Item

ERR1/ERR2 LED

SR/MASK

Not enough memory capacity

ON/ON

Reserve

Initialization error

ON/ON

Reserve

System error

ON/ON

Reserve

System stack error

ON/ON

R35361/0x0200

System check code error instruction

ON/ON

R35361/0x0004

Power-on detection for power-off operation

ON/ON

R35360/0x0400

System check code error instruction

ON/ON

R35362/0x3E00

Expansion module detection error

ON/OFF

R35360/0x0001

Expansion module configuration error

ON/OFF

R35360/0x0002

The number of expansion modules does not match the CPU Unit project

ON/OFF

R35360/0x0004

Expansion module I/O points out of range

ON/OFF

R35360/0x0008

The number of expansion modules out of range

ON/OFF

R35361/0x0100

Motion control unit queue error

ON/OFF

R35360/0x0080

Motion control unit overflow error

ON/OFF

R35360/0x0100

Motion control unit emergency stop

ON/OFF

R35360/0x0200

Watchdog restart detection

ON/OFF

R35361/0x0010

Illegal memory card detection instruction

OFF/ON

R35360/0x0010

Memory card operation error detection

OFF/ON

R35360/0x0020

PLC ID dose not match PROG ID

OFF/ON

R35360/0x0040

The application exceeds the capabilities of this CPU

OFF/ON

R35361/0x0800

System service error instruction

OFF/ON

R35361/0x8000