{"id":3484,"date":"2026-11-19T18:41:27","date_gmt":"2026-11-19T10:41:27","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/19\/iocoupler-man-en-08\/"},"modified":"2026-11-19T21:24:04","modified_gmt":"2026-11-19T13:24:04","slug":"iocoupler-man-en-08","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/19\/iocoupler-man-en-08\/","title":{"rendered":"IO Coupler Manual \u2013 Appendix A Description of LED Indicator"},"content":{"rendered":"<h3>MC0EN<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 1\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-001.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2IO Coupler MC0EN<\/p>\n<p class=\"has-text-align-center\">Network-type module( IO Coupler MC0EN )<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Constantly lit when powered on<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Flashes 10 times\/second: System running<\/p>\n<p>Flashes 1 time\/second: System running, ready to restore factory default settings<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR1<\/p>\n<p>ERR2<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>ERR1: Off, ERR2: Off: System normal.<\/p>\n<p>ERR1: On, ERR2: Off: ERR_SERVICE persistent task-related error.<\/p>\n<p>ERR1: Off, ERR2: On: ERR_IO expansion module-related error.<\/p>\n<p>ERR1: On, ERR2: On: ERR_SYS major system error.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ethernet LINK\/ACT<\/p>\n<\/td>\n<td>\n<p>Yellow<\/p>\n<\/td>\n<td>\n<p>Solid Off: Invalid Link\u3002<\/p>\n<p>Flashing: Dark for 80 ms, then bright for 80 ms \uff0cTX\/RX Activity\u3002<\/p>\n<p>Solid On: Invalid Link\u3002<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ethernet STATUS<\/p>\n<\/td>\n<td>\n<p>Green<\/p>\n<\/td>\n<td>\n<p>Solid Off: No IP Address Obtained<\/p>\n<p>Flashing once per second in DHCP mode: Obtaining IP Address<\/p>\n<p>Solid On: IP Address Obtained<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">MC0EN indicator description<\/p>\n<h3>M16X<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 2\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-002.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion DI_M16X<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>X1\u2013X16 indicator<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Lit when ON<\/p>\n<p>Dark when OFF<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Expansion DI_M16X indicator description<\/p>\n<h3>M16YT<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 3\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-003.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion DO_M16Y<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y1\u2013Y16 indicator<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Lit when ON<\/p>\n<p>Dark when OFF<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Expansion DO_M16Y indicator description<\/p>\n<h3>M1616XYT<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 4\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-004.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion XY_1616XYT<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Y1\u2013Y16 indicator<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Lit when ON<\/p>\n<p>Dark when OFF<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>X1\u2013X16 indicator<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Lit when ON<\/p>\n<p>Dark when OFF<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2<strong>Expansion DIO_M1616XYT indicator description<\/strong><\/p>\n<h3>M04AD\/M04ADR<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 5\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-005.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion AI_M04AD\/M04ADR<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Slow flashing when shutdown<\/p>\n<p>Quick flashing when running<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Action mode under warning or major error mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC<\/p>\n<\/td>\n<td>\n<p>Orange<\/p>\n<\/td>\n<td>\n<p>Constant light for signal conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Alarm indicator<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Expansion AI_M04AD\/M04ADR indicator description<\/p>\n<h3>M04DA\/M04DAR<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 6\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-006.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion AO_M04DA\/M04DR<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Slow flashing when shutdown<\/p>\n<p>Quick flashing when running<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Action mode under warning or major error mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC<\/p>\n<\/td>\n<td>\n<p>Orange<\/p>\n<\/td>\n<td>\n<p>Constant light for signal conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Alarm indicator<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Expansion AO_M04DA\/M04DAR indicator description<\/p>\n<h3>M04TC\/M04TCR<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 7\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-007.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Expansion  TC_M04TC\/M04TCR<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>RUN<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Slow flashing when shutdown<\/p>\n<p>Quick flashing when running<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ERR<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Action mode under warning or major error mode<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ADC<\/p>\n<\/td>\n<td>\n<p>Orange<\/p>\n<\/td>\n<td>\n<p>Constant light for signal conversion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>ALM<\/p>\n<\/td>\n<td>\n<p>Red<\/p>\n<\/td>\n<td>\n<p>Alarm indicator<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Expansion TC_M04TC\/M04TCR indicator description<\/p>\n<h3>POWER<\/h3>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Appendix A Description of LED Indicator - 8\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iocoupler-man-en-08\/iocoupler-man-en-08-008.png\" \/><\/p>\n<p class=\"has-text-align-center\">\u25b2Power Module<\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p>Indicator<\/p>\n<\/td>\n<td>\n<p>Color<\/p>\n<\/td>\n<td>\n<p>Definition<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PWR<\/p>\n<\/td>\n<td>\n<p>Yellow-green<\/p>\n<\/td>\n<td>\n<p>Constant light for being energized.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p class=\"has-text-align-center\">\u25b2Power Module  indicator description<\/p>\n","protected":false},"excerpt":{"rendered":"<p>MC0EN \u25b2IO Coupler MC0EN Network-type module( IO Coupler [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[62],"tags":[],"class_list":["post-3484","post","type-post","status-publish","format-standard","hentry","category-en-iocoupler-man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3484"}],"version-history":[{"count":1,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3484\/revisions"}],"predecessor-version":[{"id":3485,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3484\/revisions\/3485"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3484"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3484"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}