Motion Probe
The probe function is used to precisely capture the position of an axis or detect specific events during motion.
18-1 Probe Number
The touch probe triggers through an external DI signal of the drive or Z signal of the encoder, based on the user’s configuration of either the rising or falling edge.
0: Off
1: Input with external signal
2: Use encoder Z-phase signal
18-2 Probe Mode
0: Single trigger, Rising trigger
1: Continuous trigger, Rising trigger
2: Single trigger, Falling trigger
3: Continuous trigger, Falling trigger
18-3 Information of Probe Register
Special registers and special relays used for the probe function.
|
No. |
Name |
Description |
|
M10617+ 40*(n-1) |
Axis Probe 1 Function ON |
High Pos: ON |
|
M10618+ 40*(n-1) |
Axis Probe 1 Function Reset |
Rising Trigger |
|
M10619+ 40*(n-1) |
Axis Probe 2 Function ON |
High Pos: ON |
|
M10620+ 40*(n-1) |
Axis Probe 2 Function Reset |
Rising Trigger |
|
M11262+ 40*(n-1) |
Axis Probe 1 Triggering Status |
High Pos: Status ON Low Pos: StatusOFF |
|
M11263+ 40*(n-1) |
Axis Probe 2 Triggering Status |
High Pos: Status ON Low Pos: StatusOFF |
|
DR37042+ 150*(n-1) |
Axis Driver Probe 1 Coordinates |
Displays probe coordinates for axis drive feedback |
|
DR37044+ 150*(n-1) |
Axis Driver Probe 2 Coordinates |
Displays probe coordinates for axis drive feedback |