{"id":3371,"date":"2026-11-17T18:43:16","date_gmt":"2026-11-17T10:43:16","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-29\/"},"modified":"2026-11-17T18:43:16","modified_gmt":"2026-11-17T10:43:16","slug":"p5hmi-fvd-en-29","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-29\/","title":{"rendered":"Chapter 29 Multi-Link"},"content":{"rendered":"<p>\u3010Multi-Link\u3011function is to build multi-link master on FATEK HMI, other multi-link slaves on HMI can communicate with multi-link master, communicate with the\u3010Destination Link\u3011device which connect to the multi-link master. That is, the multi-link master communicate with\u3010Destination Link\u3011device it link with, multi-link slave connect with multi-link master, and get the data they need to display or setting through multi-link master. On the use of a multi-link master corresponding to a link to the\u3010Destination Link\u3011device; According the way to communicate with multi-link slave, multi-link master fall into two parts,\u3010Multi-Link Master(Ethernet)\u3011and\u3010Multi-Link Master(Serial)\u3011;\u3010Multi-Link Master(Ethernet)\u3011support\u3010IP Address Filter\u3011and\u3010Operation Lock\u3011functions<\/p>\n<p>Specification and setting and other related information of the multi-link master please refer to the following.<\/p>\n<p>Table 312 multi-link support number od slaves<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Multi-Link Master (Ethernet)<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Multi-Link Master (Serial)<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Support the number of slaves<\/strong><\/p>\n<\/td>\n<td>\n<p>32<\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Others<\/strong><\/p>\n<\/td>\n<td>\n<p>support\u3010IP Address Filter\u3011function<\/p>\n<p>support\u3010Operation Lock\u3011function<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-001.jpg\" \/><\/p>\n<p>Figure 563 multi-link application diagram<\/p>\n<h3>29.1 \u3010Multi-Link\u3011 Setting<\/h3>\n<h4>29.1.1 Serial<\/h4>\n<p>\u3010Multi-Link\u3011function support serial port to communicate with each other between master and slave. The following sections describe the settings for the master and slave serial ports.<\/p>\n<p> <img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\123.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-002.jpg\" \/><\/p>\n<p>Figure 564 Multi-Link(Serial) connection diagram<\/p>\n<p><strong>Note : The connection between master and slave must be 422\/485 in order to support more than 2 slaves. If 232 only support one <\/strong><\/p>\n<h5>29.1.1.1 Multi-Link Master(Serial) setting<\/h5>\n<p>The serial port setting of the multi-link master, need to select\u3010Interface Type\u3011\u3010Multi-Link Master(Serial)\u3011in\u3010New Link Property\u3011dialog, as shown below, the setting meaning are as follows.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-003.jpg\" \/><\/p>\n<p>Figure 565\u3010Multi-Link Master(Serial)\u3011setting page<\/p>\n<p>Table 313 properties of\u3010Multi-Link Master(Serial)\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Name\u3011<\/p>\n<p>Name of multi-link master<\/p>\n<p>\u3010Interface Type\u3011<\/p>\n<p>Interface Type of multi-link master<\/p>\n<p>\u3010Destination Link\u3011<\/p>\n<p>The destination link for the multi-link master, that is, the name of the PLC device to which the multi-link master is connected<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Port\u3011<\/p>\n<p>The port that multi-link master connect with, this port needs to connect with slave.<\/p>\n<p>\u3010Baud Rate\u3011<\/p>\n<p>Baud rate of multi-link master port, baud rate between multi-link master and slave needs to be the same, only support 38400, 57600 and 115200, etc.<\/p>\n<p>\u3010Timeout(ms)\u3011<\/p>\n<p>The waiting time before the connection is terminated when the communication between the multi-link master and slave is abnormal. <\/p>\n<p>\u3010Total Stations\u3011<\/p>\n<p>Number of slaves supported by multi-link master.<\/p>\n<p>\u3010Rescan Time\u3011<\/p>\n<p>Multi-link master excute scanning the interval time of online slaves.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>29.1.1.2 Multi-Link Slave(Serial) Setting <\/h5>\n<p>The serial port setting of the multi-link slave, need to select\u3010Interface Type\u3011\u3010Multi-Link Slave(Serial)\u3011in\u3010New Link Property\u3011dialog, as shown below, the setting meaning are as follows.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-004.jpg\" \/><\/p>\n<p>Figure 566\u3010Multi-Link Slave(Serial)\u3011setting page<\/p>\n<p>Table 314 properties of\u3010Multi-Link Slave(Serial)\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Name\u3011<\/p>\n<p>Name of multi-link slave<\/p>\n<p>\u3010Interface Type\u3011<\/p>\n<p>Interface Type of multi-link slave<\/p>\n<p>\u3010Destination Link Type\u3011<\/p>\n<p>The destination link type of multi-link slave corresponding to the multi-link master<\/p>\n<p>\u3010Manufacturer\u3011<\/p>\n<p>The destination link manufacturer of multi-link slave corresponding to the multi-link master<\/p>\n<p>\u3010Product Series\u3011<\/p>\n<p>The destination link product series of multi-link slave corresponding to the multi-link master<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Port\u3011<\/p>\n<p>The port that multi-link slave connect with, this port needs to connect with master.<\/p>\n<p>\u3010Baud Rate\u3011<\/p>\n<p>Baud rate of multi-link master port, baud rate between multi-link master and slave needs to be the same, only support 38400, 57600 and 115200, etc.<\/p>\n<p>\u3010Timeout(ms)\u3011<\/p>\n<p>When a communication error occurs, wait time before terminating the connection and generating an error<\/p>\n<p>\u3010Station No.\u3011<\/p>\n<p>Station No. of multi-link slave.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>29.1.2 Ethernet<\/h4>\n<p>\u3010Multi-Link\u3011function support ethernet to communicate with each other between master and slave. The following sections describe the settings for the master and slave ethernet.<\/p>\n<h5>29.1.2.1 Multi-Link Master(Ethernet) setting<\/h5>\n<p>The serial port setting of the multi-link master, need to select\u3010Interface Type\u3011\u3010Multi-Link Master(Ethernet)\u3011in\u3010New Link Property\u3011dialog, as shown below, the setting meaning are as follows.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-005.jpg\" \/><\/p>\n<p>Figure 567\u3010Multi-Link Master(Ethernet)\u3011setting page<\/p>\n<p>Table 315 properties of\u3010Multi-Link Master(Ethernet)\u3011setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Name\u3011<\/p>\n<p>Name of multi-link master <\/p>\n<p>\u3010Interface Type\u3011<\/p>\n<p>Interface Type of multi-link master <\/p>\n<p>\u3010Destination Link\u3011<\/p>\n<p>The destination link for the multi-link master, that is, the name of the PLC device to which the multi-link master is connected<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Port\u3011<\/p>\n<p>The port that multi-link master connect with, the port setting needs to be the same with the slave; default port is 8000<\/p>\n<p>\u3010IP filter\u3011<\/p>\n<p>When enable, the multi-link master will only allow the IP of the slaves that on the list to connect with the master<\/p>\n<p>When enable, click\u3010Setting\u3011will appear dialog as shown below, set the IP Address in\u3010IP Filter\u3011of the slave that you want to connect with.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\2.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-006.jpg\" \/><\/p>\n<p>\u3010Timeout(ms)\u3011<\/p>\n<p>The waiting time before the connection is terminated when the communication between the multi-link master and the slave is abnormal.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h5>29.1.2.2 Multi-Link Slave(Ethernet) setting<\/h5>\n<p>The serial port setting of the multi-link slave, need to select\u3010Interface Type\u3011\u3010Multi-Link Slave(Ethernet)\u3011in\u3010New Link Property\u3011dialog, as shown below, the setting meaning are as follows.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-007.jpg\" \/><\/p>\n<p>Figure 568\u3010Multi-Link Slave(Ethernet)\u3011setting page<\/p>\n<p>Table 316 properties of\u3010Multi-Link Slave(Ethernet)\u3011setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Link Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Name\u3011<\/p>\n<p>Name of multi-link slave.<\/p>\n<p>\u3010Interface Type\u3011<\/p>\n<p>Interface Type of multi-link slave.<\/p>\n<p>\u3010Destination Link Type\u3011<\/p>\n<p>The destination link type of multi-link slave corresponding to the multi-link master<\/p>\n<p>\u3010Manufacturer\u3011<\/p>\n<p>The destination link manufacturer of multi-link slave corresponding to the multi-link master<\/p>\n<p>\u3010Product series\u3011<\/p>\n<p>The destination link product series of multi-link slave corresponding to the multi-link master<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Interface Setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010IP Address\u3011<\/p>\n<p>IP Address of the slave that want to connect with the master.<\/p>\n<p>\u3010Port\u3011<\/p>\n<p>Multi-link slave connect to the ethernet port of the master<\/p>\n<p>\u3010Timeout(ms)\u3011<\/p>\n<p>When communication error occur, wait time before terminating and the connection and generating an error<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Device specific setting\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>The setting of this part needs to be the same with the device setting of the destination link of the multi-link master.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>29.2 Operation Lock<\/h3>\n<p>When the communication between the master and the slave of the\u3010Multi-Link\u3011function is used,\u3010Operation Lock\u3011function can be used on FATEK HMI, lock the other unused screen of FATEK HMI, to prevent the operation from the other FATEK HMI,to avoid the unexpected situation occurred.<\/p>\n<h4>29.2.1 Operation Lock Description<\/h4>\n<p>\u3010Operation Lock\u3011function need to be enabled at\u3010Operation Lock\u3011of the\u3010Multi-Link Master(Ethernet)\u3011link setting page, as shown Figure 567 below, there are two conditions to trigger\u3010Operation Lock\u3011, touch the HMI screen and press the\u3010Function Switch\u3011of the\u3010Operation Lock(Unclock)\u3011or\u3010Operation Lock(Lock&amp;Unclock)\u3011; there are also two ways to unlock, it will automactically unlocked after the countdown is complete and press the\u3010Function Switch\u3011of the\u3010Operation Lock(Unclock)\u3011or\u3010Operation Lock(Lock&amp;Unclock)\u3011, the setting options are as follows:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-008.jpg\" \/><\/p>\n<p>Figure 569 setting page\u3010Operation Lock\u3011<\/p>\n<p>Table 317 properties of\u3010Operation Lock\u3011setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>Options<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>\u3010Operation Lock\u3011<\/strong><\/p>\n<\/td>\n<td>\n<p>\u3010Enable Screen Touch Lock\u3011<\/p>\n<p>When enabled, touch the HMI screen to enable\u3010Operation Lock\u3011, the other multi-link HMI will go into the screen lock status.<\/p>\n<p>\u3010Timeout(sec)\u3011<\/p>\n<p>After HMI in screen lock status, if the enable\u3010Operation Lock\u3011HMI doesn\u2019t operate exceed the setting time, then the other multi-link HMI in the screen lock status will automactically unlock the screen.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>29.3 Multi-Link Eaxmple<\/h3>\n<p>This section explains how to build multi-link, and multi-link master communication with FATEK PLC, communication with slave by using serial, in this example the master use P5070N, the salve use P5043N, setting steps as follows.<\/p>\n<p>Step 1: Build the new project of the master and build link 0, select Fatek FBs\/B1\/B1z\/HB1 driver, please refer to other relevant sections for this section.<\/p>\n<p>Step 2: Add link 1,\u3010Interface Type\u3011choose multi-link master(serial),\u3010Destination Link\u3011choose link 0,\u3010Port\u3011choose COM4(COM4 RS485 of the P5070N) and link with the multi-link slave,\u3010Baud Rate\u3011choose 115200,\u3010Total Stations\u3011choose 1 link with a slave, figure as shown belown.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-009.jpg\" \/><\/p>\n<p>Figure 570 setting page of multi-link master<\/p>\n<p>Step 3: Planning 6\u3010Numeric Input\/Display\u3011objects on the master screen,\u3010Monitor Address\u3011set as @0:R0 ~ @0:R5.<\/p>\n<p>Step 4: build a new project of the slave,\u3010Interface Type\u3011choose multi-link slave(serial),\u3010Destination Link Type\u3011choose serial,\u3010Port\u3011choose COM3(COM3 RS485 of the P5043N) and link with the multi-link slave,\u3010Baud Rate\u3011choose 115200,\u3010Total Stations\u3011choose 1, figure as shown belown.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\511.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-29\/p5hmi-fvd-en-29-010.jpg\" \/><\/p>\n<p>Figure 571 setting page of multi-link slave<\/p>\n<p>Step 5: Planning 6\u3010Numeric Input\/Display\u3011objects on the master screen,\u3010Monitor Address\u3011set as @1:R0 ~ @1:R5.<\/p>\n<p>Step 6: Download the project to master and slave HMI, and link with the FATEK PLC master and master COM4(RS485) and slave COM3(RS485), input the value in master and the slave will synchronize update, or input the value in slave and the master will synchronize update.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3010Multi-Link\u3011function is to build multi-link master on F [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3371","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3371","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3371"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3371\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3371"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3371"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3371"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}