{"id":3780,"date":"2026-11-26T14:27:06","date_gmt":"2026-11-26T06:27:06","guid":{"rendered":"https:\/\/resource.fatek.com\/?p=3780"},"modified":"2026-11-26T16:50:11","modified_gmt":"2026-11-26T08:50:11","slug":"mplcethercat-handwheel-quick-start","status":"publish","type":"post","link":"https:\/\/resource.fatek.com\/index.php\/2026\/11\/26\/mplcethercat-handwheel-quick-start\/","title":{"rendered":"[MPLC] EtherCat Handwheel Quick Start"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In this example, Axis 1 is used as the synchronized axis for the handwheel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Motion Link Configuration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Add an SC3 Real Axis.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/9A68F369-1687-43BA-A72B-F01E3BA5BD16-1024x548.png\" alt=\"\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If the real axis option is not available in the ToolBox, you can import the real axis ESI file to add it.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/118242D4-A927-4FCF-976C-4B60E8A48E0C-1024x552.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Motion Axis Configuration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Configure the basic parameters for each axis.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/AFA46BFC-C56B-4DEC-8880-29054DCA8469-1024x548.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Auto-Initialization + Servo ON at Power-Up<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1.Use <strong>Fun187<\/strong> to initialize the servo drives.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2.Use <strong>M10520<\/strong> to enable (Servo ON) all servo drives. You can refer to the Ladder logic example below:<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/4447E66A-10C6-487F-AAF9-3B9E11179C9F-1024x542.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Handwheel DI Input Configuration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Currently, EtherCAT handwheel inputs can only use <strong>X8~X15<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Configure High-Speed Counters <strong>HSC4~HSC7<\/strong> first:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>I\/O Configuration &gt; High Speed Counter &gt; HSC4~HSC7<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Currently, HSC4~HSC7 only support <strong>A\/B*4<\/strong> mode. Note that A\/B*4 multiplies the output pulse count by 4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HSC4<\/strong> = External Reference No. 1, <strong>HSC5<\/strong> = External Reference No. 2, and so on. These numbers will be used later in the Synchronization Parameters.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/214FA5CD-DCC9-49D2-934A-9E3A1CB73280-1024x544.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Start Axis Synchronization Using Motion Flow<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Add a new <strong>Motion Flow<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Insert a <strong>Sync Control<\/strong> block and select the axis to be synchronized with the handwheel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use a <strong>Wait<\/strong> condition to hold the flow; once the condition is met, the flow proceeds downward to disable synchronization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this example, when <strong>M200 = 0<\/strong>, synchronization is disabled and the Motion Flow ends.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/764CF47D-70C1-4EFC-AABF-B3C1973FC283-1024x548.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Start Motion Flow Using Fun176<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The example below uses <strong>Fun176<\/strong> to start Motion Flow <strong>ID: 1<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this example, setting <strong>M200 = 1<\/strong> starts the Motion Flow, working together with the Wait condition inside the flow to stop synchronization when needed.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/6AC6B4F3-F0A0-4FD6-A54D-062689B16442-1024x548.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Synchronization Parameters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Synchronization Parameters &gt;<\/strong> Select the <strong>&#8220;Output Axis&#8221;<\/strong> to be synchronized with the handwheel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Basic Setting &gt;<\/strong> Set the unit according to the unit of the output axis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Basic Setting &gt;<\/strong> Keep the default <strong>Master Cycle<\/strong> of <code>1000 mm<\/code> mapped to the <strong>Slave Cycle<\/strong> of <code>1000 mm<\/code>. The output axis will travel the exact same distance as the input axis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Master Input &gt;<\/strong> <strong>HSC4<\/strong> = External Reference No. 1, <strong>HSC5<\/strong> = External Reference No. 2, and so on.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Master Input &gt;<\/strong> Set <strong>&#8220;Coordinate Conversion Setting&#8221;<\/strong> to <strong>&#8220;By Sync Parameter&#8221;<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The handwheel input pulses are converted into unit travel distance via the &#8220;Coordinate Conversion Setting&#8221;:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/image-164.png\" alt=\"\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The unit travel distance is then mapped from the Master Cycle to the Slave Cycle.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Example:<\/strong> Suppose the handwheel inputs 32,768 pulses:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/image-166.png\" alt=\"\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/F0C0AA6F-A48C-4F87-986A-1B53BCB6FE9E.png\" alt=\"\"\/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">This equals a Master Input of <code>100 mm<\/code>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/0E4BB2CF-263B-45E9-B5A6-DBB04359D621-1024x544.png\" alt=\"\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/forum.fatek.com\/wp-content\/uploads\/2026\/11\/0594B825-F173-4634-B962-ED9A45C801E3-1024x552.png\" alt=\"\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Run the PLC<\/h3>\n\n\n\n<ol start=\"1\" id=\"p-rc_0044c521a31d5bbc-60\" class=\"wp-block-list\">\n<li>Switch the PLC DIP switch to <strong>RUN<\/strong>.<\/li>\n\n\n\n<li>Set <strong>M200 = 1<\/strong> to trigger <strong>Fun176<\/strong>, starting Flow 1 and initiating synchronization.<\/li>\n\n\n\n<li>Input pulses via the handwheel.<\/li>\n\n\n\n<li>Axis 1 rotates in a 1:1 ratio following the handwheel.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this example, Axis 1 is used as the synchronized axi [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[74],"tags":[],"class_list":["post-3780","post","type-post","status-publish","format-standard","hentry","category-kb-m-plc"],"_links":{"self":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/comments?post=3780"}],"version-history":[{"count":2,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3780\/revisions"}],"predecessor-version":[{"id":3784,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/posts\/3780\/revisions\/3784"}],"wp:attachment":[{"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/media?parent=3780"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/categories?post=3780"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/resource.fatek.com\/index.php\/wp-json\/wp\/v2\/tags?post=3780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}