{"id":3439,"date":"2026-11-17T21:35:39","date_gmt":"2026-11-17T13:35:39","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-ins-en-105\/"},"modified":"2026-11-17T21:35:39","modified_gmt":"2026-11-17T13:35:39","slug":"fbs-ins-en-105","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/fbs-ins-en-105\/","title":{"rendered":"Appendix 2 FBs BDAP User\u2019s Manual (V1.0)"},"content":{"rendered":"<p> The function of the data access board (FBs-BDAP) is mainly used for displaying and setting of the calendar time and discrete and register data of PLC. For the discrete elements, user can perform the disable or enable function also can set or reset its state. For the registers, the contents can be set and displayed in unsigned or signed decimal format and hexadecimal format. This unit should be mounted on the PLC main unit while install. <\/p>\n<p> 1.1 FBs BDAP Function Description <\/p>\n<p>There are some notations were referred in following sections and described at below: <\/p>\n<p>\u3010T\u3011<strong>:<\/strong> Current value and on\/off status of timer <\/p>\n<p>\u3010C\u3011<strong>:<\/strong> Current value and on\/off status of counter <\/p>\n<p>\u3010D\u3011<strong>:<\/strong> Data register(D type) <\/p>\n<p>\u3010R\u3011<strong>:<\/strong> Data register(R type) <\/p>\n<p>\u3010F\u3011<strong>:<\/strong> File register <\/p>\n<p>\u3010X\u3011<strong>:<\/strong> Discrete Input (DI) <\/p>\n<p>\u3010Y\u3011<strong>:<\/strong> Discrete Output(DO) <\/p>\n<p>\u3010M\u3011<strong>:<\/strong> Internal relay <\/p>\n<p>\u3010S\u3011<strong>:<\/strong> Step relay <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<p> Feature <\/p>\n<\/td>\n<td>\n<p> Description <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Cal<\/p>\n<\/td>\n<td>\n<p>Calendar Function* 1<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Display <\/p>\n<\/td>\n<td>\n<p>Display current Year, Month, Date, Hour and minute data <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Setting <\/p>\n<\/td>\n<td>\n<p>Set Year, Month, Date, Hour and minute data <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Sta<\/p>\n<\/td>\n<td>\n<p>Status Display Function <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>Discrete Element <\/p>\n<\/td>\n<td>\n<p>Display the state and enable\/disable status of X,Y,M,S element <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>16 bit Register <\/p>\n<\/td>\n<td>\n<p>Display the current value of T, C, D, R, F register. Three display formats (unsigned\/signed\/hexadecimal) can be chosen. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>32 bit Register <\/p>\n<\/td>\n<td>\n<p>Display the current value of C, D, R, F register. Three display formats (unsigned\/signed\/hexadecimal) can be chosen. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Force On\/Off Function <\/p>\n<\/td>\n<td>\n<p>Force the state of X, Y, M, S to be On or Off <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Disable\/Enable Function <\/p>\n<\/td>\n<td>\n<p>Control the state of X, Y, M, S to be enabled or disabled <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Reg Fun<\/p>\n<\/td>\n<td>\n<p>ister Content Modification ction <\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>16 bit Register <\/p>\n<\/td>\n<td>\n<p>Modify the current value of T, C, D, R, F register. Three display formats (unsigned\/signed\/hexadecimal) can be chosen. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p>32 bit Register <\/p>\n<\/td>\n<td>\n<p>Modify the current value of C, D, R, F register. Three display formats (unsigned\/signed\/hexadecimal) can be chosen. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Setting and Display of PLC Station Number Function <\/p>\n<\/td>\n<td>\n<p>Display and set the PLC station number. <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p>Force PLC Run\/Stop Function <\/p>\n<\/td>\n<td>\n<p>Force the PLC to run or stop logic solving and I\/O service. <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> 1.2 FBs BDAP Display Legend <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-001.png\" \/><\/p>\n<p>\u2460\u201cRUN\u201d indicator. When the PLC is in running state, this symbol will be appeared. <\/p>\n<p>\u2461\u201cSTOP\u201d indicator. When the PLC is in stop state, this symbol will be appeared. <\/p>\n<p>\u2462\u201cON\u201d indicator. When the selected element is Timer or Counter, this symbol will be \tappeared when the corresponding state is on. <\/p>\n<p>\u2463\u201cOFF\u201d indicator. When the selected element is Timer or Counter, this symbol will be \tappeared when the corresponding state is off. <\/p>\n<p>\u2464\u201cD\u201d indicators. When the selected element is 32 bit register, the \u201cD\u201d symbol will be \tappeared. <\/p>\n<p>\u2465Element symbols for selection. There are nine element types can be chosen, those \tare T, C, D, R, F, X, Y, M and S. <\/p>\n<p>\u2466Reference number or year display, The sequence number of the selected element or \tthe year part of the calendar. <\/p>\n<p>\u2467Value display or hour and minute display. For 16 bit register, it represents the current value of 16 bit content. For 32 bit register, it represents the portion of the number above 5t h digit (million) in decimal or MSB word in hexadecimal format. It also represents the state of discrete element or hour and minute part of the calendar. <\/p>\n<p>\u2468Value display or month and day display. For 32 bit register, it represents the lower 5 digit portion of the number in decimal or LSB word in hexadecimal format. It also represents the enable\/disable state of discrete element or month and day part of the calendar. <\/p>\n<p> 1.3 FBs BDAP Operation Procedure <\/p>\n<p>Operation Keypads: There are six keypads in total for operation. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td colspan=\"2\">\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>ESC <strong>: <\/strong>Escape key <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OK <\/p>\n<\/td>\n<td>\n<p><strong>: <\/strong>OK key <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\uff0d<\/p>\n<\/td>\n<td>\n<p><strong>: <\/strong>\u201c\uff0d\u201d key <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\uff0b<\/p>\n<\/td>\n<td>\n<p><strong>: <\/strong>\u201c\uff0b\u201d key <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u00c6<\/p>\n<\/td>\n<td>\n<p><strong>: <\/strong>\u201c\u00c6\u201d key(shift right) <\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>\u00c5<\/p>\n<\/td>\n<td>\n<p><strong>: <\/strong>\u201c\u00c5\u201d key(shift left) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p> Default display mode: Calendar Display <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-002.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb1Select the field to be changed, selected field will be blinked <\/p>\n<p>\u25cb2Enter the new value <\/p>\n<p>\u25cb3Enter status monitoring display screen <\/p>\n<p>\u25cb4Use \u00c5 key\u3001\u00c6 key select the element type to be monitoring. The selected type will be <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>blinked. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb5Under calendar display mode, press\uff0bkey to force PLC stop or run <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u2465Under calendar display mode, press\uff0dkey to display and modify the PLC station \tnumber <br \/>\u2466 Under calendar display mode, press\u00c5key, can display the firmware version of PLC \tand BDAP. <\/p>\n<p>Note: No matter at which display screen, press &lt;ESC&gt; with 2 seconds will lead the screen to calendar display. <\/p>\n<p>Discrete Element Monitoring: <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-003.png\" \/><\/p>\n<p>\u25cb1Discrete element(X\u3001Y\u3001M\u3001S) display screen show five consecutive points of status at one time. The \t\tupper row is on\/off status while the lower row is disable\/enable status. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb2Element reference number adjust <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key:Increase the reference number by 5 <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey:Decrease the reference number by 5 <\/p>\n<p>\u25cb3Enter the element status editing state. The selected point will be blinked. <\/p>\n<p>\u25cb4Modification of element ON\/OFF\u3001Enable\/Disable status <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key:Change the ON\/OFF status(toggle operation) <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey:Change the Enable\/Disable status(toggle operation) <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u00c6 key:Move cursor to the lower point to be edited(decrease the reference number) <\/p>\n<p>\u00c5 key:Move cursor to the higher point to be edited(increase the reference number)<\/p>\n<p>\u25cb5Finish the editing. <\/p>\n<p>Timer\/Counter Status Monitoring: <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-004.png\" \/><\/p>\n<p>\u25cb1The current value ofT, C elementif reach the preset value will show\u201dON\u201d, otherwise \t\twill show\u201dOFF\u201d <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb2Reference number adjust <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key:Reference number decreased by one <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey:Reference number increased by one <\/p>\n<p>\u25cb3Enter editing mode. The digit to be changed will be blinked. <\/p>\n<p>\u25cb4Modify value <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key:Increased by one <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey:Decreased by one <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u00c6 key: Move to the right digit <\/p>\n<p>\u00c5 key: Move to the left digit. <\/p>\n<p>\u25cb5Finish the editing and increase the reference number by one and back to\u25cb<\/p>\n<p>\u203b When monitoring the counter element, if the reference number is great than 200 then the display value will be in 32 bit format(C200~C255 are 32bit counter) <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-005.png\" \/><\/p>\n<p>\u203b When monitoring the timer element, the decimal point of current value will be set accordingly. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-006.png\" \/><\/p>\n<p>Register Status Monitoring:<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-007.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb1Default unsigned 16 bit decimal value display<\/p>\n<p>\u25cb2Adjust the reference number and select the display format <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key:Increase the reference number by one when 16 bit display format, by two <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>when in 32 bit display format. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey:Decrease the reference number by one when 16 bit display format, by two <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>when in 32 bit display format. <\/p>\n<p>\u00c6 key: Display format selection. There are signed decimal, unsigned decimal and hexadecimal display format can <\/p>\n<p>be selected. Each depression of \u00c6 key can change the format once. <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-008.png\" \/> &lt;16 bit hexadecimal display&gt;<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-009.png\" \/> &lt;16 bit signed decimal display&gt; <\/p>\n<p>\u00c5  key: 16 bit\/32 bit display format selection, Each depression of  \u00c5 key will toggle the <\/p>\n<p>display format between these two modes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-010.png\" \/> &lt;32 bit unsigned decimal&gt; <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-011.png\" \/> &lt;32 bit hexadecimal display&gt; <\/p>\n<p><img decoding=\"async\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/fbs-ins-en-105\/fbs-ins-en-105-012.png\" \/> &lt;32 bit signed decimal display&gt; <\/p>\n<p>\u25cb3Enter editing mode. The digit to be edited will be blinked. <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>\u25cb4Modify digit value <\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0b key: Increased by one<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td><\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\uff0dkey: Decreased by one <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p>\u00c6 key: Move cursor to the right digit<\/p>\n<p>\u00c5 key: Move cursor to the left digit <\/p>\n<p>\u25cb5Finish the editing and automatically point to the next available reference number then <\/p>\n<p>back to\u25cb<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The function of the data access board (FBs-BDAP) is mai [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[34],"tags":[],"class_list":["post-3439","post","type-post","status-publish","format-standard","hentry","category-en-fbs-ins"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3439"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3439\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}