Posted in

By

33 of 33Updated 2026-11-171 min read中文版

33.1 System Consistency Protection is Enabled

If the screen shows as below while using the HMI:

Figure 579 System Integrity Protection

33.1.1 Repairing File by Using Mini-USB Cable

Step 1: Connect PC and HMI by using mini-USB cable

Step 2: Open FvDesigner download function

Step 3: Check the【Firmware】to do update

Step 4: Make sure the HMI has enter to the system setting page then can download 【Running Package】normally.

Figure 580 Using mini-USB cable download to repair system integrity protection

33.1.2 Repairing File by Using USB Flash Disk

Step 1: Open FvDesigner and make a USB update file

Step 2: Check the “Include Recovery Settings” option then press “Start”

Step 3: Store the.uferp file into the USB flash disk

Step 4: Plug the USB flash disk into the HMI when the HMI is under recovery mode then it will start repairing automatically after a few seconds.

Figure 581 Using USB flash disk to download repair system integrity protection

To repair file by using USB flash disk, need to notice the following points:

  1. The HMI OS version need to be 2.0.12 or above
  2. When the HMI and FvDesigner are doing other functions by using the mini-USB cable, then the update will stop.
  3. If the USB flash disk has no .uferp or more than one .uferp files, then the update will stop.
Was this page helpful?