{"id":3346,"date":"2026-11-17T18:42:36","date_gmt":"2026-11-17T10:42:36","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-04\/"},"modified":"2026-11-17T18:42:36","modified_gmt":"2026-11-17T10:42:36","slug":"p5hmi-fvd-en-04","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-04\/","title":{"rendered":"Chapter 4 Servers"},"content":{"rendered":"<p>This chapter will introduce the various server functions provided by the HMI; users can use these server functions to achieve needs such as remote file access , send email and remote screen control.<\/p>\n<h3>4.1 \u3010FTP Server\u3011<\/h3>\n<p>FTP Server allows users to access files on the internal storage, SD card and USB storage device of the HMI. There are two ways to deploy the FTP server on the HMI. One is through the system settings of the HMI and the other is through the projects settings. Project settings will override system settings at project startup.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-001.jpg\" \/><\/p>\n<p>Figure 63 FTP Application Diagram<\/p>\n<h4>4.1.1  Deploying FTP Server using System Settings of HMI<\/h4>\n<p>The following screen will appear when the\u3010Server Settings\u3011page in the system settings of the HMI is opened:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-002.jpg\" \/><\/p>\n<p>Figure 64 FTP Servers Setting\u2013HMI<\/p>\n<p>The following are the descriptions of each field in the figure above:<\/p>\n<p>Table 31 FTP Server Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Field<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable FTP Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set to enable the FTP server; other fields can only be accessed when FTP Server is enabled.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Specify the port to listen for FTP Server; the default port is 21.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable Read-Only Account\u3011<\/strong><\/p>\n<p><strong>\u3010User Name\u3011<\/strong><\/p>\n<p><strong>\u3010Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set to enable read-only accounts. A user name and password pair can be created once this option is enabled. Users who log in to FTP Server with this account can only read files and cannot perform operations including creating, modifying or deleting files.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable Read-Write Account\u3011<\/strong><\/p>\n<p><strong>\u3010User Name\u3011<\/strong><\/p>\n<p><strong>\u3010Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set to enable read-write accounts. A user name and password pair can be created once this option is enabled. Users who log in to FTP Server with this account can access files as well as perform operations including creating, modifying or deleting files.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mask Passwords\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p> Set if the password is to be encrypted.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.1.2 Deploying FTP Server using Project Settings<\/h4>\n<p>Click on\u3010Server\u3011in the\u3010System\u3011window of the\u3010Project Explorer\u3011to the left of FvDesigner to enter the\u3010Server\u3011settings screen where the\u3010FTP\u3011tab page can be used to setup FTP Server, as shown in the figure below:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-003.png\" \/><\/p>\n<p>Figure 65 FTP Server Setting\u2013Project<\/p>\n<p>The FTP settings of the project can be used to override HMI\u3010System Setting\u3011FTP Server settings on the HMI when the project is loaded if\u3010Overwrite FTP Configuration on HMI\u3011is checked. The other settings are identical to the setting screen on the HMI; please refer to the explanations in <strong>Chapter 24.2.4-\u3010Servers\/IoT\u3011<\/strong>.<\/p>\n<p><strong>Note: if HMI has enable FTP sever, but the project setting doesn\u2019t enable FTP server, then the FTP sever will be disable when download the project.<\/strong><\/p>\n<h4>4.1.3  FTP Server Example<\/h4>\n<p>We will use the following steps to illustrate how to use FTP Server:<\/p>\n<ol>\n<li>Enter the system settings of the HMI during boot up and then open\u3010Server Settings\u3011; setup FTP Server as shown in <strong>Figure 481.<\/strong><\/li>\n<li>Use Windows Explorer to open the address:<a href=\"ftp:\/\/user:password@hmi\/\">ftp:\/\/user:password@HMI IP Address<\/a> to see the files on the HMI, as shown in the figure below:<\/li>\n<\/ol>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\233.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-004.jpg\" \/><\/p>\n<p>Figure 66 Using FTP to view files stored in internal memory, SD, or USB<\/p>\n<h3>4.2 \u3010VNC Server\u3011<\/h3>\n<p>VNC Server allows users to remotely view and operate the HMI functions through an Internet connection so that users can check the data on the HMI or operate the HMI remotely. There are two ways to deploy the VNC server on the HMI. One is through the system settings of the HMI and the other is through the project settings. Project settings will have a higher priority if both settings are set.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-005.jpg\" \/><\/p>\n<p>Figure 67 VNC application illustration<\/p>\n<h4>4.2.1  Deploying VNC Server using System Settings of HMI<\/h4>\n<p>The following screen will appear when the\u3010Server Settings\u3011page in the system settings interface of the HMI is opened:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-006.jpg\" \/><\/p>\n<p>Figure 68 VNC Server Setting-HMI<\/p>\n<p>The following are the descriptions of each field in the figure above:<\/p>\n<p>Table 32 VNC Server Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Field<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable VNC Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set to enable the VNC server; other fields can only be set when the VNC server is enabled.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connections\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set how many VNC clients can be connected to this VNC server, the maximum number of support will vary depending on the model.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mask Passwords\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set if the password is to be encrypted.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the VNC port, can only set the first client port, the second will automatically increase, for example, the first set 5900, the second will be 5901.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The password used to login to the VNC server.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.2.2  Deploying VNC Server using Project Settings<\/h4>\n<p>Click on\u3010Server\u3011in the\u3010System\u3011window of the\u3010Project Explorer\u3011to the left of FvDesigner to enter the\u3010Server\u3011settings, in which the\u3010VNC\u3011tab page can be used to set the VNC server, as shown in the figure below:<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\236.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-007.jpg\" \/><\/p>\n<p>Figure 69 VNC Server Setting-Project<\/p>\n<p>The VNC settings of the project can be used to override the VNC server settings when the project is loaded if\u3010Overwrite VNC Configuration on HMI\u3011is checked. The other settings are identical to the setting screen on the HMI; please refer to the explanations in <strong>Chapter 24.2.4 -\u3010Servers\/IoT\u3011<\/strong>.<\/p>\n<h4>4.2.3 VNC Server Example<\/h4>\n<p>We will use the following steps to illustrate how to use the VNC server:<\/p>\n<ol>\n<li>Install a VNC client software; VNC Viewer 6.1.7(<a href=\"https:\/\/www.realvnc.com\/download\/viewer\/\">https:\/\/www.realvnc.com\/download\/viewer\/<\/a>) by RealVNC is used in this example.<\/li>\n<li>The following screen can be seen once VNC Viewer is opened and add link:<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-008.jpg\" \/><\/p>\n<p>Figure 70 VNC Viewer Connection Screen<\/p>\n<p>Press Connect after entering the IP of the HMI, and a prompt will appear asking the user to enter the password:<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\238.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-009.jpg\" \/><\/p>\n<p>Figure 71 VNC Viewer Password Confirmation Screen<\/p>\n<ol>\n<li>Press OK after entering the password and real-time screens on the HMI can be seen.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-010.jpg\" \/><\/p>\n<p>Figure 72 VNC Viewer remote monitor screen<\/p>\n<p><strong>Note: Please adjust the settings of the VNC Viewer if the HMI screens did not appear after entering the correct password; just set the value of FullColor in Options-&gt;Advanced-&gt;Expert to True.<\/strong><\/p>\n<h3>4.3 \u3010SMTP\u3011<\/h3>\n<p>SMTP(Simple Mail Transfer Protocol), is a widely used protocol for sending mail over the Internet, this chapter will describe how to set to let user can send the email through HMI. For example, when an alarm occurs, an alarm message can be immediately sent to an operator or a designated e-mail recipient, so that the operator can handle and maintain the major issues that occur in the device.<\/p>\n<h4>4.3.1 \u3010SMTP\u3011setting<\/h4>\n<p>The function is on the left side of FvDesigner, is in\u3010Project Explorer\u3011\u3010System\u3011\u3010Servers\u3011setting page, figure as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-011.png\" \/><\/p>\n<p>Figure 73\u3010Sever\u3011\u3010SMTP\u3011setting paging<\/p>\n<p>Table 33\u3010Sever\u3011\u3010SMTP\u3011setting property<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Field<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Enable SMTP\u3011<\/p>\n<\/td>\n<td>\n<p>Decide whether to enable SMTP function, check to set the following fields.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010SMTP Setting\u3011<\/p>\n<\/td>\n<td>\n<p>Set the server, port, user, encryption and password of\u3010SMTP\u3011<\/p>\n<p>\u3010Server\u3011<\/p>\n<p>The sending email server, the following table shows common mail servers for reference , please refer to the various mail server announcements . <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Email<\/p>\n<\/td>\n<td>\n<p>SMTP Server<\/p>\n<\/td>\n<td>\n<p>Port<\/p>\n<\/td>\n<td>\n<p>Encryption<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Gmail<\/p>\n<\/td>\n<td>\n<p>smtp.gmail.com<\/p>\n<\/td>\n<td>\n<p>465 <\/p>\n<\/td>\n<td>\n<p>SSL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Hotmail<\/p>\n<\/td>\n<td>\n<p>smtp.live.com<\/p>\n<\/td>\n<td>\n<p>587<\/p>\n<\/td>\n<td>\n<p>TLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Yahoo<\/p>\n<\/td>\n<td>\n<p>smtp.mail.yahoo.com<\/p>\n<\/td>\n<td>\n<p>465<\/p>\n<\/td>\n<td>\n<p>SSL<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>AOL<\/p>\n<\/td>\n<td>\n<p>smtp.aol.com<\/p>\n<\/td>\n<td>\n<p>587<\/p>\n<\/td>\n<td>\n<p>TLS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>QQ<\/p>\n<\/td>\n<td>\n<p>smtp.qq.com<\/p>\n<\/td>\n<td>\n<p>465<\/p>\n<\/td>\n<td>\n<p>SSL<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>Note: If using gmail server, users should set the 2-step verification and generate the app password.<\/strong><\/p>\n<p><strong>(Setting instruction: <\/strong><a href=\"https:\/\/support.google.com\/mail\/answer\/185833\">https:\/\/support.google.com\/mail\/answer\/185833<\/a><strong>)<\/strong><\/p>\n<p>\u3010Port\u3011<\/p>\n<p>Each e-mail mail server has different connection ports. Please refer to the above table or check the mail server announcements.<\/p>\n<p>\u3010Encryption\u3011<\/p>\n<p>Each email mail server has different encryption ways. Please refer to the above table or check the mail server announcements. <\/p>\n<p>\u3010My SMTP server needs to be verified\u3011<\/p>\n<p>If this function is checked, the user name and password should be entered, the actual usage depends on the connected server.<\/p>\n<p>\u3010User\u3011<\/p>\n<p>Email address of sender.<\/p>\n<p>\u3010Password\u3011<\/p>\n<p>Email password of sender.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Sender Information\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Name\u3011<\/p>\n<p>Set the name of the sender.<\/p>\n<p>\u3010Email Address\u3011<\/p>\n<p>Set the sender\u2019s email address to send the email.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Error\u3011<\/p>\n<\/td>\n<td>\n<p>Set whether to display the result of sending email on the HMI or PLC register, error code show as below. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Error Code<\/p>\n<\/td>\n<td>\n<p>Meaning<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Successfully send.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Failed to connect to sever.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Failed to log in<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>Failed to send email.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Reset the Register to Zero Before Sending Mails\u3011<\/p>\n<p>Check whether to reset the register to 0 before sending mails.<\/p>\n<p>\u3010Error Message\u3011<\/p>\n<p>Set the register to display error message from SMTP server with and the data type is\u3010ASCII\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Contact List\u3011<\/p>\n<\/td>\n<td>\n<p>Set the recipients\u2019s email address and groups, there are two pagings, includes\u3010Contacts\u3011and\u3010Groups\u3011. <\/p>\n<p>\u3010Contacts\u3011paging shown as below, each meaning of the options are as follow:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-012.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Options<\/p>\n<\/td>\n<td>\n<p>Function<\/p>\n<\/td>\n<td>\n<p>Icon<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Add<\/p>\n<\/td>\n<td>\n<p>Add new contacts.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-013.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Delete<\/p>\n<\/td>\n<td>\n<p>Delete the selected contacts.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-014.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Edit<\/p>\n<\/td>\n<td>\n<p>Edit the selected contacts.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-015.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Move up<\/p>\n<\/td>\n<td>\n<p>Move up the selected contacts.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-016.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Move down<\/p>\n<\/td>\n<td>\n<p>Move down the selected contacts.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-017.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Import<\/p>\n<\/td>\n<td>\n<p>Import contacts from outside, there are\u3010Default Format\u3011or\u3010Outlook\u3011two ways to import CSV file, figure as shown below.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-018.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Export<\/p>\n<\/td>\n<td>\n<p>Export the contact list as a FATEK style CSV file.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-019.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The\u3010Groups\u3011tab page as shown below, the meaning of each setting option is as follows:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-020.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Options<\/p>\n<\/td>\n<td>\n<p>Function<\/p>\n<\/td>\n<td>\n<p>Icon<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Add<\/p>\n<\/td>\n<td>\n<p>Add Contact Group.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-021.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Delete<\/p>\n<\/td>\n<td>\n<p>Delete the selected contact group.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-022.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Edit<\/p>\n<\/td>\n<td>\n<p>Edit the selected contact group.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-023.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Copy<\/p>\n<\/td>\n<td>\n<p>Copy contact group.<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-024.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Note : the SMTP function of sending email will only send to the specified group. For example, group 1 has A recipient, group 2 has B and C recipients, when sending email to group 2, B and C will receive the same mail. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Check SMTP Setting\u3011<\/p>\n<\/td>\n<td>\n<p>Check whether SMTP is setting correct or not, press\u3010Check SMTP Setting\u3011button, will show up the window and select the group.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-025.png\" \/><\/p>\n<p>If success will show up the window below<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t183_5.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-026.jpg\" \/><\/p>\n<p>And the group will receive a SMTP testing email from FvDesigner.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.3.2 \u3010SMTP\u3011setting example<\/h4>\n<p>We will use the following steps to explain how to set the\u3010SMTP\u3011function and test whether SMTP is correct, here we use gmail to explain.<\/p>\n<p>Step1 : Fill in all all the blanks.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-027.png\" \/><\/p>\n<p>Figure 74 SMTP setting window<\/p>\n<p>Step 2 : Click \u3010Contact List and enter\u3011 \u3010Contacts\u3011 and \u3010Groups\u3011.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-028.jpg\" \/> <\/p>\n<p>Figure 75 SMTP sender information setting window<\/p>\n<p>Step 3 : Click \u3010Check SMTP setting\u3011, select the group you want to test, and if the test is successful, a message will show Send Successful.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-029.png\" \/><\/p>\n<p>Figure 76 SMTP test successfully window<\/p>\n<h3>4.4 \u30104G\u3011<\/h3>\n<p>Can plug 4G Dongle on HMI for wireless Internet access<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-030.png\" \/><\/p>\n<p>Figure 77\u30104G\u3011setting page<\/p>\n<p>Table 34\u30104G\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Basic\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Pin\u3011<\/p>\n<p>The pin code needs to be set up in the mobile phone or computer first, and the data type is\u3010ASCII\u3011, which occupies 6 words<\/p>\n<p>\u3010Signal status\u3011<\/p>\n<p>Display signal strength. The data type is\u3010INT\u3011, the range is 0~5<\/p>\n<p>\u3010Network status\u3011<\/p>\n<p>Show whether the network is connected or not, the data type is\u3010INT\u3011, the range is 0~1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010User\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>This function is only useful when using Huawei&#8217;s dongle, and using other cards will not affect it.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Result\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Send Result\u3011<\/p>\n<p>Display the SMS transmission result (can be set in the alarm), the data type is\u3010INT\u3011, -1 failure\/1 success<\/p>\n<p>\u3010Reset the Register to Zero Before SMS\u3011<\/p>\n<p>Check whether to reset this address before sending SMS<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>HMI can use 4G sim card for wireless Internet access, please notice that the HMI firmware version: 1.5.32 \/ OS version: OS 2.0.4 and above are only supported<\/p>\n<p>No special settings are required to use the 4G network card to access the Internet. Just plug in the 4G Dongle before powering on the HMI. <\/p>\n<p>HMI can use 4G sim card for wireless Internet access, please notice that the HMI firmware version: 1.6.69 and above are only supported<\/p>\n<h3>4.5 \u3010FTP Client\u3011<\/h3>\n<h4>4.5.1 \u3010FTP Client\u3011setting<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-031.png\" \/><\/p>\n<p>Figure 78\u3010FTP Client\u3011setting page<\/p>\n<p>Table 35\u3010FTP Client\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Server List\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Mask Passwords\u3011<\/p>\n<p>Set whether to show the password or not<\/p>\n<p>\u3010ID\u3011<\/p>\n<p>Set the server ID<\/p>\n<p>\u3010Name\u3011<\/p>\n<p>Set the server\u2019s name<\/p>\n<p>\u3010Host\u3011<\/p>\n<p>Set the sever\u2019s IP<\/p>\n<p>\u3010Port\u3011<\/p>\n<p>Set the server\u2019s port.<\/p>\n<p>\u3010User\u3011<\/p>\n<p>Set the login name of the connection server<\/p>\n<p>\u3010Password\u3011<\/p>\n<p>Set the login password of the connection server<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Task List\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Type\u3011<\/p>\n<p>Display the task type<\/p>\n<p>\u3010Comment\u3011<\/p>\n<p>Display the comment of the task<\/p>\n<p>\u3010Trigger\u3011<\/p>\n<p>Display the triggered address<\/p>\n<p>\u3010Connect Server\u3011<\/p>\n<p>Display the connecting server of the task<\/p>\n<p>\u3010Number of Files\u3011<\/p>\n<p>Display the number of the transfer files.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.5.2 \u3010FTP Client\u3011Task setting<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-032.png\" \/><\/p>\n<p>Figure 79\u3010FTP Client\u3011task list setting page<\/p>\n<p>Table 36\u3010FTP Client\u3011task list properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Basic\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Comment\u3011<\/p>\n<p>Comment for this task<\/p>\n<p>\u3010Select Server\u3011<\/p>\n<p>Select the server to connect<\/p>\n<p>\u3010Task\u3011<\/p>\n<p>Select the task, provides\u3010Download to HMI\u3011and\u3010Upload to Server\u3011<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Control\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Trigger Address\u3011<\/p>\n<p>Set the trigger address to execute the task<\/p>\n<p>\u3010Send Result\u3011<\/p>\n<p>Display the result of the excuting task, the data type is\u3010INT\u3011, success: 1 \/ failed: -1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010HMI\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the location for uploading or downloading from the HMI. The following example: To use the data log folder as FTP<\/p>\n<ol>\n<li>select\u3010Internal\u3011<\/li>\n<li>Fill in the location \/datalog\/Group_1 (Note: \/internal does not need to be filled, because\u3010Internal\u3011has been selected)<\/li>\n<\/ol>\n<p>If you don\u2019t know the internal location of the HMI, you can use\u3010File Transfer\u3011to connect and copy.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-033.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remote\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the data access location of the connection server. If it is not filled in, the root directory of the server will be used by default.<\/p>\n<p>\u3010Static\u3011<\/p>\n<p>Read the settings of the server itself, you can fill in the path in the field below<\/p>\n<p>\u3010Dynamic\u3011<\/p>\n<p>The data type is\u3010ASCII\u3011, you can fill in the path in the set register, for example: \/HMI_Datalog<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Download Files\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the number of access files for this task, the upper limit is 99<\/p>\n<p>\u3010Static\u3011<\/p>\n<p>Enter the full name of the file (including the extension filename)<\/p>\n<p>\u3010Dynamic\u3011<\/p>\n<p>The data type is\u3010ASCII\u3011, you can fill in the path in the set register, for example: DataLog.csv<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>4.5.3 Example \u2013 Upload the data log to PC<\/h4>\n<p>The following is an example of using the FTP client function to upload DataLog to the PC.<\/p>\n<p>(This is an example. To use the upload data log, refer to\u3010Upload to remote\u3011in chapter 0-<\/p>\n<p>\u3010Export Data\u3011which will be easier)<\/p>\n<ol>\n<li>Set the connected server, please note that all parameters except the name must be the same as the server to be connected<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-034.png\" \/><\/p>\n<p>Figure 80 Set the server<\/p>\n<ol>\n<li>When setting up data log, please note that we are uploading files, so we must enable the export data function.<\/li>\n<\/ol>\n<p>The location of storage is internal storage, and the name of the exported file is fixed as DataLog.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-035.png\" \/><\/p>\n<p>Figure 81 Data Log setting<\/p>\n<ol>\n<li>Set the task item, the example is uploading to the PC, the task should select upload to server, the location of data log and storage is set to internal storage, so check internal and fill in the path of the data log group in the field.<\/li>\n<\/ol>\n<p>The file name must be the same as the exported file name<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-036.png\" \/><\/p>\n<p>Figure 82 Ftp Setting<\/p>\n<ol>\n<li>Download the project to the HMI, trigger the task after exporting the file.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-037.png\" \/><\/p>\n<p>Figure 83 HMI execution screen<\/p>\n<ol>\n<li>After uploading, you can see the file on the PC. Please note that the FTP Server must be enabled on the computer, otherwise the above operations will not take effect.<\/li>\n<\/ol>\n<p>For the FTP Server tool, there are many tools on the Internet, please check by yourself.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-038.png\" \/><\/p>\n<p>Figure 84 PC get the file<\/p>\n<h3>4.6 \u3010Wi-Fi\u3011<\/h3>\n<p>Wi-Fi Dongle can be plugged into the HMI for wireless Internet access.<\/p>\n<p>Note: This is to enable the address control Wi-Fi function. Even if enable is not checked, the HMI can still plug in the Wi-Fi Dongle for wireless Internet access.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-039.png\" \/><\/p>\n<p>Figure 85\u3010Wi-Fi\u3011setting page<\/p>\n<p>Table 37\u3010Wi-Fi\u3011properties setting page<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable\/Disable Wi-Fi by Register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set a bit to control to enable or disable the Wi-Fi function<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connect Status\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Each status as the table, data type is\u3010INT\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Status<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-2<\/p>\n<\/td>\n<td>\n<p>Wi-Fi module is not enabled<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-1<\/p>\n<\/td>\n<td>\n<p> No dongle is decteced<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Connected<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Unconnect<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Get IP failed.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Access Point Signal\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Each status as the table, data type is\u3010INT\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Status<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Unusable<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Not Good<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>OK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>Very Good<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5<\/p>\n<\/td>\n<td>\n<p>Amazing<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connect Access Point by Register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the access point number through the register, the data type is\u3010INT\u3011.<\/p>\n<p>\u3010Setting\u3011: Access point can be set in advance.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-04\/p5hmi-fvd-en-04-040.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connected SSID Name\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set an address to display the name of the connected wireless network.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Please refer to ch 24.2.3.4-\u3010Wi-Fi\u3011for more details.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This chapter will introduce the various server function [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3346","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3346"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3346\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3346"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3346"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}