{"id":3587,"date":"2026-11-18T14:44:42","date_gmt":"2026-11-18T06:44:42","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/18\/how-to-use-data-shares\/"},"modified":"2026-11-24T11:03:53","modified_gmt":"2026-11-24T03:03:53","slug":"how-to-use-data-shares","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/18\/how-to-use-data-shares\/","title":{"rendered":"[MPLC] How to use Data Shares"},"content":{"rendered":"<h3 class=\"wp-block-heading\"><strong>Required Software &amp; Firmware<\/strong><\/h3>\n<p class=\"wp-block-paragraph\">Ensure all PLC and module versions meet or exceed these baselines before setup.<\/p>\n<p class=\"wp-block-paragraph\">Data Share can communicate with FBs and HMI.<\/p>\n<h4 class=\"wp-block-heading\"><strong>Network Configuration Example<\/strong><\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>PLC Software<\/strong><\/td>\n<td><strong>Uperlogic_v1.0.19_installer<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>PLC OS Version<\/strong><\/td>\n<td><strong>1_0_62 or later<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>CBEX OS Version<\/strong><\/td>\n<td><strong>CBEH2_CBES(G02)_CMES_V0302<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p class=\"wp-block-paragraph\">Match subnet mask and gateway across PC and PLCs with unique host octets.<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>PC Ethernet Settings<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>IP Assignment<\/strong><\/td>\n<td>Manual (Static)<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv4 Address<\/strong><\/td>\n<td><strong>192.168.2.100<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Subnet Mask<\/strong><\/td>\n<td><strong>255.255.255.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Default Gateway<\/strong><\/td>\n<td><strong>192.168.2.1<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">M PLC Ethernet Settings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>DHCP<\/strong><\/td>\n<td>Disabled<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv4 Address<\/strong><\/td>\n<td>192.168.2.4 (Unique X)<\/td>\n<\/tr>\n<tr>\n<td>Subnet Mask<\/td>\n<td>255.255.255.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\"><strong>Multi-PLC Communication Setup<\/strong><\/h4>\n<p class=\"wp-block-paragraph\">Each PLC on the network must be assigned a distinct IPv4 address.<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Parameter<\/strong><\/td>\n<td><strong>1st PLC (Station 0)<\/strong><\/td>\n<td><strong>2nd PLC (Station 1)<\/strong><\/td>\n<td><strong>Rule<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>DHCP<\/strong><\/td>\n<td>Disabled<\/td>\n<td>Disabled<\/td>\n<td>Static IP required<\/td>\n<\/tr>\n<tr>\n<td><strong>IP Address<\/strong><\/td>\n<td>192.168.2.4<\/td>\n<td>192.168.2.5<\/td>\n<td>Must be unique per PLC<\/td>\n<\/tr>\n<tr>\n<td><strong>Subnet Mask<\/strong><\/td>\n<td>255.255.255.0<\/td>\n<td>255.255.255.0<\/td>\n<td>Identical across network<\/td>\n<\/tr>\n<tr>\n<td><strong>Gateway<\/strong><\/td>\n<td>192.168.2.1<\/td>\n<td>192.168.2.1<\/td>\n<td>Identical across network<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\"><strong>Data Sharer Configuration<\/strong><\/h4>\n<p class=\"wp-block-paragraph\">Double-click <strong>Server Configuration<\/strong> in UperLogic Project Management to open Data Sharer.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"794\" height=\"409\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/34B48564-7DFC-4E29-971A-A875BC5895A1.png\" alt=\"\" class=\"wp-image-1107\"><\/figure>\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"664\" height=\"405\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/4C7A37B4-571F-455B-A98A-80B4F2EB4F57.png\" alt=\"\" class=\"wp-image-1108\" style=\"width:720px;height:auto\"><\/figure>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Parameter<\/strong><\/td>\n<td><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Enable \/ Disable<\/strong><\/td>\n<td>Enable or disable the Data Sharer service<\/td>\n<\/tr>\n<tr>\n<td><strong>Port<\/strong><\/td>\n<td>Set UDP communication port (e.g., 9000; must match across all stations)<\/td>\n<\/tr>\n<tr>\n<td><strong>Local Station ID<\/strong><\/td>\n<td>Assign local station ID from 0 to 15 (unique per node)<\/td>\n<\/tr>\n<tr>\n<td><strong>Command Interval (ms)<\/strong><\/td>\n<td>Set register value broadcast interval in milliseconds (e.g., 1000 ms)<\/td>\n<\/tr>\n<tr>\n<td><strong>Receive Timeout (ms)<\/strong><\/td>\n<td>Set timeout threshold for incoming station packets (e.g., 1500 ms)<\/td>\n<\/tr>\n<tr>\n<td><strong>Sync Method<\/strong><\/td>\n<td>Select <strong>Period Sharer<\/strong> (cyclic) or <strong>Write Sharer<\/strong> (event-driven)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\"><strong>Data Mapping Parameters<\/strong><\/h4>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"682\" height=\"807\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/19E09392-1FDF-4FA3-AAD8-6AC7B88D319A.png\" alt=\"\" class=\"wp-image-1109\"><\/figure>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Field<\/strong><\/td>\n<td><strong>Function &amp; Register Range<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Station ID<\/strong><\/td>\n<td>Select target station 0 ~ 15 (hover input boxes to view valid register ranges)<\/td>\n<\/tr>\n<tr>\n<td><strong>Enable Address<\/strong><\/td>\n<td>Control bit to start\/stop station communication (e.g., M0)<\/td>\n<\/tr>\n<tr>\n<td><strong>Status Address<\/strong><\/td>\n<td>Register storing status code: <strong>0<\/strong> = Normal, <strong>1<\/strong> = Duplicate ID, <strong>2<\/strong> = Timeout<\/td>\n<\/tr>\n<tr>\n<td><strong>Share Length Address<\/strong><\/td>\n<td>Set communication index length (maximum 512 words)<\/td>\n<\/tr>\n<tr>\n<td><strong>Timeout Count Address<\/strong><\/td>\n<td>Double register recording cumulative receive timeouts (e.g., DR4)<\/td>\n<\/tr>\n<tr>\n<td><strong>Send\/Receive Count<\/strong><\/td>\n<td>Double register tracking heartbeat packet counter (e.g., DR6)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\"><strong>Data Block &amp; Register Alignment<\/strong><\/h4>\n<p class=\"wp-block-paragraph\">Data mapping register offsets and lengths must match across communicating PLC.<\/p>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"36\" height=\"33\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/B30E0C6F-AF1E-450C-90B2-E5D3CDAF89B3.png\" alt=\"\" class=\"wp-image-1001\"><figcaption class=\"wp-element-caption\"><strong>Add: create new data group<\/strong><\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"40\" height=\"40\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/DD9FB724-1D2A-4267-8AF1-28BA0AC10718.png\" alt=\"\" class=\"wp-image-1002\"><figcaption class=\"wp-element-caption\">DeIete: Remove selected group<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"39\" height=\"35\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/3305B847-EDC8-41D8-B064-E7C20C61FB71.png\" alt=\"\" class=\"wp-image-1003\"><figcaption class=\"wp-element-caption\">Edit: Modify group registers<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"40\" height=\"32\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/DB566DF9-25B2-4149-8B4A-9AA3BD292B52.png\" alt=\"\" class=\"wp-image-1004\"><figcaption class=\"wp-element-caption\">Distribution: View allocated map<\/figcaption><\/figure>\n<h3 class=\"wp-block-heading\">Setting Example<\/h3>\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"685\" height=\"810\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/DC730CCF-F3B6-4C30-83BF-38B45E0BDCF7.png\" alt=\"\" class=\"wp-image-1249\"><\/figure>\n<h3 class=\"wp-block-heading\">Shared Memory Map ExampIe<\/h3>\n<p class=\"wp-block-paragraph\">Each station broadcasts its assigned register block across the LAN to form a unified memory image.<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td>PLC Station A (Satation 0)<\/td>\n<td>PLC Station B (Satation 1 \u3015<\/td>\n<td>PLC Station C (Satation 2\u3015<\/td>\n<\/tr>\n<tr>\n<td>Shares D0~D9<\/td>\n<td>Shares D10~D19<\/td>\n<td>Shares D20~D29<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Required Software &amp; Firmware Ensure all PLC and mod [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[68],"tags":[80,77,79],"class_list":["post-3587","post","type-post","status-publish","format-standard","hentry","category-kb-plc","tag-hmi","tag-mplc","tag-quick-start"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3587"}],"version-history":[{"count":1,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3587\/revisions"}],"predecessor-version":[{"id":3746,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3587\/revisions\/3746"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}