{"id":3514,"date":"2026-11-19T18:42:08","date_gmt":"2026-11-19T10:42:08","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/19\/iot-man-en-05\/"},"modified":"2026-11-19T20:56:59","modified_gmt":"2026-11-19T12:56:59","slug":"iot-man-en-05","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/19\/iot-man-en-05\/","title":{"rendered":"FATEK IoT Manual \u2013 Chapter 5 iAccess Remote Maintenance"},"content":{"rendered":"<p>iAccess Insight is a FATEK IoT tool that assists users in remote updates and maintenance of devices. You can find it in FvDesigner.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 1\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-001.png\" \/><\/p>\n<p>Alternatively, you can download the standalone installation package.<\/p>\n<p><a href=\"https:\/\/www.fatek.com\/download.php?act=list&amp;cid=16\">https:\/\/www.fatek.com\/download.php?act=list&amp;cid=16<\/a><\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 2\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-002.png\" \/><\/p>\n<p>After opening the application, select the server you want to connect to, then fill in the Customer ID, Account, and Password to log in.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 3\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-003.png\" \/><\/p>\n<p>After logging in, you will see the iAccess devices that have been Enable.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 4\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-004.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p class=\"has-text-align-center\">Item<\/p>\n<\/td>\n<td>\n<p class=\"has-text-align-center\">Describe<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>Device name, need to login to the website to set.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Product Type<\/p>\n<\/td>\n<td>\n<p>Display the product type.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model Name<\/p>\n<\/td>\n<td>\n<p>Display the group\u2019s model name.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>iAccess Status<\/p>\n<\/td>\n<td>\n<p>Display the current status of the device.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Refresh<\/p>\n<\/td>\n<td>\n<p>Refresh the device status.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Logout<\/p>\n<\/td>\n<td>\n<p>Logout the account.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Detail<\/p>\n<\/td>\n<td>\n<p>Select the device then enter the remote function page.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h3>5.1 HMI Maintenance<\/h3>\n<p>Click on the HMI to enter the device control page.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 5\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-005.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p class=\"has-text-align-center\">Item<\/p>\n<\/td>\n<td>\n<p class=\"has-text-align-center\">Describe<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Name<\/p>\n<\/td>\n<td>\n<p>Device name.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Model<\/p>\n<\/td>\n<td>\n<p>Display the device model.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Firmware version<\/p>\n<\/td>\n<td>\n<p>Display the device firmware version.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>OS version<\/p>\n<\/td>\n<td>\n<p>Display the device OS version.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Env version<\/p>\n<\/td>\n<td>\n<p>Display the device environment package version.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>iAccess Status<\/p>\n<\/td>\n<td>\n<p>Display the connect status.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>iAccess LID<\/p>\n<\/td>\n<td>\n<p>Display the LID type.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>5.1.1 Upload\/Download<\/h4>\n<p>Users can remotely upload and download projects for HMI.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 6\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-006.png\" \/><\/p>\n<p>If you encounter mismatches between the project and firmware when using the standalone installation package of iAccess Insight, please update to the latest version of iAccess Insight from the official website.<\/p>\n<h4>5.1.2 Pass Through<\/h4>\n<p>Using Pass Through allows remote control of the PLC.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 7\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-007.png\" \/><\/p>\n<div class=\"fatek-tw\">\n<table>\n<tr>\n<td>\n<p class=\"has-text-align-center\">Item<\/p>\n<\/td>\n<td>\n<p class=\"has-text-align-center\">Describe<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Pass Through by<\/p>\n<\/td>\n<td>\n<p>Choose between using IP or iAccess Virtual COM.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>PLC Type<\/p>\n<\/td>\n<td>\n<p>Select how the HMI is connected to the PLC.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comrection Setting-PC<\/p>\n<\/td>\n<td>\n<p>Configure the method of connection to the remote HMI.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comrection Setting-HMI<\/p>\n<\/td>\n<td>\n<p>Set up the serial port for the HMI to connect to the PLC; this step is not necessary if the HMI and PLC use network communication.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Comrection Setting-PLC<\/p>\n<\/td>\n<td>\n<p>Configure the connection parameters for the remote PLC.<\/p>\n<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h4>5.1.3 File Transfer<\/h4>\n<p>Users can connect to the remote HMI to access the internal folders.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 8\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-008.png\" \/><\/p>\n<h4>5.1.4 Viewer<\/h4>\n<p>The Viewer function supports users to control the screen via a computer or app. This feature needs to be enabled in the system settings of the HMI beforehand.<\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 9\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-009.png\" \/><\/p>\n<p class=\"has-text-align-center\"><img decoding=\"async\" alt=\"Chapter 5 iAccess Remote Maintenance - 10\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/fatek\/iot-man-en-05\/iot-man-en-05-010.png\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>iAccess Insight is a FATEK IoT tool that assists users  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[66],"tags":[],"class_list":["post-3514","post","type-post","status-publish","format-standard","hentry","category-en-iot-man"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3514","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3514"}],"version-history":[{"count":1,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3514\/revisions"}],"predecessor-version":[{"id":3515,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3514\/revisions\/3515"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3514"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3514"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3514"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}