{"id":3372,"date":"2026-11-17T18:43:16","date_gmt":"2026-11-17T10:43:16","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-30\/"},"modified":"2026-11-17T18:43:16","modified_gmt":"2026-11-17T10:43:16","slug":"p5hmi-fvd-en-30","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/p5hmi-fvd-en-30\/","title":{"rendered":"Chapter 30 SearchReplace"},"content":{"rendered":"<h2>30. Search\/Replace<\/h2>\n<p>The\u3010Search\/Replace\u3011function is to provide designers with more efficient and time-saving tools for planning projects. For example, when the designer is planning a project, it is uncertain whether those PLC addresses or internal addresses of the HMI are used , or on which items or functions to use, can search through the entire project, screen or function to search for the desired address, avoid using the same address and affect the function of the operation; Or in a project that has already been planned, it is hoped that the address of the modified part will have multiple consecutive addresses. At this time, you can also use this auxiliary function to modify batches at once, instead of spending a huge amount of time and effort, opening items one by one to make changes, etc.<\/p>\n<h3>30.1 The Use of Search\/Replace<\/h3>\n<p>This section explains how to use the\u3010Search\/Replace\u3011feature and how to set the window.\u3010Search\/Replace\u3011function can click on the <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-001.png\" \/> icon in the status bar on any screen, or press the\u3010Ctrl+F\u3011key on the keyboard to open\u3010Search\/Replace\u3011function dialog window<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-002.jpg\" \/><\/p>\n<p>Figure 572 status bar<\/p>\n<p>The options for opening the\u3010Search\/Replace\u3011function dialog window are shown in the following figure. The meaning of each option is as follows:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-003.jpg\" \/><\/p>\n<p>Figure 573\u3010Search\/Replace\u3011function window<\/p>\n<p>Table 318\u3010Search\/Replace\u3011function properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Descriptions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Target\u3011<\/p>\n<\/td>\n<td>\n<p>To search for or replace the address or text used in the project.<\/p>\n<p>\u3010Address\u3011<\/p>\n<p>Choose to search or replace the address used in the project.<\/p>\n<p>\u3010Text\u3011<\/p>\n<p>Choose to search or replace text used in a project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Data Type\u3011<\/p>\n<\/td>\n<td>\n<p>The address to be searched for or replaced in the project is\u3010Bit\u3011or\u3010Word\u3011, etc.<\/p>\n<p>When the target is selected as\u3010Address\u3011this option will be displayed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Range\u3011<\/p>\n<\/td>\n<td>\n<p>Select the range of addresses to search for or replace in the project.<\/p>\n<p>When the target is selected as\u3010Address\u3011this option will be displayed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Case Sensitive\u3011<\/p>\n<\/td>\n<td>\n<p>Select whether to search for or replace the text in the project is case-sensitive.<\/p>\n<p>When the target is selected as\u3010Text\u3011this option will be displayed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Whole Words Only\u3011<\/p>\n<\/td>\n<td>\n<p>Select if you want to search or replace the text in the project if all text is the same.<\/p>\n<p>When the target is selected as\u3010Text\u3011this option will be displayed.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Search for\u3011<\/p>\n<\/td>\n<td>\n<p>Fill in the address or text to be searched. When\u3010Range\u3011is checked, you can set the start address and end address.<\/p>\n<p>If there is an error in the search address or text, the following figure shows the designer.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\t292_1.JPG\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-004.jpg\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Replace with\u3011<\/p>\n<\/td>\n<td>\n<p>Fill in the address or text to be replaced. When\u3010Range\u3011is checked, you can set the start address and end address.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Scope\u3011<\/p>\n<\/td>\n<td>\n<p>You can check the range you want to search for or replace, including\u3010Whole Project\u3011,\u3010Current Screen\u3011,\u3010All Screens\u3011,\u3010Unit Setting\u3011,\u3010Links\u3011,\u3010Servers\u3011,\u3010Security\u3011,\u3010Data Log\u3011,\u3010Alarm\u3011,\u3010Recipe\u3011,\u3010Operation Log\u3011,\u3010Schedule\u3011,\u3010Data Transfer\u3011,\u3010Script\u3011,\u3010Tag Library\u3011and\u3010Text Library\u3011, etc. When the target is selected as\u3010Text\u3011, the\u3010Script\u3011option will not provide selection. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Close after search or replace\u3011<\/p>\n<\/td>\n<td>\n<p>Close the window after search or replace.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Search\u3011<\/p>\n<\/td>\n<td>\n<p>Press to execute searching the address or text used in the project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Replace All\u3011<\/p>\n<\/td>\n<td>\n<p>Press to execute replacement address or text used in the project.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>30.2 The Result of Search\/Replace<\/h3>\n<p>Search results using the\u3010Search\/Replace\u3011function will be displayed in the Search\/Replace results window, as shown in the following Figure 572.<\/p>\n<p>The options for the\u3010Search\/Replace\u3011results window are shown in Figure 572 below, where the options are as follows:<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\514.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-005.jpg\" \/><\/p>\n<p>Figure 574\u3010Search\/Replace\u3011result function window<\/p>\n<p>Table 319\u3010Search\/Replace\u3011function properties setting<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Properties<\/p>\n<\/td>\n<td>\n<p>Description<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Search for\u3011<\/p>\n<\/td>\n<td>\n<p>This field only provides an address for execute search function cannot be entered.<\/p>\n<p>\u3010Search Again\u3011<\/p>\n<p>Search again for the address or text used in the project.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Replace with\u3011<\/p>\n<\/td>\n<td>\n<p>This field can be entered to replace the address or text in the project.<\/p>\n<p>\u3010Replace\u3011<\/p>\n<p>Replace the address or text in the project with the set address or text.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Search Result\u3011<\/p>\n<\/td>\n<td>\n<p>Display the searched address and text, you can use the check box to select the item you want to replace. Double-click the left mouse button on the searched object to display the screen where the object is located in the window area. At the same time, the object properties will be displayed for the designer to edit. The content will contain the following fields.<\/p>\n<p>\u3010Name\u3011<\/p>\n<p>Display the name of the searched object and the screen where the object is located.<\/p>\n<p>\u3010Search\u3011<\/p>\n<p>The searched address.<\/p>\n<p>\u3010Replace\u3011<\/p>\n<p>The replaced address.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>In addition, on the\u3010View\u3011tab of the FvDesigner ribbon, click\u3010Search\/Replace\u3011to also enable or disable the\u3010Search\/Replace\u3011result window.<\/p>\n<p><img decoding=\"async\" alt=\"C:\\Users\\chien yu\\Desktop\\fv 1.5 pic\\515.jpg\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/p5hmi-fvd-en-30\/p5hmi-fvd-en-30-006.jpg\" \/><\/p>\n<p>Figure 575\u3010Search\/Replace\u3011option in\u3010View\u3011<\/p>\n","protected":false},"excerpt":{"rendered":"<p>30. Search\/Replace The\u3010Search\/Replace\u3011function is to pr [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[57],"tags":[],"class_list":["post-3372","post","type-post","status-publish","format-standard","hentry","category-en-p5hmi-fvd"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3372","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3372"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3372\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3372"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3372"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}