit31 FstpReserve <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When using Modbud RTU to control the servo (in internal program table position control mode), Pn000 needs to be set to 00C0 (control mode setting C is position control running with internal program). <\/p>\n<p>Internal program operation related parameters: <br \/>Pn640: <br \/>Hex0 (PGM-START): 0~7 are controlled by CN1 IO input, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO control <br \/>Hex1 (PGM-STEP): 0~7 are controlled by CN1 IO input, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO control <br \/>Pn641: <br \/>Hex0 (Program step 0 \/ SEL0 signal): 0~7 are controlled by CN1 IO input, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO control <br \/>Hex1 (Program step 1 \/ SEL1 signal): 0~7 are controlled by CN1 IO input, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO <br \/>Hex2 (Program step 2 \/ SEL2 signal): 0~7 are controlled by CN1 IO input control, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO <br \/>Hex3 (Program step 2 \/ SEL3 signal): 0~7 are controlled by CN1 IO input, 8 is fixed as invalid, can be controlled by external communication, 9 is fixed as valid, ignore external communication and CN1 IO <br \/>Control bit 0x2700 Communication input description: <br \/>1. The entire register must be written once with a single 32-bit integer. <\/p>\n<p>2. Please fill in 0 for unused or reserved bits. <\/p>\n<p>Example: <br \/>Communication control servo SON sets Bit 12 to 1 (0=Servo off 1= Servo on) 0x2700=0000 0000 0000 0000 0000 0001 0000 0000 0000(0x1000) <br \/>Communication command <br \/>01 10 27 00 00 02 04 00 00 10 00 41 9E <\/p>\n<p>Set the position and speed of program step 0 <br \/>0x0800=1 (=0 absolute position =1 relative position) 0x0801-0x0802 Target position (command unit) 0x0801=C350 Set the target position low bit to 50000 pulses <br \/>0x0802=0000 Set the target position high bit to 0 <br \/>0x0803=01F4 Set the running speed to 300 rpm (speed unit 100 pulses\/s, 500*100*60\/10000=300 rpm) Communication command <br \/>01 10 08 00 00 04 08 00 01 C3 50 00 00 01 F4 68 DA <br \/>Communication selection execution program step 0 <br \/>Servo SON must be issued first <br \/>0x2700=0000 0000 0000 0000 0000 0001 0000 0000 0000(0x1000) <br \/>Communication command <\/p>\n<p>01 10 27 00 00 02 04 00 00 10 00 41 9E <br \/>Select execution of program step 0 bit0=1 bit2=1 bit3=1 <br \/>0x2700=0000 0000 0000 0000 0001 0000 0000 1101(0x0001000D) <br \/>Communication command <br \/>01 10 27 00 00 02 04 00 00 00 0D 8D 9B <br \/>After the program step is completed, if you need to execute other program steps or repeat the execution, you must set bit2=0 and only keep the SON state <br \/>0x2700=0x 0000 0000 0000 0000 0000 0001 0000 0000 0000(0x1000) <br \/>Communication command <br \/>01 10 27 00 00 02 04 00 00 10 00 41 9E <br \/>Repeat execution and issue again <br \/>Select execution program step 0 bit0=1 bit2=1 bit3=1 <br \/>0x2700=0000 0000 0000 0000 0001 0000 0000 1101(0x0001000D) <br \/>Communication command <br \/>01 10 27 00 00 02 04 00 00 00 0D 8D 9B <br \/>Select other steps, such as step 3 <br \/>bit0=1 bit2=1 bit3=1 bit4=1(bit3~ bit6 are combined into 1 word to indicate the step number) <br \/>0x2700=0000 0000 0000 0000 0001 0000 0001 1101(0x0001011D) <br \/>Communication command <br \/>01 10 27 00 00 02 04 00 00 00 1D 8C 57 <\/p>\n<p>(Note) The action mode of PGM-START(bit0) is that when the signal is written to 0, it will stop immediately. If it is written to 1 again, PGM-STEP(bit2) needs to be re-triggered (the writing action is from 0-&gt;1) <\/p>\n<p>Internally set speed switching input (SPD, SPA, SPB) signal operation related parameters: <br \/>Pn000: 3 <br \/>Pn301~Pn303: Set the operation speed <br \/>After the setting is completed, the communication can be written to bit25 (SPD), bit26 (SPA), bit27 (SPB) <\/p>\n","protected":false},"excerpt":{"rendered":"<p>12.1 Overview and Flow of Tuning Tuning is performed to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[55],"tags":[],"class_list":["post-3307","post","type-post","status-publish","format-standard","hentry","category-en-sc3-sc3man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3307"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3307\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3307"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3307"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}