{"id":3358,"date":"2026-11-17T18:42:53","date_gmt":"2026-11-17T10:42:53","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-16\/"},"modified":"2026-11-17T18:42:53","modified_gmt":"2026-11-17T10:42:53","slug":"p5hmi-fvd-en-16","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-16\/","title":{"rendered":"Chapter 16 OPC UA"},"content":{"rendered":"<p>OPC UA (OPC Unified Architecture) is a communication standard designed for industrial automation. The characteristic advantage is cross-platform, unified communication standardization, suitable for the communication environment of a variety of machines and equipment, and can meet the needs of data exchange and remote monitoring.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-001.png\" \/><\/p>\n<p>Figure 194 OPC UA Application architecture diagram<\/p>\n<p>The main features of the FATEK\u3010OPC UA Server\u3011include\uff1a<\/p>\n<ul>\n<li>Simple and fast establishment of OPC UA server data structure<\/li>\n<li>Support for folder structures, enabling grouping and classification of related data<\/li>\n<li>Remote browsing and access support<\/li>\n<li>Read and write functionality, enabling access to PLC register data<\/li>\n<li>Real-time display of server connection status on the execution screen<\/li>\n<\/ul>\n<h3>16.1 OPC UA Server<\/h3>\n<h4>16.1.1 Setting<\/h4>\n<h5>16.1.1.1 Server<\/h5>\n<p>When selecting the product series as \u3010FvRT(PC)\u3011or \u3010OPC UA(PC)\u3011, you can access the settings page for the OPC UA server by clicking on \u3010OPC UA Server\u3011in the \u3010Function\u3011window of the \u3010Project Explorer\u3011panel on the left, the\u3010Server\u3011tab can be used to set the the basic connection information and security verification mechanism of the OPC UA Server, as shown below:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-002.png\" \/><\/p>\n<p>Figure 195\u3010OPC UA Server\u3011\u3010Server\u3011setting page<\/p>\n<p>Table 99\u3010OPC UA Server\u3011\u3010Server\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Enable OPC UA Server\u3011<\/p>\n<\/td>\n<td>\n<p>Check whether to enable\u3010OPC UA Server\u3011, this is the main switch of\u3010OPC UA Server\u3011function. The detailed fields can be set only after it is enabled, and the related \u3010Tag\u3011and\u3010Address\u3011tabs will appear.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Basic\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Server Name\u3011<\/p>\n<p>Set the name of the server, which can be used as a description<\/p>\n<p>\u3010Endpoint URL\u3011<\/p>\n<p>The server address will be automatically set to the IP of the host (PC or HMI). This field is only for display and cannot be changed manually<\/p>\n<p>\u3010Port\u3011<\/p>\n<p>Set the server port. Default is 55000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Security\u3011<\/p>\n<\/td>\n<td>\n<p>Security protection and encryption method can be set.<\/p>\n<p>\u3010Security Policy\u3011<\/p>\n<p>You can specify the method of security protection, you can choose &quot;None&quot; or one of the following:<\/p>\n<ul>\n<li>Basic128Rsa15<\/li>\n<li>Basic256<\/li>\n<li>Basic256Sha256<\/li>\n<\/ul>\n<p>\u3010Message Security Mode\u3011<\/p>\n<p>You can specify the encryption mode, select &quot;None&quot; or one of the following:<\/p>\n<ul>\n<li>Sign<\/li>\n<li>Sign &amp; Encrypt<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Authentication\u3011<\/p>\n<\/td>\n<td>\n<p>Set the authentication method.<\/p>\n<p>\u3010Anonymous\u3011<\/p>\n<p>No authentication required<\/p>\n<p>\u3010Username\/Password\u3011<\/p>\n<p>Enter the username and password for authentication<\/p>\n<p>\u3010Certificate\u3011<\/p>\n<p>Import the certificate file and private key, and enter the corresponding private key password.<\/p>\n<p>After the password is entered, it will be mask.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>16.1.1.2 Tag<\/h5>\n<p>Check\u3010Enable OPC UA Server\u3011to see this page, in which you can create tags and their corresponding addresses.<\/p>\n<p>Click the\u3010Add Group\u3011button on the right to add a new group, click the\u3010Add Tag\u3011button to add a new tag, the group and the tag are in a tree structure: a group can be created underneath Added new groups and tags. Click the\u3010Delete\u3011button to delete the selected group or taf. Double-click the item to directly edit the field settings of the selected group or tag.<\/p>\n<p>The OPC UA server specification supports the Embedded UA Server Profile 1.03 of the OPC Foundation.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-003.png\" \/><\/p>\n<p>Figure 196\u3010OPC UA Server\u3011\u3010Tag\u3011setting page<\/p>\n<p>Table 100\u3010OPC UA Server\u3011\u3010Tag\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Group\u3011<\/p>\n<\/td>\n<td>\n<p>Each group can directly set the fields as follows<\/p>\n<p>\u3010Name\u3011<\/p>\n<p>Click on the name to directly enter and modify.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Search Name\u3011<\/p>\n<\/td>\n<td>\n<p>You can search by group or tag name, but it must be an exact match to navigate directly.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Tag\u3011<\/p>\n<\/td>\n<td>\n<p>Each tag can directly set the fields as follows.<\/p>\n<p>\u3010Name\u3011<\/p>\n<p>Click on the name to directly enter and modify.<\/p>\n<p>\u3010Data Type\u3011<\/p>\n<p>There are\u3010Bit\u3011,\u301016Bit-INT\u3011,\u301016Bit-UINT\u3011,\u301032Bit-INT\u3011,\u301032Bit-UINT\u3011,\u301032Bit-FLOAT\u3011, \u3010ASCII\u3011can be selected.<\/p>\n<p>\u3010Address\u3011<\/p>\n<p>According to the data type, the user can set the address corresponding to each tag<\/p>\n<p>\u3010Length\u3011<\/p>\n<p>If the data type is 16-bit, it will occupy 1 word, and 32-bit will occupy 2 words; if it is Ascii-String, the user can decide how many words the tag occupies. Each word group can contain 2 bytes.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Add Group\u3011<\/p>\n<\/td>\n<td>\n<p>Click on the group or tag on the left to add a new group in that directory.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Add Tag\u3011<\/p>\n<\/td>\n<td>\n<p>Click on the group or tag on the left to add a new tag in that directory.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Add Groups\u3011<\/p>\n<\/td>\n<td>\n<p>Click on the group or tag on the left to add multiple groups in that directory.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Add Tags\u3011<\/p>\n<\/td>\n<td>\n<p>Click on the group or tag on the left to add multiple tags in that directory.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Delete\u3011<\/p>\n<\/td>\n<td>\n<p>Delete the selected group or tag.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Delete Al\u3011<\/p>\n<\/td>\n<td>\n<p>Delete all tags.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Import\u3011<\/p>\n<\/td>\n<td>\n<p>Import tag files from *.csv.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Export\u3011<\/p>\n<\/td>\n<td>\n<p>Export the current tags as a *.csv file.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Import Help\u3011<\/p>\n<\/td>\n<td>\n<p>Documentation for importing tags.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010OPC UA Server\u3011 supports OPC Foundation&#8217;s Embedded UA Server Profile 1.03.<\/p>\n<p>In the \u3010Enable OPC UA Client\u3011, register tags can be found in the &quot;Objects\/Tags&quot; folder. Other tags contain default server information, as shown in the image below:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-004.png\" \/><\/p>\n<p>Figure 197 Reading Information with OPC UA Client<\/p>\n<h5>16.1.1.3 Address<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-005.png\" \/><\/p>\n<p>Figure 198\u3010OPC UA Server\u3011\u3010Address\u3011setting page<\/p>\n<p>Table 101\u3010OPC UA Server\u3011\u3010Address\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Status Address\u3011<\/p>\n<\/td>\n<td>\n<p>Use the status address to monitor the running status of the OPC UA server<\/p>\n<p>\u3010Connection\u3011<\/p>\n<p>Set the status address of the OPC UA server. The following is the state definition table.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value (16Bit-INT)<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>Disable<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Stopped<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Running<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>-1<\/p>\n<\/td>\n<td>\n<p>Error<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Control Address\u3011<\/p>\n<\/td>\n<td>\n<p>Use the control address to control the operation of the OPC UA server in real time<\/p>\n<p>\u3010Connection\u3011<\/p>\n<p>Set the control address of the OPC UA server. The following is the state definition table.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Value (16Bit-INT)<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>None<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1<\/p>\n<\/td>\n<td>\n<p>Stop<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>Start<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>16.1.2 Server setting steps<\/h4>\n<h5>16.1.2.1 Adding a new project<\/h5>\n<p>To create a new project in FvDesigner, click \u3010New\u3011on the left side of the project window. Choose either \u3010FvRT(PC)\u3011or \u3010OPC UA(PC)\u3011,then click \u3010Finish\u3011to create the project.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-006.png\" \/><\/p>\n<p>Figure 199 Choose product series of the project<\/p>\n<h5>16.1.2.2 Setting up PLC Connection<\/h5>\n<p>In the \u3010System\u3011window of the \u3010Project Explorer\u3011 panel on the left, click \u3010Link\u3011to enter the link setup page. This page allows you to configure the PLC device that OPC UA will access. If \u3010OPC UA(PC)\u3011is selected as the project model, only FATEK PLCs can be used.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-007.jpg\" \/><\/p>\n<p>Figure 200 Choose external device connection<\/p>\n<h5>16.1.2.3 Setting up Server and Tags<\/h5>\n<p>On the left-hand side of the screen, in the \u3010Functions\u3011window under \u3010Project Explorer\u3011, click on \u3010OPC UA Server\u3011. Check the box for \u3010Enable OPC UA Server\u3011to configure the server. (The default port for the OPC UA server is 55000, but it can be changed as needed.)<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-008.png\" \/><\/p>\n<p>Figure 201 Enable OPC UA Server<\/p>\n<p>On the \u3010Tags\u3011page, you can create tags to access PLC register data. The steps are as follows : click the \u3010Add Tag\u3011button to create a new tag, then click on the \u3010Address\u3011of that tag to input the linked PLC register address. In the settings page, you can create multiple \u3010Group\u3011and \u3010Tags\u3011according to your own needs to establish a categorized data structure.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-009.png\" \/><\/p>\n<p>Figure 202 Set OPC UA Tags<\/p>\n<h5>16.1.2.4 Compilation and Simulation<\/h5>\n<p>After configuring the OPC UA server and tags, click \u3010Compile\u3011to generate a .cfrp file upon successful compilation. The compilation result will display the location where the project is stored and information about the applicable dongle model. After compilation, click \u3010Simulation\u3011to perform functional testing. Once testing is successful, use \u3010FvRT.exe\u3011to run the project.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-010.jpg\" \/><\/p>\n<p>Figure 203 Compile project<\/p>\n<h5>16.1.2.5 Running the OPC UA Server<\/h5>\n<p>Insert \u3010IGU-FvRT\u3011or \u3010IGU-OPC UA\u3011into the computer, open the \u3010FvRT\u3011software, click &quot;Open Project,&quot; select the compiled project (.cfrp), and then click the \u3010Run\u3011button to start running the OPC UA server. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-011.png\" \/><\/p>\n<p>Figure 204 Choose project to run<\/p>\n<p>If the project model is &quot;OPCUA,&quot; the server running status and connection count information will be displayed.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-012.png\" \/><\/p>\n<p>Figure 205 OPC UA Server running screen<\/p>\n<h3>16.2 OPC UA Client<\/h3>\n<p>For the OPC UA client function,go to\u3010Project Explorer\u3011-&gt;\u3010System\u3011-&gt;\u3010Link\u3011, and add a link property in\u3010PLC Device\u3011:<\/p>\n<p>\u3010Interface Type\u3011select\u3010Direct Link (Ethernet)\u3011,<\/p>\n<p>\u3010Manufacturer\u3011select\u3010OPC UA\u3011<\/p>\n<p>\u3010Product Series\u3011select\u3010OPC UA Client\u3011,then can set OPC UA Client connection<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-013.png\" \/><\/p>\n<p>Figure 206\u3010OPC UA Client\u3011setting page<\/p>\n<p>The setting method is same as 3.3.1-PLC Device<\/p>\n<h4>16.2.1 Tag<\/h4>\n<p>In the settings tab, click the external tags\u3010Import\u3011button on the below to open the import tag window<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-014.png\" \/><\/p>\n<p>Figure 207\u3010OPC UA Client\u3011\u3010Tag Import\u3011setting page<\/p>\n<p>Table 102\u3010OPC UA Client\u3011\u3010Tag Import\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Source\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Import from device\u3011<\/p>\n<p>Same as the IP address and port set before, which is the connection setting of the OPC UA server.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-015.png\" \/><\/p>\n<p>\u3010Import from file\u3011<\/p>\n<p>Import a CSV file in a specific format and update the tag table directly<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Edit Tags\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Add\u3011<\/p>\n<p>Select a new tag from the OPC UA server to add.<\/p>\n<p>(Note: You need to import tags from the device first and make sure to connect to an OPC UA server before you can add tags directly from the server)<\/p>\n<p>\u3010Delete\u3011<\/p>\n<p>Delete the selected tag<\/p>\n<p>\u3010Export\u3011<\/p>\n<p>Export the current label settings into a CSV file in a specific format, which can be imported and used later<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>16.2.2 Security and Authentication<\/h4>\n<p> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-016.png\" \/><\/p>\n<p>Figure 208\u3010OPC UA Client\u3011\u3010Security and Authentication\u3011setting page<\/p>\n<p>Table 103\u3010OPC UA Client\u3011\u3010Security and Authentication\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Server\u3011<\/p>\n<\/td>\n<td>\n<p>\u3010Endpoint URL\u3011<\/p>\n<p>The URL of the OPC UA server will automatically use the\u3010IP Address\u3011and\u3010Port\u3011in the\u3010Interface Setting\u3011\u3010Basic\u3011to form the format &quot;opc.tcp:\/\/IP:port&quot;. This field cannot be used, only for display purposes.<\/p>\n<p>\u3010Server Name\u3011<\/p>\n<p>Set the name of the server, which can be used as a description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Security\u3011<\/p>\n<\/td>\n<td>\n<p>Security protection and encryption methods can be set, please note that this setting must be the same as the connected server:<\/p>\n<p>\u3010Security Policy\u3011<\/p>\n<p>You can specify the method of security protection, you can choose &quot;None&quot; or one of the following:<\/p>\n<ul>\n<li>Basic128Rsa15<\/li>\n<li>Basic256<\/li>\n<li>Basic256Sha256<\/li>\n<\/ul>\n<p>\u3010Message Security Mode\u3011<\/p>\n<p>You can specify the encryption mode, select &quot;None&quot; or one of the following:<\/p>\n<ul>\n<li>Sign<\/li>\n<li>Sign &amp; Encrypt<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Authentication\u3011<\/p>\n<\/td>\n<td>\n<p>The authentication method can be set. Please note that this setting must be the same as the connected server:<\/p>\n<p>\u3010Anonymous\u3011<\/p>\n<p>No authentication required<\/p>\n<p>\u3010Username\/Password\u3011<\/p>\n<p>Enter the username and password for authentication<\/p>\n<p>\u3010Certificate\u3011<\/p>\n<p>Import the certificate file and private key, and enter the corresponding private key password.<\/p>\n<p>After entering the password, it will be masked<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Update Mode\u3011<\/p>\n<\/td>\n<td>\n<p>Select the mode for updating tag data<\/p>\n<p>\u3010Subscribe\u3011<\/p>\n<p>A fixed time (milliseconds) can be set to read the tag data, read the data when it has been updated.<\/p>\n<p>\u3010Request\u3011<\/p>\n<p>Will continue to read tag data<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>16.2.3 FATEK OPC UA Client Tool<\/h4>\n<p>When running an OPC UA project using &quot;Simulation&quot; or &quot;FvRT,&quot; the &quot;Client Tool&quot; will appear on the screen (supported from version 1.6.66 onwards). This tool can be used to view information about tags in the server.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-017.png\" \/><\/p>\n<p>Figure 209\u3010FATEK OPC UA Client Tool\u3011setting page<\/p>\n<p>Moving the mouse cursor over various options will display tooltips.<\/p>\n<p>For example, <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-018.png\" \/>options like &quot;Connect,&quot; &quot;Disconnect,&quot; and &quot;Security Settings&quot; will appear.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-16\/p5hmi-fvd-en-16-019.png\" \/>&quot;Read&quot; and &quot;Write&quot; options will also appear, and if you want to modify values using this tool, you need to click after entering the values.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>OPC UA (OPC Unified Architecture) is a communication st [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3358","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3358"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3358\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}