# FATEK Resource Hub > FATEK 永宏電機 PLC、HMI 與自動化產品技術手冊資源中心|FATEK Automation technical manuals FATEK Automation Corp.(永宏電機)官方技術手冊資源中心。每篇文章為產品手冊的一個章節,內容包含 PLC、HMI、伺服與相關自動化產品的硬體規格、安裝、指令與應用說明。 Official technical manual hub of FATEK Automation Corp. Each article is one chapter of a product manual (PLC, HMI, servo and related automation products). - Website: https://resource.fatek.com/ - Sitemap: https://resource.fatek.com/sitemap.xml - Company: https://www.fatek.com/ ## Binary Communication Protocol User Manual - [Message](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-en-01/): 1. MessageM series PLC is defined as slaves in the communication with peripheral devices that are always defined as mast - [Payload](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-en-02/): 2. Payload2.1. FormatQueryHeaderIDLengthSTN(1)CMD(1)DATA(n)CRCTerminatorResponseHeaderIDLengthSTN(1)CMD(1)ERR(1)DATA (n) ## CPU Unit User Manual - [CPU Interface and Peripheral Functions](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-05/): CPU Interface and Peripheral Functions5-1 Instructions for CPU Panel Interface and Functions5-1-1 Advanced type Module C - [End Module](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-08/): End ModuleThree views of the end module8-1 Specifications and FunctionsThe End Module should be connected to the rightmo - [Hardware Installation and Wiring](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-10/): Hardware Installation and WiringCaution- The installation that the safety of any system incorporating the equipment is t - [M-Series PLC Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-06/): M-Series PLC Specifications6-1 General SpecificationsItemME,MS,MUMA,MQPower consumptionDC24V±20%,0.2ADC24V±20%,0.15AGrou - [Maintenance and Inspections](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-11/): Maintenance and Inspections11-1 Operating InstructionsWhen executing the servicing and maintenance, please observe the f - [Overview](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-01/): Overview1-1 OverviewCategoryModelMaximum I/O PointsTotal Program MemoryBuilt-inEthernetCommunication HSC HSPOTotalAxesPu - [Power Supply Wiring & Power Consumption Calculation and Power Sequenci](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-07/): 7 Power Supply Wiring & Power Consumption Calculation and Power Sequencing Requirements Power Supply Wiring & Po - [Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-00/): Manual for FATEK M-Series PLC CPU Module Hardware PrefaceThis Manual provides important information related to the use o - [Product Line](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-02/): Product LineFATEK M-Series PLC is designed as a modularized PLC product that is provided with custom-made, flexible expa - [Quick installation steps](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-09/): Steps of Quick InstallationThis section describes the operating steps under normal conditions. - [Revision History](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-12/): VersionRevision dateRevision contentV1.0.02024/12/30first editionV1.0.12025/01/10Change 2-2.3-4.3-1 pictureV1.0.22025/11 - [System Configuration](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-03/): System ConfigurationThis section describes the precautions when installing the basic system as well as the content relat - [UperLogic](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-en-04/): UperLogicThe “UperLogic” is the name of logic edit and test application software that will be used with FATEK M-Series P ## CPU 單元使用手冊 - [前言](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-00/): 前言本手冊用於說明使用FATEK M系列PLC CPU 模組時之必要資訊,請在使用本產品前閱讀並確實瞭解本手冊之內容後再行使用。如若有任何疑問或意見,請洽詢FATEK代理經銷商保固內容和責任限制。保固內容FATEK的產品保固期是指產品自售出 - [第10章 硬體安裝與接線](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-10/): 注意- The installation that the safety of any system incorporating the equipment is the responsibility of the assembler of - [第11章 維護與檢查](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-11/): 11-1 注意事項進行各項維護保養時,請注意以下事項,錯誤或不慎的操作將可能造成人員與設備的傷害。 在維護過程中,需要接觸到PLC之任何端子,或插入、拔取零組件(如擴充排線等)均需切斷PLC之輸入電源,如在通電中進行,將可能造成觸電、短路、 - [第1章 總覽](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-01/): 1-1 概述本章將介紹M系列PLC各模組的型號。分類型號最大本地 I/O專案記憶體內建*4乙太網路通訊HSCHSPO控制總數脈衝EtherCATDIOAIOPLCMotion數量數量3D圓弧/螺旋補間電子凸輪精選型CPU模組EtherCAT - [第2章 產品陣容](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-02/): 永宏M系列PLC為一模組化PLC產品,具備客製化、彈性擴充、靈活調整特性。實現世界最輕巧極致PLC的展現,結合控制、軸控、通訊、蒐集、物連網功能於一台輕巧機體當中。M系列模組圖2-1 產品特色模組之間可以直接連接通過模組側面配備的連接埠,模 - [第3章 系統配置](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-03/): 在本章中,說明對基本系統配置時的注意事項、外圍設備有關內容進行說明。3-1 基本系統配置您可以在M系列PLC CPU模組右側增加M系列模組以搭配不同的應用方式。可使用的模組包括數位I/O模組、類比I/O模組、溫度模組、網路模組、荷重模組等。 - [第4章 UperLogic](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-04/): “UperLogic”為用於FATEK M系列PLC的邏輯編輯及測試應用軟體的名稱,可用於PLC邏輯編輯、網路設定、伺服控制、溫度控制及其他功能。UperLogic功能圖4-1 連接方法可透過TYPE-C數據連接線或RJ45網路連接線直接連 - [第5章 CPU模組介面和週邊功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-05/): 5-1 CPU模組面板介面和功能說明5-1-1 高功能型模組高功能型的CPU模組圖編號名稱功能1.USB連接埠用於連接 Type C數據連接線。2.記憶卡插槽插入永宏MicroSD記憶卡用的插槽。3.RUN/STOP轉換開關切換 RUN 模 - [第6章 M系列PLC規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-06/): 6-1 一般規格項目ME、MS、MU 系列 MA、MQ 系列電源消耗DC24V±20%,0.2ADC24V±20%,0.15A接地要求D類接地(第3種接地)使用環境工作環境溫度0~55℃工作環境濕度5~95%RH(不可結露,RH-2)工作大 - [第7章 電源供應器配線&功率消耗計算及電源時序要求](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-07/): M系列PLC電源模組有兩種電源,第一為CPU專用之24VDC電源(供給CPU模組和擴充模組),第二為外部Sensor 之24VDC電源。CPU模組和擴充模組也分為兩種電路,第一為內部24VDC電路,第二為外部24VDC Sensor電路。內 - [第8章 終端模組](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-08/): 終端模組三視圖8-1 終端模組規格與功能請連接在MPLC系列主機或擴充模組的最右側,有使用I/O Bus延伸模組時,擴展區的最右側也需安裝終端模組。不連接時會發生錯誤,無法正常動作。 - [第9章 快速上手](https://resource.fatek.com/index.php/2026/11/17/mplc-m01-zh-09/): 此章節將會說明通常情況下的操作步驟。 ## Expansion Module Specification Manual - [Amendment record](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-21/): VersionDateDescriptionV1.02024/12/20DraftV1.12024/12/20Plug-in Expansion Boards & Expansion modules applicationV1.22 - [Chapter 1 Expansion Modules](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-01/): List of Expansion ModulesCategoryModelSpecificationsPower ExpansionPower Supply ModuleMPA024-24Input: 100~240VAC(50/60Hz - [Chapter 10 Local I O Expansion Modules Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-10/): Chapter 10 Local I/O Expansion Modules Specifications10-1 Digital Input Expansion Module SpecificationsIf the input poin - [Chapter 11 Peripheral and Accessory](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-11/): 11-1 M PLC Dedicated Micro SD Card11-1-1 MFM06 SpecificationsAppearance and Function MFM06 Technical SpecificationMFM06 - [Chapter 12 Plug-in Expansion Boards application](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-12/): 12-1 Digital input Plug-in Module Specifications12-1-1 MB-4XThis is a digital input plug-in module for the MQ model. It - [Chapter 13 Expansion modules application](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-13/) - [Chapter 14 Register Settings](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-14/): 14-1 Control WordUse the control word to read and write the register of parameters or monitor the status.Type and RangeR - [Chapter 15 Advanced Expansion & Power Modules Dimensions](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-15/): 15-1 Power Module Dimensions15-1-1 MPA024-24 DimensionsMPA024-24 Dimensions15-1-2 MPA048-24 DimensionsMPA048-24 Dimensio - [Chapter 16 High Speed Expansion Modules Dimensions](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-16/): 16-1 High Speed Communication Expansion Module Dimensions16-1-1 MHCM22 DimensionsMHCM22 Dimensions16-1-2 MHCM55 Dimensio - [Chapter 17 Local I O Expansion Modules Dimensions](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-17/): Chapter 17 Local I/O Expansion Modules Dimensions17-1 Digital input Expansion Module Dimensions17-1-1 M16X DimensionsM16 - [Chapter 18 I O Bus Extension Modules Dimensions](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-18/): Chapter 18 I/O Bus Extension Modules Dimensions18-1 Repeater Expansion Module Dimensions18-1-1 MRPWE-AC DimensionsMRPWE- - [Chapter 19 Peripheral and Accessory Dimensions](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-19/): 19-1 DIO Converter Module Dimensions19-1-1 MFT40T DimensionsMFT40T Dimensions19-2 High-Density DIO Cable Dimensions19-2- - [Chapter 2 Expansion of M Series PLC](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-02/): The expansion of M series PLC means when the resources provided by the M series CPU module are insufficient or the inter - [Chapter 20 Repairs and Maintenance](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-20/): 20-1 PrecautionsWhen performing the required servicing and maintenance, please watch the following requirements because - [Chapter 3 Installation And Wiring](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-03/): ⚠DangerTurn off all power before installation of M Series PLC or related equipments to prevent electric shock or damage - [Chapter 4 Power Module Wiring, Power Consumption Calculation, and Powe](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-04/): Chapter 4 Power Module Wiring, Power Consumption Calculation, and Power Sequence RequirementsThere are two kinds of powe - [Chapter 5 Digital Input Circuit](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-05/): M Series PLC provides the single end 24VDC inputs which use the common terminal to save terminals. The response speeds o - [Chapter 6 Digital Output Circuit](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-06/): 6-1 Digital Output Circuit SpecificationsDigital Output Circuit SpecificationsItemSpecificationSingle-End Transistor Out - [Chapter 7 Advanced Expansion & Power Modules Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-07/): 7-1 Power Module Specifications7-1-1 MPA024-24 SpecificationAppearance and FunctionMPA024-24部位名稱Technical Specifications - [Chapter 8 Plug-in Expansion Boards Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-08/): 8-1 Communication Plug-in Expansion Boards SpecificationsIf the communication Port of the M Series CPU module is not eno - [Chapter 9 High-Speed Expansion Modules Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-09/): 9-1 High Speed Communication Expansion Module SpecificationsIf the communication Port of the M Series CPU module is not - [Precautions on using the product](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-en-00/): Compliance with the application-related conditionsThe user shall evaluate the suitability of FATEK product and shall ins ## FBs Compare Manual - [Digital and Register](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-en-01/): 1-1 Digital and Register Configuration ReferenceDigital and Register Configuration ReferenceTypeItemM PLC Specifications - [Function Comparison](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-en-03/): 3-1 Modbus Address Mapping TableComponent NameM PLCFBSDevice RangeModbus Address RangeDevice RangeModbus Address RangeCo - [Precautions on Using the Product](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-en-00/): Compliance with the application-related conditionsThe user shall evaluate the suitability of FATEK product and shall ins - [Revision History](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-en-04/): VersionRevision DateRevision ContentV1.02026/05/20First EditionV1.0.02026/5/28Added Section 1-1 (Pages 1-2)V1.0.12026/6/ - [Special Register Reference](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-en-02/): 2-1 Special Register ReferenceSpecial Register ReferenceMPLC RelayWrite PermissionsFBS RelayRelay No.FunctionLable Abbre ## FBs 比較手冊 - [使用本產品注意事項](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-zh-00/): 符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所使用的系統、機械或是裝置是否適用於FATEK產品。如未確認是否符合或適用時,本公司無須對產品的適用性負責。如客戶要求,FATEK 將提供相應的第 - [修訂紀錄](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-zh-04/): 版本修訂日期修訂內容V1.02026/05/20初版V1.0.02026/5/28新增1-1 ( 1-2頁 )V1.0.12026/6/11新增2-1 ( 2-2 ~ 2-12頁 )V1.0.22026/6/18新增2-1(2-12~2-1 - [第1章 接點及暫存器比較](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-zh-01/): 1-1 接點及暫存器比較表接點及暫存器比較表類型項目M PLC範圍FBs範圍M PLC 數量FBs 數量X輸入接點X0 – X1023X0 – X2551024256Y輸出繼電器Y0 – Y1023Y0 – Y2551024256M內部繼電 - [第2章 特殊暫存器比較表](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-zh-02/): 2-1 特殊繼電器比較表特殊繼電器比較表MPLC繼電器讀寫權限FBS繼電器編號功能標籤簡寫說明編號功能說明停 機 , 禁止 控 制M9120緊急停機控制EMERGENCY_STOP_CTRL1:PLC停止RWM1912緊急停機控制1:PLC - [第3章 功能比較](https://resource.fatek.com/index.php/2026/11/17/mplc-m10-zh-03/): 3-1 Modbus 位址對應表元件名稱M PLCFBS元件範圍Modbus 位址範圍元件範圍Modbus 位址範圍接點設定輸出繼電器 [Y]Y0 - Y1023000001−001024Y0 - Y255000001 - 000256輸入 ## Function and Application User Manual - [Amendment Record](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-17/): VersionDateDescriptionPageAuthorV0.0.012020/11/02Version 1V0.0.022020/12/07Version 2V0.0.032021/01/05Version 3V0.0.04202 - [Appendix A CPU Unit Memory](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-15/): This configuration is the factory settingCategorySpecificationNotesBITXDigital Input (DI) (Maximum 2048 points)X0~X1023 - [Appendix B System Error Detection](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-16/): ItemERR1/ERR2 LEDSR/MASKNot enough memory capacityON/ONReserveInitialization errorON/ONReserveSystem errorON/ONReserveSy - [Chapter 1 System Specifications](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-01/): FATEK M-Series PLCs are divided into four models according to their functions. Users can choose the appropriate model ac - [Chapter 10 Serial communication](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-10/): With the two built-in RS-485 communication ports and the serial expansion module of the M-series CPU Unit users can conn - [Chapter 11 Ethernet Function and Ethernet Communication](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-11/): 11-1 Setting the Network InterfaceDefault parameter of network interfaceAddressContentIP Address192.168.2.4Sub-net Mask2 - [Chapter 12 Analog input output (AIO)function](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-12/): Chapter 12 Analog input/output (AIO)function12-1 Built-in Analog Input Function12-1-1 Position and specifications of wir - [Chapter 13 PID temperature control](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-13/): 13-1 Temperature Control Instruction Description and ExamplesFUN99 PTPCTL2PID temperature control instruction 2(Build-in - [Chapter 14 Updating CPU Unit and module firmware](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-14/): 14-1 Software Updating Process14-1-1 CPU Unit NoticeApplicable to all CPU Unit models.During the updating process, do no - [Chapter 2 CPU Model Features Overview](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-02/): FATEK has been focusing on software and hardware of control system on industrial automation industry for more than 30 ye - [Chapter 3 Time setting function](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-03/): A real time clock (RTC) has been provided in the M-Series main unit, in the form of being built-in or expanded. Whether - [Chapter 4 Retentive memory allocation](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-04/): 4-1 Setting Retentive Memory In addition to providing the project data and the system information, the PLC also allows u - [Chapter 5 Interrupt Function](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-05/): 5-1 The Principle and the Structure of Interrupt FunctionThere are many jobs that M-Series PLC needs to carry out. For e - [Chapter 6 Program scanning time](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-06/): 6-1 Setting the Scanning TimeThe program scanning time means the duration required for the PLC to complete the scanning - [Chapter 7 Memory card function](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-07/): M-Series PLC supports FATEK Memory Card, and the supported features may vary among series. The memory card and descripti - [Chapter 8 High-Speed Counter and Timer](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-08/): 8-1 High-Speed CounterM series hosts are divided into two counter types: HSC and HSC[MC] according to specifications. Th - [Chapter 9 Pulse output and NC Positioning Control](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-09/): 9-1 The Methods of NC Positioning ControlPeople use ordinary motor to exercise positioning control in early stage; since - [Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-en-00/): Manual for the FATEK M-Series PLC Software Function and Application PrefaceThis Manual provides important information re ## Function/Function Block 使用手冊 - [【附錄一】 複週期指令表](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-04/): 複週期指令表Function 編號Function 名稱Function 編號Function 名稱Fun33LCNVFun176MFFlowStartFun34MLCFun177MFSysStopFun38PID2Fun178MFHome - [使用本產品注意事項](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-00/): 符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所使用的系統、機械或是裝置是否適用於FATEK產品。如未確認是否符合或適用時,本公司無須對產品的適用性負責。如客戶要求,FATEK 將提供相應的第 - [修訂紀錄](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-05/): 版本修訂日期修訂內容V1.02024/12/20初版 - [第1章 使用Function Function Block的好處](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-01/): 第1章 使用Function/Function Block的好處1-1 易於閱讀Function/Function Block(使用FCM)能夠將複雜的程式包裝成一個Function指令,使用者只需要了解Function指令輸入輸出的動作, - [第2章 FCM程式](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-02/): 本章節將介紹如何在程式單元中新增並使用FCM程式。2-1 FCM庫新增的FCM程式儲存在【專案管理】>【程式單元】>【FCM程式】。跟程式單元一樣能夠調整順序,重新命名和自定義密碼。FCM程式有別於一般程式單元,FCM程式需要設 - [第3章 Function Function Block程式](https://resource.fatek.com/index.php/2026/11/17/mplc-m09-zh-03/): 第3章 Function/Function Block程式本章節將介紹如何在UperLoigc中新增FCM程式,設定FCM參數以及屬性。3-1 開啟新專案Step 1. 選擇UperLogic左上角【菜單】 > 【開新專案】Step ## FvDesigner User Manual - [Chapter 1 FATEK FvDesigner Manual](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-01/): Introduction to FATEK FvDesignerForewordThe FATEK FvDesigner is a software tool used to design and develop FATEK HMI ser - [Chapter 10 Operation Log](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-10/): Historic logs are frequently required for the parameters and controls of certain equipment in many applications in order - [Chapter 11 Schedule](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-11/): The【Schedule】function can be used if users want the HMI to automatically execute specific actions regularly over long pe - [Chapter 12 Data Transfer](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-12/): The【Data Transfer】function can be used if the user wants the HMI to execute data transfer actions under specific conditi - [Chapter 13 Script](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-13/): Script provides a simple language to allow users to write their own programs. Available statements include logical judgm - [Chapter 14 MQTT](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-14/): MQTT is a kind of communication protocol designed for IoT with simple and slight features, it’s suitable with limited ha - [Chapter 15 Database](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-15/): It can be used to connect to the database server and upload data to the database or download data from the database to t - [Chapter 16 OPC UA](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-16/): OPC UA (OPC Unified Architecture) is a communication standard designed for industrial automation. The characteristic adv - [Chapter 17 Web Service](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-17/): REST API is a widely used interface architecture in network communication technology. It can be used to exchange data wi - [Chapter 18 Resource](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-18/): 18.1 【Image Library】The【Image Library】function can be used when designing projects with the FvDesigner to create images - [Chapter 19 Objects](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-19/): FvDesigner provides plenty of objects for users, the following is a list of all available objects and an introduction to - [Chapter 2 Window Configuration](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-02/): The default Window Configuration of FATEK FvDesigner is as shown below: Figure 10 FATEK FvDesigner Window Configuration1 - [Chapter 20 User Toolbox](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-20/): Although the【Toolbox】provided by this software is able to meet the needs of most users, the objects provided in the 【Too - [Chapter 21 Uploading, Downloading, and Simulating an HMI Project](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-21/): 21.1 【Download Current Project】When a running package (.cfrp) has been successfully built and had no errors during simul - [Chapter 22 Tool](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-22/): 22.1 【File Transfer】【File Transfer】allows the user to transfer files from the computer to the HMI or vice versa via USB - [Chapter 23 Address Registers](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-23/): The FvDesigner provides various kinds of registers. Except for the external registers of PLC, the HMI also provides some - [Chapter 24 HMI System Settings](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-24/): When the user needs to change the system settings of the HMI, such as IP, buzzer, and system time, users can enter to th - [Chapter 25 HotKeys](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-25/): When designers use FvDesigner to program HMI project, they often use some functions, such as【Compile】、【Download】and【Simu - [Chapter 26 Modbus Gateway Server](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-26/): The Modbus gateway server feature uses a HMI to serve as a gateway linked to a computer using SCADA software, HMI, or ot - [Chapter 27 PLC Integration](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-27/): 【PLC Integration】provides designers or users in pratical applications of HMI and PLC to achieve closer integration. For - [Chapter 28 User-defined Protocol](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-28/): 【User-defined Protocol】function is the consulation mainly to provide the designer to connect the device according they n - [Chapter 29 Multi-Link](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-29/): 【Multi-Link】function is to build multi-link master on FATEK HMI, other multi-link slaves on HMI can communicate with mul - [Chapter 3 System](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-03/): Click on the setting option in【System】and the related setting window will be displayed at the work space of the window.F - [Chapter 30 SearchReplace](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-30/): 30. Search/ReplaceThe【Search/Replace】function is to provide designers with more efficient and time-saving tools for plan - [Chapter 31 Use FATEK IoT on FvRT](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-31/): To make it more convenient for users to operate FvRT, IoT support has been added starting from version V1.7.15_B25391.Th - [Chapter 32 Communication Error Codes](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-32/): The following table will detailed description the HMI and PLC or other devices occurred error when communicating, each m - [Chapter 33 Elimination of HMI Abnormal Conditions](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-33/): 33.1 System Consistency Protection is EnabledIf the screen shows as below while using the HMI:Figure 579 System Integrit - [Chapter 4 Servers](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-04/): This chapter will introduce the various server functions provided by the HMI; users can use these server functions to ac - [Chapter 5 Security](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-05/): Different operating levels can be set for different objects during HMI operations so that different objects can be used - [Chapter 6 System Message](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-06/): 【System Message】is located in【Project Explorer】under the【System】tab. 【System Messages】appear in a pop-up dialogue on the - [Chapter 7 Data Log](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-07/): Objects such as【Lamp】or【Numeric Input/Display】can be used to read the real-time changes of certain register values when - [Chapter 8 Alarm](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-08/): The alarm function is used to monitor value changes in specified registers. If the value exceeds the defined range, it w - [Chapter 9 Recipe](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-en-09/): In practical applications, settings with similar properties or behaviors but have different data contents for parameters ## FvDesigner 使用手冊 - [第10章 操作記錄](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-10/): 許多應用中,常需針對某些設備的參數與控制作歷史記錄,以便在追溯使用者所關心的現象。而【操作記錄】即提供了這樣的功能需求,其可將使用者操作HMI的過程作記錄於記憶體,同時存成CSV 檔案供使用者作事後的檢視。10.1 【基本】【操作記錄】可在 - [第11章 排程](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-11/): 當HMI運行時,若希望HMI能夠長時間地自動定期執行特定動作,可使用【排程】功能。【排程】功能可依據使用者所設定的日期及時間自動執行使用者選取的動作。本章將說明排程的相關頁面與設定方式。11.1 排程列表點選FV Designer【專案管理 - [第12章 資料傳輸](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-12/): 當HMI運行時,若希望HMI能夠於特定情況執行資料搬移的動作,可使用【資料傳輸】功能,【資料傳輸】功能可依據使用者所設定的條件執行資料搬移,分成【資料到資料】以及【CSV檔案到資料】2種模式。本章將說明【資料傳輸】的相關頁面與設定方式。12 - [第13章 腳本](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-13/): 腳本是一種可讓使用者自行編寫程式的簡易語言。一個可執行的腳本通常由多道指令組成,可使用的指令包括邏輯判斷、數值運算、迴圈執行等等。使用者可以利用系統提供的指令有彈性地完成一般物件無法輕易做到的複雜工作,在不同的專案中,也可以重複利用曾經建立 - [第14章 MQTT](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-14/): MQTT是為了物聯網所設計的一種通訊協定,特點就是簡單、輕巧,適合應用於硬體資源和網路頻寬受限的環境,可達到遠端監測、資料交換等需求。訊息傳送的機制為發佈/訂閱模式,而每則訊息都必須有一個主題名稱來識別,例如溫度。客戶端為發佈者和訂閱者,發 - [第15章 資料庫](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-15/): 可用於連接資料庫伺服器,並將資料上傳至資料庫或將資料從資料庫下載至HMI,資料庫功能可在【專案管理】的功能【功能】中新增並啟用。圖 187 資料庫15.1 【資料庫伺服器】15.1.1 【一般】點選新增或編輯後會跳出【資料庫伺服器屬性】視窗 - [第16章 OPC UA](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-16/): OPC UA (OPC Unified Architecture)是為了工業自動化設計的一種通訊標準。特色優點為跨平台、通訊統一標準化,適合應用於多種機器設備的通訊環境,可達到資料交換、遠端監測等需求。圖 194 OPC UA應用架構示意圖 - [第17章 網路服務](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-17/): REST API是網路通訊技術中廣泛被使用的介面架構,可用於和第三方服務交換資料,優點為簡易方便的設計性與實用性,並遵守安全可靠有效率的通訊標準。網路應用程式可以使用REST API傳送請求(Request)到伺服器,接著伺服器便會回傳回應 - [第18章 資源](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-18/): 18.1 【圖片庫】使用FvDesigner設計專案時,可利用【圖片庫】功能預先將需要的圖片建立為【圖片庫】檔案(*.fil),方便編輯物件時使用。此外,當多人共同開發專案時,亦可匯出產生【圖片庫】檔案(*.fil),提供給其他開發者匯入使 - [第19章 物件](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-19/): FvDesigner提供許多物件以便規劃專案,以下列出所有可用物件的清單及針對各項物件進行介紹。19.1 物件規劃及修改外觀要將物件放置到工作區有以下兩種作法:在功能區的設計頁面物件區用滑鼠左鍵單擊物件後,在工作區上方再單擊滑鼠左鍵對工具箱 - [第1章 FvDesigner介紹](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-01/): 前言FvDesigner 主要是用來設計開發HMI系列產品專案的軟體工具。FvDesigner包含有簡單操作的視窗介面,與常用的Microsoft Office Ribbon介面相同,入門簡單且易於上手。豐富的圖形物件支援,可以設計出各種視 - [第20章 用戶工具箱](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-20/): 本軟體所提供的【工具箱】雖能符合使用者大部分的需求,但因【工具箱】所提供的物件皆為預設值,且無法讓使用者存取自行修改過的物件。因此本軟體提供了【用戶工具箱】功能,除了提供使用者存取自行修改過的物件外,還提供【匯入】與【匯出】功能,可快速地將 - [第21章 上下載HMI專案及模擬](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-21/): 此章節將說明如何上/下載及在電腦上模擬HMI專案。21.1 【下載目前專案】當編譯成功,經過模擬結果也無任何錯誤之後,此時就可以將打包好的工程運行包(.cfrp)下載到HMI。FvDesigner提供多樣化的下載方式,用戶可藉由序列埠,乙太 - [第22章 工具](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-22/): 22.1 【檔案傳輸】【檔案傳輸】為電腦藉由USB連接線連接到HMI,將檔案由HMI取出或傳送檔案至HMI,提供給使用者更方便的操作方式。如欲利用乙太網請利用【FTP傳輸】功能,請參考章節‎4.1 -【FTP伺服器】的說明。以下將詳細說明【 - [第23章 位址暫存器](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-23/): FvDesigner中可規畫各種不同的暫存器,除了建立PLC後可使用外部位址暫存器,HMI內也有部分可供用戶操作的空間,以下將介紹HMI內的暫存器。23.1 內部位址暫存器範圍【$U:V】揮發性記憶體暫存器系統斷電時,V記憶體不會被保存,重 - [第24章 HMI的系統設定](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-24/): 當使用者需要更改HMI的系統設定時,如IP、蜂鳴器、系統時間,可進入【系統設定】進行修改。【系統設定】功能可以直接於HMI上使用,或藉由【遠端系統設定】工具,透過網路連線遠端修改。24.1 如何進入系統設定在HMI的開機過程中,持續按壓螢幕 - [第25章 快捷鍵](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-25/): 當設計者使用FvDesigner在規劃HMI界面的專案時,常會使用到一些功能,如編譯、下載、模擬等,本軟體為了讓設計者能更方便及簡便使用,提供許多軟體操作上的快捷鍵。本章將說明FvDesigner提供的快捷鍵及組合方式。25.1 專案和檔案 - [第26章 Modbus閘道伺服器](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-26/): 【Modbus閘道伺服器】功能是指將HMI當成閘道,上位機PC使用圖控軟體、HMI或其他的Modbus設備,透過Modbus(主站) TCP 協議或者串口Modbus(主站)通訊協議連結到HMI,並透過HMI對下位的PLC、變頻器、伺服、溫 - [第27章 PLC整合功能](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-27/): 【PLC整合功能】是提供給設計者或使用者在HMI和PLC的實際應用中,達到更緊密的整合,例如可以讓使用者在實際設備運行中,透過 HMI 顯示或查看目前連線PLC( PLC)的階梯圖程式,不需要另外將PLC連結到電腦(PC),再透過 PLC的 - [第28章 自訂通訊協議](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-28/): 【自訂通訊協議】功能主要是提供設計者依照需要連線設備的協議,自行定義連線的通訊碼,而與其設備通訊,和讀取或寫入資料到其設備,一般可以使用在簡易的通訊連線,或者在軟體連結中目前尚未支援的驅動程式情況下。另外此【自訂通訊協議】功能提設計者簡易的 - [第29章 多重連線](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-29/): 【多重連線】功能是在指定的HMI上建立多重連線主站,其他有多重連線從站的HMI可經由和多重連線主站的通訊,與多重連線主站所連結之【目標連線】裝置溝通。也就是多重連線主站與連結之【目標連線】裝置溝通,多重連線從站與多重連線主站連結,並透過多重 - [第2章 視窗配置](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-02/): FvDesigner預設視窗配置如下所示:圖 10 FvDesigner視窗配置1、檔案2、專案功能區3、檔案快捷列4、軟體介面外觀選項及版本資訊5、軟體狀態列6、專案快捷工具列7、專案系統視窗8、物件及工具箱9、專案畫面視窗區2.1 檔案 - [第30章 搜尋取代](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-30/): 【搜尋取代】功能是提供給設計者在規劃專案時,更有效率並節省時間的輔助工具,例如當設計者在規劃專案時,不確定那些PLC位址或HMI內部位址是否有使用到,或者使用在哪些物件或功能上,可以透過搜尋整個專案、畫面或功能來搜尋欲搜尋位址,避免使用到相 - [第31章 在FvRT使用FATEK IoT](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-31/): 為讓用戶能更方便的使用FvRT,在V1.7.15_B25391版本開始支援使用IoT,FvRT的IoT支援iMonitor及iAccess功能。注意1:使用iAccess Insight時僅支援遠端畫面監控。注意2:如要使用此功能,需要購買 - [第32章 通訊錯誤代碼](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-32/): 表 332 通訊錯誤代碼說明錯誤代碼說明0x00000001Com Port Not Open0x00001001Dcc Illegal Parameters0x00001002Dcc Stop0x00001003Dcc Failed Se - [第33章 HMI異常狀況排除](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-33/): HMI在使用時如發生異常狀況,為避免造成無法恢復,將會進入系統保護畫面中,以下為發生時的對應方法。33.1 系統保護已啟用如果在人機使用中出現下圖的畫面,代表作業系統有毀損,容易出現於已長期使用的人機,就跟電腦長期使用後硬碟出現錯誤一樣,這 - [第3章 系統](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-03/): 可於此處查看及設定HMI系統相關的參數。圖 42 系統3.1 專案資訊3.1.1 專案檔案在專案檔案中,會顯示本專案的名稱、最後儲存時間、最後儲存的軟體版本,另可以編輯建立者及備註。圖 43 專案檔案3.1.2 機型此處可以看到HMI的詳細 - [第4章 伺服器](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-04/): 此章節會就HMI所提供的各種伺服器作介紹,透過這些伺服器,使用者可以達成遠端檔案存取、遠端畫面操控及發送郵件等等需求。4.1 【FTP伺服器】FTP伺服器可以允許使用者透過網路來存取HMI內部儲存空間,或是SD卡及USB儲存裝置上面的檔案。 - [第5章 安全](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-05/): 在操作HMI時,常需要對不同的元件設定不同的操作層級,讓不同的使用者登入HMI時可以使用及看到不同的元件,以避免操作錯誤或是確保資訊的安全性。5.1 【安全】設定5.1.1 【安全】的基本設定【安全】可在FvDesigner左方的【專案管理 - [第6章 系統訊息](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-06/): 系統訊息主要為HMI內建的文字訊息,在操作HMI時,顯示對話視窗上的文字,或者發生異常會顯示出來。6.1 【系統訊息】設定【系統訊息】可在FvDesigner左方的【專案管理】中的【系統】視窗裡點選,即可進入其設定頁面如下:圖 110 【系 - [第7章 資料蒐集](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-07/): 當HMI運行時,若需要了解某項數值的即時變化時,可以使用如【指示燈】或【數值輸入/顯示器】等物件讀取該數值。然而,若需要了解數值的長時間變化時,則需要使用【資料蒐集】功能,【資料蒐集】功能用於定時或滿足特定條件時,蒐集設定位址的數值,提供使 - [第8章 警報](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-08/): 警報功能用於監測指定暫存器的數值變化,若超過設定範圍則會記錄於表格內,亦可設定發出聲音通知或是將報告紀錄透過SMTP發送郵件。8.1 警報列表點選FvDesigner左方功能列表中的【警報】,將彈出設定頁面。圖 131 警報列表畫面表 58 - [第9章 配方](https://resource.fatek.com/index.php/2026/11/17/p5hmi-fvd-zh-09/): 在實務上的應用,設備常常利用一些有相同性質或行為,但資料內容不同的參數,作為某些製程或動作的設定,而這些參數內容的集合,即是所謂的配方。良好的配方管理將有助於提高工程或生產效率。9.1 配方的資料流在我們開始說明HMI的配方前,我們必需先了 ## Hardware Manual - [Appendix 1 FATEK Communication Protocol](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-101/): This Protocol is each communication port of FATEK PLC to communicate with the peripherals under standard mode. Any perip - [Appendix 2 PWMDA Analog Output Module](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-102/): Although FBs Series main unit has been provide analog output module, but allow for the customer who only one point analo - [Chapter 1 Introduction of FATEK FBS Series PLC](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-001/): 【Hardware】The FATEK FBSSeries PLC is a new generation of micro PLC equipped with excellent functions comparable to mediu - [Chapter 10 FBs-PLC High-Speed Counter and Timer](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-010/): 10.1FBs-PLC High-Speed Counter The counting frequency of an ordinary PLC’s software counter can only reach tens of Hz (d - [Chapter 11 The NC Positioning Control of FBs-PLC](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-011/): People use ordinary motor to exercise positioning control in early stage; since the speed and precision demand was not s - [Chapter 12 The Communication Function of FBs-PLC](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-012/): The FBs-PLC main unit has been built in the communication port0 with optional USB or RS232 interface. If additional comm - [Chapter 13 The Applications of FBs-PLC Communication Link](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-013/): As previously revealed in Chapter 12 that the FBs-PLC can support the "Ladder Program Control Interface" commu - [Chapter 14 Application of ASCII File Output Function](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-014/): The FBs-PLC's ASCII file output function allows the PLC to directly drive ASCII output devices such as printers and term - [Chapter 15 Real Time Clock (RTC)](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-015/): A real time clock (RTC) has been built in the FBs-PLC's MC/MN main unit. No matter whether the PLC is switched on or off - [Chapter 16 7/16-Segment LED Display Module](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-016/): 16.1 FBs-7SG Overview There two models in the FBs-7SG range: 7SG1 and 7SG2. Each of which has one or two 8-digit display - [Chapter 17 Thumbwheel Switch Input Module](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-017/): FBs-32DGI is a multiplex input module. One 32DGI module can support up to 32 digits thumbwheel switch or 128 discrete sw - [Chapter 18 AIO Module](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-018/): 18.1FBs-6AD Analog Input Module FBs-6AD is one of the analog input modules of FATEK FBs series PLC. It provides 6 channe - [Chapter 19 Analog Input/Output Expansion Board](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-019/): Since the main units, which have less than 14 points, of FBs Series does not provide right expansion module input/output - [Chapter 2 System Configuration](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-002/): 2.1 Single-Unit System of FBS-PLC Intelligent Peripherals BASEDigital I/O Expansion Unit/Module TCHMI FBS-24XY Load Cell - [Chapter 20 Temperature Measurement of FBs-PLC and PID Control](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-020/): FBs-PLC provides two kinds of temperature modules to meet the great temperature measurement applications. One kind of th - [Chapter 21 Analog Input and Temperature Measurement Combination](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-021/): Module In response to actual needs of user applications, FBs-PLC provides an economical combination of temperature and a - [Chapter 22 General Purpose PID Control](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-022/): 22.1Introduction of PID Control As the general application of process control, the open loop methodology may be good eno - [Chapter 3 Expansion of FBS-PLC](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-003/): If the I/O point of the. Main unit of the applied FBS-PLC is not enough for a specific application, then can expand it w - [Chapter 4 Installation Guide](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-004/): •Danger1. Turn off all power during installation of FBS-PLC or related equipments to prevent electric shock or damage to - [Chapter 5 Power Supply Wiring, Power Consumption Calculation, and Power Sequence Requirements](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-005/): Calculation, and Power Sequence Requirements FBS-PLC internally has three kinds of circuit: a 5VDC logic circuit, a 24VD - [Chapter 6 Digital Input (DI) Circuit](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-006/): The FBS-PLC provides the ultra high speed differential double end 5VDC inputs (i.e., single input with two terminals wit - [Chapter 7 Digital Output (DO) Circuit](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-007/): The digital outputs of FBS-PLC are available in the following two structures: the 5VDC ultra high speed Line-driver type - [Chapter 8 Test Run, Monitoring and Maintenance](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-008/): •WarningDuring maintenance, be sure to turn off the input power of PLC in case the actions to touch any terminal on PLC, - [Chapter 9 FBs-PLC Interrupt Function](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-en-009/): 9.1The Principle and the Structure of Interrupt Function There are many jobs that FBs-PLC needs to carry out. For exampl ## Instruction Manual - [Appendix 1 FB-DAP Simple Human Machine Interface](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-103/): In addition to timer, counter, register, and contact data access function, the date setter of FB-DAP can connect to many - [Appendix 1 FBs-PACK Operation Instruction](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-101/): Appendix I FBs-PACK Operation Instruction The main unit of FBs series PLC provides the function to write ladder program - [Appendix 2 FBs BDAP User’s Manual](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-104/): The function of the data access board (FBs-BDAP) is mainly used for displaying and setting of the calendar time and disc - [Appendix 2 FBs BDAP User’s Manual (V1.0)](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-105/): The function of the data access board (FBs-BDAP) is mainly used for displaying and setting of the calendar time and disc - [Chapter 1 PLC Ladder Diagram and the Coding Rules of Mnemonic](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-001/): 【Instruction】In this chapter, we would like to introduce you the basic principles of ladder diagram, in addition, the co - [Chapter 2 FBs-PLC Memory Allocation](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-002/): 2.1 FBS-PLC MemoryAllocationRemark: DISCRETEX(256)X255SRAMX0Save statusFBS-PACKX0 1. When the Read Only Register (ROR) X - [Chapter 3 FBs-PLC Instruction Lists](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-003/): 3.1 Sequential Instructions Instruction Operand Symbol Function Descriptions Execution Instruction typeTime ORG X,Y,M, S - [Chapter 4 Sequential Instructions](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-004/): Chapter 4 Sequential Instructions The sequential instructions of FBs-PLC shown in this chapter are also listed in sectio - [Chapter 5 Description of Function Instructions](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-005/): 5.1The Format of Function InstructionsIn this chapter we will introduce the function instructions of FBs-PLC in details. - [Chapter 6 Basic Function Instruction](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-006/): Basic Function Instruction T TIMER T Symbol Operand Tn: Timer Number TB: Time Base (0.01S, 0.1S, 1S) HRPV: Preset value - [Chapter 7 Advanced Function Instructions](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-007/): Flow Control Instruction I FUN22 P BREAK FROM FOR AND NEXT LOOP FUN22 P BREAK (BREAK) BREAK ● When execution control〝EN〞 - [Chapter 8 Step Instruction Description](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-en-008/): Structured programming design is a major trend in software design. The benefits are high readability, easy maintenance, ## Instruction User Manual - [Chapter 1. PLC Ladder Diagram and the Coding Rules of Mnemonic](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-01/): In this chapter, we would like to introduce you the basic principles of ladder diagram.1-1 The Operation Principle of La - [Chapter 2. Configuration of memory, single point (Digital) and Registe](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-02/): Chapter 2. Configuration of memory, single point (Digital) and Register in PLC※※Being designed with very broad flexibili - [Chapter 3. M PLC Instruction Lists](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-03/): 3-1 Sequential InstructionsOperandSymbolFunctionInstruction TypeX,Y,M,S,T,CStarting a network with a normally open (A) c - [Chapter 4. Sequential Instruction](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-04/): This chapter only describes the Element features and functions of sequence commands.4-1 Element Description4-1-1 Charact - [Chapter 5. Description of Function Instructions](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-05/): 5-1 The Format of Function InstructionsFunction Instructions of M PLC will be divided into four parts including input co - [Chapter 6. Basic Function Instruction](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-06/): 6-1 TIMER(T)TTIMERTSymbolTB: Time Base (0.001S,0.01S, 0.1S, 1S)OperandTn: Timer NumberPV: Preset value of the timer.Rang - [Chapter 7. Advanced Function Instructions](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-07/): 7-1 Arithmetical Operation Instructions(FUN24~33)7-1-1 Summation of Block Data(SUM)FUN24 D PSUMSUM (Summation of block d - [Chapter 8. Step Instruction Description](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-08/): Structured programming design is a major trend in software design. The benefits are high readability, easy maintenance, - [Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-en-00/): Precautions on Using the ProductCompliance with the application-related conditionsThe user shall evaluate the suitabilit ## Motion User Manual - [Chapter 1 Motion Parameters and Status](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-01/): Summary of M-PLC Motion Control UnitThis section describes the function and overview of the M-PLC Motion Control Unit. I - [Chapter 10 Home Return](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-10/): HOME ReturnWhen using Relative Encoder as the displacement detector, normally the user needs to execute the return actio - [Chapter 11 JOG Mode](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-11/): JOG ModeThis product provides Fun180 for the user to quickly complete the JOG function for the Servo. The relevant descr - [Chapter 12 Realtime Data Chart](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-12/): Realtime Data ChartClick [Motion] → [Motion Network] → “Right mouse button” → [Realtime Data Chart] in project managemen - [Chapter 13 Test Run](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-13/): Test RunThe Test Run is the motion control function specially designed for UperLogic and it belongs to built-in features - [Chapter 14 Hand Wheel Mode](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-14/): Hand Wheel Mode\The hand wheel is mainly used to control the pulse number of the input axis. When using the hand wheel f - [Chapter 15 Speed Control and Torque Control](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-15/): Speed Control and Torque ControlThis section describes the speed control and the torque control required for the M-PLC. - [Chapter 16 Synchronous Control, Flying Shear](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-16/): Synchronous Control, Flying Shear(Synchronization Function Parameter Table/Electronic Cam Setting)This section describes - [Chapter 17 Motion Alarm List](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-17/): Motion Alarm ListThe alarms included in the FATEK M-PLC Alarm List are mainly divided into the following three types: Mo - [Chapter 18 Motion Probe](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-18/): Motion ProbeThe probe function is used to precisely capture the position of an axis or detect specific events during mot - [Chapter 19 Motion Example Application](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-19/): Motion Example Application19-1 Interrupt Constant FeedBackgroundThe grinding machine is a common grinding tool, which us - [Chapter 2 Motion Parameters and Status](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-02/): Motion Parameters and Status(Special Register and Relay)This section will introduce the layout of memory in the M-PLC an - [Chapter 3 EtherCAT function and configuration](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-03/): EtherCAT Function and ConfigurationThis section describes the EtherCAT related function and configuration. EtherCAT is a - [Chapter 4 Axis Parameters and Setting](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-04/): Axis Parameters and SettingThis section describes the parameter setting and the axis connection setting related informat - [Chapter 5 Point Table and Point Parameter](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-05/): Point Table and Point ParameterThis section describes the setting method and the parameters required for the motion poin - [Chapter 6 Ladder Motion Commands](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-06/): Ladder Motion CommandsTo execute Motion Control, the M-PLC Controller realizes the user motion sequence control by using - [Chapter 7 Introduction of Motion Flow](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-07/): Introduction of Motion FlowThis section describes the motion control method specially designed for FATEK M-PLC and it is - [Chapter 8 Position Control and Interpolatio](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-08/): Position Control and InterpolationThis section describes the positioning control and the interpolation functions. When u - [Chapter 9 Motion Parameter Mapping Table](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-09/): Motion Parameter Mapping Table9-1 Introduction of Motion Parameter Mapping TableThe motion parameter mapping table allow - [Precautions on Using the Product](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-en-00/): Compliance with the application-related conditionsThe user shall evaluate the suitability of FATEK product and shall ins ## Pages - [FATEK Technical Manuals](https://resource.fatek.com/index.php/manuals-en/): FATEK product manuals, organized by product and manual. Select a chapter to read it. - [FATEK 技術手冊目錄](https://resource.fatek.com/index.php/manuals-zh/): FATEK 產品技術手冊,依產品與手冊分類,點選章節即可閱讀。 - [範例頁面](https://resource.fatek.com/index.php/sample-page/): 這是一個範例頁面。頁面與網站文章不同,因為它顯示的位置為固定位置,並且大多數的佈景主題會將它顯示在網站導覽選單中。大多數人會新增一個〈關於〉頁面,以便向網站訪客介紹自己。〈關於〉頁面的內容類似以下示範: 嗨,你好!白天我是一位郵差,晚上則是 ## SC3 Servo Driver User Manual - [Chapter 1 Basic Information on SC3](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-01/): Basic Information on SC3 1.1 SC3 Series AC Servo driver The SC3 series AC servo drivers are designed for applications th - [Chapter 10 Parameter Lists](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-10/): 10.1 List of Parameters 10.1.1 Interpreting the Parameter Lists 10.1.2 List of Parameters The following table lists the - [Chapter 11 Tuning Software(ProTuner)](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-11/): Chapter11.Tuning Software(ProTuner) Using the host computer software (ProTuner), the following functions can be realized - [Chapter 12 Tuning](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-12/): 12.1 Overview and Flow of Tuning Tuning is performed to optimize response by adjusting the servo gains in the servo driv - [Chapter 13 Regenerative Resistor](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-13/): 13.1 The selection and calculation method for regenerative resistors. When the direction of the motor's torque and speed - [Chapter 14 Return to Homing Mode Instructions](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-14/): 14.1 Overview of Homing Mode Functionality. The Homing Mode is used during machine startup or reset to accurately positi - [Chapter 2 Selecting a SC3 Servo Driver](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-02/): 2.1 Ratings and Specifications 2.1.1 Ratings ■ 1-phase 220VAC / 3-phase 220VAC ◆ SC303AAD▯▯ / SC306AAF▯▯ / SC308AAG▯▯ / - [Chapter 3 Installation of Servo driver](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-03/): 3.1 Installation Precautions Refer to the following section for the ambient installation conditions. ■ Installation Near - [Chapter 4 Wiring and Connecting Servo driver](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-04/): 4.1 Precautions related to wiring 4.1.1 General Precautions DANGER ● Do not change any wiring while power is being suppl - [Chapter 5 Basic Functions That Require Setting before Operation](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-05/): 5.1 Manipulating Parameters(Pn▯▯▯) This section describes the classifications, notation, and setting methods for the par - [Chapter 6 Application Functions](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-06/): 6.1 I/O Signal Allocations Functions are allocated to the pins on the I/O signal connector (CN1) in advance. You can cha - [Chapter 7 Trial Operation and Actual Operation](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-07/): This chapter provides information on the flow and procedures for trial operation and convenient functions to use during - [Chapter 8 Panel Displays and Panel Operator Procedures](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-08/): 8.1 Panel Operator 8.1.1 Panel Operator Key Names and Functions The Panel Operator consists of a panel display and Panel - [Chapter 9 Maintenance](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-en-09/): 9.1 Inspections and Part Replacement This section describes inspections and part replacement for SERVO DRIVER. 9.1.1 Ins ## SC3 伺服驅動器使用手冊 - [第10章 參數一覽](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-10/): 10.1 伺服參數一覽 10.1.1 一覽表的判別方法 10.1.2 伺服參數一覽表 參數一覽表如下所示。 (註)以下參數為出廠設定,請勿變更。 • 系統保留參數 • 本手冊未記載的參數 Pn 編號大小名稱 設定範圍 設定單位出廠設定 有效 - [第11章 調試軟體(ProTuner)的操作](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-11/): 第11章 調試軟體(ProTuner)的操作 使用上位機軟體(ProTuner)可以線上實現以下功能: • 參數管理:參數的設定和調整 • 狀態監測:監測伺服系統的工作狀態和相關資料 • 採用跟蹤:對伺服的電源、指令、輸出電流等相關資料採用 - [第12章 調整](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-12/): 12.1 調整的概要和流程 調整是指,通過調整伺服單元的伺服增益,優化響應性的功能。 伺服增益通過多個參數 (速度環增益、位置環增益、濾波器、摩擦補償、轉動慣量比等)的組合進行設定,它們之間會相互影響,因此設定時必須考慮到各個參數設定值之間 - [第13章 外接回生電阻說明](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-13/): 13.1 回生電阻的選擇與計算方法 當馬達的出力矩和轉速的方向相反時,會從負載端產生電能傳回至驅動器內,此時需要回生電阻來消耗掉回升電能,避免驅動器故障,使用者可透過下方公式計算出是否需要外接回生電阻。 1. 請先依下表查出伺服馬達的慣量與 - [第14章 回原點模式說明](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-14/): 14.1 回原點模式功能概述 回原點模式用於設備啟動或復位時,將運動軸定位至精準的原點位置,確保後續加工或運作的基準正確。此模式結合感測器訊號與編碼器Z 相訊號,達成安全且高精度的定位。 14.2 回原點相關參數與訊號開關說明 1. 尋找原 - [第1章 伺服驅動的基本資訊](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-01/): 1.1 SC3 系列交流伺服驅動器 SC3 系列伺服驅動主要用於需要“高速、高頻、高定位精度”的場合,該伺服驅動可以在最短的時間內最大快地發揮機器性能,有助於提高生產效率。 1.2 銘牌的判別方法 驅動器銘牌標注的基本資訊如下圖所示。 1. - [第2章 伺服驅動的選型](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-02/): 2.1 額定值和規格 2.1.1 額定值 ■ 單相220VAC/三相220VAC ◆ SC303AAD▯▯ / SC306AAF▯▯ / SC308AAG▯▯ / SC310AAH▯▯型號 03A 06A 08A 10A 額定輸出電流 [A - [第3章 伺服驅動器的安裝](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-03/): 3.1 設置注意事項 關於設置的環境條件,請參照以下內容。 2.1.2 規格表■ 安裝在發熱體附近時 為使伺服驅動器周圍的溫度符合環境條件,請控制因發熱體的熱輻射或對流而造成的升溫。 ■ 安裝在振動源附近時 請在伺服驅動器的安裝面上安裝防振 - [第4章 伺服系統的接線](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-04/): 4.1 接線的相關注意事項 4.1.1 一般注意事項 危險 ● 通電過程中請勿變更接線,否則會導致觸電或受傷。 警告 ● 請由專業技術人員進行接線或檢查作業,否則會導致觸電或產品故障。 ● 請慎重確認接線,電源輸出迴路可能會因接線錯誤,發生 - [第5章 運行前需設定的基本功能](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-05/): 5.1 參數(Pn▯▯▯)的操作 下面介紹本手冊中使用的參數的分類、書寫方法、設定方法 5.1.1 參數的分類 伺服驅動的參數分為以下 2 類。 類別 含義 設定用參數 運行所需基本設定參數 調整用參數 調整伺服性能的參數 使用面板操作器做 - [第6章 應用功能](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-06/): 6.1 輸入輸出訊號的分配 輸入輸出訊號連接器(CN1)上有預先分配的功能,但部分端子可分配其它功能或變更極性。功能的分配及極性的設定通過參數執行。 以下對輸入輸出訊號的分配進行說明。 6.1.1 輸入訊號的分配 變更輸入訊號的分配後使用時 - [第7章 試運行、運行](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-07/): 介紹試運行的流程和操作步驟以及試運行時使用方便的功能。 7.1 試運行的流程 7.1.1 伺服馬達試運行的流程 試運行的步驟如下所述。 步驟內容 1 設置、安裝 根據設置條件設置伺服馬達和伺服驅動。首先,進行空載時的動作確認。此處未將伺服馬 - [第8章 面板顯示和面板操作器的使用](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-08/): 8.1 面板操作器 8.1.1 面板操作器按鍵的名稱和功能 面板操作器由面板顯示部和面板操作器按鍵構成。 通過面板操作器可以顯示狀態、執行協助工具、設定參數並監視伺服驅動的動作。 面板操作器按鍵的名稱及功能如下所示。 按鍵 名稱 功能 功能 - [第9章 維護](https://resource.fatek.com/index.php/2026/11/17/sc3-sc3man-zh-09/): 9.1 檢查和部件更換 下面對伺服驅動的檢查和部件更換進行說明。 9.1.1 檢查 伺服驅動不需要日常檢查,但對下列事項一年至少需要檢查一次以上。 檢修項目 檢查間隔時間檢修要領 故障情況時的處理 外觀檢修 至少每年一次 不得有垃圾、灰塵、 ## Software User Manual - [Chapter 1 Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-01/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 10 Module configuration](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-10/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 11 Communication Function](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-11/): This section describes the operating procedure required for executing the PLC online and offline as well as the PLC prog - [Chapter 12 Monitoring Function](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-12/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 13 Security](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-13/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 14 Tools](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-14/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 2 Installation instructions](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-02/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 3 Introduction of UperLogic](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-03/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 4 Project Management](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-04/): This section describes how to open and save the project as well as certain relevant setting in order that the user may q - [Chapter 5 System Parameters](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-05/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 6 Creating Program](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-06/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 7 Creating Tables](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-07/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 8 Comment and Label Information](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-08/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Chapter 9 Motion control](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-09/): ⚠DangerWhen installing or removing the M-series CPU modules and various expansion modules or the equipment connected to - [Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-en-00/): Manual for the FATEK M-Series PLC Software PrefaceThis Manual provides important information related to the use of the F ## Structured Language (ST) Manual - [Chapter 1 Understand Structured Language ST](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-01/): 1-1 Features of ST LanguageIn the early days of automation control, when editing the logic of the programmable logic con - [Chapter 2 User Interface of Uperlogic ST](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-02/): 1-1 Interface OverviewFor all ST programs in the current project, double-click the name with the left mouse button, and - [Chapter 3 Basic Program Structure of Uperlogic ST](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-03/): 1-10 IntroductionThis chapter will explain the methods of applying basic ST Language programming.3-1-1 Character Encodin - [Chapter 4 ST Editing Environment Support Function List](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-04/): 1-16 Name comparison between Ladder and ST editing environment instructionsST function nameParameterInstruction manual c - [Preface](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-00/): PrefaceBefore using the product, be sure to read this Manual carefully in order to get familiar with and understand its - [Revision History](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-en-05/): VersionRevision dateRevision contentV1.02024/12/30first editionV1.12026/02/25Corrected the incorrect image on page 35. ## 二進位通訊協定使用手冊 - [主僕定位與通訊互動關係](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-01/): 主僕定位與通訊互動關係本通訊協定是建立在任何設備只要可以符合其通訊訊息格式,並使用相同的通訊參數溝通,任何設備皆可與M系列PLC通訊,M系列PLC會作為僕系統與主系統通訊。通訊時將為主系統向M系列PLC傳送命令,如果符合訊息格式PLC將會回 - [命令碼](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-06/): 命令碼命令碼40 PLC狀態讀取如果 PLC 配備記憶卡且設定了 ID,且正常情況下 PLC 狀態為“RUN”條件下,MASTER 讀取的 PLC 系統狀態如下:(B5、B3、B0均為1,其他均為0即STATUS為29發送命令如下:命令訊息 - [命令碼總覽](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-05/): 命令碼總覽數值(16進制)敘述命令長度控制資料長度0x40PLC狀態查詢1-0x41PLC RUN/STOP控制1-0x42單一個單點運作控制110x43多個連續單點之抑能/致能狀態讀取11~2560x44多個連續單點狀態讀取11~2560 - [永宏PLC通訊訊息格式](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-02/): 永宏PLC通訊訊息格式其中使用時主站發送的命令訊息格式如下:命令訊息段落開頭字元有效封包編號訊息長度訊息內容偵誤值(Checksum)結尾字元訊息內容0x510x10,固定給Binary 通訊協定使用的N(基於訊息長度而有所不同)M(基於所 - [錯誤碼](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-04/): 錯誤碼數值(16進制)敘述0x00無錯誤發生。0x02非法數值。0x04非法格式,或通訊格式無法執行。0x05無法RUN PLC,PLC Run時階梯圖Check sum錯誤。0x06無法RUN PLC,PLC Run時階梯ID與PLC I - [類型碼](https://resource.fatek.com/index.php/2026/11/17/mplc-m08-zh-03/): 類型碼回覆訊息段落類型碼(單點)長度(Byte)單點0x58 : X10x59 : Y10x4D : M10x53 : S10x54 : T10x43 : C116 bit暫存器0x57+0x58 : WX20x57+0x59 : WY20 ## 功能與應用使用手冊 - [修訂紀錄](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-17/): 版本修訂日期修訂內容頁數修改者V1.0.02025/01/23正式版allV1.0.12025/04/09移除FUN149錯誤資訊SR、WR(P.9-73)修正7-1 SD卡操作敘述(P.7-3)修正第8章目錄編號錯誤移除附錄錯誤燈號(至硬 - [前言](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-00/): 前言本手冊用於說明使用FATEK M系列PLC CPU 模組時之必要資訊,請在使用本產品前閱讀並確實瞭解本手冊之內容後再行使用。如若有任何疑問或意見,請洽詢FATEK代理經銷商保固內容和責任限制。保固內容FATEK的產品保固期是指產品自售出 - [第10章 串列通訊](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-10/): 藉由M系列主機內建之兩個RS-485通訊埠以及串列擴充模組,使用者可與具有相同串列硬體通訊介面之智慧型週邊透過通訊方式作連線整合應用。FUN151(CLINK)通訊連線便利指令可指定那個通訊埠以何種工作模式運作,共有Mode 0、1、2、3 - [第11章 乙太網路功能與乙太網路通訊](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-11/): MPLC主機內建乙太網路埠,提供多元的網路功能:支援常見主僕式網路通訊如Modbus TCP,滿足一般應用的系統需求集成永宏自有網絡協議,在使用便利性及通訊效率上完美整合永宏自有產品搭載永宏自有雲,實現遠端維護以及遠端監控的應用支援MQTT - [第12章 類比輸入 出(AIO)功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-12/): 第12章 類比輸入/出(AIO)功能12-1 內建類比輸入功能12-1-1 配線位置與規格通用與進階運動型主機共具備兩個類比輸入通道,支援0~10V電壓輸入與0~20mA電流輸入,解析度為12 位元,需搭配2x3歐規端子接頭一起使用。圖 9 - [第13章 溫度PID控制](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-13/): 13-1 溫控便利指令說明與範例(FUN 99)FUN99 PTPCTL2PID溫控便利指令2 (內建PID auto-tunning) ( PID TEMPERATURE CONTROL INSTRUCTION-Build-in PID - [第14章 主機及模組韌體更新](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-14/): 14-1 軟體更新流程14-1-1 主機注意事項適用於所有主機機型。請勿在更新時斷電或拔除當前通訊連接線,以免造成更新失敗。若更新時出現失敗,請重新執行步驟。若出現非預期的更新失敗造成主機無法成功開機,請參考14-2-1一節。步驟 (1) - [第1章 系統規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-01/): FATEK M系列PLC依功能分為四種型號。使用者可依設備工程的需要選擇合適的型號。各型號之間的差異請參考CPU硬體手冊。 - [第2章 主機功能概述](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-02/): 永宏電機專注於工業自動化控制器的軟、硬體研發超過三十年,包括PLC可程式控制器、HMI人機介面、Servo 伺服驅動器以及SCADA軟體等,為各種工具機設備提供最佳的自動化解決方案。M系列PLC是基於永宏累積整個世代的自動化經驗,全新設計打 - [第3章 時間功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-03/): 內建的萬年曆時鐘(Real Time Clock),讓主機無論在供電或斷電情況下,RTC 均可正確計時。其所提供之時間資訊有週、年、月、日、時、分、秒等時間值資料,使用者可利用此時間功能來做終年無休之24小時控制(例如商家或工廠每日定時之開 - [第4章 斷電保持功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-04/): 4-1 斷電保存設定除了專案資料與系統資訊外,使用者也能夠對重要資料暫存器及數位輸出點位進行斷電保存,透過相關記憶體規劃即可成功配置保持對象;同時主機也提供類比輸出暫存器(OR)的保持設定,彈性的設定在不同的專案應用中可以輕鬆達成需求並節省 - [第5章 中斷功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-05/): 5-1 中斷之原理與架構PLC所需執行之工作繁複眾多,有高達幾十k Words的使用者程式要解析,1024點I/O狀態要抓取或更新,有數個通訊埠需服務。一般來說,PLC會依序地將上述所有工作由第一項工作開始逐一地執行到最後一項工作為止,再循 - [第6章 程式掃描時間](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-06/): 6-1 掃描時間設定程式掃描時間為PLC掃描一次程式變化所需要的時間,PLC會按照程序從左到右,從上到下,不斷循環掃描的工作方式。該工作方式是在系統程序的控制下順序掃描各輸入點的狀態,按用戶程序進行運算處理,然後依照順序向各輸出點發出相應的 - [第7章 記憶卡功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-07/): M PLC 支援永宏專用記憶卡,提供的支援規格會依照選購的主機機型不同而異。記憶卡的型號與功能說明如下:型號MFM06檔案系統FAT32功能主機/擴充模組韌體更新系統備份還原(暫存器/專案/系統資訊)記憶卡暫存器存取複製保護資料收集主機/擴 - [第8章 高速計數器與高速計時器](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-08/): 8-1 高速計數器一般PLC之軟體計數器之計數頻率僅能達數十Hz(視掃描時間而定),若超過將產生漏數甚至完全無法計數,此時必須使用高速計數器(High-Speed Counter簡稱HSC)才能勝任。M系列主機依規格分為HSC及HSC[MC - [第9章 脈波輸出與NC定位控制](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-09/): 9-1 NC定位控制之方式早期使用一般馬達來作定位控制,由於速度不快、或者精度要求不高,所以足以應付所需;當機械運轉為了求取效率而將速度加快時,當製成品品質、精度要求愈高時,馬達停止位置之控制就不是一般馬達所能勝任了!解決此問題之最佳方案是 - [附錄A 主機記憶體](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-15/): 本配置為出廠時之設定項 目規 格備 註單點︽BIT狀態︾X輸入接點(DI) (最大點數2048點)X0~X1023 (1024)對應至外界數位輸入Y輸出繼電器(DO) (最大點數2048點)Y0~Y1023 (1024)對應至外界數位輸出T - [附錄B 系統錯誤偵測](https://resource.fatek.com/index.php/2026/11/17/mplc-m03-zh-16/): 項目ERR1/ERR2 LEDSR/MASK記憶體不足ON/ON保留初始化錯誤ON/ON保留系統錯誤ON/ON保留系統堆棧錯誤ON/ONR35361/0x0200系統校驗碼錯誤指示ON/ONR35361/0x0004上電檢測為試運行斷電ON ## 指令使用手冊 - [使用本產品注意事項](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-00/): 使用本產品注意事項符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所使用的系統、機械或是裝置是否適用於FATEK產品。如未確認是否符合或適用時,本公司無須對產品的適用性負責。如客戶要求,FATE - [修訂紀錄](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-09/): 版本修訂日期修訂內容頁數修改者V0.0.0120201102第一版V0.0.0220201207第二版V0.0.0220210105第三版V1.020210426第四版502V1.0120250507移除LBL、CALL、FLBL中錯誤的中 - [第1章 PLC階梯圖程式基本原理](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-01/): 本章將介紹 PLC 階梯圖程式之基本原理。1-1 階梯圖工作原理階梯圖為二次世界大戰期間所發展出來之自動控制圖形語言,是歷史最久、使用最廣之自動控制語言,最初只有 A (常開)接點、B (常閉)接點、輸出線圈、計時器、計數器等。基本機構元件 - [第2章 PLC內部之記憶體配置及其單點(數位)與暫存器明細](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-02/): 第2章 PLC內部之記憶體配置及其單點(數位)與暫存器明細※※M Serial PLC在設計上,一般暫存器區R(34768個words)可以用間接定址存取,彈性很大,但也很容易因為間接定址參數值使用不當而造成誤寫資料的問題.至於唯讀暫存器區 - [第3章 M SERIES 指令一覽表](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-03/): 3-1 順序指令一覽表運算元符號功能指令類別X,Y,M,S,T,C網路以A接點開始網路起始指 令網路以B接點開始網路以上微分接點開始網路以下微分接點開始網路以開路接點開始網路以短路接點開始X,Y,M,S,T,C母線或分歧線以A接點開始母線或 - [第4章 順序指令說明](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-04/): 第4章 順序指令說明本章僅就順序指令之元件特性及功能作說明。4-1 元件指令特性說明4-0-1 A、B、TU、TD接點元件特性輸入模組上X0輸入點之動作A接點元件之狀態B接點元件之狀態TU接點元件之狀態 TD接點元件之狀態A、B、TU、TD - [第5章 應用指令說明](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-05/): 第5章 應用指令說明5-1 應用指令之通則M系列PLC之應用指令可分為輸入控制、指令號碼名稱、運算元及功能輸出四部分。而各指令之輸入控制、運算元、及功能輸出之數目不盡相同(請參閱各指令說明)。階 梯 圖例1:單輸入指令例2:多輸入指令應用指 - [第6章 基本應用指令](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-06/): 第6章 基本應用指令6-1 一般計時器(T) T一般計時器(TIMER)T指令說明TB:時基(Time Base),有0.001S、0.01S、0.1S,1S四種。運算元Tn:計時器號碼,為儲存累計之計時時間(即現在值CV)。PV:(Pre - [第7章 進階應用指令](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-07/): 第7章 進階應用指令7-1 數學運算指令(FUN24~33)7-0-1 總和計算(SUM) FUN24 D PSUM總和計算(SUM)FUN24 D PSUM指令說明S:來源暫存器之起頭號碼N:欲總和之暫存器個數(由S開始連續N個)D:存放 - [第8章 步進指令說明](https://resource.fatek.com/index.php/2026/11/17/mplc-m07-zh-08/): 第8章 步進指令說明結構化程式設計是軟體設計的一大趨勢,它的特點是可讀性高、維護、更新容易,軟體品質可靠性大大提昇。尤其當控制偏向機械流程控制時,使用傳統的設計方式來設計程式,往往令第三者難以接手,也就是程式可讀性低、更新、維護風險較高。因 ## 指令篇 - [第1章 PLC 階梯圖程式基本原理及簡碼指令之轉譯法則](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-001/): 【指令篇】本章將介紹PLC階梯圖程式之基本原理,以及將階梯圖程式轉換成簡碼指令(Mnemonic)之轉譯法則。1.1階梯圖工作原理階梯圖為二次世界大戰期間所發展出來之自動控制圖形語言,是歷史最久、使用最廣之自動控制語言,最初只有A(常開)接 - [第2章 FBS-PLC 內部之記憶體配置及其單點(數位)與暫存器明細](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-002/): 2.1 FBS-PLC記憶體配置圖註* 1.當記憶體配置規劃有唯讀暫存單X(256)X255SRAMX0Save statusFBS-PACKX0器(ROR)時,PLC在每次RUN之前會自動將ROR專區內之Y0X255Y0 ROR值載入(覆 - [第3章 FBs-PLC 指令一覽表](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-003/): 3.1 順序指令一覽表指令碼運算元符號功能執行速度指令類別ORG 網路以A接點開始0.33uS ORG NOT X,Y,M, 網路以B接點開始0.54uS 網路起始ORG TU S,T,C 網路以上微分接點開始ORG TD 網路以下微分接點 - [第4章 順序指令說明](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-004/): 第4章:順序指令說明 FBs-PLC之順序指令如第3.1節〝順序指令一覽表〞所列,其用法規則請參閱第1章〝PLC階梯圖程式基本原理及簡碼指令之轉譯法則〞所述,本章僅就順序指令之運算元種類範圍、元件特性及功能作說明。4.1 順序指令之運算元種 - [第5章 應用指令說明](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-005/): 5.1 應用指令之通則FBs系列PLC之應用指令可分為輸入控制、指令號碼名稱、運算元及功能輸出四部分。而各指令之輸入控制、運算元、及功能輸出之數目不盡相同(請參閱各指令說明)。在FP-08程式書寫器上除常用之T、C、SET、RST四指令及S - [第6章 基本應用指令](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-006/): 基本應用指令T 一般計時器(TIMER)T 指令說明階梯圖符號運算元ENTBTUP(FO0)Tn:計時器號碼,為儲存累計之計時TnPV控制計時時間(即現在值CV)。PV:(Preset Value)為計時器之設定 值。TB:時基(Time - [第7章 進階篇應用指令](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-007/): 流程控制指令一FUN22 PFOR與NEXT迴圈之跳出指令FUN22 PBREAK (BREAK) BREAK ● 當執行控制〝EN〞=1或由0→1(P指令)時,將跳出該FOR與NEXT構成之迴 圈程式。● 在FOR與NEXT指令所構成之迴 - [第8章 步進指令說明](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-008/): 結構化程式設計是軟體設計的一大趨勢,它的特點是可讀性高、維護、更新容易,軟體品質可靠性大大提昇。尤其當控制偏向機械流程控制時,使用傳統的設計方式來設計程式,往往令第三者難以接手,也就是程式可讀性低、更新、維護風險較高。因此,專門針對機械動作 - [附錄一 FBs-PACK 操作說明](https://resource.fatek.com/index.php/2026/11/17/fbs-ins-zh-101/): 為了機台生產與維護方便,FBs系列主機備有程式記憶匣(FBs-PACK)可供客戶選購使用。將Ladder程式與資料暫存器燒錄至FBs-PACK(MEMORY_PACK)的最大好處是程式與資料能夠長久的保存及便利的維護。 FBs-PACK(M ## 擴充模組規格手冊 - [使用本產品注意事項](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-00/): 符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所使用的系統、機械或是裝置是否適用於FATEK產品。如未確認是否符合或適用時,本公司無須對產品的適用性負責。如客戶要求,FATEK 將提供相應的第 - [修訂紀錄](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-21/): 版本修訂日期修訂內容V1.02024/12/20初版V1.12024/12/20Plug-in 擴充版應用設定和擴充模組應用設定 - [第10章 本地I O擴充模組規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-10/): 第10章 本地I/O擴充模組規格10-1 數位輸入模組規格 M系列PLC之數位輸入模組係指當M系列CPU模組所提供之數位輸入資源不敷使用時,可藉由擴充模組之附加,來擴充其數位輸入數目。10-1-1 M16X規格各部位名稱和功能M16X各部位 - [第11章 周邊與附件](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-11/): 11-1 M PLC專用記憶卡11-1-1 MFM06規格各部位名稱和功能MFM06技術規格MFM06技術規格表項目技術規格型號MFM06記憶卡容量8G (2G系統+ 6GB Data-log)功能OS更新系統備份 (暫存器資料/專案)專案 - [第12章 Plug-in 擴充板應用設定](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-12/): 12-1 數位輸入板12-1-1 MB-4X此為MQ機型的數位輸入Plug-in擴充板,最多擴充兩個,上方的固定為X16-X19,下方的固定為X20-X23,其規格與使用方法如同M16X模組,詳細請參考M16X。12-2 數位輸出板12-2 - [第13章 擴充模組應用設定](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-13/) - [第14章 擴充模組暫存器設定](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-14/): 14-1 控制字控制讀取和寫入配置設定的位址,同時顯示動作狀態。類型和範圍範圍參數HRRORDRR0|R34767R43224|R47319D0|D7999控制字OOO控制字透過定義的位址,來讀取寫入設定和查看狀態。暫存器的數值功能0等待操 - [第15章 進階及電源擴充外型尺寸圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-15/): 15-1 電源模組外型尺寸圖15-1-1 MPA024-24外型尺寸圖MPA024-24外型尺寸圖15-1-2 MPA048-24外型尺寸圖MPA048-24外型尺寸圖 - [第16章 高速擴充外型尺寸圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-16/): 16-1 高速通訊模組外型尺寸圖16-1-1 MHCM22外型尺寸圖MHCM22外型尺寸圖16-1-2 MHCM55外型尺寸圖MHCM55外型尺寸圖16-1-3 MHCM25外型尺寸圖MHCM25外型尺寸圖 - [第17章 本地I O擴充模組外型尺寸圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-17/): 第17章 本地I/O擴充模組外型尺寸圖17-1 數位輸入模組外型尺寸圖17-1-1 M16X外型尺寸圖M16X外型尺寸圖17-2 數位輸出模組外型尺寸圖17-2-1 M16YT / M16YJ / M16YR外型尺寸圖M16YT外型尺寸圖M - [第18章 I O Bus延伸模組外型尺寸圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-18/): 第18章 I/O Bus延伸模組外型尺寸圖18-1 中繼模組外型尺寸圖18-1-1 MRPWE-AC 外型尺寸圖MRPWE-AC 外型尺寸圖18-2 I/O Bus 延伸模組(頭部/尾巴模組)外型尺寸圖18-2-1 MRGH外型尺寸圖MRG - [第19章 周邊與附件外型尺寸圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-19/): 19-1 牛角端子配線端子台外型尺寸圖19-1-1 MFT40T外型尺寸圖MFT40T外型尺寸圖19-2 高密度DIO連接線外型尺寸圖19-2-1 MFW40I-50外型尺寸圖MFW40I-50外型尺寸圖19-2-2 MFW40N-150外 - [第1章 擴充模組一覽表](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-01/): 擴充模組一覽表分類/品名型號規格電源擴充電源模組MPA024-24電源供應器,輸入 :100~240VAC(50/60Hz),輸出 :24VDC 1A( 內部及外部共用 ),功率 24WMPA048-24電源供應器,輸入 :100~240V - [第20章 檢修和保養](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-20/): 20-1 注意事項進行各項維護保養時,請注意以下事項,錯誤或不慎的操作將可能造成人員與設備的傷害。⚠請確認周遭環境並非暴露於腐蝕性物質(例如氯化物與硫化物氣體)及易燃性物質(例如油霧與切削粉末)或灰塵堆積處,避免PLC系統故障或引起火災。⚠ - [第2章 M系列PLC之擴充](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-02/): M系列PLC之擴充係指當M系列CPU模組所提供之資源不敷使用或CPU模組未提供之介面時,可藉由擴充模組之附加,來擴充其I/O數目或介面種類,M系列PLC之擴充可分為幾大類,包括本地I/O擴充,高速擴充,Plug in擴充及進階擴充...等。 - [第3章 安裝與接線](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-03/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第4章 電源配線&功率消耗計算及電源時序要求](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-04/): M系列PLC電源模組有兩種電源,第一為CPU專用之24VDC電源(供給CPU模組和擴充模組),第二為外部Sensor 之24VDC電源。CPU模組和擴充模組也分為兩種電路,第一為內部24VDC電路,第二為外部24VDC Sensor電路。內 - [第5章 數位輸入電路](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-05/): M系列PLC之數位輸入採用共點(Common)方式之24VDC單端共點輸入電路結構。單端共點輸入電路又有高速、中低速、兩反應速度。單端共點輸入電路需藉由PLC內部共點端子S/S及輸入元件之外部共線的接線變化來變換為SINK輸入方式或SOUR - [第6章 數位輸出電路](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-06/): 6-1 數位輸出電路規格數位輸出電路規格表項目規格單端共點電晶體輸出單端共點繼電器輸出高速中速最大輸出頻率200KHz1kHzON/OFF用,不適合作頻繁交換用途工作電壓5~30VDC<250VAC,30VDC最大負載電流電阻性0.1 - [第7章 進階及電源擴充模組規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-07/): 7-1 電源模組規格 M系列PLC之專用電源模組提供一定的功率給CPU模組和擴充模組使用,若是較多擴充模組之PLC系統,可以在每個分支的起始位置安裝電源模組來供給後續之擴充模組使用。7-1-1 MPA024-24規格各部位名稱和功能MPA0 - [第8章 Plug-in 擴充板規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-08/): 8-1 通訊板M系列PLC之通訊板係指當M系列CPU模組所提供之通訊資源不敷使用時,可藉由Plug-in 擴充板之附加,來擴充其通訊功能。8-1-1 MB-CB2規格各部位名稱和功能MB-CB2各部位名稱技術規格MB-CB2技術規格表項目技 - [第9章 高速模組規格](https://resource.fatek.com/index.php/2026/11/17/mplc-m02-zh-09/): 9-1 高速通訊模組M系列PLC之高速通訊擴充模組係指當M系列CPU模組所提供之通訊資源不敷使用時,可藉由擴充模組之附加,來擴充其通訊功能。9-1-1 MHCM22規格各部位名稱和功能MHCM22各部位名稱技術規格MHCM22技術規格表項目 ## 硬體篇 - [第10章 FBs-PLC 之高速計數器與高速計時器](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-010/): 10.1 FBs-PLC之高速計數器 一般PLC之軟體計數器之計數頻率僅能達數十Hz(視掃描時間而定),若超過將產生漏數甚至完全無法計數,此時必須使用高速計數器(High-Speed Counter簡稱HSC)才能勝任。一般 PLC之高速計 - [第11章 FBs-PLC 之NC 定位控制](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-011/): 早期使用一般馬達來作定位控制,由於速度不快、或者精度要求不高,所以足以應付所需;當機械運轉為了求取效率而將速度加快時,當製成品品質、精度要求愈高時,馬達停止位置之控制就不是一般馬達所能勝任了!解決此問題之最佳方案是採用NC定位控制器搭配步進 - [第12章 FBs-PLC 之通訊](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-012/): FBs-PLC主機內建有一個通訊埠界面Port0(USB或RS232介面)。若添購通訊板(CB)則可加增為二~三個通訊埠界面(依通訊板之型號而定),若仍不夠使用的話,可再加裝通訊模組(CM),至多可將通訊埠界面擴增為五個(PORT0~POR - [第13章 FBs-PLC CLINK 與Modbus 通訊功能之應用](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-013/): FBs-PLC可藉由Port 1、2、3或4等四個通訊埠來作永宏多台CPU LINK連線或與具有RS-232/RS-485通訊介面之智慧型週邊透過通訊方式作連線整合應用。 除了上述功能之外,Port1~Port4亦可透過FUN150指令指定 - [第14章 ASCII 檔案輸出功能之應用](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-014/): FBs-PLC之ASCII輸出功能可讓PLC直接驅動ASCII輸出裝置如印表機、終端機等設備而印出或顯示諸如生產報表、需料明細、警告訊息等中/英文文件資料或顯示畫面。ASCII檔案輸出功能之應用需將欲輸出之ASCII檔案資料編輯成符合FUN - [第15章 萬年曆(RTC)](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-015/): FBs-PLC之MN/MC主機內建有萬年曆時鐘(Real Time Clock),無論在PLC供電或斷電情況下,RTC均可正確計時。其所提供之時間數據有週、年、月、日、時、分、秒等7種時間值資料。使用者可利用此萬年曆時鐘來作終年無休之24小 - [第16章 七段/十六段(米字型)LED 顯示器模組](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-016/): 16.1 FBs-7SG概述FBs-7SG有7SG1與7SG2二種機型,其內部分別具有1個或2個可顯示8個數字(位數)之顯示IC,可分別驅動8個或16個共陰極連接之七段LED顯示器;或驅動4或8個16段米字型LED顯示器,下圖係以FBs-7 - [第17章 指撥開關輸入模組](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-017/): FBs-32DGI係FBs-PLC系列之多工指撥開關輸入模組。一片32DGI模組可提供多達32組之指撥開關輸入或128個開關點輸入。由於採用專用I/O控制晶片的緣故運作時不必由PLC之CPU逐次多工掃描,因此模組更新速率與CPU掃描時間無關 - [第18章 類比輸入/出(AIO)擴充模組](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-018/): 18.1 FBs-6AD類比輸入模組FBs-6AD係FATEK FBs系列PLC之類比輸入信號擴充模組,其提供6通道14或12位元分解能力之類比至數位轉換功能,應用時可利用模組內之跳線設定來配合量測不同信號型態及振幅之外接類比信號,不論14 - [第19章 類比入/出(AIO)擴充板](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-019/): FBs系列主機因14點以下之機型未提供右側擴充模組之輸出/入界面,因此當使用14點以下主機時便無法使用類比模組,有鑒於此永宏特別開發出一系列類比擴充板,包含類比輸入擴充板(FBs-B4AD)、類比輸出擴充板(FBs-B2DA)以及類比輸入/ - [第1章 FATEK FBS 系列 PLC 簡介](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-001/): 【硬體篇】FATEK FBS 系列PLC簡介永宏FATEK FBS系列PLC為一外型小巧卻具媲美中大型PLC功能之新一代小型PLC,其通訊埠最多5個,最大I/O為數位輸入(Digital Input,簡稱DI)256點,數位輸出(Digit - [第20章 溫度量測模組及溫度PID 控制](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-020/): FBs-PLC為因應廣大之溫控應用市場,提供了最常用之熱電偶(TC)、白金電阻(RTD)及溫度可變電阻體(NTC)等參大類共六種溫度量測模組;其中FBs-2TC/FBs-6TC/FBs-16TC等三種溫度模組可作2點、6點及16點等熱電偶輸 - [第21章 類比輸入(AI)+溫度量測混合模組](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-021/): FBs-PLC為因應實際使用者之應用需求提供了一個結合溫度與類比輸入量測之經濟組合模組。簡單來說其綜合單獨之溫度模組及類比輸入模組之所有特性。因此其設定與操作方法與單獨之溫度模組及類比輸入模組完全一致不同的僅是可量測之通道數不一樣而已。2A - [第22章 FBs-PLC 之泛用PID 控制](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-022/): 22.1 PID控制簡介一般常見之程序控制應用,只要控制元件加工精度夠或是控制反應之重現性夠好,開迴路控制已可滿足大部份之應用需求,而且簡單容易、成本低廉是最大優點;但隨著使用時間、元件特性變化或受控負載或外界工作環境之變異,開迴路控制因為 - [第2章 系統之組成(System configuration)](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-002/): 第2章系統之組成(System configuration) 2.1 FBS-PLC之單機系統智慧型週邊Load Cell基地台數位I/O擴充機/模組DI 人機FBS-24XY FBS-40XY FBS-60XY 條碼機乙太網路(Port4 - [第3章 FBS-PLC 之擴充](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-003/): FBS-PLC之擴充係指當FBS-PLC主機所提供之資源不敷使用或主機未提供之界面時,可藉由擴充機/模組之附加,來擴充其I/O數目或界面種類,FBS-PLC之擴充可分為I/O擴充及通訊埠擴充兩大類。 3.1 I/O擴充FBS-PLC之I/O - [第4章 安裝須知](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-004/): •危險1. 在安裝或拆卸FBS-PLC主機、擴充機及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。2. 在完成所有安裝配線作業後,必須將端子台之保護蓋板裝上, - [第5章 電源供應器配線、功率消耗計算及電源時序要求](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-005/): FBS-PLC內部有三種電路,第一為5VDC之邏輯電路,第二為24VDC之驅動電路(驅動輸出元件,如繼電器、電晶體…等),第三為24VDC之輸入電路。除第一、第二種電路之電源必須由主機/ 擴充機內建之電源供應器或由擴充模組專用之擴充電源供應 - [第6章 數位輸入(DI)電路](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-006/): FBS -PLC之數位輸入有5VDC超高速雙端獨立輸入(即一輸入點佔兩個端子,不必和其他輸入點共用端子)及為節省端子數目而採用共點(Common)方式之24VDC單端共點輸入等兩種電路結構。單端共點輸入電路又有高速、中速、低速等三種反應速度 - [第7章 數位輸出(DO)電路](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-007/): FBS -PLC之數位輸出有5VDC 差動輸出(Line-driver)之超高速雙端輸出(即一輸出點佔用兩個端子)及為節省端子而採用共點(Common)方式之單端共點輸出兩種電路結構。而單端輸出之輸出元件則有繼電器及電晶體兩種,其中繼電器因 - [第8章 試俥、監視與維護](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-008/): •警告在維護過程中,需要接觸到PLC之任何端子,或插入、拔取零組件(如擴充排線等)均需切斷PLC之輸入電源,如在通電中進行,將可能造成觸電、短路、損壞PLC或造成PLC誤動作。 8.1 配線完畢之首次送電前檢查1. 送電前清潔所有線屑、螺絲 - [第9章 FBs-PLC 之中斷](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-009/): 9.1中斷之原理與架構FBs-PLC所需執行之工作繁複眾多,有20K Words的使用者程式要解析,512點I/O狀態要抓取或更新,有5個通訊埠需服務… ,但CPU只有一個,故任一時間只能執行一項工作,因此PLC只能依序地將上述所有工作由第 - [附錄一 FATEK 通訊協定](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-101/): 本通訊協定(Protocol)是永宏PLC主機上各通訊埠在標準通訊模式下均適用之通訊協定,任何對PLC之資料存取(自PLC內部讀出或由外界寫入PLC)或運作、控制等,除在硬體連線及通訊參數設定必需通訊雙方一致外,在通訊訊息格式(Messag - [附錄二 PWMDA 類比輸出模組使用說明](https://resource.fatek.com/index.php/2026/11/17/fbs-hw-zh-102/): FBs系列主機雖已有類比擴充模組,但為顧及僅有單點類比輸出需求之顧客,特別再開發PWMDA類比輸出模組已因應不同場合之各類需求。 FBs PWMDA利用脈波輸出寬度調變原理,配合週邊輸出電路,可將不同波寬之數位信號轉換為相對應之類比輸出電壓 ## 結構化語言 ST 手冊 - [前言](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-zh-00/): 前言請在使用本產品前閱讀並確實瞭解本手冊之內容後再行使用。如若有任何疑問或意見,請洽詢FATEK代理經銷商保固內容和責任限制。使用本產品注意事項符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所 - [第1章 認識結構化語言ST](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-zh-01/): 1-1 ST語言的特點早期的自動化控制在編輯可程式邏輯控制器邏輯時,須透過書寫器將類似組合語言的程式簡碼指令 (Mnemonic )輸入控制器中,已達到專案所需求的動作,後續隨著工業環境演變,開發出了控制迴路階梯圖 (LD) 來表達程序的邏 - [第2章 Uperlogic ST 使用者介面](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-zh-02/): 2-1 介面概觀A: 雙擊程式名稱會跳出編輯畫面B: 1. 顯示目前可以使用的ST語法,以及可呼叫使用的FCM程式, 雙擊該欄位, 會插入對應的樣板在程式裡頭 2. 顯示的如果呈現反灰,代表該指令不能用在當前的文本中 3. 右側邊界可以拖動 - [第3章 Uperlogic ST的程式基本架構](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-zh-03/): 3-1 簡介本章對使用基本ST語言編寫程式的方法進行說明。3-1-1 字元編碼ST 編輯器支持Unicode(encode in UTF-8)多國語言。支援程式編輯中出現的日語、英語、中文等多種語言的基本字元及大部分符號,除了可以用于註解外 - [第4章 ST編輯環境支援函示列表](https://resource.fatek.com/index.php/2026/11/17/mplc-m05-zh-04/): 4-1 Ladder與ST編輯環境函示的名稱對照ST指令名稱參數指令手冊對應資訊備註編號名稱ToBCDToBCD_DS,DFun20BCDToBIN ToBIN_DS,DFun21BINF_TRIGS,DFun4DIFUR_TRIGS,DF ## 軟體使用手冊 - [前言](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-00/): 本手冊用於說明使用FATEK M系列PLC CPU 模組時之必要資訊,請在使用本產品前閱讀並確實瞭解本手冊之內容後再行使用。如若有任何疑問或意見,請洽詢FATEK代理經銷商保固內容和責任限制。保固內容FATEK的產品保固期是指產品自售出起約 - [第10章 模組配置](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-10/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第11章 通訊功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-11/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第12章 監控功能](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-12/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第13章 安全性](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-13/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第14章 工具](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-14/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第1章 簡介](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-01/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第2章 安裝說明](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-02/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第3章 Uperlogic介紹](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-03/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第4章 專案管理](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-04/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第5章 系統參數](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-05/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第6章 程式建立](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-06/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第7章 程式建立](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-07/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第8章 註解和標籤資訊](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-08/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 - [第9章 運動控制](https://resource.fatek.com/index.php/2026/11/17/mplc-m04-zh-09/): ⚠危險在安裝或拆卸M系列CPU模組及各種擴充模組或其所連接之設備時,必須將所有電源全部關閉,否則可能造成觸電或引起錯誤動作,造成死亡或嚴重之人身傷害及損壞機器設備。在安裝,配線施工未完成前,切勿將PLC散熱孔上之防塵紙撕下,以防止施工時之鑽 ## 運動控制使用手冊 - [使用本產品注意事項](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-00/): 符合應用之條件FATEK 的產品適用評估並安裝於經過全面設計的設備或系統。請使用者自行確認目前所使用的系統、機械或是裝置是否適用於FATEK產品。如未確認是否符合或適用時,本公司無須對產品的適用性負責。如客戶要求,FATEK 將提供相應的第 - [第10章 原點復歸](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-10/): 使用者採用相對式 Encoder 作為位移偵測器之機台,通常皆需要作歸零動作以作為定位座標之參考,此動作稱為機械原點復歸(尋找機械零點)。NC 伺服機台之機械原點復歸模式簡圖如下:10-1 模式 100: 正向-下緣觸發動作說明歸零起始點在 - [第11章 JOG(吋動)模式](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-11/): JOG(吋動功能), 本產品提供Fun180可讓使用者可以快速的完成伺服吋動功能。下方將進行Fun180 MFJog的相關說明,使用者也可以透過6-8章節了解此Function的資訊。Fun180. MFJog參數解釋階梯圖符號EN = 1 - [第12章 即時趨勢圖](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-12/): 滑鼠點選專案管理列〔運動控制〕→〔運動連結設定〕→〔滑鼠右鍵〕→〔即時趨勢圖〕;或於功能列圖示選單中選取〔PLC〕→〔即時趨勢圖〕;或於功能列圖示選單中選取〔PLC〕→〔運動工具〕→〔即時趨勢圖〕圖 1 運動即時趨勢圖以下為即時趨勢圖開啟後 - [第13章 試運行 (Test Run)](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-13/): 試運行(Test Run)為 UperLogic 特有的運動控制功能,為標準內建功能。M-PLC 控制器在運行 Motion 運動控制上,可由三個方式達成: 1. Ladder 控制/2. 運動流程 /3. Test Run。其中若為初次使 - [第14章 手搖輪模式](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-14/): 手搖輪主要是控制用來放大輸入軸的脈波數,在使用手搖輪功能時,使用者須先設置 EtherCAT 手搖輪輸入點 X0~X15 於高速計數 HSC0~HSC7。使用者可以在【I/O 組態】 > 【高速計數器】 > HSC0 ~ HSC - [第15章 速度控制及扭矩控制](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-15/): 本章節將對 M-PLC 速度控制及扭矩控制進行說明。速度控制及扭矩控制功能,無法由 PLC 調用,欲使用速度及扭矩控制。可透過運動流程功能塊或階梯圖指令使用。速度控制及扭矩控制是將 M-PLC 設定為速度/扭矩控制模式時啟用的功能。15-1 - [第16章 同步控制、飛剪、追剪(同步功能參數表 電子凸輪設定](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-16/): 第16章 同步控制、飛剪、追剪(同步功能參數表/電子凸輪設定本章節主要介紹同步控制的基本使用與參數設定,同步控制功能也是軸運動控制功能的一種,可有效的應用在龍門機構,追飛剪機台等應用。是位置控制模式下的一種非常有效的功能16-1何謂同步控制 - [第17章 Motion警報列表](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-17/): FATEK M-PLC 警報列表主要分為三大類,分別為運動流程的錯誤警報、EtherCAT通訊錯誤警報以及軸狀態的錯誤警報。以上三大類的錯誤會放在各自的特殊暫存器。17-1運動流程 警報運動流程的錯誤警報可分為ID 1 ~ ID 16 運動 - [第18章 Motion探針](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-18/): 探針功能用於精確捕捉軸的位置或在運動過程中檢測特定事件。18-1探針編號設定觸發驅動器探針功能的模式。探針透過外部DI信號、Z向訊號,並根據使用者設定上緣或下緣觸發實時鎖存伺服軸或編碼器的值0: 關閉1: 使用外部訊號輸入2: 使用編碼器Z - [第19章 Motion範例應用](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-19/): 19-1中斷定長背景研磨機是一種常見的磨削工具,它是利用砂輪在高速旋轉時將待加工物料表面磨削或切割,從而達到加工和修整的目的。研磨機主要由電動機、砂輪、砂輪承托、支撐臂、防護罩等部件組成。砂輪是研磨機最關鍵的部件,它的材質、形狀、尺寸和磨粒 - [第1章 M-PLC運動控制單元概要](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-01/): 本章節將介紹M-PLC 運動控制功能與概要。M-PLC提供通訊型EtherCAT 軸運動控功能,可控制最多16軸之控制應用。並且也提供最多8軸的脈衝型式運動控制。在程式編程上,M-PLC提供在階梯圖調用運動控制功能,也可編寫運動流程控制並調 - [第2章 運動參數和狀態(特殊暫存器和繼電器區域)](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-02/): 本章節將介紹M-PLC 內部之記憶體配置與暫存器明細,運動控制暫存器 範圍從R36880為起始暫存器,Relays範圍從M10512開始。類型起始位址每軸或每組大小運動控制系統暫存器 (word)RR36880運動控制軸暫存器 (word) - [第3章 EtherCAT功能和配置](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-03/): 本章節將說明EtherCAT功能與配置,EtherCAT由德國 Beckhoff Automation 公司開發之工業乙太網路技術。連接類型為一個主站與多個從站的網路系統。透過EtherCAT 從站資訊(ESI)為基礎的配置工具。目前PDO - [第4章 軸參數及設定](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-04/): 本章節講述M-PLC連結EtherCAT Servo所需的參數設定與軸連結設定等資訊。軸連結與軸參數設定皆可透過FATEK UperLogic程式編輯軟體來做設定。4-1運動連結設定執行UperLogic編輯軟體,左方視窗欄運動連結設定點開 - [第5章 點表和點參數](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-05/): 此章節說明運動點設定與參數。運動流程的運動點資訊如: 目標位置/最高速度/加減速及加速類型等. 都是由點表及點參數設定。欲使用PLC程式修改點表與點參數設定值內容,請詳閱第八章運動參數映射表。5-1運動點設定介面運動點設定由FATEK Up - [第6章 階梯圖運動指令](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-06/): M-PLC 控制器在實行Motion運動控制上,原則上透過運動流程與點表之配合來達到使用者運動順序控制,而在簡單的單軸點位運動、JOG 或 HOME。 M-PLC亦提供階梯圖運動方塊指令給使用者使用。M-PLC運動控制可由三個方式達成:1. - [第7章 運動流程介紹](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-07/): 此章節將會說明FATEK M-PLC特有的運動控制方法,命名為運動流程,其優勢在於運動控制流程能更完整的顯示、監控與設計。並能有效的達成設計者的邏輯控制與連續運動控制。運動流程 在使用時,可以與階梯圖程式同時運行,進行搭配使用。運動流程最多 - [第8章 定位控制與補間](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-08/): 此章節說明定位控制與補間功能。使用定位與運動控制功能時,可以照各軸將動作類型如動作模式、目標坐標、加減速度等或其它的設定如下一點編號、連續模式、轉移條件等。作為點參數的設定。點參數可以按各軸所需要的點數設定,使用者僅需更改指定的點編號,便可 - [第9章 運動參數映射表](https://resource.fatek.com/index.php/2026/11/17/mplc-m06-zh-09/): 9-1 運動參數映射表介紹運動參數映射表可讓使用者可在PLC Ladder程式中動態修改運動控制相關參數。使用者透過MFMapTbPrm,並指定暫存器並對應到欲修改的參數項目,即可達到PLC Ladder程式中動態修改相關的運動參數。目前運