{"id":3366,"date":"2026-11-17T18:43:09","date_gmt":"2026-11-17T10:43:09","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-24\/"},"modified":"2026-11-17T18:43:09","modified_gmt":"2026-11-17T10:43:09","slug":"p5hmi-fvd-en-24","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-24\/","title":{"rendered":"Chapter 24 HMI System Settings"},"content":{"rendered":"<p>When the user needs to change the system settings of the HMI, such as IP, buzzer, and system time, users can enter to the\u3010System Setting\u3011to modify. The\u3010System Setting\u3011function can be used directly on the HMI, or can be modified remotely through the network connection with the\u3010Remote System Setting\u3011tool.<\/p>\n<h3>24.1 How To Enter System Setting<\/h3>\n<p>Press and hold down the right side of the screen during the HMI start-up process to enter the\u3010System Setting\u3011screen in order to change the system settings of the HMI. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-001.jpg\" \/><\/p>\n<p>Figure 474 System Setting home page for HMI<\/p>\n<h3>24.2 \u3010System Setting\u3011Options<\/h3>\n<h4>24.2.1 Run Project<\/h4>\n<p>The system will automatically detect the current firmware, integrity, and compatibility of the project on the HMI when entering the\u3010System Setting\u3011. If the system determines that the firmware and project versions are compatible and the file is complete with no corruptions, it will enable the\u3010Run Project\u3011and the user can execute the project on the HMI. If the system determines that the version is incompatible or that the file is corrupted, \u3010Run Project\u3011will be locked, refer to chapter24.3-System Booting Sequence.<\/p>\n<h4>24.2.2 \u3010COM Port\u3011<\/h4>\n<p>The\u3010COM Port\u3011data page will appear after pressing the\u3010COM Port\u3011block, as shown in the figure below. This is where the COM Port details for the DB-9 male\/terminal adapter of the HMI can be found. Pressing\u3010OK\u3011on the top-right corner or\u3010Cancel\u3011on the top-left corner will exit this page.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-002.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-003.png\" \/><\/p>\n<p>Figure 475 COM Port data page<\/p>\n<h4>24.2.3 \u3010Network\u3011<\/h4>\n<p>The\u3010Network\u3011settings will appear after pressing the\u3010Network\u3011block, the setting page is divided into\u3010General\u3011,\u3010DNS\u3011,\u3010Access Control\u3011, and\u3010Wi-Fi\u3011paging. When the setting is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<h5>24.2.3.1 \u3010Ethernet\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-004.png\" \/><\/p>\n<p>Figure 476\u3010Network\u3011\u3010Ethernet\u3011paging<\/p>\n<p>Table 275\u3010Network\u3011\u3010Ethernet\u3011paging options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable LAN0\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to enable\u3010Network\u3011: Selecting\u3010Enable\u3011will allow users to continue setting the follow-up options; selecting\u3010Cancel\u3011will close the follow-up options and they cannot be set.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010MAC Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The MAC address of the HMI is displayed here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010DHCP\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select whether to enable\u3010Enable DHCP\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the IP address of the HMI here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Net Mask\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the sub-net mask of the HMI here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Gateway\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the gateway of the HMI here.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.3.2 \u3010DNS\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-005.png\" \/><\/p>\n<p>Figure 477\u3010Network\u3011\u3010DNS\u3011paging<\/p>\n<p>Table 276\u3010Network\u3011\u3010DNS\u3011paging options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010DNS\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Can set 2 DNS settings<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.3.3 \u3010Access Control\u3011<\/h5>\n<p>\u3010Access Control\u3011function can provide users to filter the connection IP or MAC address.<\/p>\n<p><strong>Note: This function only supports P5 series. The required operating system version is OS 2.0.13 or later.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-006.png\" \/><\/p>\n<p>Figure 478\u3010Network\u3011\u3010Access Control\u3011paging<\/p>\n<p>Table 277\u3010Network\u3011\u3010Access Control\u3011paging options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Access\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select whether to enable the\u3010Access Control\u3011function.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Filter Type\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Allow: Allow connection list<\/p>\n<p>Deny: Deny connection list<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP List\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check to enable IP filtering list, up to 10 groups can be set.<\/p>\n<p>When adding an IP list, you will enter the\u3010Filter Address\u3011page. There are 3 rules to choose:<\/p>\n<p>\u3010Singal\u3011: Enter a set of IP addresses to be filtered<\/p>\n<p>\u3010Subnet (CIDR Format)\u3011: Enter a set of IP addresses and subnet mask to be filtered<\/p>\n<p>\u3010Range\u3011: Enter two sets of IP, the IP within the range will be filtered<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010MAC List\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check to enable MAC filtering list, up to 10 groups can be set.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-007.png\" \/><\/p>\n<\/td>\n<td>\n<p>Add item<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-008.png\" \/><\/p>\n<\/td>\n<td>\n<p>Remove the selected item<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-009.png\" \/><\/p>\n<\/td>\n<td>\n<p>Modify the selected item<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.3.4 \u3010Wi-Fi\u3011<\/h5>\n<p>HMI can use Wi-Fi Dongle for wireless Internet access, please notice that the HMI <\/p>\n<p>Table 278 Wi-Fi Dongles support table<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>OS version:OS 2.0.14\/ firmware version:1.5.74 or above are only supported<\/p>\n<\/td>\n<td>\n<p>OS version:OS 2.0.24\/ firmware version:1.6.69 or above are only supported <\/p>\n<p>(update)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>D-Link DWA-182<\/p>\n<\/td>\n<td>\n<p>D-Link\u00a0\u00a0DWA-171<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>TP-Link Archer T3U | AC1300 MU-MIMO<\/p>\n<\/td>\n<td>\n<p>D-Link\u00a0\u00a0DWA-185<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ASUS USB-AC53NANO AC1200<\/p>\n<\/td>\n<td>\n<p>MERCURY\u00a0\u00a0MW150US<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>MERCURY\u00a0\u00a0MU6H<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-010.png\" \/><\/p>\n<p>Figure 479\u3010Network\u3011\u3010Wi-Fi\u3011paging<\/p>\n<p>Table 279\u3010Network\u3011\u3010Wi-Fi\u3011paging options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Wi-Fi\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select whether to enable the\u3010Wi-Fi\u3011function.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Access Point\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the access point to connect.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-011.png\" \/><\/p>\n<p>Figure 480\u3010Wi-Fi\u3011\u3010Access Point\u3011setting paging<\/p>\n<p>Click the <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-012.png\" \/> icon to read the searched access point. The reading time takes a few seconds. After the searching is completed, you can select the access point to connect, click Connect and enter the password, or click Search to search the specified access point that it does not exist on the list, and when a checkmark <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-013.png\" \/> appears in front of the access point, it means the connection is successful.<\/p>\n<h5>24.2.3.5 \u30104G Dongle\u3011<\/h5>\n<p>HMI can use 4G SIM card for wireless Internet access, please note that HMI firmware version: 1.5.32 \/ OS version: OS 2.0.4 or above is supported<\/p>\n<p>No special settings are required to use the 4G SIM card to access the Internet. <\/p>\n<p>Only supports the model: D-Link DWM-222 (please contact us if you need it)<\/p>\n<p>Hardware Spec: A1<\/p>\n<p>Firmware Spec: V2.0.6<\/p>\n<h4>24.2.4 \u3010Servers\/IoT\u3011<\/h4>\n<p>The\u3010Servers\/IoT\u3011settings will appear after pressing the\u3010Servers\/IoT\u3011block as shown in the figure below. The settings page are be divided into three paging:\u3010Enable FTP Server\u3011,\u3010Enable VNC Server\u3011,\u3010Pass Through\u3011,and\u3010IoT\u3011. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<h5>24.2.4.1 \u3010FTP\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-014.jpg\" \/><\/p>\n<p>Figure 481\u3010Servers\/IoT Setting\u3011\u3010FTP\u3011paging<\/p>\n<p>Table 280 Options of\u3010Servers\/IoT Setting\u3011\u3010FTP\u3011to Enable FTP Server in the Server page<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable FTP Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to\u3010Enable FTP Server\u3011. Selecting this option will allow users to continue setting the follow-up options. If this option is not selected, the follow-up options will be closed and cannot be set.<\/p>\n<p><strong>Note: If the Enable FTP Server is selected, please remember to set\u3010Read-Only Account\u3011or\u3010Read-Write Account\u3011, or else the setting cannot be completed.<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the port used by FTP Server.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable Read-Only Account\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to enable a read-only account. The user account and password can be set below once this option is selected.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable Read-Write Account\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to enable a read-write account. The user account and password can be set below once this option is selected.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mask Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The password will be masked once this option is selected.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.4.2 \u3010VNC\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-015.jpg\" \/><\/p>\n<p>Figure 482\u3010Servers\/IoT Setting\u3011\u3010VNC\u3011paging<\/p>\n<p>Table 281 Options of\u3010Servers\/IoT Setting\u3011\u3010VNC\u3011to Enable VNC Server in the Server page<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable VNC Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to\u3010Enable VNC Server\u3011. Selecting this option will allow users to continue setting the follow-up options. If this option is not selected, the follow-up options will be closed and cannot be set.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connections\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set how many VNC clients can be connected to this VNC server, the maximum number of support will vary depending on the model.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mask Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The password will be masked if this option is selected.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the port of the VNC, only the first client\u2019s port can be set, the second one will automatically increase, for example, the first one set 5900, then the second one will be 5901.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Enter the password for the VNC server.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.4.3 \u3010Pass Through\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-016.jpg\" \/><\/p>\n<p>Figure 483\u3010Servers\/IoT Setting\u3011\u3010Pass Through\u3011paging<\/p>\n<p>Table 282\u3010Servers\/IoT Setting\u3011\u3010Pass Through\u3011paging<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Pass Through Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the port used for pass through.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.4.4 \u3010IoT\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-017.jpg\" \/><\/p>\n<p>Figure 484\u3010Servers\/IoT Setting\u3011\u3010IoT\u3011paging<\/p>\n<p>Table 283\u3010Servers\/IoT Setting\u3011\u3010IoT\u3011paging<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable IoT Services (iMonitor\/iAceess)\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Host\u3011<\/p>\n<p>Set the server to connect, including worldwild version(fatekcloud.net) and China version(fatekiot.cn).<\/p>\n<p>\u3010HWID\u3011<\/p>\n<p>HMI\u2019s hardware ID, is unique and cannot be modified.<\/p>\n<p>\u3010Service Password\u3011<\/p>\n<p>When planning the IoT configuration on the IoT website, it needs this password to connected to HMI.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Enable iAceess\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010LID\u3011<\/p>\n<p>Key to activate the iAccess function.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-018.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>\u3010Button Check\u3011<\/p>\n<p>After entering the\u3010Service Password\u3011or\u3010LID\u3011, press this button to connect to the server for validity verification.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-019.jpg\" \/> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-020.jpg\" \/><\/p>\n<\/td>\n<td>\n<p>It will turn green after verification, and red if verification fails.<\/p>\n<p>Press the button behind\u3010Service Password\u3011, it will display check is valid or invalid<\/p>\n<p>Press the button behind\u3010LID\u3011to display whether the check is valid or invalid. If it is valid, it will display the available functions<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The cloud user manul can be download from the official website: <a href=\"http:\/\/www.fatek.com\/zh-tw\/download.php?act=list&amp;cid=16\">http:\/\/www.fatek.com\/zh-tw\/download.php?act=list&amp;cid=16<\/a><\/p>\n<h4>24.2.5 \u3010Link\u3011<\/h4>\n<p>The\u3010Link\u3011settings will appear after pressing the\u3010Link\u3011block, as shown in the figure below. Introductions to the options are as listed in the table below. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-021.jpg\" \/><\/p>\n<p>Figure 485\u3010Link\u3011setting page<\/p>\n<p>Table 284\u3010Link\u3011setting page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Selet the link to modify.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010State\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>This option is only to control the link status, parameter setting is not included.<\/p>\n<p>\u3010No Change\u3011<\/p>\n<p>The latest link state will not change.<\/p>\n<p>\u3010Enable\u3011<\/p>\n<p>The link-state will be enabled(connecting) when running the project.<\/p>\n<p>\u3010Disable\u3011<\/p>\n<p>The link-state will be disabled(close) when running the project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Apply\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>After modifying each setting, you must press\u3010Apply\u3011and then\u3010OK\u3011a and\u3010Execute Project\u3011will record the modified content, if you only press OK, it will not be changed.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Here only introduce the settings only in the HMI, other communication parameter please refer to chapter0-<\/p>\n<p>Link.<\/p>\n<h4>24.2.6 \u3010Display\u3011<\/h4>\n<p>The\u3010Display\u3011settings will appear after pressing the\u3010Display\u3011block, as shown in the figure below. Introductions to the options are as listed in the table below. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-022.jpg\" \/><\/p>\n<p>Figure 486\u3010Display\u3011setting page<\/p>\n<p>Table 285\u3010Display\u3011setting page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Language\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the language displayed in\u3010System Setting\u3011. The available language selections is English, Traditional Chinese, Simplified Chinese, and T\u00fcrk\u00e7e.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Rotation\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the rotation of the HMI display screen. Changes will take take effect after the system is rebooted.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Brightness\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set the needed brightness, the selectable range is 30-100, and the default is 100.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Use Screen Saver\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set whether to enable the screen saver, set the time if the function is enabled.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Use Backlight Saver\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set whether to enable the backlight saver, set the time if the function is enabled.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>24.2.7 \u3010Calibration\u3011<\/h4>\n<p>The\u3010Calibration\u3011settings will appear after pressing the\u3010Calibration\u3011block. After entering the calibrations screen, follow the instructions to complete the calibration. Do not turn off the power before finishing the calibration.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-023.jpg\" \/> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-024.jpg\" \/><\/p>\n<p>Figure 487\u3010Calibration\u3011page<\/p>\n<p>There are 5 cross-calibration points. After pressing them in sequence, a green square will appear to confirm whether the calibration is successful. If failed for 3 times, you will need to do the calibration again.<\/p>\n<p>If the error detected for the touch panel is too great resulting in users unable to properly click this\u3010Calibration\u3011block, users can then press and hold any point under the system setting page for ten seconds to enter the calibration mode.<\/p>\n<h4>24.2.8 \u3010Time\u3011<\/h4>\n<p>The\u3010Time\u3011settings will appear after pressing the\u3010Time\u3011block, as shown in the figure below. Introductions to the options are as listed in the table below. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-025.jpg\" \/><\/p>\n<p>Figure 488\u3010Time\u3011setting page<\/p>\n<p>Table 286\u3010Time\u3011setting page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Calender\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the calender of the HMI, includes Gregorain calender and Persian calender.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Date\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The system date of the HMI can be set here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The system time of the HMI can be set here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Time Zone\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The time zone of the HMI can be set here. After completing the settings, press \u3010OK\u3011 in the upper right corner to save. Restart the device and wait 5 minutes for the time to update to the configured time zone.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010NTP\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Here you can choose whether to enable network time synchronization (NTP time synchronization), enabling this feature requires setting time zone and DNS in order to effectively use.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010NTP Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Users can connect to their own server or any other servers or the default server to synchronize the time.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>24.2.9 \u3010System Info\u3011<\/h4>\n<p>The\u3010System Info\u3011settings will appear after pressing the\u3010System Info\u3011block, as shown in the figure below. Introductions to the options are as listed in the table below. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-026.jpg\" \/><\/p>\n<p>Figure 489\u3010System Info\u3011setting page<\/p>\n<p>Table 287\u3010System Info\u3011setting page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device Name\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The device name of the HMI can be set here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Station Number\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The station number of the HMI can be set here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010System Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select to enable\u3010System Password\u3011here. If\u3010System Password\u3011is enabled, the password must be set below. This password must be entered in order to set the locked option once\u3010System Password\u3011is enabled.<\/p>\n<p>Select the locked option, select the options which need enter\u3010System Password\u3011<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\ChenWu\\Desktop\\document_pic\\EN\\2015-02-10_135458.png\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-027.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010OS Version\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Information on the operating system version can be viewed here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Firmware Version\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Information on the firmware version can be viewed here.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Last Update Time\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Display the last update time for the Project, Firmware, and Environment Package.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>24.2.10 \u3010MISC\u3011<\/h4>\n<p>The\u3010MISC\u3011settings will appear after pressing the\u3010MISC\u3011block, as shown in the figure below. Introductions to the options are as listed in the table below. When configuration is complete, press the\u3010OK\u3011button on the top-right corner to save the settings and exit this page or the\u3010Cancel\u3011button on the top-left corner to discard the changes and exit this page.<\/p>\n<h5>24.2.10.1 \u3010General\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-028.png\" \/><\/p>\n<p>Figure 490\u3010MISC\u3011\u3010General\u3011setting page<\/p>\n<p>Table 288\u3010MISC\u3011\u3010General\u3011settings page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Factory Reset\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The system setting of the HMI can be re-set to the factory settings here.<\/p>\n<p>The following window will appear after this option is pressed, asking whether to continue.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-029.png\" \/><\/p>\n<p>Selecting\u3010OK\u3011will restore the HMI to factory settings and selecting\u3010Cancel\u3011will cancel this operation.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Buzzer\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>This option enables the buzzer. Close will turn the buzzer off.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Audio\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Audio can be played back if this option is enabled, otherwise it will be closed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Cursor Mode\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Here you can choose whether to display the cursor in the \u3010System Setting\u3011screen.<\/p>\n<p>(Note: This function only supports display during system settings)<\/p>\n<p>\u3010Show\u3011<\/p>\n<p>Display cursor<\/p>\n<p>\u3010Hide\u3011<\/p>\n<p>Do not show the cursor<\/p>\n<p>\u3010According to the mouse\u3011 <\/p>\n<p>The mouse will not be displayed without the mouse, and it will be displayed when the mouse is inserted.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.10.2 \u3010Security\u3011<\/h5>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-030.png\" \/><\/p>\n<p>Figure 491\u3010MISC\u3011\u3010Security\u3011setting page<\/p>\n<p>Table 289\u3010MISC\u3011\u3010Security\u3011settings page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remote Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set here whether to enable\u3010Remote Password\u3011, if you choose to enable\u3010Remote Password\u3011, you must continue to set the password below. After selecting enable \u3010Remote Password\u3011,\u3010Remote Setting\u3011needs to enter\u3010Remote Password\u3011or\u3010System Password\u3011to enter\u3010System Setting\u3011.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Customer ID\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Set here whether to enable\u3010Customer ID\u3011. If you choose to enable\u3010Customer ID\u3011, you must continue to set the password below.<\/p>\n<p>When the project is executed, it will check whether the password set here is the same as the password of\u3010Security\u3011in\u3010Project Information\u3011.<\/p>\n<p>If they are the same, it will enter the customer planning project screen.<\/p>\n<p>If they are not the same, the HMI will stay on the boot screen and a prompt message indicating that the customer ID does not match will appear. At this time, the touch function, serial port, USB port and Ethernet port communication functions will be turned off. Cannot communicate with the PLC, and the customer cannot download through computer software. If the customer needs to download the project again, he must enter the HMI\u3010System Setting\u3011screen to download again.<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td>\n<p><strong>HMI without ID<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>HMI with ID<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Project without ID<\/strong><\/p>\n<\/td>\n<td>\n<p>The project is running normally<\/p>\n<\/td>\n<td>\n<p>The project is running normally<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Project with ID<\/strong><\/p>\n<\/td>\n<td>\n<p>Can&#8217;t enter project<\/p>\n<\/td>\n<td>\n<p><strong>Same password:<\/strong> normal operation<\/p>\n<p><strong>Different passwords:<\/strong> can&#8217;t enter project<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>For instructions on how to set the customer identification code in the project, please refer to the corresponding section 3.1.4-Project Security<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.10.3 \u3010Copy Project\u3011<\/h5>\n<p>Before the connection, please follow chapter 2.2.2.5-Make USB Flash Drive Update File, put the generated .uferp under HMI Internal folder file through\u3010File Transfer\u3011.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-031.png\" \/><\/p>\n<p>Figure 492\u3010MISC\u3011\u3010Copy Project\u3011schematic<\/p>\n<p><strong>Step<\/strong><\/p>\n<ol>\n<li>The path to put the project&#8217;s USB update file (uferp) into the HMI A is: internal\/Project.uferp<\/li>\n<li>Select the connection method from the system setting page of HMI A and press the start button<\/li>\n<li>Enter the project download password (if have) in HMI A<\/li>\n<li>Wait for the copying to complete, HMI B will update the project<\/li>\n<\/ol>\n<p><strong>Note 1: When generating the .uferp file, the &#8216;delete other&#8217; option cannot select, otherwise the update will fail.<\/strong><\/p>\n<p><strong>Note 2: The two HMI models must be the same to copy the project.<\/strong><\/p>\n<p><strong>Note 3: The file name must be Project.uferp otherwise the system can\u2019t find it.<\/strong><\/p>\n<p><strong>Note4: If the download passwords of HMI A and HMI B are different, A will ask for the password; if they are the same, it will not be asked.<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-032.png\" \/><\/p>\n<p>Figure 493\u3010MISC\u3011\u3010Copy Project\u3011setting page<\/p>\n<p>Table 290\u3010MISC\u3011\u3010Copy Project\u3011settings page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Connection\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the connection way for the HMI to copy the project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010COM Port\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select the COM port to use.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Keep Update file on target device\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Select whether to keep the .uferp file on the updated HMI.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Copy Project\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press the button to start to copy the project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Delete Update file\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Delete the .uferp file under the Internal folder.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.10.4 \u3010Update Project\u3011<\/h5>\n<p>User can update project without using computer.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-033.png\" \/><\/p>\n<p>Figure 494\u3010MISC\u3011\u3010Update Project\u3011setting page<\/p>\n<p>Table 291\u3010MISC\u3011\u3010Copy Project\u3011settings page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Update Project\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Update the .uferp file from HMI internal space, SD card, or USB flash disk.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-034.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.10.5 \u3010Backup\u3011<\/h5>\n<p>Backup the data that stores in the $U:XNV register into a package so that it can easily copy to another HMI.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-035.png\" \/><\/p>\n<p>Figure 495\u3010MISC\u3011\u3010Backup\u3011setting page<\/p>\n<p>Table 292\u3010MISC\u3011\u3010Backup\u3011settings page options<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010$U:XNV register\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Import\u3011<\/p>\n<p>Import the .xnv_backup file from the folder HMI\/internal\/xnvbackup.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-036.png\" \/><\/p>\n<p>\u3010Export\u3011<\/p>\n<p>According to the HMI model and select the register type you want to export.<\/p>\n<p>The export .xnv_backup file will store under the folder HMI\/internal\/xnvbackup.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-037.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>24.2.10.6 \u3010Reboot\u3011<\/h5>\n<p>Reboot the HMI.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-038.png\" \/><\/p>\n<p>Figure 496\u3010MISC\u3011\u3010Reboot\u3011setting page<\/p>\n<h3>24.3 System Booting Sequence<\/h3>\n<p>The system will automatically detect the current firmware, integrity, and compatibility of the project on the HMI when starting up. If the system detected that the version is incompatible or that the file is corrupted resulting in the HMI being unable to start up properly, the system will automatically enter the\u3010System Setting\u3011and lock the\u3010Run Project\u3011switch. This is when users should use the download function of the FvDesigner to sequentially download the firmware and project.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-24\/p5hmi-fvd-en-24-039.jpg\" \/><\/p>\n<p>Figure 497 project error detection<\/p>\n<p>If the firmware and project were both enabled normally, the system will skip the\u3010System Setting\u3011during start-up and run the project immediately. In this case, the user must press and hold the right side of the HMI screen during the start-up until it enters the System Setting screen if the user wants to adjust the system settings.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>When the user needs to change the system settings of th [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3366","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3366","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3366"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3366\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3366"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3366"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3366"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}