1-16 Name comparison between Ladder and ST editing environment instructions
|
ST function name |
Parameter |
Instruction manual corresponding information |
Remark |
|
|
Number |
Name |
|||
|
ToBCD ToBCD_D |
S,D |
Fun20 |
BCD |
|
|
ToBIN ToBIN_D |
S,D |
Fun21 |
BIN |
|
|
F_TRIG |
S,D |
Fun4 |
DIFU |
|
|
R_TRIG |
S,D |
Fun5 |
DIFD |
|
|
Timer |
EN,T,PV,IsTimeout |
T |
TIMER |
|
|
Counter Counter_L |
Pulse,clr,C,PV,IsUp |
C |
COUNTER |
|
|
ABS ABS_D |
D |
Fun28 |
ABS |
|
|
CRC16 |
S,N,D |
Fun31 |
CRC16 |
|
|
DIV |
Sa,Sb,D |
Fun14 |
DIVISION |
|
|
FtoI FtoI_D |
S,D |
Fun201 |
F->I |
|
|
FACOS_deg |
S,D |
Fun219 |
FACOS |
|
|
FACOS_rad |
S,D |
Fun219 |
FACOS |
|
|
FASIN_deg |
S,D |
Fun218 |
FASIN |
|
|
FASIN_rad |
S,D |
Fun218 |
FASIN |
|
|
FCOS |
S,D |
Fun210 |
FCOS |
|
|
FDIV |
Sa,Sb,D |
Fun205 |
FDIV |
|
|
FMUL |
Sa,Sb,D |
Fun204 |
FMUL |
|
|
FSIN |
S,D |
Fun209 |
FSIN |
|
|
FSQR |
S,D |
Fun208 |
FSQR |
|
|
FTAN |
S,D |
Fun211 |
FTAN |
|
|
FZCP |
S,Su,S1,INZ,ERR |
Fun207 |
FZCP |
|
|
ItoF ItoF_D |
S,D |
Fun200 |
I->F |
|
|
LCNV LCNV_D |
EN,Md,S,Ts,D,L |
Fun33 |
LCNV |
|
|
MEAN MEAN_D |
S,N,D |
Fun25 |
MEAN |
|
|
MLC |
EN,XY,Rs,Sl,Tx,Ty,Tl,D,OVR |
Fun34 |
MLC |
|
|
MUL |
Sa,Sb,D |
Fun13 |
MULTIPLICATION |
|
|
SUM SUM_D |
S,N,D |
Fun24 |
SUM |
|
|
BITRD BITRD_D |
S,N,OTB,ERR |
Fun40 |
BITRD |
|
|
BITWR BITWR_D |
INB,D,N,ERR |
Fun41 |
BITWR |
|
|
DBUF |
EN,ID,CH,D,DN |
Fun115 |
DBUF |
|
|
ReadSDMem |
EN,INC,Bk,Os,Pr,L,D,ERR |
Fun162 |
RD-MP |
|
|
ReadWriteFileReg ReadWriteFileReg_D |
EN,R_W,INC,Sa,Sb,Pr,L |
Fun160 |
RW-FR |
|
|
SWAP |
D |
Fun46 |
SWAP |
|
|
WriteSDMem |
EN,INC,S,Bk,Os,Pr,L,WR,ACT,ERR,DN |
Fun161 |
WR-MP |
|
|
ToASCII |
S,N,D |
Fun64 |
->ASCII |
|
|
ToBCD ToBCD_D |
S,D |
Fun20 |
->BCD |
|
|
ToBIN ToBIN_D |
S,D |
Fun21 |
->BIN |
|
|
ToHEX |
S,N,D |
Fun63 |
->HEX |
|
|
ToHMS |
S,D |
Fun62 |
->HMS |
|
|
ToSEC |
S,D |
Fun61 |
->SEC |
|
|
BintoGray BintoGray_D |
S,D |
Fun55 |
B->G |
|
|
DECOD |
S,Ns,Nl,D,D,ERR |
Fun57 |
DECOD |
|
|
ENCOD |
H_L,S,Ns,Nl,D,D_0,ERR |
Fun58 |
ENCOD |
|
|
GraytoBin GraytoBin_D |
S,D |
Fun56 |
G->B |
|
|
PID PID_D |
AM,BUM,D_R,Ts, SR,O_R,PR,WR,CCERR,HAL,LAL |
Fun30 |
PID |
|
|
PID2 |
EN,UPD,AM,D_R, ID,CH,SR,OutR,PR,WR,ERR |
Fun38 |
PID2 |
|
|
TPCTL2 |
EN,UPD,A_M,D_R, ID,CH,SR,PR,OriR, WR,ERR,ALM |
Fun99 |
TPCTL2 |
|
|
IMDIO |
D,N |
Fun74 |
IMDIO |
|
|
SPD |
EN,S,TI,D,OVF |
Fun83 |
SPD |
|
|
ACTimer_10MS ACTimer_10MS_D |
TIM,EN,CV,PV,TUP,NUP |
Fun87 |
T.01S |
|
|
ACTimer_100MS ACTimer_100MS_D |
TIM,EN,CV,PV,TUP,NUP |
Fun88 |
T.1S |
|
|
ACTimer_1S ACTimer_1S_D |
TIM,EN,CV,PV,TUP,NUP |
Fun89 |
T1S |
|
|
RSWDT |
Fun91 |
RSWDTF |
||
|
WDT |
N |
Fun90 |
WDT |
|
|
HSCTR |
CN |
Fun92 |
HSCTR |
|
|
HSCTW |
S,CN,D |
Fun93 |
HSCTW |
|
|
RAMP2 |
EN,Om,Ta,Td,Rt,Rc,WR,ACC,DEC |
Fun98 |
RAMP2 |
|
|
CLINK |
EN,PAU,ABT,Pt,MD,WR,ERR,DN |
Fun151 |
CLINK |
|
|
CMCTL |
EN,PAU,ID,Pt,Ts, MD,WR,ERR |
Fun156 |
CMCTL |
|
|
ModBUS |
EN,A_R,ABT,PT,SRWR,ACT,ERR,DN, |
Fun150 |
M-Bus |
|
|
NCR |
NE,SR,MD,WR,ACT,ERR,DN |
Fun152 |
NCR |
|
|
BKCMP BKCMP_D |
Rs,Ts,L,D |
Fun112 |
BKCMP |
|
|
BT_M BT_M_D |
Ts,Td,L |
Fun103 |
BT_M |
|
|
QUEUE QUEUE_D |
InOut,IW,Qu,L,Pr,OW,EPT,FUL |
Fun110 |
QUEUE |
|
|
T_Search T_Search_D |
FHD,DS,Rs,Ts,L,Pr,FND,END,ERR |
Fun105 |
R-T_S |
|
|
SORT SORT_D |
AD,S,D,L |
Fun113 |
SORT |
|
|
STACK STACK_D |
InOut,IW,ST,L,Pr, OW,EPT,FUL |
Fun111 |
STACK |
|
|
T_Compare T_Compare_D |
FHD,DS,Ta,Tb,L,Pr,FND,END,ERR |
Fun106 |
T-T_C |
|
|
T_Fill T_Fill_D |
Rs,Td,L |
Fun107 |
T_FIL |
|
|
ZoneWR |
Val,D,N |
Fun114 |
Z-WR |
|
|
MAND |
Ma,Mb,Md,L |
Fun120 |
MAND |
|
|
MBCNT |
OnOff,Ms,L,D |
Fun130 |
MBCNT |
|
|
MBRD |
EN,INC,CLR,Ms,L, Pr,OTB,END,ERR |
Fun126 |
MBRD |
|
|
MBROT |
L_R,Ms,Md,L,OTB |
Fun129 |
MBROT |
|
|
MBSHF |
INB,L_R,Ms,Md,L,OTB |
Fun128 |
MBSHF |
|
|
MINV |
Ms,Md,L |
Fun124 |
MINV |
|
|
MOR |
Ma,Mb,Md,L |
Fun121 |
MOR |
|
|
MXNR |
Ma,Mb,Md,L |
Fun123 |
MXNR |
|
|
MXOR |
Ma,Mb,Md,L |
Fun122 |
MXOR |
|
|
HSPSO |
EN,PAU,ABT,Ps,SR,WR,ACT,ERR,DN |
Fun140 |
HSPSO |
|
|
HSPWM |
EN,Pw,Op,Rs,Pn, OutR,WR,ACT |
Fun139 |
HSPWM |
|
|
HSPWM2 |
EN,Pw,Op,Hz,O_R, ACT,ERR |
Fun144 |
HSPWM2 |
|
|
ICA |
EN,D_R,Ps,Is,Fo,Ag,ACT,ERR,DN |
Fun137 |
ICA |
|
|
ICF |
EN,D_R,Ps,Is,Fo,Fd,ACT,ERR,DN |
Fun138 |
ICF |
|
|
MHSPO |
EN,PAU,ABT,Gp,SR,WR,ACT,ERR,DN |
Fun147 |
MHSPO |
|
|
MPARA |
EN,Ps,SR |
Fun141 |
MPARA |
|
|
MPG |
EN,Sc,Ps,Fo,Mr,WR,ACT |
Fun148 |
MPG |
|
|
PSCNV |
EN,Ps,D |
Fun143 |
PSCNV |
|
|
PSOFF |
EN,Ps |
Fun142 |
PSOFF |
|
|
INTDisable |
LB |
Fun146 |
DIS |
|
|
INTEnable |
LB |
Fun145 |
EN |
|
|
TARESUB |
EN,RST,ID,CH,SB, ERR |
Fun258 |
MODCONF |
|
|
TAREZEOFFSET |
EN,MD,ID,CH,WR,ERR |
Fun258 |
MOD |
|
|
MFSysCAMR |
EN,Md,D,ID,L,ACT,ERR,DN |
Fun191 |
MFSysCAMR |
|
|
MFSysCAMW |
EN,Md,D,ID,L,ACT,ERR,DN |
Fun192 |
MFSysCAMW |
|
|
MFSysInit |
EN,ACT,ERR,DN |
Fun187 |
MFSysInit |
|
|
MFSysRCPR |
EN,Md,D,Gp,ACT,ERR,DN |
Fun188 |
MFSysRCPR |
|
|
MFSysRCPW |
EN,MD,D,GP,ACT, ERR,DN |
Fun189 |
MFSysRCPW |
|
|
MFSysRstAlm |
EN,ACT,ERR,DN |
Fun185 |
MFSysRstAlm |
|
|
MFSysSetVirt |
EN,AX,ACT,ERR,DN |
Fun235 |
MFSysSetVirt |
|
|
MFSysStop |
EN,ACT,ERR,DN |
Fun177 |
MFSysStop |
|
|
MFChgTbPrm |
EN,GP,ID,N,D,ERR,DN |
Fun181 |
MFChgTbPrm |
|
|
MFFlowHalt |
EN,ID,ACT,ERR,DN |
Fun184 |
MFFlowHalt |
|
|
MFFlowPause |
EN,ID,ACT,ERR,DN |
Fun182 |
MFFlowPause |
|
|
MFFlowStart |
EN,ID,ACT,ERR,DN |
Fun176 |
MFFlowStart |
|
|
MFFlowStop |
EN,ID,ACT,ERR,DN |
Fun186 |
MFFlowStop |
|
|
MFMapTbPrm |
EN,GP,ID,N,D,ERR,DN |
Fun198 |
MFMapTbPrm |
|
|
MFHome |
EN,AX,ACT,ERR, DN |
Fun178 |
MFHome |
|
|
MFJog |
EN,D_R, AX, MD,ACT,ERR ,DN |
Fun180 |
MFJog |
|
|
MFPointMov |
EN,PT,AX,ACT,ERR,DN |
Fun179 |
MFPointMov |
|
|
MFAxCirMov |
EN,UPD,TAX,MD, DR,BF,D,EC,ACT,ERR,DN,UPD |
Fun239 |
MFAxCirMov |
|
|
MFAxLMov |
EN,UPD,TAX,MD, DR,BF,D,EC,ACT, ERR,DN,UPD |
Fun238 |
MFAxLMov |
|
|
MFAxMov MFAxMov_D |
EN,UPD_in,AX,MD,Ps,V_n,A,D,SA,SD,DR,BF,ACT,ERR,DN,UPD_out |
Fun197 |
MFAxMov |
|
|
MFGearMPG MFGearMPG_D |
EN,UPD_in,M,S,N,D,T,ACT,ERR,DN,UPD_out |
Fun193 |
MFGearMPG |
|
|
MFPathMov |
EN,ACT,UPD,AX1,AX2,AX3,PT,V,TA,TD,SA,SD,EC,ACT,ERR,DN,UPD |
Fun240 |
MFPathMov |
|
|
MFTorqCtl MFTorqCtl_D |
EN,UPD_in,AX,T,MX,ACT,ERR,DN, UPD_out |
Fun195 |
MFTorqCtl |
|
|
MFVelCtl MFVelCtl_D |
EN,UPD_in,AX,T,MX,ACT,ERR,DN, UPD_out |
Fun194 |
MFVelCtl |
|
1-17 Functions with multiple calling modes
|
ST function name |
Parameter |
Parameter description |
|
ToBCD ToBCD_D |
S,D |
S: The data being converted or its register number. D: The register number that stores the conversion result (BCD code) |
|
ToBIN ToBIN_D |
S,D |
S: The data being converted or its register number. D: The scratchpad number where the conversion result (BIN code) is stored. |
|
F_TRIG |
S,D |
S: The data being converted or its register number. D: The relay coil number where the derivative result is stored |
|
R_TRIG |
S,D |
S: The data being converted or its register number. D: The relay coil number where the derivative result is stored |
|
Timer |
EN,T,PV,IsTimeout |
Tn: The timer number, which is the stored accumulated timekeeping time (i.e. the current value CV). /b14> PV :(Preset Value) is the set value of the timer. |
|
Counter Counter_L |
Pulse,clr,C,PV,IsUp |
CN: The counter number, which is the accumulated count value (i.e. the current value CV). PV:(Preset Value) is the setting of the counter. |
|
ABS ABS_D |
D |
D: Take the register number of the absolute value |
|
CRC16 |
S,N,D |
MD:0, when calculating CRC, only the low group of the scratchpad is calculated, and the bytes of the scratchpad are not counted :1, reserved S: The starting register number of the CRC needs to be calculated N: The data length of the CRC needs to be calculated, and the unit is bytes D: The register number that stores the CRC calculation result, and the register D stores the Upper Byte register D of the CRC calculation result +1 Lower Byte S,N,D of the stored CRC resultThe operator can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
DIV |
Sa,Sb,D |
Sa: The dividend number or its scratchpad number. SB: The divisor or its register number. D: The( register number where the result (quotient and remainder) is stored. Sa,Sb,D can be combined with V,Z,P0~P9 for indirect addressing applications. |
|
FtoI FtoI_D |
S,D |
S: The starting number of the source register D: The register used by the register start number operator to store the result (integer) must be an even address, e.g. R8 is valid, R7 is not. /b110> The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing with |
|
FACOS_deg |
S,D |
S: Find the source value or the register number of the arcsine function value. /b11> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. /b17> D : The ) number of the register that holds the result (arcsine value). S and D can be combined with V, Z, P0~P9 for indirect addressing applications. |
|
FACOS_rad |
S,D |
|
|
FASIN_deg |
S,D |
S: Find the source value or the register number of the arcsine function value. /b11> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. /b17> D : The ) number of the register that holds the result (arcsine value). /b113> S and D can be combined with V, Z, P0~P9 for indirect addressing applications. |
|
FASIN_rad |
S,D |
|
|
FCOS |
S,D |
S: Find the source value or register number of the COS value. D : The number of the scratchpad where the result is stored. /b12> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FDIV |
Sa,Sb,D |
Sa: The dividend number or its scratchpad number. SB: The divisor or its register number. D: The register start number of the result (quotient) The register used by the operator must be an even address, e.g. R8 is legitimate, R7 /b110>It’s not legal. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FMUL |
Sa,Sb,D |
Sa: The multiplier or its scratchpad number. SB: Multiplier or its scratchpad number. D: The register start number of the result (product) The register used by the operator must be an even address, e.g. R8 is legitimate, R7 /b110>It’s not legal. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FSIN |
S,D |
S: The source value or scratchpad number for which the SIN value is found. D : The number of the register where the result is stored. /b11> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FSQR |
S,D |
S: Find the source value or scratchpad number of the square root. D : The register number that holds the result (square root value) /b15> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FTAN |
S,D |
S: The source value or scratchpad number of the TAN value. /b13> D : The number of the register where the result is stored. /b15> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
FZCP |
S,Su,S1,INZ,ERR |
S : ) The number of the register that holds the comparison data (floating-point number). SU: The upper limit value of the area or the upper limit value of the register number. SL: The lower limit value of the zone or the number of the lower limit value scratchpad. /b11> The register used by the operator must be an even address, e.g. R8 is valid and R7 is not. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
ItoF ItoF_D |
S,D |
S : The starting number of the source register D: The register start number of the result (floating-point) The register used by the operator must be an even address, e.g. R8 is valid, R7 /b110>It’s not legal. The S and D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
LCNV LCNV_D |
EN,Md,S,Ts,D,L |
Md: operation mode selection, 0~3 S: the start number of the source register to be converted TS: the start number of the start register of the conversion table D: The starting register number where the conversion result is stored L: The length to be converted, 1~64 |
|
MEAN MEAN_D |
S,N,D |
S: The starting number of the source register N: The number of registers to be averaged (N consecutive registers starting from S). D: The register number where the result (average) is stored S,N,D can be combined with V,Z,P0~P9 for indirect addressing applications |
|
MLC |
EN,XY,Rs,Sl,Tx,Ty,Tl,D,OVR |
Rs: Source data start register number Sl: The length of the source data to be converted, 1~64 Tx:X converts the table start register start number Ty:Y converts the start number of the table start register Tl: Conversion table length, 2~255 D: The starting register number where the conversion result is stored |
|
MUL |
Sa,Sb,D |
Sa: The multiplier or its scratchpad number. SB: Multiplier or its scratchpad number. D: The register number where the result (product) is stored. Sa, Sb, D can be combined with V, Z, P0~P9 for indirect addressing. |
|
SUM SUM_D |
S,N,D |
S: The starting number of the source register N: The number of registers to be summed (N consecutive registers starting from S). D: The register number where the result (sum) is stored S,N,D can be combined with V,Z,P0~P9 for indirect addressing applications |
|
BITRD BITRD_D |
S,N,OTB,ERR |
S : The data of the bit to be read or its register number N: Specifies that the Nth digit of data in the S data is read out S,N can be combined with V, Z, P0~P9 for indirect addressing applications |
|
BITWR BITWR_D |
INB,D,N,ERR |
D: The register number of the bit to be written N: Specifies that the state of the write bit INB is written to the Nth bit D in D, and N can be combined V, Z, P0~P9 for indirect addressing applications |
|
DBUF |
EN,ID,CH,D,DN |
ID: Extension module ID number (0~N). CH : Extended Module Channel Index ( 0 ~ N) D : The start register that holds the cache data |
|
ReadSDMem |
EN,INC,Bk,Os,Pr,L,D,ERR |
BK: SD card block number, 0~1 OS: the starting location of the partitioned data PR: Indicator scratchpad number L: Read data length 1~128 D: The start number of the register that stores the read data |
|
ReadWriteFileReg ReadWriteFileReg_D |
EN,R_W,INC,Sa,Sb,Pr,L |
SA: The starting register number of the scratchpad list SB: The starting number of the file register PR: Indicator scratchpad number L: The length of the list is 1~511 Sa can be combined with V, Z, P0~P9 for indirect addressing applications |
|
SWAP |
D |
D: The register number that performs byte data swapping D can be combined with V, Z, P0~P9 for indirect addressing applications |
|
WriteSDMem |
EN,INC,S,Bk,Os,Pr,L,WR,ACT,ERR,DN |
S: The number of the source from which the data is written BK: the block number of the SD card, 0~1 OS: the starting position of the partition data Pr: Indicator register number L: Write data length 1~128 WR: The starting number of the working register, which occupies a total of 2 registers S can be combined with V, Z, P0~P9 for indirect addressing applications |
|
ToASCII |
S,N,D |
S : The starting number of the source register N: The number of ASCII codes to be converted into hexadecimal values D: The start number of the register where the result (ASCII code) is stored S,N,D can be combined with V,Z,P0~P9 for indirect addressing applications |
|
ToBCD ToBCD_D |
S,D |
S: The data being converted or its register number. D: The register number that stores the conversion result (BCD code) S, D can be combined with V, Z, P0~P9 for indirect addressing applications. |
|
ToBIN ToBIN_D |
S,D |
S: The data being converted or its register number. D: The scratchpad number where the conversion result (BIN code) is stored. S,D can be combined with V,Z,P0~P9 for indirect addressing applications |
|
ToHEX |
S,N,D |
S : The starting number of the source register N: The number of hexadecimal values to be converted to ASCII codes D: The start number of the scratchpad where the result (hexadecimal value) is stored S,N,D can be combined with V,Z,P0~P9 for indirect addressing applications |
|
ToHMS |
S,D |
S: The number of seconds to be converted, the starting number of the data register D: The first number of the register stored in the transformation result (hours:minutes:seconds). |
|
ToSEC |
S,D |
S: The starting number of the time data register to be changed D: The starting number of the register where the result is stored |
|
BintoGray BintoGray_D |
S,D |
S : The starting number of the source register D: The start number of the scratchpad where the result (Gray code) is stored The S,D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
DECOD |
S,Ns,Nl,D,D,ERR |
S: The decoded source data register number (16 bits). NS: The start bit to be decoded in S NL: The length of the decoded value (1~8 bits) D : The starting number of the register (2~256 points=1~16 words) where the decoding result is stored S, NS, NL, D can be combined with V, Z, P0~P9 for indirect addressing |
|
ENCOD |
H_L,S,Ns,Nl,D,D_0,ERR |
S : The first digit of the encoded register NS: Specify one of the points in S as the starting point of the encoding NL: the number of single points of the encoding (2~256 points) D : The register number (1 word) S,NS,NL that holds the encoding result, D can be combined with V, Z, P0~P9 for interconnected addressing applications |
|
GraytoBin GraytoBin_D |
S,D |
S : The starting number of the source register D: The start number of the scratchpad where the result (Gray code) is stored The S,D operators can be combined with V, Z, P0~P9 indicators for indirect addressing applications |
|
PID PID_D |
AM,BUM,D_R,Ts, SR,O_R,PR,WR,CCERR,HAL,LAL |
Ts: The interval between PID operations SR : Programmable setpoint start register number, occupies a total of 8 registers OR: PID output register number PR: Parameter setting start register number, 7 registers occupied WR: The starting number of the working register required for this instruction occupies a total of 5 scratchpads, It cannot be reused elsewhere. |
|
PID2 |
EN,UPD,AM,D_R, ID,CH,SR,OutR,PR,WR,ERR |
ID: The number of the extension module used as the input signal CH : The channel number used as the input signal SR : Programmable setpoint start register number, occupies a total of 8 registers OR: PID output register number PR: Parameter setpoint start register number, 7 registers occupied in total WR: The working instantial memory start number required for this instruction occupies a total of 5 scratchpads, and cannot be reused elsewhere. |
|
TPCTL2 |
EN,UPD,A_M,D_R, ID,CH,SR,PR,OriR, WR,ERR,ALM |
ID: The number of the extension module used as the input signal CH: The channel number used as the input signal SR : Programmable start register PR : Gain setting start register OR: Output start register WR: Working Start Register |
|
IMDIO |
D,N |
D: The I /O number to be updated N: The number of I/O points to be updated |
|
SPD |
EN,S,TI,D,OVF |
S : To detect the pulse of velocity input point TI: Detection sampling time (in mS). D: The register number where the result is stored |
|
ACTimer_10MS ACTimer_10MS_D |
TIM,EN,CV,PV,TUP,NUP |
CV: The number of the register that holds the timed time (i.e. the current value). PV: A timer setting or a register number range operator that stores the set value WX WY WM WS TMR CTR HR IR OR SR ROR DR |
|
ACTimer_100MS ACTimer_100MS_D |
TIM,EN,CV,PV,TUP,NUP |
|
|
ACTimer_1S ACTimer_1S_D |
TIM,EN,CV,PV,TUP,NUP |
|
|
RSWDT |
There are no operators in this command |
|
|
WDT |
N |
N: The set time of the monitoring timer. /b11> Its value can only be 50, 60, 70… … 120, the unit is 10mS, that is, the set time range is (50~ 120)×10mS, that is, 0.5 seconds ~ 1.2 seconds |
|
HSCTR |
CN |
CN: Hardware high-speed counter number 0: HSC0 1: HSC1 2: HSC2 3: HSC3 4:HSC4 5:HSC5 6:HSC6 7:HSC7 |
|
HSCTW |
S,CN,D |
CN: Hardware high-speed counter number 0: HSC0 1: HSC1 2: HSC2 3: HSC3 4:HST4 2:HSC2 3:HSC3 4:HST4 D: Write object (0: for CV, 1: for PV) |
|
RAMP2 |
EN,Om,Ta,Td,Rt,Rc,WR,ACC,DEC |
OM: Maximum output setting; Set the range 0~65535 TA: Rise time from 0 to maximum output; The setting range is 0~65000, and the unit is MS TD: The fall time from the maximum output to 0 is set; The setting range is 0~65000, and the unit is MS RT: Target output setting scratchpad; Set the range 0~65535 RC: The current output register, which is used as a D/A output WR: The starting address of the working register, which occupies a total of 4 registers |
|
CLINK |
EN,PAU,ABT,Pt,MD,WR,ERR,DN |
Pt: Specify the port, 1, 2 MD: Communication mode selection (MD0~MD3). SR : Holds the start register of the communication program WR: The instruction operates the start register, which occupies a total of 8 registers, and other programs cannot be reused. |
|
CMCTL |
EN,PAU,ID,Pt,Ts, MD,WR,ERR |
ID: The number of the module used Pt: Specifies COMA/COMB (A= 0; B=1) TS: Communication Form Blocking Bit 1: Form 0, Bit 2: Form 1 ~ Bit 15: Form 15 Bit 16~Bit 31: Reserved, not usable MD: Setup Mode 0: RUN ONCE 1: RUN CYCLING 2: STOP WR: Store working status Bit0~Bit1: Table 0 state Bit2~Bit3: Table 1 state ~ Bit30~Bit31: Table 15 state (= 0:RUN_ONCE = 1:RUN_CYCLING = 2:STOP ) |
|
ModBUS |
EN,A_R,ABT,PT,SRWR,ACT,ERR,DN, |
PT: 1, 2, through this port,, the MODBUS RTU communication protocol is used for data transmission SR: Communicator start register (see example). WR: The instruction operation start register (see example), which occupies a total of 8 registers, and cannot be reused by other programs |
|
NCR |
NE,SR,MD,WR,ACT,ERR,DN |
SR: Table start register address. MD: Modbus TCP active communication (=1). WR: Working Register. |
|
BKCMP BKCMP_D |
Rs,Ts,L,D |
RS : the data being compared or its register number TS : The starting number of the upper and lower limit register blocks L: The number of groups of upper and lower limits D: The starting number of the relay where the comparison result is stored |
|
BT_M BT_M_D |
Ts,Td,L |
TS: The register number at the beginning of the source list TD: The register number at the beginning of the list of destinations L: The length of the list of sources and destinations TS, TD can be combined with V, Z, P0~P9 for indirect addressing applications |
|
QUEUE QUEUE_D |
InOut,IW,Qu,L,Pr,OW,EPT,FUL |
IW: The information or its register number that is squeezed into the list QU: The number of the starting register of the store L: The length of the storage column PR: Indicator scratchpad number OW: The number of the register that receives the data removed from the memory QU can be combined with V, Z, P0~P9 for indirect addressing applications |
|
T_Search T_Search_D |
FHD,DS,Rs,Ts,L,Pr,FND,END,ERR |
Rs: The source (sample) information sought or its scratchpad number TS: The register number at the beginning of the searched list L: the length of the list PR: Indicator, which is used to record the value of the location of the target Rs,Ts can be combined with V, Z, P0~P9 for indirect addressing applications |
|
SORT SORT_D |
AD,S,D,L |
S : The register number at the beginning of the source data to be sorted D: The registered number at the beginning of the sorted data L: The length of the sorted data |
|
STACK STACK_D |
InOut,IW,ST,L,Pr, OW,EPT,FUL |
IW: Stuffed data or its scratchpad number ST: The register number at the beginning of the stack L: The length of the stack PR: Indicator scratchpad number OW: The register number that receives the stack outgoing data ST can be combined with V, Z, P0~P9 for indirect addressing applications |
|
T_Compare T_Compare_D |
FHD,DS,Ta,Tb,L,Pr,FND,END,ERR |
TA: The starting number of the register of List A TB: The starting number of the register in List B L: The length of lists a and b PR: Indicator, which is used to record the value of the location of the target Ta,Tb can be combined with V, Z, P0~P9 for indirect addressing applications |
|
T_Fill T_Fill_D |
Rs,Td,L |
RS: The source information or its register number to be included in the list TD: The register number at the beginning of the list L : The length of the list RS, TD can be combined with V, Z, P0~P9 for indirect addressing applications |
|
ZoneWR |
Val,D,N |
D: The starting address of the region to be written or cleared N: The length of the area to be written or cleared: 1~511 D, N can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MAND |
Ma,Mb,Md,L |
MA: The starting register number of Source Matrix A MB: The register number at the beginning of Source Matrix B MD: The number of the scratchpad at the beginning of the matrix for which the results are stored L: The length of the matrix (Ma, Mb, and Md). Ma, Mb, Md can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MBCNT |
OnOff,Ms,L,D |
MS: The register number at the beginning of the matrix L : The length of the matrix D : The register number where the quantity result is stored MS can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MBRD |
EN,INC,CLR,Ms,L, Pr,OTB,END,ERR |
Ms: The scratchpad number at the beginning of the matrix L : The length of the matrix PR: Indicator register number Ms can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MBROT |
L_R,Ms,Md,L,OTB |
Ms : The register number at the beginning of the source matrix MD: The register number at the beginning of the destination matrix L: Matrix (Ms and Md) length MS, Md can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MBSHF |
INB,L_R,Ms,Md,L,OTB |
Ms : The register number at the beginning of the source matrix MD: The register number at the beginning of the destination matrix L: Matrix (Ms and Md) length Ms, Md can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MINV |
Ms,Md,L |
Ms : The register number at the beginning of the source matrix MD: The number of the scratchpad at the beginning of the matrix for which the result is stored L: The length of the matrix (Ms and Md). Ms,Md can be combined with V, Z, P0~P9 for indirect addressing applications |
|
MOR |
Ma,Mb,Md,L |
MA: The starting register number of Source Matrix A MB: The register number at the beginning of Source Matrix B MD: The number of the scratchpad at the beginning of the matrix for which the results are stored L: The length of the matrix (Ma, Mb, and Md). Ma, Mb, Md can be combined with V, Z, P0~P9 for indirect Addressing applications |
|
MXNR |
Ma,Mb,Md,L |
MA: The scratchpad number at the beginning of Source Matrix A MB: The register number at the beginning of Source Matrix B MD: The number of the scratchpad at the beginning of the matrix for which the result is stored L : the length of the matrix (Ma, Mb, Md). Ma, Mb, Md can be combined with V, Z, P0~P9 for indirect Addressing applications |
|
MXOR |
Ma,Mb,Md,L |
MA: The scratchpad number at the beginning of Source Matrix A MB: The register number at the beginning of Source Matrix B MD: The number of the scratchpad at the beginning of the matrix for which the result is stored L : the length of the matrix (Ma, Mb, Md). Ma, Mb, Md can be combined with V, Z, P0~P9 for indirect Addressing applications |
|
HSPSO |
EN,PAU,ABT,Ps,SR,WR,ACT,ERR,DN |
Ps : The first set of Pulse outputs (0~7). 0:Y0 & Y1 1:Y2 & Y3 2:Y4 & Y5 3:Y6 & Y7 4:Y8 & Y9 5:Y10 & Y11 6:Y12 & Y13 7:Y14 & Y15 SR: Locator program start register WR: The instruction operates the start register, which occupies a total of 7 registers, and other programs cannot be reused |
|
HSPWM |
EN,Pw,Op,Rs,Pn, OutR,WR,ACT |
PW : High-speed pulse-width modulation output point (0=Y0, 1=Y2, 2=Y4, 3=Y6, 4=Y8, 5=Y10, 6=Y12, 7=Y14) Op : Output polarity; 0=Output non-inverted 1=Output inverted Rs : Resolution; 0=1/100 (1%) 1=1/1000 (0.1%) Pn : Output frequency parameter setting (0~255). OR : PWM output width setting register 0~100 or 0~1000 WR : Instruction operation work register, other programs cannot be reused |
|
HSPWM2 |
EN,Pw,Op,Hz,O_R, ACT,ERR |
PW: Pulse width modulation output point (0=Y0, 1=Y2, 2=Y4, 3=Y6, 4=Y8, 5=Y10, 6=Y12, 7=Y14) Op: Output polarity (0=positive phase, 1=inverted phase) Hz: Output frequency (1~100000000 or 1~200000000, unit 0.001Hz) OR: Pulse output width (0~100, unit %) |
|
ICA |
EN,D_R,Ps,Is,Fo,Ag,ACT,ERR,DN |
Ps: Which group of Pulse output (0~7) 0: Y0 & Y1 1: Y2 & Y3 2: Y4 & Y5 3: Y6 & Y7 4: Y8 & Y9 5: Y10 & Y11 6: Y12 & Y13 7: Y14 & Y15 Ls: External input X point index number (0~15) Fo: Target working speed (1~100000 or 1~200000) Ag: Fixed angle during interruption (0~36000) |
|
ICF |
EN,D_R,Ps,Is,Fo,Fd,ACT,ERR,DN |
Ps: Which group of Pulse output (0~7) 0: Y0 & Y1 1: Y2 & Y3 2: Y4 & Y5 3: Y6 & Y7 4: Y8 & Y9 5: Y10 & Y11 6: Y12 & Y13 7: Y14 & Y15 Ls: External input X point index number (0~15) Fo: Target working speed (1~100000 or 1~200000) Fd: pulse movement amount output after interrupting capture |
|
MHSPO |
EN,PAU,ABT,Gp,SR,WR,ACT,ERR,DN |
Gp: which group (0~1) SR: Positioning program start register WR: Instruction operation starting register, occupying 9 registers in total, cannot be reused by other programs |
|
MPARA |
EN,Ps,SR |
Ps: Which group of Pulse Output (0~3) SR: Parameter table starting register, a total of 18 parameters, occupying 24 temporary registers |
|
MPG |
EN,Sc,Ps,Fo,Mr,WR,ACT |
Sc: Specify the source of the rocker to take over the high-speed counter; 0~7 Ps: Specify the pulse wave output axis of the reaction hand wheel; 0~3 Fo: Output frequency setting register (2 registers) Mr: Ratio setting register (2 registers) Mr+0: Multiplicand (Fa) Mr+1: Multiplier dividend (Fb) WR: Starting address of working register, occupying 4 registers in total. Output pulse number = (hand wheel input pulse number × Fa)/Fb * PLC OS V4.60 (inclusive) and later supports this command |
|
PSCNV |
EN,Ps,D |
Ps: 0~3; Convert the pulse wave position (PS) of the group into mm (Deg, Inch, PS) with the same unit as the set value to display the current position. D: The register that stores the current position after conversion. A total of two registers are needed; for example, D10 represents the two registers D10 (Low Word) and D11 (High Word). |
|
PSOFF |
EN,Ps |
Ps: 0~3 forces the Pulse Output group to stop outputting. |
|
INTDisable |
LB |
LBL: The name of the interrupt mark that prohibits external input or peripheral action. |
|
INTEnable |
LB |
LBL: Allows external input or peripheral tag name to interrupt the action. |
|
TARESUB |
EN,RST,ID,CH,SB, ERR |
ID: expansion module ID number (0 ~ N) CH: channel index (0 ~ N) SB: 32BIT value of the tare weight to be deducted |
|
TAREZEOFFSET |
EN,MD,ID,CH,WR,ERR |
|
|
MFSysCAMR |
EN,Md,D,ID,L,ACT,ERR,DN |
Read E-Cam data Route 1: From PLC Md: 0 D: The initial address of the PLC register after the E-Cam data is read ID: E-Cam number L: E-Cam resolution Route 2: From FATEK SD card Md: 1 D: FATEK SD card E-Cam data’s file number ID: E-Cam number L: E-Cam resolution |
|
MFSysCAMW |
EN,Md,D,ID,L,ACT,ERR,DN |
Write E-Cam data Route 1: From PLC Md: 0 D: The initial address of the written E-Cam data in the PLC register ID: E-Cam number L: E-Cam resolution Route 2: From FATEK SD card Md: 1 D: FATEK SD card E-Cam data’s file number ID: E-Cam number L: E-Cam resolution |
|
MFSysInit |
EN,ACT,ERR,DN |
Enable the Motion function / open the driver connection |
|
MFSysRCPR |
EN,Md,D,Gp,ACT,ERR,DN |
Read the formula according to the content set by the sports formula Route 1: From PLC Md: 0 D: meaningless in mode 0 Gp: Read all set recipes = 0, Read first set recipe = 1, and so on Route 2: From FATEK SD card Md: 1 D: FATEK SD card recipe file number Gp: Read all set recipes = 0, Read first set recipe = 1, and so on |
|
MFSysRCPW |
EN,MD,D,GP,ACT, ERR,DN |
Write the formula according to the content set by the sports formula Route 1: From PLC Md: 0 D: meaningless in mode 0 Gp: Write all set recipes = 0, write first set recipe = 1, and so on Route 2: From FATEK SD card Md: 1 D: FATEK SD card recipe file number Gp: Write all set recipes = 0, write first set recipe = 1, and so on |
|
MFSysRstAlm |
EN,ACT,ERR,DN |
Remade motion control bug |
|
MFSysSetVirt |
EN,AX,ACT,ERR,DN |
Translate Real axis to virtual axis It is used when the physical shaft is sent for repair or the amount of shafts of different project models is reduced AX: axis number |
|
MFSysStop |
EN,ACT,ERR,DN |
Stop the Motion function / close the drive connection |
|
MFChgTbPrm |
EN,GP,ID,N,D,ERR,DN |
single data mapping TM: form type PN: form number S: project PV: mapped value |
|
MFFlowHalt |
EN,ID,ACT,ERR,DN |
Immediately suspend the Motion Flow ID: Motion Flow number |
|
MFFlowPause |
EN,ID,ACT,ERR,DN |
After completing the current action block, pause the Motion Flow ID: Motion Flow number |
|
MFFlowStart |
EN,ID,ACT,ERR,DN |
Start Motion Flow ID: Motion Flow number |
|
MFFlowStop |
EN,ID,ACT,ERR,DN |
Abort Motion Flow ID: Motion Flow number |
|
MFMapTbPrm |
EN,GP,ID,N,D,ERR,DN |
Map data according to the motion parameter mapping table Gp: Mapping table page number N: Starting item number L: amount of mapped items |
|
MFHome |
EN,AX,ACT,ERR, DN |
Execute axis homing mode AX: axis number |
|
MFJog |
EN,D_R, AX, MD,ACT,ERR ,DN |
Execute Jog mode AX: axis number MD: Continuous motion at start speed (0), jog at start speed (1), continuous motion at JOG speed (2), jog at JOG speed (3) D/R: positive direction (ON) / negative direction (OFF)D/R:Positive direction (ON) / Negative direction (OFF) |
|
MFPointMov |
EN,PT,AX,ACT,ERR,DN |
Execution point table positioning mode Pt: point number AX: Axis number |
|
MFAxCirMov |
EN,UPD,TAX,MD, DR,BF,D,EC,ACT,ERR,DN,UPD |
Total number of axes (TAX): Mode (MD): 0: absolute, 1: relative Direction (DR): 1: Forward, 2: Reverse Continuous mode (BF): 0 = execute current instruction immediately 1 = wait for the previous instruction to complete 2 = Select lower speed continuous 3 = Select the previous command speed 4 = Select current command speed 5 = Select higher speed continuous Click Data (D): scratchpad starting position Error code (EC): scratchpad storage location |
|
MFAxLMov |
EN,UPD,TAX,MD, DR,BF,D,EC,ACT, ERR,DN,UPD |
|
|
MFAxMov MFAxMov_D |
EN,UPD_in,AX,MD,Ps,V_n,A,D,SA,SD,DR,BF,ACT,ERR,DN,UPD_out |
Execute single-axis positioning mode S: spindle number MD: Absolute coordinates (0) / Relative coordinates (1) / Infinite distance mode (2) Ps: target coordinates V: Maximum linear speed A: Maximum acceleration D: Maximum deceleration SA: Acceleration section S curve proportion (unit: 0.1%) SD: S curve ratio of deceleration section (unit: 0.1%) DR: Positive direction (1) / Negative direction (2) BF: continuous point mode |
|
MFGearMPG MFGearMPG_D |
EN,UPD_in,M,S,N,D,T,ACT,ERR,DN,UPD_out |
M: (Spindle) 1~16: axis number 100: Gray code (X8~15) 101~108: HSC0~7 S: (slave axis) 1~16: axis number N: (conversion numerator) Integer, including decimal point from axis D: (conversion denominator) Positive integer including main axis decimal point T: (smoothing time) positive integer Unit: ms |
|
MFPathMov |
EN,ACT,UPD,AX1,AX2,AX3,PT,V,TA,TD,SA,SD,EC,ACT,ERR,DN,UPD |
AX1: Axis 1 AX2: Axis 2 AX3: Axis 3 PT: path number V: Vel positive integer Includes spindle decimal point TA, TD: acceleration time Positive integer (ms) SA, SD: (S proportion %) 0.0% ~ 100.0% Unit: 0.1% EC: register storage location |
|
MFTorqCtl MFTorqCtl_D |
EN,UPD_in,AX,T,MX,ACT,ERR,DN, UPD_out |
AX: 1~16: axis number T: Unit: 0.1% MX: Maximum speed |
|
MFVelCtl MFVelCtl_D |
EN,UPD_in,AX,T,MX,ACT,ERR,DN, UPD_out |
AX: 1~16: axis number V: Unit: See the drive MX: Maximum torque |