{"id":3351,"date":"2026-11-17T18:42:48","date_gmt":"2026-11-17T10:42:48","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-09\/"},"modified":"2026-11-17T18:42:48","modified_gmt":"2026-11-17T10:42:48","slug":"p5hmi-fvd-en-09","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-09\/","title":{"rendered":"Chapter 9 Recipe"},"content":{"rendered":"<p>In practical applications, settings with similar properties or behaviors but have different data contents for parameters are frequently used on equipment for manufacturing processes or actions; the collection of these parameter contents is called Recipe. Excellent recipe management helps increase engineering or production efficiencies.<\/p>\n<h3>9.1 Recipe Data Flow<\/h3>\n<p>Before we start explaining the data flow of recipes on HMI, we must first understand what recipe group files, recipe groups and recipes are.<\/p>\n<p><strong>Recipe<\/strong><\/p>\n<p>For instance, if a machine is able to produce bread and cakes, and their ingredients are both flour, eggs, butter and chocolate, the ingredients can be viewed as the parameters of the machine. However, because the ratio of ingredients for making bread is different from making cakes, the ingredient ratios of the two can be made into two sets of parameters: one for making bread and one for making cakes. The two sets of parameters described above are two different recipes; and every recipe will have a unique number.<\/p>\n<p><strong>Recipe Group<\/strong><\/p>\n<p>A group of recipes that have the same parameters is called a Recipe Group; take the example above for instance, the two recipes (bread and cake) can form a Recipe Group. The recipe function allows users to edit multiple recipe groups, and every recipe group will have a unique Recipe Group ID. All the recipes in the recipe group will have a unique number starting from 0. (For example, the number of bread is 0 and the number of cake is 1)<\/p>\n<p><strong>Recipe Group File<\/strong><\/p>\n<p>There is the common format csv file which the user can use text editors on their own computers or the Recipe Editor in the recipe function to edit the csv file. A recipe group file saves all the data of a recipe group, including all the parameter names and parameter values in the recipe.<\/p>\n<p><strong>Recipe Data Flow<\/strong><\/p>\n<p>When projects are executing on the HMI, all of the parameter data are saved in the recipe group file first, and the user can use the function switch object to import the file into the HMI. Complete parameter contents can be seen if the project has the recipe table object.<\/p>\n<p>There is a buffer in the HMI used to save the data of the current recipe; which recipe to save in this buffer is determined by the Control Address of Recipe No., and the Control Address of Recipe No. is set in the recipe function. Please note that no matter what the Recipe No. currently is, once the import file function is used, the Recipe No. will be reset to 0.<\/p>\n<p>The export function can be used to export the recipe group of the HMI into the recipe group file if the user changed the parameter data of the recipe group, and the contents in the original recipe group file will be overwritten. <\/p>\n<p>The function switch object can be used to write the contents of the current recipe of the HMI to the target address (usually the PLC controller), and it can write the data of the target address into the current recipe of the HMI.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-001.png\" \/><\/p>\n<p>Figure 141 Recipe Data Flow<\/p>\n<p>The recipe function can be found by clicking\u3010Recipe\u3011in the\u3010Functions\u3011window of\u3010Project Explorer\u3011located on the left side, to enter\u3010Recipe Group List\u3011.<\/p>\n<p><strong>Note: Each model of HMI has a different maximum number of recipes. For example, the P5 series has a maximum of 20.<\/strong><\/p>\n<p>The\u3010Add\u3011or\u3010Delete\u3011button on the right can be clicked to add a new recipe group or delete the selected recipe group; items in the recipe group list can also be double-clicked to edit the selected recipe group. On the left side of every recipe group in the recipe group list has a unique ID. This is called the recipe group ID.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-002.png\" \/><\/p>\n<p>Figure 142 Recipe Settings Screen<\/p>\n<p>\u3010Recipe\u3011in the\u3010Insert\u3011tab function group of the Ribbon workspace can also be clicked to add a new recipe group directly and enter the\u3010Recipe Group Properties\u3011editing page. The new recipe group will be added after pressing the\u3010OK\u3011button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-003.png\" \/><\/p>\n<p>Figure 143 Insert Recipe Screen<\/p>\n<p>The following are detailed explanations of the\u3010Recipe Group Properties\u3011.<\/p>\n<h3>9.2 Recipe Group Properties<\/h3>\n<h4>9.2.1 \u3010General\u3011<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-004.png\" \/><\/p>\n<p>Figure 144\u3010General\u3011Screen of\u3010Recipe\u3011<\/p>\n<p>Table 63\u3010General\u3011Properties of\u3010Recipe\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Basic\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Group Name\u3011<\/p>\n<p>The name of the recipe group.<\/p>\n<p>\u3010Comment\u3011<\/p>\n<p>Comment describing this recipe group.<\/p>\n<p>\u3010Memory Block\u3011<\/p>\n<p>The number of the buffer area of this recipe group, the number of each recipe group is different.<\/p>\n<p>\u3010Backup Memory\u3011<\/p>\n<p>Select to save the recipe data of the HMI into the backup memory of the HMI when the power to the HMI is interrupted in order to avoid loss of data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Group File\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010No. of Recipe Parameters\u3011<\/p>\n<p>Set the number of parameters for this recipe group.<\/p>\n<p>\u3010No. of Recipe\u3011<\/p>\n<p>Set the number of recipes for this recipe group. <\/p>\n<p><strong>Note: The memory size of every recipe group cannot exceed 6291456 words, which means that (the total number of words for every parameter) x (the number of recipes) \u2266 6291456. If the user is uncertain whether the limit has been exceeded, the user can move the mouse cursor onto the text and a tooltip will tell the user how many words are currently used.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-005.png\" \/><\/p>\n<p>\u3010Open Recipe Editor\u3011<\/p>\n<p>The recipe editor will appear, allowing the user to add a new recipe group file when this button is pressed or edit a recipe group file saved on the PC storage.<\/p>\n<p><strong>Note: When using the recipe editor to modify an existing file, if the parameter name is not same as the original, a warning window will pop up to ask whether to overwrite.<\/strong><\/p>\n<p><strong>When you use the function of simulation, the recipe group file will be put in the path: C:\\Users\\UserAccount\\Documents\\Fatek\\FvDesigner\\run\\storage\\internal\\recipe<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Name\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Recipe Name\u3011<\/p>\n<p>Check whether to enable the recipe name function.<\/p>\n<p>\u3010Type\u3011<\/p>\n<p>Set the type of recipe name to Ascii, Unicode, Big5 or GB18030.<\/p>\n<p>\u3010Length\u3011<\/p>\n<p>Set the length of recipe.<\/p>\n<p>\u3010Use Current Recipe Name Address\u3011<\/p>\n<p>When this option is selected, you can specify the memory address used for the recipe name. It can be set to an internal register or a PLC address. The amount of memory used will vary depending on the length of the name.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Internal Recipe Memory\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Recipe Data\u3011<\/p>\n<p>Display the address range used by the recipe group data in the internal memory area of the HMI<\/p>\n<p>\u3010Memory Required\u3011<\/p>\n<p>Display the number of words occupied by the recipe group data<\/p>\n<p>\u3010Recipe Set Name\u3011<\/p>\n<p>Display the address range used by the recipe name in the internal memory area of the HMI<\/p>\n<p>\u3010Current Recipe Data\u3011<\/p>\n<p>Display the address range of the current recipe data in the internal memory area of the HMI<\/p>\n<p>\u3010User-defined Current Recipe Address\u3011<\/p>\n<p>If you select the option to define the current recipe data address, the user can decide which address the buffer memory should start from<\/p>\n<p><strong>Note: This address can only use the internal register<\/strong><\/p>\n<p>\u3010Auto Access Target Address\u3011<\/p>\n<p>If you check this option, when the current recipe data is changed, the data will be automatically written into the \u3010target address\u3011<\/p>\n<p>\u3010Current Recipe Index\u3011<\/p>\n<p>The register data of this address is a 16-bit UINT. This integer is used to represent the number of the current recipe. The recipe used by the recipe group when the HMI is executing is the current recipe.<\/p>\n<p>\u3010User-defined Current Recipe Address of Recipe No.\u3011<\/p>\n<p>User can decide the current recipe number control address by himself, instead of using the recipe register configured by the system default<\/p>\n<p><strong>Note: The recipe number control address cannot be the same as the current recipe start address<\/strong><\/p>\n<p>\u3010Power-On Reset Recipe No.\u3011<\/p>\n<p>This option becomes available after enabling Custom Recipe Number.<\/p>\n<p>If the system default address is used, the value will not be retained regardless of whether Backup Memory is checked. To retain the recipe number address, you must change it to a non-volatile memory address (such as $U:XNV or $U:XNVA) or an external device address.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>9.2.2 \u3010Parameter\u3011<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-006.jpg\" \/><\/p>\n<p>Figure 145\u3010Parameter\u3011\u3010Recipe\u3011settings<\/p>\n<p>Table 64\u3010Parameter\u3011\u3010Recipe\u3011properties settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Field<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Parameter Config\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Target Address Type\u3011<\/p>\n<p>\u3010Continuous\u3011<\/p>\n<p>The target(usually PLC) address can only be set for the first parameter of in the table below. The addresses of the other parameters will be filled in consecutively in memory and the user cannot modify them. <\/p>\n<p>\u3010Random\u3011<\/p>\n<p>The user can set the target address for every parameter, but the addresses must be unique. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-007.png\" \/><\/p>\n<p>\u3010Add\u3011<\/p>\n<p>Add a new item at the bottom of the parameter table<\/p>\n<p>\u3010Delete\u3011<\/p>\n<p>Delete the selected parameter, if not selected, delete the last one<\/p>\n<p>\u3010Insert\u3011<\/p>\n<p>Add one under the selected parameter<\/p>\n<p>\u3010Copy\u3011<\/p>\n<p>Copy the selected parameter<\/p>\n<p>\u3010Paste\u3011<\/p>\n<p>Paste the copied parameter<\/p>\n<p>If is select a row, the parameter name and other parameters except the current recipe address will be overwritten.<\/p>\n<p>If is not select a row, the copied parameters will be pasted in the last row.<\/p>\n<p>\u3010Import\u3011<\/p>\n<p>Import the recipe parameter file. The content has a fixed format. Be sure to export the file first and then modify the file then import.<\/p>\n<p>When importing, it will check for validity, and if there is an error, a warning will pop up.<\/p>\n<p>\u3010Export\u3011<\/p>\n<p>To export the recipe parameter file, it should be noted that only the content in the red box can be changed.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-008.png\" \/><\/p>\n<p>The following are the explanations for parameter settings. <\/p>\n<p>\u3010Parameter Name\u3011<\/p>\n<p>The parameter name cannot be blank and each parameter should have a unique name. It can be entered directly or selected by\u3010Font\u3011.<\/p>\n<p>\u3010Data Type\u3011<\/p>\n<p>Available selections include 16Bit-BCD, 16Bit-INT, 16Bit-UINT, 16Bit-HEX, 32Bit-BCD, 32Bit-INT, 32Bit-UINT, 32Bit-FLOAT, 32Bit-HEX, 64Bit-BCD, 64Bit-INT, 64Bit-UINT, 64Bit-FLOAT, 64Bit-HEX, Ascii-String, Uniucode (Simplified Chinese), Uniucode (Traditional Chinese), Unucode (Others).<\/p>\n<p>\u3010Current Recipe Address\u3011<\/p>\n<p>The current recipe address of the parameter is determined by the start address set by the user. The user cannot change it.<\/p>\n<p>\u3010Words\u3011<\/p>\n<p>If the data type is 16 bits, it will occupy 1 word, and if the data is 32 bits, it will occupy 2 words. If the data type is Ascii-String or Uniucode, the user can decide how many characters this parameter occupies, and each word occupy 2 bytes.<\/p>\n<p>Each Ascii-String occupy 2 words.<\/p>\n<p>Each Unicode occupy 1 word.<\/p>\n<p>\u3010Target Address\u3011<\/p>\n<p>Set the address of the target register (usually PLC).<\/p>\n<p>\u3010Digit Places\u3011<\/p>\n<p>Set the position of the decimal.<\/p>\n<p>\u3010Scope Control\u3011<\/p>\n<p>Allows the user to set a value range for this parameter. If not selected, the default value range of the parameter will be the range set by the\u3010From\u3011and\u3010To\u3011columns.<\/p>\n<p>\u3010From\u3011<\/p>\n<p>Set the minimum value of this parameter; this value cannot be less than the absolute minimum value for the data type. The default value for this field is the absolute minimum value.<\/p>\n<p>\u3010To\u3011<\/p>\n<p>Set the maximum value of this parameter; this value cannot be greater than the absolute maximum value for the data type. The default value for this field is the absolute maximum value.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>9.2.3 \u3010Advanced\u3011<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-009.png\" \/><\/p>\n<p>Figure 146\u3010Advanced\u3011\u3010Recipe\u3011Settings<\/p>\n<p>Table 65\u3010Advanced\u3011General Settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Field<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Use Control Words\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Use the control word to control the recipes actions. Including; reading, or writing data from\/to the PLC, editing, and other functions. <\/p>\n<p>\u3010Control Address\u3011<\/p>\n<p>Set the control address to a specific address that will trigger the function<\/p>\n<p>\u3010Reset Control Address After Finish\u3011<\/p>\n<p>After the control address is triggered, it must be reset to zero to do the next function control. You can manually set the value or check this option to automate the reset.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>#<\/p>\n<\/td>\n<td>\n<p>Controls the value of the address (Hex)<\/p>\n<\/td>\n<td>\n<p>Features<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>0010h<\/p>\n<\/td>\n<td>\n<p>The recipe data is transferred to the HMI<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>0011h<\/p>\n<\/td>\n<td>\n<p>MicroSD card recipe data is transferred to the HMI<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>0012h<\/p>\n<\/td>\n<td>\n<p>USB port recipe data is transferred to the HMI<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>0020h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data is stored in the interface<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5<\/p>\n<\/td>\n<td>\n<p>0021h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data is stored in the MicroSD card<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6<\/p>\n<\/td>\n<td>\n<p>0022h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data is stored in a USB storage device<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7<\/p>\n<\/td>\n<td>\n<p>0040h<\/p>\n<\/td>\n<td>\n<p>The HMI recipe data is transferred to the target address (Usually the PLC address)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8<\/p>\n<\/td>\n<td>\n<p>0080h<\/p>\n<\/td>\n<td>\n<p>The recipe data of the target address (Usually the PLC address) is transferred to the HMI<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>9<\/p>\n<\/td>\n<td>\n<p>0100h<\/p>\n<\/td>\n<td>\n<p>Add a set of recipes to the specified recipe group, such as the current group 3 recipe. When this signal is triggered, a new set of recipes will be added and the new group will be group 3. The former group 3 will become group 4.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10<\/p>\n<\/td>\n<td>\n<p>0101h<\/p>\n<\/td>\n<td>\n<p>Add a set of recipes under the specified recipe group, such as group 3. When the signal is triggered, a new set of recipes is added. In this case, the recipe group is 4.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>11<\/p>\n<\/td>\n<td>\n<p>0102h<\/p>\n<\/td>\n<td>\n<p>Copies a set of specified recipes on a specified recipe group, such as group 3. When the signal is triggered, the recipe of group 3 will be copied to a set of recipes and will become the new group 3. The former group 3 will become group 4.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>12<\/p>\n<\/td>\n<td>\n<p>0103h<\/p>\n<\/td>\n<td>\n<p>Copies a specific set of recipies under the recipie group, such as a recipe currently in group 3. When the signal is triggered, replicates group 3\u2019s recipes with a set of recipes from group 4. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>13<\/p>\n<\/td>\n<td>\n<p>0104h<\/p>\n<\/td>\n<td>\n<p>Deletes the current recipe group<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>14<\/p>\n<\/td>\n<td>\n<p>0200h<\/p>\n<\/td>\n<td>\n<p>Read the parameter data from the source address then write to the recipe group storage space, this function transfers the entire recipe group data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15<\/p>\n<\/td>\n<td>\n<p>0400h<\/p>\n<\/td>\n<td>\n<p>Write the parameter data of the recipe storage space to the source address, this function transfers the entire recipe group data.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010File Name\u3011<\/p>\n<p>Two types of file names,\u3010Static\u3011and\u3010Dynamic\u3011.\u3010Static\u3011allows you to set the recipe below the checkbox.\u3010Dynamic\u3011allows you to set the string length. The maximum amount of characters is 16, the contents of the string affect the file name.<\/p>\n<p><strong>Note: No need to enter &quot;.csv&quot; by yourself.<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Use Status Word\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Use the status word group to monitor the current state of the recipe processing.<\/p>\n<p>\u3010Status Address\u3011<\/p>\n<p>Set the status address to the following to achieve the desired status message, as show in the table below.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>#<\/p>\n<\/td>\n<td>\n<p><strong>Value of the Status Address (Hex)<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Features<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>0000h<\/p>\n<\/td>\n<td>\n<p>Initialize<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>4000h<\/p>\n<\/td>\n<td>\n<p>Busy<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>8000h<\/p>\n<\/td>\n<td>\n<p>Success<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>0100h<\/p>\n<\/td>\n<td>\n<p>Recipe data transfer to HMI has failed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5<\/p>\n<\/td>\n<td>\n<p>0101h<\/p>\n<\/td>\n<td>\n<p>MicroSD card recipe data transfer to HMI has failed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6<\/p>\n<\/td>\n<td>\n<p>0102h<\/p>\n<\/td>\n<td>\n<p>USB recipe data transfer to HMI has failed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7<\/p>\n<\/td>\n<td>\n<p>0200h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data has failed to save<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8<\/p>\n<\/td>\n<td>\n<p>0201h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data has failed to save to the MicroSD card<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>9<\/p>\n<\/td>\n<td>\n<p>0202h<\/p>\n<\/td>\n<td>\n<p>HMI recipe data has failed to save to the USB storage device<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Support Recipe Group Data From\/To Source Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set whether to use the entire recipe group and source address to transfer data.<\/p>\n<p>\u3010Source Address\u3011<\/p>\n<p>Set the source address of the starting address. The software will automatically calculate the total number of addresses used and will prompt the user for the ending address. <\/p>\n<p>\u3010Include Recipe Name\u3011<\/p>\n<p>Set whether to include the recipe name when using the entire recipe group and the source address.<\/p>\n<p>\u3010Length\u3011<\/p>\n<p>Set the recipe name length.<\/p>\n<p>\u3010Do Not Reset The Current Recipe No. When Transfer\u3011<\/p>\n<p>When unchecked, this function will reset the\u3010Control Address of Recipe No.\u3011to zero after transmission.<\/p>\n<p>After checking, the current selection will be kept.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Notification\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set whether to allow the recipe group to enable the notification function.<\/p>\n<p>After enabled, the notification address can be set at the follow, and it will be notified when the function\u3010Write Recipe To PLC\u3011or\u3010Read Recipe From PLC\u3011is executed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Search\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set whether to use the search recipe function. Use this function to search for the current recipe name or the recipe parameter column for a particular ASCII type.<\/p>\n<p>\u3010Search Recipe Name\u3011<\/p>\n<p>Use the search recipe name to search for the recipe. When the\u3010Recipe Name\u3011is not checked in the\u3010General\u3011, it will become\u3010Search With Recipe Parameter\u3011.<\/p>\n<p>\u3010Search with Recipe Parameter(String Type)\u3011<\/p>\n<p>Search for recipe parameters in Ascii or Unicode format<\/p>\n<p>\u3010Search with Recipe(String Type)\u3011<\/p>\n<p>Search for recipe parameters in Ascii or Unicode format<\/p>\n<p>\u3010Search for an exact match\u3011<\/p>\n<p>Search for recipes with the exact same parameters as entered.<\/p>\n<p>\u3010Search Target Address\u3011<\/p>\n<p>Search using text address\u2019 and character length, up to 20 bytes.<\/p>\n<p>\u3010Control Bit\u3011<\/p>\n<p>Search is initialized when the control bit changes from 0 to 1<\/p>\n<p>\u3010Status Address\u3011<\/p>\n<p>Shows the status of the current search. The following is a list of status addresses and results<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>#<\/p>\n<\/td>\n<td>\n<p>The value of the status address (Hex)<\/p>\n<\/td>\n<td>\n<p>Features<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>0000h<\/p>\n<\/td>\n<td>\n<p>Initialize<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>4000h<\/p>\n<\/td>\n<td>\n<p>Busy<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>8000h<\/p>\n<\/td>\n<td>\n<p>Search action is complete<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Result Count Address\u3011<\/p>\n<p>Set the search result count address. After the searching is complete, the number of search results will be stored. If there is no seach, the number stored will be 0<\/p>\n<p>\u3010Result List Address\u3011<\/p>\n<p>Set the search result list address. After the searching is complete, a number that represents the temporary register is stored. The magnitude of the number is the maximum number of searches and the maximum number of recipes that can be set. <\/p>\n<p>\u3010Length\u3011<\/p>\n<p>It is the number of searchable items, and the maximum length can be set as\u3010No. of Recipe\u3011<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>9.2.4 \u3010Recipe File List\u3011<\/h4>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-010.jpg\" \/><\/p>\n<p>Figure 147\u3010Recipe File List\u3011Screen of\u3010Recipe\u3011<\/p>\n<p>Table 66\u3010General\u3011Properties of\u3010Recipe\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Add\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Add an already existing recipe group file to the recipe file list.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Delete\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Delete an item in the recipe file list.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Clear All\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Delete all the items in the recipe file list.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.3 \u3010Recipe Memory\u3011<\/h3>\n<p>The HMI system will allocate a dedicated memory area for each recipe group according to the\u3010Memory Area No.\u3011, so that users can directly access the data in the recipe group through the exclusive [recipe register], including: (n is\u3010Memory Block No.\u3011)<\/p>\n<p>Recipe Data Memory&#8212;&#8212;&#8212;&#8212;&#8212;- $Rn:\uff24<\/p>\n<p>Recipe Name Memory&#8212;&#8212;&#8212;&#8212;&#8212; $Rn:N<\/p>\n<p>Current Recipe Data Memory&#8212;&#8212;- $Rn:C<\/p>\n<p>Current Recipe Name Memory&#8212;&#8211; $Rn:I<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-011.png\" \/><\/p>\n<p>Figure 148 Recipe Memory<\/p>\n<p>After the formula is created, the\u3010Recipe Memory\u3011can be read and written in various functions, such as using\u3010Numeric Input\/Display\u3011to read.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-012.png\" \/><\/p>\n<p>Figure 149 Recipe Memory Usage<\/p>\n<p>Table 67 Recipe Memory<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Recipe Data Memory<\/strong><\/p>\n<p><strong>\u3010$Rn:D\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-013.png\" \/><\/p>\n<p>$Rn:D0~$Rn:Dm-1, n is\u3010Memory Block No.\u3011, m is the No. of words occupied by the recipe group data.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Recipe Name Memory<\/strong><\/p>\n<p><strong>\u3010$Rn:N\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-014.png\" \/><\/p>\n<p>$Rn:N0~$Rn:Nm-1, n is\u3010Memory Block No.\u3011, m is the No. of words occupied by the recipe name.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Current Recipe Data Memory\u3010$Rn:N\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The address range of the current recipe data in the internal memory area in the HMI.<\/p>\n<p>$Rn:C0~$Rn:Cm-1, n is\u3010Memory Block No.\u3011, m is the No. of words occupied by the current recipe.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Current Recipe Name Memory<\/strong><\/p>\n<p><strong>\u3010$Rn:<\/strong> I<strong>\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The current recipe number address that in the address range of the internal memory area of the HMI.<\/p>\n<p>$Rn:I0, n is\u3010Memory Block No.\u3011.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.4 \u3010Recipe Editor\u3011<\/h3>\n<p>This function allows users to add recipe group files or edit existing recipe group files.<\/p>\n<p>You can open this interface in\u3010Open Recipe Editor\u3011in the\u3010Recipe Group Properties\u3011\u3010General\u3011setting function, or click RecipeEditor.exe from the FvDesigner folder to open it.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-015.jpg\" \/><\/p>\n<p>Figure 150 Open\u3010Recipe Editor\u3011from software<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-016.jpg\" \/> <\/p>\n<p>Figure 151 Open\u3010Recipe Editor\u3011from folder<\/p>\n<p>Table 68\u3010Recipe Editor\u3011Functions<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Import Recipe Config\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>It is visible when the editor is opened from the folder, and the recipe file (.rpcfg) exported by the software can be imported for editing.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010New Recipe\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Add a new recipe.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Open Recipe\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Open an existing recipe file (.csv).<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Save Recipe\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Save the currently edited recipe group contents into a recipe group file. The user can select to save it as a csv file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Save Recipe As\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Save the currently edited recipe group contents into a new file; the user can select to save it as a csv file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Exit\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Exit the recipe editor.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010No. of Recipe Parameters\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The \u201cNo. of Recipe Parameters\u201d cannot be set if the user is adding a recipe group file. The No. of Recipe Parameters can be set if the user is modifying an existing file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010No. of Recipe\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Determine how many recipes this recipe group file has. A number will be automatically generated on the left side of the recipe.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Add to Recipe File List\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Open the editor from software and the option can be seen. If checked, this file will be automatically added to the recipe file list after finishing editing.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>Note:<\/strong><\/p>\n<p><strong>Please note that when the user is editing the value of the parameters, this value cannot exceed the limit between the minimum and maximum value of this parameter, in which the data type of the parameter usually defines the maximum\/minimum value. However, the value set for the\u3010Scope Control\u3011will be referred to if the user selects\u3010Scope Control\u3011in parameter settings.<\/strong><\/p>\n<p><strong>If this parameter is an Ascii String, the length of characters entered by the user cannot exceed the length configured for the parameter x2. If the parameter in the file opened by the user exceeded the restricted range, the background will be displayed in red.<\/strong><\/p>\n<h3>9.5 \u3010Recipe Table\u3011<\/h3>\n<p>The\u3010Recipe Table\u3011is used to view or edit the contents of the recipe group. In addition, the user can decide to use a\u3010Sub Switch\u3011in the recipe table. \u3010Sub Switch\u3011allows users to load the data in the recipe group file into the\u3010Recipe Table\u3011or save the parameter contents in the\u3010Recipe Table\u3011into a recipe group file.<\/p>\n<p>The\u3010Recipe Table\u3011object can be found in the\u3010Recipe\u3011category of the\u3010Toolbox\u3011to the right; it can also be found by clicking the<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-017.png\" \/>icon in the\u3010Object\u3011group of the\u3010Design\u3011page on the Ribbon workspace. Please refer to the <strong>Chapter 0\u2013<\/strong><\/p>\n<p><strong>\u3010Recipe<\/strong> Table\u3011for a detailed introduction to the properties of this object; the following is only an introduction to special properties and functions related to recipes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-018.png\" \/><\/p>\n<p>Figure 152\u3010Recipe Table\u3011Property Setting Screen<\/p>\n<p>Table 69\u3010Recipe Table\u3011Functions<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Group\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The recipe group ID and recipe group name can be seen here if the user added a new recipe group in the recipe settings function. The\u3010OK\u3011button can only be pressed after the user has selected a recipe group.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t208_1.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-019.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Table Type\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Only Show Current Recipe\u3011<\/p>\n<p>Display the current recipe according to the Control Address of the Recipe No. in recipe settings. The default value for index is 0.<\/p>\n<p>\u3010Show All\u3011<\/p>\n<p>Show all contents of the recipe group.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Transpose\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Reverse the rows and columns. For example, row 1 in the original table becomes column 1 in the transposed table.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-020.jpg\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-021.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Tap to Change Current Recipe\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>When checked, you can click the recipe header or item to automatically switch the current recipe to the clicked recipe.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Allow Input\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The user will be able to change the parameter contents in the recipe table during execution if this option is selected.<\/p>\n<p>If\u3010Function Switch\u3011or\u3010Sub Switch\u3011in the Toolbox is also used, the user can save the value contents of the recipe table into a recipe group file, or change the parameter of the controller.<\/p>\n<p>\u3010Input Method for Recipe name\u3011<\/p>\n<p>Input methods includes\u3010None\u3011,\u3010Pinyin(Simplified Chinese)\u3011, and\u3010Chewing(Traditional Chinese)\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Advanced\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Use Filter\u3011<\/p>\n<ul>\n<li>Filter Recipe Name: Display the recipe group that is filter  by recipe name.<\/li>\n<li>Filter Recipe Parameters(String Type): Display the recipe group that is filter by recipe parameters.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Sub Switch\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>If the\u3010Save\u3011or\u3010Load\u3011button in the\u3010Sub Switch\u3011page is selected, corresponding buttons will also appear on the top-right of the recipe table editing section screen when the\u3010OK\u3011button is pressed.<\/p>\n<p>\u3010Save\u3011<\/p>\n<p>Once the user clicks this button during execution, the parameter contents of the current\u3010Recipe Table\u3011will be saved onto the recipe group file in recipe settings.<\/p>\n<p>\u3010Load\u3011<\/p>\n<p>Once the user clicks this button during execution, the contents of this file will be loaded into the\u3010Recipe Table\u3011according to the recipe group file in recipe settings.<\/p>\n<p>\u3010Auto Scroll\u3011<\/p>\n<p>When the\u3010Control Address of Recipe No.\u3011has changed, the recipe table will jump to the corresponding recipe.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-022.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.6 \u3010Recipe Selector\u3011<\/h3>\n<p>The\u3010Recipe Selector\u3011is used to select a current recipe. The operator can only see the name of the recipe on the HMI and cannot know the contents of the recipe parameters. Therefore, the parameter data is confidential.<\/p>\n<p>The\u3010Recipe Selector\u3011object can be found in the\u3010Recipe\u3011category of\u3010Toolbox\u3011, it can also be found by clicking the<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-023.png\" \/>icon in the\u3010Object\u3011group of the\u3010Design\u3011page on the Ribbon workspace. Please refer to the <strong>Chapter19.4.31\u2013\u3010Recipe Selector\u3011<\/strong>for detailed introduction to the properties of this object; the following is only introduction to special properties and functions related to recipes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-024.png\" \/><\/p>\n<p>Figure 153\u3010Recipe Selector\u3011Property Setting Screen<\/p>\n<p>Table 70\u3010Recipe Selector\u3011Functions<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Group\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Recipe Group\u3011<\/p>\n<p>The recipe group ID and recipe group name can be seen here if the user added a new recipe group in the recipe settings function. The\u3010OK\u3011button can only be pressed after the user has selected a recipe group.<\/p>\n<p>\u3010Background\u3011\u3010Background Selector\u3011<\/p>\n<p>Set the background color.<\/p>\n<p>\u3010Background\u3011\u3010List Background\u3011<\/p>\n<p>Set the background color of the list.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Advanced\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Source\u3011<\/p>\n<p>Set the recipe selector\u2019s souce<\/p>\n<p>\u3010Recipe Name\u3011<\/p>\n<p>Default value. Use recipe name as recipe selector\u2019s data.<\/p>\n<p>\u3010Recipe Recipe(String Type)\u3011<\/p>\n<p>When the recipe parameter has ASCII String type, you can use the ASCII String type parameter as the data displayed of the recipe selector.<\/p>\n<p>\u3010Sort\u3011<\/p>\n<p>Set whether the recipe selector data is displayed in text order.<\/p>\n<p>\u3010Use Filter\u3011<\/p>\n<p>Use filter in dynamic mode, filter the needed options in the recipe selector by specifying the value or text of the\u3010Filter String Address\u3011, for example, the\u3010Filter String Address\u3011is R50, and R50=A, the recipe selector only the recipe group name with &quot;A&quot; text will be displayed<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.7 \u3010Function Switch\u3011<\/h3>\n<p>There are a few functions in the\u3010Function Switch\u3011component related to recipes; users can select these functions according to their needs. Please refer to the following table for detailed introductions to these functions.<\/p>\n<p>The\u3010Function Switch\u3011object can be found in the\u3010Lamp\/Switch\u3011category of the\u3010Toolbox\u3011to the right. Please refer to the <strong>Chapter19.4.2.4-<\/strong>\u3010Function Switch\u3011for detailed introduction to the properties of this object. The following is only introduction to special properties and functions related to recipes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-025.png\" \/><\/p>\n<p>Figure 154\u3010Function Switch\u3011Property Setting Screen<\/p>\n<p>Table 71\u3010Function Switch\u3011Recipe Functions<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Function\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Recipe: Import Recipe Group from File\u3011<\/p>\n<p>Import the contents of the recipe group file. If a recipe table exists, the user will be able to see complete recipe group contents. If the register addresses of some displayed objects are the same as the current recipe address in the recipe settings, users will also be able to see the value changes of the displayed objects. A drop-down list will appear once this function is used; the user must decide which recipe group to use for this function switch.<\/p>\n<p><strong>Note: The current recipe of this recipe group will be set to Recipe No. 0 when this function is used.<\/strong><\/p>\n<p>\u3010Recipe: Export Recipe Group back to File\u3011<\/p>\n<p>Export the contents of the recipe group into a recipe group file. The user can choose to export a new file or overwrite the original recipe group file. A drop-down list will appear once this function is used; the user must decide which recipe group to use for this function switch.<\/p>\n<p>\u3010Recipe: Write Current Recipe to Target Address\u3011<\/p>\n<p>A drop-down list will appear once this function is used; the user must decide which recipe group to use for this function switch. The parameter value of the current recipe of the HMI will be written to the register of the target address according to the setting of this recipe group.<\/p>\n<p>\u3010Recipe: Read from Target Address to Current Recipe\u3011<\/p>\n<p>A drop-down list will appear once this function is used; the user must decide which recipe group to use for this function switch. The register contents of the target address will be read and the value will be written to the current recipe of the HMI according to the setting of this recipe group.<\/p>\n<p>\u3010Recipe: Add Default Recipe\u3011<\/p>\n<p>Add a set of recipes to or above the current recipe and switch the current recipe to the most recent recipe<\/p>\n<p>\u3010Recipe: Copy Current Recipe\u3011<\/p>\n<p>Copy the the current recipe and put it above or below the recipe you copied.<\/p>\n<p>\u3010Recipe: Delete Current Recipe\u3011<\/p>\n<p>Delete the current recipe and switch the deleted recipe group with the next recipe group. <\/p>\n<p>\u3010Recipe: Transfer Source Address to Recipe Group\u3011<\/p>\n<p>The source address parameter data is written to the recipe group. The source address can be set in the advanced tab of the recipe. The function  the entire recipe group data.<\/p>\n<p>\u3010Recipe: Transfer Recipe Group to Source Address\u3011<\/p>\n<p>The parameters of the recipe group are read and written to the source address. The source address can be set in the advanced tab of the recipe. The entire recipe group data is transferred.<\/p>\n<p>\u3010Recipe: Import Recipe group from File, then Transfer to Source Address\u3011<\/p>\n<p>After importing the contents of the recipe group file into the group storage space, the parameter data of the recipe group is read and written to the source address. The source address can be set in the advanced tab of the recipe. This function transfers the entire recipe group data.<\/p>\n<p>\u3010Recipe: Transfer Source Address to Recipe Group, then Export to File\u3011<\/p>\n<p>After the source address data is read, it is written to the recipe group. The contents of the recipe group are exported to the file. The source address can be set in the advanced tab of the recipe. This function sends the entire recipe group data.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-026.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Recipe Group\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the corresponding recipe group for this function switch.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>9.8 Example<\/h3>\n<p>The following example can allow the users to better understand how to use the recipe functions and components related to recipes.<\/p>\n<ol>\n<li>Adding a new recipe group in the recipe settings function. This recipe group uses 4 parameters and 3 recipes; please refer to the following figure for details on the settings:<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-027.png\" \/><\/p>\n<p>Figure 155 Recipe Settings Example 1<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-028.png\" \/><\/p>\n<p>Figure 156 Recipe Settings Example 2<\/p>\n<ol>\n<li>Press the\u3010Open Recipe Editor\u3011function and the\u3010Recipe Editor\u3011will appear on the screen; the parameter contents inside will be the same as the recipe settings, including the maximum and minimum value that the user will be able to input. Refer to the following figure for editing contents, and remember to save the file when editing is completed; please remember to check\u3010Add to Recipe File List\u3011.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-029.jpg\" \/><\/p>\n<p>Figure 157\u3010Recipe Editor\u3011Example<\/p>\n<ol>\n<li>Pull two\u3010Recipe Table\u3011from\u3010Toolbox\u3011to the editing section of the screen, and select (ID 0) MyRecipe0 for\u3010Recipe Group\u3011. Please select\u3010Only Show Current Recipe\u3011for one of the recipe tables and\u3010Show All\u3011and\u3010Allow Input\u3011for the other recipe table.<\/li>\n<li>Pull a\u3010Recipe Selector\u3011from\u3010Toolbox\u3011to the editing section of the screen, and select (ID 0) MyRecipe0 for recipe group.<\/li>\n<li>Pull four\u3010Function Switch\u3011from\u3010Toolbox\u3011to the editing section of the screen, and select (ID 0) MyRecipe0 for recipe group. The functions of these four switches are\u3010Recipe: Import Recipe Group from File\u3011, \u3010Recipe: Export Recipe Group back to File\u3011,\u3010Recipe: Write Current Recipe to Target Address\u3011and\u3010Recipe: Read from Target Address to Current Recipe\u3011respectively. In order to avoid confusion, the text: Import, Export, 2PLC and 2HMI can be added to respective function switches.<\/li>\n<li>Pull 6\u3010Numeric Input\/Display\u3011and 2\u3010Text Input\/Display\u3011from\u3010Toolbox\u3011to the editing section of the screen. The\u3010Monitor Address\u3011of these 8 objects corresponds to the\u3010Current Recipe Address\u3011and\u3010Target Address\u3011in recipe settings. The\u3010Data Type\u3011of the\u3010Numeric Input\/Display\u3011object is also the same as the\u3010Data Type\u3011of the parameter. Set the maximum value and minimum value of these objects to provide a reasonable range.<\/li>\n<li>Pull a\u3010Numeric Input\/Display\u3011from\u3010Toolbox\u3011to the editing section of the screen. The\u3010Monitor Address\u3011of this object is the same as the\u3010Control Address of Recipe No.\u3011in recipe settings. Please also select\u3010Allow Input\u3011.\u3010Max.\u3011is 2.\u3010Min.\u3011is 0 (because there are only 3 recipes, therefore the values used is 0~2).<\/li>\n<li>Drag 9\u3010Numeric Input\/Display\u3011and 6\u3010Text Input\/Display\u3011from the \u3010Toolbox\u3011to the workspace. The\u3010Monitor Address\u3011of these 15 objects correspond to the\u3010Recipe Data Address\u3011and\u3010Recipe Name Address\u3011of the\u3010Recipe Memory Area\u3011. The\u3010Data Type\u3011of the \u3010Numeric Input\/Display\u3011object should also be consistent with the \u3010Data Type\u3011of the parameter. Please also set the maximum and minimum values of these objects within a reasonable range.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-030.png\" \/><\/p>\n<p>Figure 158 Example Screen<\/p>\n<ol>\n<li>We can use the\u3010Simulation\u3011function once the project is created to simulate the behavior of this project in the HMI on the computer. Click\u3010Simulation\u3011in the\u3010Project\u3011function tab of the Ribbon. It will ask the user to build the project first before executing the function. The starting simulation screen is as shown below:<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-031.png\" \/><\/p>\n<p>Figure 159 Simulation Screen 1<\/p>\n<ol>\n<li>Click the import function switch; this operation will read the contents of the recipe group file into the HMI, including the current recipe and recipe table. If the monitored addresses of the displayed objects are the same as the current recipe address of the recipe settings, the displayed numeric value or text will changes accordingly. The contents of the recipe selector will also change accordingly. The current recipe will be reset to Recipe No. 0 every time a file is imported, so the contents of the recipe selector will be the Juice1 with a number of 0. During this time the screen will be displayed as follows:<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-032.png\" \/><\/p>\n<p>Figure 160 Simulation Screen 2<\/p>\n<ol>\n<li>Change the numeric input of the Control Address of Recipe No. 2 and the current recipe will change to Juice 3.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-033.png\" \/><\/p>\n<p>Figure 161 Simulation Screen 3<\/p>\n<ol>\n<li>Click on the 2PLC function switch; this operation will write the data contents of the current recipe into the register of the target address (usually the controller). It can be observed that the displayed objects in the target area are also the parameter data of Juice 3 after clicking the switch. <\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-034.png\" \/><\/p>\n<p>Figure 162 Simulation Screen 4<\/p>\n<ol>\n<li>A keypad will appear allowing the user to input a numeric value once the apple field in the recipe table below is clicked. Enter 400 and press OK. It can be observed that the displayed objects for the recipe table and current recipe also changes to 400.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-035.png\" \/><\/p>\n<p>Figure 163 Simulation Screen 5<\/p>\n<ol>\n<li>Click the Export function switch; this operation will export the parameter contents of this recipe group in the HMI onto the original file. Because we changed the apple parameter data of Juice 3, the recipe group file will also save the changed data.<\/li>\n<li>Click the 2HMI function switch; this operation will write the contents of the target register back into the current recipe of the HMI. At this time, it can be observed that the value of the apple parameters of Juice 3 for the current recipe and recipe table changes back to 300.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-036.png\" \/><\/p>\n<p>Figure 164 Simulation Screen 6<\/p>\n<ol>\n<li>Click the Import function switch and it can be observed that the apple parameter of Juice 3 changes to 400 again. This is because we used the export function before, so the contents of the file have also been changed. However, because the file was imported again, the number of the current recipe was reset to Recipe No. 0, so the current recipe will show the data of Juice1.<\/li>\n<\/ol>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-09\/p5hmi-fvd-en-09-037.png\" \/><\/p>\n<p>Figure 165 Simulation Screen 7<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In practical applications, settings with similar proper [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3351","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3351"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3351\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3351"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3351"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}