13.1 The selection and calculation method for regenerative resistors.

When the direction of the motor’s torque and speed is opposite, the power generated from the load side will be

transmitted back to the drive, and the regenerative resistors is needed to dissipate the rally power to avoid drive failure.

1. Find the inertia and speed of the servo Motor according to the table below

Voltage

Motor Wattage

Rated speed (rev/min)

motor inertia (×10-4 Kg*m2)

AC 220V

100W(brakeless)

3000

0.067

100W(braked)

3000

0.067

200W(brakeless)

3000

0.26

200W(braked)

3000

0.28

400W(brakeless)

3000

0.49

400W(braked)

3000

0.51

750W(brakeless)

3000

1.51

750W(braked)

3000

1.71

1KW(brakeless)

2000

13.88

1KW(braked)

2000

15.78

1.5KW(brakeless)

2000

18.57

1.5KW(braked)

2000

20.24

2KW(brakeless)

2000

23.69

2KW(braked)

2000

25.36

AC 380V

400W(brakeless)

3000

0.49

400W(braked)

3000

0.51

750W(brakeless)

3000

1.51

750W(braked)

3000

1.71

1KW(brakeless)

1500

16.04

1KW(braked)

1500

17.71

2KW(brakeless)

2000

23.69

2KW(braked)

2000

25.36

2.9KW(brakeless)

1500

56.8

2.9KW(braked)

1500

65.3

4KW(brakeless)

2000

56.8

4KW(braked)

2000

65.3

5.5KW(brakeless)

2000

78.2

5.5KW(braked)

2000

86

7.5KW(brakeless)

1500

130

7.5KW(braked)

1500

140

13KW(brakeless)

1500

272.8

15KW(brakeless)

1500

248

2. Calculate the rotational energy(ES) generated during servo operation using the formula.

ES = J × (nM)2/182 (Joules)
J = JM + JL
JM:Servo motor moment of inertia (kg·m2)
JL:Load moment of inertia at motor shaft (kg·m2)
nM:Servo motor operating motor speed (min-1)

3. Calculation Procedure for Regenerative Resistor Capacity

WK = ES /(0.2 × T)

Note: 1. The 0.2 in the equation for calculating WK is the value when the regenerative resistor’s utilized load ratio is 20%.

WK:Required regenerative resistor capacity (W)
ES:rotational energy
T:Servomotor repeat operation cycle (s)

If the value of WK does not exceed the capacity of the built-in regenerative resistor of the ServoDrive, an External Regenerative Resistor is not required. For details on the built-in regenerative resisters, refer to the ServoDrive specifications. If the value of WK exceeds the capacity of the built-in regenerative resistor, install an External Regenerative Resistor with a capacity equal to the value for W calculated above