2.1 Ratings and Specifications

2.1.1 Ratings
■ 1-phase 220VAC / 3-phase 220VAC
◆ SC303AAD▯▯ / SC306AAF▯▯ / SC308AAG▯▯ / SC310AAH▯▯

Model

03A

06A

08A

10A

Continuous Output Current [Amps]

3

6

8

10

Instan. Max. Output Current [Amps]

10

14

21

23

Main Circuit

Power Supply

1-phase / 3-phase
AC 220V

3-phase AC 220V,-15% ~ +10%, 50 Hz / 60 Hz*1

Input Current [Amps]

1.9

3.9

5.4

6.3

Control Power Supply

1-phase AC 220V,-15% ~ +10%, 50 Hz / 60 Hz

Power Supply Capacity [kVA]

1.3

1.7

2.4

2.8

Regenertative Resistor

Bulit-in
Regenertative Resistor

Resistance [Ω]

-*2

40

40

40

Capacity [W]

–

80

80

80

Min. Allowable External Resistance [Ω]

30

15

12

12

Overvoltage Category

Ⅲ

*1: If use 1-phase AC220V for power supply, the current output may not meet the spec. *2: 03A servo driver have no bulit-in regenerative resistor.

■ 3-phase380VAC
◆ SC303ADE▯▯ / SC306ADH▯▯ / SC310ADI▯▯ / SC315ADK▯▯ / SC328ABL▯▯

Model

03A

06

10A

15A

28A

Continuous Output Current [Amps]

3

6

10

15

28

Instan. Max. Output Current [Amps]

8.5

14

45

45

63

Main Circuit

Power Supply

3-phase AC 380V,-15% ~ +10%,
50 Hz / 60 Hz

Input Current [Amps]

3

5.9

9.7

15.5

24.8

Control Power Supply

DC 24V,-10% ~ +10%, 50W

1-phase AC 380V,-15% ~+10%,
50 Hz / 60 Hz

Power Supply Capacity [kVA]

2.0

3.9

7.8

12.4

19.8

Regenertative Resistor

Bulit-in
Regenertative Resistor

Resistance [Ω]

40

40

40

32

-*1

Capacity [W]

80

80

40

150

–

Min. Allowable External Resistance [Ω]

30

30

30

20

15

Overvoltage Category

Ⅲ

*1: 28A servo driver have no bulit-in regenerative resistor.

2.1.2 Specifications

Item

Specification

Control Method

Position mode、JOG mode、speed mode…etc

Feedback

Serial encoder:17bits or 23bits(incremental encoder / absolute encoder)

Environment Conditions

Operation Temp.

0~+50℃

Storage Temp.

-20~+85℃

Environment Humidity

90% relative humidity max. (with no freezing or condensation)

Storage Humidity

90% relative humidity max. (with no freezing or condensation)

Vibration Resistance

4.9m/s2

Shock Resistance

19.6m/s2

Mounting

Base-mounted

Performance

Speed Control Range

1:10000(At the rated torque, the lower limit of the speed control range must not cause the Servomotor to stop.)

Speed Response Freq.

3.1KHz

Coefficient of Speed Flucuation

±0.01% of rated speed max. (for a load fluctuation of 0% to 100%)

0% of rated speed max. (for a voltage fluctuation of ±10%)

±0.1% of rated speed max. (for a temperature fluctuation of 25°C±25°C)

Speed Control

Reference Voltage

DC±10V

Input Impedance

Approx. 20KΩ

Circuit Time Constant

47us

Torque Control

Reference Voltage

DC±10V

Input Impedance

Approx. 20KΩ

Circuit Time Constant

47us

Digital Input

Number of points

8

Input Signals That Can Be Allocated

Servo ON(/S-ON)*1、Proportional Control(/P-CON)*1、Forward Drive Prohibit(P-OT)、Reverse Drive Prohibit(N-OT)、Alarm Reset(/ALM-RST)、Forward External Torque Limit(/P-CL)、Reverse External Torque Limit(/N-CL)、Position Deviation Clear(/CLR)、Internal Setup Speed Switch…etc
A Signal can be allocated and positive and negative logic can be changed.

Digital Output

Number of points

6

Output Signals That Can Be Allocated

Servo Alarm(ALM)、Position Completion(/COIN)、Speed Coincidence Detection(/V-CMP)、Rotation Detection(/TGON)、Servo Ready(/S-RDY)、Torque Limit Detection(/CLT)、Brake(/BK)、Encoder Origin Output(PGC) A Signal can be allocated and positive and negative logic can be changed.

Encoder Divided Pulse Output

Phase A, phase B, phase Z: Line-driver output
Number of divided output pulses: Any setting is allowed.

RS-485 *1
Communication

Protocal

MODBUS

1:N Communications

Up to N=127 stations

Axis Address Setting

Set with parameters

EtherCAT
Communication

Protocal

CoE (CANOpen over EtherCAT)

Control Mode

csp, pp, hm, csv, cst, pv, tq

Homing Method

1-14, 17-30, 33, 34, 35, 37

Synchronization Mode

DC, SM2, FreeRun

Cycle Time

125us

Displays/Indicators

CHARGE indicator and five-digit seven-digit display

Regenerative Processing

Built-in (An external resistor must be connected to 220V_03A & 380V_28A)

Overtravel(OT)Prevention

Stopping with dynamic brake (DB), deceleration to a stop, or coasting to a stop for the P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Prohibit) signal

Protective Function

Overcurrent, overvoltage, low voltage, overload, regeneration error, etc.

Monitoring Functions

Speed, Current position, Reference pulse count (accumulated), Position deviation, Motor current, Operating status, Input/output signals

Utility Functions

Gain adjustment, alarm history, jogging, origin search, etc.

Intelligent Functions

Bulit-in Auto-tuning function

Applicable Load Inertia

Less than 5 times the motor inertia

Position

Feedforward Compensation

0~100%(Setup Unit1%)

Reference Pulse Form

One of the following is selected:
Pulse+Direction (P/R)pulse trains, CW+CCW(U/D)pulse trains, and two-phase pulse trains with 90 degree phase differential

Input Form

Line driver or open-collector

Max. Input Frequency

•Line Driver
Pulse+Direction (P/R)pulse trains, CW+CCW(U/D)pulse trains: 500K pps two-phase pulse trains with 90-degree phase differential: 500K pps
•Open-Collector
P Pulse+Direction (P/R)pulse trains, CW+CCW(U/D)pulse trains: 200K pps two-phase pulse trains with 90-degree phase differential: 200K pps

*1: Only support pulse type model

2.2 SC3 External Dimensions

◆ 220V: SC303AAD▯▯

◆ 220V: SC306AAF▯▯
380V: SC303ADE▯▯

◆ 220V: SC308AAG▯▯ / SC310AAH▯▯
380V: SC306ADH▯▯ / SC310ADI▯▯

◆ 380V: SC315ADK▯▯

◆ 380V: SC328ABL▯▯

Was this page helpful?