{"id":3335,"date":"2026-11-17T18:42:24","date_gmt":"2026-11-17T10:42:24","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-zh-26\/"},"modified":"2026-11-17T18:42:24","modified_gmt":"2026-11-17T10:42:24","slug":"p5hmi-fvd-zh-26","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-zh-26\/","title":{"rendered":"\u7b2c26\u7ae0 Modbus\u9598\u9053\u4f3a\u670d\u5668"},"content":{"rendered":"<p>\u3010Modbus\u9598\u9053\u4f3a\u670d\u5668\u3011\u529f\u80fd\u662f\u6307\u5c07HMI\u7576\u6210\u9598\u9053\uff0c\u4e0a\u4f4d\u6a5fPC\u4f7f\u7528\u5716\u63a7\u8edf\u9ad4\u3001HMI\u6216\u5176\u4ed6\u7684Modbus\u8a2d\u5099\uff0c\u900f\u904eModbus(\u4e3b\u7ad9) TCP \u5354\u8b70\u6216\u8005\u4e32\u53e3Modbus(\u4e3b\u7ad9)\u901a\u8a0a\u5354\u8b70\u9023\u7d50\u5230HMI\uff0c\u4e26\u900f\u904eHMI\u5c0d\u4e0b\u4f4d\u7684PLC\u3001\u8b8a\u983b\u5668\u3001\u4f3a\u670d\u3001\u6eab\u5ea6\u63a7\u5236\u5668\u7b49\u8a2d\u5099\u7684\u9023\u7d50\uff0c\u4e0a\u4f4d\u6a5f\u53ef\u8f15\u9b06\u5c07\u4e0b\u4f4d\u6a5f\u7684\u6578\u64da\u8b80\u56de\u3002\u8a2d\u8a08\u8005\u53ea\u8981\u900f\u904e\u8868\u683c\u7684\u586b\u5beb\uff0c\u81ea\u8a02Modbus\u4f4d\u5740\u5c0d\u61c9\u8868\uff0c\u9054\u5230\u8cc7\u6599\u8490\u96c6\u7684\u76ee\u7684\u3002<\/p>\n<p>\u76ee\u524d\u652f\u63f4\u4e59\u592a\u7db2\u8defModbus TCP\u3001Modbus RTU\u548cModbus ASCII \u7b49\u4e09\u7a2e\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-001.jpg\" \/><\/p>\n<p>\u5716 499  Modbus\u9598\u9053\u4f3a\u670d\u5668\u61c9\u7528\u793a\u610f\u5716<\/p>\n<p>\u672c\u7ae0\u5c07\u8aaa\u660eModbus\u9598\u9053\u4f3a\u670d\u5668\u7684\u8a2d\u5b9a\u8207\u61c9\u7528\u3002<\/p>\n<h3>26.1 Modbus\u9598\u9053\u4f3a\u670d\u5668\u8a2d\u5b9a<\/h3>\n<p>\u7576\u9a45\u52d5\u7a0b\u5f0f\u9078\u64c7\u70baModbus Slave(ASCII)\u6216Modbus Slave(RTU)\u6642\uff0c\u5728\u3010\u901a\u8a0a\u4ecb\u9762\u8a2d\u5b9a\u3011\u4e2d\u6703\u591a\u4e00\u500b\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u7684\u8a2d\u5b9a\u9801\u9762\uff0c\u5982\u4e0b\u5716\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-002.jpg\" \/><\/p>\n<p>\u5716 500 \u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u7684\u8a2d\u5b9a\u9801\u9762<\/p>\n<p>\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u7684\u8a2d\u5b9a\u8868\u683c\u5982\u4e0b\u5716\u6240\u793a\uff0c\u5404\u8a2d\u5b9a\u9078\u9805\u610f\u7fa9\u5982\u4e0b\uff1a<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-003.jpg\" \/><\/p>\n<p>\u5716 501 \u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u8868\u683c\u7684\u8a2d\u5b9a\u9801\u9762<\/p>\n<p>\u8868 307 \u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u8868\u683c\u7684\u8a2d\u5b9a\u5c6c\u6027<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u5c6c\u6027<\/p>\n<\/td>\n<td>\n<p>\u63cf\u8ff0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010\u65b0\u589e\u3011<\/p>\n<p>\u589e\u52a0\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u4e2d\u7684\u5c0d\u61c9\u5217\u6578\u3002<\/p>\n<p>\u3010\u522a\u9664\u3011<\/p>\n<p>\u522a\u9664\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u4e2d\u76ee\u524d\u9ede\u9078\u7684\u5c0d\u61c9\u5217\u3002<\/p>\n<p>\u3010\u9810\u8a2d\u3011<\/p>\n<p>\u5c07\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u56de\u5fa9\u5230\u8edf\u9ad4\u9810\u8a2d\u7684\u5217\u6578\u548c\u689d\u4ef6\u3002<\/p>\n<p>\u3010\u6e05\u9664\u3011<\/p>\n<p>\u5c07\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u6240\u6709\u5217\u6578\u6e05\u9664\u3002<\/p>\n<p>\u3010Modbus\u985e\u578b\u3011<\/p>\n<p>\u76ee\u524d\u652f\u63f40x\u30011x\u30013x\u30014x\u7b49\u56db\u7a2e\u985e\u578b\u3002<\/p>\n<p>0x\u70ba\u4e00\u500b\u53ef\u8b80\u53ef\u5beb\u7684\u4f4d\u5143\u985e\u578b\u3002<\/p>\n<p>1x\u70ba\u4e00\u500b\u552f\u8b80\u7684\u4f4d\u5143\u985e\u578b\u3002<\/p>\n<p>3x\u70ba\u4e00\u500b\u552f\u8b80\u7684\u5b57\u7d44\u985e\u578b\u3002<\/p>\n<p>4x\u70ba\u4e00\u500b\u53ef\u8b80\u53ef\u5beb\u7684\u5b57\u7d44\u985e\u578b\u3002<\/p>\n<p>\u3010Modbus\u5730\u5740\u3011<\/p>\n<p>\u6307\u5b9aPLC\u6216\u5176\u4ed6\u8a2d\u5099\u50b3\u56deModbus\u7684\u76ee\u6a19\u4f4d\u5740\u3002<\/p>\n<p>\u3010PLC\u5730\u5740\u3011<\/p>\n<p>\u6307\u5b9aPLC\u6216\u5176\u4ed6\u8a2d\u5099\u7684\u4f86\u6e90\u4f4d\u5740\u3002<\/p>\n<p>\u3010\u9577\u5ea6\u3011<\/p>\n<p>\u8a2d\u5b9a\u50b3\u9001\u7684\u9577\u5ea6\u3002<\/p>\n<p>\u3010\u66f4\u65b0\u983b\u7387\u3011<\/p>\n<p>\u8a2d\u5b9a\u50b3\u9001\u7684\u66f4\u65b0\u983b\u7387\uff0c\u6709\u5feb\u3001\u6b63\u5e38\u3001\u6162\u4e09\u7a2e\u53ef\u4ee5\u9078\u64c7\u3002<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>26.2 Modbus\u9598\u9053\u4f3a\u670d\u5668\u61c9\u7528<\/h3>\n<p>\u4f8b\u5982HMI\u900f\u904eCOM1\u548cFBS PLC\u9023\u7dda\uff0c\u900f\u904eCOM3\u548c\u4e09\u83f1FX3U PLC\u9023\u7dda\uff0c\u5982\u4e0b\u5716\u8a2d\u5b9a\uff0c\u5982\u9700\u6c42\u5c07\u8cc7\u6599\u80fd\u900f\u904e\u4e59\u592a\u7db2\u8def\u4e0a\u50b3\u8490\u96c6\u5230PC\u7684\u5716\u63a7\u8edf\u9ad4(\u6216Mod Scan\u8edf\u9ad4)\u4e2d\uff0c\u53ef\u4f9d\u4e0b\u9762\u6b65\u9a5f\u8a2d\u5b9a\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-004.jpg\" \/><\/p>\n<p>\u5716 502  HMI COM1\u53caCOM3\u9023\u7dda\u9801\u9762<\/p>\n<p>\u4f8b\u5982\u6b32\u5c07FBS PLC\u66ab\u5b58\u5668\u4f4d\u5740R100\u7684\u6578\u64da\u53ca\u8f38\u51fa\u9edeY0\u7684\u72c0\u614b\uff0c\u900f\u904e\u4e59\u592a\u7db2\u8def\u4e0a\u50b3\u8490\u96c6\u5230PC\u7684Modbus\u4f4d\u5740 4&#215;1\u53ca0x1\u4e2d\uff0c\u4ee5\u53ca\u5c07\u4e09\u83f1FX3U PLC\u66ab\u5b58\u5668\u4f4d\u5740D200\u7684\u6578\u64da\u53ca\u8f38\u51fa\u9edeY1\u7684\u72c0\u614b\uff0c\u900f\u904e\u4e59\u592a\u7db2\u8def\u4e0a\u50b3\u8490\u96c6\u5230PC\u7684Modbus\u4f4d\u5740 4&#215;2\u53ca0x2\u4e2d\u3002<\/p>\n<p><strong>\u6b65\u9a5f1<\/strong> : \u65b0\u589eModbus Slave(TCP) \u9a45\u52d5\u7a0b\u5f0f\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-005.jpg\" \/><\/p>\n<p>\u5716 503 \u65b0\u589eModbus Slave(TCP) \u9a45\u52d5\u7a0b\u5f0f<\/p>\n<p><strong>\u6b65\u9a5f2<\/strong> : \u9ede\u9078\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u8a2d\u5b9a\u9801\u9762\u3002<\/p>\n<p><strong>\u6b65\u9a5f3<\/strong> : \u9ede\u9078\u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u8868\u683c\uff0c\u4e26\u4f9d\u9020\u9700\u6c42\u8a2d\u5b9a\u5982\u5716 504\u3002<\/p>\n<p>\u7b2c\u4e00\u5217\u662f\u5c07FBS PLC\u8f38\u51fa\u9edeY0\u7684\u72c0\u614b\u50b3\u9001\u5230Modbus 0x1\u4f4d\u5740\u4e2d\u3002<\/p>\n<p>\u7b2c\u4e8c\u5217\u662f\u5c07\u4e09\u83f1FX3U PLC\u8f38\u51fa\u9edeY1\u7684\u72c0\u614b\u50b3\u9001\u5230Modbus 0x2\u4f4d\u5740\u4e2d\u3002<\/p>\n<p>\u7b2c\u4e09\u5217\u662f\u5c07FBS PLC\u66ab\u5b58\u5668\u4f4d\u5740R100\u7684\u6578\u64da\u50b3\u9001\u5230Modbus 4&#215;1\u4f4d\u5740\u4e2d\u3002<\/p>\n<p>\u7b2c\u56db\u5217\u662f\u5c07\u4e09\u83f1FX3U PLC\u66ab\u5b58\u5668\u4f4d\u5740D200\u7684\u6578\u64da\u50b3\u9001\u5230Modbus 4&#215;2\u4f4d\u5740\u4e2d\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-006.jpg\" \/><\/p>\n<p>\u5716 504 \u3010\u5730\u5740\u5c0d\u61c9\u8868\u3011\u8868\u683c\u8a2d\u5b9a<\/p>\n<p>\u6ce8\u610f:\u7576SCADA\u8edf\u9ad4\u8b80\u53d6\u4e0d\u5728\u8868\u683c\u4e2d\u5b9a\u7fa9\u7684Modbus\u4f4d\u5740\u6642\uff0cHMI\u6703\u56de\u50b3MODBUS\u4f8b\u5916\u56de\u61c9\u7d66SCADA\u8edf\u9ad4\u3002<\/p>\n<p>\u6b65\u9a5f4 : \u5c07\u5c08\u6848\u4e0b\u8f09\u5230 HMI\uff0c\u4e26\u9023\u7d50PLC\u4ee5\u53ca\u4e09\u83f1 PLC\uff0c\u548c PC\u7684\u5716\u63a7\u8edf\u9ad4(\u6216modScan\u8edf\u9ad4)\u3002<\/p>\n<p>\u6b65\u9a5f5 : \u57f7\u884c\u6642PLC R100\u7684\u6578\u64da\u53caY0\u7684\u72c0\u614b\uff0c\u4ee5\u53ca\u4e09\u83f1 PLC D200\u7684\u6578\u64da\u53ca\u8f38\u51fa\u9edeY1\u7684\u72c0\u614b\u6539\u8b8a\u6642\uff0c\u4fbf\u53ef\u4ee5\u5728PC\u7684\u5716\u63a7\u8edf\u9ad4(\u6216modScan\u8edf\u9ad4)\u4e2dModbus\u4f4d\u5740 4&#215;1\u30014&#215;2\u30010x1\u30010x2\u5bdf\u770b\u5230\uff0c\u6216\u8005\u6539\u8b8aPC\u7684\u5716\u63a7\u8edf\u9ad4(\u6216modScan\u8edf\u9ad4)\u4e2dModbus\u4f4d\u5740 4&#215;1\u30014&#215;2\u30010x1\u30010x2\u6578\u503c\u6216\u72c0\u614b\u53ef\u4ee5\u5728PLC\u548c\u4e09\u83f1 PLC\u5bdf\u770b\u5230\uff0c\u5982\u5716 505\u3002<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-zh-26\/p5hmi-fvd-zh-26-007.jpg\" \/><\/p>\n<p>\u5716 505  Modbus\u9598\u9053\u4f3a\u670d\u5668\u57f7\u884c\u7d50\u679c<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3010Modbus\u9598\u9053\u4f3a\u670d\u5668\u3011\u529f\u80fd\u662f\u6307\u5c07HMI\u7576\u6210\u9598\u9053\uff0c\u4e0a\u4f4d\u6a5fPC\u4f7f\u7528\u5716\u63a7\u8edf\u9ad4\u3001HMI\u6216\u5176\u4ed6\u7684Modbus\u8a2d\u5099\uff0c\u900f [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[56],"tags":[],"class_list":["post-3335","post","type-post","status-publish","format-standard","hentry","category-zh-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3335"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3335\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}