{"id":3354,"date":"2026-11-17T18:42:50","date_gmt":"2026-11-17T10:42:50","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-12\/"},"modified":"2026-11-17T18:42:50","modified_gmt":"2026-11-17T10:42:50","slug":"p5hmi-fvd-en-12","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-12\/","title":{"rendered":"Chapter 12 Data Transfer"},"content":{"rendered":"<p>The\u3010Data Transfer\u3011function can be used if the user wants the HMI to execute data transfer actions under specific conditions while the HMI is operating; the\u3010Data Transfer\u3011function will execute a data transfer according to the conditions set by the user. There a two modes of data transfer:\u3010Data to Data\u3011and\u3010CSV File to Data\u3011.<\/p>\n<p>This chapter will explain\u3010Data Transfer\u3011related pages and settings.<\/p>\n<h3>12.1 Data Transfer List (Data to Data Mode)<\/h3>\n<p>Click on\u3010Data Transfer\u3011in\u3010Project Explorer\u3011of the FvDesigner and the\u3010Data Transfer List\u3011will appear;\u3010Data Transfer\u3011that are currently set will be displayed on the list in the order of the\u3010Group ID\u3011set for them.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-12\/p5hmi-fvd-en-12-001.jpg\" \/><\/p>\n<p>Figure 171\u3010Data Transfer\u3011List Screen<\/p>\n<p>To set a new Data Transfer, click on the\u3010Add\u3011button on the right, and the\u3010Data Transfer\u3011setting dialog will appear for the user to operate.<\/p>\n<p>To edit a\u3010Data Transfer\u3011that was already set, double-click on the\u3010Data Transfer\u3011entry or first select the\u3010Data Transfer\u3011entry and then click on the\u3010Edit\u3011button on the right. The settings dialog of this\u3010Data Transfer\u3011entry will appear for the user to modify.<\/p>\n<p>To delete an existing\u3010Data Transfer\u3011, select the\u3010Data Transfer\u3011entry and then click on the\u3010Delete\u3011button on the right to delete this\u3010Data Transfer\u3011entry.<\/p>\n<p>If you need to set a new data transfer, similar to the original, you can select the original\u3010Data Transfer\u3011and click the\u3010Copy\u3011button on the right side of the window. <\/p>\n<h3>12.2 Data Transfer Settings (Data to Data Mode)<\/h3>\n<p>The settings screen of the\u3010Data Transfer\u3011is as shown in the figure below and the meanings of each setting are listed below:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-12\/p5hmi-fvd-en-12-002.png\" \/><\/p>\n<p>Figure 172 Setting Dialog of\u3010Data Transfer\u3011<\/p>\n<p>Table 76 Setting Properties of\u3010Data Transfer\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Group ID\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the group ID of the\u3010Data Transfer\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the comment of the\u3010Data Transfer\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the behavior of the\u3010Data Transfer\u3011.<\/p>\n<p>\u3010Data Type\u3011<\/p>\n<p>Set the data type of the\u3010Data Transfer\u3011.<\/p>\n<p>\u3010No. of Bits\u3011<\/p>\n<p>Set the number of bits per transfer; it can be set between1~65535 bits. The more number of bits per transfer, the longer it will take for the transfer to be completed. Therefore, make sure that there is sufficient time for the data transfer to be completed every time it is executed.<\/p>\n<p>\u3010No. of Words\u3011<\/p>\n<p>Set the number of words per transfer; it can be set between 1~65535 words. The more number of words per transfer, the longer it will take for the transfer to be completed. Therefore, make sure there is sufficient time for data transfer to be completed every time it is executed.<\/p>\n<p>\u3010Execution Condition\u3011<\/p>\n<p>Set the condition to execute\u3010Data Transfer\u3011. The\u3010Trigger Bit\u3011and\u3010Trigger Condition\u3011can be set below if the execution condition is set as\u3010Triggered by Bit\u3011; The data transfer will be executed when the status changes satisfy the conditions set. The\u3010Time Interval\u3011can be set below if the execution condition is set as\u3010Time-based\u3011; The HMI will execute the data transfer according to the set time interval.<\/p>\n<p>\u3010Source Address\u3011<\/p>\n<p>Set the source address for executing the\u3010Data Transfer\u3011; The HMI will read the No. of Bits or No. of Words set from the source address and write them into the\u3010Destination Address\u3011when the data transfer is executed.<\/p>\n<p>\u3010Destination Address\u3011<\/p>\n<p>Set the destination address for executing the\u3010Data Transfer\u3011; The HMI will read the No. of Bits or No. of Words set from the source address and write them into the\u3010Destination Address\u3011when the data transfer is executed.<\/p>\n<p>\u3010Notification Bit\u3011<\/p>\n<p>Specify a bit to set or reset upon the completion of the data transfer. This bit can be used to trigger other functions to run on the transferred data.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>12.3 Data Transfer List (CSV to Data Mode)<\/h3>\n<p>Click on \u3010Data Transfer\u3011in\u3010Project Explorer\u3011 and the\u3010Data Transfer List\u3011 will appear. Switch to the \u3010CSV File to Data\u3011 tab. \u3010Data Transfer\u3011that are currently set will be displayed on the list in the order of the\u3010Group ID\u3011set for them.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-12\/p5hmi-fvd-en-12-003.jpg\" \/><\/p>\n<p>Figure 173 CSV Data Transfer List Screen<\/p>\n<p>To set a new Data Transfer, click on the\u3010Add\u3011button on the right, and the\u3010Data Transfer\u3011setting dialog will appear for the user to operate.<\/p>\n<p>To edit a\u3010Data Transfer\u3011that was already set, double-click on the\u3010Data Transfer\u3011entry or first select the\u3010Data Transfer\u3011entry and then click on the\u3010Edit\u3011button on the right. The settings dialog of this\u3010Data Transfer\u3011entry will appear for the user to modify.<\/p>\n<p>To delete an existing \u3010Data Transfer\u3011, select the\u3010Data Transfer\u3011entry and then click on the\u3010Delete\u3011button on the right to delete this\u3010Data Transfer\u3011entry.<\/p>\n<p>If you need to create a new\u3010Data Transfer\u3011and set it similar to the original, select the original\u3010Data Transfer\u3011and click the\u3010Copy\u3011button on the right side of the window.<\/p>\n<h3>12.4 Data Transfer Settings (CSV to Data Mode)<\/h3>\n<p>The\u3010CSV to Data Transfer Mode\u3011settings are below. The meanings of each setting are listed below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-12\/p5hmi-fvd-en-12-004.png\" \/><\/p>\n<p>Figure 174\u3010CSV to Data Transfer Mode\u3011Settings Screen<\/p>\n<p>Table 77\u3010CSV to Data Transfer Mode\u3011Setting Properties <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Group ID\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the group ID of the\u3010Data Transfer\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the comment of the\u3010Data Transfer\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010CSV File Path\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the source of the\u3010Data Transfer\u3011.<\/p>\n<p>\u3010File Source\u3011<\/p>\n<p>Set the location of the CSV file source:\u3010internal\u3011,\u3010microSD Card\u3011, or\u3010USB Storage\u3011.<\/p>\n<p>\u3010File Name\u3011<\/p>\n<p>Enter the file name of the CSV file. If\u3010Dynamic Name\u3011is selected, the name of the file can be saved to a specified location. This allows the program to change CSV files by saving a new name into the specified location. The register address and length can be set. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010CSV File Content\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Delimiter\u3011<\/p>\n<p>Set the delimiter between entries.<\/p>\n<p>\u3010CSV Data\u3011<\/p>\n<p>Set the start and end positions in the CSV file. Enter a\u3010From\u3011column and row and an\u3010To\u3011column row. The direction the data is read can be changed by clicking the\u3010Direction\u3011icon.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Data Type\u3011<\/p>\n<p>Select the data type of the\u3010CSV to Data File Transfer\u3011.<\/p>\n<p>\u3010Trigger Bit\u3011<\/p>\n<p>Set the address of the bit that triggers the\u3010CSV to Data File Transfer\u3011.<\/p>\n<p>\u3010Trigger Condition\u3011<\/p>\n<p>Select the type of bit change that provides the trigger: OFF to ON, ON to OFF, or both directions.<\/p>\n<p>\u3010Destination Address\u3011<\/p>\n<p>Set the target address of the\u3010CSV to Data File Transfer\u3011.<\/p>\n<p>\u3010Result State Address\u3011<\/p>\n<p>The\u3010CSV to Data File Transfer\u3011result status is stored in this location.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Result<\/p>\n<\/td>\n<td>\n<p>Explanation<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Transfer Success<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Source file open file failed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>There are too few entries in the source<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>The source is unrecognized<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Notification Bit\u3011<\/p>\n<p>Notify a bit upon the completion of the\u3010Data Transfer\u3011. <\/p>\n<p>Level: Set the bit as 0 or 1.<\/p>\n<p>Pulse: Set the bit to 1 and automatically restore to 0 after continuing the time set by\u3010Width\u3011.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The\u3010Data Transfer\u3011function can be used if the user want [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3354","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3354","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3354"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3354\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3354"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3354"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3354"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}