{"id":3345,"date":"2026-11-17T18:42:36","date_gmt":"2026-11-17T10:42:36","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-03\/"},"modified":"2026-11-17T18:42:36","modified_gmt":"2026-11-17T10:42:36","slug":"p5hmi-fvd-en-03","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-03\/","title":{"rendered":"Chapter 3 System"},"content":{"rendered":"<p>Click on the setting option in\u3010System\u3011and the related setting window will be displayed at the work space of the window.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-001.jpg\" \/><\/p>\n<p>Figure 42 System<\/p>\n<h3>3.1 Project Information<\/h3>\n<h4>3.1.1 Project File<\/h4>\n<p>Information on the project files including the name of the project, creator, and the last save time.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\T19_project.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-002.jpg\" \/><\/p>\n<p>Figure 43 Project File<\/p>\n<h4>3.1.2 HMI Model<\/h4>\n<p>Detailed information on the HMI can be seen here, including the series, name, screen information and other information.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-003.png\" \/><\/p>\n<p>Figure 44 HMI Model<\/p>\n<h4>3.1.3 Memory<\/h4>\n<p>The information of the memory configuration, users can set the size of the register and the type of backup memory used in the project. (For more details , please refer to chapter23.1-Internal Address Register Range)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-004.png\" \/><\/p>\n<p>Figure 45 Memory<\/p>\n<p>\u3010SS_EXPORT_XNV_BACKUPis triggered\u3011<\/p>\n<p>When this System Tags is on, it will save XNV, XNVA and other Preservation\u00a0Memory Registers UPS memory as files.<\/p>\n<p>If user choose\u3010Manual\u3011, it will pop up a window to let users choose the project to open and check asks for the path and file name to be saved.<\/p>\n<p>If user choose\u3010Auto\u3011, It will follow the settings of\u3010Save To\u3011and\u3010File name prefix\u3011generate files at the destination.<\/p>\n<p>If you want to import the exported file into another HMI, you need to use\u3010SS_IMPORT_XNV_BACKUP\u3011in\u3010System Tags\u3011or\u3010Import XNV Backup\u3011in\u3010Function Switch\u3011. Human machine interface will restart after the import is successful.<\/p>\n<h4>3.1.4 Project Security<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-005.png\" \/><\/p>\n<p>Figure 46 Project Security<\/p>\n<p>Table 14 Project Security<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Project Protection\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Enable Project Password\u3011<\/p>\n<p>After checking, the next time you open this project, you need to enter a password to open it. You can set the password of the project in the\u3010Change\u3011at the back. If this item is set, after the project is uploaded from HMI and decompiled, a password is required to open the project.<\/p>\n<p>\u3010Deny Decompile\u3011<\/p>\n<p>When checked, decompilation will be prohibited for this project. After uploading from the HMI, if you want to decompile, there will be a prompt message that you are not allowed.<\/p>\n<p>\u3010Decompile Use Project Password\u3011<\/p>\n<p>This option needs to be checked\u3010Enter project password\u3011to select. After checking, when the project is to be decompiled, it will be required to enter the password of\u3010Project Protection\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Project Execution Protection\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When the project is executed, it will compare whether the password set here is the same as the password of the\u3010Customer ID\u3011in the\u3010System Settings\u3011of the HMI. The following are the rules for judging whether to enter the project.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p><strong>HMI without ID<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>HMI with ID<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Project without ID<\/strong><\/p>\n<\/td>\n<td>\n<p>The project is running normally<\/p>\n<\/td>\n<td>\n<p>The project is running normally<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Project with ID<\/strong><\/p>\n<\/td>\n<td>\n<p>Can&#8217;t enter project<\/p>\n<\/td>\n<td>\n<p><strong>Same password:<\/strong> normal operation<\/p>\n<p><strong>Different passwords:<\/strong> can&#8217;t enter project<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Enable Customer ID\u3011<\/p>\n<p>After checking, you can set the password of the customer ID code in\u3010Change\u3011at the back.<\/p>\n<p>For setting the customer identification code on the HMI, please refer to section 24.2.10.2-\u3010Security\u3011<\/p>\n<p>\u3010Security\u3011<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Project Upload and Download Protection\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Enable Upload Password\u3011<\/p>\n<p>After downloading to the HMI, you will need to enter the password the next time you want to upload it; if you make the project into a USB flash drive to update the file, and then update it to the HMI, you will need to enter the upload password when using the software to upload at this time.<\/p>\n<p>\u3010Deny Upload\u3011<\/p>\n<p>After enabling, the project will not be able to upload from the HMI to the computer. <\/p>\n<p>\u3010Enable Download Password\u3011<\/p>\n<p>If you choose to use the\u3010Download\u3011function in\u3010Tools (T)\u3011, you will need to enter the download password when you want to download to the HMI protected by the download password.<\/p>\n<p>\u203bIf you use\u3010Download Current Project\u3011in\u3010Project (P)\u3011, you will not be asked to enter the download password.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>3.2 Unit Setting<\/h3>\n<h4>3.2.1 Basic<\/h4>\n<p>The basic setting includes the Startup, Idle State, and Object.<\/p>\n<p>It is recommended to enable<strong>\u3010Screen Saver\u3011<\/strong>and<strong>\u3010Backlight Saver\u3011<\/strong>functions and set them within 60 minutes to avoid image afterimages caused by the HMI displaying the same screen for a long time.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-006.jpg\" \/><\/p>\n<p>Figure 47 Unit Setting-Basic<\/p>\n<p>Table 15 Unit Setting-Basic<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Startup\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The startup delay time can be set up to 255 seconds, and the project will not enter until the end of the countdown.<\/p>\n<p>\u3010Need Password to Log In\u3011<\/p>\n<p>Power on the HMI before enter the project, you need to enter a valid password in\u3010Security\u3011to log in.<\/p>\n<p>Notice to the following points when using this function: <\/p>\n<ul>\n<li>If you close\/cancel the login window, the login window will still pop up again<\/li>\n<li>If there is a\u3010Delay Time\u3011for booting up, the login window will pop up after the time counts down<\/li>\n<li>If\u3010USB Security Key\u3011is enabled, after the login window pops up, you can plug in the USB flash drive to log in directly to enter the project screen<\/li>\n<li>After entering the password to log in, entering the project will also be logged in the status of the level<\/li>\n<li>If the project start screen has set a\u3010Security Level\u3011, you need to enter a password that is greater than or equal to the screen security level to enter the project<\/li>\n<li>If the screen saver is set, it will enter the screen saver after the waiting time, but the recovery setting of the screen saver becomes invalid<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Idle State\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>In the idle state, the screen saver and backlight saver can be set. When the operation is idle for a period of time, the screen saver can be switched to the preset window or the backlight saver can be turned on to achieve the power saving effect.<\/p>\n<p>\u3010Screen Saver\u3011<\/p>\n<p>In addition to switching to the user-defined basic screen, the screen saver also provides a default screen saver screen, which has two modes of displaying\u3010Time\u3011and\u3010Custom Text\u3011, which is convenient for users to use without configuring any screen .<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>\u3010Time\u3011<\/strong>mode<\/p>\n<\/td>\n<td>\n<p><strong>\u3010<\/strong>Custom Text<strong>\u3011<\/strong>mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-007.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-008.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Font\u3011<\/p>\n<p>Set the screen saver time or customize text font.<\/p>\n<p>\u3010Size\u3011<\/p>\n<p>Set the screen saver time or customize text size.<\/p>\n<p>\u3010Text\u3011<\/p>\n<p>Set the screen saver time or customize text.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Resume Settings\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Settings for actions the HMI takes when exiting the Idle State are set here. <\/p>\n<p>\u3010Change to Screen\u3011<\/p>\n<p>Allows the user to control which screen the HMI is at upon exiting from the screen saver.\u3010None\u3011means stay in the screen which was before entering the screen saver. For example, if choose\u3010None\u3011, if it is idle for more than the waiting time set by the screen saver, then enter the screen saver. When the screen saver is restored, the HMI will display on screen 5.<\/p>\n<p>\u3010Auto Log-out\u3011<\/p>\n<p>When the\u3010Security\u3011function is used and the login level is greater than 0 before entering the screen saver, the HMI will log out the password to level 0 when this option is checked and the screen saver is restored.<\/p>\n<p>\u3010Show Log-in Dialog\u3011<\/p>\n<p>When the\u3010Security\u3011function is used and the login level is greater than 0 before entering the screen saver, the HMI will automatically display the login dialog when this option is checked and the screen saver is restored. This option is valid only if the\u3010Auto Log-out\u3011option is checked.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Backlight Saver\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check whether to enable the backlight energy saving function.<\/p>\n<p>\u3010Waiting Time\u3011<\/p>\n<p>Set the waiting time of no operation to turn off the HMI backlight.<\/p>\n<p>\u3010Turn on backlight when base screen changed\u3011<\/p>\n<p>If checked, when the screen enters the backlight energy saving mode, if the HMI has a page change action (such as using an alarm or change screen by register), the screen will be forced to light up.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Object\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Overlapped switches can be activated in sequence by one touch\u3011If there are multiple buttons overlapped in the same position, when this position is touched, the overlapped buttons will be triggered at the same time. If 4 buttons (M0, M1, M2, M3) were overlapped, then they will be triggered.<\/p>\n<p>\u3010Animation Object Position Update Rate\u3011<\/p>\n<p>Update rate for the object.<\/p>\n<p>\u3010Disabled Sign Style\u3011<\/p>\n<p>There are 4 styles to satisfy the different requirements and the setting will be applied in the whole project.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-009.jpg\" \/><\/p>\n<p>\u3010Window Title Bar Height\u3011<\/p>\n<p>After enabling this function, you can adjust the height of the title bar above the pop-up window, pop-up keyboard, etc. It should be noted that it will not have an effect when the model is PC and when using simulation.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-010.png\" \/><\/p>\n<p>\u3010Scroll Bar Width\u3011<\/p>\n<p>This is to set the scroll width of all objects with sliders in the project, such as\u3010Alarm Display\u3011. If the scroll width of this component is set by device, the settings here will be read.<\/p>\n<p>\u3010Disable screen image optimize(Screen image and text will be sharpening\u3011<\/p>\n<p>Will optimize the image and words, but the use of memory will increase.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Screenshot\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Current Active Screen\u3011Captures the topmost window, which may be a popup window or a keyboard.<\/p>\n<p>\u3010Base Screen Only\u3011Captures only the bottom-most base screen of the current display and does not include any pop-up windows above it.<\/p>\n<p>\u3010Full Screen\u3011Captures everything currently displayed on the screen, exactly as seen.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.2 PLC Sync<\/h4>\n<p>Writing to or reading time from PLC.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-011.png\" \/><\/p>\n<p>Figure 48 Unit Setting-PLC Sync<\/p>\n<p>Table 16 Unit Setting-PLC Sync<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Clock\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>HMI has built-in RTC clock. It can be synchronized with PLC RTC by this function.<\/p>\n<p>\u3010Write Time\/Date to PLC\u3011<\/p>\n<p>\u3010Write Address\u3011Write the value in Time Register of HMI to the Write Address of PLC.<\/p>\n<p>\u3010Write Mode\u3011Set the execution conditions<\/p>\n<p>\t\u3010Bit Trigger\u3011when the bit set on, it will sync PLC. Please note that this bit will not be automatically reset.<\/p>\n<p>\t\u3010Time Interval\u3011Set how long it takes to execute, the range is 1~255 minutes.<\/p>\n<p>\u3010Write Format\u3011Set the format for writing data.<\/p>\n<p>\u3010Synchronize HMI with PLC\u3011<\/p>\n<p>\u3010Read Address\u3011read the value in set address and write to the Time Register of HMI<\/p>\n<p>\u3010Read Mode\u3011Set the execution conditions<\/p>\n<p>\t\u3010Bit Trigger\u3011when the bit set on, it will sync PLC. Please note that this bit will not be automatically reset.<\/p>\n<p>\t\u3010Time Interval\u3011Set how long it takes to execute, the range is 1~255 minutes.<\/p>\n<p>\u3010Read Format\u3011Set the format for reading data.<\/p>\n<p>Write Address and Read Address data format, 7 consecutive WORDs will be processed every time:<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>WORD 0<\/p>\n<\/td>\n<td>\n<p>Second<\/p>\n<\/td>\n<td>\n<p>0~59<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 1<\/p>\n<\/td>\n<td>\n<p>Minute<\/p>\n<\/td>\n<td>\n<p>0~59<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 2<\/p>\n<\/td>\n<td>\n<p>Hour<\/p>\n<\/td>\n<td>\n<p>0~23<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 3<\/p>\n<\/td>\n<td>\n<p>Day<\/p>\n<\/td>\n<td>\n<p>1~31<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 4<\/p>\n<\/td>\n<td>\n<p>Month<\/p>\n<\/td>\n<td>\n<p>1~12<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 5<\/p>\n<\/td>\n<td>\n<p>Year<\/p>\n<\/td>\n<td>\n<p>0~99<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>WORD 6<\/p>\n<\/td>\n<td>\n<p>Day of Week\t<\/p>\n<\/td>\n<td>\n<p>0~6<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>Note:<\/strong><\/p>\n<p><strong>The value of Sunday is 0.<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.3 Custom<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-012.png\" \/><\/p>\n<p>Figure 49 Unit Setting-Custom<\/p>\n<p>Table 17 Unit Setting-Custom<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Output File Codec\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When the developer has set the export data(Data Log, Alarm, etc.) to the HMI, micro SD Card, or the USB storage, the data format can be selected. The exported file\u2019s data format [Big5(Traditional Chinese), GB18030(Simplified Chinese), UTF-8 encoding] can be chosen such that it satisfies the user\u2019s computer environment.<\/p>\n<p>For example, as the Traditional Chinese Windows environment, open a new project by default as Big5(Traditional Chinese).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010CSV Delimiter\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When the developer has set the export data(Data Log, Alarm, etc.) to the HMI, micro SD Card, or the USB storage, they can choose the CSV file format using either a comma &quot;,&quot;, semicolon &quot;;&quot;, or \u201ctab\u201d as the delimiter.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010File import and export dialog support Traditional Chinese\/Simplified Chinese\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When this option is selected, the system will support Chinese keyboard input for manually entering the file name during runtime.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Default Keypad\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The developer can configure the preset keypad for the operating interface so that this pre-set keypad will pop up when operating text or numeric input objects. Available settings include Decimal Number, Hexadecimal Number, Character and Unicode. <\/p>\n<p><strong>\u3010<\/strong>Controlled by Text Library<strong>\u3011<\/strong><\/p>\n<p>When the customer has a customized keypad and would like to switch to another keypad when switch to another text library, this function should be checked to enable.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Save Location\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When FvDesigner model choose as PC, will appear<strong>\u3010<\/strong>Save Location<strong>\u3011<\/strong>setting option, figure as shown below, this option is mainly to set the default location where FvRT is stored<\/p>\n<p><strong>\u3010<\/strong>Internal<strong>\u3011<\/strong><\/p>\n<p>Set when the FvRT is excuted, if setting export the file to<strong>\u3010<\/strong>Internal<strong>\u3011<\/strong>in the unit setting, the file will be save to the specified location, if this field is empty, then will save to the default location. Is use the default location to store, the system will create a folder the name is same as the project name under the same path.<\/p>\n<p>For example:<\/p>\n<p>The project save in: C:\\Files\\Project11.fpj<\/p>\n<p>then the system defaults to the<strong>\u3010<\/strong>Internal<strong>\u3011<\/strong>storage location:<\/p>\n<p>C:\\Files\\Project11\\run\\storage\\ internal.<\/p>\n<p><strong>\u3010<\/strong>USB Storage<strong>\u3011<\/strong><\/p>\n<p>Set when the FvRT is excuted, if setting export the file to<strong>\u3010<\/strong>USB Storage<strong>\u3011<\/strong>in the unit setting, the file will be save to the specified location.<\/p>\n<p><strong>\u3010<\/strong>microSD Card<strong>\u3011<\/strong><\/p>\n<p>Set when the FvRT is excuted, if setting export the file to<strong>\u3010<\/strong>microSD Card<strong>\u3011<\/strong>in the unit setting, the file will be save to the specified location.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.4 Control Address<\/h4>\n<p>The following control addresses are read from PLC periodically, and set or trigger specific internal functions.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-013.png\" \/><\/p>\n<p>Figure 50 Unit Setting-Control Address<\/p>\n<p>Table 18 Unit Setting-Control Address<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Changing Base Screen by Register Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Control Address\u3011<\/p>\n<p>HMI changes the current screen to target screen, according to the value of register address, the address can be set from HMI internal register and PLC address.<\/p>\n<p>For example: set $U:V202000 to 3, then the screen will change to BS3.<\/p>\n<p>\u3010Reset the Register to Zero\u3011<\/p>\n<p>The value can be reset to 0 after changing screens.<\/p>\n<p>\u3010Synchronize with the Current Base Screen ID\u3011<\/p>\n<p>The value of the register will sane as the ID of the basic screen.<\/p>\n<p>*<strong>note<\/strong>: reset to 0 and synchronize features can not use at the same time.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Read Current Base Screen ID by Register Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The current screen displayed on the HMI will have its screen ID written to the specified register. For example, if the HMI screen is base screen 3, the value of the specified register will be 3.<\/p>\n<p>The screen ID of the current screen can also be read by accessing the value inside the OP_BASE_SCREEN_ID register.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Security Level\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The\u3010security\u3011level can be modified by the value of register address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Command Flags\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Control Address\u3011includes 2 addresses.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-014.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Function<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>WORD 0<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>WORD 1<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Sound <\/strong><\/p>\n<p><strong>Buzzer<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Bit &#8212;&#8212;-0<\/strong><\/p>\n<p>Bit = 0 off<\/p>\n<p>Bit = 1 triggered<\/p>\n<\/td>\n<td>\n<p>WORD 1 = 0  Short Beep<\/p>\n<p>WORD 1 = 1  Long Beep<\/p>\n<p>WORD 1 = 2  Short-Short Beep<\/p>\n<p>WORD 1 = 3  Long-Short Beep<\/p>\n<p>WORD 1 = 4  Continuous Beep<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Backlight On<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Bit &#8212;&#8212;-1<\/strong><\/p>\n<p>Bit = 0 off<\/p>\n<p>Bit = 1 triggered<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Backlight Off<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Bit &#8212;&#8212;-2<\/strong><\/p>\n<p>Bit = 0 off<\/p>\n<p>Bit = 1 triggered<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Screen <\/strong><\/p>\n<p><strong>Saver On\/Off<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Bit &#8212;&#8212;-3<\/strong><\/p>\n<p>Bit = 0 off<\/p>\n<p>Bit = 1 triggered<\/p>\n<\/td>\n<td>\n<p>Reserved<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Status Response\u3011<\/p>\n<p>Return Word 0 trigger status to this address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Screen Capture\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The screenshot file name will be generated based on the date and time, for example : 250102_120526.png<\/p>\n<p>\u3010Control Address\u3011You can assign a Bit address to trigger the screenshot.<\/p>\n<p>\u3010Output\u3011Choose the output destination.<\/p>\n<p>\u3010Format\u3011Select the output file format.<\/p>\n<p>\u3010Prefix of File Name\u3011If you set a prefix such as &quot;AAA&quot;, the resulting filename will be AAA_250102_120526.png. If left blank, no prefix will be added.<\/p>\n<p>\u3010Specific Base Screen ID\u3011When checked, writing a value to the address before triggering will capture a screenshot of the specified screen.<br \/>(Example: To capture BS10, enter 10. Entering 0 or an invalid number will capture the current screen.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Show Window Screen by Register Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Trigger Bit\u3011<\/p>\n<p>This address controls whether to popup window screen.<\/p>\n<p>\u3010Control Address\u3011<\/p>\n<p>This address controls the window screen ID,<\/p>\n<p>For example: $U:V202501=2, then display window screen 2 (WS2)<\/p>\n<p>\u3010Enable Custom Position\u3011<\/p>\n<p>After enabling, you can set the position of the window screen through the register<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Read Current Window Screen ID by Register Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Control Address\u3011<\/p>\n<p>When checked, this address will display the ID of the topmost window screen<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.5 IoT Service<\/h4>\n<p>It provides users to set the connection status of FATEK cloud functions on the HMI and GPS positioning messages of the HMI.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-015.png\" \/><\/p>\n<p>Figure 51 Unit Setting-IoT Service<\/p>\n<p>Table 19 Unit Setting-IoT Service<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010iMonitor Status Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Let user know the current iMonitor connection status through numeric display.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Value(16bit-INT)<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Definition<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Off-line<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>On-line<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Try connecting<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-300<\/p>\n<\/td>\n<td>\n<p>Error: Invalid service password<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-301<\/p>\n<\/td>\n<td>\n<p>Error: The device is not registered in IoT Service<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-302<\/p>\n<\/td>\n<td>\n<p>Error: The device type does not match. Please check the device setting from FATEK IoT.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-400<\/p>\n<\/td>\n<td>\n<p>Error: DNS error. Please check the DNS setting.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Others<\/p>\n<\/td>\n<td>\n<p>TBD<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010iAccess Status Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Let user know the current iAccess connection status through numeric display.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Value(16bit-INT)<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Definition<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Off-line<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>On-line<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Try connecting<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>100<\/p>\n<\/td>\n<td>\n<p>Occupied by IoT Services APP<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>101<\/p>\n<\/td>\n<td>\n<p>Occupied by download<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>102<\/p>\n<\/td>\n<td>\n<p>Occupied by upload<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>103<\/p>\n<\/td>\n<td>\n<p>Occupied by file passthrough<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>105<\/p>\n<\/td>\n<td>\n<p>Occupied by file transfer<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>106<\/p>\n<\/td>\n<td>\n<p>Occupied by viewer<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-100<\/p>\n<\/td>\n<td>\n<p>Error: The LID is used by another device. Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-101<\/p>\n<\/td>\n<td>\n<p>Error: LID is expired. Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-102<\/p>\n<\/td>\n<td>\n<p>Error: Invalid LID. Please contact to your dealer(1)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-103<\/p>\n<\/td>\n<td>\n<p>Error: Invalid LID. Please contact to your dealer(2)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-104<\/p>\n<\/td>\n<td>\n<p>Error: The LID can not support this server. Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-105<\/p>\n<\/td>\n<td>\n<p>Error: The LID can not support HMI. Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-200<\/p>\n<\/td>\n<td>\n<p>System error.(-100) Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-300<\/p>\n<\/td>\n<td>\n<p>Error: Invalid service password.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-301<\/p>\n<\/td>\n<td>\n<p>Error: The device is not registered in IoT Services.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-302<\/p>\n<\/td>\n<td>\n<p>Error: The device type does not match. Please check the device setting from FATEK IoT.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-400<\/p>\n<\/td>\n<td>\n<p>Error: DNS error. Please check the DNS settings.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-10000~-20000<\/p>\n<\/td>\n<td>\n<p>System error. Please contact to your dealer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Others<\/p>\n<\/td>\n<td>\n<p>TBD<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010iLocation (GPS Information)\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Support static and dynamic two types.<\/p>\n<p>GPS format has dddDDDDDDD, dddmmMMMMM, and dddmmssSSS three types.<\/p>\n<p>In static mode, users can set the parameter of the latitude and longitude.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-016.jpg\" \/><\/p>\n<p>In dynamic mode, users can set the GPS coordinate in the specified address.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-017.jpg\" \/><\/p>\n<p>When selecting the dynamic range, the range of values that can be entered is<\/p>\n<p>North Latitude: N (0~900,000,000), South Latitude: S (0~-900,000,000)<\/p>\n<p>East: E (0~1,800,000,000), West longitude: W (0~-1,800,000,000)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-018.jpg\" \/><\/p>\n<p>Or using script(<strong>note<\/strong>: because it is in 32bit-INT, need to use tag)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-019.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IoT Message\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When using HMI to transmit messages to third -party devices via IoT function, it will display the transmission result here.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-020.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.6 Status Bar<\/h4>\n<p>The status bar can assist the user to quickly confirm the status of the HMI.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-021.jpg\" \/><\/p>\n<p>Figure 52 Unit Setting-Status Bar<\/p>\n<p>Table 20 Unit Setting- Status Bar<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Show Status Bar\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set to display the status bar. When this option is selected, the rest of the options are available to configure.<\/p>\n<p>\u3010Show Status Bar By Control Address\u3011<\/p>\n<p>Set a signal to control the status bar visibility.<\/p>\n<p>\u3010Background Color\u3011<\/p>\n<p>Set the background color of the status bar.<\/p>\n<p>\u3010Position\u3011<\/p>\n<p>Select status bar to position. Positions include: up\/down\/left\/right edges.<\/p>\n<p>\u3010Select all\u3011<\/p>\n<p>Select system, peripheral devices, notification, and communication.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System\u3011<\/strong><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Icon<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System Information\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-022.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the device name, station number, firmware version, OS Version, Ethernet, Screen Saver, Date\/Time and other information.<\/p>\n<p>And you can set the HMI ethernet, screen saver and date\/time through this dialog<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\net.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-023.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System Time\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-024.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the system time<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System Date\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-025.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the system date<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Peripheral devices\u3011<\/strong><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Icon<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010HMI Free Space\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-026.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current available storage space and associated percentage.<\/p>\n<p>The number is white when normal and red when less than 10%.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010SD Card Free Space\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-027.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current SD card available storage space, and associated percentage <\/p>\n<p>The number is white when normal and red when less than 10%.<\/p>\n<p>If the HMI cannot detect a SD card it will be display a \u201c?\u201d.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010USB Storage Free Space\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-028.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays USB device\u2019s current available storage space and associated percentage.  <\/p>\n<p>The number is white when normal and red when less than 10%.<\/p>\n<p>If the HMI cannot detect an USB device it will be display \u201c?\u201d.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Notify\u3011<\/strong><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Icon<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Buzzer On\/Off\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-029.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the status of current buzzer on\/off. <\/p>\n<p>The function also can turn on or turn off in HMI \u3010System setting\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Audio On\/Off\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-030.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the status of current audio on\/off. <\/p>\n<p>The function also can turn on or turn off in HMI \u3010System setting\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Alarm Number\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-031.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>This icon will flash when an Alarm occurs.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Backlight level\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-032.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Shows the current HMI backlight brightness<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Communication\u3011<\/strong><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Icon<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010COM1\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-033.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current status of COM1 communication.<\/p>\n<p>The color will display green when communication is normal; the color is red when there is a communication error.(If the link is not set , the color will maintain in green not change). Detail about communication error codes, please refer ch32-Communication Error Codes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010COM3\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-034.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current status of COM3 communication.<\/p>\n<p>The color will display green when communication is normal; the color is red when there is a communication error. (If the link is not set , the color will maintain in green not change). Detail about communication error codes, please refer ch32-Communication Error Codes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010COM4\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-035.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current status of COM4 communication.<\/p>\n<p>The color will display green when communication is normal; the color is red when there is a communication error. (If the link is not set , the color will maintain in green not change). Detail about communication error codes, please refer ch32-Communication Error Codes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010PLC Port\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-036.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current status of PLC Port communication.<\/p>\n<p>The color will display green when communication is normal; the color is red when there is a communication error. (If the link is not set , the color will maintain in green not change). Detail about communication error codes, please refer ch32-Communication Error Codes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Lan\u3011<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-037.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>Displays the current status of Lan communication.<\/p>\n<p>The color will display green when communication is normal; the color is red when there is a communication error. (If the link is not set , the color will maintain in green not change). Detail about communication error codes, please refer ch32-Communication Error Codes<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.2.7 Index Register<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-038.jpg\" \/><\/p>\n<p>Figure 53 Unit Setting-Index Register<\/p>\n<p>Table 21 Unit Setting- Index Register<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Enable Customize Index Register\u3011<\/p>\n<\/td>\n<td>\n<p>Enable index register to use default register or customize, you can define the corresponding address in the address field after enable, it can be HMI internal address or PLC register address, for example, I0 can correspond to PLC R100 address, for designer easy to use, please refer to ch0-<\/p>\n<p>Index Register<\/p>\n<p>for more details about index register.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>3.3 Link<\/h3>\n<p>FATEK HMI can connect to the following types of devices.<\/p>\n<p>Table 22 Device Connection<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Device<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>PLC Device<\/strong><\/p>\n<\/td>\n<td>\n<p>Connecting to the various brands of Device\/PLC Driver.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Printer<\/strong><\/p>\n<\/td>\n<td>\n<p>Connecting to the printer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Video Input<\/strong><\/p>\n<\/td>\n<td>\n<p>Connecting to USB camera.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>USB Barcode Scanner<\/strong><\/p>\n<\/td>\n<td>\n<p>Connecting to USB Barcode Scanner.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.3.1  PLC Device<\/h4>\n<p>Setting up the communication device Device\/PLC: The connection overview will list the information of all the devices connected to the HMI; use the Add\/Edit\/Delete functions to configure the connection device.<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-039.jpg\" \/><\/p>\n<p>Figure 54 Device Connection Setting\u2013PLC Device<\/p>\n<p>Double click on a device in the list to open the device property setting window directly for editing. The interface of sub-link is as shown below.<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-040.png\" \/><\/p>\n<p>Figure 55 Link Properties<\/p>\n<p>Table 23 Link Property Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Basic settings for connection.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Name<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>The name of this connection.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Interface Type<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Transfer method; available selections include Direct Link(Serial), Direct Link(Ethernet), Mult-Link Master(Serial), Mult-Link Master(Ethernetl), Mult-Link Slave(Serial) or Mult-Link Slave(Ethernet).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Manufacturer<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>The manufacturer of the connecting device.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Help<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Look for a detailed description of each brand driver, for example, select FATEK, then show up FATEK PLC related communication settings. Includding communication settings, memory resource review, PLC setting, HMI setting, wiring diagrams, etc. for designers easy to view and use.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Product<\/strong> <strong>Series<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>The product name of the connecting equipment.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Communication interface setup; the interface will change according to the\u3010Interface Type\u3011in\u3010Link Setting\u3011. <\/p>\n<p>When the\u3010Interface Type\u3011is\u3010Direct Link(Serial)\u3011<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\Fv manual\\21.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-041.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Port<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Select the port to connect.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Baudrate<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Select the baud rate.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Parity<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Select the verification method.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Data Bits<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Select the length of the data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Stop Bits<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Select the length of the stop bit.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Timeout (ms)<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>Set the waiting time before ending the connection and generating an error when there is abnormal communication.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Command Delay (ms)<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>The sending and receiving delay for controller signals.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010<strong>Retry Count<\/strong>\u3011<\/p>\n<\/td>\n<td>\n<p>The number of times the HMI will automatically re-send the confirmation signal when there is abnormal communication.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>When\u3010Interface Type\u3011is\u3010Direct Link(Ethernet)\u3011<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\Fv manual\\22.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-042.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the IP address of the device.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the port terminal.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Timeout Time (ms)\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the waiting time before ending the connection and generating an error when there is abnormal communication.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Command Delay (ms)\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The sending and receiving delay for controller signals.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Retry Count\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The number of times the HMI will automatically re-send the confirmation signal when there is abnormal communication.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>\u3010<\/strong>Comm. Error Handling<strong>\u3011<\/strong><\/p>\n<p>Select an action to handle a communication error.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t22_comm. error handing.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-043.jpg\" \/><\/p>\n<p>There are four handling modes as follows:<\/p>\n<ul>\n<li><strong>Process Sequentially<\/strong><\/li>\n<\/ul>\n<p>Process each communication data sequentially. If the data cannot be queried this scanning time, system will re-query it again next time.<\/p>\n<p>The communication error window shows up when communication has failed. User can close the window and continue to operate the current screen.<\/p>\n<p>Show Disconnect Message:<\/p>\n<p>Every time a communication error has occurred, an error message window will pop up. Operation may continue once the error message is closed.<\/p>\n<ul>\n<li><strong>Disconnect<\/strong><\/li>\n<\/ul>\n<p>When a communication error occurs, the links stop communicating. It resets the condition to re-start communication according to Disconnect Setting.<\/p>\n<p><strong>\u3010<\/strong>Disconnect Setting<strong>\u3011<\/strong><\/p>\n<p><strong>Show Disconnect Message:<\/strong><\/p>\n<p>The communication error window shows up when communication has failed. User can close the window and continue to operate the current screen.<\/p>\n<p><strong>Return by Changing Base Screen:<\/strong><\/p>\n<p>The disconnected link restarts communication after changing the base screen.<\/p>\n<p><strong>Return Time:<\/strong><\/p>\n<p>The disconnected link re-starts communication when return time is reached.<\/p>\n<ul>\n<li><strong>Continue<\/strong><\/li>\n<\/ul>\n<p>The communication error window shows up when communication has failed. User can <strong>not<\/strong> close the window and has to stop operating the current screen. When communication is restored, the window closes automatically.<\/p>\n<ul>\n<li><strong>Stop<\/strong><\/li>\n<\/ul>\n<p>The communication error window shows when communication has failed. User can <strong>not<\/strong> close the window and has to stop to operating the current screen. <strong>Retry<\/strong> switch is available to attempt to reestablish communication. When the communication is restored, the window closes automatically.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-044.png\" \/><\/p>\n<p>For more info on communication error codes, refer to Chapter 32-Communication Error Codes <\/p>\n<p><strong>\u3010<\/strong>Advanced<strong>\u3011<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-045.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Automatic Station Number\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>FATEK PLC only, it will automatically read the station number, but will not be able to use the sub-link function.<strong> (The connected PLC needs to be checked without checking the station number)<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Maximal Gap\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the maximal gap for each read command. For example, there are D0, D5, D100, D102 four numeric display object, and the maximal gap is 10, then D0 and D5 will be composed of a read communication command, and D100 and D102 will be composed of another read communication command, because the maximal gap is 10.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device Specific Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Configuration setting of the equipment.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t22_device setting.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-046.jpg\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device Name\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the name of the equipment.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Station Number\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the station number of the connection equipment.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Set in Register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The station number communicated with the connection equipment can be dynamically set by the HMI internal register. For example, set $U:V10, and $U:V10=1, then it will communicate with station no.1, during the HMI run time, when $U:V10=5, then it will communication with station no.5. after select this option, except setting the default register, there is\u3010Default Number\u3011below you can set, for example, set 3, download the project for the first time will be station no.3 to communicate with the link equipment, then it will communicate with the \u3010Register\u3011value after that.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Status\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Display the link status, you can set default register after selected, if set $U:V30:<\/p>\n<p>$U:V30=0x0000 indicates that the connection is normal. $U:V30=0x0001 indicates that the connection is abnormal.<\/p>\n<p>$U:V30=0x8000 indicates that the connection is disconnect.<\/p>\n<p><strong>\u203bWhen Modbus Slave is selected, the connection status stores the number of connections of the Modbus slave.<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable\/Disable Link in Register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The connected devices can be dynamically set by HMI internal register whether to enable or disable, provide maintenance personnel or operators can decide whether to connect with the device during HMI execution.<\/p>\n<p>Ex: set $U:V10.0, when $U:V10.0 = ON, then it will communicate with this device, <\/p>\n<p>when $U:V10.0 = OFF, then it will not communicate with this device<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Sub-links\u3011<\/p>\n<p>When \u3010Sub-links\u3011 is not selected, the system operates in a 1-to-1 connection mode. When \u3010Sub-links\u3011 is selected, 1-to-multiple connections are supported.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t22_sublinks.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-047.jpg\" \/><\/p>\n<p>\u3010Sub-links\u3011Architecture Diagram<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-048.jpg\" \/><\/p>\n<p>As shown in the diagram above, the sub-link function allows multiple devices of the same model to be connected using the same communication method.<\/p>\n<p>Please note:<br \/>If \u3010Interface Type\u3011 is set to \u3010Ethernet\u3011, only modules that support Ethernet-to-serial conversion (such as FBs-CM25E or FBs-CM55E) are compatible with Ethernet sub-link connections.<\/p>\n<p>Set as figure, device name 0 communicate with station no.1 link device, device name 1 , enable\u3010Set Station Number in Register\u3011dynamically decision by $U:V20, for example, $U:V20=5, then it will communicate with station no.5 link device and enable default number as 5, device name 2 communicate with station no.3 link device and enable link status, enable\u3010Link Status\u3011when $U:V40=0 indicates that the connection is normal, when $U:V40=1 indicates that the connection is abnormal.<\/p>\n<p>Device name 3 communicate with station no.4, then enable\u3010Enable\/Disable Link in Register\u3011, when $U:V51.0 = ON will communicate with this device, when $U:V51.0 = OFF will not communicate with this device<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>3.3.1.1 Input Address Configuration Settings<\/h5>\n<p>In the \u3010Input Address\u3011section, you can open the device dropdown menu and select a previously created device from the \u3010Link\u3011list.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-049.png\" \/><\/p>\n<p>Figure 56 PLC Input Address Setting Dialog<\/p>\n<p>Table 24 Access Address Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Register address inside the HMI\/PLC device. After selecting the connection, the address will display the register pattern for the designer to choose from and fill in the address of the pattern. Fill addresses in sequentially and the legal addresses will be displayed in green and illegal ones in red. This ensures correct addresses will always be entered.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Device where the register is located.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Type\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Device type of the register.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Register address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Index Register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Index register setting. Selecting this option means using the index register. The last number(s) in the address is the index register address.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-050.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Special register address inside the HMI. The address type displays information on the register function and the corresponding register address of the function.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Item<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System Tag\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The system\u2019s default register tag.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The corresponding register address of the system tag.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Description\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Describe the function of the system tag.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-051.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Tag\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Use the tags defined in the custom tag library.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-052.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Use Index Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Please refer to the section 23.2-Index Register<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.3.2  Printer<\/h4>\n<p>A printer can be connected to the HMI and can print out HMI screen captures or other information. To print, a printer has to be configured through selecting type of printer to connect and the port on the HMI it is connected to. Printing can also be controlled through a control address. See <strong>Chapter 19.4.2.4 -\u3010Function<\/strong> <strong>Switch\u3011<\/strong>for more details.<\/p>\n<p>The\u3010Printer\u3011settings page is shown below. Each option is explained.<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-053.jpg\" \/><\/p>\n<p>Figure 57\u3010Printer\u3011Settings Screen<\/p>\n<p>Table 25\u3010Printer\u3011Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Printer\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check to enable printer configuration.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Type\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Support USB and serial two types, when the project model is PC , the PC Default Printer can be selected.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Model\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010USB\u3011- PictBridge<\/p>\n<p>Use mini-USB to connect to pictbridge printers. The following models are available for reference, but the settings may be slightly different between brands. There is no guarantee that the HMI can support all printer models.<\/p>\n<p><a href=\"http:\/\/www.cipa.jp\/pictbridge\/CertifiedModels\/PictBridgeCertifiedModels_E.html#PRT_BENQ\">http:\/\/www.cipa.jp\/pictbridge\/CertifiedModels\/<br \/>PictBridgeCertifiedModels_E.html#PRT_BENQ<\/a><\/p>\n<p>\u3010Serial\u3011- Argox PPLB, EPSON ESC\/POS, SPRT A Series<\/p>\n<p>Argox PPLB- label printer<\/p>\n<p>EPSON ESC\/POS- Dox matrix\/pos printer<\/p>\n<p>SPRT A Series- SPRT\u2019s A series printer<\/p>\n<p>\u3010PC Default Printer\u3011<\/p>\n<p>Print through the PC default printer.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Settings\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Basic\u3011<\/p>\n<p>Set the related port parameter.<\/p>\n<p>\u3010Advanced\u3011<\/p>\n<p>Set the encoding to communicate with the printer (EPSON only needs to be aware of), and print zoom and whether to cut.<\/p>\n<p>\u3010Print Screen Setting\u3011<\/p>\n<p>Set the Print Method, Inverted Image, and Orientation.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>3.3.2.1  Argox PPLB tutorial<\/h5>\n<p>By using Argox Company provided software ArgoBar Pro to generate .prn file then import it to FvDesigner, allows FvDesigner and HMI to do tags editing. Currently only support PPLB series tag.<\/p>\n<p>ArgoBar Pro offical download and simple tutorial: <a href=\"https:\/\/reurl.cc\/D15d0e\">https:\/\/reurl.cc\/D15d0e<\/a> <\/p>\n<ol>\n<li>Build project<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-054.png\" \/><\/p>\n<p>Select PPLB 200dpi, Printing Options select Printer Command, or it may show format error after import tags.<\/p>\n<ol>\n<li>Set up the tag for replacement<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-055.png\" \/><\/p>\n<p>Currently we only support the following three functions:<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Text\u3011<\/p>\n<\/td>\n<td>\n<p>Font: Need to select PPLB Font type so when importing the .prn file the FvDesigner will support the label replace function. If the font type is in TrueType, the file will be viewed as an image but not replaceable words.<\/p>\n<p>String: The &#8216;Text String&#8217; field can only text English if text Chinese then the file will be viewed as image and can not be replaced after import to FvDesigner.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Barcode\u3011<\/p>\n<\/td>\n<td>\n<p>Just follow the ArgoBar Pro software attention.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010QR Code\u3011<\/p>\n<\/td>\n<td>\n<p>Just follow the ArgoBar Pro software attention.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<ol>\n<li>Output file<\/li>\n<\/ol>\n<p>Click &#8216;print&#8217; and check the checkbox &#8216;print to file&#8217; to output the .prn file.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-056.png\" \/><\/p>\n<ol>\n<li>Import to FvDesigner<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-057.png\" \/><\/p>\n<p>Click add button to import .prn file then the label properties can be set.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-058.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010General\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Label ID\u3011<\/p>\n<p>Set a number to the label for printing.<\/p>\n<p>\u3010Label Name\u3011<\/p>\n<p>Name the label.<\/p>\n<p>\u3010Comment\u3011<\/p>\n<p>Add comment for the label.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Mapping Table\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Alias\u3011<\/p>\n<p>Name the field.<\/p>\n<p>\u3010Label Type\u3011<\/p>\n<p>Tags set in the ArgoBar Pro.<\/p>\n<p>\u3010Original Data\u3011<\/p>\n<p>Default value to be displayed.<\/p>\n<p>\u3010Data Type\u3011<\/p>\n<p>Text(Static Word), Dataitem(Time), and Register.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.3.3  Video Input<\/h4>\n<h5>3.3.3.1 USB Camera<\/h5>\n<p>When the project wants to connect to USB Camera need to set the settings here first so that the video input display can do action, for more detail please refer to ch19.4.35-\u3010Video Input Display\u3011, in addition, when the alarm occurs, photos taken by the camera can also be sent to designated person via email, for more detail please refer to ch8.3-Alarm Application Example, this function only support after OS v1.0.14 or PC version.<\/p>\n<p>If the HMI and the camera disconnected, change to another page and return for retry connection.<\/p>\n<p><strong>Note 1: This function only support in P5 all series HMI.<\/strong><\/p>\n<p><strong>Note 2: This function only sipport HMI OS version 1.0.14 or later and PC version.<\/strong><\/p>\n<p><strong>Note 3: This function has been tested it support MJPEG format.<\/strong><\/p>\n<p><strong>Note 4: Currently has tested successful for supporting the following 3 USB cameras<\/strong><\/p>\n<ul>\n<li><strong>Logitech: C270<\/strong><\/li>\n<li><strong>Logitech: C922 HD 1080P<\/strong><\/li>\n<li><strong>Microsoft: LifeCam HD-3000<\/strong><\/li>\n<\/ul>\n<p>The\u3010Video Input\u3011settings page is shown below. Each option is explained.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-059.png\" \/><\/p>\n<p>Figure 58<strong>\u3010<\/strong>Video Input<strong>\u3011<\/strong>Setting Window<\/p>\n<p>Table 26\u3010Video Input\u3011property settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Options<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Basic\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Enable USB Camera\u3011<\/p>\n<p>Set whether to enable USB camera function.<\/p>\n<p>\u3010Size\u3011<\/p>\n<p>Set the size of the video input display, whether the selected size is available depends on the camera support.<\/p>\n<p>\u3010Speed\u3011<\/p>\n<p>Set the screen update speed, it will take up more HMI system resources if select fast.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Control\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Auto Connect to Camera\u3011<\/p>\n<p>Set whether to Auto Connect to Camera function.<\/p>\n<p>\u3010Enable Control Word\u3011<\/p>\n<p>Control the video input display through control word, whether the control is available depends on the camera support.<\/p>\n<p>\u3010Argument Word\u3011<\/p>\n<p>When control word is enabled, argument word is the parameter to change the control of camera.<\/p>\n<p>When control word or argument word have changed, the setting will be written.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Function<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Control Word<\/strong><\/p>\n<p><strong>(Hex)<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Argument Word<\/strong><\/p>\n<p><strong>(Hex)<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Play<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0001<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Pause<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0002<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Stop<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0003<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Contrast<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0100<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Brightness<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0101<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Saturation<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0102<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Hue of the Image<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0103<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Gamma Value of the Image<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0104<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Gain<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0105<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Sharpness<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0107<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Backlight Compensation<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0108<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image White Balance Temperature<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0109<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Enable the Image White Balance Temperature<\/strong><\/p>\n<\/td>\n<td>\n<p>0x010A<\/p>\n<\/td>\n<td>\n<p>1 : Enable; <\/p>\n<p>0 : Disable; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Adjust the Image Exposure Value<\/strong><\/p>\n<\/td>\n<td>\n<p>0x010B<\/p>\n<\/td>\n<td>\n<p>0-100 : The percentage value is between the minimum and the maximum; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Enable the Image Exposure<\/strong><\/p>\n<\/td>\n<td>\n<p>0x010C<\/p>\n<\/td>\n<td>\n<p>1 : Enable; <\/p>\n<p>0 : Disable; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Enable Image Flip Horizontal<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0110<\/p>\n<\/td>\n<td>\n<p>1 : Enable; <\/p>\n<p>0 : Disable; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Enable Image Flip Vertical<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0111<\/p>\n<\/td>\n<td>\n<p>1 : Enable; <\/p>\n<p>0 : Disable; <\/p>\n<p>255:Reset<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Reset Image<\/strong><\/p>\n<\/td>\n<td>\n<p>0x01FF<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Save Image to Internal Memory<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0200<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Save Image to USB Flash<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0201<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Save Image to SD Card<\/strong><\/p>\n<\/td>\n<td>\n<p>0x0202<\/p>\n<\/td>\n<td>\n<p>N\/A<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Enable Response Word\u3011<\/p>\n<p>Display whether the video iuput display was enable success or the result of control word setting.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Hex<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p><strong>Normal<\/strong><\/p>\n<\/td>\n<td>\n<p>No Error<\/p>\n<\/td>\n<td>\n<p>0x0000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>connected<\/p>\n<\/td>\n<td>\n<p>0x8001<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">\n<p><strong>Error<\/strong><\/p>\n<\/td>\n<td>\n<p>HMI no support<\/p>\n<\/td>\n<td>\n<p>0x0100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>No device<\/p>\n<\/td>\n<td>\n<p>0x0101<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Device initialization failed<\/p>\n<\/td>\n<td>\n<p>0x0102<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Device disconnected<\/p>\n<\/td>\n<td>\n<p>0x0103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control_device is not initialized<\/p>\n<\/td>\n<td>\n<p>0x0200<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control_Unsupported<\/p>\n<\/td>\n<td>\n<p>0x0201<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control _ wrong value<\/p>\n<\/td>\n<td>\n<p>0x0202<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control _ Busy<\/p>\n<\/td>\n<td>\n<p>0x0203<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control _ read only<\/p>\n<\/td>\n<td>\n<p>0x0204<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control _ input error<\/p>\n<\/td>\n<td>\n<p>0x0205<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Control _ archive failed<\/p>\n<\/td>\n<td>\n<p>0x0300<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>unknown mistake<\/p>\n<\/td>\n<td>\n<p>0x0FFF<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Save Image File Mode\u3011<\/p>\n<ul>\n<li>\u3010Limit Mode\u3011<br \/>When using the control word to save the file, the old files will be overwritten if the number of the files are over the limitation.<\/li>\n<li>\u3010Time Mode\u3011<\/li>\n<\/ul>\n<p>When using the control word to save the file, there is no limit for the numbers of the files, but it can no longer save the file if the storage space is not enough.<\/p>\n<p>The file name format would be the current date and time yyMMdd_hhmmss.jpg<\/p>\n<p>(For example: 200702_145018.jpg).<\/p>\n<p>\u3010Save Image File Limit\u3011<\/p>\n<p>This option will be displayed under\u3010Limit Mode\u3011, and the range of the saving files is 0~999.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>3.3.3.2 IP Camera <\/h5>\n<p>Available after V1.7.20. This feature is supported only on G03 or higher HMI models or when running on FvRT. This section explains how to enable the function. For component details, please refer to \u200e<\/p>\n<p>19.4.36 \u2013 &quot;Network Camera Player.&quot;<\/p>\n<ul>\n<li>The computer must have DirectX 11 or later installed to use GPU acceleration. (Windows 10 and Windows 11 come with DirectX 12 installed by default. If DirectX is not installed, all image processing will be handled by the CPU, which may result in high CPU usage.)<\/li>\n<li>The computer must have Microsoft Media Foundation installed.<\/li>\n<li>This feature supports PTZ. PTZ stands for Pan (horizontal rotation), Tilt (vertical rotation), and Zoom. The camera must support the relevant ONVIF certification (Profile S) and be equipped with physical motors (such as a speed dome camera) to allow remote PTZ control and lens direction adjustment. Available PTZ functions may vary depending on the camera model.<\/li>\n<li>If playback does not work at all, it may indicate that the computer system does not support media playback functionality.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-060.png\" \/><\/p>\n<p>Figure 59<strong>\u3010<\/strong>IP Camera<strong>\u3011<\/strong>Setting Window<\/p>\n<p>Table 27\u3010IP Camera\u3011property settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Options<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Name\u3011<\/p>\n<\/td>\n<td>\n<p>Item Name, you may enter any name freely.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010RTSP URL\u3011<\/p>\n<\/td>\n<td>\n<p>Click the Edit button to open the editing window for input. The RTSP Address Editor provides format guidelines, and after confirmation it will perform a validation check to ensure the device is valid. It can verify whether the RTSP IP address is valid, whether the device is a camera, and whether it supports PTZ.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-061.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010PTZ Control\u3011<\/p>\n<\/td>\n<td>\n<p>You can configure whether to enable PTZ control. The user must enter a username and password.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-062.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Notice\u3011<\/p>\n<\/td>\n<td>\n<ul>\n<li>Only network cameras that support the RTSP protocol are supported. Please confirm the device specifications and information provided by the manufacturer.<\/li>\n<li>The RTSP URL can be constructed according to the format instructions or obtained from the manufacturer\u2019s documentation.<\/li>\n<li>It is recommended to use network cameras that are ONVIF-certified to ensure compatibility.<\/li>\n<li>Some network cameras do not have ONVIF enabled by default. Please verify that this feature is enabled in the device settings.<\/li>\n<li>\uf0b7  When using the PTZ function, make sure the camera itself supports PTZ and is compatible with ONVIF (such as Profile S or later), and that you enter an account with PTZ control permissions.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.3.4 USB Barcode Scanner<\/h4>\n<p>Scan the barcode and display the information on the numerical input display.<\/p>\n<p>Please note that this function is a mandatory address setting, so after enabling this function, the numeric and text input display cannot use the<strong>\u3010<\/strong>USB Barcode Scanner<strong>\u3011<\/strong>function.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-063.png\" \/><\/p>\n<p>Figure 60<strong>\u3010<\/strong>USB Barcode Scanner<strong>\u3011<\/strong>Setting Window<\/p>\n<p>Table 28<strong>\u3010<\/strong>USB Barcode Scanner<strong>\u3011<\/strong>property settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Read Byte Limit\u3011<\/p>\n<\/td>\n<td>\n<p>Set the maximum data that can be displayed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Storage Start Address\u3011<\/p>\n<\/td>\n<td>\n<p>Set the storage address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Receive Completion Bit\u3011<\/p>\n<\/td>\n<td>\n<p>The bit will be true when scanning complete.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Each character occupies one word(two bytes)\u3011<\/p>\n<\/td>\n<td>\n<p>Set whether to enable one character per character.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>3.3.5 RFID Reader<\/h4>\n<p>This feature currently only communicates with &quot;HEM-WLC-RFID&quot;. Please visit <a href=\"https:\/\/www.fatek.com\/en\/download.php?act=list&amp;cid=28\">https:\/\/www.fatek.com\/en\/download.php?act=list&amp;cid=28<\/a>  to view the specifications.<\/p>\n<h5>3.3.5.1 Enable RFID Reader<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-064.png\" \/><\/p>\n<p>Figure 61\u3010RFID\u3011Setting Window<\/p>\n<p>Table 29\u3010RFID\u3011property settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Basic\u3011<\/p>\n<\/td>\n<td>\n<p>Setting up communication with the RFID device. <\/p>\n<p>The connection method for &quot;HEM-WLC-RFID&quot; is RS-485.<\/p>\n<p>Parameter is\u3010Baud Rate\u3011: 9600,\u3010Parity\u3011: None,\u3010Data Bits\u3011: 8,\u3010Stop Bits\u3011: 1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010General\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Write Card Uid To Address\u3011The data read from the card will be displayed at the specified address.<\/p>\n<p>\u3010Receive Completion Bit\u3011When the card reader is triggered, this bit will also be triggered, and it will not automatically reset.<\/p>\n<p>\u3010Reader Error Code\u3011If there is an abnormality in the data read by the card reader, an error code will be displayed.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-1<\/p>\n<\/td>\n<td>\n<p>Reader data format error. (The HMI received data in an unresolvable format.)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-2<\/p>\n<\/td>\n<td>\n<p>Card data is illegal. (The data checksum check failed.)<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Induction Method\u3011<\/p>\n<p>\u3010Auto\u3011In automatic mode, the card will be read simply by bringing it close to the card reader.<\/p>\n<p>\u3010Trigger\u3011The card reader will only fetch data when the card is brought close to it and the trigger bit is triggered.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>3.3.5.2 RFID Advance functions<\/h5>\n<p>In the advanced functions, users can integrate with the <strong>\u3010Security\u3011<\/strong> feature. For example, to use the RFID advanced function, the mode in <strong>\u3010Security\u3011<\/strong>must be changed to <strong>\u3010User\u3011<\/strong>. There are a total of 4 operation modes supported in the advanced functions: <strong>\u3010Read Mode\u3011<\/strong>, <strong>\u3010Register Mode\u3011<\/strong>, <strong>\u3010Remove Mode\u3011<\/strong>, and <strong>\u3010Edit Mode\u3011<\/strong>.<\/p>\n<p><strong>\u3010Read Mode\u3011<\/strong>: This is the default mode. When the card reader reads a card number, the status of this card number will be displayed in the <strong>\u3010Read Result\u3011<\/strong>.<\/p>\n<p><strong>\u3010Register Mode\u3011<\/strong>: Binds the card number to a specific username.<\/p>\n<p><strong>\u3010Remove Mode\u3011<\/strong>: Unbinds the card number.<\/p>\n<p><strong>\u3010Edit Mode\u3011<\/strong>: Modifies the active status of the card number.<\/p>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-065.png\" \/><\/p>\n<p>Figure 62 Advanced Setting Screen for\u3010RFID\u3011\u3010Security\u3011<\/p>\n<p>Table 30 Advanced Setting Properties\u3010RFID\u3011<strong>\u3010<\/strong>Security\u3011 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Item<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Cardholder Data Read\/Write\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Card Uid\u3011Specifies the address of the card number to be operated, with a maximum of 16 characters.<\/p>\n<p>\u3010Username Type\u3011Selects the format of the username.<\/p>\n<p>\u3010Username\u3011Sets the username to be operated, which must be the same as the user set in\u3010Security\u3011.<\/p>\n<p>\u3010Password\u3011Sets the password of the user being operated, which must match the\u3010Security\u3011settings for authentication.<\/p>\n<p>\u3010Security Level\u3011Displays the security level of the user bound to the card.<\/p>\n<p>\u3010Card Active Status\u3011Sets the active status of the card, with 0 for disabled and 1 for enabled.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Operate\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Mode Control\u3011Sets the operation mode.<\/p>\n<p>\u3010Trigger\u3011Switches the operation mode after being triggered.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Read Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Register Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Remove Mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>Edit Mode<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Read Result\u3011When the current mode is\u3010Read\u3011, the read result will be displayed here. In Read Mode, the result is displayed whenever a card is scanned, without additional trigger bits. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Read successfully<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-1<\/p>\n<\/td>\n<td>\n<p>Card Uid is empty (usually caused by improper card placement leading to failure to read)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-2<\/p>\n<\/td>\n<td>\n<p>This card not registered<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-3<\/p>\n<\/td>\n<td>\n<p>This card has been disabled<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Excute\u3011When selecting\u3010Register\u3011,\u3010Remove\u3011,\u3010Edit\u3011, the function is executed by triggering this bit.<\/p>\n<p>\u3010Excution Result\u3011The result of triggering the execution bit will be displayed here.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>The data has not changed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Excuted successfully<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-1<\/p>\n<\/td>\n<td>\n<p>Card uid is empty  (usually due to improper placement of the card)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-2<\/p>\n<\/td>\n<td>\n<p>Username is required<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-3<\/p>\n<\/td>\n<td>\n<p>Passwrd is required<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-4<\/p>\n<\/td>\n<td>\n<p>Invalid level (less than 0 or greater than 15)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-5<\/p>\n<\/td>\n<td>\n<p>Invalid card active status (not 1 or 0)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-6<\/p>\n<\/td>\n<td>\n<p>This card has been used by other user<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-7<\/p>\n<\/td>\n<td>\n<p>Password does not match user<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-8<\/p>\n<\/td>\n<td>\n<p>Card does not match user<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-9<\/p>\n<\/td>\n<td>\n<p>This card is not linked to the user<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-10<\/p>\n<\/td>\n<td>\n<p>Permission denied (cannot operate users with higher login levels)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-11<\/p>\n<\/td>\n<td>\n<p>Administrator security operations are not enabled<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Receive Completion Bit\u3011<\/p>\n<\/td>\n<td>\n<p>The bit will be true when scanning complete.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Each character occupies one word(two bytes)\u3011<\/p>\n<\/td>\n<td>\n<p>Set whether to enable one character per character.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u203bIn addition to using <strong>\u3010Operation\u3011<\/strong> to modify the mode, you can also use <strong>\u3010Function Switch\u3011<\/strong> to modify it.<\/p>\n<h5>3.3.5.3 Advance functions operation procedure<\/h5>\n<p><strong>\u3010Read Mode\u3011<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-066.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>\u3010Register Mode\u3011<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-067.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>\u3010Remove Mode\u3011<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-068.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>\u3010Edit Mode\u3011<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-03\/p5hmi-fvd-en-03-069.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Click on the setting option in\u3010System\u3011and the related s [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3345","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3345"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3345\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3345"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3345"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}