{"id":3353,"date":"2026-11-17T18:42:50","date_gmt":"2026-11-17T10:42:50","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-11\/"},"modified":"2026-11-17T18:42:50","modified_gmt":"2026-11-17T10:42:50","slug":"p5hmi-fvd-en-11","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-11\/","title":{"rendered":"Chapter 11 Schedule"},"content":{"rendered":"<p>The\u3010Schedule\u3011function can be used if users want the HMI to automatically execute specific actions regularly over long periods of time while the HMI is operating; the\u3010Schedule\u3011function can automatically execute the action selected by the user according to the date and time.<\/p>\n<p>This chapter will explain the Schedule related screens and usage methods.<\/p>\n<h3>11.1 Schedule List<\/h3>\n<p>Click on\u3010Schedule\u3011in the\u3010Project Explorer\u3011of the FvDesigner and the\u3010Schedule List\u3011will appear; current\u3010Schedules\u3011that were already set will be displayed on the list in order according to the\u3010Group ID\u3011set for each schedule.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-11\/p5hmi-fvd-en-11-001.jpg\" \/><\/p>\n<p>Figure 169\u3010Schedule\u3011List Screen<\/p>\n<p>To set a new set of schedule, click on the\u3010Add\u3011button on the right and a\u3010Schedule\u3011settings dialog will appear for the user to operate.<\/p>\n<p>To edit a\u3010Schedule\u3011that was already set, double-click on the\u3010Schedule\u3011entry on the list or first select the\u3010Schedule\u3011entry and then click on the\u3010Edit\u3011button on the right; at this time the settings dialog for this\u3010Schedule\u3011entry will appear for the user to modify.<\/p>\n<p>To delete a \u3010Schedule\u3011 that was already set, select the \u3010Schedule\u3011entry and click on the\u3010Delete\u3011button on the right to delete this\u3010Schedule\u3011entry.<\/p>\n<h3>11.2 Schedule Settings<\/h3>\n<p>The setting screen of the\u3010Schedule\u3011function is as shown in the figure below, the meanings of each setting option are listed below:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-11\/p5hmi-fvd-en-11-002.png\" \/><\/p>\n<p>Figure 170\u3010Schedule\u3011Setting Screen<\/p>\n<p>Table 75\u3010Schedule\u3011Setting Properties<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Group ID\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the Group ID of the\u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the comments of the\u3010Schedule\u3011. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mode\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the execution action behavior of the\u3010Schedule\u3011.<\/p>\n<p>\u3010Action Mode\u3011<\/p>\n<p>The available actions that can be configured include: \u3010Set Bit\u3011, \u3010Reset Bit\u3011, \u3010Write Word\u3011, and \u3010Run Script\u3011.<\/p>\n<p>\u3010Action Address\u3011<\/p>\n<p>Set the address to be operated when the schedule is executed. This option is not available when the mode is set to \u3010Run Script\u3011.<\/p>\n<p>\u3010Power-ON Start\/End Action\u3011<\/p>\n<p>Set whether to detect the schedule configuration upon startup. This feature can only be enabled after selecting \u3010Enable End Action\u3011.<\/p>\n<p>If the HMI startup time falls within the start and end time, the start action will be executed.<br \/>If the HMI startup time is outside the start and end time, the end action will be executed.<\/p>\n<p>\u3010Start\/End Action\u3011<\/p>\n<p>Set the parameters to be configured when the system time reaches the \u3010Start Time\u3011or\u3010End Time\u3011.<\/p>\n<p>\u3010Enable End Action\u3011<\/p>\n<p>Set to enable end action. The\u3010End Value\u3011,\u3010End Script\u3011and\u3010End Time\u3011of the\u3010Schedule\u3011can be set when this option is enabled; when the system time reaches the set\u3010End Time\u3011, the HMI will automatically execute the end action set.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Date\/Time Set\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the date and time for the\u3010Schedule\u3011to execute the action.<\/p>\n<p>\u3010Type &#8211; Constant &#8211; Individual Day\u3011<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-11\/p5hmi-fvd-en-11-003.png\" \/><\/p>\n<p>When \u3010Individual Day\u3011is selected, the schedule will be configured based on the day of the week.<br \/>If \u3010Enable End Action\u3011is checked, you can also set the end date and time.<\/p>\n<p>\u3010Type &#8211; Constant &#8211; Specific Day\u3011<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-11\/p5hmi-fvd-en-11-004.png\" \/><\/p>\n<p>When \u3010Specific Day\u3011is selected, the schedule can be configured to execute at a specific date and time.<br \/>If \u3010Enable End Action\u3011is checked, you can set the end time.<\/p>\n<p>\u3010Type &#8211; Address\u3011<\/p>\n<p>When \u3010Address\u3011is selected, a total of 11 consecutive registers will be used for configuration.<br \/>The data type used for each register is \u301016Bit-UINT\u3011.<br \/>The meaning of the values stored in each register is described in the table below:<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Schedule Update<\/p>\n<\/td>\n<td>\n<p>When this address is set to 0, the schedule will be disabled.<br \/>When set to 1, the HMI will read the configuration and enable the schedule.<\/p>\n<p>If you need to update the schedule settings while the system is running, set this address to 0, then back to 1.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Update Result<\/p>\n<\/td>\n<td>\n<p>When the \u3010Schedule Update\u3011address is set to 1, the HMI will read the configuration and show the result at this address:<\/p>\n<ul>\n<li><strong>1<\/strong> = Read successful<\/li>\n<li><strong>2<\/strong> = Read failed<\/li>\n<li><strong>3<\/strong> = Invalid date or time configuration<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Action Mode<\/p>\n<\/td>\n<td>\n<p>When bit 0 of this address is set to 1, the \u3010End Action\u3011 will be enabled.<br \/>When bit 1 is set to 1, the \u3010Individual Day\u3011mode will be enabled.<br \/>When bit 2 is set to 1, the \u3010Specific Date\u3011mode will be enabled.<br \/>When bit 3 is set to 1, the \u3010Startup Action\u3011 will be enabled.<\/p>\n<p>Note: To use the \u3010Startup Action\u3011, users must also enable bit 0 \u3010End Action\u3011 .Otherwise, the \u3010Startup Action\u3011 will not be executed.<\/p>\n<p>If both bit 1 and bit 2 are set to 1, the operating mode will default to \u3010Individual Day\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Start Time(Day)<\/p>\n<\/td>\n<td>\n<p>Start Date Setting for the \u3010Schedule\u3011:<\/p>\n<ul>\n<li>If \u3010Individual Day\u3011mode is selected:<br \/>Values 1\u20137 correspond to Monday through Sunday.<\/li>\n<li>If \u3010Specific Date\u3011 mode is selected:<br \/>Values 1\u201312 correspond to January through December.<br \/>Value 13 represents Every Month.<\/li>\n<li>If neither \u3010Individual Day\u3011 nor \u3010Specific Date\u3011  is selected:<br \/>Bits 0\u20136 correspond to Monday through<strong> <\/strong>Sunday.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Start Time(Hour)<\/p>\n<\/td>\n<td>\n<p>Set the hour part of the \u3010Schedule\u3011 start time.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Start Time(Min.)<\/p>\n<\/td>\n<td>\n<p>Set the minute part of the \u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Start Time(Sec.)<\/p>\n<\/td>\n<td>\n<p>Set the second part of the \u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>End Time(Day)<\/p>\n<\/td>\n<td>\n<p>End Date Setting for the Schedule Execution:<\/p>\n<ul>\n<li>If \u3010Individual Day\u3011mode is selected:<br \/>Values 1\u20137 correspond to Monday through<strong> <\/strong>Sunday.<\/li>\n<li>If \u3010Specific Date\u3011mode is selected:<br \/>Values 1\u201331 correspond to the 1st through 31st<strong> <\/strong>day of the month.<\/li>\n<li>If neither \u3010Individual Day\u3011nor \u3010Specific Date\u3011 is selected:<br \/>This address will not be<strong> <\/strong>read.<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>End Time(Hour)<\/p>\n<\/td>\n<td>\n<p>Set the hour part of the \u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>End Time(Min.)<\/p>\n<\/td>\n<td>\n<p>Set the minute part of the \u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>End Time(Sec.)<\/p>\n<\/td>\n<td>\n<p>Set the second part of the \u3010Schedule\u3011.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3><\/h3>\n<h3>11.3 Examples<\/h3>\n<p>Example 1: Execute start action at fixed times weekly.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Address<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Value<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Function<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Start reading the\u3010Time Setting Address\u3011, and changes the\u3010Schedule\u3011settings according to the value read.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p><strong>\u3010Time Setting Address\u3011+2<\/strong><\/p>\n<\/td>\n<td>\n<p>Bit 0: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable end action. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 1: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable\u3010Individual Day\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 2: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable\u3010Specific Day\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\">\n<p><strong>\u3010Time Setting Address\u3011+3<\/strong><\/p>\n<\/td>\n<td>\n<p>Bit 0: 0<\/p>\n<\/td>\n<td>\n<p>Set not to execute\u3010Schedule\u3011on Monday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 1: 1<\/p>\n<\/td>\n<td>\n<p>Set to execute\u3010Schedule\u3011on Tuesday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 2: 0<\/p>\n<\/td>\n<td>\n<p>Set not to execute\u3010Schedule\u3011on Wednesday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 3: 1<\/p>\n<\/td>\n<td>\n<p>Set to execute\u3010Schedule\u3011on Thursday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 4: 1<\/p>\n<\/td>\n<td>\n<p>Set to execute\u3010Schedule\u3011on Friday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 5: 0<\/p>\n<\/td>\n<td>\n<p>Set not to execute\u3010Schedule\u3011on Saturday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 6: 0<\/p>\n<\/td>\n<td>\n<p>Set not to execute\u3010Schedule\u3011on Sunday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+4<\/strong><\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<td>\n<p>Set the hour of the Start Time for the\u3010Schedule\u3011to start execution as 8 A.M.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+5<\/strong><\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>Set the minute of the Start Time for the\u3010Schedule\u3011to start execution as 30 minutes.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+6<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Set the second of the Start Time for the\u3010Schedule\u3011to start execution as 0 seconds.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Example 2: Individually setting the date and time to execute start action and end action weekly.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Address<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Value<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Function<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Start reading the\u3010Time Setting Address\u3011, and changes the\u3010Schedule\u3011settings according to the value read.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p><strong>\u3010Time Setting Address\u3011+2<\/strong><\/p>\n<\/td>\n<td>\n<p>Bit 0: 1<\/p>\n<\/td>\n<td>\n<p>Enable End Action.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 1: 1<\/p>\n<\/td>\n<td>\n<p>Enable\u3010Individual Day\u3011; The end day and start day can be set individually.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 2: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable\u3010Specific Day\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+3<\/strong><\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Set the start day for the\u3010Schedule\u3011to start execution as Monday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+4<\/strong><\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<td>\n<p>Set the hour of the Start Time for the \u3010Schedule\u3011to start execution as 8 A.M.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+5<\/strong><\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>Set the minute of the Start Time for the \u3010Schedule\u3011to start execution as 30 minutes.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+6<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Set the second of the Start Time for the \u3010Schedule\u3011to start execution as 0 seconds.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+7<\/strong><\/p>\n<\/td>\n<td>\n<p>7<\/p>\n<\/td>\n<td>\n<p>Set the end day for the \u3010Schedule\u3011to end execution as Sunday.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+8<\/strong><\/p>\n<\/td>\n<td>\n<p>17<\/p>\n<\/td>\n<td>\n<p>Set the hour of the End Time for the\u3010Schedule\u3011to end execution as 5 P.M.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+9<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Set the minute of the End Time for the\u3010Schedule\u3011to end execution as 0 minutes.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+10<\/strong><\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>Set the second of the End Time for the\u3010Schedule\u3011to end execution as 30 seconds.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Example 3: Execute start action on specific day and time.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Address<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Value<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Function<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Start reading the\u3010Time Setting Address\u3011, and changes the\u3010Schedule\u3011settings according to the value read.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p><strong>\u3010Time Setting Address\u3011+2<\/strong><\/p>\n<\/td>\n<td>\n<p>Bit 0: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable end action. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 1: 0<\/p>\n<\/td>\n<td>\n<p>Do not enable\u3010Individual Day\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Bit 2: 1<\/p>\n<\/td>\n<td>\n<p>Enable\u3010Specific Day\u3011. <\/p>\n<p>\u3010Time Setting Address\u3011+3 and\u3010Time Setting Address\u3011+7 will save the start month and start day settings respectively.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+3<\/strong><\/p>\n<\/td>\n<td>\n<p>6<\/p>\n<\/td>\n<td>\n<p>Set the start month as June.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+4<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Set the hour of the Start Time for the\u3010Schedule\u3011to start execution as 0 A.M.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+5<\/strong><\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>Set the minute of the Start Time for the\u3010Schedule\u3011to start execution as 30 minutes.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+6<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Set the second of the Start Time for the\u3010Schedule\u3011to start execution as 0 seconds.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Setting Address\u3011+7<\/strong><\/p>\n<\/td>\n<td>\n<p>30<\/p>\n<\/td>\n<td>\n<p>Set the start day as the 30<sup>th<\/sup>.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The\u3010Schedule\u3011function can be used if users want the HMI [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3353","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3353","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3353"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3353\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3353"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3353"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3353"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}