{"id":3369,"date":"2026-11-17T18:43:14","date_gmt":"2026-11-17T10:43:14","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-27\/"},"modified":"2026-11-17T18:43:14","modified_gmt":"2026-11-17T10:43:14","slug":"p5hmi-fvd-en-27","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-27\/","title":{"rendered":"Chapter 27 PLC Integration"},"content":{"rendered":"<p>\u3010PLC Integration\u3011provides designers or users in pratical applications of HMI and PLC to achieve closer integration. For example, in practical applications users can show or view the current connection of <strong>WinProladder<\/strong> through HMI, no need to link PLC to PC to view Ladder diagram program of <strong>WinProladder,<\/strong> let users easy to use and debug.<br \/>Currently \u3010PLC Integration\u3011includes\u3010Show Ladder Viewer\u3011,\u3010Update FATEK PLC Project From USB\u3011,\u3010Show Ethernet Module Configuration\u3011<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-001.jpg\" \/><\/p>\n<p>Figure 505 HMI show PLC Ladder Diagram Program illustration<\/p>\n<h3>27.1  Show Ladder Viewer<\/h3>\n<p>This section will explain how to show Ladder Diagram Program of PLC (FATEK PLC) on HMI and show the interface of PLC Ladder Diagram Program which includes the meaning of options and settings.<\/p>\n<p><strong>Note 1 : The 4.3-inch HMI does not support the display of the Ladder Viewer function,<\/strong> <strong>such as P5043S or P5043N.<\/strong><\/p>\n<p><strong>Note 2 :<\/strong> <strong>FATEK FBe PLC does not support<\/strong><\/p>\n<h4>27.1.1 \u3010Show Ladder Viewer\u3011Applications and Settings<\/h4>\n<p>For example, use FATEK P5 series HMI connted with FATEK FBs series PLC, and hope in the P5 series HMI display and view the FBs series PLC ladder diagram program, Set the following steps:<\/p>\n<p>Step 1:\u3010Toolbox\u3011\u3010Lamp\/Switch\u3011drag a\u3010Function Switch\u3011to windows\uff0cas shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\441.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-002.jpg\" \/><\/p>\n<p>Figure 506 drag a\u3010Function Switch\u3011to window<\/p>\n<p>Step 2: double click Function Switch to enter Function Switch Properties, and in this dialog window by the &quot;function&quot; drop-down menu, select \u3010PLC: Show ladder viewer\u3011, as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-003.png\" \/><\/p>\n<p>Figure 507 select\u3010PLC: Show ladder viewer\u3011dialog<\/p>\n<p>Step 3: set the connection of HMI and PLC, then compile and download to HMI, through the connection, press the \u3010Function Switch\u3011\u3010PLC: Show ladder viewer\u3011, will appear link device dialog, as show below, the device name is the name of the device in the software link setting.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\443.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-004.jpg\" \/><\/p>\n<p>Figure 508 The menu dialog of the linked device<\/p>\n<p><strong>Note: in off-line simulation, press\u3010Function Switch\u3011will not appear link device dialog, but will appear in HMI interface, microSD or USB storage devices, choose the PLC project(*.pdw) loading dialog window.<\/strong><\/p>\n<p>Step 4: choose the device, then it will load the PLC ladder diagram program, as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-005.png\" \/><\/p>\n<p>Figure 509 show PLC ladder diagram program<\/p>\n<h4>27.1.2 HMI display the interface of PLC ladder diagram program<\/h4>\n<p>The interface of the PLC ladder program is displayed on the HMI, as shown below.<\/p>\n<p>The meaning of each settings, as shown in the table below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-006.png\" \/><\/p>\n<p>Figure 510 The interface of the PLC ladder diagram is displayed on the HMI<\/p>\n<p>Table 296 shows the attributes of the PLC ladder diagram interface on the HMI<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Property<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Display Settings\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-007.jpg\" \/>, will display the settings dialog window, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_1.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-008.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Comment\u3011<\/p>\n<p>Click on the box that says \u201cComment\u201d and the following dialog window will pop up, as show below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_2.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-009.jpg\" \/><\/p>\n<p>\u3010Comment Visible\u3011<\/p>\n<p>Set whether the comments in the ladder diagram are displayed. <\/p>\n<p>\u3010Section Comment Visible\u3011<\/p>\n<p>Set whether the program area comments in the ladder program is displayed. The current preset is disabled and cannot be checked.<\/p>\n<p>\u3010Network Comment Visible\u3011<\/p>\n<p>Set whether the network comment in the ladder program is displayed. The current preset is disabled and cannot be checked. <\/p>\n<p>\u3010Element Comment Visible\u3011<\/p>\n<p>Set whether the element comment in the ladder program is displayed. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Language\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Language\u3011<\/p>\n<p>In this window, you can select the language of your comments in the ladder program. Languages include English, Traditional Chinese, Simplified Chinese, Other Language, and so on.<\/p>\n<p>Selectable languages should be added from\u3010Font Library\u3011.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_3.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-010.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Block Open\/ Close\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>This option is mainly for the WinProLadder block close and block open function(Need to cooperate with Fun199). Click on the button and the following dialog window will pop up, the HMI will activity to search the ladder diagram that those networks are block closed then list it, operators can choose which networks are open or close(If the original close block has a set password, need to enter password to open the block password), press OK to see ladder diagram.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-011.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Reload\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Reload\u3011<\/p>\n<p>Reload the ladder program.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Zoom in\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-012.jpg\" \/>, will zoom in on the HMI ladder diagram.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Zoom out\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-013.jpg\" \/>, will zoom out on the HMI ladder diagram.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010PLC Status Information\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-014.jpg\" \/>, will pop up PLC status information window, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_4.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-015.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Switch between the MainSection and the SubSection program\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-016.jpg\" \/>, switch between the MainSection and the SubSection program.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Search\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-017.jpg\" \/>, the dialog window for the address search will pop up, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_5.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-018.jpg\" \/><\/p>\n<p>\u3010Find\u3011<\/p>\n<p>Search type and address.<\/p>\n<p>\u3010Goto\u3011<\/p>\n<p>Can jump to host program or subprogram network number <\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t270_7.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-019.jpg\" \/><\/p>\n<p>\u3010Register Type\/Network Number\u3011<\/p>\n<p>Enter the type and address you want to search for or jump to the host or subprogram network number<\/p>\n<p>\u3010Filter\u3011<\/p>\n<p>Filter the type of search, including contacts, coils, functional instructions, and all, etc.<\/p>\n<p>\u3010Start Position\u3011<\/p>\n<p>Start position, including automatic and current location.<\/p>\n<p>\u3010Searching Direction\u3011<\/p>\n<p>Searching Direction, including move up and move down, etc.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Quit the ladder diagram window\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-020.jpg\" \/>, will quit the ladder diagram window.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Move up\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-021.jpg\" \/>, the ladder diagram will be viewed above.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Move down\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-022.jpg\" \/>, the ladder diagram will be viewed below.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Move right\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-023.jpg\" \/>, the ladder diagram will be viewed right.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Move left\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-024.jpg\" \/>, the ladder diagram will be viewed left.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Network No.\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>This icon <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-025.jpg\" \/>is Network No. for the ladder diagram.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>27.2 Update FATEK PLC Project From HMI or USB Flash Drive<\/h3>\n<p>This section explains how to update the ladder program of a connected PLC using the HMI\u2019s internal storage or a USB storage device.<\/p>\n<p>Step 1:<\/p>\n<p>Select\u3010PLC: Update FATEK PLC Project From HMI or USB Flash Drive\u3011from the \u3010Function Switch\u3011in FvDesigner.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-026.png\" \/><\/p>\n<p>Figure 511 Update PLC program step 1<\/p>\n<p>Step 2: <\/p>\n<p>Place the PLC program in the HMI internal storage or on a USB flash drive. After pressing the function button in the project, you can select the PLC program you want to download. The software will display the corresponding device according to the selected file (for example, if a .pdw file is selected, only FBs series PLCs can be chosen). After that, the download process can begin.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-027.png\" \/> <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-028.png\" \/><\/p>\n<p>Figure 512 Update PLC program step 2<\/p>\n<p>The following explains how to obtain programs for FBs and MPLC series.<\/p>\n<p><strong>FBs Series \u2013 WinProladder<\/strong><\/p>\n<p>When saving the file in WinProladder, select\u3010Project file\u3011to generate the\u3010.pdw\u3011file.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-029.png\" \/><\/p>\n<p>Figure 513 How to get pdw file<\/p>\n<p><strong>MPLC Series \u2013 UperLogic <\/strong>(Supported in <strong>FvDesigner v1.6.83 \/ v1.7.07 or later<\/strong>, and <strong>UperLogic v1.0.10 or later<\/strong>)<\/p>\n<p>When saving the file in <strong>UperLogic<\/strong>, select <strong>Export UperLogic Pack File<\/strong>, and check the parameter <strong>Use for FATEK HMI<\/strong>.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-030.jpg\" \/><\/p>\n<p>Figure 514 How to get upfx file<\/p>\n<p><strong>\u203bNotice: When running in\u3010.pdwOffline Simulation\u3011, pressing this function will have no effect.<\/strong><\/p>\n<h3>27.3 \u3010FATEK PLC Transfer Encrypt Tool\u3011<\/h3>\n<p>This chapter explains how to use the USB storage device of HMI to update the connected FATEK PLC ladder diagram program, how to protect the operation flow, and protect the designer&#8217;s planned PLC ladder diagram program and intellectual property, etc.<\/p>\n<p>Use the USB storage device of HMI to update the connected FATEK PLC ladder diagram program divide it into 2 parts. <\/p>\n<p>The first part, if you do not need to protect the PLC project, you can directly copy the PLC project (*.pdw) planned by FATEK PLC software to the USB storage device, microSD card, or through FTP function transfer the PLC project to the HMI internal storage, and follow-up will be able to update the FATEK PLC project according to chapter 0-<\/p>\n<p>Update FATEK PLC Project From HMI or USB .<\/p>\n<p>In the second part, if the PLC project needs to be protected, it is necessary to follow the follow-up instructions to generate the designer&#8217;s all transfer password or single pass password and conversion file, etc., so that the designer&#8217;s planned PLC ladder diagram program can be protected. The following describes how to set and use transfer passwords, single passwords, and conversion files.<\/p>\n<h4>27.3.1 \u3010FATEK PLC Transfer Project Generator\u3011<\/h4>\n<p>This chapter will explain how to use the USB storage device HMI to update the connected FATEK PLC ladder diagram program, and the PLC project needs to be protected. How to set the\u3010Transfer Password\u3011and convert the file, etc. This can be achieved through the\u3010FATEK PLC Transfer Encrypt Tool\u3011provided by FvDesigner.<\/p>\n<p>If only set\u3010Transfer Password\u3011, it\u2019s available for unlimited downloads, in other words, you can update the connected FATEK PLC ladder diagram program for an unlimited number of times.<\/p>\n<p>\u3010FATEK PLC Transfer Project Generator\u3011can be found on the Tools tab on the FvDesigner ribbon, after select the\u3010FATEK PLC Transfer Encrypt Tool\u3011drop-down menu then click\u3010FATEK PLC Transfer Project Generator\u3011options to do the setting.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-031.png\" \/><\/p>\n<p>Figure 515\u3010FATEK PLC Transfer Project Generator\u3011option<\/p>\n<p>The\u3010FATEK PLC Transfer Project Generator\u3011page is shown in the figure below. The meaning of each setting option is as follows:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-032.jpg\" \/><\/p>\n<p>Figure 516\u3010FATEK PLC Transfer Project Generator\u3011setting<\/p>\n<p>Table 297\u3010FATEK PLC Transfer Project Generator\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Generate Project\u3011<\/p>\n<\/td>\n<td>\n<p>With this tool, you can convert the original FATEK PLC project (*.pdw) into an encrypted file *.tpdw and generate all the transfer passwords for the designer. <\/p>\n<p>\u3010FATEK PLC Project(.pdw)\u3011<\/p>\n<p>Set the path and file location of the original FATEK PLC project (*.pdw).<\/p>\n<p>\u3010.tpdw Output Path\u3011<\/p>\n<p>Set the path of *.tpdw to be generated. If it is not set, the default path is same as the original FATEK PLC project (*.pdw), and the converted files can no longer be opened with FATEK PLC\u2019s software WinProLadder.<\/p>\n<p>\u3010Transfer Password\u3011<\/p>\n<p>The transfer password generated by the system can update to the connected FATEK PLC ladder diagram program for an unlimited number of times.<\/p>\n<p>\u3010Random\u3011<\/p>\n<p>After pressing this button, the system will provide a new set of transfer passwords again.<\/p>\n<p>\u3010Generate Transfer Project(.tpdw)\u3011<\/p>\n<p>Press this button to generate *.tpdw file and save it in the set path.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>After setting the transfer password, you can update the FATEK PLC project according to the chapter0-<\/p>\n<p>Update FATEK PLC Project From HMI or USB , but when selecting the FATEK PLC project, select the *.tpdw file, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\454.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-033.jpg\" \/><\/p>\n<p>Figure 517 select to update the PLC project<\/p>\n<p>Select the file, press OK, it will display \u2018\u2019Please enter password\u2019\u2019 dialogue window, as shown below, please enter the transfer password.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\455.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-034.jpg\" \/><\/p>\n<p>Figure 518 select the transfer password<\/p>\n<p>After entering the transfer password, press OK, the \u2018\u2019Select Device\u2019\u2019 dialog window will appear, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\456.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-035.jpg\" \/><\/p>\n<p>Figure 519 select device<\/p>\n<p>If the PLC wants to download the PLC program during operation, it will first ask whether to stop the PLC operation first, and then continue to update the dialogue window of the PLC program, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\457.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-036.jpg\" \/><\/p>\n<p>Figure 520 ask whether to stop the running PLC<\/p>\n<p>After finish updating the PLC project, there will be a dialogue window to start the PLC, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\458.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-037.jpg\" \/><\/p>\n<p>Figure 521 download success and ask whether to start PLC immediately<\/p>\n<h4>27.3.2 \u3010Single Pass Password Generator\u3011<\/h4>\n<p>The chapter will explain how to set\u3010Single Pass Password\u3011,\u3010Single Pass Password\u3011can only be used once. The user will generate a set of passwords from the HMI due to the operation and provide it to the designer. The designer then generates new password through the\u3010Single Pass Password Generator\u3011to enter to the HMI to update the connected FATEK PLC Ladder Diagram program.<\/p>\n<p>\u3010Single Pass Password Generator\u3011function can be selected in\u3010Tools\u3011function tab on the FvDesigner ribbon, select\u3010Fatek PLC Transfer Encrypt Tool\u3011drop-down menu, and click\u3010Single Pass Password Generator\u3011option to open function setting window.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-038.png\" \/><\/p>\n<p>Figure 522\u3010Single Pass Password Generator\u3011option<\/p>\n<p>The\u3010Single Pass Password Generator\u3011page is shown in the following figure. The meaning of each setting option is as follows:<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\460.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-039.jpg\" \/><\/p>\n<p>Figure 523\u3010Single Pass Password Generator\u3011setting window<\/p>\n<p>Table 298\u3010Single Pass Password Generator\u3011properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Generate Password\u3011<\/p>\n<\/td>\n<td>\n<p>Single pass password can be generated through this tool.<\/p>\n<p>\u3010Transfer Password\u3011<\/p>\n<p>Enter the original transfer password.<\/p>\n<p>\u3010Single Pass Key\u3011<\/p>\n<p>Enter the single pass key generated from the HMI.<\/p>\n<p>\u3010Generate Single Pass Password\u3011<\/p>\n<p>Pressing this button will generate a single pass password, which will be provided to the user for input to the HMI to update the connected FATEK PLC Ladder diagram program. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>After setting the transfer password, you can update the FATEK PLC project according to the chapter 0-<\/p>\n<p>Update FATEK PLC Project From HMI or USB, but when selecting the FATEK PLC project, select the *.tpdw file, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\454.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-040.jpg\" \/><\/p>\n<p>Figure 524 select to update the PLC project<\/p>\n<p>Select the file, press OK, the dialog box for entering the transfer password will be displayed, and click\u3010Single Pass Password\u3011, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\462.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-041.jpg\" \/><\/p>\n<p>Figure 525 select single pass password<\/p>\n<p>Provide the\u3010Single Pass Key\u3011to the designer. After the designer enters\u3010Transfer Password\u3011and\u3010Single Pass Key\u3011in\u3010Single Pass Password Generator\u3011, press\u3010Generator Single Pass Password\u3011as shown in the figure below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\463.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-042.jpg\" \/><\/p>\n<p>Figure 526\u3010Single Pass Password Generator\u3011window<\/p>\n<p>The generated\u3010Single Pass Password\u3011provide to user to enter to the HMI, as shown in the figure below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\464.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-043.jpg\" \/><\/p>\n<p>Figure 527 enter single pass password window<\/p>\n<p>After entering the single pass password, press OK, the \u2018\u2019Select Device\u2019\u2019 dialog window will appear, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\465.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-044.jpg\" \/><\/p>\n<p>Figure 528 select device<\/p>\n<p>If the PLC wants to download the PLC program during operation, it will first ask whether to stop the PLC operation first, and then continue to update the dialogue window of the PLC program, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\466.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-045.jpg\" \/><\/p>\n<p>Figure 529 ask whether to stop the running PLC<\/p>\n<p>After finish updating the PLC project, there will be a dialogue window to start the PLC, as shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\467.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-046.jpg\" \/><\/p>\n<p>Figure 530 download success and ask whether to start PLC immediately<\/p>\n<h3>27.4 Show Ethernet Module Configuration<\/h3>\n<p>This section will explain how to set up the ethernet module configuration and options and settings of FATEK PLC on the HMI display ethernet so that the user can easily use it.<\/p>\n<h4>27.4.1 \u3010Ethernet Module Configuration\u3011Application and Settings<\/h4>\n<p>For example, use FATEK P5 series HMI, Show Ethernet Module Configuration, Set the following steps:<\/p>\n<p>Step 1: \u3010Toolbox\u3011\u3010Lamp\/Switch\u3011drag a\u3010Function Switch\u3011to windows\uff0cas shown below.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\441.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-047.jpg\" \/><\/p>\n<p>Figure 531 drag a\u3010Function Switch\u3011to window<\/p>\n<p>Step 2: double click Function Switch to enter Function Switch Properties, and in this dialog window by the &quot;function&quot; drop-down menu, select \u3010PLC: Show Ethernet Module Configuration\u3011, as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-048.png\" \/><\/p>\n<p>Figure 532 select\u3010PLC: Show Ethernet Module Configuration\u3011dialog<\/p>\n<p>Step 3: set the connection of HMI and PLC, then compile and download to HMI. <\/p>\n<p>Step 4: In the HMI and PLC connection operation, press\u3010Function Switch\u3011\u3010PLC: Show Ethernet Module Configuration\u3011, a dialog window appears to update the PLC project, as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-049.jpg\" \/><\/p>\n<p>Figure 533 dialog of FATEK PLC on ethernet<\/p>\n<p><strong>Note: after pressing the\u3010Function Switch\u3011, as a result of the search on the network FATEK PLC network module will be delayed some time.<\/strong><\/p>\n<p>Table 299 properties of FATEK PLC ethernet configuration dialog<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>IP Address of ethernet configuration<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Ethernet Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Ethernet Address of ethernet configuration<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Mode\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Mode of ethernet configuration<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Annotations can be used to specify more detailed module information, up to 21 characters.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Rescan\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Rescan ethernet configuration on line, the detected module will be displayed in the middle of the window.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Properties\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Touch to display or set the module data, press this button to enter the module configuration window.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Exit\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Exit the dialog of ethenet configuration.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>27.4.2 General Settings of Ethernet Module<\/h4>\n<p>General properties of ethernet module on HMI, as shown below.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-050.jpg\" \/><\/p>\n<p>Figure 534 General properties of ethernet module<\/p>\n<p>Table 300 properties of ethernet module settings<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Optios<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP Assign Mode\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>IP Assign Mode, including static and dynamic and acquisition by the registor of PLC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010IP Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>IP Address of ethernet module.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Subnet Mask\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Subnet Mask of ethernet module.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010GateWay\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>GateWay of ethernet module.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Host Name\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Host Name, can be used to identify different module.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Comment\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Annotations can be used to specify more detailed module information, up to 21 characters.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remote Config Enabled\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check to allow Ether_Config settings to be made remotely via the Internet. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remote Web Access Enabled\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Check to allow remote through the Internet for Web pages operation.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Operation Mode\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Port1 is fixed to FATEK Server, Port2 can select the working mode according to the demand<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>27.4.3 Password Setting Page of Ethernet Module<\/h4>\n<p>Display password setting page of ethernet module on HMI, as shown below.<\/p>\n<p>The meaning of each option is as follows, as shown in the following table, please refer to the PLC network Ethernet communication module operating instructions manual<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-051.png\" \/><\/p>\n<p>Figure 535 password setting page of ethernet module<\/p>\n<p>Table 301 properties of password setting page of ethernet module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010New Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>To change the new password.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Confirm Password\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Confirm new password.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Change\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Press this button will complete the change setting.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remove\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Cancle the password.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>27.4.4 Access Control Setting Page of Ethernet Module<\/h4>\n<p>Display access control setting page of ethernet module on HMI, as shown below.<\/p>\n<p>The meaning of each option is as follows, as shown in the following table, please refer to the PLC network Ethernet communication module operating instructions manual<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-052.jpg\" \/><\/p>\n<p>Figure 536 Access Control setting page of ethernet module<\/p>\n<p>Table 302 properties of Access Setting Control page of ethernet module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Base IP Address\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The smallest IP Address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Size\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Continuous quantity.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Add\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Add an Authorization information.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Edit\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Edit an Authorization information<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Remove\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Delete an Authorization information<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>27.4.5 External Severs Setting Page of Ethernet Module<\/h4>\n<p>External Severs Setting Page of Ethernet Module on HMI, as shown below.<\/p>\n<p>The meaning of each option is as follows, as shown in the following table, please refer to the PLC network Ethernet communication module operating instructions manual<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-053.jpg\" \/><\/p>\n<p>Figure 537 External Severs setting page of ethernet module<\/p>\n<p>Table 303 properties of External Severs setting page of ethernet module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010NTP Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Network automation calibration time function.<\/p>\n<p>\u3010Enable\u3011<\/p>\n<p>Enable Network automation calibration time function.<\/p>\n<p>\u3010IP(URL)\u3011<\/p>\n<p>URL of NTP Sever<\/p>\n<p>\u3010Time Zone\u3011<\/p>\n<p>Location of the Time Zone<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010SMTP Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Function of sending Email<\/p>\n<p>\u3010IP(URL)\u3011<\/p>\n<p>URL of sending email sever.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Service CallBack Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Automatic maintenance callback function. <\/p>\n<p>\u3010Port\u3011<\/p>\n<p>Maintenance Center port number.<\/p>\n<p>\u3010IP(URL)\u3011<\/p>\n<p>Maintenance Center network address or domain name.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010DNS Server\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Domain name sever<\/p>\n<p>\u3010Primary IP\u3011<\/p>\n<p>Primary DNS Server.<\/p>\n<p>\u3010Secondary IP\u3011<\/p>\n<p>Secondary DNS Server.\t<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>27.4.6 Service Port Setting Page of Ethernet Module<\/h4>\n<p>Display service port setting page of ethernet module on HMI, as shown below.<\/p>\n<p>The meaning of each option is as follows, as shown in the following table, please refer to the PLC network Ethernet communication module operating instructions manual<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-054.jpg\" \/><\/p>\n<p>Figure 538 service port setting page of ethernet module<\/p>\n<p>Table 304 properties of service port setting page of ethernet module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Option<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Fatek Protocol\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>FATEK communication protocol service port NO.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Http Protocol\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Http communication protocol service port NO.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Modbus Protocol\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>Modbus communication protocol service port NO.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>27.5 Control PLC run\/stop from HMI<\/h3>\n<p>This chapter will introduce how to control the PLC run or stop operation from HMI.<\/p>\n<p>This function only supports for the FATEK PLC, it cannot use without FATEK PLC in the\u3010Link\u3011.<\/p>\n<h4>27.5.1 Setting the PLC run\/stop function<\/h4>\n<p>Step1: drag a\u3010Function Switch\u3011from\u3010Toolbox\u3011\u3010Lamp\/Switch\u3011to the screen.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-055.jpg\" \/><\/p>\n<p>Figure 539 drag a\u3010Function Switch\u3011to the screen<\/p>\n<p>Step2: double click the object to enter the properties setting page, select the\u3010PLC: Run PLC\u3011or\u3010PLC: Stop PLC\u3011option.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-056.png\" \/><\/p>\n<p>Figure 540 select run\/stop PLC function<\/p>\n<p>\u3010Select a device\u3011can use to directly control the specified PLC. If this option is not selected, then it will show the FATEK PLC link list to let the user choose which PLC to control.<\/p>\n<h4>27.5.2 PLC run\/stop operation steps<\/h4>\n<p>If didn\u2019t set the\u3010Select a device\u3011, then it will appear the following screen when pressing the button.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-057.jpg\" \/><\/p>\n<p>Figure 541 select the PLC device<\/p>\n<p>Click the list and select the PLC to control.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-058.jpg\" \/><\/p>\n<p>Figure 542 select the target PLC<\/p>\n<p><strong>Note: If using the PLC M1912 to stop the PLC, then cannot use this function switch to reboot the PLC.<\/strong><\/p>\n<h3>27.6 Enable and Disable PLC from HMI<\/h3>\n<p>When the user wants to adjust the on-site equipment, but is not convenient to use the computer, you can plan the enabling and disabling points in the project in advance, so as to avoid false actions during the test. The following describes how to control from the HMI.<\/p>\n<p>As shown in the figure below, when Y0 is disabled, we can\u2019t get the signal from Y0 if we trigger M1.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-059.png\" \/><\/p>\n<p>Figure 543 Disable illustration<\/p>\n<p>On the contrary, when enabled, the output can get the signal<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-27\/p5hmi-fvd-en-27-060.png\" \/><\/p>\n<p>Figure 544 Enable illustration<\/p>\n<p>The controlled address only supports X, Y, M, and S. It is supported the type start with E in the bit switch\u3010Input Address\u3011. The example is written as: @0:EY0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3010PLC Integration\u3011provides designers or users in pratica [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3369","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3369","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3369"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3369\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3369"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3369"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3369"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}