{"id":3437,"date":"2026-11-17T21:35:37","date_gmt":"2026-11-17T13:35:37","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-ins-en-103\/"},"modified":"2026-11-17T21:35:37","modified_gmt":"2026-11-17T13:35:37","slug":"fbs-ins-en-103","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-ins-en-103\/","title":{"rendered":"Appendix 1 FB-DAP Simple Human Machine Interface"},"content":{"rendered":"<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-001.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-002.png\" \/><\/p>\n<p>In addition to timer, counter, register, and contact data access function, the date setter of FB-DAP can connect to many others for alarm message display, self-defined buttons, wireless card reading, and the like simple human-machine (HM) functions. <\/p>\n<p> FB-DAP Simple HM <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"8\">\n<p>\tModel Spec. <\/p>\n<p>Display <br \/>Button <br \/>Wireless Card reading Power supply <br \/>Current consumption Com. Interface <br \/>Service points <br \/>connected <br \/>PLC Com. Port <br \/>connected <br \/>General feature <br \/>Special feature <br \/>Card writing feature <\/p>\n<\/td>\n<td>\n<p>FB-DAP-A(R) <\/p>\n<\/td>\n<td>\n<p>FB-DAP-B(R) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>LCD (English version), 2-line\u00d716-character, LED backlight 20-key (4\u00d75) <br \/>\u2212AR and(BR only\uff0cdistance 12\uff5e18cm <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5V <\/p>\n<\/td>\n<td>\n<p>24V <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>100mA (120mA) <\/p>\n<\/td>\n<td>\n<p>41mA (48mA) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>HCMOS <\/p>\n<\/td>\n<td>\n<p>RS-485 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Single set <\/p>\n<\/td>\n<td>\n<p>Max. 16-set connected <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>port 0 <\/p>\n<\/td>\n<td>\n<p>port 0,1,2   (In which port 0 and 1 needed to be converted as RS-485) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Timing\/counting\u3001register\u3001contact access(write protected for each) Alarm\u3001message display\u3001self-definition of special speed keys Order for machine types with special numbers to us is required <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u203b PLC\u2019s MA\u3001MU type machines can be connected to FB-DAP-B(R) only through FB-485 switch. <\/p>\n<p> Wireless sensing card <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"4\">\n<p>\tModel Spec. <\/p>\n<p>Memory <br \/>Operation temp. <\/p>\n<p>Power supply <\/p>\n<p>Sensing distance Number of writing Size (mm) <br \/>Weight (Gram) <\/p>\n<\/td>\n<td>\n<p>CARD-1 <\/p>\n<\/td>\n<td>\n<p>CARD-2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>64bits with Cyclic Redundancy Check (CRC) on data \u221225\u00b0C\uff5e50\u00b0C (conforming to ISO7810) <\/p>\n<p>Battery not required (power supplied from wireless electric waves released by an \u2212AR\/\u2212BR card-reading module) <\/p>\n<p>12cm\uff5e18cm(from FB-DAP front) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>unwritable(uncopiable\uff0cexclusively) <\/p>\n<\/td>\n<td>\n<p>10000 times at least <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>86\u00d754\u00d713 <br \/>12 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-003.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-004.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-005.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p> 1.1Profile <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>112<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>6.5<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>7<\/p>\n<\/td>\n<td rowspan=\"7\">\n<p>T<\/p>\n<\/td>\n<td rowspan=\"5\">\n<p>X<\/p>\n<\/td>\n<td colspan=\"6\">\n<p>98<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>7<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>30<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>148<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>Back<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>8<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>\u5916\u5f91 4\u03c8\u00d74   \u57cb\u87ba\u5e3d<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>118.45<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>Lateral<\/p>\n<\/td>\n<td rowspan=\"16\">\n<p>148<\/p>\n<\/td>\n<td>\n<p>14.8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"15\">\n<p>Front<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>FB-DAP<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>DATA ACCESS PANEL<\/p>\n<\/td>\n<td rowspan=\"15\">\n<p>1.5<\/p>\n<\/td>\n<td rowspan=\"15\">\n<p>22.43<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">\n<p>FATEK<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>7<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>+<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"3\">\n<p>8<\/p>\n<\/td>\n<td>\n<p>ON \/ OFF<\/p>\n<\/td>\n<td>\n<p>FUN<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>9<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>CLEAR<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>Y<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>E<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>F<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>ADR \/ DOC<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>C<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>4<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>5<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>6<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>M<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>A<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>B<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>DEC \/ HEX<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>D<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>1<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>2<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p>3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p>S<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>W<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>CV \/ PV<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>0<\/p>\n<\/td>\n<td colspan=\"3\">\n<p>SHIFT<\/p>\n<\/td>\n<td>\n<p>ENTER<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>14.75<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>102.5<\/p>\n<\/td>\n<td>\n<p>4.75<\/p>\n<\/td>\n<td>\n<p>12<\/p>\n<\/td>\n<td>\n<p>17.6<\/p>\n<\/td>\n<td>\n<p>9.9<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> 1.2Important points before operation <\/p>\n<p>1\u3001 FB-DAP possesses a function to return to the operation mode (general data setter and self-definition 8\/16 speed keys) before power failure and each DAP can be place in a different mode when connecting many sets. <\/p>\n<p>2\u3001 When operating FB-DAP\uff0cD2944\uff5eD3071 register of PLC will be used as the systematic architecture zone (in which data set by all the FUN functions can be stored except item 11) , the user shall avoid this zone. <\/p>\n<p>3\u3001 Any communication port, once converted to a RS-485 interface (port 2 is itself a RS-485 interface), can be connected to a maximum of 16 FB-DAP-B(R) sets. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>PLC port0<\/p>\n<\/td>\n<td>\n<p>FB-485P0 switch head<\/p>\n<\/td>\n<td>\n<p>RS-485 interface<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-006.png\" \/><\/p>\n<\/td>\n<td>\n<p>Only thus so the FB-DAPB (R) can <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>(HCMOS)<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>FB-485 switch <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>RS-485 interface<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>be connected to. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PLC port1<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>(RS-232)<\/p>\n<p>4\u3001 When PLC is connected with FB-DAP-B(R)\uff0cthe service point numbers of PLC are limited to a range of 1~32. <\/p>\n<p>5\u3001 Parameters for the connection between PLC and FB-DAP-B(R)(DAP automatic detection Baud Rate 9600 \/ 19200 \/ 38400) <\/p>\n<p>port0\u30011\u30012\uff1a9600 \/ 19200 \/ 38400\u3001Even\u30017Data bits\u30011Stop bit <br \/>\tex\uff1aR4158=5521H, i.e. port2 being 9600\uff1bR4158=5523H, i.e. port2 being 38400. <\/p>\n<p>6\u3001 When many sets of DAP are connected, if any two or more have the same service point number, then DAP will <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>request for number change, which can be done by only entering\u301d<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-007.png\" \/><\/p>\n<\/td>\n<td>\n<p>\u301e\u5373\u53ef\u3002<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>7\u3001 The transmission line of the RS-485 interface must use a twisted pair with a shielded cover on the outer layer. Please refer to chapter 12-5 in the Operation Manual II for other important points. <\/p>\n<p>8\u3001 The scanning time of PLC will affect the update time of DAP. <\/p>\n<p>9\u3001 The OS of FB-DAPB(R) shall be new V2.00 above PCB so that multiple sets can be connected. Press <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-008.png\" \/> then the OS version is displayed.<\/p>\n<p>10\u3001 When PROLADDER(or FP07) and DAP are connected to the same set of  PLC, to change the program through PROLADDER is not allowed; if so, the timer information displayed by DAP won\u2019t be correct (In this <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-009.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-010.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-011.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-012.png\" \/><\/p>\n<p>case, the DAP shall be reset). <\/p>\n<p>11\u3001 Versions after the OS V3.15 (including) of FP-07 can be aimed for DOCs in 16 words of contacts, registers. <\/p>\n<p> 1.3The Main Functions of FB-DAP <\/p>\n<p>The main functions of FB-DAP can be categorized as\uff1a setter functions of general information, FUN functions of parameter setting, wireless card reading, and message display function. The details of the functions will be introduced in the following sections. <\/p>\n<p> 1.4Setter Functions of General Information <\/p>\n<p>FB-DAP can be used as a \u301dTC setter\u301eas well as the access to registers (R\u3001D\u3001W) and  contacts (X\u3001Y\u3001M\u3001S). In the FUN functions in the following sections, it can also be used as write-protect with T\u3001C\u3001R\u3001D\u3001X\u3001Y\u3001M\u3001S. There are two measures to monitor information: ADR (general addresses) and DOC monitoring. The latter shall make DOC compilation (16 words in English, symbols, numbers) in advance through Proladder or FP07 for T, C, register R\/D and contacts so the DOC can be displayed. <\/p>\n<p>1\u3001 ADR Monitoring <\/p>\n<p>A. Timer and Counter Monitoring <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>\u3010Pressing Keys\u3011\uff1a<\/p>\n<\/td>\n<td colspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-013.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>T or C number <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>Cursor position <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-014.png\" \/><\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u2193<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>\u2022  \u2022 \u2022\u2022\u2022\u2022 \u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Set value <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>\u2022\u2022  \u2022\u2022\u2022 \u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Current value <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2191<\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u2191<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Status <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>FB-DAP automatic detecting a decimal point position <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>B. Registers (R\u3001D\u3001DR\u3001DD\u3001WX\u3001WY\u3001WM\u3001WS) and contacts (X\u3001Y\u3001M\u3001S) monitoring <\/p>\n<p>\u3010Monitored range\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Type <\/p>\n<\/td>\n<td>\n<p>T <\/p>\n<\/td>\n<td>\n<p>C <\/p>\n<\/td>\n<td>\n<p>D <\/p>\n<\/td>\n<td>\n<p>R <\/p>\n<\/td>\n<td>\n<p>DD<\/p>\n<\/td>\n<td>\n<p>DR<\/p>\n<\/td>\n<td>\n<p>WX<\/p>\n<\/td>\n<td>\n<p>WY<\/p>\n<\/td>\n<td>\n<p>WM<\/p>\n<\/td>\n<td>\n<p>WS<\/p>\n<\/td>\n<td>\n<p>X<\/p>\n<\/td>\n<td>\n<p>Y<\/p>\n<\/td>\n<td>\n<p>M<\/p>\n<\/td>\n<td>\n<p>S<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Range <\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>255<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>255 <\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>2943<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>8071<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>2492<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>8070<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>240 <\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>240 <\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>1984<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>984<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>255<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>255<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>2001<\/p>\n<\/td>\n<td>\n<p>0 <br \/>| <br \/>999<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p>\u3010Pressing keys\u3011\uff1a<\/p>\n<\/td>\n<td colspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-015.png\" \/><\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>or<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>or<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>or<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>)<\/p>\n<\/td>\n<td rowspan=\"6\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-016.png\" \/><\/p>\n<\/td>\n<td rowspan=\"6\">\n<p>+<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>+ (<\/p>\n<\/td>\n<td>\n<p>or<\/p>\n<\/td>\n<td>\n<p>)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>+<\/p>\n<\/td>\n<td>\n<p>(<\/p>\n<\/td>\n<td>\n<p>or<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>(<\/p>\n<\/td>\n<td>\n<p>or<\/p>\n<\/td>\n<td>\n<p>or<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>Cursor position <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Value <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>\u2193<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u2193<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<p>\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td rowspan=\"2\"><\/td>\n<td>\n<p>\u2190 Item 1 <\/p>\n<\/td>\n<td rowspan=\"2\"><\/td>\n<td rowspan=\"2\"><\/td>\n<td rowspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2022 <\/p>\n<\/td>\n<td colspan=\"4\">\n<p>\u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Item 2 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2191<br \/>Status <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-017.png\" \/><\/p>\n<p>\u301dH\u301e indicates hexadecimal <br \/>\t\u2193<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"3\">\n<p>Note\uff1a1\u3001Pressing<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022 <br \/>\u2022\u2022<\/p>\n<\/td>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u2022\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2191<br \/>Y15 <\/p>\n<p>2\u3001<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u2191<br \/>Y0 <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-018.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u3001Pressing<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-019.png\" \/><\/p>\n<\/td>\n<td>\n<p> or <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-020.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>3\u3001For a monitored item value, input a new value directly and then press <br \/>\t can move the cursor up and down or switch between CV or PV. <\/p>\n<p> can decrease or increase the monitored item number. <\/p>\n<p>\t<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-021.png\" \/>. The status of the <br \/>\u203b WX\u3001WY\u3001WM\u3001WS can display one item only but each <\/p>\n<p>pressing status is available. <\/p>\n<p>contacts can be changed by pressing <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-022.png\" \/>. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4\u3001Pressing <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-023.png\" \/><\/p>\n<\/td>\n<td>\n<p> can change the means to display a value (either with decimal or hexadecimal <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>system). <\/p>\n<p>2\u3001 DOC monitoring <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u2022\u2022\u2022\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 DOC of T10 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Current value <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2191<br \/> Contact status <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"9\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<p>\u2022\u2022\u2022\u2022\u2022\u2022\u2022 <\/p>\n<\/td>\n<td>\n<p>\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Register DOC <\/p>\n<\/td>\n<td rowspan=\"3\"><\/td>\n<td rowspan=\"3\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\">\n<p>\u2022 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\u2022\u2022\u2022\u2022<\/p>\n<\/td>\n<td>\n<p>\u2190 Value <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\">\n<p>Note\uff1a1\u3001Pressing<\/p>\n<\/td>\n<td colspan=\"2\" rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-024.png\" \/><\/p>\n<\/td>\n<td colspan=\"3\" rowspan=\"2\">\n<p> can switch the monitoring of ADR and DOC. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-025.png\" \/><\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\">\n<p>2\u3001The display switch between CV (current value) and PV of the timer (counter) can use <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3\u3001<\/p>\n<\/td>\n<td colspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-026.png\" \/><\/p>\n<\/td>\n<td colspan=\"4\">\n<p> can be moved up or down to next monitored item with DOC. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>3\u3001 Speed monitoring FUN keys(FUN KEY 0\uff5e9, totaling 10 keys) <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u3010Pressing keys\u3011\uff1a<\/p>\n<\/td>\n<td>\n<p>+<\/p>\n<\/td>\n<td>\n<p>(<\/p>\n<\/td>\n<td>\n<p>\uff5e<\/p>\n<\/td>\n<td>\n<p>)   Direct display of a monitored item set by the client. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Note\uff1a1\u3001Items to be monitored can be set from the following \u201cFUN functions\u201d. <\/p>\n<p> 2\u3001Items to be monitored can be displayed with general or DOC means. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-027.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-028.png\" \/><\/p>\n<p> 1.5FUN Functions <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p> 1.5.1In and out of FUN functions <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u25a0 Enter FUN functions<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"26\">\n<p>Press            +        +<\/p>\n<\/td>\n<td rowspan=\"26\">\n<p>Press<\/p>\n<\/td>\n<td rowspan=\"10\">\n<p>\uff0a<\/p>\n<\/td>\n<td>\n<p>1\u3001PASSWORD OPEN<\/p>\n<\/td>\n<td>\n<p>(Password open)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2\u3001PASSWORD CLOSE<\/p>\n<\/td>\n<td>\n<p>(Password blocked)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3\u3001PASSWORD SET<\/p>\n<\/td>\n<td>\n<p>(Password setting)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4\u3001DEFINE FUN KEY<\/p>\n<\/td>\n<td>\n<p>(Self-define speed monitoring function key FUN KEY 0-9)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5\u3001DEFINE ALARM<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Self-define start address of content for display at an alarm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> ADDRESS<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6\u3001DEFINE SOFTKEY<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Self-define 8 special keys)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> (8-KEY)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7\u3001DEFINE SOFTKEY<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Enter into the modes of the 8 special keys)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> MODE (8-KEY)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<p>\uff0a<\/p>\n<\/td>\n<td>\n<p>8\u3001DEFINE SOFTKEY<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>(Self-define 16 special keys)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> (16-KEY)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>9\u3001ENTER SOFTKEY<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>(Enter into the modes of the 16 special keys)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> MODE(16-KEY)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cb<\/p>\n<\/td>\n<td>\n<p>10\u3001VOLUME<\/p>\n<\/td>\n<td>\n<p>(Adjust volume)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>\u25cb<\/p>\n<\/td>\n<td>\n<p>11\u3001SET DAP NO.<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Set DAP number(s) at multi-link)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>12\u3001MAX. DAP NO.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>(Set the max. DAP numbers on network (1-16) at multi-link)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> ON NETWORK(1~16)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cb<\/p>\n<\/td>\n<td>\n<p>13\u3001WRITE PROTECT<\/p>\n<\/td>\n<td>\n<p>(Data write-in protection)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u25cb<\/p>\n<\/td>\n<td>\n<p>14\u3001RF CARD MODE<\/p>\n<\/td>\n<td>\n<p>(RF card mode selection)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>\u25cb<\/p>\n<\/td>\n<td>\n<p>15\u3001RF CARD<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Start address of a RF card number storage)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> START ADDR.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>\uff0a<\/p>\n<\/td>\n<td>\n<p>16\u3001ENABLE<\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>(Corresponding special contacts of ENABLE keys)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p> KEYS MAPPING<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0a\uff1aIndicates when multiple DAPs are connected, each DAP can be set respectively. <\/p>\n<p>\u25cb\uff1aIndicates when multiple DAPs are connected, the information set by one of them is not available for use until PLC is reset.<\/p>\n<p>\u25a0 Exit  of FUN functions to general information setter functions.  Press \u2022\u2022\u2022\uff0b\u2022\u2022\u2022 \uff0b\u2022    \u2022\u2022            \uff0b<\/p>\n<p>Note\uff1a1\u3001When several DAPs are connected, information can be stored to PLC (D2944\uff5eD3071) if one of the DAP is set in <\/p>\n<p>all the FUN functions (except item 11). <\/p>\n<p>2\u3001After entering FUN 4~15, without password protection, all the FUN functions can be executed by only pressing <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-029.png\" \/>.  With password protection, it is required to pass it first before executing FUN functions. <\/p>\n<p>3\u3001If it is password-protected, FB-DAP will be set in a password protection status at each beginning of operation. <\/p>\n<p>4\u3001FUN items 1~9 can be entered with numeric keys directly and then go straight to that function. <\/p>\n<p>5\u3001After executing a item of FUN functions, if execution of other items is required, press the three keys <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-030.png\" \/><\/p>\n<\/td>\n<td>\n<p> again. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-031.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-032.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>1.5.2FUN function description <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>FUN 1\uff5e3\uff08password\uff09<\/p>\n<p>1\u3001 Password contains up to 4 digits\uff08unrelated to LADDER program\u2019s password\uff09. <\/p>\n<p>2\u3001 After the password is set, it will enter a password-locked status once it is started. <\/p>\n<p>3\u3001 After the password is locked, all the FUN functions are not available. <\/p>\n<p>FUN 4\uff08DEFINE FUN KEY\uff09\uff1aSelf-setting speed monitoring function keys <\/p>\n<p>4\u3001DEFINE FUN KEY <\/p>\n<p>\u3001<\/p>\n<p>1\u3001 There are ten self-setting speed monitoring function keys in total. <\/p>\n<p>2\u3001 All items available for monitoring can be defined in the ten function keys. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>3\u3001 Pressing <\/p>\n<\/td>\n<td>\n<p>+<\/p>\n<\/td>\n<td>\n<p> can select ADR or DOC. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>FUN 5\uff08DEFINE ALARM ADDRESS\uff09\uff1aThe address for display at self-setting an alarm. <\/p>\n<p>1. There are ten start addresses, that is, ten levels of alarm signals. <\/p>\n<p>2. All items available for monitoring can be defined in the said ten start addresses. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>3. Pressing <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-033.png\" \/><\/p>\n<\/td>\n<td>\n<p> can select ADR or DOC for display. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>4. Control measures of alarm signals for display are shown as follows\uff1a<\/p>\n<p>\u3010Corresponding list for control\u3011<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Alarm level <br \/>\uff08priority sequence\uff09<\/p>\n<\/td>\n<td>\n<p>Control contact<\/p>\n<\/td>\n<td>\n<p>Indication register<\/p>\n<\/td>\n<td>\n<p>Start address of the content displayed<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALARM 0 <\/p>\n<\/td>\n<td>\n<p>M1900 <\/p>\n<\/td>\n<td>\n<p>R3820 <\/p>\n<\/td>\n<td>\n<p>Client-defined <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALARM 1 <\/p>\n<\/td>\n<td>\n<p>M1901 <\/p>\n<\/td>\n<td>\n<p>R3821 <\/p>\n<\/td>\n<td>\n<p>Client-defined <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALARM 9 <\/p>\n<\/td>\n<td>\n<p>M1909 <\/p>\n<\/td>\n<td>\n<p>R3829 <\/p>\n<\/td>\n<td>\n<p>Client-defined <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3010Example\u3011Assume the start address of ALARM 0 displayed content to be R100, \tIf M1900=1 then the alarm address for display is R100 +\uff08R3820\uff09<\/p>\n<p>If R3820=0 \tDisplay address or DOC of R100 <\/p>\n<p>R3820=1 \tDisplay address or DOC of R101 <\/p>\n<p>R3820=2 \tDisplay address or DOC of R102 <\/p>\n<p>Note 1\uff1aWhen a multi-level alarm occurs, only the address or DOC with priority can be displayed. The \taddress or DOC of a sub level alarm will not be displayed until this alarm with priority is released. <\/p>\n<p>Note 2\uff1aTo display a DOC (message) with 16 digits above, the corresponding indication register (R3820\uff5e\tR3829) content can be changed anytime to reach this purpose. <\/p>\n<p>Note 3\uff1aM1911 can control whether to sound the alarm buzzer. If M1911=0 (preset), it shall be activated. <\/p>\n<p>FUN 6\uff08DEFINE SOFTKEY\uff0d8 KEYS\uff09\uff1aSelf-defining 8 soft keys <\/p>\n<p>FUN 7\uff08ENTER SOFTKEY MODE\uff0d8 KEYS\uff09\uff1aEnter 8 soft key mode <\/p>\n<p>1. Can self-define 8 soft keys\uff1a<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-034.png\" \/><\/p>\n<p>2. Definable range\uff1aR0\uff5eR3839\u3001D0\uff5eD2943\u3001M0\uff5eM1899. <\/p>\n<p>3. In defining M0\uff5eM1899, this key can be defined as one of the 5 modes. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Mode <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Definition <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Set <\/p>\n<\/td>\n<td>\n<p>\uff08S\uff09<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Set this contact to 1 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Reset <\/p>\n<\/td>\n<td>\n<p>\uff08R\uff09<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Set this contact to 0 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Moment <\/p>\n<\/td>\n<td>\n<p>\uff08M\uff09<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>1 in pressing, 0 in being released <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Inverse <\/p>\n<\/td>\n<td>\n<p>\uff08I\uff09<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Pressing once will have one inverse phase. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Monitor <\/p>\n<\/td>\n<td>\n<p>\uff08V\uff09<\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Monitor this contact <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u3010Example\u3011 Assume<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-035.png\" \/><\/p>\n<\/td>\n<td colspan=\"2\">\n<p>definition as R0, <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-036.png\" \/><\/p>\n<\/td>\n<td>\n<p>definition as M0 mode 0(Set). Once enter the 8 soft key <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>mode in function 7, <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>Then pressing <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-037.png\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>display address or DOC of R0. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-038.png\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>display  address or DOC of M0 and force M0 ON <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Note 1\uff1aAfter defining the 8 soft keys, once function 7 is executed, it will enter 8 soft key operation mode. <\/p>\n<p>And then the 8 soft keys will be executed according to function 6 definitions. <\/p>\n<p>Note 2\uff1a<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-039.png\" \/>\tboth are allowed out of definition, but the other keys will not be effected without <\/p>\n<p>definition. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Note 3\uff1aTo return to normal operation mode, press\u301d<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-040.png\" \/><\/p>\n<\/td>\n<td>\n<p>+\uff08D2972 content\uff09+<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-041.png\" \/><\/p>\n<\/td>\n<td>\n<p>\u301e, among which <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>D2972 content is from 0000\uff5e9999\uff084 digits required\uff09. <\/p>\n<p>FUN 8\uff08DEFINE SOFTKEY\uff0d16 KEYS\uff09\uff1aSelf-define 16 soft keys <\/p>\n<p>FUN 9\uff08ENTER SOFTKEY MODE\uff0d16 KEYS\uff09\uff1aEnter 16 soft key mode <\/p>\n<p>1. Available for defining 16 soft keys\uff1a<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-042.png\" \/><\/p>\n<p>2. Definable range\uff1aT0\uff5eT255\u3001C0\uff5eC199\u3001R0\uff5eR3839\u3001D0\uff5eD2943\u3001M0\uff5eM1899\u3002<\/p>\n<p>3. In defining M0\uff5eM1899, this key can be defined as one of the 5 modes and when a message is being <\/p>\n<p>displayed, if the key is pressed, the display will not be changed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Mode <\/p>\n<\/td>\n<td colspan=\"3\">\n<p>Definition <\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>0 <\/p>\n<\/td>\n<td>\n<p>Set <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\uff08S\uff09<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Set this contact to 1 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>Reset <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\uff08R\uff09<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Set this contact to 0 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>Moment <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\uff08M\uff09<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>1 in pressing, 0 in being released <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>Inverse <\/p>\n<\/td>\n<td>\n<p>\uff08I\uff09<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Pressing once will have one inverse phase. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>Monitor <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>\uff08V\uff09<\/p>\n<\/td>\n<td colspan=\"5\">\n<p>Monitor this contact <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">\n<p>4. When defined as T, C, R or D, the value change is by pressing<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-043.png\" \/><\/p>\n<\/td>\n<td>\n<p> or <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-044.png\" \/><\/p>\n<\/td>\n<td>\n<p> to make the corresponding <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>M1840\uff5eM1871 ON (the client is required to write a plus\/minus 1 program in the LADDER program) to achieve <\/p>\n<p>this purpose. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Soft <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>0 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>1 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>2 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>3 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>4 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>5 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>6 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>7 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>8 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>9 <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>T <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>C <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>D <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>R <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>SHIFT<\/p>\n<\/td>\n<td rowspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-045.png\" \/><\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>key<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>M1840M1841M1842M1843M1844M1845M1846M1847M1848M1849M1850M1851M1852M1853M1854M1855<\/p>\n<p>M1856M1857M1858M1859M1860M1861M1862M1863M1864M1865M1866M1867M1868M1869M1870M1871<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-046.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u3010Example\u3011Assume<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-047.png\" \/><\/p>\n<\/td>\n<td>\n<p> definition as R0, <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-048.png\" \/><\/p>\n<\/td>\n<td>\n<p> defined as M0 mode 1 (Reset). <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>After entering 16 soft key mode in function 9, <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Press <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-049.png\" \/><\/p>\n<\/td>\n<td>\n<p> Display the address or DOC of R0, and then pressing <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-050.png\" \/><\/p>\n<\/td>\n<td>\n<p>, its corresponding <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>M1850 will be ON; OFF after it is released. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-051.png\" \/>\t Display the address or DOC of M0 and force M0 OFF. <\/p>\n<p>Note 1\uff1aAfter the 16 soft keys are defined, once function 9 is executed, it will enter 16 soft key operation mode and then the 16 soft keys will be executed according to function 8 definition. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Note 2\uff1ato return to normal operation mode, press\u301d<\/p>\n<\/td>\n<td>\n<p>+ (<\/p>\n<\/td>\n<td>\n<p>+<\/p>\n<\/td>\n<td>\n<p>+<\/p>\n<\/td>\n<td>\n<p>+<\/p>\n<\/td>\n<td>\n<p>) +<\/p>\n<\/td>\n<td>\n<p>\u301e\u3002<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>FUN 11\uff08SET DAP NO.\uff09\uff1aWhen several sets are connected, set DAP number. <\/p>\n<p>After any communication of FB-PLC is converted to RS-485 interface (Among which port2 as such is a RS-485 interface), the FB-DAP-B(R) of the 16 sets can be connected. Each DAP shall need a unique number, 1~16 (but one of them must be number 1). This DAP is not related to PLC numbers, meaning the number can have the same PLC number. <\/p>\n<p>FUN 12\uff08MAX. DAP NO. ON NETWORK\uff09\uff1awhen several sets are connected, set the biggest DAP number on the Web. \t\uff08Max. 16 DAPs, preset 7\uff09<\/p>\n<p>In a connection of several sets, FB-PLC can be joined with new DAPs. But the more the DAP number, the longer the time to update information of each DAP. As a result, set the DAP number (the DAP number can not be bigger than this number) on the Web appropriately will decrease time for information to update. <\/p>\n<p>FUN 13\uff08WRITE PROTECT\uff09\uff1aInformation write in <\/p>\n<p>\tAimed for monitored items (T, C, R, D, Y, M, S), set the information in write-in protection separately. Just fill in the corresponding place with 1, and then the item is write-in protected and can be read values only. <\/p>\n<p>FUN 14\uff08RF CARD MODE\uff09\uff1aWireless card reading options <\/p>\n<p>MODE=\u301d0\u301e When reading a RF card, it will display whether this card is OK or Error. When the RF card is out of sensing distance, it will pop up \u301dNEXT\u301e, indicating another RF card is available now. <\/p>\n<p>MODE=\u301d1\u301e\tonce a RF card is read, it will beep once and will not display any information so the <\/p>\n<p>sensing speed can be faster. But when many DAPs are connected, this mode will increase <\/p>\n<p>by about 60mS to each set for monitored item information. <\/p>\n<p>FUN 15\uff08RF CARD START ADDR.\uff09\uff1aStart addresses storing the wireless RF card numbers <\/p>\n<p>\tStore a card number\u2019s address can be set through the function, ranging from D0~D2860 (preset to D2860). Please refer to the Wireless Card Reading Functions in 1.6 for detailed description. <\/p>\n<p>FUN 16\uff08ENABLE KEYS MAPPING\uff09\uff1aCorresponding special contact of Enable key <\/p>\n<p>After this function is set to \u301dEnable\u301e and enter SOFTKEYMODE\uff088KEYS and 16KEYS\uff09, pressing a definable soft key will force ON some contact of a corresponding contact under its number and the other contacts become OFF. When set to \u201cDisable\u201d, the corresponding special contact of this DAP will not be effected. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-052.png\" \/><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-053.png\" \/><\/p>\n<p>The following is corresponding special contacts to different DAP keys when in 16 KEYS MODE: <\/p>\n<p>KEY<\/p>\n<p>T C \tD \tR 7 \t4 1 0 \t8 \t5 \t2 \tSHIFT \t9 \t6 \t3 <\/p>\n<p>No. \t\uff08\u2191\uff09\t\uff08\u2193\uff09<\/p>\n<p>1 \tM1784M1785M1786M1787M1788M1789M1790M1791M1792M1793M1794M1795M1796M1797M1798M1799<\/p>\n<p>2 \tM1768M1769M1770M1771M1772M1773M1774M1775M1776M1777M1778M1779M1780M1781M1782M1783<\/p>\n<p>3 \tM1752M1753M1754M1755M1756M1757M1758M1759M1760M1761M1762M1763M1764M1765M1766M1767<\/p>\n<p>4 \tM1736M1737M1738M1739M1740M1741M1742M1743M1744M1745M1746M1747M1748M1749M1750M1751<\/p>\n<p>5 \tM1720M1721M1722M1723M1724M1725M1726M1727M1728M1729M1730M1731M1732M1733M1734M1735<\/p>\n<p>6 \tM1704M1705M1706M1707M1708M1709M1710M1711M1712M1713M1714M1715M1716M1717M1718M1719<\/p>\n<p>7 \tM1688M1689M1690M1691M1692M1693M1694M1695M1696M1697M1698M1699M1700M1701M1702M1703<\/p>\n<p>8 \tM1672M1673M1674M1675M1676M1677M1678M1679M1680M1681M1682M1683M1684M1685M1686M1687<\/p>\n<p>9 \tM1656M1657M1658M1659M1660M1661M1662M1663M1664M1665M1666M1667M1668M1669M1670M1671<\/p>\n<p>10 \tM1640M1641M1642M1643M1644M1645M1646M1647M1648M1649M1650M1651M1652M1653M1654M1655<\/p>\n<p>11 \tM1624M1625M1626M1627M1628M1629M1630M1631M1632M1633M1634M1635M1636M1637M1638M1639<\/p>\n<p>12 \tM1608M1609M1610M1611M1612M1613M1614M1615M1616M1617M1618M1619M1620M1621M1622M1623<\/p>\n<p>13 \tM1592M1593M1594M1595M1596M1597M1598M1599M1600M1601M1602M1603M1604M1605M1606M1607<\/p>\n<p>14 \tM1576M1577M1578M1579M1580M1581M1582M1583M1584M1585M1586M1587M1588M1589M1590M1591<\/p>\n<p>15 \tM1560M1561M1562M1563M1564M1565M1566M1567M1568M1569M1570M1571M1572M1573M1574M1575<\/p>\n<p>16 \tM1544M1545M1546M1547M1548M1549M1550M1551M1552M1553M1554M1555M1556M1557M1558M1559<\/p>\n<p>In 8KEYS MODE, only 8 keys\t\u3001\t\u3001\u3001\t\u3001\t\u3001\t\u3001\t\u3001\tare effective, i.e. <\/p>\n<p>number keys ineffective.  And<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-054.png\" \/> take the positions of<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-055.png\" \/>and<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-056.png\" \/>, but it must be when both <\/p>\n<p>keys are defined as soft keys so that the corresponding special contacts are effective. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u3008Example\u3009 No.2\uff1aPressing <\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-057.png\" \/><\/p>\n<\/td>\n<td>\n<p>, \uff2d1768 is ON and M1769\uff5eM1783 OFF. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>No. 5\uff1aPressing<\/p>\n<\/td>\n<td>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-058.png\" \/><\/p>\n<\/td>\n<td>\n<p>, \uff2d1722 is ON and other contacts M1720\uff5eM1735 OFF. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> 1.6Wireless card reading functions <\/p>\n<p> An applicable RF card is an exclusive read-only card (RF-CARD-1) or readable\/writable card \uff08RF-CARD-2\uff09, <\/p>\n<p>in which the card number of the read-only card is unique ( with 16 0~F digits), not repeatable and copyable. <\/p>\n<p>And card numbers read by FB-DAP-AR(BR) shall be encoded with high security. <\/p>\n<p> The sensing distance of a RF card generally is 12\uff5e18cm, but shall be kept away from electromagnetic <\/p>\n<p>wave interference source or high voltage power line. <\/p>\n<p> Readable\/Writable cards \uff08RF-CARD-2\uff09can use Fatek\u2019s FB-DAP-W in special sequence numbers to write in <\/p>\n<p>card numbers. The card numbers are all encoded and relate to machine sequence numbers (the first 4 <\/p>\n<p>codes are the machine\u2019s sequence number, the last 12 codes defined by the client). Only through Fatek\u2019s <\/p>\n<p>FB-DAP-A(B)R can a correct numbers be read. Under FUN function 17, FB-DAP-W can be input 12 0~F <\/p>\n<p>digits or use \t<img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-059.png\" \/> to change the card number. Finally, only place the distance of RF-CARD-2 <\/p>\n<p>within FB-DAP-W 12cm and then press <img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-060.png\" \/>, so that the card number can be written into RF-CARD-2. <\/p>\n<p>Locations and application of the card number storage <\/p>\n<p>FB-DAP saves RF card numbers within sensing distance into two places in PLC. The places and application are described as follows: <\/p>\n<p>4\u3001Fixed in R3835\uff5eR3839\uff08totaling 5 registers\uff09\uff1aDuring operation, M1910 shall be controlled. <\/p>\n<p>Card number <br \/>format <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>R3835<\/p>\n<\/td>\n<td rowspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>N1<\/p>\n<\/td>\n<td>\n<p>N2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td>\n<p>N1\uff1aDAP number 1\uff5e16\uff08i.e. 1H\uff5e10H\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R3836<\/p>\n<\/td>\n<td>\n<p>N2\uff1a52H\uff08R\uff1aread-only card\uff09 or 57H\uff08W\uff1areadable\/writable card\uff09<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R3837<\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>R3836\uff5eR3839 store 16 0~F card numbers <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R3838<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>R3839<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Application\uff1a<br \/>Only in monitoring (or8\/16 soft keys) mode (non-FUN functions) and the RF card in sensing distance, FB-DAP\uff08\u2212AR or \u2212BR\uff09will send the RF card number together with DAP number to PLC R3835\uff5eR3839. In mode 0 of function 14 \uff08RF CARD MODE\uff09, all the client needs to do is compare the card number. If it is OK, only set M1910 to 1 and then DAP will indicate \u201cOK\u201d, or \u201cERROR\u201d. When the RF card is out of sensing distance, DAP will pop up \u201cNEXT\u201d and clear the content of PLC R3838\uff5eR3839 to 0, which means available for another RF card. In mode 1 of function 14, as soon as DAP reads a card number, it will save it to R3835\uff5eR3839 with a beep. After the RF card exits, the 5 registers remain unchanged. <\/p>\n<p>Applicable occasions\uff1a<br \/>Where one set or multiple sets are connected but RF cards are not used frequently, the program to be applied will be a lot easier. But in the event of a card number read from different DAPs at the same time, it will be difficult for PLC to identify the information correctly. <\/p>\n<p>5\u3001Preset D2860\uff5eD2939 (16 differently-located DAP take on 5 registers individually, i.e. 80 registers in all, but the locations can be changed through function 15) control one point of M1880\uff5eM1895 separately when in use. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"3\">\n<p>D2860<\/p>\n<\/td>\n<td>\n<p>Card number <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>D2865<\/p>\n<\/td>\n<td>\n<p>Card number <\/p>\n<\/td>\n<td rowspan=\"3\">\n<p>D2870<\/p>\n<\/td>\n<td>\n<p>Card number <\/p>\n<\/td>\n<td rowspan=\"10\"><\/td>\n<td rowspan=\"3\">\n<p>D2935<\/p>\n<\/td>\n<td>\n<p>Card number <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>format <\/p>\n<\/td>\n<td>\n<p>format <\/p>\n<\/td>\n<td>\n<p>format <\/p>\n<\/td>\n<td>\n<p>format <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>N1<\/p>\n<\/td>\n<td>\n<p>N2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>N1<\/p>\n<\/td>\n<td>\n<p>N2<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>N1 <\/p>\n<\/td>\n<td>\n<p>N2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<td rowspan=\"5\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>N1 <\/p>\n<\/td>\n<td>\n<p>N2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>\u00d7\u00d7\u00d7\u00d7<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>D2861<\/p>\n<\/td>\n<td>\n<p>D2866<\/p>\n<\/td>\n<td>\n<p>D2871<\/p>\n<\/td>\n<td>\n<p>D2936<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>D2862<\/p>\n<\/td>\n<td>\n<p>D2867<\/p>\n<\/td>\n<td>\n<p>D2872<\/p>\n<\/td>\n<td>\n<p>D2937<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>D2863<\/p>\n<\/td>\n<td>\n<p>D2868<\/p>\n<\/td>\n<td>\n<p>D2873<\/p>\n<\/td>\n<td>\n<p>D2938<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\n<p>D2864<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>D2869<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>D3974<\/p>\n<\/td>\n<td rowspan=\"4\">\n<p>D2939<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>No. 1 <\/p>\n<\/td>\n<td>\n<p>No. 2 <\/p>\n<\/td>\n<td>\n<p>No. 3 <\/p>\n<\/td>\n<td>\n<p>No. 16 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u21d3<\/p>\n<\/td>\n<td>\n<p>\u21d3<\/p>\n<\/td>\n<td>\n<p>\u21d3<\/p>\n<\/td>\n<td>\n<p>\u21d3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>M1880 <\/p>\n<\/td>\n<td>\n<p>M1881 <\/p>\n<\/td>\n<td>\n<p>M1882 <\/p>\n<\/td>\n<td>\n<p>M1895 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Application measures\uff1a<br \/>The application measures are all described as the above-mentioned but that the storage places of card numbers and corresponding contacts for control are different. For example, in mode 0 of function 14, from No. 2 DAP sensing to the RF card, now no. 2 will send same card numbers to two different places in R3835\uff5eR3839 and D2865\uff5eD2869 (the content of the other registers remains unchanged), and all the client needs to do is control M1881 for the DAP to display \u201cOK\u201d or \u201cERROR\u201d. After the RF card exits, the content of the 10 registers R3835\uff5eR3839 and D2865\uff5eD2869 will be cleared to 0 (but remains unchanged in mode 1). <\/p>\n<p>Applicable occasions\uff1a<br \/>When several DAPs are connected, the RF card can be read in from different DAPs and each DAP has its independent card numbers storage places and control points so that no PLC misjudgment case occurs, but the programming will be more troublesome. <\/p>\n<p>\u203b If you do not want R3835\uff5eR3839 to display a card number value, you can use the Ladder program to fill in these registers with other fixed values. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>1.7Special message display function <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>In general monitoring mode and soft key mode (16 KEYS or 8 KEYS), the user can configure the DAP to display every kind of message under some circumstances, and the two-line display on the LCD can be c ontrolled separately to simultaneously display different messages. Every message is 1~511 words and numbers (ASCII code) long, in which a maximum of 16 variables (if variables with 32-digit are not used, then it can use up to 25) can be included. When a message has more than 16 words, the message will be displaced left for display, in whic h the moving s peed or pause time can be configured flexibly. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p> 1.7.1Message display application <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>The FB-DAPB(R) can be connected up to 16 sets (Number 1~16). Each DAP not only can display different messages individually but make all the DAPs connected display the same message simultaneously. If you go to a special contact (R3780~M3813) set by Enable, the DAP will display the message ASCII Code) indicated by the corresponding indication register \uff08R3780\uff5eM3813\uff09. The content of the indication register is the start register of messages, i.e. start of ASCII Code. The indication register content can be changed anytime in order to change and display different messages. <\/p>\n<p>The following is a list of corresponding special c ontacts and indication registers when each DAP is displaying a message for control. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td rowspan=\"2\">\n<p>Number of a message displayed <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>LCD line 1 <\/p>\n<\/td>\n<td colspan=\"2\">\n<p>LCD line 2 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Special contact <\/p>\n<\/td>\n<td>\n<p>Indication register <\/p>\n<\/td>\n<td>\n<p>Special contact <\/p>\n<\/td>\n<td>\n<p>Indication register <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1\uff5e16 <\/p>\n<\/td>\n<td>\n<p>M1800 <\/p>\n<\/td>\n<td>\n<p>R3780 <\/p>\n<\/td>\n<td>\n<p>M1801 <\/p>\n<\/td>\n<td>\n<p>R3781 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>1 <\/p>\n<\/td>\n<td>\n<p>M1802 <\/p>\n<\/td>\n<td>\n<p>R3782 <\/p>\n<\/td>\n<td>\n<p>M1803 <\/p>\n<\/td>\n<td>\n<p>R3783 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>2 <\/p>\n<\/td>\n<td>\n<p>M1804 <\/p>\n<\/td>\n<td>\n<p>R3784 <\/p>\n<\/td>\n<td>\n<p>M1805 <\/p>\n<\/td>\n<td>\n<p>R3785 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>3 <\/p>\n<\/td>\n<td>\n<p>M1806 <\/p>\n<\/td>\n<td>\n<p>R3786 <\/p>\n<\/td>\n<td>\n<p>M1807 <\/p>\n<\/td>\n<td>\n<p>R3787 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>4 <\/p>\n<\/td>\n<td>\n<p>M1808 <\/p>\n<\/td>\n<td>\n<p>R3788 <\/p>\n<\/td>\n<td>\n<p>M1809 <\/p>\n<\/td>\n<td>\n<p>R3789 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>5 <\/p>\n<\/td>\n<td>\n<p>M1810 <\/p>\n<\/td>\n<td>\n<p>R3790 <\/p>\n<\/td>\n<td>\n<p>M1811 <\/p>\n<\/td>\n<td>\n<p>R3791 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>6 <\/p>\n<\/td>\n<td>\n<p>M1812 <\/p>\n<\/td>\n<td>\n<p>R3792 <\/p>\n<\/td>\n<td>\n<p>M1813 <\/p>\n<\/td>\n<td>\n<p>R3793 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>7 <\/p>\n<\/td>\n<td>\n<p>M1814 <\/p>\n<\/td>\n<td>\n<p>R3794 <\/p>\n<\/td>\n<td>\n<p>M1815 <\/p>\n<\/td>\n<td>\n<p>R3795 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>8 <\/p>\n<\/td>\n<td>\n<p>M1816 <\/p>\n<\/td>\n<td>\n<p>R3796 <\/p>\n<\/td>\n<td>\n<p>M1817 <\/p>\n<\/td>\n<td>\n<p>R3797 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>9 <\/p>\n<\/td>\n<td>\n<p>M1818 <\/p>\n<\/td>\n<td>\n<p>R3798 <\/p>\n<\/td>\n<td>\n<p>M1819 <\/p>\n<\/td>\n<td>\n<p>R3799 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>10 <\/p>\n<\/td>\n<td>\n<p>M1820 <\/p>\n<\/td>\n<td>\n<p>R3800 <\/p>\n<\/td>\n<td>\n<p>M1821 <\/p>\n<\/td>\n<td>\n<p>R3801 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>11 <\/p>\n<\/td>\n<td>\n<p>M1822 <\/p>\n<\/td>\n<td>\n<p>R3802 <\/p>\n<\/td>\n<td>\n<p>M1823 <\/p>\n<\/td>\n<td>\n<p>R3803 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>12 <\/p>\n<\/td>\n<td>\n<p>M1824 <\/p>\n<\/td>\n<td>\n<p>R3804 <\/p>\n<\/td>\n<td>\n<p>M1825 <\/p>\n<\/td>\n<td>\n<p>R3805 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>13 <\/p>\n<\/td>\n<td>\n<p>M1826 <\/p>\n<\/td>\n<td>\n<p>R3806 <\/p>\n<\/td>\n<td>\n<p>M1827 <\/p>\n<\/td>\n<td>\n<p>R3807 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>14 <\/p>\n<\/td>\n<td>\n<p>M1828 <\/p>\n<\/td>\n<td>\n<p>R3808 <\/p>\n<\/td>\n<td>\n<p>M1829 <\/p>\n<\/td>\n<td>\n<p>R3809 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>15 <\/p>\n<\/td>\n<td>\n<p>M1830 <\/p>\n<\/td>\n<td>\n<p>R3810 <\/p>\n<\/td>\n<td>\n<p>M1831 <\/p>\n<\/td>\n<td>\n<p>R3811 <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>16 <\/p>\n<\/td>\n<td>\n<p>M1832 <\/p>\n<\/td>\n<td>\n<p>R3812 <\/p>\n<\/td>\n<td>\n<p>M1833 <\/p>\n<\/td>\n<td>\n<p>R3813 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u3008Example\u3009Assume M1803 from 0\u21921, R3783=100 <\/p>\n<p>\u203b The start register of a message <br \/>indicated by an indication register <br \/>means\uff1a<br \/>0\uff5e8070\uff1aindicating R0\uff5eR8070 <br \/>10000\uff5e13070\uff1aindicating D0\uff5eD3070<\/p>\n<p>\u203b Special contacts M1800 and M1801 have a priority display function. <\/p>\n<p>\u203b M1911 can control an alarm buzzer whether to sound or not. If M1911=0\uff08preset\uff09, it shall be activated. <\/p>\n<p>Result\uff1aLine 2 of No. 1 of the LCD will display messages in ASCII Code with R100 start. <\/p>\n<p>\u3008Example\u3009 Assume M1828 from 0\u21921, R3808=10000 <br \/>\tResult\uff1aLine 1 of No. 14 of the LCD will display messages in ASCII Code with D0 start. <\/p>\n<p>\u3008Example\u3009 Assume M1801 from 0\u21921, R3781=0 <br \/>\tResult\uff1aLine 2 of all the DAPs will display messages in ASCII Code with R0 start. <\/p>\n<p> 1.7.2The Information formats of messages\uff08ASCII Table\uff09<\/p>\n<p>The information formats of messages are very similar to the file information in ASCII in chapter 15 in the Advanced Manual that are all categorized as fixed background information and dynamic variable information. The first can be words in English, numbers, or signs, and the second binary, decimal or hexadecimal system. <\/p>\n<p>Length of a message is 1~511 digits (including blank spaces), but because there are only 16 digits a line in a DAP LCD, if a message has more than 16 digits, it will be displayed automatically toward the left (preset moving one time a second); if less than 16 digits, the tail will be filled in with blank digits and no moving occurs. <\/p>\n<p>To edit a message, the WinProladder ASCII Editor can be applied. The editing command formats are as follows: <\/p>\n<p>1 Background information format <\/p>\n<p>Any ASCII Code digits quoted with  &#8216;  &#8216; can be background information. To display a single quotation mark as <\/p>\n<p>such, two continuous quotation marks are a must. Example: <\/p>\n<p>&#8216; I &#8216; &#8216;M A BOY&#8217; will be displayed I&#8217;M A BOY <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>2Variable information format <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\uff0c&quot;8 \uff0e2R0 D&quot;\uff0c\u2197\u2191  \u2191\u2196<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Total <\/p>\n<\/td>\n<td>\n<p>Decimal <\/p>\n<\/td>\n<td>\n<p>Variable<\/p>\n<\/td>\n<td>\n<p>Carry <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>variable <\/p>\n<\/td>\n<td>\n<p>point <\/p>\n<\/td>\n<td rowspan=\"2\">\n<p>Register<\/p>\n<\/td>\n<td>\n<p>code <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>count <\/p>\n<\/td>\n<td>\n<p>count<\/p>\n<\/td>\n<td>\n<p>displayed<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>displayed<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Description information in a pair of dual quotation marks \u301d \u301eis used to indicate the register address (number) <\/p>\n<p>storing the variable information and in what format and carry code to display. <\/p>\n<p> Total variable count displayed\uff1aIn this case, the value (including minus) of the variable R0 is displayed in a field with 8 digits. If the variable value is bigger than the total variable count displayed, the digits further from the point will be cut. If not enough, blank spaces will fill in. <\/p>\n<p> Decimal point count\uff1athe decimal point count in the total digits. In this case, with a total count of 8 digits, the decimal point count is 2. The decimal point sign \u301d\uff0e\u301e as such possesses one digit and there are 5 digits left in the integral part. <\/p>\n<p> Contacts\uff1agenerally displayed as ON or OFF (total digit count displayed is set to a fixed 3), but if added with binary system B in the tail, 0\/1 will be displayed (total digit count fixed 1) <\/p>\n<p> Carry code\uff1acan be hexadecimal H, decimal D (the carry code will use decimal if without indication, so D can be \tomitted.), or binary B, etc., but a 32 digit variable can not be displayed with binary system. <\/p>\n<p>In this case, R0\u2019s content value is 32768. In 8.2 format the result is displayed as: <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>3<\/p>\n<\/td>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>7<\/p>\n<\/td>\n<td>\n<p>.<\/p>\n<\/td>\n<td>\n<p>6<\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>If the format is changed from 8.2 to 5.1, then the result becomes: <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-103\/fbs-ins-en-103-061.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>2<\/p>\n<\/td>\n<td>\n<p>7<\/p>\n<\/td>\n<td>\n<p>6<\/p>\n<\/td>\n<td>\n<p>.<\/p>\n<\/td>\n<td>\n<p>8<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>3Basic command signs <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>nS <\/p>\n<\/td>\n<td>\n<p>Left move speed (repeatable) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Message displayed at a left LCD move per n\uff081\uff5e255\uff09\u00d7 0.1s\u3002<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>nP <\/p>\n<\/td>\n<td>\n<p>Stop move (repeatable) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Message stop in\uff081\uff5e255\uff09\u00d7 0.1s\uff0cand then move left at a configured speed. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\uff0c<\/p>\n<\/td>\n<td>\n<p>Comma <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>Used as a statement to divide the file information. Information between two neighboring commas is a complete and executable statement (unnecessary for the start and end of a file). <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>END<\/p>\n<\/td>\n<td>\n<p>End of a file <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u203b nS and nP commands will not be activated until after the information following them moves to the left first place on the LCD display. They can have a repeatable arrangement of any place in ASCII, but the same command cannot be connected together. <\/p>\n<p>\u3008Example\u3009 Information edited with WinProladder ASCII file editor. R0 is a start register of an ASCII file \tand the file information is shown as follows\uff1a<\/p>\n<p>5S\uff0c20P\uff0c\u2019A=\u2019\uff0c\u301d6.2R3840\u301e\uff0c\u2019B=\u2019\uff0c\u301d6.2R3841\u301e\uff0c30P\uff0c\u2019C\uff1a \u2019\uff0c\u301d1M0B\u301e\uff0c\u2019D\uff1a \u2019\uff0c\u301d1M1B\u301e\uff0c\u2019E\uff1a \u2019\uff0c\u301d1M2B\u301e\uff0c \u2019 \u2019\uff0cEND <\/p>\n<p>If M1800 from 0\u21921 and R3780=0\uff08i.e. R0\uff09, Line 1 of the LCD of DAPs of all numbers is shown as follows\uff1a<\/p>\n<p>\u2022\u2022\u2022\u2022\u2022\u2022  \u2022\u2022\u2022\u2022\u2022\u2022\u2022<\/p>\n<p>\tMove a place left after stopping 2 seconds<br \/>\u2022\u2022\u2022\u2022\u2022  \u2022\u2022\u2022\u2022\u2022\u2022\u2022 \u2022\t\t\ufe35\twhen <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Move a place left per 0.5s<\/p>\n<p>\u2022\u2022\u2022\u2022\u2022\u2022\u2022 \u2022\u2022 \u2022  \u2022\u2022<\/p>\n<\/td>\n<td>\n<p>M1800 <br \/>And <br \/>R3780 <br \/>Are <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\t\tNot changed\t\t\t\ufe36\u2022\u2022 \u2022  \u2022\u2022 \u2022 \u2022\u2022 \u2022 <\/p>\n<p>\tAfter stopping 3s and then move a place left\u2022 \u2022  \u2022\u2022 \u2022 \u2022\u2022 \u2022 \u2022<\/p>\n<p>Return to display again after reaching the end of the ASCII<\/p>\n<p> Variable information is renewable anytime. <\/p>\n<p> To display another message, just change R3780 value and not for M1800. <\/p>\n<p>MEMO <\/p>\n","protected":false},"excerpt":{"rendered":"<p>In addition to timer, counter, register, and contact da [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[34],"tags":[],"class_list":["post-3437","post","type-post","status-publish","format-standard","hentry","category-en-fbs-ins"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3437"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3437\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3437"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3437"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}