{"id":3712,"date":"2026-11-17T17:24:21","date_gmt":"2026-11-17T09:24:21","guid":{"rendered":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/hmi-fatek-hmi-now-supports-bacnet-zh\/"},"modified":"2026-11-17T17:24:21","modified_gmt":"2026-11-17T09:24:21","slug":"hmi-fatek-hmi-now-supports-bacnet-zh","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/17\/hmi-fatek-hmi-now-supports-bacnet-zh\/","title":{"rendered":"[HMI] FATEK HMI \u73fe\u5df2\u652f\u63f4 BACnet"},"content":{"rendered":"<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1268\" height=\"356\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/fatek-p5-bacnet-logo-hq.png\" alt=\"FATEK P5 HMI now supports BACnet\" class=\"wp-image-990\" style=\"aspect-ratio:3.561876787508696;width:436px;height:auto\"><\/figure>\n<p class=\"wp-block-paragraph\">FATEK <strong>P5 \u7cfb\u5217 HMI<\/strong> \u8207 <strong>FvRT<\/strong> \u73fe\u5df2\u5168\u9762\u652f\u63f4 <strong>BACnet<\/strong> \u901a\u8a0a\u5354\u5b9a\uff0c\u4e26\u65b0\u589e\u4e09\u7a2e\u9a45\u52d5\u7a0b\u5f0f\uff1a<strong>BACnet IP Client<\/strong>\u3001<strong>BACnet IP Slave<\/strong> \u8207 <strong>BACnet MS\/TP<\/strong>\u3002\u900f\u904e\u9019\u4e9b\u9a45\u52d5\u7a0b\u5f0f\uff0cP5 HMI \u65e2\u53ef\u4f5c\u70ba\u76e3\u63a7\u7a7a\u8abf\u3001\u7167\u660e\u53ca\u5176\u4ed6\u5efa\u7bc9\u8a2d\u5099\u7684\u64cd\u4f5c\u4ecb\u9762\uff0c\u4e5f\u53ef\u4f5c\u70ba\u53d7\u6a13\u5b87\u7ba1\u7406\u7cfb\u7d71\uff08BMS\uff09\u76e3\u63a7\u7684\u73fe\u5834\u7bc0\u9ede\uff0c\u7121\u9700\u984d\u5916\u9598\u9053\u5668\u5373\u53ef\u9023\u63a5\u667a\u6167\u5efa\u7bc9\u7cfb\u7d71\u3002<\/p>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u4ec0\u9ebc\u662f BACnet\uff1f<\/h2>\n<p class=\"wp-block-paragraph\">BACnet\uff08<em>Building Automation and Control Networks<\/em>\uff09\u662f\u5c08\u70ba\u6a13\u5b87\u81ea\u52d5\u5316\u6240\u5236\u5b9a\u7684\u958b\u653e\u5f0f\u8cc7\u6599\u901a\u8a0a\u5354\u5b9a\u30021987 \u5e74\uff0cASHRAE\uff08\u7f8e\u570b\u51b7\u51cd\u7a7a\u8abf\u5de5\u7a0b\u5e2b\u5b78\u6703\uff09\u6210\u7acb\u7b2c 135 \u865f\u59d4\u54e1\u6703\uff0c\u8457\u624b\u958b\u767c\u4e0d\u9650\u5ee0\u5546\u7684\u5efa\u7bc9\u7cfb\u7d71\u901a\u8a0a\u5354\u5b9a\u3002BACnet \u65bc 1995 \u5e74\u767c\u5e03\u70ba ANSI\/ASHRAE Standard 135\uff0c\u4e26\u65bc 2003 \u5e74\u6210\u70ba\u570b\u969b\u6a19\u6e96 <strong>ISO 16484-5<\/strong>\uff0c\u8a72\u59d4\u54e1\u6703\u6301\u7e8c\u7dad\u8b77\u4e26\u66f4\u65b0\u6b64\u6a19\u6e96\u3002<\/p>\n<p class=\"wp-block-paragraph\">BACnet \u7684\u4e3b\u8981\u512a\u52e2\u5728\u65bc<strong>\u4e92\u901a\u6027<\/strong>\u3002\u4e0d\u540c\u5ee0\u724c\u7684\u63a7\u5236\u5668\u3001\u611f\u6e2c\u5668\u8207\u76e3\u63a7\u7cfb\u7d71\u53ef\u5728\u540c\u4e00\u7db2\u8def\u4e0a\u4ea4\u63db\u8cc7\u6599\uff0c\u8b93\u696d\u4e3b\u4e0d\u53d7\u55ae\u4e00\u5ee0\u5546\u7d81\u5b9a\u3002\u76ee\u524d BACnet \u5df2\u5ee3\u6cdb\u61c9\u7528\u65bc\u7a7a\u8abf\u3001\u7167\u660e\u3001\u9580\u7981\u3001\u6d88\u9632\u8207\u4fdd\u5168\u7cfb\u7d71\uff0c\u4ee5\u53ca\u80fd\u6e90\u7ba1\u7406\u3002<\/p>\n<h3 class=\"wp-block-heading\">BACnet \u904b\u4f5c\u65b9\u5f0f\uff1a\u7269\u4ef6\u3001\u5c6c\u6027\u8207\u670d\u52d9<\/h3>\n<ul class=\"wp-block-list\">\n<li><strong>\u7269\u4ef6\uff08Objects\uff09<\/strong> \u2013 BACnet \u88dd\u7f6e\u4e2d\u7684\u6bcf\u500b\u8cc7\u6599\u9ede\u90fd\u662f\u4e00\u500b\u7269\u4ef6\uff0c\u4f8b\u5982\u985e\u6bd4\u8f38\u5165\uff08\u5982\u6eab\u5ea6\u611f\u6e2c\u5668\uff09\u3001\u4e8c\u9032\u4f4d\u8f38\u51fa\uff08\u5982\u98a8\u6247\u555f\u505c\u6307\u4ee4\uff09\u3001\u6392\u7a0b\u6216\u8da8\u52e2\u8a18\u9304\u3002\u6a19\u6e96\u7b2c\u4e00\u7248\u5b9a\u7fa9\u4e86 18 \u7a2e\u7269\u4ef6\u985e\u578b\uff0c\u5f8c\u7e8c\u7248\u672c\u5df2\u5b9a\u7fa9\u8d85\u904e 60 \u7a2e\u3002<\/li>\n<li><strong>\u5c6c\u6027\uff08Properties\uff09<\/strong> \u2013 \u6bcf\u500b\u7269\u4ef6\u7531\u5c6c\u6027\u4f86\u63cf\u8ff0\u3002\u6bcf\u500b\u7269\u4ef6\u90fd\u5177\u6709 Object_Identifier\u3001Object_Name \u8207 Object_Type\uff0c\u6700\u5e38\u7528\u7684\u5c6c\u6027\u662f <em>Present_Value<\/em>\uff0c\u7528\u4f86\u5b58\u653e\u5373\u6642\u8b80\u503c\u6216\u6307\u4ee4\u503c\u3002<\/li>\n<li><strong>\u670d\u52d9\uff08Services\uff09<\/strong> \u2013 \u670d\u52d9\u662f BACnet \u88dd\u7f6e\u4e4b\u9593\u4e92\u76f8\u767c\u9001\u7684\u8acb\u6c42\u3002\u4f8b\u5982\u7528\u65bc\u8cc7\u6599\u4ea4\u63db\u7684 <em>ReadProperty<\/em> \u8207 <em>WriteProperty<\/em>\u3001\u7528\u65bc\u88dd\u7f6e\u63a2\u7d22\u7684 <em>Who-Is \/ I-Am<\/em>\uff0c\u4ee5\u53ca\u7528\u65bc\u8b66\u5831\u8207\u4e8b\u4ef6\u3001\u6a94\u6848\u5b58\u53d6\u548c\u9060\u7aef\u88dd\u7f6e\u7ba1\u7406\u7684\u670d\u52d9\u3002<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u4e3b\u8981\u61c9\u7528<\/h2>\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1150\" height=\"1316\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/fatek-p5-bacnet-building-hq.png\" alt=\"BACnet building automation: HVAC, ventilation and facility monitoring\" class=\"wp-image-991\" style=\"aspect-ratio:0.8738692609660351;width:443px;height:auto\"><\/figure>\n<ul class=\"wp-block-list\">\n<li>\u4e3b\u8981\u7528\u65bc<strong>\u667a\u6167\u5efa\u7bc9\u8207\u6a13\u5b87\u81ea\u52d5\u5316<\/strong><\/li>\n<li>\u76e3\u63a7<strong>\u7a7a\u8abf\u3001\u6eab\u5ea6\u3001\u6fd5\u5ea6\u3001\u7167\u660e\u3001\u80fd\u6e90\u53ca\u8a2d\u5099\u72c0\u614b<\/strong><\/li>\n<li>\u5178\u578b\u5834\u6240\uff1a<strong>\u5de5\u5ee0\u3001\u6a5f\u623f\u3001\u8cc7\u6599\u4e2d\u5fc3\u3001\u91ab\u9662\u3001\u6a5f\u5834\u3001\u5b78\u6821\u53ca\u5546\u696d\u8fa6\u516c\u5927\u6a13<\/strong><\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u4e09\u7a2e BACnet \u9a45\u52d5\u7a0b\u5f0f\uff0c\u6574\u5408\u66f4\u9748\u6d3b<\/h2>\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1038\" height=\"1014\" src=\"https:\/\/resource.fatek.com\/wp-content\/uploads\/2026\/11\/fatek-p5-bacnet-architecture-hq.png\" alt=\"FATEK P5 HMI as BACnet IP Client and BACnet IP Slave: system architecture\" class=\"wp-image-992\" style=\"aspect-ratio:1.023681521304483;width:540px;height:auto\"><figcaption class=\"wp-element-caption\">P5 HMI \u5728\u6a13\u5b87\u81ea\u52d5\u5316\u7cfb\u7d71\u4e2d\u4f5c\u70ba BACnet IP Client \u8207 BACnet IP Slave<\/figcaption><\/figure>\n<h3 class=\"wp-block-heading\">1. BACnet IP Client \u9a45\u52d5\u7a0b\u5f0f<\/h3>\n<p class=\"wp-block-paragraph\">\u4f5c\u70ba Client \u6642\uff0cP5 HMI \u6703\u900f\u904e\u4e59\u592a\u7db2\u8def\u4e3b\u52d5\u8b80\u53d6\u53ca\u5beb\u5165 BACnet \u73fe\u5834\u88dd\u7f6e\uff0c\u4e26\u6210\u70ba\u6574\u500b\u5efa\u7bc9\u7cfb\u7d71\u7684\u64cd\u4f5c\u756b\u9762\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u63a7\u5236\u7a7a\u8abf\u7bb1\u3001\u51b0\u6c34\u6a5f\u3001\u7167\u660e\u53ca VAV \u7bb1\u7b49\u73fe\u5834\u8a2d\u5099<\/li>\n<li>\u76e3\u63a7\u4e26\u6536\u96c6\u6eab\u5ea6\u3001\u6fd5\u5ea6\u53ca CO\u2082 \u7b49\u611f\u6e2c\u5668\u6578\u503c<\/li>\n<li>\u5411 Slave \u88dd\u7f6e\u4e0b\u9054\u6307\u4ee4\uff0c\u5354\u8abf\u6574\u68df\u5efa\u7bc9\u7684\u81ea\u52d5\u5316\u904b\u4f5c<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">2. BACnet IP Slave \u9a45\u52d5\u7a0b\u5f0f\uff08\u65b0\u589e\uff09<\/h3>\n<p class=\"wp-block-paragraph\">\u4f5c\u70ba\u4f3a\u670d\u5668\uff08Slave\uff09\u88dd\u7f6e\u6642\uff0cP5 HMI \u6703\u5c07\u5176\u8cc7\u6599\u63d0\u4f9b\u7d66\u4e0a\u5c64\u7cfb\u7d71\uff0c\u8b93\u73fe\u5834\u6a5f\u53f0\u6216\u63a7\u5236\u76e4\u53ef\u76f4\u63a5\u52a0\u5165\u65e2\u6709\u7684 BMS\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u53d7 SCADA \u6216 BMS \u7b49\u4e0a\u5c64\u7cfb\u7d71\u76e3\u63a7<\/li>\n<li>\u4f5c\u70ba\u73fe\u5834\u63a7\u5236\u7bc0\u9ede\uff0c\u57f7\u884c\u4e3b\u7ad9\u4e0b\u9054\u7684\u6307\u4ee4<\/li>\n<li>\u6536\u96c6\u4e26\u56de\u5831\u611f\u6e2c\u5668\u6578\u503c\u8207\u8a2d\u5099\u72c0\u614b<\/li>\n<\/ul>\n<h3 class=\"wp-block-heading\">3. BACnet MS\/TP \u9a45\u52d5\u7a0b\u5f0f<\/h3>\n<p class=\"wp-block-paragraph\">BACnet MS\/TP\uff08Master-Slave\/Token-Passing\uff09\u904b\u884c\u65bc <strong>RS-485<\/strong> \u4e32\u5217\u532f\u6d41\u6392\uff0c\u662f\u4e00\u7a2e\u4f4e\u6210\u672c\u7684\u914d\u7dda\u65b9\u5f0f\uff0c\u5e38\u898b\u65bc\u73fe\u5834\u5c64\u7d1a\u7684\u6a13\u5b87\u63a7\u5236\u5668\u3002\u642d\u914d MS\/TP \u9a45\u52d5\u7a0b\u5f0f\uff0cP5 HMI \u975e\u5e38\u9069\u5408\u7528\u65bc\uff1a<\/p>\n<ul class=\"wp-block-list\">\n<li>\u5340\u57df\u6027\u63a7\u5236<\/li>\n<li>\u9023\u63a5\u50c5\u6709\u4e32\u5217\u57e0\u7684\u820a\u8a2d\u5099<\/li>\n<li>\u7279\u6b8a\u7684\u5d4c\u5165\u5f0f\u6574\u5408<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">BACnet\/IP \u8207 BACnet MS\/TP \u6bd4\u8f03<\/h2>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th><\/th>\n<th>BACnet\/IP<\/th>\n<th>BACnet MS\/TP<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u5be6\u9ad4\u5c64<\/td>\n<td>\u4e59\u592a\u7db2\u8def<\/td>\n<td>RS-485 \u4e32\u5217<\/td>\n<\/tr>\n<tr>\n<td>\u50b3\u8f38\u5c64<\/td>\n<td>UDP\/IP\uff0c\u9810\u8a2d Port 47808\uff080xBAC0\uff09<\/td>\n<td>Token-passing \u4e32\u5217\u532f\u6d41\u6392<\/td>\n<\/tr>\n<tr>\n<td>\u5178\u578b\u901f\u7387<\/td>\n<td>10\/100\/1000 Mbps<\/td>\n<td>9,600 \u2013 115,200 bps<\/td>\n<\/tr>\n<tr>\n<td>\u62d3\u64b2<\/td>\n<td>\u4ea4\u63db\u5f0f\u4e59\u592a\u7db2\u8def<\/td>\n<td>\u83ca\u934a\u5f0f\u532f\u6d41\u6392<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u5740\u65b9\u5f0f<\/td>\n<td>IP \u4f4d\u5740 + UDP Port<\/td>\n<td>MAC \u4f4d\u5740\uff08Master \u70ba 0\u2013127\uff09<\/td>\n<\/tr>\n<tr>\n<td>\u5178\u578b\u7528\u9014<\/td>\n<td>\u76e3\u63a7\u7cfb\u7d71\u3001BMS \u5de5\u4f5c\u7ad9\u3001IP \u63a7\u5236\u5668<\/td>\n<td>\u73fe\u5834\u63a7\u5236\u5668\u3001VAV \u7bb1\u3001\u820a\u8a2d\u5099<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u6574\u5408\u5efa\u8b70<\/h2>\n<ul class=\"wp-block-list\">\n<li><strong>\u4f7f\u7528\u552f\u4e00\u7684 Device Instance\uff1a<\/strong>\u7db2\u8def\u4e0a\u6bcf\u500b BACnet \u88dd\u7f6e\u90fd\u9700\u8981\u7368\u7acb\u7684 Device Instance \u7de8\u865f\uff080 \u2013 4,194,302\uff09\u3002<\/li>\n<li><strong>\u958b\u653e UDP Port 47808\uff1a<\/strong>BACnet\/IP \u9810\u8a2d\u4f7f\u7528 UDP Port 47808\u3002\u8acb\u78ba\u8a8d\u9632\u706b\u7246\u8207 VLAN \u8a2d\u5b9a\u5141\u8a31 HMI \u8207 BACnet \u88dd\u7f6e\u4e4b\u9593\u4f7f\u7528\u6b64 Port\uff0c\u4e14\u96d9\u65b9\u4f7f\u7528\u76f8\u540c\u7684 Port \u7de8\u865f\u3002<\/li>\n<li><strong>\u898f\u5283\u8de8\u5b50\u7db2\u8def\u67b6\u69cb\uff1a<\/strong>\u88dd\u7f6e\u63a2\u7d22\uff08Who-Is \/ I-Am\uff09\u4f7f\u7528\u5ee3\u64ad\u8a0a\u606f\uff0c\u800c\u5ee3\u64ad\u7121\u6cd5\u8de8\u8d8a IP \u8def\u7531\u5668\u3002\u7576\u88dd\u7f6e\u4f4d\u65bc\u4e0d\u540c\u5b50\u7db2\u8def\u6642\uff0c\u901a\u5e38\u9700\u8981 BBMD\uff08BACnet Broadcast Management Device\uff09\u3002<\/li>\n<li><strong>MS\/TP \u4e32\u5217\u8a2d\u5b9a\u9808\u4e00\u81f4\uff1a<\/strong>\u5728 MS\/TP \u532f\u6d41\u6392\u4e0a\uff0c\u6bcf\u500b\u88dd\u7f6e\u90fd\u9700\u8981\u552f\u4e00\u7684 MAC \u4f4d\u5740\uff0c\u4e14\u6240\u6709\u88dd\u7f6e\u5fc5\u9808\u4f7f\u7528\u76f8\u540c\u7684\u9b91\u7387\u3002<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u652f\u63f4\u7684\u8edf\u9ad4\u7248\u672c<\/h2>\n<p class=\"wp-block-paragraph\">BACnet \u9a45\u52d5\u7a0b\u5f0f\u81ea\u4e0b\u5217\u8edf\u9ad4\u7248\u672c\u8d77\u63d0\u4f9b\uff1a<\/p>\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr>\n<th>\u901a\u8a0a\u5354\u5b9a<\/th>\n<th>\u4ecb\u9762<\/th>\n<th>\u8edf\u9ad4\u7248\u672c<\/th>\n<th>\u5099\u8a3b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>BACnet IP<\/td>\n<td>\u4e59\u592a\u7db2\u8def<\/td>\n<td>V1.6.78<br \/>V1.7.03<\/td>\n<td>BACnet Honeywell<\/td>\n<\/tr>\n<tr>\n<td>BACnet IP Slave<\/td>\n<td>\u4e59\u592a\u7db2\u8def<\/td>\n<td>V1.6.93<br \/>V1.7.11<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>BACnet MS\/TP<\/td>\n<td>\u4e32\u5217<\/td>\n<td>V1.6.78<br \/>V1.7.03<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\" style=\"font-size:clamp(27.894px, 1.743rem + ((1vw - 3.2px) * 1.971), 48px);\">\u7d50\u8ad6<\/h2>\n<p class=\"wp-block-paragraph\">BACnet \u662f\u73fe\u4ee3\u6a13\u5b87\u81ea\u52d5\u5316\u7684\u5171\u901a\u8a9e\u8a00\u3002FATEK P5 HMI \u65e2\u53ef\u4f5c\u70ba\u6a13\u5b87\u63a7\u5236\u4e2d\u5fc3\u7684\u64cd\u4f5c\u4ecb\u9762\uff0c\u4e5f\u53ef\u4f5c\u70ba\u53d7 BMS \u7ba1\u7406\u7684\u73fe\u5834\u7bc0\u9ede\u3002\u6191\u85c9\u4e09\u7a2e\u9a45\u52d5\u7a0b\u5f0f\uff08BACnet IP Client\u3001BACnet IP Slave \u8207 BACnet MS\/TP\uff09\uff0c\u4e0d\u8ad6\u662f\u65b0\u5efa\u7684 IP \u67b6\u69cb\u5c08\u6848\uff0c\u6216\u662f\u65e2\u6709\u4e32\u5217\u7cfb\u7d71\u7684\u5347\u7d1a\uff0c\u90fd\u80fd\u6db5\u84cb\u3002\u5982\u9700\u9032\u4e00\u6b65\u4e86\u89e3 BACnet \u89e3\u6c7a\u65b9\u6848\uff0c\u8acb\u806f\u7d61 FATEK \u6216\u7576\u5730\u7d93\u92b7\u5546\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>FATEK P5 \u7cfb\u5217 HMI \u8207 FvRT \u73fe\u5df2\u5168\u9762\u652f\u63f4 BACnet \u901a\u8a0a\u5354\u5b9a\uff0c\u4e26\u65b0\u589e\u4e09\u7a2e\u9a45\u52d5\u7a0b\u5f0f\uff1aBAC [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[69,75],"tags":[],"class_list":["post-3712","post","type-post","status-publish","format-standard","hentry","category-kb-hmi","category-kb-p5-p2"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3712","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3712"}],"version-history":[{"count":0,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3712\/revisions"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3712"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3712"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}