{"id":3691,"date":"2026-11-10T16:43:18","date_gmt":"2026-11-10T08:43:18","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/10\/motion-control-by-plc-registers\/"},"modified":"2026-11-24T11:04:29","modified_gmt":"2026-11-24T03:04:29","slug":"motion-control-by-plc-registers","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/10\/motion-control-by-plc-registers\/","title":{"rendered":"[Motion] Control by PLC Registers"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Note<\/h2>\n<p class=\"wp-block-paragraph\">All registers in this chapter can only be written using the MOV function or the <code>:=<\/code> operator in ST. The register values will be reset to 0 when EtherCAT communication is stopped.<\/p>\n<h2 class=\"wp-block-heading\">Set Current Coordinates<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>M10630<\/strong><\/td>\n<td>SET_CUR_COOR<\/td>\n<td>Set current coordinates<\/td>\n<td>1. When it is triggered, the value of DR37050 is set to the current coordinates <br \/>2. It can only be used when the axis is <mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">not in control <\/mark>or <mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">synchronization mode<\/mark><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37050<\/strong><\/td>\n<td>SET_COOR_VALUE<\/td>\n<td>the coordinates value<\/td>\n<td>1. The unit and decimal place are as defined in the axis table. <br \/>2. Triggering M10630 sets DR37050 to the current coordinate.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Advanced Mode<\/h2>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"596\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/image-11.png\" alt=\"\" class=\"wp-image-764\"><\/figure>\n<h3 class=\"wp-block-heading\">Control bits<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>M10631<\/strong><\/td>\n<td>ADV_MODE_ON<\/td>\n<td>Axis advanced mode on<\/td>\n<td>High: On <br \/>Low: Off<\/td>\n<\/tr>\n<tr>\n<td><strong>M10632<\/strong><\/td>\n<td>ADV_MODE_UNIT_PLS<\/td>\n<td>advanced mode units<\/td>\n<td>High: Pulse unit <br \/>Low: Axis table unit<\/td>\n<\/tr>\n<tr>\n<td><strong>M10633<\/strong><\/td>\n<td>ADV_MODE_COOR_ABS_OR_REF_MASK<\/td>\n<td>advanced mode coordinates<\/td>\n<td>High: Absolute coordinates <br \/>Low: Relative coordinates<\/td>\n<\/tr>\n<tr>\n<td><strong>M11268<\/strong><\/td>\n<td>IS_ADV_ACT<\/td>\n<td>Advanced mode in action<\/td>\n<td>High: In advanced control mode<\/td>\n<\/tr>\n<tr>\n<td><strong>M11269<\/strong><\/td>\n<td>IS_ADV_DN<\/td>\n<td>Advanced mode done<\/td>\n<td>High: Advanced control mode done<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h3 class=\"wp-block-heading\">Parameters (set by fun. MOV or the := operator)<\/h3>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37052<\/strong><\/td>\n<td>SET_ADV_MODE<\/td>\n<td>Choose advanced control mode<\/td>\n<td>1: position control <br \/>2: speed control <br \/>3: torque control <br \/>(Set to 0 before change control mode)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37054<\/strong><\/td>\n<td>SET_ADV_CMD<\/td>\n<td>parameter<\/td>\n<td>Commands when running advanced control mode<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37056<\/strong><\/td>\n<td>SET_ADV_CMD2<\/td>\n<td>parameter 2<\/td>\n<td>Parameter when running advanced control mode<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37058<\/strong><\/td>\n<td>SET_ADV_CMD3<\/td>\n<td>parameter 3<\/td>\n<td>Parameter when running advanced control mode<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37060<\/strong><\/td>\n<td>SET_ADV_CMD4<\/td>\n<td>parameter 4<\/td>\n<td>Parameter when running advanced control mode<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">Position mode (mode 1)<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37052<\/strong><\/td>\n<td>SET_ADV_MODE<\/td>\n<td>control mode<\/td>\n<td><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">1: position control <\/mark><br \/>2: speed control <br \/>3: torque control <br \/>(Set to 0 before change control mode)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37054<\/strong><\/td>\n<td>SET_ADV_CMD<\/td>\n<td>Control Target<\/td>\n<td><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 1, 2, unit follow the unit switch relay <\/mark><br \/>In mode 3, unit is 0.1%<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37056<\/strong><\/td>\n<td>SET_ADV_CMD2<\/td>\n<td>Max Vel<\/td>\n<td><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 1, unit follow the unit switch relay <\/mark><br \/>In mode 2, means torque limit (unit: 0.1%) <br \/>In mode 3, means max speed (unit: RPM)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37058<\/strong><\/td>\n<td>SET_ADV_CMD3<\/td>\n<td>Max Acc<\/td>\n<td>In mode 1, unit follow the unit switch relay Decimal place in axis table<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37060<\/strong><\/td>\n<td>SET_ADV_CMD4<\/td>\n<td>Max Dec<\/td>\n<td>In mode 1, unit follow the unit switch relay Decimal place in axis table Use Max Acc value when Max Dec is 0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">Velocity mode (mode 2)<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37052<\/strong><\/td>\n<td>SET_ADV_MODE<\/td>\n<td>control mode<\/td>\n<td>1: position control <br \/><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">2: speed control <\/mark><br \/>3: torque control <br \/>(Set to 0 before change control mode)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37054<\/strong><\/td>\n<td>SET_ADV_CMD<\/td>\n<td>Control Target<\/td>\n<td><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 1, 2, unit follow the unit switch relay <\/mark><br \/>In mode 3, unit is 0.1%<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37056<\/strong><\/td>\n<td>SET_ADV_CMD2<\/td>\n<td>Max Torque<\/td>\n<td>In mode 1, unit follow the unit switch relay <br \/><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 2, means torque limit (unit: 0.1%) <\/mark><br \/>In mode 3, means max speed (unit: RPM)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37058<\/strong><\/td>\n<td>SET_ADV_CMD3<\/td>\n<td>Max Acc<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37060<\/strong><\/td>\n<td>SET_ADV_CMD4<\/td>\n<td>Max Dec<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h4 class=\"wp-block-heading\">Torque mode (mode 3)<\/h4>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Number<\/strong><\/td>\n<td><strong>TAG Name<\/strong><\/td>\n<td><strong>definition<\/strong><\/td>\n<td><strong>Illustrate<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37052<\/strong><\/td>\n<td>SET_ADV_MODE<\/td>\n<td>control mode<\/td>\n<td>1: position control <br \/>2: speed control <br \/><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">3: torque control<\/mark><br \/>(Set to 0 before change control mode)<\/td>\n<\/tr>\n<tr>\n<td><strong>DR37054<\/strong><\/td>\n<td>SET_ADV_CMD<\/td>\n<td>Control Target<\/td>\n<td>In mode 1, 2, unit follow the unit switch relay <br \/><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 3, unit is 0.1%<\/mark><\/td>\n<\/tr>\n<tr>\n<td><strong>DR37056<\/strong><\/td>\n<td>SET_ADV_CMD2<\/td>\n<td>Max Velocity<\/td>\n<td>In mode 1, unit follow the unit switch relay In mode 2, means torque limit (unit: 0.1%) <br \/><mark style=\"background-color:#fff2cc\" class=\"has-inline-color\">In mode 3, means max speed (unit: RPM)<\/mark><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Note All registers in this chapter can only be written  [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[74],"tags":[91,92,79],"class_list":["post-3691","post","type-post","status-publish","format-standard","hentry","category-kb-m-plc","tag-ethercat","tag-motion","tag-quick-start"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3691"}],"version-history":[{"count":1,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3691\/revisions"}],"predecessor-version":[{"id":3749,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3691\/revisions\/3749"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3691"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3691"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}