{"id":3379,"date":"2026-11-17T21:05:06","date_gmt":"2026-11-17T13:05:06","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-hw-en-102\/"},"modified":"2026-11-17T21:12:56","modified_gmt":"2026-11-17T13:12:56","slug":"fbs-hw-en-102","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-hw-en-102\/","title":{"rendered":"Appendix 2 PWMDA Analog Output Module"},"content":{"rendered":"<p>Although FBs Series main unit has been provide analog output module, but allow for the customer who only one point analog output demand. FATEK Automation created the simple and easy analog output module(PWMDA) which to fit various application.<\/p>\n<p>\t FBs PWMDA Using the theorem of pulse width modulation, cooperate to peripheral output circuit, and then it can transform the different width of digital signal pulse to corresponding analog output voltage(0\uff5e10V). <\/p>\n<p> If you want to use PWMDA then you must purchase the PWMDA component form FATEK Automation, and replace to transistor output (the step of replace output component, please refer to chapter 1.1). After finish the component change procedure. Using high speed pulse width modulation instruction (FUN139) to send analog voltage. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p> 1.1 PWMDA Component Installation <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\tFBs-PLC PWMDA component only can be installed in high speed output(Y0\u3001Y2..), because it must match up with FUN139. The shape of PWMDA component and change method shows in below<strong> :<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-001.jpg\" \/><\/p>\n<p>1. If the output component(Y0) were TR(J)-H originally, then remove TR(J)-H directly. And replace to PWMDA component \tto finish change procedure. <\/p>\n<p>2. If the output component(Y0) were Relay, TR(J), or TR(J)-M originally, then you not only to remove driver transistor \t(DTC123E), but also to install a SMD resistance(100\u2126) in Y0R position. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-002.jpg\" \/><\/p>\n<p> Opening the cover of PLC, take I\/O board out and turn it over <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-003.jpg\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-004.png\" \/><\/p>\n<p>Removed drive transistor \tInstalled the SMD <\/p>\n<p>DTC123E. \tresistance(100\u2126) in Y0R <\/p>\n<p>position.<\/p>\n<p> Before PWMDA component change <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-005.jpg\" \/><\/p>\n<p> After PWMDA component change <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 Caution<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> When Y0 has been finished PWMDA component change, then Y1 won\u2019t be used anymore (because they used the same common ground). After component changed, please pasting the serials number stickers in correct position for recognized easily. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-006.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-007.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-008.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-009.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-010.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-011.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-012.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-013.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-014.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-015.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-016.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-017.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-018.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-019.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-020.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-021.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-022.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-023.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-024.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-025.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-026.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-027.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-028.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-029.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-030.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-031.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-032.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-033.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-034.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-035.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-036.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-037.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-038.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-039.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-040.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-041.png\" \/><\/p>\n<p> 1.2 Specifications of PWMDA <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Items <\/p>\n<\/td>\n<td>\n<p> Specifications <\/p>\n<\/td>\n<td>\n<p> Remark <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Span of Analog Output <\/p>\n<\/td>\n<td>\n<p> DC 0\uff5e10V <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Digital output value <\/p>\n<\/td>\n<td>\n<p> 0\uff5e1000 <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Resolution <\/p>\n<\/td>\n<td>\n<p> 10mV(10V\/1000) <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Output resistance <\/p>\n<\/td>\n<td>\n<p> 1K <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Minimum loading\uff08\u226510V output\uff09<\/p>\n<\/td>\n<td>\n<p> 5.2K <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>D\/A conversion time <\/p>\n<\/td>\n<td>\n<p>\uff1c50mS <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Performance curve <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Analog Output<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p>879 1000<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>11.41V<\/p>\n<p>10V<\/p>\n<\/td>\n<td>\n<p>Digital Output Value<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p> Application Example <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-042.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-043.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-044.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-045.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-046.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>max.<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>24V OUT X0<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X2 X1<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X4 X3<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X5<\/strong><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><strong>X6<\/strong><\/p>\n<p>0<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><strong>X7 <\/strong><br \/>I 2 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><strong>X8<\/strong><\/p>\n<p>2 3<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X9<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X10<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X11<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X12<\/strong><\/p>\n<\/td>\n<td rowspan=\"4\">\n<p><strong>X13<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p><strong>400mA<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><strong>S\/S<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>5 6 <\/p>\n<\/td>\n<td>\n<p>6 7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8<\/p>\n<\/td>\n<td>\n<p>9 I<\/p>\n<\/td>\n<td>\n<p>0 I I<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>I2I3<\/p>\n<p><strong>INX <\/strong>( )<\/p>\n<p><strong>POW<\/strong><\/p>\n<p><strong>PROGRAMMABLE RUN<\/strong><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><strong>CONTROLLER<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>TX<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>RX<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>ERR<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p><strong>IN<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><strong>AC100~240V<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><strong>Y1<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><strong>PORT0<\/strong><\/p>\n<p><strong>Y2 Y4<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><strong>4<\/strong><\/p>\n<\/td>\n<td>\n<p>0<\/p>\n<\/td>\n<td>\n<p><strong>OUT <\/strong>I 2<\/p>\n<\/td>\n<td>\n<p>() <strong>Y<\/strong><\/p>\n<p>3<\/p>\n<\/td>\n<td rowspan=\"3\"><\/td>\n<td rowspan=\"3\">\n<p><strong>Y8<\/strong><\/p>\n<\/td>\n<td rowspan=\"3\"><\/td>\n<td rowspan=\"3\">\n<p><strong>SINK<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4<\/p>\n<\/td>\n<td>\n<p>5 6<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>7<\/p>\n<p><strong>Y6<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8 <br \/><strong>Y5<\/strong><\/p>\n<\/td>\n<td>\n<p>9<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><strong>C0 Y0 C2 Y3 C4 C6 Y7 Y9 SRCE<\/strong><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-047.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-048.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-049.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-050.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-051.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-052.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-053.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-054.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-055.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-056.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-057.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-058.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-059.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-060.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-061.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-062.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-063.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-064.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-065.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-066.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-067.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-068.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-069.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-070.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-071.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-072.png\" \/><\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-073.png\" \/><\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-074.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-075.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-076.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Pw <strong>:<\/strong> High speed pulse width modulation (pulse width modulation \u00c6analog voltage) output point(0=Y0, 1=Y2,\u2026) Op <strong>:<\/strong> Output polarity\uff1b= 0\uff1aDigital output value = 0, Vo=0V\uff1bDigital output value = 1000, Vo=10V. <br \/>\t= 1\uff1aDigital output value = 0, Vo=10V\uff1bDigital output value =1000, Vo=0V. <\/p>\n<p>Rs<strong> :<\/strong> Resolution\uff1b1=1\/1000 (0.1%)\u3002<\/p>\n<p>WR<strong> :<\/strong> Working register, it can\u2019t repeat in use. <\/p>\n<p>\u203b For detail illustration of FUN139, please refer to FBs user\u2019s manual I(Instruction Chapter). <\/p>\n<p> PWMDA hardware diagram &amp; resolution adjustment indication\uff1a<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-077.png\" \/><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-078.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-079.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-080.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-081.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-082.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-083.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> PWMDA hardware diagram  <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-084.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-085.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-086.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-087.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-088.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-089.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-090.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-091.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-092.png\" \/><\/p>\n<p>\u25cf Adjust through hardware <strong>:<\/strong> Firstly setting digital output value as 1000, then to adjust parallel resistance(Rv) to make Vo \t= 10V.(see curve A in below chart). <\/p>\n<p>\u25cf Adjust through software <strong>:<\/strong> Firstly setting digital output value as 1000. If Vo\u2265 10V then to reduce digital output value until \tVo = 10V(see curve B in below chart). <\/p>\n<p>Rin=\u221e. When digital output value around 879, Vo=10V, <br \/>resolution = 11.41mV. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-093.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-094.png\" \/><\/p>\n<\/td>\n<td>\n<p>Adjusting the parallel resistance Rv to make Vo=10V when digital <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>output value = 1000. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-hw-en-102\/fbs-hw-en-102-095.png\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Although FBs Series main unit has been provide analog o [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[33],"tags":[],"class_list":["post-3379","post","type-post","status-publish","format-standard","hentry","category-en-fbs-hw"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3379"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3379\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3379"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3379"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}