Before using the FATEK IoT service, please request an application form from your distributor. Once you receive the activation confirmation, you can start using the service.
|
Web |
FATEK IoT (GCP) |
|
|
Web |
FATEK IoT (Alibaba Cloud) |
|
|
App |
Google Play |
|
|
App |
App Store |
Upon receiving the email, please click the link within 7 days. If you haven’t received the email, please check your spam folder. If the link expires, please contact your distributor for reissuance.

2.1 HMI Setting
FATEK HMI supports the use of both “iMonitor” and “iAccess.” Below is an overview of the device login process:
Step 1.
To access the system settings of the HMI and navigate to the “Server/IoT” page, follow these steps:

Step 2.
Switch to the IoT tab and check the box for “Enable IoT Services.”

Step 3.
You need to input the HWID on the web and the LID on the HMI. Here are two methods to do so.
2.1.1 Manually
After logging into the webpage, click on “Devices” then select “Add New”

Here, you need to enter the “Name”, choose the “Product type”, input the “Service password”, and enter the “Hardware ID”. After filling out these fields, you need to click “Save” at the bottom of the webpage.
◆ Service Password:Should match the one entered on the HMI.
◆ Hardware ID:The HWID displayed on the HMI.

Back on the HMI, to use the iAccess feature, you need to purchase an “LID” (License ID). Upon purchase, you will receive either a physical product or an email containing a serial number. Once you have the serial number, please check the box for “Enable iAccess” and input the LID.
◆ Once activated, the LID will bind to the HWID and cannot be used with other HMIs.。
◆ The LID does not need to be entered on the webpage.

2.1.2 Using the App
Open the app and follow the steps shown in the image below. Click on the specified step, and the camera will appear.

After entering the “Service Password” on the IoT page, click on the image on the right side. It will generate a QR code. Please scan it using the app.

After scanning is complete, press “OK” in the top right corner of the HMI to save. The app will automatically fill in the HWID, Service password, and Product type. After entering the Name, click on the checkmark in the top right corner to add this device.
When adding an LID, you need to switch to the iAccess Page. Once in the iAccess device library, click on the device on the right side to edit it.

When the device is in an online state, you can click on “Remote Set LID.”

Scanning the QR code on the physical product will automatically input the LID into the HMI.

Step 4.
Check the IoT page if a green icon. A green icon indicates that the connection is normal, while a red icon indicates an abnormality. You can click on the icon to view error messages.

2.2 FvRT with FATEK IoT
To make FvRT more convenient for users, starting from version V1.7.15_B25391, IoT is supported.
FvRT’s IoT supports both iMonitor and iAccess functions.
Note 1: When using iAccess Insight, only remote screen monitoring is supported.
Note 2: To use this feature, you need to purchase an IGU-FvRT manufactured after 2025/08/25.
2.2.1 Setup Steps
Step 1: Launch the FvRT application. You will see the IoT settings option on the screen.

The IoT enable setting for FvRT is stored on the computer. If multiple computers are to use IoT, each computer must open the settings page and check Enable.
Step 2: After confirming that the IGU-FvRT dongle is plugged into the computer, open the settings page. You will see the HWID of the dongle. After checking Enable, you can enter the Service Password and LID.

Step 3: In the account, add a new device. When entering the HWID on the Add Device page, set the Product Type to FvRT.

2.3 FBs-CMWLC Setting
|
Step 1. 【IoT Service】: Select the service and set up the password
|
|
Step 2. 【Diagnostics】→【Information】, write down the HWID and enter it later when the web terminal creates the device.
|
2.4 FBs-CBES Setting
|
Step 1. 【IoT Service】setting, write down the HWID and enter it later when the web terminal creates the device. |
|
Step 2. -Select the service and set up the password.
|
2.5 MPLC Configuration
Step 1. Launch UperLogic.exe and connect to the target MPLC.
Step 2. Click Server Configuration, switch to the IoT tab, enable iMonitor, and set the password.

Step 3. Enter Online Monitoring mode, then click Server Configuration again. Switch to the IoT tab and copy the HWID.
Note: The HWID is only displayed when the PLC is in Online Monitoring mode.


Step 4. Go to the IoT web portal. In the Devices library, click Add M-PLC, paste the HWID, and enter the same password configured in the MPLC.

Step 5. After the device has been created, power-cycle the MPLC. Return to UperLogic, enter Online Monitoring mode, and verify that the device status is Online.
Note: It may take approximately 30 seconds for the device to reconnect after restarting.

Tip: press ← → to switch chapters, Ctrl+K to search


